You are on page 1of 6

PROJECT : APARTMENT BUILDING (B+G+3)

AT OLD AIRPORT ROAD, DOHA, QATAR.


MATERIAL COMPLIANCE SHEET
Material Description: Framing System for False Ceiling (Metal Frame and Gypsum Board)

DRYWALL SUSPENDED CEILING Appendix to submittal ref. PROJECT SPECIFICATION Revision: 1 Date: 27/8/2017
Specifications Material references
Sr No
Clause &
CICO Comments
Section Title / Designation Criteria Document Page Title / Designation Compliance Remarks
Sub Clause

A. This Part includes conventional non-load


bearing steel framing systems for interior
both the system for
gypsum board assemblies.
PERFORMANCE EXMET BLUE 1.DRYWALL PARTITION gypsum accessories are
1 K45 1.4
REQUIREMENTS
suspension systems for interior gypsum
CATALOGUE
23-28
2. SUSPENDED CELINGS
COMPLIED used for Non load bearing
ceilings. soffits and grid systems.
system

B. Engage a qualified Professional Engineer


with license to practice in Doha Qatar. and I Exmet provides structural
or approved by Qatar calculation for celing and
PERFORMANCE Statutory Authotity having jurisdiction, to wall system based on
2 K45 1.4
REQUIREMENTS
COMPLIED project requirementrs as
design cold - formed metal framing.
per architectural drawings (
if any)

C. Cold - formed Steel Framing, General :


The design shall be in accordance with AISI
requirements, Al SI 100 and
AISl 200 series.
PERFORMANCE (a) Headers for door or windows & hatches.
3 K45 1.4
REQUIREMENTS (b) Wall Studs for internal partitions.
COMPLIED
(c) Lateral Braces for internal walls and
partitions.
(d) Furrying channel for suspended ceilings.

B. Shop Drawings showing interior elevation


of walls, ceiling plan, sections, details
including fabrication and
installation method :
(a) Studs, runners. braces and accessories.
(b) Hanger inserts.
4 K45 1.5 SUBMITTALS
(c) Channels cold-formed steel.
NOTED
{d) Furring channel .
(e) Typical ceiling suspension system.
{f) Typical metal wd and furring
construction sys tem includin g details
around openings and corner details
(a) Provide structural calculation duly signed
and sealed by a licensed Suuctural Engineer
C. Structural qualified to practice
5 K45 1.5
Calculations: the profession in Doha, Qatar and NOTED
registered. accredited in .tvfMUP
Engineering Committee.
(b) Calculation shall include.
(i) De ign Criteria
(ii) Engineering Analysis depicting stress and
deflection requirements for each framing
C. Structural
6 K45 1.5
Calculations:
application. NOTED
(iii) Selection of framing components.
accessories and welded connection
requirements.
(iv) Attachments to structure an d adjacent
framing
D. components
Test Reports: 'Fornon-structural steel ASTM C 645 & ASTM 754
framing complying with ASTM C645-13 and requires test results for
ASTM C754-l l, provide system with composite
C. Structural independent laboratory test reports COMPLIED WITH assembly. Exmet provides
7 K45 1.5 showing maximum spacing and deflection. system which are
Calculations: COMMENTS
considering non composite
sheathing action and
design provision of AISI
S100.
Proposal drawing for the
E. Coordination Drawings showing the
system will be provided.
following : COMPLIED WITH
C. Structural Shop drawing will be
8 K45 1.5 (a) Support systems for wall and ceiling
Calculations: COMMENTS provided if specific length &
assembly.
detail requirements are
(b) Method of attachment to building
implemented
structure.

F. Product Certificates: Sign ed and ealed by


C. Structural product manufacturer certifying that their
9 K45 1.5
Calculations: products comply with
COMPLIED
the specification requirements.

H. Supplier Cerificate: Cenificate issued by


the manufacturer that the fim1 is an
authorized supplier of coldformed
metal framing (non-structural metal frami
C. Structural Please refer the letter of
10 K45 1.5
Calculations:
ng) and all materials supplied are in COMPLIED confirmity attached
compliance with the
specification. and that the manufacturer is a
duly registered with Qatar Chamber of
Commerce.
(a) Galvanized Steel Sheet Components:
Comply with ASTM A1003 / A 1003M - 15a
requirements for metal, unless otherwise
NON - LOAD indicated and shown on Drawings.
11 K45 2.2 BEARING METAL COMPLIED
FRAME

(b) Protective Coating: Comply with ASTM


A653 A653 M - 1 5 for steel sheet. zinc
coated (galvanized) for
NON - LOAD corrosion resistance.
12 K45 2.2 BEARING METAL COMPLIED
FRAME

A . Studs and Runners shall be in


accordance with ASTM C754- 15 with flange
edges o f studs bent to 90 degrees and
doubled over to for 5mm wide lip - return EXMET std. provides studs
STEEL FRAMING EXMET BLUE
13 K45 2.3 and comply with the following : 23-28 COMPLIED and runner with a lip return
ASSEMBLINGS CATALOGUE
of 6 mm

(a) Minimum base metal thickness: 1 .0 mm


(39 mil ).
see exmet provides stud &
runners of thickness in the
STEEL FRAMING EXMET BLUE
14 K45 2.3
ASSEMBLINGS CATALOGUE
23-28 COMPLIED ranges 0.5 -1.2 mm .other
thickness also can be
arranged

(b) Depth: 75 mm and. or as indicated and


show n on Drawing.

STEEL FRAMING
15 K45 2.3
ASSEMBLINGS
NOTED
(c) At Door Jamb Location, walls with tile
finishes, walls suppo11ing overhead
cabinets and visual display
surfaces use 75 mm depth and, or as
STEEL FRAMING
16 K45 2.3 indicated and shown on Drawings. NOTED
ASSEMBLINGS

(c) At Door Jamb Location, walls with tile


finishes, walls suppo11ing overhead
cabinets and visual display
surfaces use 75 mm depth and, or as
STEEL FRAMING
16 K45 2.3 indicated and shown on Drawings. NOTED
ASSEMBLINGS

(d) Slip - Type Head Joints: Provide


Deflection Track on top runner
manufactured to prevent cracking
finishes applied to interior framing for
STEEL FRAMING
17 K45 2.3 partition resulting from deflection of NOTED
ASSEMBLINGS
structure above. The thickness
shall not be less than the thickness
indicated for studs and width to
accommodate depth of studs.
(e) Flat Strap and Backing Plate: Provide
steel sheet for blocking and bracing in
length and width as indicate
or shown on Drawings with minimum base
STEEL FRAMING
18 K45 2.3 metal thickness of 0.80 mm. NOTED
ASSEMBLINGS

(f) Cold-formed Channel Bridging: Provide


galvanized steel channel bridging with
minimum 1 5 mm wide
nanges, depth of 40 mm and thickness 1 .5
STEEL FRAMING
19 K45 2.3 mm. The clip angle shall be not le s than 40 NOTED
ASSEMBLINGS
mm x 40 mm and 1 .8
mm thickness.
(g) Hat - Shaped Furring: Provide galvanized
steel hat shaped funing in accordance with
ASTM C645 - 1 4 ,
minimum thickness of 0.5 mm and depth as
STEEL FRAMING
20 K45 2.3 indicated and. or shown on Drawings. NOTED
ASSEMBLINGS

(h) Cold-Formed Furrying Channels: Provide


galvanized steel cold-formed funing
channels with minimum 1 5
mm wide flanges, thickness of 1.5 mm, and
STEEL FRAMING EXMET BLUE
21 K45 2.3 depth as indicated and, or shown on 23-28 NOTED
ASSEMBLINGS CATALOGUE
Drawings. Furring brackets
shall be adjustable, corrngated-edge type
steel sheet and thickness of 0.80 mm.

(h) Cold-Formed Furrying Channels: Provide


galvanized steel cold-formed funing
channels with minimum 1 5
mm wide flanges, thickness of 1.5 mm, and
STEEL FRAMING EXMET BLUE
22 K45 2.3 depth as indicated and, or shown on 23-28 NOTED
ASSEMBLINGS CATALOGUE
Drawings. Furring brackets
shall be adjustable, cornugated-edge type
steel sheet and thickness of 0.80 mm.

(i) Tie Wire: Provide wire in accordance


witl1 ASTM A641/A64 IM - 09a(2014), Class I
zinc coating. soft
temper, 1.6 mm diameter wire, or double
STEEL FRAMING
23 K45 2.3 strand of 1 .2 mm diameter wire. NOTED
ASSEMBLINGS

A. Framing Accessories : As required for


project complying with ASTM C955 - 15e 1 .
(a) Flat strapping for flat bracing.
(b) Flat strapping and bridging for lateral
24 K45 2.5 ACCESSORIES bracing. COMPLIED
(c) Gusset plates.
(d) Flat steel sheet.
B. Shear Wall Panels : 1 5 mm thick type - X
gypsum drywall plasterboard assemblies
sheathing laminated
to 22 gauge galvanized steel sheet
25 K45 2.5 ACCESSORIES complying with ASTM A653/A653 M - 1 5. G - COMPLIED
40 galvanized coating.

C. Fasteners : Self drilling, tapping


26 K45 2.5 ACCESSORIES screw,complying with ASTM C 1513 - 13. COMPLIED

You might also like