1.00 EARTHWORK

Earth work in excavation by mechanical means (Hydraulic excavator) /


manual means in foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift up to 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m. All
kinds of soil

1.10

Earth work in excavation by mechanical means (Hydraulic excavator) /


manual means in foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift up to 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m. All
kinds of soil

1.20

Filling available excavated earth (excluding rock) in trenches,


plinth,sides of foundations etc. in layers not exceeding 20cm in
depth,consolidating each deposited layer by ramming and watering,
leadup to 50 m and lift upto 1.5 m.
1.30
TOTAL EXCAVATION - TOTAL CONCRETE

Supplying and filling in plinth with Jamuna sand under floors, including
watering, ramming, consolidating and dressing complete.
1.40
AREA OF PLINTH BEAM = TOTAL CARPET AREA - TOTAL VOLUME OF RCC
COLUMNS
2.00 CONCRETE

1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40


mm nominal size) Providing and laying in position cement concrete of
specified grade excluding
the cost of centering and shuttering - All work up to plinth level
2.10
FOOTINGS
Providing and laying in position machine batched and machine mixed
design
mix M-25 grade cement concrete for reinforced cement concrete work,
using cement content as per approved design mix, including pumping of
concrete to site of laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in recommended
proportions as per IS: 9103 to accelerate, retard setting of concrete,
improve
workability without impairing strength and durability as per direction of
Engineer-in-charge.

2.20
Upto plinth level
FOOTINGS
CUBOID
TRAPEZOIDAL
PART COLUMN
Above Plinth Level
BEAM
COLUMN
SLAB
Centering and shuttering including strutting, propping etc.
2.30
FOUNDATION
FOOTING
ROOF - (Staircase + Shaft)
BEAMS
COLUMNS
STAIRS(INCLUDING LANDING)
3.00 BRICKWORK

Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level
3.10
230 mm WALL ON GROUND FLOOR
230 mm WALL ON FIRST FLOOR
230 mm WALL ON SECOND FLOOR
Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor V
3.20 level.
115 mm Wall on Ground Floor
115 mm Wall on First Floor
115 mm Wall on Second Floor
4.00 FINISHING
12 mm cement plaster finished with a floating coat of neat cement of
4.10 mix
1:3 (1 cement: 3 fine sand)
EXTERIOR PLASTER OF WHOLE BUILDING
BALCONY (BALCONY ROOF + 3 SIDES)
INTERIOR PLASTER
CEILING PLASTER

INTERIOR BEAM SIDE PLASTER EXCLUDING BEAM BOTTOM

GROUND FLOOR INT PLASTERWALLS INCLUDING COLUMNS


1ST FLOOR INT PLASTER WALLS + COLUMNS
2ND FLOOR INT PLASTER WALLS + COLUMNS
TOTAL INTERIOR PLASTER ON ALL FLOORS WALLS ONLY
CEILING PLASTER ON ALL FLOORS
TOTAL INTERIOR PLASTER ON WALLS AND CEILING ON ALL FLOORS(A +B)

Wall painting with acrylic emulsion paint, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre, of approved brand
andmanufacture, including applying additional coats wherever required,
to achieve even shade and colour.
4.20
EXTERIOR PAINT
INTERIOR PAINT

Crazy marble stone flooring, including filling the gaps with light shade
pigment with white cement marble powder mixture (3 parts of white
cement: 1 part of marble powder) by weight in proportion of 4:7 (4
cement marble powder mix : 7 white, black or white and black marble
chips of sizes from 1 mm to 4 mm nominal size by volume), with under
layer 25 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 12.5 mm nominal size), including rubbing,
polishing and cement slurry etc. complete

4.30
SKIRTING ON GROUND FLOOR
SKIRTING ON FIRST FLOOR
SKIRTING ON SECOND FLOOR
TOTAL = FLOORING + SKIRTING ON ALL FLOORS
Melamine polishing on wood work only on door shutters
4.40
DOORS ON GROUND FLOOR
DOORS ON FIRST FLOOR

DOORS ON SECOND FLOOR

TOTAL AREA OF POLISHING(BOTH SIDES)

Providing and fixing false ceiling with 12 mm thick plain/ semi


perforated or with design ceiling tiles of BWP type phenol formaldehyde
synthetic resin bonded pressed particle board conforming to IS:3087,
finished with a coat of aluminium primer on both sides & edges,
including two coats of
synthetic enamel paint of approved quality on exposed face, fixed to a
grid made out of anodised aluminium (with 15 micron anodic coating)
Tsections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5
mm fixed to main runners placed 600 mm centre to centre both ways so
as to form a grid of 600 mm square. The frame work shall be suspended
from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof
slab by means of ceiling cleats and dash fastener. The suspenders shall
be placed 600 x 1200 mm centre to centre including fixing to the frame
with C.P brass screws and applying a priming coat of zinc chromate
yellow primer (aluminium frame work shall be paid separately).

4.50

Tile work in skirting, risers of steps and dado up to 2 m height over 12


mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and
jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in
white cement mixed with pigment of matching shade complete.
4.60
DADOING ONLY IN BATH AREA

Providing and laying integral cement based water proofing treatment


including preparation of surface as required for treatment of roofs,
balconies, terraces etc
4.70

WATERPROOFING IN SUNKEN SLAB IN BATH AREA (SUNKEN AREA +


AREA OF BATHROOM)
WATERPROOFING ON TERRACE FLOOR (FLOOR AREA INSIDE PARAPET -
(STAIRCASE WELL + SHAFT AREA))

WATERPROOFING ON BALCONY

TOTAL WATERPROOFING AREA

5.00 WOODWORK

Providing wood work in frames of doors, windows, clerestory windows


and other frames, wrought framed and fixed in position with hold fast
lugs or with dash fasteners of required dia & length ( hold fast lugs or
dash fastener shall be paid for separately).
5.10
SAL WOOD
DOOR FRAMES ON GROUND FLOOR

DOOR FRAMES ON FIRST FLOOR

DOOR FRAMES ON SECOND FLOOR

TOTAL VOLUME OF FRAMES

Providing and fixing panelled or panelled and glazed shutters for doors,
windows and clerestory windows, including ISI marked M.S. pressed
butt hinges bright finished of required size with necessary screws,
excluding panelling which will be paid for separately, all complete as per
direction of Engineer-in-charge.
5.20
Second class teak wood
DOORS ON GROUND FLOOR

DOORS ON FIRST FLOOR

DOORS ON SECOND FLOOR

TOTAL AREA OF SHUTTERS


Providing and Fixing factory made uPVC white colour casement/sliding
window / door, made of extruded profiles. Profiles of frames and sash
will be mitered cut and fusion welded at all corners, including drilling of
holes for fixing hardware and drainage of water etc., making
arrangement for
fixing of hardware, EPDM gasket, 1.2 0.2 mm thick galvanised steel
profile to be inserted in required profile, frame will be fixed to the wall
with 8 mm x 100 mm long fasteners, all complete as per direction of
Engineerin-
charge. (Glazing, hardware hinges and fitting etc. to be paid separately.)

5.30
Casement Window (Outward/Inward opening) with hinge System
WINDOWS ON G
NOS LENGTH(m) BREADTH(m) H/D(m) QUANTITY UNIT

8.59 9.51 81.69 sqm

12 1.5 1.3 1.8 42.12 cum

37.88 cum

10.88 cum

12 1.5 1.5 0.1 27.00


12 1.5 1.5 1.8
12 1.3 1.3 0.25
12 1.3 1.3 0.2
12 1.05 1.05 0.5

0.3 0.45
0.3 0.3
8.59 7.97 0.15 9.20 cum

12 1.5 1.5 1.8 129.60 sqm


12 1.3 1.3 0.45 28.08 sqm
7.9 7.3 144.04 sqm 45.84 X 3 + 6.52(STAIRCASE R
0.45 0.3 0.335 131.91 sqm 43.97X3
12 2.55 0.3 110.16 sqm 36.72X3
2 1.27 0.115 13.33 sqm .29 + (6.52 X 2)

9.76 2.55 0.23 3.27 cum


8 2.55 0.23 4.14 cum
8 2.55 0.23 4.14 cum

40.6 2.55 98.16 sqm


48.44 2.55 111.13 sqm
48.44 2.55 111.13 sqm

8.5 9.5 9 281.00 sqm


21.2 0.9 0.415 21.59 sqm

7.9 7.3 157.08 SQM


27.4(VERTICA 36.6(HORI .335(INT
L BEAM 21.44 SQM
BEAM LEN) BEAM HT)
LENGTH) 64X.335
117.68 SQM
G.F. INT PLASTER
185.50 SQM 1ST FLR INT
185.50 SQM
488.68 SQM A
157.08 SQM B
645.76 SQM

8.5 9.5 9 302.59 sqm


645.76 sqm

157.08 sqm

5.58 sqm
6.35 sqm
6.35 sqm
175.36 sqm

2 0.82 2.05 3.36 sqm


1 0.66 2.05 1.35 sqm
2 0.82 2.05 3.36 sqm
3 0.66 2.05 4.06 sqm
1 1.12 2.05 2.30 sqm
2 0.82 2.05 3.36 sqm
3 0.66 2.05 4.06 sqm
1 1.12 2.05 2.30 sqm
49.00 sqm

7.9 7.3 157.08 sqm

4.7 2 9.40 sqm

1 1.45 1.5 3.88 sqm


1 8.35 8.35 58.76 sqm

4 0.89 3.48 12.38 sqm

75.02 sqm

2 0.92 2.1 0.63 2.43 cum


1 0.76 2.1 0.63 1.01 cum
2 0.92 2.1 0.63 2.43 cum
3 0.76 2.1 0.63 3.02 cum
1 1.22 2.1 0.63 1.61 cum
2 0.92 2.1 0.63 2.43 cum
3 0.76 2.1 0.63 3.02 cum
1 1.22 2.1 0.63 1.61 cum
17.57 cum

2 0.82 2.05 3.36 sqm


1 0.66 2.05 1.35 sqm
2 0.82 2.05 3.36 sqm
3 0.66 2.05 4.06 sqm
1 1.12 2.05 2.30 sqm
2 0.82 2.05 3.36 sqm
3 0.66 2.05 4.06 sqm
1 1.12 2.05 2.30 sqm
15 24.15 sqm
.84 X 3 + 6.52(STAIRCASE ROOF) LAST ROOF

9 + (6.52 X 2)
F. INT PLASTER
S.NO. DESCRIPTION OF ITEM QTY.
1.00 EARTHWORK

Earth work in surface excavation not exceeding 30 cm in depth


but exceeding 1.5 m in width as well as 10 sqm on plan including
1.10 81.69
disposal of excavated earth up to 50 m and lift up to 1.5 m,
disposed soil to be levelled and neatly dressed All kinds of soil

Earth work in excavation by mechanical means (Hydraulic


excavator) / manual means in foundation trenches or drains (not
exceeding 1.5 m in width or 10 sqm on plan), including dressing
1.20 48.6
of sides and ramming of bottoms, lift up to 1.5 m, including
getting out the excavated soil and disposal of surplus excavated
soil as directed, within a lead of 50 m. All kinds of soil

Filling available excavated earth (excluding rock) in trenches,


plinth,sides of foundations etc. in layers not exceeding 20cm in
1.30 37.88
depth,consolidating each deposited layer by ramming and
watering, leadup to 50 m and lift upto 1.5 m.

Supplying and filling in plinth with Jamuna sand under floors,


1.40 including watering, ramming, consolidating and dressing 10.88
complete.
2.00 CONCRETE

1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40


mm nominal size) Providing and laying in position cement
2.10 concrete of specified grade excluding
the cost of centering and shuttering - All work up to plinth level
Providing and laying in position machine batched and machine
mixed design
mix M-25 grade cement concrete for reinforced cement
concrete work,
using cement content as per approved design mix, including
pumping of
concrete to site of laying but excluding the cost of centering,
2.20 shuttering,
finishing and reinforcement, including admixtures in
recommended
proportions as per IS: 9103 to accelerate, retard setting of
concrete, improve
workability without impairing strength and durability as per
direction of
Engineer-in-charge.

Upto Plinth Level


FOOTINGS
CUBOID
TRAPEZOIDAL
PART COLUMN
Above Plinth Level
BEAM
COLUMN
SLAB
UNIT RATE AMOUNT REF.

cum 5044.15 412056.61 2.1.1

cum 157.5 7654.50 2.8.1

cum 112.4 2.25

cum 910.25 9903.52 2.27

cum 4301.15 4.1.8


172.2

5.33.1

5.33.2
1.00 EARTHWORK
1.10 LEVELING
1.20 EXCAVATION
1.30 REFILING
1.40 SUPPLY AND FILLING
2.00 CONCRETE
2.10 P.C.C
2.20 R.C.C
2.30 CENTERING AND SHUTTERING
2.40 REINFORCEMENT
3.00 BRICKWORK
3.10 0.115 4.5INCH WALL
3.20 0.2 9INCH WALL
4.00 FINISHING
4.10 PLASTERING
4.20 WALL FINISHES
4.30 PAINT
4.40 FlOORING
4.50 POLISHING
4.60 FALSE CEILING
4.70 DADOING
4.80 WATERPROOFING
5.00 WOODWORK
5.10 FRAMES
5.20 SHUTTERS
5.30 HARDWARE
SNO DESCRIPTION
1.00 EARTHWORK
Earth work in surface excavation not exceeding 30 cm in depth but exceeding
1.5 m in width as well as 10 sqm on plan including disposal of excavated earth
up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed
All kinds of soil
1.10

Earth work in excavation by mechanical means (Hydraulic excavator) / manual


means in foundation trenches or drains (not exceeding 1.5 m in width or 10
sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5
m, including getting out the excavated soil and disposal of surplus excavated
soil as directed, within a lead of 50 m. All kinds of soil
1.20

Filling available excavated earth (excluding rock) in trenches, plinth,sides of


foundations etc. in layers not exceeding 20cm in depth,consolidating each
deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m.
1.30
Supplying and filling in plinth with Jamuna sand under floors, including
1.40 watering, ramming, consolidating and dressing complete.
2.00 CONCRETE
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40
mm nominal size) Providing and laying in position cement concrete of specified
grade excluding
the cost of centering and shuttering - All work up to plinth level
2.10
2.20

Providing and laying in position machine batched and machine mixed design
mix M-25 grade cement concrete for reinforced cement concrete work,
using cement content as per approved design mix, including pumping of
concrete to site of laying but excluding the cost of centering, shuttering,
finishing and reinforcement, including admixtures in recommended
proportions as per IS: 9103 to accelerate, retard setting of concrete, improve
workability without impairing strength and durability as per direction of
Engineer-in-charge.

Upto plinth level


Over plinth level
Centering and shuttering including strutting, propping etc. and removal of form
2.30 for
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Steel reinforcement for R.C.C. work including straightening, cutting,
2.40 bending, placing in position and binding all complete upto plinth level.
Hot rolled deformed bars
3.00 BRICKWORK

Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level.
3.10
Cement mortar 1:3 (1 cement :3 coarse sand)

Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level
3.20
Cement mortar 1:4 (1 cement : 4 coarse sand)
4.00 FINISHING
4.10 12 mm cement plaster finished with a floating coat of neat cement of mix
1:3 (1 cement: 3 fine sand)
Interior Finishing
4.20 White washing with lime to give an even shade
New work (three or more coats)
Exterior Finishing
4.21 Finishing walls with water proofing cement paint of required shade
New work (Two or more coats applied @ 3.84 kg/10 sqm)
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre, of approved brand
andmanufacture, including applying additional coats wherever required, to
achieve even shade and colour.
4.30
One coat

Crazy marble stone flooring, including filling the gaps with light shade pigment
with white cement marble powder mixture (3 parts of white cement: 1 part of
marble powder) by weight in proportion of 4:7 (4 cement marble powder mix :
7 white, black or white and black marble chips of sizes from 1 mm to 4 mm
nominal size by volume), with under layer 25 mm thick cement concrete 1:2:4
(1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size),
including rubbing, polishing and cement slurry etc. complete
4.40
18 mm thick crazy marble stone white, black or as specified
Chequered terrazo tiles 22 mm thick with graded marble chips of size upto 6
mm in floors, jointed with neat cement slurry mixed with pigment to match the
shade of the tiles, including rubbing and polishing complete, on 20 mm thick
bed of cement mortar 1:4 (1 cement :4 coarse sand)
4.41
Light shade pigment using white cement
Marble stone flooring with 18 mm thick marble stone, as per sample of marble
approved by Engineer-in-charge, over 20 mm (average) thick base of cement
mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry,
including rubbing and polishing complete with
4.42
Udaipur green marble
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed
with grey cement slurry mixed with pigment to match the shade of the slab,
including rubbing and polishing complete with base of cement mortar 1 : 4 (1
4.43 cement : 4 coarse sand)
25 mm thick
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of
4.44 cement mortar 1:5 ( 1cement : 5 coarse sand) with joints finished flush
White sand stone
4.50 Melamine polishing on wood work (one or more coat).
Varnishing with flatting varnish of approved brand and mamufacture one or
more coats on old work.

Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or
with design ceiling tiles of BWP type phenol formaldehyde synthetic resin
bonded pressed particle board conforming to IS:3087, finished with a coat of
aluminium primer on both sides & edges, including two coats of
synthetic enamel paint of approved quality on exposed face, fixed to a grid
made out of anodised aluminium (with 15 micron anodic coating) Tsections 35
x15x1.5 mm size main runners, cross runners 23.5x19x1.5 mm fixed to main
runners placed 600 mm centre to centre both ways so as to form a grid of 600
mm square. The frame work shall be suspended
from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab
by means of ceiling cleats and dash fastener. The suspenders shall be placed
600 x 1200 mm centre to centre including fixing to the frame with C.P brass
screws and applying a priming coat of zinc chromate yellow primer (aluminium
frame work shall be paid separately).
4.60
Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm
thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with
grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed
4.70 with pigment of matching shade complete.
Marble tiles (polished) Raj Nagar
Providing and laying integral cement based water proofing treatment including
preparation of surface as required for treatment of roofs, balconies, terraces
etc consisting of following operations: a) Applying a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with water proofing compound
conforming to IS. 2645 and approved by
Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm
height including cleaning the surface before treatment. b) Laying brick bats
with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of
cement mortar 1:5 (1 cement : 5 coarse sand) admixed with
water proofing compound conforming to IS : 2645 and approved by Engineer-
in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5
coarse sand ) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge to required slope and treating similarly
the adjoining walls upto 300 mm height
including rounding of junctions of walls and slabs c) After two days ofproper
curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement
admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse
sand) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge including laying glass fibre cloth of approved
quality in top layer of plaster and finally finishing the surface with trowel with
neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e)
The whole terrace so finished shall be flooded with water for a minimum
period of two weeks for curing and for final test. All above operations to be
4.80 done in order and as directed and specified by the Engineerin- Charge
With average thickness of 120 mm and minimum thickness at
khurra as 65 mm.
5.00 WOODWORK
Providing wood work in frames of doors, windows, clerestory windows and
other frames, wrought framed and fixed in position with hold fast lugs or with
dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be
5.10 paid for separately).
Sal wood
Providing and fixing panelled or panelled and glazed shutters for doors,
windows and clerestory windows, including ISI marked M.S. pressed butt
hinges bright finished of required size with necessary screws, excluding
panelling which will be paid for separately, all complete as per direction of
Engineer-in-charge.
5.20
Second class teak wood
Providing and Fixing factory made uPVC white colour casement/sliding window
/ door, made of extruded profiles. Profiles of frames and sash will be mitered
cut and fusion welded at all corners, including drilling of holes for fixing
hardware and drainage of water etc., making arrangement for
fixing of hardware, EPDM gasket, 1.2 0.2 mm thick galvanised steel profile to
be inserted in required profile, frame will be fixed to the wall with 8 mm x 100
mm long fasteners, all complete as per direction of Engineerin-
charge. (Glazing, hardware hinges and fitting etc. to be paid separately.)

5.30
Casement Window (Outward/Inward opening) with hinge System
Casement Frame (67 mm x 62 mm)
Sliding Window (Two Track, 2/4 Shutters)
Sliding Door (Two Track, 2/4 Shutters)
Reference No Cost Unit

2.1.1 5,044.15 cum

2.8.1 157.5 cum

2.25 112.4 cum

2.27 910.25 cum

4.1.8 4301.15 cum

172.2 cum

5.33.1 6296.15 cum


5.33.2 7014.55 cum

5.9.1 196.45 sqm


5.9.3 401.65 sqm
5.9.5 332.15 sqm
5.9.6 453.35 sqm
5.9.7 395.65 sqm

5.22.4 kg

6.13.1 5667.55

6.4.1 692.8

13.7
13.7.1
13.37
13.37.1
13.44
13.44.1

13.82

13.82.1

11.15

11.15.1
11.19

11.19.1

11.23

11.23.5

11.26

11.26.1
11.28
11.28.2
14.70

14.71

12.29

11.22

11.22.1
22.7

22.7.1

9.1

9.1.2

9.5

9.5.1
9.147

9.147.1
9.147.2.1
9.147.3
9.147.4

You might also like