Hydronic High-Wall-Fan Coil Units

42WH
Nominal cooling capacity 1.4-2.1 kW
Nominal heating capacity 1.9-3.2 kW

These elegant hydronic high-wall units complete the Carrier 1 After a power failure the unit will restart automatically with-
range of water-cooled indoor units. They are available with a out any change in user settings.
standard or fully featured back panel, depending on the appli- 1 42WH units are extremely simple to install and to maintain.
cation needs, and can be used in conjunction with every other For routine servicing they are easily accessible from one or
indoor terminal. both sides, and if needed, one person can service the unit in
The 42WH units combine stylish design and clear lines with less than 10 minutes.
optimum comfort and performance. 1 42WH units can be matched to any water chiller from 4 to
42WH units are available as cooling only models (42WHC) 100 kW to suit your individual application requirements.
and with electric heaters (42WHE).

Features
1 The units are ideal for hotels, but also suitable for a wide
range of other commercial and residential applications.
1 The new hydronic high-wall unit is designed to fit neatly on
any appropriate wall, above the occupants normal eye level.
This frees valuable floor space.
1 The standard version has extensions to cover the pipes.
1 The tangential fan brings new air to the ambient air very
quietly and unobtrusively. This means optimum comfort can
be achieved quickly and easily.
1 In the fully-featured version three-way valves are supplied as
standard.
1 The 42WH unit offers automatic temperature control. This is
the only model in its class to include cold draft prevention as
a standard feature. By automatically controlling the fan in
response to changes in the water temperature, the hydronic
high-wall units help create an ideal environment, anywhere
from small bedrooms to large reception areas, from shops to
office blocks. Fully-featured back panel
Physical and electrical data
Model 42WHC 016 42WHE 016 42WHC 020 42WHE 020 42WHC 028 42WHE 028
Total cooling capacity kW 1.43 1.43 1.65 1.65 2.10 2.10
Sensible cooling capacity kW 1.08 1.08 1.35 1.35 1.95 1.95
Water flow rate (cooling) l/s 0.068 0.068 0.079 0.079 0.100 0.100
Water pressure drop (cooling) kPa 14/22* 14/22* 19/30* 19/30* 34/50* 34/50*
Heating capacity kW 1.94 1.94 2.30 2.30 3.20 3.20
Electric heaters W - 500 - 1000 - 1000
Air flow rate (low/medium/high) l/s 47/59/69 47/59/69 72/81/86 72/81/86 111/123/131 111/123/131
Power input W 19 19 27 27 28 28
Current drawn A 0.08 0.08 0.12 0.12 0.12 0.12
Weight, unit kg 14.5 14.5 14.5 14.5 15.0 15.0
Weight, fully-featured back panel with valves kg 5 5 5 5 5.5 5.5
Weight, standard back panel kg 4.5 4.5 4.5 4.5 4.5 4.5
Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50
The above data refers to Eurovent conditions.
Cooling conditions: 27C db/19C wb air temperature, 7C/12C entering and leaving water temperature at high fan speed
Heating conditions: 20C air temperature, 50C entering water temperature, same water flow rate as in cooling, at high fan speed.

* Values with valves installed.

Unit dimensions, mm Fully featured back panel


42WH A B C D* 42WH A
016 800 290 190 45 016-020 282
020 800 290 190 45 028 320.5
028 800 337 215 45
* Dimension D refers to the fully-featured back panel, and basic back panel only.
For the standard back panel please refer to the appropriate drawings.

Standard back panel


Offered with detachable sides to allow water connections to
enter from left or right-hand side.
Basic back panel
Same as fully featured back panel, but without valves, water
connections only from the rear to fit perfectly behind the
unit.

42WH A
016-020 282
028 320.5

All dimensions are in mm.


Example of side connections Clearances, mm
with standard back panel
 

 

Water connections
All units 3/8" gas male
Outside connection diameter (inch), standard panel without valves 3/8" gas male
Inside connection diameter (inch), fully-featured panel with valves 3/8" gas female
Outside connection diameter (inch), fully-featured panel with valves 3/8" gas male
Cooling capacity, two-pipe coil (with fan at high speed)
Entering water Water temperature Entering air 42WH 016 42WH 020 42WH 028
temperature C rise K temperature C Total Sensible Total Sensible Total Sensible
wb db kW kW kW kW kW kW
6 3 15 21 1.09 0.96 1.28 1.09 1.66 1.53
6 5 15 21 0.76 0.76 0.94 0.92 1.08 1.08
6 7 15 21 0.54 0.54 0.74 0.74 0.78 0.78
6 9 15 21 0.45 0.45 0.57 0.57 0.63 0.63
7 3 15 21 0.95 0.88 1.09 1.01 1.46 1.41
7 5 15 21 0.67 0.67 0.84 0.84 0.94 0.94
7 7 15 21 0.48 0.48 0.65 0.65 0.69 0.69
7 9 15 21 0.39 0.39 0.49 0.49 0.54 0.54
9 3 15 21 0.74 0.74 0.84 0.84 1.15 1.15
9 5 15 21 0.50 0.50 0.65 0.65 0.68 0.68
9 7 15 21 0.37 0.37 0.47 0.47 0.52 0.52
9 9 15 21 0.27 0.27 0.31 0.31 0.37 0.37
11 3 15 21 0.57 0.57 0.66 0.66 0.86 0.86
11 5 15 21 0.35 0.35 0.47 0.47 0.49 0.49
11 7 15 21 0.25 0.25 0.30 0.30 0.34 0.34
6 3 17 23 1.47 1.09 1.75 1.26 2.24 1.75
6 5 17 23 1.03 0.89 1.34 1.08 1.48 1.37
6 7 17 23 0.69 0.69 0.97 0.91 1.05 1.05
6 9 17 23 0.56 0.56 0.74 0.74 0.80 0.80
7 3 17 23 1.29 1.01 1.56 1.17 1.97 1.63
7 7 17 23 0.61 0.61 0.84 0.83 0.87 0.87
7 9 17 23 0.51 0.51 0.65 0.65 0.71 0.71
9 3 17 23 1.00 0.88 1.15 1.00 1.52 1.41
9 5 17 23 0.69 0.69 0.84 0.83 0.97 0.97
9 7 17 23 0.48 0.48 0.65 0.65 0.69 0.69
9 9 17 23 0.39 0.39 0.49 0.49 0.54 0.54
11 3 17 23 0.74 0.74 0.84 0.84 1.16 1.16
11 5 17 23 0.51 0.51 0.65 0.65 0.70 0.70
11 7 17 23 0.37 0.37 0.47 0.47 0.52 0.52
11 9 17 23 0.27 0.27 0.31 0.31 0.37 0.37
13 3 17 23 0.57 0.57 0.65 0.65 0.87 0.87
13 5 17 23 0.35 0.35 0.47 0.47 0.49 0.49
13 7 17 23 0.25 0.25 0.30 0.30 0.34 0.34
6 3 19 25 1.94 1.24 2.26 1.42 2.98 1.99
6 5 19 25 1.40 1.02 1.86 1.25 2.01 1.59
6 7 19 25 0.96 0.83 1.41 1.07 1.25 1.19
6 9 19 25 0.68 0.67 1.00 0.90 0.98 0.98
7 3 19 25 1.76 1.17 2.07 1.33 2.69 1.87
7 5 19 25 1.23 0.95 1.65 1.16 1.78 1.49
7 7 19 25 0.83 0.76 1.20 0.98 1.10 1.10
7 9 19 25 0.62 0.62 0.85 0.82 0.89 0.89
9 3 19 25 1.39 1.01 1.66 1.17 2.09 1.63
9 5 19 25 0.95 0.82 1.22 0.99 1.35 1.27
9 7 19 25 0.63 0.63 0.86 0.83 0.87 0.87
9 9 19 25 0.51 0.51 0.65 0.65 0.71 0.71
11 3 19 25 1.04 0.87 1.23 1.00 1.59 1.40
11 5 19 25 0.70 0.70 0.86 0.83 1.00 1.00
11 7 19 25 0.48 0.48 0.65 0.65 0.69 0.69
11 9 19 25 0.39 0.39 0.48 0.48 0.54 0.54
13 3 19 25 0.76 0.74 0.84 0.83 1.17 1.17
13 5 19 25 0.53 0.53 0.65 0.65 0.72 0.72
13 7 19 25 0.37 0.37 0.47 0.47 0.52 0.52
13 9 19 25 0.27 0.27 0.31 0.31 0.37 0.37
6 3 19 27 1.93 1.41 2.25 1.60 2.97 2.27
6 5 19 27 1.47 1.21 1.85 1.43 2.20 1.92
6 7 19 27 1.10 1.02 1.43 1.25 1.52 1.52
6 9 19 27 0.82 0.82 1.12 1.09 1.16 1.16
7 3 19 27 1.75 1.33 2.06 1.51 2.70 2.16
7 5 19 27 1.43 1.08 1.65 1.35 2.10 1.95
7 7 19 27 0.98 0.96 1.26 1.18 1.40 1.40
7 9 19 27 0.75 0.75 1.01 1.01 1.07 1.07
9 3 19 27 1.42 1.19 1.65 1.35 2.22 1.94
9 5 19 27 1.08 1.02 1.26 1.18 1.60 1.59
9 7 19 27 0.82 0.82 1.01 1.01 1.14 1.14
9 9 19 27 0.62 0.62 0.83 0.83 0.89 0.89
11 3 19 27 1.14 1.06 1.25 1.18 1.78 1.72
11 5 19 27 0.88 0.88 1.02 1.02 1.33 1.33
11 7 19 27 0.65 0.65 0.84 0.84 0.88 0.88
11 9 19 27 0.51 0.51 0.65 0.65 0.71 0.71
13 3 19 27 0.92 0.92 1.01 1.01 1.47 1.47
13 5 19 27 0.71 0.71 0.84 0.84 1.03 1.03
13 7 19 27 0.49 0.49 0.65 0.65 0.69 0.69
13 9 19 27 0.39 0.39 0.48 0.48 0.54 0.54

Eurovent conditions

Note: The maximum operating water flow rate is 0.219 l/s (790 l/h) for size 016-020 and 0.365 l/s (1315 l/h) for size 028.
Cooling capacity, two-pipe coil (with fan at high speed)
Entering water Water temperature Entering air 42WH 016 42WH 020 42WH 028
temperature C rise K temperature C Total Sensible Total Sensible Total Sensible
wb db kW kW kW kW kW kW
6 5 21 29 1.94 1.35 2.40 1.59 2.83 2.13
6 7 21 29 1.43 1.14 1.96 1.41 2.02 1.77
6 9 21 29 1.04 0.96 1.51 1.24 1.39 1.39
7 3 21 29 2.24 1.47 2.60 1.67 3.48 2.38
7 5 21 29 1.74 1.27 2.20 1.51 2.56 2.02
7 7 21 29 1.29 1.09 1.74 1.33 1.82 1.66
7 9 21 29 0.92 0.90 1.32 1.16 1.28 1.28
9 3 21 29 1.87 1.32 2.19 1.50 2.87 2.14
9 5 21 29 1.40 1.14 1.76 1.34 2.09 1.81
9 7 21 29 1.03 0.96 1.32 1.17 1.44 1.43
9 9 21 29 0.76 0.76 1.02 1.01 1.07 1.07
11 3 21 29 1.49 1.18 1.76 1.34 2.31 1.92
11 5 21 29 1.13 1.01 1.32 1.17 1.66 1.59
11 7 21 29 0.83 0.83 1.02 1.01 1.17 1.17
11 9 21 29 0.62 0.62 0.833 0.83 0.89 0.89
13 3 21 29 1.19 1.05 1.320 1.17 1.85 1.71
13 5 21 29 0.89 0.89 1.020 1.01 1.35 1.35
13 7 21 29 0.66 0.66 0.835 0.84 0.91 0.91
13 9 21 29 0.51 0.51 0.651 0.65 0.71 0.71
6 5 23 31 2.49 1.50 2.980 1.74 3.72 2.37
6 7 23 31 1.89 1.27 2.560 1.58 2.62 1.97
6 9 23 31 1.37 1.08 2.090 1.40 1.81 1.60
7 5 23 31 2.30 1.43 2.770 1.66 3.41 2.26
7 7 23 31 1.68 1.20 2.340 1.49 2.38 1.87
7 9 23 31 1.24 1.03 1.850 1.32 1.62 1.50
9 5 23 31 1.90 1.28 2.350 1.50 2.75 2.02
9 7 23 31 1.37 1.08 1.880 1.33 1.93 1.68
9 9 23 31 0.98 0.91 1.390 1.16 1.31 1.31
11 3 23 31 2.01 1.32 2.340 1.49 3.07 2.13
11 5 23 31 1.48 1.13 1.890 1.33 2.21 1.81
11 7 23 31 1.09 0.97 1.400 1.16 1.50 1.45
11 9 23 31 0.78 0.78 1.050 1.00 1.08 1.08
13 3 23 31 1.59 1.17 1.880 1.33 2.42 1.90
13 5 23 31 1.18 1.01 1.410 1.17 1.74 1.60
13 7 23 31 0.85 0.84 1.040 1.01 1.20 1.20
13 9 23 31 0.63 0.63 0.834 0.83 0.89 0.89

Eurovent conditions

Note: The maximum operating water flow rate is 0.219 l/s (790 l/h) for size 016-020 and 0.365 l/s (1315 l/h) for size 028.

Heating capacity, two-pipe


Correction factors
42WH Capacity Fan speed coil (with fan at high speed)
High Medium Low Water flow rate Available temp. 42WHE 016 42WHE 020 42WHE 028
016 Total 1 0.90 0.70 l/h l/s difference, K kW kW kW
Sensible 1 0.89 0.69 100 0.03 20 0.98 1.09 1.16
020 Total 1 0.93 0.81 150 0.04 20 1.17 1.31 1.50
Sensible 1 0.93 0.80 230 0.06 20 1.33 1.50 1.85
283 0.08 20 1.39 1.57 2.01
028 Total 1 0.97 0.86
342 0.10 20 1.44 1.62 2.13
Sensible 1 0.97 0.86
400 0.11 20 1.47 1.65 2.21
Note: These factors should be considered mean values. For more accurate sizing please use 600 0.17 20 1.54 1.73 2.41
the ECAT software.
800 0.22 20 1.57 1.76 2.51
1200 0.33 20 1.61 1.79 2.63
100 0.03 30 1.51 1.63 1.79
150 0.04 30 1.79 1.97 2.33
230 0.06 30 2.00 2.24 2.84
283 0.08 30 2.11 2.30 3.06
342 0.10 30 2.17 2.42 3.20
400 0.11 30 2.22 2.48 3.37
600 0.17 30 2.32 2.58 3.65
800 0.22 30 2.37 2.64 3.80
1200 0.33 30 2.43 2.69 3.97
150 0.04 40 2.43 2.62 3.16
230 0.06 40 2.72 2.99 3.86
283 0.08 40 2.83 3.12 4.13
342 0.10 40 2.92 3.22 4.36
400 0.11 40 2.99 3.30 4.53
600 0.17 40 3.11 3.44 4.90
800 0.22 40 3.18 3.52 5.10
1200 0.33 40 3.25 3.59 5.32
230 0.06 50 3.47 3.83 4.87
283 0.08 50 3.62 4.00 5.24
342 0.10 50 3.74 4.14 5.54
400 0.11 50 3.82 4.24 5.77
600 0.17 50 3.99 4.43 6.26
800 0.22 50 4.08 4.52 6.53
1200 0.33 50 4.18 4.62 6.82
Available temperature difference = entering hot water temperature minus entering air dry bulb
temperature.
Maximum operating temperature 60C, maximum operating pressure 14 bar.
Air throw (cooling mode), m Operating limits
42WH 016 020 028 Water circuit
High speed 3.2 4.0 5.0 Maximum water-side pressure 1400 kPa
Medium speed 2.7 3.8 4.7 Minimum entering water temperature +6C
Low speed 2.2 3.3 4.2 Maximum entering water temperature +60C
Maximum entering water temperature with electric heaters +45C
1. With louvres adjusted in cooling position.
2. The air throw is defined as the distance at which the air flow speed falls to 0.2 m/s. Room air
3. The values are to be considered as indicative, as they may vary according to the type of Minimum temperature 5C*
ceiling, room dimensions and even the furniture. Maximum temperature 32C
Power supply
Nominal single-phase voltage 230 V, 50 Hz

Coil water content Operating voltage limits 198 V-264 V


* If the room temperature can go down to 0C, it is advisable to empty the water circuit to avoid
damage caused by ice.
42WH 016 020 028
Water content, l 0.6 0.6 0.7

Electrical data
(units with heaters)
42WH 016 020 028
Current A 2.3 4.56 4.56
Power input W 519 1027 1028
Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50

Sound levels
42WH Lw(A) Lp(A) NR
High speed Medium speed Low speed High speed Medium speed Low speed High speed Medium speed Low speed
016 40 35 30 31 26 21 27 22 17
020 44 42 38 35 33 29 31 30 24
028 49 47 44 40 38 35 37 35 32
Sound pressure levels in dB(A) and noise ratings NR are for a ceiling-installed unit and measured in a room with a volume of 100 m3 and 0.5 seconds reverberation time.

Lp(A) - Sound pressure level, dB(A)


Lw(A) - Sound power level, dB(A)
NR - Noise rating, dB(A)
Pressure drops
3-way valve assembly in bypass condition

10

Bypass
kPa

0,1
100 (0.03) 1000 (0.28) 10000 (2.78)
l/h (l/s)

3-way valve assembly in open condition

100

3-way valve +
flexible pipes
kPa

10

1
100 (0.03) 1000 (0.28) 10000 (2.78)
l/h (l/s)

Coil

1000

100
kPa

Size 028
Sizes 016, 020

10

1
100 (0.03) 1000 (0.28) 10000 (2.78)
l/h (l/s)
Manufactured by: Carrier SpA, Villasanta, Italy.
Order No. 14215-20, 09.2003. Supersedes order No. New. Printed on Totally Chlorine Free Paper.
Manufacturer reserves the right to change any product specifications without notice. Printed in the Netherlands.