AC Coupling with Magnum Energy

AC Coupling adds battery backup power to an


existing grid tie installation allowing the use of the
renewable energy source during a utility outage to
power the essential loads and charge the batteries.
Our goal is to provide an efficient AC coupled
system inexpensively and without changing the
existing system. --Predeep Jaltota, Sr. Engineer

Company Confidential The Powerful Difference


Company Confidential The Powerful Difference
Company Confidential The Powerful Difference
Advantages of AC Coupling in existing grid
tie systems

Higher efficiency during sell back mode (>95%)


Higher string voltages (no changes to array)
Install into existing installation (no rewiring)
Use most brands of string or micro inverters
Does not waste RE source during a utility outage
Adds battery backup to grid tie system effectively
Lower cost than separate systems
Company Confidential The Powerful Difference
Considerations when designing our AC
Coupling systems today

Battery based inverter should be 10% larger


than grid tie inverter
Some brands of GT inverters are sensitive and
disconnect from battery inverter
DC Diversion Load must be used to control
battery charging, or use a solid state voltage
relay to disconnect the PV source.
Frequency shift is used as a backup to DC
Diversion Load (failsafe feature, not primary
method) Company Confidential The Powerful Difference
How does Frequency Shift work?

IEEE Standards require tight grid frequency and


voltage tolerances in order to connect to the grid
Frequency Shift is a fail safe gap feature that
changes the output frequency of the inverter
from 60 Hz to 60.6Hz and should not be used as
the main protection for battery over-charging
Frequency Shift is enabled when battery type is
set to Custom and occurs at +1 VDC for 12v
models, +2 VDC for 24v models and + 4v for 48v
models, above the absorption voltage setting
Company Confidential The Powerful Difference
Magnum Energy Products
used with AC Coupling
MS Series (120Vac) Inverter Chargers
MS-PAE Series (120/240 VAC) Inverter Chargers
ME-ARC or ME-RTR Remotes (required)
ME-AGS-N Auto Gen Start (optional)
ME-BMK Battery Monitor Kit (optional)
ME-MW MagWeb Web Monitoring (optional)
MMP or MP - Magnum Panels (optional)

Company Confidential The Powerful Difference


ME-ARC50 Advanced Remote
Fits any MM-AE, MS, MS-AE
or RD series Inverter/Charger
Same look and feel as the simple
ME-RC50 remote
FAVS button gives quick access
to 5 favorite menus
CTRL button allows complete
control of AC input, charger and
AGS functions in one place
New setup functions for remote,
ac in, charger and AGS
Company Confidential The Powerful Difference
ME-RTR Magnum Router
Required for parallel of MS-PAE
Same look and feel as ME-ARC
4 Line LCD display
4 Cat 5 Ports for parallel
6 Ports for comm and accessories
Aux relay 2 wire voltage controlled
Supports ME-ARC second remote
No programming for parallel

Company Confidential The Powerful Difference


ME-AGS-N
Network version with ME-ARC
Manual Start/Stop from ME-ARC
Automatic Start/Stop settings for:
Battery Voltage
SOC (requires BMK option)
Load Amps
Time of Day
Temperature
Exercise Time
Features easy set clock and quiet time
adjustments
Unique Look Ahead for Quiet Time
2 wire start (momentary or maintain)
3 wire start
5 wire start
Portable mode
Company Confidential The Powerful Difference
Battery Monitor Kit
Fuel Gauge for the
inverters battery bank
12, 24, 48V applications
Features:
% of charge
Real time Amps
AHrs
Min/Max VDC

Company Confidential The Powerful Difference


MagWeb Web Monitoring
ME-MW-W Wireless
Web based
ME-MW-E Ethernet
direct Web based
Requires constantly on
internet

Company Confidential The Powerful Difference


Mini Magnum Panels MMP
Fits any MS, MS-AE, MS-PAE or RD
Series Inverter/Charger
Only 4 part numbers
175 or 250 DC breaker
30A dual or 60A single ac breaker
space for optional mini DC breakers
500A 50mv shunt
optional mounting plate
space to mount ME-RC panel
UL 1741 rated at 5kw max
Company Confidential The Powerful Difference
Magnum Panels
MPSL
MPSL Magnum Panel
Single Low Power
2 Inverters Max
60A bypass breaker
2- 175/250 DC breaker
30A Dual or 60A Single ac
input/output breakers
500A 50mv DC shunt
DC breaker options for 10
13mm or 5 back mount breakers
Company Confidential The Powerful Difference
Magnum
Panels MPSH
MPSH Magnum Panel
Single High Power
3 Inverters Max
125A bypass breaker
3- 175/250 DC breaker
30A Dual ac input/output
breakers
1000A 100mv DC shunt
n/a with 3 inverters DC
breaker option

Company Confidential The Powerful Difference


Magnum Panels MPDH
MPDH Magnum Panel
Dual High Power
4 Inverters Max
125A bypass breaker
4- 175/250 DC breaker
30A Dual ac input/output
breakers
1000A 100mv DC shunt
DC breaker options for 15
13mm or 7 back mount
breakers
Company Confidential The Powerful Difference
Company Confidential The Powerful Difference
How to setup
Frequency Shift
using the ME-ARC

Setup menu
Custom Battery
Set Absorb
Voltage
AC in Control
set to Auto
Turn off Search
Watts
The Powerful Difference
How to setup
Frequency Shift
using the ME-RTR

Setup menu
Custom Battery
Set Absorb
Voltage
AC in control
set to Auto
Turn off Parallel
Threshold
Turn off Search
Watts
The Powerful Difference
AC Coupling with our AC Diversion* Load
Controller
A networked plug and play diversion device
AC diversion loads are less expensive than DC loads
AC diversion loads are more useful than DC loads
Battery based inverter must be => PV array
Diverts away what is not required by the battery bank
True 3-stage battery charging (not in constant bulk)
Frequency shift is automatic backup to ACDL
Result: Smooth and continuous backup power
*Product is in development patents filed and pending
Company Confidential The Powerful Difference
Company Confidential The Powerful Difference
Magnum Support Team

Phone: (425) 353-8833


Fax: (425) 353-8390

www.MagnumEnergy.com
Alan@MagnumEnergy.com

Company Confidential The Powerful Difference


Company Confidential The Powerful Difference

You might also like