PNMTj for PASOLINK NEO

Issue-2 (2WAY XC added)

Provided for Training / Jan 2008

TOPC-E4015E-02-07416
PASOLINK NETWORK MANAGEMENT TERMINAL java

PASOLINK NETWORK MANAGEMENT TERMINAL java (PNMTj) IS A MOBILE TERMINAL CONSISTING


OF A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK
MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC SDH/PDH RADIO
TRANSMISSION NETWORKS.

PNMTj IS DESIGNED AS AN ONSITE MAINTENANCE


TOOL TO BE USED BY THE FIELD ENGINEERS AND
TECHNICIANS. IT CONNECTS DIRECTLY TO THE
RADIO EQUIPMENT. PNMTj CAN BE USED TO
MONITOR LOCAL / REMOTE EQUIPMENT STATUS
AND PROVIDES CONTROL CAPABILITIES SIMILAR
TO THOSE AVAILABLE IN PNMS.

PNMTj IS ALSO USED TO DOWNLOAD THE SYSTEM


CONFIGURATION FILES CREATED BY THE
NETCONFIG TOOL, TO THE EQUIPMENT AND ALSO
UPGRADE THE SOFTWARE

WHEN CONNECTED TO A RADIO, PNMTj CAN


MONITOR NOT ONLY THE LOCAL EQUIPMENT BUT
ANY REMOTE NETWORK ELEMENT UNDER THE
CONTROL OF THE ROOT NETWORK ELEMENT.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 1


FUNCTIONS

MICROSOFT WINDOWS VISTA / XP WORKSTATION GRAPHICAL USER INTERFACE


ONE HOP LINK DISPLAY ON THE PNMTj SCREEN
COMMUNICATE WITH REMOTE CTRL MODULE ON THE SAME NETWORK
COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE CTRL MODULES
TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE CTRL MODULES
SEVERAL LEVELS OF LOGIN / LOGOUT
EVENT LOGGING WINDOW
PERFORMANCE MONITORING FUNCTION WINDOW
LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION
LOCAL/REMOTE CTRL MODULE CONFIGURATION MANAGEMENT
LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 2


PNMTj COMMUNICATION INTERFACE
COMMUNICATION BETWEEN THE PNMTj AND THE PASOLINK NEO IS VIA THE LCT PORT OF THE CTRL MODULE

THE PNMTj AND THE CTRL MODULE


MOUNTED ON THE PASOLINK NEO
MUST BE CONNECTED USING A USB
A-B TYPE CABLE. TYPE-B
CONNECTS TO THE LCT PORT.

LCT PORT SPECIFICATION

CONNECTOR TYPE USB Type B (Female)

BITS PER SECOND RATE 1200/2400/4800/9600/19200

STOP BITS 1

DATA LENGTH 8

PARITY No Parity

PNMT PC SPECIFICATION SOFTWARE REQUIREMENT

CPU Pentium-M 1.6GHz or better OS WINDOWS XP PROFESSIONAL (ENGLISH) SP2


WINDOWS VISTA Business Edition (English Version) SP! Or higher
RAM 512 MB or more
IE 6 WITH SP2 PR HIGHER
HDD 40 GB or more
PNMT APPLICATION SOFTWARE (NEC)
DISPLAY Color LCD (1024x768)
ADOBE READER
FD DRIVE/CD ROM DRIVE/USB-PORT/SERIAL PORT
10/100BASE-T(X) LAN/

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 3


PASOLINK MANAGEMENT
CTRL are located at each site (IDU) in the monitored network to collect alarm/status information from the
equipment. CTRL is also used to control the PASOLINK equipment in response to commands from
PNMSj/PNMTj.
Primary task of the CTRL is to control and acquire data from PASOLINKS at remote location and transfer
this data back to PNMSj/PNMTj.
In each Network, one CTRL module is configured as the Root NE and the others as Branch NE or
Normal NE, depending on the role it plays in the Network Management System.

COLLECTING PERFORMANCE MONITOR DATA


CTRL module function as a SNMP Agent, which detects alarm and status changes in the monitored
equipment, and sends the change notification to PNMSj via the Root NE.
CTRL module also retains the MIB data and transmit a response to SNMP GET command from
PNMTj/PNMSj..

COLLECTING PERFORMANCE MONITOR DATA


Performance measurement equivalent to ITU-T G.826/ G.828 standard are stored in the CTRL module.
Per 15 Minutes data for 7 days - Errored Second Ratio (ESR)
- Severely Erred Second Ratio (SESR)
Per Day data for 7 days
- Unavailable Second Ratio (UASR)
- Background Block Error Ratio (BBER)
COLLECTING EVENT LOG DATA - Severely Errored Period (SEP)
Keep event log of changed MIB data. Up to 1000 - Status Change
events are stored in the IDU in ASCII format - Alarm Occurrence
- Alarm Recovery
- Control Initiation
- Parameter Change

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 4


START UP
CONNECT THE PNMTj PC USB PORT AND THE PASOLINK IDU LCT PORT USING AN USB CABLE PREPARATION
Connect the USB cable to the PNMTj PC
DOUBLE CLICK ON THE PNMT and the IDU LCT port. From the add new
SHORTCUT ICON ON THE DESKTOP device wizard install the USB MODEM
OR CLICK ON START>>ALL driver and assign it to the COM1 port ( or
PROGRAMS >>PNMTj>>PNMT
the COM port to be used)
Create a Dial-up connection using the
above USB modem and name it as
PNMT(USB)

Install the NEC PNMTj software

See PNMTj Install Manual for details

ENTER THE USER NAME


ACCORDING TO THE PRIVILEGES
AND THE PASSWORD.
SELECT THE CONNECTION TYPE
RADIO BUTTON DIAL UP
SELECT THE DIAL UP ENTRY
PNMT(USB)
CLICK LOGIN

TO PROTECT THE NETWORK AND


NETWORK MANAGEMENT
SYSTEM FROM UNAUTHORIZED
ACCESS OR MODIFICATIONS,
FIVE LEVELS OF USERS ARE
DEFINED WITH DIFFERENT PNMT PROGRAM CONNECT TO THE IDU
PRIVILEGES. THE FUNCTIONS USING THE DIALUP CONNECTION
AVAILABLE DEPENDS ON THE PNMT(USB) AND OPEN THE PNMT
USER ACCESS LEVEL. WINDOW

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 5


PNMT MAIN SCREEN
PNMTj MAIN SCREEN IS SPLIT TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.

PNMTj WINDOW
MENU BAR
COMMON TOOL BAR
LINK SUMMARY WINDOW

NE-SPECIFIC MENU ITEMS


STATION NAME

BLOCK DIAGRAM

Click on the equipment


172.018.000.005
symbols or the four buttons
to open detail windows

NE-SPECIFIC DATA

Login user

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 6


NE BLOCK DIAGRAM
PASOLINK NEO PDH CONFIGURATION (1+0) AND (1+1)

NE BLOCK DIAGRAM FOR (1+0) NE BLOCK DIAGRAM FOR (1+1)


CONFIGURATION CONFIGURATION

PASOLINK NEO SDH CONFIGURATION (1+1) AND (APS)

NE BLOCK DIAGRAM FOR (1+1) STM-1 NE BLOCK DIAGRAM FOR (1+1) STM-1
SDH CONFIGURATION APS CONFIGURATION

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 7


BLOCK DIAGRAM
PASOLINK NEO PDH REPEATER CONFIGURATION

BLOCK DIAGRAM ON THE PNMT NETWORK


ELEMENT WINDOW MIMIC THE NEO
EQUIPMENT CONFIGURATION

CLICKING ON THE MODULE SYMBOL OR THE


BUTTONS BELOW, OPEN THE DETAIL WINDOW
OF THE SELECTED MODULE OR ITEM
172 .018. 000. 005

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 8


NEO/c BLOCK DIAGRAM
PASOLINK NEO/c CONFIGURATION (1+0) AND (1+1)
NE BLOCK DIAGRAM FOR (1+0 FIX)
CONFIGURATION BLOCK DIAGRAM ON THE PNMT NETWORK ELEMENT
WINDOW MIMIC THE NEO/c EQUIPMENT CONFIGURATION

RED - MAJOR

GREEN - NORMAL

PINK - MINOR

WHITE - STATUS

YELLOW - MAINTENANCE

BLACK NOT CONFIGURED MODULE


GRAY PS ALARM

NE BLOCK DIAGRAM FOR (1+0 EXPANDABLE) NE BLOCK DIAGRAM FOR (1+1)


CONFIGURATION CONFIGURATION

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO/c 9


PNMT MAIN SCREEN - REPEATER
TERMINAL A REPEATER TERMINAL B

ATT
ATT

(1+0) Configuration
(1+0) Configuration

172.018.000.003
172.018.000.004 172.018.000.005

Click here to display the opposite


NE in DIR-A

Click here to display the opposite 172.018.000.005


NE in DIR-B

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 10


SYSTEM MENU CHANGE PASSWORD / EXIT
CHANGEPASSWORD
CHANGE PASSWORD
CLICK THE SYSTEM MENU AND FROM THE DROPDOWN MENU
SELECT CHANGE PASSWORD

ENTER THE OLD PASSWORD

ENTER THE NEW PASSWORD

ENTER THE NEW PASSWORD


AGAIN TO CONFORM

CLICK OK TO CHANGE PASSWORD

CLICK CANCEL TO EXIT WITHOUT CHANGING THE PASSWORD

EXIT

TO EXIT THE PNMT PROGRAM CLICK ON


EXIT, IN THE SYSTEM DROPDOWN MENU
AND CLICK OK.

CLICK CANCEL TO CLOSE THE DIALOG THE SCREEN INDICATES PLEASE WAIT. IT WILL TAKE FEW MINUTES
WINDOW TO SHUTDOWN

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 11


SYSTEM MENU ALARM BUZZER
ALM

buzzz

WHEN THE BUZZER IS ENABLED AND AN ALARM OCCUR PNMT PC


THE BUZZER ICON ON THE TOOL BAR IS ACTIVE AND
THE BUZZER SOUNDS. CLICK ON THE BUZZER ICON TO
ACKNOWLEDGE THE ALARM AND STOP THE BUZZER

CLICK ON THE SYSTEM MENU AND SELECT ALARM


BUZZER FORM THE DROP DOWN MENU

SELECT THE RADIO BUTTON FOR THE ALARM BUZZER


SETTING

SELECT NO SOUND RADIO BUTTON TO DISABLE


THE BUZZER SOUND. (DEFAULT SETTING) Test Button
SELECT WAVE FILE RADIO BUTTON TO ENABLE
THE BUZZER SOUND.

IF WAVE FILE RADIO BUTTON IS SELECTED, ENTER THE


PATH AND THE WAVE FILE NAME OR CLICK ON THE
BROWSE BUTTON AND SELECT THE WAVE FILE Browse Button

CLICK THE APPLY BUTTON

CLICK THE TEST BUTTON TO CHECK THE ALARM


SOUND OF THE SELECTED WAVE FILE

CLICK THE OK BUTTON TO CLOSE THE ALARM BUZZER


SETTING WINDOW

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 12


SEARCH / CONNECT TO REMOTE NETWORK ELEMENT
CLICK CONNECT ON THE SYSTEM DROP DOWN MENU OR
1 CONNECT ICON ON THE TOOL BAR TO LIST THE LOCAL NEs
THE PNMTj IS CONNECTED TO.

CONNECT ICON

2 CLICK THE LIST MENU AND SEARCH


FOR NETWORK ELEMENT OR SEARCH
FOR NETWORK ELEMENT ICON IN THE
TOOL BAR TO SEARCH AND LIST THE
OTHER NEs IN THE NETWORK

CONNECT TO NETWORK ELEMENT

SEARCH FOR NETWORK ELEMENT

3 TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT


LIST, SELECT AND HIGHLIGHT THE NE IN THE LIST.
THEN CLICK THE CONNECT TO NETWORK ELEMENT
FROM THE LIST DROP DOWN MENU. SELECT YES FROM
THE DIALOG BOX. THE SELECTED NE AND ITS
OPPOSITE NE WILL BE DISPLAYED IN THE LINK
SUMMARY WINDOW. ITD 003

Simultaneous connection from multiple PNMT to the same NE is


possible.
1.Local Connection PNMT directly connected to the NE . .. ...
2. Opposite Connection- PNMT is connected to the opposite NE....
3. Remote Connection PNMT is connected to the NE via remote NE

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 13


USER NAMES & PRIVILEGES
Category Item Monitor (0) User (1) Local (2) Remote (3) Admin (4)
ALARM BUZZER
System
CONNECT (REMOTE LOGIN)
Wizard setting
Equipment Setup NE Name
Note
CH USAGE
CH USAGE ERROR REPORT
Admin - enable access to all
AIS ACTIVATION CONDITION
network elements
Channel Setting AIS GENERATED REPORT
Remote - enable access to AIS RECEIVED REPORT
all network elements (disable AIS RECEIVED CONDITION
network configuration
E1 PORT IMPEDANCE
changes/downloads and
DXC CH Setting DXC Function
program downloads)
HIGH BER THRESHOLD
Local enable access to
LOW BER THRESHOLD
local NE and opposite NE
E-BER (DMR)
(disable network BER Threshold
configuration changes / SD (DMR)
downloads and program E-BER (MUX)
downloads SD (MUX)
User enable access to RS-232C 1 & 2
local NE but allows items
V.11 1 & 2
which dose not affect the SC Assignment
V.11 DIRECTION
equipment
SC LAN
Monitor enable monitor Provisioning
PORT # USAGE
only and disable controls
SWITCHING FUNCTION
SPEED & DUPLEX PORT # / (GbE)
FLOW CONTROL PORT # / (GbE)
LAN Port Setting COLLISION REPORT PORT #
LINK LOSS FORWARDING PORT # / (GbE)
CLOCK SOURCE SETTING
2M FRAMING
MEDIA TYPE

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 14


USER NAMES & PRIVILEGES
Category Item Monitor (0) User (1) Local (2) Remote (3) Admin (4)
Provisioning TX Power Control MTPC TX POWER
ATPC RX THRESHOLD LEVEL
ADDITIONAL ATT
ATPC RANGE (MAX)
ATPC RANGE (MIN)
ATPC POWER MODE
Condition for TX SW PRIORITY
Admin - enable access to all TX/TX SW RX SW PRIORITY
network elements RX SW MANUAL MODE
RX SW CONDITION EARLY WARNING
Remote - enable access to
all network elements (disable RX SW CONDITION XPIC RESET
network configuration Conditions for APS APS MANUAL MODE
changes/downloads and APS CONDITION - SF
program downloads)
APS CONDITION SIGNAL DEGRADE
Local enable access to LOCK IN USAGE
local NE and opposite NE LOCK IN COUNT
(disable network
LOCK IN DETECT TIME
configuration changes /
LOCK IN HOLD TIME
downloads and program
downloads RELAY RELAY CONFIGURATION CHANGED
User enable access to TCN THRESHOLD TCN THRESHOLD
local NE but allows items XPIC CONDITION XPIC CONDITION LOCAL FAIL
which dose not affect the EOW IF TYPE EOW2 EXTERNAL SETTING
equipment
PMON SELECT RX LEV TCN THRESHOLD
Monitor enable monitor SES ACTIVATION CONDITION
only and disable controls
ALS ALS FUNCTION
ALS INTERVAL
ALARM ALARM CORRELATION CAPABILITY
CORRELATION
AUX I/O INPUT
OUTPUT
CLUSTER ALARM 1 ~ 4
PMON PMON PMON THRESHOLD
SAVE TO SIDK
EVENT LOG SAVE TO DISK

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 15


USER NAMES & PRIVILEGES
Category Item Monitor (0) User (1) Local (2) Remote (3) Admin (4)
MAINTENANCE MODE
TX SW MANUAL CONTROL
RX SW MANUAL CONTROL
ATPC MANUAL CONTROL
TX MUTE CONTROL TX MUTE OFF CONTROL TIME
CW CONTROL
APS MANUAL CONTROL
Admin - enable access to all
IF LOOP BACK
network elements
MAIN CH LOOPBACK-1
Remote - enable access to MAINTENANCE
MAIN CH LOOPBACK-2
all network elements (disable MAIN LOOPBACK -1
network configuration
MAIN LOOPBACK-2
changes/downloads and
DADE ADJUST
program downloads)
LAN DEVICE RESET
Local enable access to
ALS RESTART
local NE and opposite NE
XPIC CONTROL
(disable network
configuration changes / RF SUB BAND SELECT
downloads and program ANTENNA ALIGNMENT MODE
downloads DATE / TIME SETTING
User enable access to CPU RESET
local NE but allows items
CONFIGURATION FILES
which dose not affect the
PROGRAM FILES
equipment
DOWNLOAD
EQUIPMENT CONFIG FILES
Monitor enable monitor CTRL
only and disable controls SOFTWARE KEY FILE
CONFIGURATION FILES

UPLOAD EQUIPMENT FILES


SOFTWARE KEY FILE
EQUIPMENT NETWORK SETTING

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 16


DETAIL WINDOW

ITEM COLUMN INDICATE


CLICK ON THIS ICON TO
THE ALARM AND
OPEN THE ACTIVE
STATUS ITEMS FOR THE
ALARM LIST
SELECTED MODULE
CLICK ANY OF THE ICONS
IN THE BLOCK DIAGRAM
WINDOW TO OPEN THE
CORRESPONDING DETAIL
WINDOW

CATEGORY COLUMN
STATUS COLUMN
INDICATE THE CH # IN
INDICATE THE
(1+1) CONFIGURATION
STATUS OF EACH
AND COMMON ITEMS
ITEM

CLICK ON THE TABS TO SEE DETAIL ALARM/STATUS OF


ODU, MODEM, MAIN INTFC, AUX I/O ETC

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 17


PNMT DETAIL WINDOWS
TX/ RX RF FREQUENCY CURRENTLY USED TX AND RX FREQUENCIES

TX POWER CONTROL TX POWER CONTROL MODE USED MTPC OR ATPC

MTPC TX POWER MTPC TX POWER LEVEL IN DB (ATTENUATION FORM NOMINAL LEVEL ) (MTPC MODE
ONLY)
FRAME ID ASSIGNED RADIO FRAME ID

MAIN (WORK) INTFC (1) TYPE OF INTERFACE USED IN MAIN INTFC SLOT (PDH / SDH CONFIGURATION)

SUB (PROT) INTFC (2) TYPE OF INTERFACE USED IN SUB INTFC SLOT (SDH CONFIGURATION)

TRANSMISSION CAPACITY THE TRANSMISSION CAPACITY USED FOR PDH OR (PDH + LAN ) OR SDH OR LAN

MODULATION SCHEME MODULATION SCHEME USED

TX SW STATUS ONLINE MODEM AND ODU USED IN TX DIRECTION (FOR 1+ 1 HOT STANDBY
CONFIGURATION)

RX SW STATUS ONLINE MODEM AND ODU USED IN RX DIRECTION ( 1+1 SYSTEM ONLY)
XPIC USAGE IN SDH CONFIGURATION XPIC USED OR NOT
172.018.000.005
STACK MODE STATUS OF STACK MODE WHEN USED

ALS FUNCTION AUTOMATIC LASER SHUT DOWN ENABLED OR DISABLED (OPTICAL INTERFACE ONLY)

APS ONLINE STATUS IN AUTOMATIC PROTECTION SWITCHING WHICH INTERFACE IS ONLINE WORKING OR
PROTECTION

OVERALL STATUS WINDOW (1+1) OVERALL STATUS WINDOW (1+0)

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 18


ODU DETAIL
TX ALARMS
CLICK THE ODU SYMBOL IN THE
BLOCK DIAGRAM OR THE ODU TX POWER INDICATE STATUS OF TX RF POWER. ALARM WHEN TX POWER IS 3 dB
TAB IN THE DETAIL WINDOW TO DOWN FROM THE PRESET VALUE OR ATPC MINIMUM SET VALUE
SEE THE ODU ALARM AND
TX INPUT INDICATE THE STATUS OF IF INPUT TO ODU. ALARM WHEN INPUT TX IF
STATUS DETAIL SIGNAL FROM THE IDU IS LOST
ODU LINEARIZER INDICATE THE STATUS OF THE LINEARIZER IN THE ODU. ALARM
WHEN AN ANOMALY OCCURS IN THE LINEARIZER. (NOT SHOWN IN NEOc ODU (CPV))

RX ALARMS

RX LEVEL INDICATE STATUS OF RX SIGNAL LEVEL. ALARM WHEN RX SIGNAL


DROPS BELOW THE THRESHOLD LEVEL

COMMON ALARMS

ODU TYPE MISMATCH INDICATE ALARM WHEN DIFFERENT TYPE OF ODU IS


CONNECTED TO THE IDU (Example: WHEN CPV TYPE ODU IS CONNECTED) OR THE
ODU DOES NOT SUPPORT THE IDU CONFIGURATION (256 QAM)
APC INDICATE STATUS OF SYNTHESIZER IN THE ODU. ALARM WHEN THE PHASE
LOCK LOOP IS UNLOCKED

ODU CPU / CABLE OPEN INDICATE ABNORMALITY OF THE CPU IN THE ODU OR
COMMUNICATION BETWEEN ODU AND IDU IS LOST (MAY BE DUE TO CABLE OPEN)

LO REF LOSS OF REFERENCE LOCAL OSCILLATOR FROM THE MODEM (XPIC)

STATUS

TX SW STATUS: ONLINE MODEM AND ODU USED IN TX DIRECTION (FOR 1+ 1 HOT


STANDBY CONFIGURATION)
RX SW STATUS ONLINE MODEM AND ODU USED IN RX DIRECTION (FOR 1+ 1
CONFIGURATION)
TX SW LOCK-IN STATUS INDICATES THE STATUS OF TX SW LOCK-IN STATUS
(FOR 1+ 1 CONFIGURATION)
TCN ALARMS
TX SW REVERSE REQUEST INDICATES THE STATUS OF TX SW REVERSE REQUEST
TCN-RX LEV-15 Min INDICATE WHETHER THE RX LEVEL IS BELOW THE PRESET (FOR 1+ 1 CONFIGURATION)
THRESHOLD LEVEL DURING THE 15 MIN
MUTE STATUS ODU TX RF ON / OFF STATUS IN HOT STANDBY .
TCN-RX LEV-1DAY INDICATE WHETHER THE RX LEVEL IS BELOW THE PRESET
THRESHOLD LEVEL FOR THE DAY MUTE STATUS ON ( TX RF OFF)
MUTE STATUS OFF (TX RF ON).

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 19


MODEM DETAIL (1)
CLICK THE MODEM
SYMBOL IN THE
BLOCK DIAGRAM OR
THE MODEM TAB IN
THE DETAIL WINDOW TX ALARMS
TO SEE THE MODEM
ALARM AND STATUS 172 .018. 000. 005 MOD INDICATE STATUS OF MODULATOR, ALARM IF ANY ABNORMALITY OCCURS
DETAIL
LINEARIZER INDICATE THE LINEARIZER OPERATING STATUS, WHEN THE
LINEARIZER IS NOT OPERATING PROPERLY ALARM IS ISSUED AND THEN OUTPUT
POWER IS REDUCED (NOT AVAILABLE FOR QPSK MODULATION AND WHEN
CONNECTED TO CPV ODU)

RX ALARMS

DEM: INDICATE THE OPERATING STATUS OF THE DEMODULATOR, ALARM IF ANY


ABNORMALITY OCCURS
LOF: INDICATE THE RADIO FRAME SYNCHRONIZATION STATUS. ALARM WHEN FRAME
SYNCHRONIZATION FROM DMR IS LOST
FRAME ID: INDICATES THAT FRAME ID RECEIVED AND THE NE FRAME ID IS IN
SYNCHRONIZATION OR NOT
HIGH BER: INDICATES THE QUALITY OF RECEIVE RADIO SIGNAL. ALARM WHEN THE
SIGNAL DETERIORATES BELOW THE PRESET HBER THRESHOLD LEVEL. SEND AIS
TOWARDS THE MUX DIRECTION (PRESETABLE VALUES ARE 1E-3, 1E-4 & 1E-5)
LOW BER: INDICATES THE QUALITY OF RECEIVE RADIO SIGNAL. ALARM WHEN THE
SIGNAL DETERIORATES BELOW THE PRESET LBER THRESHOLD LEVEL. INITIATE
SWO IN THE CASE OF (1+1) CONFIGURATION (PRESETABLE VALUES ARE 1E-6, 1E-7,
1E-8 & 1E-9)

EARLY WARNING: INDICATES THE QUALITY OF RECEIVE RADIO SIGNAL. ALARM


WHEN THE SIGNAL DETERIORATES BELOW 1E-9 BER THRESHOLD LEVEL. INITIATE
SWO IN THE CASE OF EARLY WARNING AS A SWO CRITERIA)

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 20


MODEM DETAIL (2)
COMMON ALARMS

MODEM MODULE: INDICATE THE TOTAL ALARM OF MODULATOR AND DEMODULATOR.


ALARM WHEN ANY ABNORMALITY DETECTED IN MODULATOR AND/OR DEMODULATOR
MODEM UNEQUIPPED: IF A MODEM CARD IS NOT MOUNTED ACCORDING TO THE
EQUIPMENT SETUP OR MODEM IS NOT PROPERLY MOUNTED

172 .018. 000. 005 IF CABLE SHORT INDICATES THE STATUS OF THE IF CABLE BETWEEN THE IDU AND
ODU. IF A SHORT CIRCUIT CONDITION OCCURS IT IS DETECTED IN THE MODEM PS
AND ALARM IS ISSUED
INPUT VOLTAGE: INDICATES WHETHER THE INPUT VOLTAGE IS WITHIN LIMITS. IF IT
EXCEED THE LIMITS, ALARM IS ISSUED
POWER SUPPLY: INDICATE THE OPERATING STATUS OF THE POWER SUPPLY, IF
THERE IS ANY ABNORMALITY IN PS, ALARM IS ISSUED
CABLE EQUALIZER: INDICATES WHETHER THE IF CABLE EQUALIZER IS
FUNCTIONING NORMALLY OR NOT
MODEM TYPE MISMATCH: INDICATES THAT CTRL F/W VER. (4.X.X) AND MODEM
PARAMETER VER. (50 OR HIGHER) ARE NOT COMPATIBLE (PDH-XPIC) OR COMPACT
MODEM MOUNTED ON NEO STD.

STATUS

ATPC POWER MODE INDICATE OPERATING STATUS OF ATPC IS ACTIVE . IF THE


ATPC CONTROL IS NOT PROPERLY FUNCTIONING, DISABLE THE ATPC CONTROL
AND MAINTAIN TX OUTPUT AT ATPC MAX, ATPC MIN OR HOLD

LINEARIZER FUNCTION : INDICATES THE STATUS OF LINEARIZER.


OPR WHEN THE LINEARIZER FUNCTION IS USED
NO OPR WHEN THE LINEARIZER FUNCTION IS NOT USED. IN THIS
CASE OUTPUT POWER DECREASE BY ABOUT 4 dB FROM NOMINAL
N/A WHEN THE ODU USED IS WITHOUT THE LINEARIZER FUNCTION
(NOT AVAILABLE FOR QPSK MODULATION OR CPV ODU CONNECTION))

XPIC

XIF INDICATE STATUS OF CROSS IF INPUT SIGNAL OF THE MAIN MASTER AND SUB
MASTER IDU. WHEN XIF INPUT SIGNAL IS LOST, ALARM IS ISSUED.
XPIC STATUS INDICATE THE STATUS OF XPIC CONFIGURATION. WHEN XPIC IS
RESET , RESET IS INDICATED AND THE RESET LED IN THE MODEM PANEL LIGHTS.
XREF INDICATE THE STATUS OF REFERENCE CLOCK SIGNAL USED IN V/H
POLARIZATION SIGNAL SYNCHRONIZATION. WHEN THE REF OSC FAILS IN THE
MODEM, ALARM IS ISSUED.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 21


MAIN INTFC DETAIL (PDH E1))
CLICK THE INTFC SYMBOL IN THE TX ALARMS
BLOCK DIAGRAM OR THE INTFC
INPUT LOS CH xx INDICATE THE STATUS OF E1 SIGNAL INPUT FROM MUX. WHEN
TAB IN THE DETAIL WINDOW TO
LOSS OF INPUT SIGNAL IS DETECTED, ALARM IS ISSUED (CH USAGE IS SET AS USED)
SEE THE INTFC ALARM AND
STATUS DETAIL USAGE ERROR CH xx INDICATE THE STATUS OF E1 SIGNAL INPUT IN CHANNELS
SELECTED AS NOT USED. WHEN AN E1 SIGNAL IS DETECTED AT THE INPUT OF A
CHANNEL SET AS NOT USED, ALARM IS ISSUED. THIS ALARM ITEM IS AVAILABLE
WHEN CH USAGE ERROR IS SET TO REPORT IN PROVISIONING
AIS RECEIVED CH xx INDICATE THE STATUS OF E1 SIGNAL FROM THE MUX. WHEN
AIS IS RECEIVED FROM MUX THIS ALARM IS ISSUED. THIS ALARM ITEM IS SHOWN
WHEN AIS RECEIVED IS SET TO REPORT IN PROVISIONING. (SEE STATUS)

RX ALARMS

UAE (TOTAL): IF THE RECEIVE TRAFFIC GOES TO UNAVAILABLE SECONDS IN


PERFORMANCE MONITOR, THIS ALARM IS ISSUED TO INDICATE THAT AN UN
AVAILABLE EVENT (UAE) IS OCCURRING IN THE NE.

COMMON ALARMS

INTFC (X) MODULE: INDICATE THE OPERATING STATUS OF THE INTFC (x) CARD.
WHEN ANY FAILURE OCCURS IN THE INTFC CARD THIS ALARM IS ISSUED
INTFC (x) UNEQUIPPED: IF THE INTFC (x) CARD IS NOT MOUNTED ACCORDING TO
THE EQUIPMENT SETUP OR INTFC(x) IS NOT PROPERLY MOUNTED THIS ALARM IS
ISSUED
INTFC (x) TYPE MISMATCH: IF THE INTFC (x) CARD MOUNTED IS DIFFERENT FORM
THE INTFC CARD CONFIGURED IN SETUP, THIS ALARM IS ISSUED.

STATUS

INTFC (x) INPHASE: INDICATE THE STATUS OF THE RECEIVE SIGNAL FROM RADIO
CH1 AND RADIO CH2 IN (1+1) CONFIGURATION. IF THE DELAY BETWEEN THE TWO
SIGNALS ARE NOT IN PHASE AT THE INPUT OF THE HITLESS SWITCH OUT PHASE IS
INDICATED.
AIS GENERATED CHxx: INDICATE THE STATUS OF THE OUTPUT E1 SIGNAL TO THE
MUX. WHEN AIS GENERATED IN THE INTFC CARD IS SENT TO THE MUX EQUIPMENT
THIS ALARM IS ISSUED. THIS ALARM ITEM IS SHOWN WHEN THE AIS GENERATED IS
SET TO REPORT IN PROVISIONING. ( OCCUR WHEN LOS AT THE OPPOSITE STATION
OR DUE TO HBER, LOF IN LOCAL STATION)
AIS RECEIVED CH xx THIS EVENT CAN BE CONSIDERED AS A STATUS EVENT
WHEN AIS RECEIVED CONDITION IS SET TO STATUS IN THE PROVISIONING

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 22


MAIN INTFC DETAIL (STM-1)
TX ALARMS
CLICK THE INTFC SYMBOL IN THE
BLOCK DIAGRAM OR THE INTFC STM-1 LOS (MUX) INDICATE THE STATUS OF STM-1 INPUT SIGNAL FROM MUX.
TAB IN THE DETAIL WINDOW TO WHEN LOSS OF INPUT SIGNAL IS DETECTED, ALARM IS ISSUED
SEE THE INTFC ALARM AND STM-1 LOF (MUX) INDICATE THE STATUS OF STM-1 INPUT SIGNAL FROM MUX.
STATUS DETAIL WHEN LOSS FRAME SYNCHRONIZATION IS DETECTED, ALARM IS ISSUED
STM-1 E-BER (MUX) INDICATE THE EXCESSIVE BER STATUS OF STM-1 INPUT
SIGNAL FROM MUX. WHEN E-BER IS DETECTED, ALARM IS ISSUED
STM-1SD (MUX) INDICATE THE SIGNAL DEGRADE STATUS OF STM-1 INPUT SIGNAL
FROM MUX. WHEN SD IS DETECTED, ALARM IS ISSUED

RX ALARMS

UAE (DMR/MUX): IF THE RECEIVE TRAFFIC GOES TO UNAVAILABLE SECONDS IN


PERFORMANCE MONITOR, THIS ALARM IS ISSUED TO INDICATE THAT AN UN
AVAILABLE EVENT (UAE) IS OCCURRING IN THE NE.
STM-1 LOS (DMR) INDICATE THE STATUS OF STM-1 INPUT SIGNAL FROM DMR.
WHEN LOSS OF INPUT SIGNAL IS DETECTED, ALARM IS ISSUED
STM-1 LOF (DMR) INDICATE THE STATUS OF STM-1 INPUT SIGNAL FROM DMR.
WHEN LOSS FRAME SYNCHRONIZATION IS DETECTED, ALARM IS ISSUED
STM-1 E-BER (DMR) INDICATE THE EXCESSIVE BER STATUS OF STM-1 INPUT
SIGNAL FROM DMR. WHEN E-BER IS DETECTED, ALARM IS ISSUED
STM-1 SD (DMR) INDICATE THE SIGNAL DEGRADE STATUS OF STM-1 INPUT SIGNAL
FROM DMR. WHEN SD IS DETECTED, ALARM IS ISSUED
STM-1 TF INDICATE THE STATUS OF STM-1 OUTPUT SIGNAL FROM INTFC. WHEN
THERE IS NO OUTPUT PULSE STREAM FROM THE INTFC, ALARM IS USED
STM-1 OUTPUT CONTROL SHOWS THE STM-1 OUTPUT CONDITION UNDER MS-AIS
GENERATION DISABLED. WHEN UNFRAMED AIS IS SENT INDICATE UNDER EXECUTION

COMMON ALARMS

INTFC (X) MODULE: INDICATE THE OPERATING STATUS OF THE INTFC (x) CARD.
WHEN ANY FAILURE OCCURS IN THE INTFC CARD, THIS ALARM IS ISSUED
STATUS INTFC (x) UNEQUIPPED: IF THE INTFC (x) CARD IS NOT MOUNTED ACCORDING TO
THE EQUIPMENT SETUP OR INTFC(x) IS NOT PROPERLY MOUNTED, THIS ALARM IS
INTFC (x) INPHASE: INDICATE THE STATUS OF THE RECEIVE SIGNAL FROM ISSUED
RADIO CH1 AND RADIO CH2 IN (1+1) CONFIGURATION. IF THE DELAY INTFC (x) MISMATCH: IF THE INTFC (x) CARD MOUNTED IS DIFFERENT FORM THE
BETWEEN THE TWO SIGNALS ARE NOT IN PHASE AT THE INPUT OF THE INTFC CARD CONFIGURED IN SETUP, THIS ALARM IS ISSUED.
HITLESS SWITCH, OUT PHASE IS INDICATED.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 23


MAIN INTFC DETAIL (GBE)
CLICK THE INTFC SYMBOL IN THE
BLOCK DIAGRAM OR THE INTFC
TAB IN THE DETAIL WINDOW TO
SEE THE INTFC ALARM AND
STATUS DETAIL

GBE

GbE LAN LINK PORT GbE LAN LINK FAILURE ALARM,

GbE SPEED & DUPLEX INDICATE THE STATUS OF GbE PORT SPEED & DUPLEX
SETTING.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 24


CTRL DETAIL
CLICK THE CTRL SYMBOL IN THE
BLOCK DIAGRAM OR THE CTRL
TAB IN THE DETAIL WINDOW TO
SEE THE CTRL CONTROLS AND APS CONFIGURATION
STATUS DETAIL APS SW FAIL INDICATE THE APS SWITCHING STATUS. WHEN THE APS SWITCHING
CONTROL IS APPLIED AND FAIL TO SWITCH, ALARM IS ISSUED
APS ONLINE STATUS INDICATE THE ONLINE INTFC OF THE APS SYSTEM IS
WORKING OR PROTECTION

XPIC CONFIGURATION

XCTRL INDICATE THE STATUS OF THE XPIC CONTROL SIGNAL BETWEEN MAIN
MASTER IDU AND SUB MASTER IDU. WHEN THE CONTROL SIGNAL FAILS ALARM IS
ISSUED

XPIC MODE MISMATCH INDICATE THE STATUS OF THE MAIN MASTER AND SUB
MASTER SETTING. IF BOTH IDUs ARE SET TO MAIN MASTER OR SUB MASTER THEN
ALARM IS ISSUED

CTRL DETAIL

CTRL MODULE INDICATE THE STATUS OF THE CTRL MODULE. WHEN A


FAILURE OCCURS, ALARM IS ISSUED

MMC MOUNT INDICATE THE STATUS OF THE MMC CARD SLOT. WHEN A
CARD IS MOUNTED INDICATE YES OTHERWISE NO.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 25


AUX I/O HOUSE KEEPING DETAIL
AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL
MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE PASOLINK
MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL
COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS ARE ALSO KNOWN AS
HOUSEKEEPING ALARMS AND CONTROLS.
HOUSE KEEPING ALARM INPUTS 3 TO 6 ARE SHARED WITH CLUSTER ALARM
INPUTS 1 TO 4. ONLY ONE CATEGORY OF INPUT SHOULD BE ASSIGNED.

CLICK THE AUX I/OUT SYMBOL IN THE BLOCK DIAGRAM OR THE AUX I/O TAB IN
THE DETAIL WINDOW TO SEE THE HOUSE KEEPING ALARM AND STATUS DETAIL

INPUT-X

CLICK ON ANY INPUT-X BUTTON TO OPEN THE INPUT-X CONFIGURATION SETTING


WINDOW
NAME: ENTER A NAME FOR THE ALARM ITEM UP TO 32 CHARACTERS. ENTERED
NAME APPEAR IN THE DETAIL WINDOW.

CONDITION: SELECT THE CONDITION FOR THE ALARM EVENT. ALARM WHEN EVENT IS
ON OR ALARM WHEN EVENT IS OFF. OR TO CONSIDER THIS EVENT AS A STATUS EVENT.
SELECT THE APPROPRIATE RADIO BUTTON

STATUS STRINGS: SELECT THE TEXT TO APPEAR ON THE STATUS FIELD IN THE DETAIL
WINDOW, WHEN THE EVENT ON AND THE EVENT OFF (UP TO 32 CHARACTERS)

X.733: ALARM INPUT SEVERITY IS DEFINED IN THE ITU-T X.733 RECOMMENDATIONS.


SELECT THE DESCRIPTION OF THE SEVERITY, ALARM TYPE AND PROBABLE CAUSE, BY
CLICKING THE DROP DOWN ARROW IN EACH FIELD.

CLICK EXECUTE BUTTON TO SAVE THE SETTINGS TO THE SELECTED INPUT

CLICK CLOSE BUTTON WHEN FINISHED TO EXIT THE WINDOW

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 26


AUX I/O CONTROL
UP TO 4 HOUSE KEEPING CONTROLS CAN BE CONFIGURED FOR EACH NE. THESE CONTROLS
ARE OUTPUT FROM THE RELAY OUTPUTS AVAILABLE FROM THE PARALLEL INTERFACE. THE
4 RELAYS USED ARE SHARED WITH CLUSTER ALARM OUTPUT 1 TO 4 AND ASSIGNED
PASOLINK ALARMS IN RELAY ASSIGNMENT IN PROVISIONING. MAKE SURE THAT WHEN
HOUSE KEEPING CONTROL IS ASSIGNED TO A RELAY THAT OTHER CATEGORIES ARE NOT
ASSIGNED

CLICK THE AUX I/OUT SYMBOL IN THE BLOCK


DIAGRAM OR THE AUX I/O TAB IN THE DETAIL
WINDOW TO SEE THE HOUSE KEEPING ALARM
AND STATUS DETAIL

OUTPUT-X SETUP

CLICK ON OUTPUT (X) BUTTON TO OPEN THE OUTPUT-X CONFIGURATION AND


CONTROL SETTING WINDOW
NAME: ENTER A NAME FOR THE CONTROL ITEM UP TO 32 CHARACTERS. ENTERED
NAME APPEAR IN THE DETAIL WINDOW.
DO NOT ASSIGN MORE
TEXT STRING TO APPEAR ON THE STATUS FIELD IN THE DETAIL WINDOW WHEN THE THAN ONE CATEGORY TO
CONTROL IS ON AND OFF CAN BE ENTERED HERE THE SAME RELAY AS
SHOWN
ENTER THE TEXT TO APPEAR WHEN THE EVENT IS ON ( CONTROL ON) AND WHEN THE
EVENT IS OFF (CONTROL OFF)

TO CONTROL THE EXTERNAL EQUIPMENT CONNECTED TO THIS OUTPUT SELECT:

SELECT EVENT ON RADIO BUTTON AND EXECUTE TO SET CONTROL ON

SELECT EVENT OFF RADIO BUTTON AND EXECUTE TO SET CONTROL OFF

CLICK CLOSE BUTTON WHEN FINISHED TO EXIT THE WINDOW

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 27


INVENTORY

172 .018. 000. 005

INVENTORY LIST SHOWS HARDWARE


AND SOFTWARE DETAILS OF EACH
MODULE INCLUDING THE CODE
NUMBER, SERIAL NUMBER AND
MANUFACTURE DATE
CLICK THE INVENTORY SYMBOL IN THE
BLOCK DIAGRAM OR THE INVENTORY
TAB IN THE DETAIL WINDOW TO SEE THE
INVENTORY LIST OF THE NE S
MODULES

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 28


ACTIVE ALARM LIST

CLICK ON THE ALARM LIST ICON


TO OPEN THE ALARM LIST
WINDOW. ALARM LIST WINDOW
SHOWS ALL THE ACTIVE ALARMS
IN THE NE

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 29


EQUIPMENT SETUP

USER INTERFACE
REDUNDANCY CONFIGURATION
MAIN / SUB INTERFACE
XPIC USAGE
APS FUNCTION
MODULATION
TRANSMISSION CAPACITY

TX / RX FREQUENCY
FRAME ID
TX POWER MODE
LAN PORT USAGE
LAN PORT SETTING

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 30


EQUIPMENT SETUP - 1
CLICK THE CONFIGURATION MENU IN NE SPECIFIC
MENU BAR AND SELECT EQUIPMENT SETUP

EQUIPMENT SETUP WINDOW SHOWS THE CURRENT CONFIGURATION OF THE


SELECTED NE

USER INTERFACE INDICATE USER INTERFACE TYPE USED

REDUNDANCY SETTING INDICATE THE REDUNDANCY CONFIGURATION USED

MAIN (WORK) INTFC (1) INDICATE THE INTERFACE PACKAGE USED FOR MAIN OR
INTERFACE SLOT (1) (FOR PDH CONFIGURATION ONLY MAIN INTFC
MODULATION SCHEME INDICATE MODULATION SCHEME USED

TRANSMISSION CAPACITY INDICATE THE TRANSMISSION CAPACITY USED

TX /RX RF FREQUENCY INDICATE THE TX AND RX FREQUENCIES USED

FRAME ID INDICATE THE FRAME ID USED

TX POWER CONTROL INDICATE THE TX POWER CONTROL MODE USED


LAN PORT USAGE INDICATE LAN PORT IS USED USAGE ,SHARED, SEPARATED
NOT USED
RADIO MAPPING INDICATE LAN TRAFFIC CAPACITIES

NE NAME INDICATE THE NAME ASSIGNED TO THE NE (CAN BE CHANGED FROM


PNMTx OR FROM NETCONFIGTOOL)
IP ADDRESS INDICATE THE IP ADDRESS ASSIGNED TO THE NE

OPPOSITE-1 IP ADDRESS INDICATE THE IP ADDRESS DETECTED FROM THE


OPPOSITE NE
NOTE INDICATE A MESSAGE MEANT FOR THE OPERATIONAL OR MAINTENANCE
STAFF (CAN BE CHANGED FROM PNMx OR FROM NETCONFIGTOOL)

BUTTON

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 31


EQUIPMENT SETUP - 2
NE name can be set form the
NetCfgTool and download the
config files to the NE. Later NE
NE NAME name can be changed from the
PNMx , this change is not reflected
in the NetCfgTool file. If you modify
the network using the NetCfgTool
and download modified config file
NE name change to the original
name.

1 NE NAME

CLICK THE NE NAME BUTTON IN THE EQUIPMENT


SETUP WINDOW TO OPEN THE NE NAME WINDOW
ENTER THE NEW NE NAME, UP TO 32 CHARACTERS.

CLICK THE EXECUTE BUTTON TO CHANGE THE NAME


CLICK THE CLOSE BUTTON TO EXIT WHEN FINISHED

2 NOTE

CLICK THE NOTE BUTTON IN THE EQUIPMENT SETUP


WINDOW TO OPEN THE NE NAME WINDOW
ENTER THE MESSAGE RELEVANT FOR THE NE FOR THE
1 OPERATING OR MAINTENANCE STAFF, UP TO 100
CHARACTERS.
CLICK THE EXECUTE BUTTON TO CHANGE THE NAME

CLICK THE CLOSE BUTTON TO EXIT WHEN FINISHED


2

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 32


SETUP WIZARD

SETUP: CLICK THE SETUP BUTTON


ON THE EQUIPMENT SETUP WINDOW
TO OPEN THE SETUP WIZARD

OPENING WINDOW OF THE EQUIPMENT SETUP


WINDOW SHOWS THE CURRENT SETUP IF ANY

TO CONFIGURE THE NETWORK ELEMENT, OR


CHANGE ANY PARAMETER IN THE CURRENT
SETUP CLICK THE CONFIGURE BUTTON

WHEN ANY PARAMETER IS CHANGED THE


EXECUTE BUTTON WILL BECOME ACTIVE.
CLICK THE EXECUTE BUTTON TO CARRY OUT
CLICK THE CONFIGURE BUTTON TO OPEN THE EQUIPMENT SETUP WIZARD THE CHANGES
CLICK THE EXECUTE BUTTON TO CARRY OUT ANY CHANGES MADE FROM THE EQUIPMENT SETUP WIZARD
TO CLOSE AND EXIT THE WIZARD CLICK THE
CLICK THE CLOSE BUTTON TO EXIT THE EQUIPMENT SETUP WINDOW CLOSE BUTTON

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 33


SETUP WIZARD
CLICK THE CONFIGURE BUTTON IN THE EQUIPMENT SETUP WINDOW

User
Interface:
Click the drop
down arrow
and select the
User Interface
Type to be
used

Redundancy Setting: Click the drop down arrow


and select the Redundancy method to be used.
Depends on the hardware configuration

Main (Work) INTFC(1): There are two ways of


selecting this.
The Inserted Module field shows the Interface
already mounted in the IDU. To select this click the
arrow to the left of this field. OR
Click the drop down arrow and select the Interface
Package available for the selected User Interface

SUB (PROT) INTFC(2): Interface (2) is used when


a SDH Interface is selected as the user interface
The Inserted Module field shows the Interface
already mounted in the IDU. To select this click the
arrow to the left of this field. OR
Click the drop down arrow and select the Interface AFTER SETTING THE PARAMETERS CLICK THE
Package available for the selected User Interface NEXT BUTTON

TO GO BACK TO THE PREVIOUS SETTING


APS Function When an Optical interface is XPIC Usage): select whether XPIC function is
SCREEN CLICK THE BACK BUTTON
mounted in the SUB (PROT) slot select whether used or not. If used select whether the IDU is to be
APS function is available or Un avilabel used as Master or Sub Master TO CANCEL AND EXIT THE WIZARD CLICK THE
CANCEL BUTTON

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 34


SETUP WIZARD

Modulation scheme: click the drop down arrow and


select the modulation scheme to use
Transmission Capacity: click the drop down arrow
and select the transmission Capacity to use.
Selection depends on the modulation scheme
selected
Frequency setting- Depends on the redundancy
setting. If (1+0) only No. 1 is available
Upper / lower: Indicate that the ODU connected is of
Upper or Lower Frequency band
TX Start Frequency: Indicate that the Start Frequency of
the TX sub band
TX Stop Frequency: Indicate that the stop Frequency
of the TX sub band
RX Start Frequency: Indicate that the Start Frequency
of the RX sub band
RX Stop Frequency: Indicate that the stop Frequency
of the RX sub band
TX RF Frequency: Enter the point frequency within the
Start and Stop frequency (see the frequency tables)
RX RF Frequency: Rx frequency is automatically
entered according to the shift frequency
Shift Frequency: indicate the ODU shift frequency

Frequency Channel: Select the frequency from a


preset frequency table
Frame ID: enter the Frame ID to be used. Should be
the same value for both sides of the radio link.. AFTER SETTING THE PARAMETERS CLICK THE
NEXT BUTTON
TX Power Control : select the TX power control mode
MTPC or ATPC
TO GO BACK TO THE PREVIOUS SETTING
QPSK 16 QAM 32 QAM 128 QAM
SCREEN CLICK THE BACK BUTTON
Frequency setting- Depends on the redundancy setting. If 40 MB 40 MB
(1+0) only No.1 is available TO CANCEL AND EXIT THE WIZARD CLICK THE
80 MB 100 MB 156 MB
If (1+1) Hot Standby No. 1 or No 2 depending on which one CANCEL BUTTON
is online
If (1+1) Twin path ,both No.1 and No.2

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 35


SETUP WIZARD FREQUENCY CHANNEL
TX AND RX FREQUENCY CAN BE SELECTED FROM PRE-SET TABLE.

CLICK ON THE FREQUENCY CHANNEL BUTTON.


CLICK BROWSE BUTTON AND SELECT WHERE THE
FREQUENCY TABLE FILE IS LOCATED
FROM THE CHANNEL PLAN LIST SELECT THE FREQUENCY
CHANNEL TO ASSIGN

CLICK OK TO ASSIGN THE FREQUENCY

SAVE AS A CSV FILE

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 36


SETUP WIZARD

LAN Port Usage: click the drop down arrow and select the
LAN port used or not. If used for Main traffic or Service
channel (selection depend on the interface card used)

Radio Mapping: click the drop down arrow and select the
transmission capacity to be used for LAN traffic. Balance of
the transmission capacity is used for E1 traffic

2M (E1) Assignment: when transmission capacity for LAN


is selected for main traffic, the number of E1 channels
available is indicated here.

LAN PORT USAGE (2 PORT LAN) REPEATER

PORT 1-2 SHARED / 1 PORT ONLY (DIR-A M)

PORT 1-2 SHARED / 1 PORT ONLY (DIR-B M)

PORT 1-2 SHARED / 1 PORT ONLY (DIR-A SC)

PORT 1-2 SHARED / 1 PORT ONLY (DIR-B SC)

Port 1-2 Star (DIR-A M, Dir-B M)

Port 1-2 Star (DIR-A M, Dir-B SC)

Port 1-2 Star (DIR-A SC, Dir-B M)

Port 1-2 Star (DIR-A SC, Dir-B SC)

Port 1-2 Mixed (DIR-A M, Dir-B M)

Port 1-2 Mixed (DIR-A M, Dir-B SC)

Port 1-2 Mixed (DIR-A SC, Dir-B M)


AFTER SETTING THE PARAMETERS TO GO BACK TO THE PREVIOUS SETTING TO CANCEL AND EXIT THE WIZARD
Port 1-2 Mixed (DIR-A SC, Dir-B SC) CLICK THE NEXT BUTTON SCREEN CLICK THE BACK BUTTON CLICK THE CANCEL BUTTON
NOT USED

LAN PORT USAGE (2 PORT LAN) LAN PORT USAGE (4 PORT LAN) LAN PORT USAGE (PDH E3 WITH 2 PORT LAN)

PORT 1-2 SHARED / 1 PORT ONLY (MAIN) PORT 1-4 SHARED (MAIN) PORT 1 2 SHARED / 1 PORT ONLY (SC)

PORT 1-2 SEPARATED (MAIN) PORT 1 2 SHARED / PORT 3-4 SHARED (MAIN) PORT 1 2 SHARED / 1 PORT ONLY (WS)

PORT 1 2 SHARED / 1 PORT ONLY (SC) PORT 1-4 SEPARATED (MAIN) NOT USED

NOT USED NOT USED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 37


SETUP WIZARD

1 AFTER COMPLETING THE EQUIPMENT SETUP WIZARD CLICK


THE FINISH BUTTON. WINDOW RETURNS TO THE EQUIPMENT
SETUP MAIN WINDOW.

2 VERIFY THE SETTINGS CAREFULLY, CONFIRM THAT THE


SETTINGS ARE CORRECT. THE EXECUTE BUTTON IS ACTIVE IN
THE EQUIPMENT SETUP WINDOW AND CAN BE CLICKED TO
ACTIVATE THE SETUP PARAMETERS. IF THE WINDOW IS Execute
CLOSED WITHOUT EXECUTING, THE PARAMETERS WILL NOT BE
ACTIVATED. 2

TO EXIT THE EQUIPMENT SETUP WINDOW


CLICK THE CLOSE BUTTON.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 38


SETUP WIZARD

1 AFTER COMPLETING THE EQUIPMENT SETUP WIZARD CLICK


THE FINISH BUTTON. WINDOW RETURNS TO THE EQUIPMENT
SETUP MAIN WINDOW.

2 VERIFY THE SETTINGS CAREFULLY, CONFIRM THAT THE


SETTINGS ARE CORRECT. THE EXECUTE BUTTON IS ACTIVE IN 2
THE EQUIPMENT SETUP WINDOW AND CAN BE CLICKED TO
ACTIVATE THE SETUP PARAMETERS. IF THE WINDOW IS
CLOSED WITHOUT EXECUTING, THE PARAMETERS WILL NOT BE
ACTIVATED.

TO EXIT THE EQUIPMENT SETUP WINDOW


CLICK THE CLOSE BUTTON.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 39


PROVISIONING
PDH ONLY COMMON TO PDH / SDH

CHANNEL USAGE HIGH BER THRESHOLD


CHANNEL USAGE ERROR REPORT LOW BER THRESHOLD
AIS ACTIVATION CONDITION SC SETTING RS -232C
AIS GENERATED REPORT SC SETTING V.11
AIS RECEIVED REPORT SC SETTING V.11 DIRECTION
AIS RECEIVED CONDITION MTPC TX POWER
ATPC RX THRESHOLD
E1 PORT IMPEDANCE
ATPC TX POWER RANGE
XC FUNCTION & CH SETTING
ADDITIONAL ATTENUATION
SDH ONLY ATPC POWER MODE
TX/ RX SW PRIORITY
EXCESSIVE BER (DMR/MUX)
RX SW MAINTENANCE MODE
SIGNAL DEGRADE (DMR / MUX)
MS AIS GENERATION RX SW CONDITION - EW

AUTOMATIC LASER SHUTDOWN RELAY CONFIGURATION

AUTOMATIC PROTECTION SWITCHING CLUSTER ALARM INPUT


SES ACTIVATION
ALARM CORRELATION
RX LEV TCN THRESHOLD

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 40


PROVISIONING CHANNEL SETTING

DIR-A AND DIR-B IS SHOWN FOR


REPEATER CONFIGURATION

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 41


PROVISIONING CHANNEL SETTING

CLICK ANY ONE OF THE CH RELATED


BUTTONS ON THE PROVISIONING
WINDOW TO OPEN THE CHANNEL
SETTING WINDOW

CH USAGE (CH#)

CLICK ON THE CHECK BOXES TO SELECT


THE E1 CHANNEL TO BE USED

E1 PORT IMPEDANCE

SELECT THE IMPEDANCE FOR EACH


CHANNEL . SELECT 75 OHM OR 120 OHM
RADIO BUTTON FOR EACH CHANNEL

ALL CLEAR THIS BUTTON CLEAR ALL


SETTINGS. CLICK THE EXECUTE BUTTON TO APPLY
THE CHANNEL SETTINGS

ALL SELECT- THIS BUTTON SELECT ALL CLICK THE CLOSE BUTTON TO EXIT WHEN
CHANNELS IN THE CHANNEL USAGE. FINISHED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 42


PROVISIONING CHANNEL SETTING

CLICK ANY ONE OF THE CH RELATED


BUTTONS ON THE PROVISIONING
WINDOW TO OPEN THE CHANNEL
SETTING WINDOW

AIS ACTIVATION CONDITION

SELECT WHETHER LOF + HBER OR ONLY


LOF TO BE CONSIDERED AS THE AIS
ACTIVATION CONDITION
AIS GENERATION REPORT
AIS RECEIVED REPORT
SELECT WHETHER TO REPORT OR NOT CLICK THE EXECUTE BUTTON TO APPLY
SELECT WHETHER TO REPORT OR NOT REPORT THE AIS GENERATED CONDITION. THE CHANNEL SETTINGS
REPORT THE AIS RECEIVED CONDITION. WHEN NOT REPORT IS SELECTED AIS
WHEN NOT REPORT IS SELECTED AIS GENERATION CONDITION IS IGNORED CLICK THE CLOSE BUTTON TO EXIT WHEN
RECEIVED CONDITION IS IGNORED FINISHED
CH USAGE ERROR REPORT
AIS RECEIVED CONDITION
WHEN AN E1 SIGNAL IS DETECTED AT THE
SELECT WHETHER THE AIS RECEIVED INPUT OF A CHANNEL SET AS NOT USED,
CONDITION IS TO BE CONSIDERED AS AN WHETHER TO REPORT THIS AS AN ALARM
ALARM EVENT OR AS A STATUS EVENT EVENT OR NOT

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 43


PROVISIONING BER THRESHOLD SETTING

CLICK ANY ONE OF THE BER RELATED


BUTTONS ON THE PROVISIONING
WINDOW TO OPEN THE BER THRESHOLD
SETTING WINDOW

FOR EACH BER THRESHOLD


SETTING, THE RADIO BUTTONS
SHOWS THE AVAILABLE
SETTING RANGE

FOR PDH AND SDH CONFIGURATION FOR SDH CONFIGURATION


ONLY
HIGH BER THRESHOLD
E-BER (DMR)
SELECT THE HBER THRESHOLD FOR THE RADIO
LINK.. CLICK THE APPROPRIATE RADIO BUTTON EXCESSIVE BER THRESHOLD SETTING
FOR THE STM-1 SIGNAL RECEIVED FROM
LOW BER THRESHOLD THE RADIO DIRECTION

SELECT THE LBER THRESHOLD FOR THE RADIO SD (DMR)


LINK.. CLICK THE APPROPRIATE RADIO BUTTON
SELECT THE SIGNAL DEGRADE THRESHOLD
SETTING FOR THE STM-1 SIGNAL RECEIVED
FROM THE RADIO DIRECTION
CLICK THE EXECUTE BUTTON TO
E-BER (MUX) APPLY THE CHANNEL SETTINGS
CLICK THE CLOSE BUTTON TO EXIT
EXCESSIVE BER THRESHOLD SETTING WHEN FINISHED
FOR THE STM-1 SIGNAL RECEIVED FROM
THE MUX DIRECTION

SD (MUX)

SELECT THE SIGNAL DEGRADE THRESHOLD


SETTING FOR THE STM-1 SIGNAL RECEIVED
PDH REPEATER CONFIGURATION DIR-A & DIR-B CAN BE SET FROM THE MUX DIRECTION

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 44


PROVISIONING TX POWER CONTROL
CLICK ANY ONE OF THE TX POWER RELATED BUTTONS ON THE PROVISIONING
WINDOW TO OPEN THE TX POWER CONTROL SETTING WINDOW. ACTIVE FIELDS
DEPEND ON THE TX POWER CONTROL MODE SELECTED, ATPC OR MTPC

MTPC TX POWER

THIS CONTROL SELECT MTPC POWER LEVEL WHEN


MTPC MODE IS SELECTED IN EQUIPMENT SETUP
ENTER THE ATTENUATION IN MINUS dB FROM THE
ODU NOMINAL POWER TO SET THE FIXED TX POWER.

ATPC TX POWER

THIS CONTROL SELECT ATPC POWER SETTING WHEN


ATPC MODE IS SELECTED IN EQUIPMENT SETUP
(1+1) CONFIGURATION) NO.1. AND NO..2IS INDICATED
ATPC RANGE DEFINES THE MAXIMUM AND MINIMUM
REPEATER CONFIGURATION DIR-A/DIR-B IS INDICATED
TRANSMISSION POWER DURING ATPC OPERATION. IN
ADDITIONAL ATT
MTPC MODE THIS MENU ITEMS DOES NOT APPEAR.
5 dB ADDITIONAL ATTENUATION IS AVAILABLE FOR 32 QAM
VALUE SET IS THE ATTENUATION IN dB FROM MAX AND 128 QAM FOR SOME OF THE FREQUENCY BANDS
ODU POWER.
ENTER THE ATTENUATION IN MINUS dB FROM 1 5 dB.
SET THE VALUES FOR ATPC RANGE (MAX) AND
ATPC RANGE (MIN).
ATPC RECEIVE THRESHOLD
ATPC POWER MODE DEFINES WHAT SHOULD BE THE
TX POWER WHEN ATPC CONTROL SIGNAL FAIL THIS RECEIVE THRESHOLD LEVEL TRIGGERS THE ATPC
CONTROL IN THE OPPOSITE STATION
SELECTION IS, WHEN ATPC CONTROL FAIL SET THE
TX POWER TO MAX ATPC LEVEL, OR SET THE TX ENTER THE ATPC RX THRESHOLD LEVEL IN MINUS dBm.
POWER MIN ATPC LEVEL OR HOLD AT THE CURRENT
ATPC POWER LEVEL CLICK THE EXECUTE BUTTON TO CHANGE THE NAME
CLICK THE CLOSE BUTTON TO EXIT WHEN FINISHED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 45


PROVISIONING TX POWER CONTROL

ATPC POWER MODE

ATPC POWER MODE DEFINES WHAT SHOULD BE THE


TX POWER WHEN ATPC CONTROL SIGNAL FAIL

SELECTION IS, WHEN ATPC CONTROL FAIL SET THE


TX POWER TO MAX ATPC LEVEL, OR SET THE TX
POWER MIN ATPC LEVEL OR HOLD AT THE CURRENT
ATPC POWER LEVEL

COMM ALARM MODE

COMM ALARM MODE SETTING DEFINES WHAT


SHOULD BE THE ODU OUTPUT MODE WHEN THE
COMMUNICATION BETWEEN IDU AND ODU FAILS.

SELECTION IS, WHEN COMMUNICATION FAILS HOLD


AT THE CURRENT ATPC POWER LEVEL OR MUTE THE
OUTPUT.
SELECT THE APPROPRIATE RADIO BUTTON.

CLICK THE EXECUTE BUTTON TO CHANGE THE NAME

CLICK THE CLOSE BUTTON TO EXIT WHEN FINISHED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 46


PROVISIONING -SWITCHING CONDITION (TX)

CLICK ANY ONE OF THE SW RELATED


BUTTONS ON THE PROVISIONING
WINDOW TO OPEN THE SW CONDITION
SETTING WINDOW

TX SW - PRIORITY

THIS CONTROL SELECT PRIORITY CH SELECTION FOR TX SWITCHING.


SELECT PRIORITY NO1 .TO USE CH 1 AS TX CHANNEL WHEN CH1 IS NORMAL (HOMING SWITCHING
OR REVERTIVE SWITCHING) AND SWITCHING IS AUTO MODE. WHEN A FAULT OCCUR CH1 SW TO
CH2 . WHEN CH1 IS NORMAL TRAFFIC RETURNS TO CH1 AUTOMATICALLY.
SELECT NON PRIORITY .FOR NON-HOMING OR NON REVERTIVE SWITCHING

LOCK IN USAGE

THIS FUNCTION APPLIES TO 1+1 HOT STANDBY CONFIGURATION WITH TX SWITCH SET TO PRIORITY
NO.1

IN THE CASE WHEN DUE TO INTERMITTENT ODU1 FAILURE IT SWITCHES FROM ODU1 TO ODU2 AND
BACK TO ODU1 REPEATEDLY AND LOCK IN USAGE IS SELECTED USED, TX SWITCH WILL BE LOCKED
TO ODU2 TO PREVENT FREQUENT SWITCHING.

REVERSE FUNCTION

THIS FUNCTION APPLIES TO 1+1 HOT STANDBY CONFIGURATION WITH TX SWITCH SET TO NON
CLICK THE EXECUTE BUTTON TO CHANGE
PRIORITY.
THE NAME
WHEN BOTH RECEIVE FAILS DUE TO OPPOSITE STATION TX MAIN ANTENNA MISALIGNMENT, AND
CLICK THE CLOSE BUTTON TO EXIT WHEN
REVERSE FUNCTION IS SET TO USED, THEN SENDS A SILENT ALARM TO TX SIDE TO SWITCH TX ODU
FINISHED
TO STANDBY ODU.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 47


PROVISIONING -SWITCHING CONDITION (RX)

CLICK ANY ONE OF THE SW RELATED


BUTTONS ON THE PROVISIONING
WINDOW TO OPEN THE SW CONDITION
SETTING WINDOW

RX SW - PRIORITY

THIS CONTROL SELECT PRIORITY CH SELECTION FOR RX SWITCHING.


SELECT PRIORITY NO1 .TO USE CH 1 AS RX CHANNEL WHEN CH1 IS NORMAL (HOMING SWITCHING
OR REVERTIVE SWITCHING) AND SWITCHING IS AUTO MODE. WHEN A FAULT OCCUR CH1 SW TO
CH2 . WHEN CH1 IS NORMAL TRAFFIC RETURNS TO CH1 AUTOMATICALLY
SELECT NON PRIORITY .FOR NON-HOMING OR NON REVERTIVE SWITCHING

RX SW MAINTENANCE MODE

THIS CONTROL SELECT THE MANUAL SWITCHING CONDITION UNDER MAINTENANCE MODE
SELECT MANUAL RADIO BUTTON, TO PREVENT MANUAL SWITCHING WHEN EITHER CH1 OR CH2 IS IN
ALARM CONDITION
SELECT FORCED RADIO BUTTON, TO FORCIBLY SWITCH WHEN EITHER CH1 OR CH2 IS IN ALARM
CONDITION

RX SW CONDITION-EARLY WARNING
CLICK THE EXECUTE BUTTON TO CHANGE
THIS CONTROL SELECT WHETHER TO USE EARLY WARNING (EW) AS A CRITERIA FOR RX SWITCHING
THE NAME
SELECT INCLUDE EW RADIO BUTTON, TO USE EW AS A SWITCHING CRITERIA. SELECT EXCLUDE EW
RADIO BUTTON, NOT TO CONSIDER EW AS RX SW CRITERIA CLICK THE CLOSE BUTTON TO EXIT WHEN
FINISHED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 48


PROVISIONING RELAY CONFIGURATION
PASOLINK NEO IDU HAS 6 RELAYS WHICH CAN BE
ASSIGNED TO OUTPUT PASOLINK ALARMS, CLUSTER
ALARM OUTPUT AND HOUSEKEEPING ALARMS. RELAY 1
AND 2 ASSIGNMENTS ARE FIXED AND CANNOT BE
CHANGED. EACH RELAY 3, 4, 5 AND 6 CAN BE ASSIGNED
TO OUT PUT ON OF THE FOLLOWING, HOUSE KEEPING A: HOUSE KEEPING
CONTROL OUT OR CLUSTER ALM OUT OR PASOLINK A CONTROL SETTING
ALARM OUT.
B: CLUSTER ALARM
B OUTPUT SETTING

C: PASOLINK
ALARM RELAY
ASSIGNMENT FOR
CLICK ON A BUTTON TO PARALLEL ALARM
ASSIGN TO RELAY OUTPUT

C
CLICK THE BUTTON RELAY CONFIGURATION TO OPEN THE
RELAY CONFIGURATION WINDOW

PASOLINK ALARMS

CLICK THE BUTTON CROSSING THE ALARM ROW AND THE


CLICK THE EXECUTE BUTTON TO APPLY THE CHANNEL SETTINGS
RELAY COLUMN TO ASSIGN THAT ALARM TO BE OUT PUT
FROM THAT RELAY. IT IS POSSIBLE TO ASSIGN MULTIPLE
ALARMS TO THE SAME RELAY AND ASSIGN THE SAME ALARM CLICK THE CLOSE BUTTON TO EXIT WHEN FINISHED
TO MULTIPLE RELAYS.

HOUSE KEEPING CONTROL

CLICK THE BUTTON CROSSING THE HK CONTROL AND THE


IMPORTANT: FOR EACH RELAY, SELECT FROM ONE CATEGORY ONLY
RELAY COLUMN TO ASSIGN THAT CONTROL TO BE OUT PUT
( FROM A OR B OR C)
FROM THAT RELAY.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 49


PROVISIONING CLUSTER ALARM
CLUSTER ALARM ARE EXTERNAL ALARMS THAT IS INPUT
IN ONE STATION AND TAKEN OUT FROM THE PARALLEL
INTFC IN THE OPPOSITE STATION.

A: HOUSE KEEPING
CONTROL SETTING

B: CLUSTER ALARM
OUTPUT SETTING

C: PASOLINK
ALARM RELAY
ASSIGNMENT FOR
CLICK ON A BUTTON TO PARALLEL ALARM
ASSIGN TO RELAY OUTPUT

CLUSTER ALARM INPUT

CLICK THE ENABLE RADIO BUTTON TO ENABLE THE SELECTED


CLUSTER ALARM INPUT.
CLICK THE EXECUTE
BUTTON TO APPLY THE
CHANNEL SETTINGS IN THE OPPOSITE STATION SELECT RELAY CONFIGURATION FROM THE
PROVISIONING MENU. ASSIGN CLUSTER ALARM OUT FOR THE
SELECTED CLUSTER ALARM INPUT. REMOVE ANY OTHER ASSIGNMENT
CLICK THE CLOSE
TO THAT RELAY (PASOLINK ALARMS OR HK CONTROLS)
BUTTON TO EXIT WHEN
FINISHED
IMPORTANT: FOR EACH RELAY, SELECT FROM ONE CATEGORY ONLY ( FROM A OR B OR C)

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 50


PROVISIONING COMMON
CLICK THE BUTTONS RX LEVEL TCN THRESHOLD OR SES ACTIVATION
TO OPEN THE PMON SELECT WINDOW

CLICK THE BUTTONS ALARM CORRELATION CAPABILITY


OPEN THE ALARM CORRELATION CAPABILITY WINDOW

ABOVE IS FOR (1+1) CONFIGURATION, (1+0) NO. 2 IS NOT SHOWN

REPEATER
SETTING

ALARM CORRELATION CAPABILITY

THIS SETTING IS TO FILTER THE ALARMS AND GIVE THE MAIN


(ROOT) CAUSE OF THE ALARM . SELECT THE APPROPRIATE
RADIO BUTTON
OFF : CORRELATION OFF GIVES THE MAIN ALARM AS WELL AS RX LEVEL IS MEASURED EVERY 15 MIN AND THE MAX AND MIN VALUE ARE
THE SECONDARY ALARMS GIVEN AS PMON ITEM. ENTER THE RX LEVEL THRESHOLD FOR TCN ALARM.
NORMAL: CORRELATION ON, GIVES MAIN CAUSE OF THE
FAILURE SES ACTIVATION CONDITION

SELECT THE APPROPRIATE RADIO BUTTON 15 % OR 30 % FOR


CLICK THE EXECUTE BUTTON TO APPLY THE CHANNEL SETTINGS PERCENTAGE OF BLOCKS IN ERROR FOR SES ACTIVATION

CLICK THE CLOSE BUTTON TO EXIT WHEN FINISHED CLICK THE EXECUTE BUTTON TO APPLY THE CHANNEL SETTINGS
CLICK THE CLOSE BUTTON TO EXIT WHEN FINISHED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 51


PROVISIONING E0W2 EXTERNAL SETTING

CLICK THE EOW2 EXTERNAL SETTING BUTTON ON THE


PROVISIONING WINDOW TO OPEN THE EOW2 EXTERNAL
SETTING WINDOW

EOW2 EXTERNAL SETTING

THIS SETTING IS FOR BACK TO BACK CONNECTION OF ENGINEERING ORDER WIRE


CALLING SIGNAL BETWEEN DIFFERENT TYPES OF PASOLINK EQUIPMENT.
SELECT THE APPROPRIATE RADIO BUTTON:
INVERT : SELECT THIS FOR CONNECTION BETWEEN PASOLINK+ / MX IDU & NEO IDU
NORMAL: SELECT THIS FOR CONNECTION BETWEEN PASOLINK IDU & NEO IDU

CLICK THE EXECUTE BUTTON TO APPLY


THE CHANNEL SETTINGS

CLICK THE CLOSE BUTTON TO EXIT WHEN


FINISHED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 52


PROVISIONING LAN SETTING
CLICK ANY BUTTON OF THE LAN PROVISIONING ITEMS IN
THE PROVISIONING WINDOW TO OPEN THE LAN PORT
SETTING WINDOW

LAN PORT SETTING

SWITCHING FUNCTION: CLICK THE SWITCHING


FUNCTION DROPDOWN ARROW AND SELECT ENABLE
OR DISABLE
FOR EACH PORT SELECT:
PORT USAGE: USED OR NOT USED
SPEED & DUPLEX : SET THE SPEED & DUPLEX SETTING
ACCORDING TO THE EXTERNAL EQUIPMENT SETTING
FLOW CONTROL : ON OR OFF
COLLISION REPORT : NOT REPORT OR REPORT
LINK LOSS FORWARDING: ACTIVE ONLY WHEN
SWITCHING FUNCTION IS SET TO DISABLE. SELECT
DISABLE OR ENABLE.
CLICK THE EXECUTE BUTTON TO APPLY
2M FRAMING: THIS IS ACTIVE ONLY WHEN LAN PORT THE CHANNEL SETTINGS
CAPACITY IS 2 MB. THEN SELECT FRAMING ATTRIBUTE
USED FROM THE DROP DOWN LIST. (See next page) CLICK THE CLOSE BUTTON TO EXIT WHEN
FINISHED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO/c 53


ETHER OVER E1
E1 NETWORKING

G732 Frame Structure


32TS:256bits/125us
8bit

Framing & CRC etc. Signaling CH


Multi frame structure Channel Associated Signaling(CAS)
Multi frame structure

Framing CRC CAS Type Description


Off Unframed All data bits are multiplexed
On Off Off PCM-31 All data multiplexed except TS0, no CRC
On On Off PCM-31C All data multiplexed except TS0,CRC yes
On Off On PCM-30 All data multiplexed except TS0/TS16, no CRC
On On On PCM-30C All data multiplexed except TS0/TS16, CRC yes

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO/c 54


PROVISIONING LAN PORT SETTING (GbE)
CLICK ANY ONE OF THE GbE RELATED
BUTTONS ON THE PROVISIONING
WINDOW TO OPEN THE LAN PORT
SETTING (GbE) WINDOW

USAGE

THIS IS SET TO USED AND CANNOT BE CHANGED. (MAIN


INTFC IS GbE AND IS ALWAYS USED)

MEDIA TYPE

GbE INTFC HAS TWO TYPE OF PORTS ELECTRICAL (RJ-45)


OR OPTICAL (SFP). SELECT THE MEDIA TYPE FROM THE
DROP DOWN LIST.

SPEED & DUPLEX

FOR GbE INTFC THIS IS ALWAYS SET TO AUTONEG (Auto


1000m Full). CANNOT BE CHANGED

FLOW CONTROL

SELECT FLOW CONTROL ON OR OFF

LINK LOSS FORWARDING

SELECT LINK LOSS FORWARDING FUNCTION ENABLE OR


DISABLE

CLICK THE EXECUTE BUTTON TO APPLY THE CHANNEL


SETTINGS

CLICK THE CLOSE BUTTON TO EXIT WHEN FINISHED

Link Loss Forwarding

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO HP 55


PROVISIONING LAN PORT SETTING (LAN/WS)
WHEN LAN/WS INTFC IS USED IN THE MAIN SLOT,
LAN PORT SETTING (MAIN) SHOULD BE SET.
WHEN LAN/WS INTFC IS USED IN THE SUB SLOT,
LAN PORT SETTING (SUB) SHOULD BE SET.

USAGE

SELECT WHETHER LAN PORT1 AND PORT 2 ARE


USED OR NOT. SELECT FROM THE DROP DOWN
LIST FOR EACH PORT.

FLOW CONTROL

SET THE FLOW CONTROL FOR EACH PORT.


SELECT FROM THE DROPDOWN LIST FLOW
CONTROL ON OR OFF

COLLISION REPORT

IN HALF DUPLEX MODE, SELECT WHETHER TO


CONSIDER COLLISION CONDITION AS AN ALARM
EVENT. SELECT REPORT OR NOT REPORT FROM
THE DROP DOWN LIST

LINK LOSS FORWARDING

SELECT WHETHER THE LINK LOSS FORWARDING


FUNCTION IS APPLIED OR NOT. FROM THE DROP
DOWN LIST SELECT ENABLE OR DISABLE

SPEED & DUPLEX

SET THE SPEED & DUPLEX FOR EACH PORT. SET


ACCORDING TO THE EXTERNAL EQUIPMENT
SETTING. SEE THE TABLE

CLOCK SOURCE SETTING CLICK THE EXECUTE BUTTON TO APPLY


THE CHANNEL SETTINGS
IN INTFC (MAIN) SETTING, SELECT THE CLOCK
SOURCE USED BY THE LAN PORT. SELECT CLICK THE CLOSE BUTTON TO EXIT WHEN
INTERNAL CLOCK OR DMR >>INTERNAL CLOCK FINISHED
(USE DMR CLOCK IF IT FAILS USE INTERNAL
CLOCK)

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 56


PROVISIONING SERVICE CHANNELS
CLICK ANY ONE OF THE SC RELATED
BUTTONS ON THE PROVISIONING
WINDOW TO OPEN THE SC ASSIGNMENT
SETTING WINDOW

V.11 & RS-232C E1 (MUX) E1 (DMR) E1 (MUX)


S V.11 & RS-232C F1 (MUX) F1 (DMR) F1 (MUX)
D V.11 DCCr (MUX) DCCr (DMR) DCCr (MUX)
V.11 & RS-232C DSC1 TO 4
H SC LAN DSC1 TO 4

SC ASSIGNMENT
CLICK THE EXECUTE BUTTON TO APPLY
TWO V.11 & TWO RS232 USER CHANNELS CAN BE ASSIGNED TO DSC 1 TO 4 IN THE THE CHANNEL SETTINGS
RFCOH OR THEY CAN BE ASSIGNED TO E1, F1 & DCCr BYTES IN THE RSOH IN THE
DIRECTION OF MUX OR RADIO (DMR). CLICK THE CLOSE BUTTON TO EXIT WHEN
CLICK ON THE BUTTONS TO ASSIGN USER CH TO SC OR RSOH BYTES. WHEN V.11 CH FINISHED
IS USED SELECT THE DIRECTION SETTING FROM THE APPROPRIATE RADIO BUTTON
SC LAN IS ASSIGNED FROM THE EQUIPMENT SETUP

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 57


PROVISIONING- SC REPEATER

THERE ARE TWO RS-232C CHANNELS , TWO V11 CHANNELS


AND OPTIONAL LAN PORT AVAILABLE IN PASOLINK NEO
EQUIPMENT. IT IS POSSIBLE TO ASSIGN THESE CHANNELS
TO ANY OF THE 4 DSC CH IN THE RFCOH AND 6 CH IN THE
SDH RSOH. THE ASSIGNMENT OF THESE CHANNELS CAN
BE CUSTOMIZE BY THE USER OR USE THE FACTORY
DEFAULT.... . IN THE CASE OF REPEATER RS232C, V.11 AND
SC LAN CAN BE SENT IN DIR-A OR DIR-B

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 58


PROVISIONING SC SETTING NEOi/c

SC LAN Not Used SC LAN Used = 64kbps


Possible Selections

SC LAN Used = 128kbps SC LAN Used = 256kbps

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO/c 59


PROVISIONING STM-1
CLICK MS-AIS GENERATION BUTTON TO OPEN THE MS-AIS GENERATION SETTING WINDOW.

MS AIS GENERATION

IN THE NEO STM-1 EQUIPMENT, WHEN THERE IS NO STM-1 INPUT OR ANY FAULT IN THE
RADIO SECTION, OR FOR ANY FAULT IN THE PASOLINK EQUIPMENT, MS-AIS IS OUT PUT TO
THE MUX EQUIPMENT.
THIS FUNCTION CAN BE ENABLED OR DISABLED FROM THIS PROVISIONING ITEM.

CLICK ON THE MS-AIS GENERATION BUTTON IN THE PROVISIONING WINDOW..

SELECT THE RADIO BUTTON MS-AIS GENERATION ENABLE TO SEND MS-AIS TO MUX WHEN
THERE IS FAILURE IN THE RX PATH.

SELECT THE RADIO BUTTON MS-AIS GENERATION DISABLE TO SEND UNFRAMED AIS TO MUX
WHEN THERE IS FAILURE IN THE RX PATH. IF THE INTFC IS OPTICAL, IT WILL SHUT DOWN THE
OUTPUT.
CLICK ON THE EXECUTE BUTTON TO APPLY THE SETTING.

STATION-A STATION-B

PASOLINK PLUS
MODEM STM-1
MODEM OUTPUT
STM-1 RFCOH RFCOH STM-1
MUX X INTFC MUX
ODU ODU FSYNC
DEMUX INTFC
MUX
INPUT
LOSS STM-1
STM-1
RLOS RLOS LOF
LOF OUTPUT
RLOF RLOF CONTROL
LOS
LOF

CLICK THE CLOSE BUTTON TO EXIT WHEN STATION-A STATION-B


EVENT LED LCT LED LCT STM-1 OUTPUT
FINISHED
STM-1 OUTPUT CONTROL
STM-1 Input Loss at station-A IDU ALM MAIN INTFC LOS -- UNDER EXECUTION AIS/SHUTDOWN

STM-1 L0ss of Frame at station-A IDU ALM MAIN INTFC LOF -- UNDER EXECUTION AIS/SHUTDOWN
CLICK THE EXECUTE BUTTON TO APPLY
RX Level down at station-B -- ODU ALM UNDER EXECUTION AIS/SHUTDOWN
THE CHANNEL SETTINGS
Loss of radio frame at station-B -- IDU ALM UNDER EXECUTION AIS/SHUTDOWN

BER at station B (<= 1 E-4) -- IDU ALM NORMAL N/A

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 60


PROVISIONING APS CONDITION
APS SW CONDITION

THIS PROVISIONING ITEMS ARE AVAILABLE


WHEN TWO OPTICAL INTFC ARE MOUNTED FOR
APS OPERATION.

SELECT ANY ONE OF THE APS RELATED


PROVISIONING BUTTONS TO SET THE SW
CONDITIONS FOR APS OPERATION
SET THE SW CONDITIONS FOR APS BY
SELECTING THE APPROPRIATE RADIO BUTTON
OR ENTERING A VALUE.

AFTER COMPLETING THE SW CONDITION


SETTING, CLICK THE EXECUTE BUTTON TO
APPLY THE SETTING.

CLICK THE CLOSE BUTTON TO EXIT THE SW


CONDITION (APS) PROVISIONING WINDOW.

APS MAINTENANCE MODE


SET THE PRIORITY SETTING FOR MANUAL APS OPERATION UNDER MAINTENANCE
MANUAL: WHEN SELECTED, PREVENT MANUALLY SWITCHING TO AN ALARMED INTFC EITHER WORKING OR
PROTECTION.
FORCED: WHEN SELECTED, ALLOWS MANUALLY SWITCHING TO AN ALARMED INTFC EITHER WORKING OR
PROTECTION. (THIS MAY INTERRUPT TRAFFIC) ( THIS MAY INTERRUPT TRAFFIC)

APS CONDITION SF
SET THE PRIORITY FOR SWITCHING UNDER SIGNAL FAIL (SF) CONDITION
PRIORITY HIGH: WHEN SF CONDITION IS DETECTED IN THE PROTECTION INTFC. KEEP ONLINE IN WORKING
INTFC
PRIORITY LOW: SF CONDITION HAS NO PRIORITY FOR WORKING OR PROTECTION INTFC

APS CONDITION SIGNAL DEGRADE

SELECT WHETHER TO USE SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING
INCLUDE SD: SELECT THIS TO CONSIDER STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING
EXCLUDE SD: SELECT THIS TO EXCLUDE STM-1 SIGNAL DEGRADE (SD) AS A CONDITION FOR APS SWITCHING

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 61


PROVISIONING APS CONDITION

LOCK IN USAGE

THIS FUNCTION PAUSE APS SWITCHING FOR A PERIOD OF TIME WHEN FREQUENT SWITCHING OCCURS IN THE
SYSTEM. FOLLOWING PARAMETERS ARE SET WHEN LOCK IN FUNCTION IS USED
USED: WHEN FREQUENT SWITCHING OCCURS BETWEEN WORK & PROT, PAUSE SWITCHOVER UNTIL
CONDITIONS SET IN LOCK IN COUNT, LOCK IN DETECT TIME & LOCK IN HOLD TIME ARE MET
NOT USED: ALLOW FREQUENT SWITCH OVER BETWEEN WORK & PROT INTFC.

LOCK IN USAGE SETTING

LOCK IN COUNT: SET THE NUMBER OF SWITCHOVERS COUNTED TO GO TO LOCK IN MODE WITHIN THE LOCK IN
DETECT TIME (1 TO 255)
LOCK IN DETECT TIME: SET THE TIME IN MINUTES. DURING WHICH THE NUMBER OF SWITCHOVER ARE
COUNTED FOR LOCK IN FUNCTION( 1 TO 60 MIN)
LOCK IN HOLD TIME: SET THE DURATION OF PAUSE (LOCK IN) DURING THE LOCK IN CONDITION (1 TO 48 HOUR)

CLICK THE EXECUTE BUTTON TO CHANGE


THE NAME

CLICK THE CLOSE BUTTON TO EXIT WHEN


FINISHED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 62


PROVISIONING
AUTOMATIC LASER SHUT DOWN

THE STM-1 OPTICAL INTFC IS PROVIDED WITH THE AUTOMATIC LASER


SHUTDOWN FUNCTION. ALS FUNCTION CAN BE ENABLE OR DISABLED.
WHEN ENABLED THE LASER OUTPUT OF THE INTFC STM-1 OUT IS
TURNED OFF WHEN THE STM-1 INPUT TO THE INTFC CARD IS
INTERRUPTED. WHEN THE ALS IS DISABLED LASER OUTPUT IS ALWAYS
ON EVEN WHEN THERE IS NO INPUT TO THE INTFC CARD.

DURING ALS OPERATION AT PREDEFINED INTERVALS 2 SEC LASER


PULSE IS OUT PUT FROM THE STM-1 INTFC.

SELECT ALS FUNCTION FROM THE PROVISIONING WINDOW

TO ENABLE ALS FUNCTION SELECT ENABLE RADIO BUTTON

IN THE ALS INTERVAL CLICK ON THE ARROW AND FROM THE DROP
DOWN LIST SELECT THE ALS INTERVAL 60 SEC, 180 SEC OR 300SEC.

CLICK THE EXECUTE BUTTON TO APPLY THE ALS SETTING.

CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 63


DXC CH SETTING
DXC FUNCTION PROVISIONING ITEM IS USED IN TERMINAL
MODE. DXC FUNCTION CAN BE ENABLED OR DISABLE IN
TERMINAL MODE. FOR REPEATER IT IS ENABLED

DXC CH SETTING PROVISIONING ITEM IS FOR SETTING E1


CROSS CONNECT BETWEEN DIR/A, DIR-B AND TRIBUTARY

SELECT DIR-A OR DIR-B FROM


THE DROP DOWN MENU
NO. OF CHANNELS FOR DIR-A OR DIR-B
DISPLAYED DEPENDS ON THE RADIO
TRANSMISSION CAPACITY SELECTED IN
SETUP

OVERALL VIEW

SHOWS THE CURRENT XC ASSIGNMENT


FOR DIR-A CHANNELS.
BLUE COLOR INDICATE DIR-A TO DIR-B
CHANNEL ASSIGNMENT

GREEN COLOR INDICATE DIR-A OR DIR-


SHOWS THE CURRENT XC ASSIGNMENT B ASSIGNED TO TRIBUTARY CHANNEL
FOR DIR-B CHANNELS.
PINK COLOR INDICATE TRIBUTARY CH
TO TRIBUTARY CH ASSIGNMENT
SHOWS THE CURRENT XC ASSIGNMENT
FOR TRIBUTARY CHANNELS.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 64


DXC SETTING MAP VIEW

THIS FUNCTION ALLOWS YOU TO VIEW


GRAPHICALLY THE CROSS CONNECT
ASSIGNMENTS CURRENT AND TO BE
SET

CLICK THE MAP (SETTING) BUTTON TO SEE THE ASSIGNMENTS BETWEEN DIR-A ,
DIR-B AND TRIBUTARY DURING DXC CONFIGURATION

CLICK THE MAP (CURRENT) BUTTON TO SEE THE CURRENT ASSIGNMENT


BETWEEN DIR-A , DIR-B AND TRIBUTARY

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 65


CH MAP VIEW
DIR-A
DIR-B

SHOWS THE NUMBER OF E1


ACCORDING TO THE AIR CONNECTION BETWEEN
CAPACITY RADIO DIRECTION A AND B IS
SHOWN IN BLUE COLOR

CHs IN WHITE ARE NOT USED


OR ASSIGNED

CONNECTION BETWEEN
RADIO DIRECTION AND
TRIBUTARY IS SHOWN IN
GREEN COLOR

CONNECTION FROM A TRIBUTARY


CH TO ANOTHER TRIBUTARY CH
IS SHOWN IN PURPLE COLOR

TRIBUTARY

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 66


DXC SETTING 1 ALL CHs OR MULTIPLE CHs
SET ALL CH
SET ALL BUTTON FUNCTION
ALLOWS ASSIGNING ALL CHs IN
DIR-A TO DIR-B OR ALL CHs IN
DIR-A TO TRIBUTARY CHs.

CLICK SET ALL BUTTON TO OPEN THE SET ALL CH CONTROL


WINDOW.
SELECT THE RADIO BUTTON DIR-A-> DIR-B, TO ASSIGN DIR-A
ALL CHANNELS TO DIR-B ONE TO ONE
SELECT THE RADIO BUTTON DIR-A-> TRIB, TO ASSIGN DIR-A
ALL CHANNELS TO TRIBUTARY CHs ONE TO ONE

CLICK OK TO IMPLEMENT THE CROSS CONNECTION

SET MULTIPLE CH
SET MULTIPLE BUTTON FUNCTION ALLOWS ASSIGNING SELECTED DIR-A CHs TO
DIR-B OR TRIBUTARY CHs, STARTING FROM THE CH SELECTED AS THE TOP CH IN
DIR-B OR TRIBUTARY

CLICK AND SELECT THE CHECK BOXES OF THE DIR-A


CHANNEL TO BE ASSIGNED.
CLICK THE DROP DOWN MENU AND SELECT THE DESTINATION
DIR-B OR TRIB
CLICK THE CH# DROP DOWN MENU AND SELECT THE
STARTING CH NUMBER FOR THE SELECTED DESTINATION
CLICK OK TO IMPLEMENT THE CROSS CONNECTION

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 67


DXC SETTING-2 FOR REPEATER

1 CLICK THE ARROW AND SELECT


CONNECTING DIRECTION DIR-A,
DIR-B

2 FOR THE CH TO BE ASSIGNED


SELECT THE DESTINATION

DESTINATION
CH TO BE
ASSIGNED
CH NUMBER

3 FOR THE CH TO BE ASSIGNED AND


FOR THE SELECTED DESTINATION,
CLICK AND SELECT THE CHANNEL
NUMBER FROM THE DROP DOWN
LIST

4 CLICK THE EXECUTE BUTTON TO


MAKE THE CROSS CONNECTION.
OVER ALL VIEW SHOWS THE
CONNECTION FOR DIR-A , DIR-B AND
TRIB.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 68


MAINTENANCE

COMMON TO PDH / SDH PDH ONLY

MAINTENANCE MODE MAIN CHANNEL LOOPBACK -1


TX SW MANUAL CONTROL (1+1) MAIN CHANNEL LOOP BACK -2
RX SW MANUAL CONTROL (1+1)
ATPC MANUAL CONTROL SDH ONLY
TX MUTE CONTROL APS MANUAL
CW CONTROL (LOCAL ONLY) MAIN LOOPBACK -1 INTFC-1
IF LOOPBACK (LOCAL ONLY) MAIN LOOP BACK -1 (INTFC-2)
DADE ADJUST (LOCAL ONLY) MAIN LOOP BACK 2
LAN DEVICE RESET ALS RESTART
LINEARIZER CONTROL XPIC CONTROL
RF SETTING (LOCAL ONLY)

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 69


MAINTENANCE MODE

MAINTENANCE WINDOW CAN BE OPENED IN TWO WAYS:

1 CLICK ON THE CONFIGURATION MENU IN THE NE


SPECIFIC MENU BAR AND SELECT MAINTENANCE

2 CLICK ON THE MAINT SYMBOL ON THE BLOCK


DIAGRAM DISPLAY ON THE PNMT WINDOW MAINTENANCE ON
STATUS IS
INDICATED BY THE
THE MAINTENANCE ITEMS SHOWN DEPENDS ON THE
YELLOW COLOR
EQUIPMENT CONFIGURATION AND SETUP

In Repeater NE, controls can be


applied to DIR-A & DIR-B

CLICK THE MAINTENANCE BUTTON ON THE MAINTENANCE


WINDOW TO OPEN THE MAINT MODE CONTROL WINDOW

SELECT MAINTENANCE ON RADIO BUTTON AND CLICK


EXECUTE TO GO TO MAINTENANCE MODE

SELECT MAINTENANCE OFF RADIO BUTTON AND CLICK


EXECUTE TO GO TO NORMAL OPERATING MODE

CLICK CLOSE TO EXIT THE MAINT CONTROL WINDOW

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 70


MAINTENANCE
MAINTENANCE CONTROL ITEMS AVAILABLE FOR LOCAL STATION AND REMOTE STATIONS ARE DIFFERENT.

ALL MAINTENANCE CONTROL ITEMS ARE SOME OF THE MAINTENANCE CONTROL ITEMS
AVAILABLE FOR THE LOCAL NE. ARE NOT ACTIVE WHEN THE PNMT ACCESS
THE NEs REMOTELY

LOCAL NE REMOTE NE

CW CONTROL AND IF
LOOPBACK CONTROLS
ARE NOT ACTIVE FOR
REMOTE NEs

THESE CONTROLS WHEN APPLIED TO REMOTE


NE CAN DISCONNECT THE RADIO LINK AND
THE PNMT LINK TO THE REMOTE NE, WITHOUT
WAY TO RESTORE THE LINK.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 71


MAINTENANCE MANUAL SW CONTROL
AVAILABILITY OF MANUAL SW CONTROL DEPENDS ON THE
EQUIPMENT REDUNDANCY CONFIGURATION. FOR (1+1) HOT
STANDBY CONFIGURATION BOTH TX AND RX SW MANUAL
CONTROLS ARE AVAILABLE BUT FOR (1+1) TWIN PATH ONLY
RX SW MANUAL CONTROL IS AVAILABLE.

RX SW MANUAL CONTROL TX SW MANUAL CONTROL

CLICK RX SW MANUAL CONTROL BUTTON ON THE MAINTENANCE CLICK TX SW MANUAL CONTROL BUTTON ON THE MAINTENANCE
DETAIL WINDOW. DETAIL WINDOW.

SELECT THE RADIO BUTTONS NO. 1 OR NO. 2 TO MANUALLY SELECT THE RADIO BUTTONS NO. 1 OR NO. 2 TO MANUALLY
SELECT THE RADIO CHANNEL. SELECT THE RADIO CHANNEL.

CLICK THE EXECUTE BUTTON TO APPLY THE SW CONTROL. CLICK THE EXECUTE BUTTON TO APPLY THE SW CONTROL.

TO NORMALIZE THE MAINTENANCE CONTROL SELECT AUTO TO NORMALIZE THE MAINTENANCE CONTROL SELECT AUTO
RADIO BUTTON AND CLICK EXECUTE BUTTON RADIO BUTTON AND CLICK EXECUTE BUTTON

CLICK THE CLOSE BUTTON TO EXIT RX SW MANUAL CONTROL CLICK THE CLOSE BUTTON TO EXIT TX SW MANUAL CONTROL
WINDOW. WINDOW.

TX SWITCHING MOMENTARILY INTERRUPT THE TRAFFIC

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 72


MAINTENANCE - TX MUTE
THIS MAINTENANCE CONTROL IS USED TO SWITCH TX MUTE CONTROL (LOCAL NE)
OFF THE RF OUTPUT OF THE ODU.
CLICK TX MUTE CONTROL BUTTON ON THE MAINTENANCE DETAIL
WINDOW . SELECT BUTTON CORRESPONDING TO THE ONLINE CH
NUMBER IN THE CASE OF HOT STANDBY. AS THE STANDBY
CHANNEL IS ALREADY MUTED.
IN THE CASE OF TWIN PATH SELECT EACH CH SEPARATELY
TO APPLY THE MUTE CONTROL.
CLICK ON THE MUTE ON RADIO BUTTON TO STOP THE ODU
OUT PUT POWER.
CLICK ON THE MUTE OFF RADIO BUTTON TO RESTORE THE
THE ODU OUT PUT POWER.
CLICK ON THE EXECUTE BUTTON TO APPLY THE
MAINTENANCE CONTROL
TX MUTE CONTROL (REMOTE NE) CLICK THE CLOSE BUTTON TO EXIT TX MUTE CONTROL WINDOW.
CLICK TX MUTE CONTROL BUTTON ON THE MAINTENANCE DETAIL
WINDOW . SELECT BUTTON CORRESPONDING TO THE ONLINE CH
NUMBER IN THE CASE OF HOT STANDBY. AS THE STANDBY CHANNEL
IS ALREADY MUTED. LOCAL NE REMOTE NE
IN THE CASE OF TWIN PATH SELECT EACH CH SEPARATELY TO APPLY
THE MUTE CONTROL.
CLICK ON THE MUTE ON RADIO BUTTON TO STOP THE ODU OUT PUT
POWER.
CLICK ON THE DROP DOWN ARROW IN TX MUTE OFF CONTROL TIME
AND SELECT THE CONTROL OFF TIME 90 SEC, 180 SEC OR 300 SEC.
CLICK ON THE EXECUTE BUTTON TO APPLY THE MAINTENANCE
CONTROL

CLICK THE CLOSE BUTTON TO EXIT TX MUTE CONTROL WINDOW.

NOTE
WHEN THE TX MUTE CONTROL IS APPLIED THE REMOTE NE, IT WILL
CUT OFF ODU OUT PUT POWER FOR THE DURATION OF TX MUTE
OFF CONTROL TIME, RESTORE IT BACK. DURING THE MUTE ON TIME THIS CONTROL MAY INTERRUPT THE TRAFFIC
THE PNMT LINK TO THE REMOTE NE WILL BE DISCONNECTED.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 73


MAINTENANCE CW CONTROL
THIS CONTROL INTERRUPT THE TRAFFIC

THIS CONTROL IS USED TO TRANSMIT AN UN


MODULATED CARRIER FROM THE ODU FOR
TEST PURPOSE. THIS CONTROL IS
AVAILABLE ONLY IN LOCAL NE.

CW CONTROL (LOCAL NE)

CLICK CW CONTROL BUTTON ON THE MAINTENANCE DETAIL


WINDOW CORRESPONDING TO THE CH YOU WISH TO TRANSMIT
AN UN MODULATED CARRIER.

CLICK ON THE CW ON RADIO BUTTON TO SELECT


TRANSMISSION OF UN MODULATED CARRIER FROM THE
SELECTED ODU

CLICK ON THE EXECUTE BUTTON TO APPLY THE MAINTENANCE


CONTROL. THIS MAY INTERRUPT THE RADIO LINK.

AFTER THE MAINTENANCE TESTING, SELECT THE CW CONTROL


OFF RADIO BUTTON AND EXECUTE BUTTON TO NORMALIZE THE
MAINTENANCE CONTROL

CLICK THE CLOSE BUTTON TO EXIT CW CONTROL WINDOW.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 74


MAINTENANCE IF LOOP BACK
THIS CONTROL INTERRUPT THE TRAFFIC.
DURING THE IF LOOP BACK THE SELECTED
CHANNEL ODU OUTPUT IS MUTED

THIS CONTROL IS AVAILABLE FROM THE LOCAL NE


ONLY. IT PROVIDES A LOOPBACK AT THE MODEM
OUTPUT INTERNALLY TOWARDS THE MUX DIRECTION
FOR TEST PURPOSE.

IF LOOP BACK (LOCAL NE)


INTFC MODULATOR
CLICK IF LOOPBACK BUTTON ON THE MAINTENANCE DETAIL
DEMODULATOR WINDOW CORRESPONDING TO THE CH YOU WISH TO ESTABLISH
TEST AN IF LOOPBACK.
EQUIP
MODULATOR
LOOPBACK CLICK ON THE IF LOOPBACK ON RADIO BUTTON FOR IF
DEMODULATOR
HITLESS LOOPBACK FROM THE SELECTED CH.
SW

CLICK ON THE EXECUTE BUTTON TO APPLY THE IF LOOP BACK


NOTE
MAINTENANCE CONTROL. THIS MAY INTERRUPT THE RADIO LINK.
WHEN ESTABLISHING THE IF LOOPBACK IN (1+1) CONFIGURATION.
MAKE SURE THAT THE CH TO BE TESTED IS THE CHANNEL THAT IS AFTER THE MAINTENANCE TESTING, SELECT THE IF LOOPBACK
SELECTED FOR RECEIVE. OTHER WISE THE LOOPBACK SIGNAL IS OFF RADIO BUTTON AND EXECUTE BUTTON TO NORMALIZE THE
NOT PASSED AT THE HITLESS SWITCH AS SHOWN IN THE ABOVE MAINTENANCE CONTROL
FIGURE. CH SELECTED FOR RECEIVE IS CH 1, CH SELECTED FOR
LOOPBACK IS CH 2. LOOPBACK SIGNAL IS NOT THROUGH TO TEST CLICK THE CLOSE BUTTON TO EXIT IF LOOPBACK CONTROL
EQUIPMENT. WINDOW.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 75


MAINTENANCE NEAR END LOOP BACK
THIS CONTROL MAY INTERRUPT THE SELECTED E1S TRAFFIC

TWO TYPES OF LOOP BACKS ARE AVAILABLE FOR THE MAIN


INTERFACE CARD. IN THE CASE OF PDH LOOPBACK IS AVAILABLE ALL SELECT
FOR EACH INDIVIDUAL E1 CHANNEL.
MAIN CH LOOP BACK -1 IS THE NEAR END LOOP BACK
MAIN CH LOOPBACK - 2 IS THE FAR END LOOPBACK

MAIN CH LOOP BACK - 1

CLICK ANY MAIN CH LOOPBACK-1 BUTTONS ON THE MAINTENANCE


DETAIL WINDOW..
ON THE MAIN CH LOOPBACK -1 CONTROL WINDOW, THERE ARE ALL CLEAR
SEVERAL WAYS TO SELECT THE LOOPBACK CHANNELS.

CLICK ON EACH E1 CH NUMBER YOU WANT TO HAVE THE


NEAR END LOOP BACK ESTABLISHED NORMALIZE MAIN CH LOOP BACK - 1
OR CLICK ON ALL SELECT BUTTON TO PROVIDE LOOPBACK ON CLICK ON THE INDIVIDUAL E1 CH TO RELEASE THE LOOPBACK
ALL E1 CHANNELS. SELECTED CHANNELS ARE SHOWN IN CONTROL
YELLOW COLOR
OR CLICK ON THE ALL CLEAR BUTTON
CLICK THE EXECUTE BUTTON TO APPLY THE LOOPBACK ON THE
SELECTED E1 CHANNELS CLICK THE EXECUTE BUTTON TO APPLY THE LOOPBACK ON THE
SELECTED E1 CHANNELS
CLICK THE CLOSE BUTTON TO EXIT MAIN CH LOOPBACK CONTROL
WINDOW. CLICK THE CLOSE BUTTON TO EXIT MAIN CH LOOPBACK CONTROL
WINDOW.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 76


MAINTENANCE FAR END LOOPBACK
THIS CONTROL MAY INTERRUPT THE SELECTED E1S TRAFFIC

MAIN CH LOOP BACK - 2

CLICK ANY MAIN CH LOOPBACK-2 BUTTONS ON THE


MAINTENANCE DETAIL WINDOW..
ON THE MAIN CH LOOPBACK -2 CONTROL WINDOW, FAR
END LOOPBACK CAN BE GIVEN TO DIR-A AND/OR DIR-B.

CLICK ON EACH E1 CH NUMBER IN DIR-A/DIR-B YOU WANT


TO HAVE THE FAR END END LOOP BACK ESTABLISHED
OR
CLICK ON ALL SELECT BUTTON TO PROVIDE LOOPBACK ON
ALL E1 CHANNELS. SELECTED CHANNELS ARE SHOWN IN
YELLOW COLOR
CLICK THE EXECUTE BUTTON TO APPLY THE LOOPBACK ON
THE SELECTED E1 CHANNELS

NORMALIZE MAIN CH LOOP BACK - 2


ABOVE WINDOW APPEARS WHEN XC
CLICK ON THE INDIVIDUAL E1 CH TO RELEASE THE LOOPBACK CONTROL SETTING IS ENABLED
OR CLICK ON THE ALL CLEAR BUTTON
CLICK THE EXECUTE BUTTON TO APPLY THE LOOPBACK ON THE SELECTED E1
CHANNELS CLICK THE CLOSE BUTTON TO EXIT THE
MAIN CH LOOPBACK 2 CONTROL WINDOW.
CLICK THE CLOSE BUTTON TO EXIT THE MAIN CH LOOPBACK CONTROL WINDOW.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 77


MAINTENANCE DADE ADJUST

THIS IS AN OFFLINE MAINTENANCE ITEM

THIS CONTROL INTERRUPT THE TRAFFIC

DADE ADJUST
THIS CONTROL IS AVAILABLE FOR (1+1) SPACE
DIVERSITY CONFIGURATION AND SHOULD BE CLICK DADE ADJUST BUTTON ON THE MAINTENANCE DETAIL WINDOW
ADJUSTED DURING INSTALLATION. THIS
CONTROL ADJUST ANY DELAY BETWEEN CLICK ON THE DADE RADIO BUTTON TO MAKE DELAY ADJUSTMENT IN
CHANNEL 1 AND 2 AT THE IN PUT OF THE THE STANDBY PATH
RECEIVE HITLESS SWITCH IN THE INTERFACE
CLICK ON THE EXECUTE BUTTON TO APPLY THE DADE CONTROL
CARD SO THAT THE TWO PATHS ARE IN
PHASE. IF THEY ARE NOT IN PHASE, THE OUT
OF PHASE ALARM IS RAISED. AFTER ADJUSTING THE DADE , TO REDUCE THE TOTAL DELAY ON THE
RECEIVE PATH (IF REQUIRED), CLICK ON THE OFFSET DADE RADIO
BUTTON AND CLICK THE EXECUTE BUTTON
DADE ADJUST MENT IS AVAILABLE IN TERMAINAL
MODE ONLY. REPEATER MODE THIS ITEM DOES NOT (OFFSET DADE ADJUSTMENT INTERRUPT TRAFFIC)
APPEAR ON THE MAINTENANCE MENU.
CLICK THE CLOSE BUTTON TO EXIT DADE ADJUST CONTROL WINDOW.

SELECT DADE OFF WHEN DADE FUNCTION IS NOT USED

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 78


MAINTENANCE OFFLINE

THESE ARE AN OFFLINE MAINTENANCE ITEM

WHEN ANTENNA ALIGNMENT IS CARRIED OUT THE RECEIVE


NEO ODU SUB-BAND CAN BE CHANGED BY CHANGING THE AGC LEVEL CAN BE MONITORED BY CONNECTING A VOLT
TX/RX RF BAND PASS FILTER. AFTER CHANGING THE BPF, METER TO THE ODU RX LEV MONITOR POINT. TO EXTEND THE
NEW SUB-BAND LETTER SHOULD BE SET USING THIS OFFLINE DYNAMIC RANGE OF THE MONITORED AGC LEVEL SET THIS
MAINTENANCE CONTROL. DO NOT ADJUST WHILE ONLINE, IT CONTROL ON OTHERWISE THE INDICATED AGC LEVEL IS NOT
MAY INTERRUPT THE RADIO LINK GUARANTEED

ANTENNA ALIGNMENT MODE


RF SETTING
CLICK THE ANTENNA ALIGNMENT MODE BUTTON ON THE
CLICK THE RF SETTING BUTTON ON THE MAINTENANCE DETAIL
MAINTENANCE DETAIL WINDOW
WINDOW
CLICK ON THE ANTENNA ALIGNMENT MODE ON RADIO BUTTON
CLICK ON THE SUB BAND DROP DOWN ARROW AND SELECT THE
NEW SUB-BAND LETTER CLICK ON THE EXECUTE BUTTON TO APPLY THE ANTENNA
ALIGNMENT MODE
CLICK ON THE EXECUTE BUTTON TO APPLY THE SUB-BAND
CLICK THE CLOSE BUTTON TO EXIT ANTENNA ALIGNMENT MODE
CLICK THE CLOSE BUTTON TO EXIT RF SETTING CONTROL WINDOW.
WINDOW.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 79


MAINTENANCE
APS MANUAL CONTROL

THIS MAINTENANCE FUNCTION SELECT AUTO OR MANUAL SWITCHING OF STM-1


INTFC UNDER APS.
SELECT AUTO RADIO BUTTON TO SWITCH AUTOMATICALLY DUE TO ALARM / FAILURE
OF STM-1 ONLINE INTFC.
SELECT WORKING OR PROTECTION RADIO BUTTON TO SELECT MANUALLY STM-1
INTFC WORKING OR PROTECTION
MANUAL SWITCHING OPERATE UNDER THE CONDITION SET IN PROVISIONING APS
MAINTENANCE MODE.
CLICK EXECUTE BUTTON TO APPLY THE MAINTENANCE CONTROL.
CLICK CLOSE BUTTON TO EXIT THE CONTROL WINDOW.

XPIC CONTROL

THIS MAINTENANCE FUNCTION MANUALLY RESET THE


XPIC FUNCTION ( DISABLE XPIC FUNCTION).
CLICK XPIC CONTROL BUTTON IN MAINTENANCE
WINDOW.
SELECT AUTO RADIO BUTTON TO ENABLE XPIC
FUNCTION AND AUTOMATICALLY RESETTING OF XPIC
DUE TO ALARM. (NORMAL OPERATIONAL SETTING)

SELECT FORCED RESET RADIO BUTTON TO DISABLE


THE XPIC FUNCTION.
CLICK EXECUTE BUTTON TO APPLY THE MAINTENANCE
CONTROL
CLICK CLOSE BUTTON TO EXIT THE CONTROL WINDOW

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 80


NE STORED LOG
ALL EVENTS OCCURRING IN THE NE IS LOGGED AND STORED IN THE IDU. THIS LOG
CAN BE VIEWED FROM THE PNMT. NE STORED LOG WINDOW SHOW THE MOST
RECENT 300 EVENTS STORED IN THE NE STORED LOG.

CLICK THE NE STORED LOG ICON ON THE NE


SPECIFIC MENU BAR.
THE EVENT LOG IS THEN UPLOADED FROM
THE SELECTED NE. ONLY THE MOST RECENT
300 EVENTS WILL BE DISPLAYED

SORTING IS POSSIBLE FOR EVERY COLUMN,


CLICK ON THE COLUMN TITLE TO SORT

WHILE UPLOADING OR WHEN


REFRESHING THE DATA STATUS BAR TOTAL EVENTS STORED AND THE
SHOWS ACQUIRING DATA FILE SIZE IS INDICATED HERE
PROGRESS OF UPLOADING OR
REFRESHING IS SHOWN BY THIS
PROGRESS BAR

RELOAD

EVENT LOG SHOWN IS NOT IN REAL TIME TO SEE THE


CURRENT EVENTS SELECT RELOAD

SAVE AS

TO SAVE THE NE STORED EVENT LOG FILE SELECT TEXT COLOR CODE
SAVE AS FROM THE FILE MENU OR TOOL BAR
ALARM EVENT IN RED
PRINT NORMAL OR RECOVERED EVENT IN GREEN
CONTROL EVENT IN BLUE
TO PRINT THE EVENT LOG SELECT PRINT FROM THE
CONTROL RESPONSE OR STATUS EVENT IN WHITE
FILE MENU OR THE TOOL BAR

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 81


PERFORMANCE MONITOR - METERING
CLICK ON THE PERFORMANCE MONITOR MENU IN THE NE SPECIFIC MENU
BAR AND SELECT METERING

REPEATER

METERING INFORMATION IS REFRESHED


EVERY 10SEC. THE TIME TO NEXT
REFRESH IS INDICATED BY THE
PROGRESS BAR

1+1 HOT STANDBY 1+1 TWIN PATH

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 82


PERFORMANCE MONITOR
CLICK THE PERFORMANCE MONITOR MENU IN THE NE SPECIFIC MENU BAR AND
SELECT LINK PERFORMANCE MONITOR.

LINK PERFORMANCE MONITOR

LINK PERFORMANCE MONITOR WINDOW SHOWS THE PERFORMANCE MONITOR ITEM


VALUES AT THE TIME THE WINDOW IS OPENED, WITHIN THE CURRENT 15 MIN PERIOD.
THE VALUES ARE NOT SHOWN IN REAL TIME AND NEED TO REFRESH TO SEE THE
CURRENT VALUES.

LINK PERFORMANCE MONITOR (DAILY TOTAL)

CLICK THE DETAIL BUTTON TO SEE THE DAILY


TOTAL FOR EACH DAY FOR EACH MONITORED
ITEM.

LINK PERFORMANCE MONITOR (15 MIN TOTAL)

CLICK THE DATE BUTTON TO SEE THE 15 MIN DATA FOR


THAT DAY

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 83


PERFORMANCE MONITOR
ALARM OCCUR AND
RECOVER THRESHOLD
SETTING FOR THE PM ITEMS
FOR 15 MIN AND 1 DAY

CLICK ON THE THRESHOLD BUTTON ON THE LINK


PERFORMANCE MONITOR WINDOW TO OPEN THE LINK
PERFORMANCE MONITOR THRESHOLD WINDOW.

PERFORMANCE ALARM OCCUR THRESHOLD AND


FOR PDH E1 ONLY ONE TAB
RECOVER THRESHOLD LEVEL CAN BE SET FROM THIS
WINDOW. CHANGE THE THRESHOLD SETTING AND
CLICK THE EXECUTE BUTTON TO APPLY THE SETTING

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 84


CTRL

COMMON TO PDH / SDH

DATE TIME SETTING


CPU RESET
DOWNLOAD CONFIGURATION FILE
DOWNLOAD PROGRAM FILE
DOWNLOAD EQUIPMENT CONFIG FILE
DOWNLOAD SOFTWARE KEY FILE

UPLOAD CONFIG FILE


UPLOAD EQUIPMENT CONFIG FILE
UPLOAD SOFTWARE KEY FILE
EQUIPMENT NETWORK SETTING

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 85


CTRL DETAIL
CLICK THE CTRL SYMBOL IN THE
BLOCK DIAGRAM OR THE CTRL
TAB IN THE DETAIL WINDOW TO
SEE THE CTRL CONTROLS AND
STATUS DETAIL

STATUS INFORMATION FOR THE CTRL DEPENDS ON THE


CONFIGURATION

CTRL ALARM STATUS


MMC MOUNT STATUS
APS SW FAIL STATUS (APS FUNCTION IN SDH CONFIGURATION)
APS ONLINE STATUS (APS FUNCTION IN SDH CONFIGURATION)

APS LOCK-IN STATUS (APS FUNCTION IN SDH CONFIGURATION)

FOLLOWING CONTROLS ARE AVAILABLE FOR THE CTRL MODULE

DATE / TIME SETTING FOR THE NE


DOWNLOAD CONFIGURATION FILES
DOWNLOAD PROGRAM FILES
DOWNLOAD EQUIPMENT CONFIGURATION FILE
DOWNLOAD SOFTWARE KEY FILE

UPLOAD CONFIGURATION FILE FILES


UPLOAD EQUIPMENT CONFIGURATION FILE
UPLOAD SOFTWARE KEY FILE

EQUIPMENT NETWORK SETTING

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 86


DATE TIME SETTING
DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENTS CTRL CARD
CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM
DETAIL WINDOW FOR CTRL
[PMC WINDOW]

GET DATE/ TIME

CLICK DATE/TIME BUTTON IN THE CTRL DETAIL


WINDOW TO OPEN THE DATE/TIME SETTING
CONTROL WINDOW

TO DISPLAY THE CURRENT DATE/TIME STORED


IN THE CTRL CARD, SELECT GET DATE/TIME
RADIO BUTTON AND CLICK EXECUTE.

CURRENT DATE/TIME WILL BE DISPLAYED IN THE


DATE/ TIME FIELDS

SET DATE/ TIME

TO SET DATE/TIME CLICK ON THE SET DATE /TIME


RADIO BUTTON

ENTER THE DATE AND TIME IN THE DATE/TIME


ENTRY FIELDS
OR CLICK THE DISPLAY PC TIME CHECK BOX TO
SET THE DATE TIME OF THE PNMTj PC TIME TO
THE NE
CHANGE THE DATE /TIME SETTING AS
REQUIRED, CLICK THE EXECUTE BUTTON.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 87


CTRL CPU RESET
CTRL CPU AND THE ODU CPU CAN BE RESET UNDER MAINTENANCE MODE

[PMC WINDOW]
DETAIL WINDOW FOR CTRL
CPU RESET - CTRL

RESETTING THE CTRL MODULE WILL NOT AFFECT


TRAFFIC. PNMT CONNECTION TO THE SELECTED
NE WILL BE LOST FOR A FEW MINUTES. REQUIRE
RE-CONNECTION
SELECT MAINTENANCE MODE

CLICK THE CPU RESET BUTTON ON THE DETAIL


WINDOW FOR CTRL.
CLICK ON THE CTRL RADIO BUTTON
SELECT THE CHECK BOX WITH ROM (PROGRAM)
SWITCHING IF IT IS REQUIRED

CLICK THE EXECUTE BUTTON TO RESET THE CTRL


CPU.

CPU RESET - ODU

RESETTING THE ODU CPU WILL AFFECT TRAFFIC.

SELECT MAINTENANCE MODE

CLICK THE CPU RESET BUTTON ON THE DETAIL


WINDOW FOR CTRL.

CLICK ON THE ODU RADIO BUTTON


CLICK THE EXECUTE BUTTON TO RESET THE ODU
CPU.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 88


CTRL - DOWNLOAD CONFIGURATION FILES
THIS FUNCTION IS USED TO DOWNLOAD CONFIGURATION FILES CREATED BY THE NETWORK
[PMC WINDOW] CONFIG TOOL TO THE CTRL IN THE SELECTED NETWORK ELEMENT. THERE ARE TWO FILES
DETAIL WINDOW FOR CTRL
CREATED FOR EACH NE, MIB.CFG CONTAINS THE IP ADDRESS OF THE NE AS WELL AS THE IP
ADDRESS OF THE OPPOSITE STATION. THE NETWORK.CFG FILE CONTAINS THE INFORMATION
ABOUT THE PASOLINK NETWORK WHERE NE IS LOCATED.

1 DOWNLOAD - CONFIGURATION FILES

CLICK THE CONFIGURATION FILE BUTTON IN THE


DETAIL WINDOW FOR CTRL, TO OPEN THE
DOWNLOAD CONFIGURATION FILE WINDOW.

DOWNLOAD
SELECT EACH CONFIG FILE ONE BY ONE FROM
THE TYPE WINDOW
BROWSE AND SELECT THE PATH/LOCATION TO
THE FILE SELECTED IN THE TYPE WINDOW.

CLICK EXECUTE BUTTON TO DOWNLOAD THE


SELECTED CONFIG FILE..
2 UPDATE
REPEAT THE DOWNLOAD PROCEDURE FOR THE
AFTER THE SUCCESSFUL DOWNLOAD OF THE OTHER CONFIG FILE..
CONFIGURATION FILES. CLICK THE UPDATE
BUTTON. UPDATE CONFIGURATION FILE WINDOW DOWNLOAD PROGRESS IS
OPENS. INDICATED BY THE PROGRESS BAR.

THE APPROPRIATE CHECK BOX FOR THE TYPE OF


CONFIGURATION FILE(S) THAT NEEDS TO BE WARNING
UPDATED WILL BE SELECTED. CONFIRM THAT THE
DOWNLOADED FILES ARE SELECTED. MAKE SURE THAT THE CORRECT CONFIGURATION
FILE IS DOWNLOADED TO THE CTRL IN THE
CLICK EXECUTE BUTTON TO START THE UPDATE CORRECT NE. INCORRECT CONFIGURATION FILE
OPERATION.. WILL LEAD TO CTRL OR NETWORK FAILURE
WHEN UPDATING, CTRL COMMUNICATION WILL BE
MAKE SURE THAT YOU HAVE SUCCESSFULLY
LOST WHEN CTRL INITIALIZES TO THE NEW
DOWNLOADED THE CONFIGURATION FILE BEFORE
SYSTEM CONFIGURATION. DURING THIS TIME
DOING UPDATE. OTHERWISE THE CTRL WILL
PNMT CONNECTION TO THE PASOLINK WILL BE
SWITCH TO AN EMPTY ROM THAT MAY CAUSE CTRL
LOST BUT WILL AUTOMATICALLY BE
FAILURE.
RECONNECTED AFTER THE CTRL RESETS

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO


CLICK CLOSE BUTTON WHEN DONE
89
DOWNLOAD PROGRAM FILE
THIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE CTRL, ODU
OR FPGA. . PROGRAM DOWNLOAD

CLICK THE DL PROGRAM FILE BUTTON IN THE


DETAIL WINDOW FOR CTRL DETAIL WINDOW FOR CTRL, TO OPEN THE
DOWNLOAD PROGRAM FILE WINDOW.

IN THE MODULE SELECT:


SELECT THE RADIO BUTTON FOR THE MODULE THE
APPLICATION PROGRAM IS TO BE DOWNLOADED.
CTRL IF CTRL IS SELECTED, CLICK THE CHECK
BOX WITH SELF RESET, IF CTRL MODULE RESET IS
REQUIRED AFTER THE PROGRAM DOWNLOAD.
ODU IF ODU IS SELECTED, CLICK THE RADIO
BUTTON 1 TO DOWNLOAD TO ODU 1 AND RADIO
BUTTON 2 TO DOWNLOAD TO ODU 2.
FPGA IF FPGA IS SELECTED, CLICK THE RADIO
BUTTON FOR THE MODULE THE FPGA PROGRAM IS
TO BE DOWNLOADED..
PACKAGE PROGRAM IF APPLICATION PROGRAM
IS TO BE DOWNLOADED TO SEVERAL DIFFERENT
MODULES. THE FILE MAY COME IN AS A A PACKAGE
RESETTING THE CTRL WILL NOT AFFECT THE PROGRAM FILE
TRAFFIC. THE CONNECTION TO THE SELECTED
IN THE FILE SECTION:
PASOLINK WILL BE LOST FOR FEW MINUTES
AND WILL BE RECONNECTED AUTOMATICALLY. ENTER THE PATH TO THE PROGRAM FILE TO BE
DOWNLOADED OR CLICK BROWSE TO LOCATE
THE PROGRAM FILE.
CLICK THE EXECUTE BUTTON TO START DOWNLOAD
OPERATION
DOWNLOAD PROGRESS IS INDICATED BY THE
WARNING PROGRESS BAR. WHEN THE DOWNLOADING IS
COMPLETED, SELECT CPU RESET BUTTON ( SEE
MAKE SURE THAT THE CORRECT PROGRAM FILE CPU RESET OPERATION)
IS DOWNLOADED TO THE MODULE SELECTED. CLICK CLOSE BUTTON TO EXIT THE DOWNLOAD
INCORRECT PROGRAM FILE MAY LEAD TO PROGRAM FILE WINDOW
MODULE FAILURE.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 90


EQUIPMENT CONFIGURATION FILE
DETAIL WINDOW FOR CTRL EQUIPMENT CONFIGURATION FILE CONTAIN INFORMATION ABOUT THE NE CONFIGURATION LIKE
FREQUENCY, MAIN INTERFACE AND PROVISIONING DATA ETC.. THIS FILE CAN BE UPLOADED TO THE PNMT
PC AS A BACK UP FILE.
WHEN THE PASOLINK IDU FOR A SITE IS REPLACED FOR SOME REASON THE EQUIPMENT CONFIGURATION
FILE CAN BE DOWNLOADED TO CONFIGURE THE REPLACED IDU.

2
DOWNLOAD EQUIPMENT CONFIG FILE

CLICK THE DL EQUIPMENT CONFIGURATION FILE


BUTTON IN THE DETAIL WINDOW FOR CTRL, TO OPEN
THE DOWNLOAD EQUIPMENT CONFIGURATION FILE
WINDOW.
USE BROWSE TO SELECT THE DIRECTORY WHERE THE
FILE IS LOCATED AND SELECT THE CORRECT
1 EQUIPMENT CONFIG FILE. CHECK THE HEADER
UPLOAD EQUIPMENT CONFIG FILE
INFORMATION TO CONFIRM TO CONFIRM THE
EQUIPMENT NAME ETC. ARE CORRECT.
CLICK THE UL EQUIPMENT CONFIGURATION FILE BUTTON IN THE DETAIL
WINDOW FOR CTRL, TO OPEN THE UPLOAD EQUIPMENT CONFIGURATION CLICK EXECUTE BUTTON TO START THE DOWNLOAD
FILE WINDOW. OPERATION. A MESSAGE WINDOW APPEARS TO SHOW
THE STATUS OF THE DOWNLOAD OPERATION, AND WILL
USE BROWSE TO SELECT THE DIRECTORY WHERE THE FILE IS TO BE CLOSE AUTOMATICALLY ONCE THE OPERATION IS
SAVED. ENTER THE DESIRED NAME FOR THE UPLOADED FILE. COMPLETED..
CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE CLICK THE UPDATE BUTTON TO OPEN THE UPDATE
WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION, EQUIPMENT CONFIG FILE WINDOW. SELECT THE CHECK
AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED.. BOX AND CLICK EXECUTE BUTTON START THE UPDATE
AFTER THE UPLOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE OPERATION
THE WINDOW. CLICK THE CLOSE BUTTON TO EXIT THE WINDOW.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 91


UPLOAD CONFIGURATION FILE
DETAIL WINDOW FOR CTRL NETWORK CONFIG FILE IS NORMALLY CREATED FROM THE NETCONFIGTOOL FOR NEO AND
DOWNLOADED TO THE NE. UPLOADING THIS FILE TO KEEP A BACKUP IN CASE THE CTRL
MODULE IS REPLACED.

UPLOAD CONFIGURATION FILE

CLICK THE UD CONFIGURATION FILE BUTTON IN THE DETAIL WINDOW FOR


CTRL, TO OPEN THE UPLOAD CONFIGURATION FILE WINDOW.
SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE
WINDOW., MIB CONFIG OR NETWORK CONFIG.
ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN
THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF
NECESSARY.
CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE
WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION,
AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED..

AFTER THE UPLOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE


THE WINDOW.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 92


NETWORK PARAMETER SETTING EXAMPLE-1
CLICK THE CONTROL ICON TO OPEN THE EQUIPMENT
NETWORK SETTING WINDOW.
WHEN THE WINDOW START UP IT WILL LOAD THE CURRENT
NETWORK SETTING IN THE NE AND DISPLAY THE SETTING.
DEPENDING ON THE NES CTRL TYPE, THE ITEMS
DISPLAYED VARY.

CLICK THE CONTROL ICON TO OPEN THE EQUIPMENT


NETWORK SETTING WINDOW.
WHEN THE WINDOW START UP IT WILL LOAD THE CURRENT
NETWORK SETTING IN THE NE AND DISPLAY THE SETTING.
DEPENDING ON THE NES CTRL TYPE, THE ITEMS
DISPLAYED VARY.

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 93


NETWORK PARAMETER SETTING
CRTL Type (General) Category Input Item
FOR DIFFERENT CTRL TYPES THE CATEGORY ITEMS AVAILABLE IS DIFFERENT CTRL Type Branch NE Type
Equipment Type
General CTRL Type
ROOT NE Not Selectable Branch NE Type
DIR-A / DIR-B/EM2 IP Address
Subnet Mask
PNMS (EM1) IP Address
NE CONNECTED TO THE
PNMS IS SET AS ROOT NE Subnet Mask
ROUTING Default Gateway
Static Routing Table
Equipment Type
General CTRL Type
ROOT NE (BRIDGE) Branch NE Type
DIR-A/DIR-B/EM2/EM1 IP Address
Subnet Mask
Not Selectable Routing Default Gateway
Static Routing Table
Equipment Type
General CTRL Type
Branch NE Type
BRANCH NE 2 BRANCH DIR-A IP Address
Subnet Mask
DIR-B/EM1/EM2 IP Address
Subnet Mask
Routing Default Gateway
NE STARTING A SUBNET IS Static Routing Table
SET TO BRANCH NE Equipment Type
General CTRL Type
Branch NE Type
3 BRANCH DIR-A IP Address
Subnet Mask
DIR-B IP Address
Subnet Mask
EM1/EM2 IP Address
Subnet Mask
Routing Default Gateway
Static Routing Table
Equipment Type
General CTRL Type
Branch NE Type
DIR-A IP Address
Subnet Mask
DIR-B IP Address
Subnet Mask
EM-2 IP Address
Subnet Mask
EM-1 IP Address
Subnet Mask
Routing Default Gateway
Static Routing Table

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 94


CTRL TYPE ROOT NE

192.168.0.1

192.168.0.10

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 95


CTRL TYPE BRANCH NE

172.18.0.65

172.18.0.1

172.18.0.3

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 96


CTRL TYPE NORMAL NE

172.18.0.66

172.18.0.65

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 97


NETWORK PARAMETER SETTING EXAMPLE-1
ONE SUBNET CONFIGURATION EXAMPLE

172.18.0.1

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 98


NETWORK PARAMETER SETTING EXAMPLE-2

EXAMPLE OF SEVERAL SUBNETS IN THE NETWORK


WITH BRANCH NE TYPE EQUAL TO 2 BRANCHES

172.18.0.1

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 99


NETWORK PARAMETER SETTING EXAMPLE-3

EXAMPLE OF SEVERAL SUBNETS IN THE NETWORK


WITH BRANCH NE TYPE EQUAL TO 3 BRANCHES

172.18.0.1

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 100


NETWORK PARAMETER SETTING EXAMPLE-4

EXAMPLE OF CTRL TYPE ROOT BRIDGE

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 101


Thank you

TOPC-E4015E-02-07416 PNMTj for PASOLINK NEO 102