You are on page 1of 2

Made Date Sheet

MKI 03-Nov-17 1
Check Date Rev.
ZA 04-Nov-17 0
PROJECT TITLE: KFSH & RC
LOCATION:RIYADH
DESIGN OF CORBEL
Geometrical Properties
Depth of Corbel " D " 550 mm
Width of corbel " b " 600 mm
Length of Corbel " L " 550 mm

Material Properties
Strength of concrete "fc" 35 N/mm2
Strength of steel "fy" 420 N/mm2
Clear cover to concrete 40 mm
Dia of main bars " d1 " 20 mm
Dia of vertical closed ties " d2 " 10 mm
Dia of confining ties " d3 " 10 mm
Flexure strength reduction factor 0.9
Shear strength reduction factor 0.75
1.4

Loading
Ultimate load on corbel " Vu " 218 kN

Effective depth " d " 500 mm


Distance of load from column a <=0.75L 412.5 mm
SUMMARY OF REQUIRED AND PROVIDED
REINFORCEMENT:
DescriptionRequire Provide No of Dia of bar
(mm2) (mm2) bars (mm)

Axial
2.0 CALCULATIONS: Tension 138.41 157.1 1 10
(An)
PrimARY
2.1 Check for corbel load limitation: Tension 1000 1256.8 4 20
(As)
Vnmax1 2100 KN (0.2fc b d)/1000 (11.9.3.2.1 ACI318M-02) Confining 430.79 628.4 4 10
Ties (Ah)
Vnmax2 1650 KN (5.5 b d)/1000 (11.9.3.2.1 ACI318M-02)

Vnmax 1650 KN (vnmax=MIN of Vnmax1 & Vnmax2)

Vn 290.7 KN (vu/)

Vnmax>Vu OK

2.2 Required Axial Tnsion Reinforcement:

Nu = 43.6 KN (0.2Vu)

An = 138.4 mm2 (1000 Nu)/(fy) (11.9.3.4 ACI318M-02)

Rquired No of Closed 10 mm 1 No
Vertical ties of dia
Provide 10 mm dia closed v 1 No

Provided An = 157.1 mm2

2.3 Required Shear Friction Reinforcement:

Avf = 494.3 mm2 (1000Vu)/(fy) (11.9.7.4.1 ACI318M-02)

2.4 Required Primary Tension Reinforcement:

Af = 584.8 mm2 (Vu(a) + Nu(h-d))/(fyd)


(Eq 6.8.1 PCI 5th Ed)

As1 = 723.2 mm2 (Af + An) (11.9.3.5 ACI318M-02)

As2 = 468 mm2 (2/3)Avf + An (11.9.3.5 ACI318M-02)


Made Date Sheet
MKI 03-Nov-17 1
Check Date Rev.
ZA 04-Nov-17 0
PROJECT TITLE: KFSH & RC
LOCATION:RIYADH
DESIGN OF CORBEL
Asmin = 1000 mm2 (0.04 fc/fy)/bd (11.9.5 ACI318M-02)

As = 1000 mm2 max of As1,As2 & As3

Required No 20 mm b 3.2 No
of dia

Provide 20 mm dia 4 No as main bars

Provided As = 1256.8 mm2

2.5 Required Confining Ties :

Ah = 430.8 mm2 0.5(As-An) (11.9.4 ACI318M-02)

Required No of confining 10 mm dia 2.74216


closed ties of

Provide 10 mm dia 4 No confining closed ties

Provided Ah = 628 mm2