You are on page 1of 15

Changes to the Library in 7.0.2.

3 build 1
What is new
Added new protective device library categories:
o DC Breakers w/ Trip Unit
o DC Breakers w/o Trip Unit
o DC Breakers Molded Case
Added new devices.
Updated existing devices.

DC Devices:
DC Breakers w/ Trip Unit
Mapped existing DC protective devices to the DC breakers w/ Trip Unit section.
o SQUARE D PowerPact D-Frame, STR 53UP LSI, 150-600A, DC
o SQUARE D PowerPact D-Frame, STR23SP LS, 150-600A, DC
o UTILITY RELAY CO. ZERO-Hertz DC TU (125V) LSI, 100-5000AF, DC
o UTILITY RELAY CO. ZERO-Hertz DC TU (250V) LSI, 100-5000AF, DC
o UTILITY RELAY CO. ZERO-Hertz, DC TU LSI, 5000-12,000AF, DC

DC Breakers Molded Case


Existing DC protective devices under DC Breakers from previous version are under the DC breakers
Molded Case section.
o ABB LS 250-600A, 2-3 Poles, DC
o ABB LS 600A, 3 Pole, Magnetic Only, DC
o ALLEN-BRADLEY 140U-I3, I6 15-150A, DC
o ALLEN-BRADLEY 140U-JD3, JD6 70-250A, DC
o ALLEN-BRADLEY 140U-JDO 70-250A, DC
o ALLEN-BRADLEY 140U-K3, K6 100-400A, 3-Pole, DC
o ALLEN-BRADLEY 140U-L 250-600A, 3-4 Poles, DC
o ALLEN-BRADLEY 140U-Q3, Q6 300-600A, DC
o CUTLER-HAMMER DA 250-400A, DC
o CUTLER-HAMMER DK 250-400A, DC
o CUTLER-HAMMER EB, 1-Pole 15-100A, DC
o CUTLER-HAMMER EB, 2 & 3-Pole 15-100A, DC
o CUTLER-HAMMER ED 100-225A, DC
o CUTLER-HAMMER EDB 100-225A, DC
o CUTLER-HAMMER EDC 100-225A, DC
o CUTLER-HAMMER EDH 100-225A, DC
o CUTLER-HAMMER EDS 100-225A, DC
o CUTLER-HAMMER EHB, 1-Pole 15-100A, DC
o CUTLER-HAMMER EHB, 2 & 3-Pole 15-100A, DC
o CUTLER-HAMMER EHD 15-100A, DC
o CUTLER-HAMMER EHD, 1-Pole 15-100A, DC
o CUTLER-HAMMER FB, 2 & 3-Pole 15-150A, DC
o CUTLER-HAMMER FD 15-150A, DC
o CUTLER-HAMMER FD, 1-Pole 15-150A, DC
o CUTLER-HAMMER FDB 15-150A, DC
o CUTLER-HAMMER FDC 15-225A, DC
o CUTLER-HAMMER HFB, 1-Pole 15-100A, DC
o CUTLER-HAMMER HFB, 2 & 3-Pole 15-150A, DC
o CUTLER-HAMMER HFD 15-150A, DC
o CUTLER-HAMMER HFD, 1-Pole 15-150A, DC
o CUTLER-HAMMER HJD 0-250A, DC
o CUTLER-HAMMER HKB 70-250A, DC
o CUTLER-HAMMER HKD 100-400A, DC
o CUTLER-HAMMER HLA 70-600A, DC
o CUTLER-HAMMER HLB 70-400A, DC
o CUTLER-HAMMER HLD 300-600A, DC
o CUTLER-HAMMER HMA 125-600A, DC
o CUTLER-HAMMER HMDL 300-800A, DC
o CUTLER-HAMMER HMDLB 300-800A, DC
o CUTLER-HAMMER JA 70-225A, DC
o CUTLER-HAMMER JB 70-250A, DC
o CUTLER-HAMMER JD 70-250A, DC
o CUTLER-HAMMER JDB 70-250A, DC
o CUTLER-HAMMER JDC 70-250A, DC
o CUTLER-HAMMER KB 70-250A, DC
o CUTLER-HAMMER KD 100-400A, DC
o CUTLER-HAMMER KDB 100-400A, DC
o CUTLER-HAMMER KDC 100-400A, DC
o CUTLER-HAMMER LA 70-600A, DC
o CUTLER-HAMMER LAB 125-400A, DC
o CUTLER-HAMMER LB 70-400A, DC
o CUTLER-HAMMER LBB 125-400A, DC
o CUTLER-HAMMER LD 300-600A, DC
o CUTLER-HAMMER LDB 300-600A, DC
o CUTLER-HAMMER LDC 300-600A, DC
o CUTLER-HAMMER LHH, Series G LG Frame 125-400A, DC
o CUTLER-HAMMER MA 125-600A, DC
o CUTLER-HAMMER MDL 300-800A, DC
o CUTLER-HAMMER MDLB 300-800A, DC
o GREEGOO GM3 100-250A, DC
o MITSUBISHI NF100-CWU 50-100A, DC
o MITSUBISHI NF100-SWU 15-100A, DC
o MITSUBISHI NF225-CWU 125-225A, DC
o SIEMENS EG Frame, HEG/HEB 15-125A, DC
o SIEMENS EG Frame, NEG/NEB 15-125A, DC
o SQUARE D KA 70-250A, DC
o SQUARE D KH 70-100A, DC
o SQUARE D KH 70-250A, DC
o SQUARE D LA 125-400A, DC
o SQUARE D LH 125-400A, DC
o SQUARE D MA 125-1200A, DC
o SQUARE D MH 125-1200A, DC
o TERASAKI TemBreak XS100NS 15-100A, 2-4 Poles, DC
o TERASAKI TemBreak XS400 125-400A, 3-4 Poles, DC
o WESTINGHOUSE HKA 70-225A, DC
o WESTINGHOUSE HKB 70-250A, DC
o WESTINGHOUSE HLA 125-600A, DC
o WESTINGHOUSE HLA 70-400A, DC
o WESTINGHOUSE HLB 70-400A, DC
o WESTINGHOUSE JA, KA 70-225A, DC
o WESTINGHOUSE JB, KB 70-250A, DC
o WESTINGHOUSE LAB, LA 125-600A, DC
o WESTINGHOUSE LBB, LB 70-400A, DC
DC Breakers w/o Trip Unit
New Devices:
BUSSMANN PV, Class gPV 1-20A, IEC

Fuses:
Low-Voltage Fuses:
New Devices:
LITTELFUSE BLF 0.5-30A

High-Voltage Fuses:
New Devices:
HI-TECH TRANS-GUARD EX, 5.5kV 80-200A

Changes to the Library in 7.0.2.2 build 1


What is new
Added new devices.
Updated existing devices.

DC Devices:
DC Fuses
New Devices:
BUSSMANN PV, Class gPV 1-20A, IEC
BUSSMANN PV, Class UL PV 1-15A, UL
BUSSMANN PV, Class gPV 15-32A, IEC

Switches:
Automatic Transfer Switch
New Devices:
KOHLER KCS/KCP 30-4000A, For Any CB
KOHLER KCS/KCP 30-4000A, For Current Limiting Fuses
KOHLER KCS/KCP 70-1200A, For Specific CB

Low Voltage Breakers:


Static Trip Breakers:
Modified Devices:

CUTLER-HAMMER CHKD, Optim 550/1050 LS (LTD=I4t), 63-400A


CUTLER-HAMMER CHKD, Optim 550/1050 LS, 63-400A
CUTLER-HAMMER CHKD, Optim 550/1050 LSI (LTD=I4t), 63-400A
CUTLER-HAMMER CHKD, Optim 550/1050 LSI, 63-400A
CUTLER-HAMMER CKD, Optim 550/1050 LS (LTD=I4t), 63-400A
CUTLER-HAMMER CKD, Optim 550/1050 LS, 63-400A
CUTLER-HAMMER CKD, Optim 550/1050 LSI (LTD=I4t), 63-400A
CUTLER-HAMMER CKD, Optim 550/1050 LSI, 63-400A
CUTLER-HAMMER HKD, Optim 550/1050 LS (LTD=I4t), 63-400A
CUTLER-HAMMER HKD, Optim 550/1050 LS, 63-400A
CUTLER-HAMMER HKD, Optim 550/1050 LSI (LTD=I4t), 63-400A
CUTLER-HAMMER HKD, Optim 550/1050 LSI, 63-400A
CUTLER-HAMMER KD, Optim 550/1050 LS (LTD=I4t), 63-400A
CUTLER-HAMMER KD, Optim 550/1050 LS, 63-400A
CUTLER-HAMMER KD, Optim 550/1050 LSI (LTD=I4t), 63-400A
CUTLER-HAMMER KD, Optim 550/1050 LSI, 63-400A
CUTLER-HAMMER KDC, Optim 550/1050 LS (LTD=I4t), 63-400A
CUTLER-HAMMER KDC, Optim 550/1050 LS, 63-400A
CUTLER-HAMMER KDC, Optim 550/1050 LSI (LTD=I4t), 63-400A
CUTLER-HAMMER KDC, Optim 550/1050 LSI, 63-400A
-Updated the breaker name from Optim 550 to Optim 550/1050. Mapped old name to the new
name.

CUTLER-HAMMER CHMDL, RMS 310 (06/07) LS, 400-800A Adj Plug


CUTLER-HAMMER CHMDL, RMS 310 (06/07) LS, 400-800A Fixed Plug
CUTLER-HAMMER CHMDL, RMS 310 (06/07) LSI, 400-800A Adj Plug
CUTLER-HAMMER CHMDL, RMS 310 (06/07) LSI, 400-800A Fixed Plug
CUTLER-HAMMER CMDL, RMS 310 (06/07) LS, 400-800A Adj Plug
CUTLER-HAMMER CMDL, RMS 310 (06/07) LS, 400-800A Fixed Plug
CUTLER-HAMMER CMDL, RMS 310 (06/07) LSI, 400-800A Adj Plug
CUTLER-HAMMER CMDL, RMS 310 (06/07) LSI, 400-800A Fixed Plug
CUTLER-HAMMER HMDL, RMS 310 (06/07) LS, 400-800A Adj Plug
CUTLER-HAMMER HMDL, RMS 310 (06/07) LS, 400-800A Fixed Plug
CUTLER-HAMMER HMDL, RMS 310 (06/07) LSI, 400-800A Adj Plug
CUTLER-HAMMER HMDL, RMS 310 (06/07) LSI, 400-800A Fixed Plug
CUTLER-HAMMER HMDLB, RMS 310 (06/07) LS, 400-800A
CUTLER-HAMMER HMDLB, RMS 310 (06/07) LSI, 400-800A
CUTLER-HAMMER MDL, RMS 310 (06/07) LS, 400-800A Adj Plug
CUTLER-HAMMER MDL, RMS 310 (06/07) LS, 400-800A Fixed Plug
CUTLER-HAMMER MDL, RMS 310 (06/07) LSI, 400-800A Adj Plug
CUTLER-HAMMER MDL, RMS 310 (06/07) LSI, 400-800A Fixed Plug
CUTLER-HAMMER MDLB, RMS 310 (06/07) LS, 400-800A Fixed Plug
CUTLER-HAMMER MDLB, RMS 310 (06/07) LSI, 400-800A Fixed Plug
-Mapped the old M-Frame breakers with RMS 310 trip unit (eg. MDL, RMS 310) to the updated
breakers, eg. MDL, RMS 310 (06/07).

Ground Fault Breakers:


Modified Devices:
CUTLER-HAMMER CHKD, Optim 550/1050 GF, 63-400A
CUTLER-HAMMER CKD, Optim 550/1050 GF, 63-400A
CUTLER-HAMMER HKD, Optim 550/1050 GF, 63-400A
CUTLER-HAMMER KD, Optim 550/1050 GF, 63-400A
CUTLER-HAMMER KDC, Optim 550/1050 GF, 63-400A
-Updated the breaker name from Optim 550 to Optim 550/1050. Mapped old name to the new
name.

HV/MV Breakers:
With Integral Trip:
Modified Devices:
CUTLER-HAMMER T-VAC / T-VACR, Digitrip 1150V LSI, 100-2500AP, IEC
CUTLER-HAMMER VCP-T / VCP-TR, Digitrip 1150V LSI, 100-2500AP
-Updated the library model with inverse curve modifications.
Changes to the Library in 7.0.1.1 build 1
What is new
Updated existing devices.
Updated and compressed the PTW.lib file for a more efficient functionality.

Low Voltage Breakers:


Static Trip Breakers:
Modified Devices:

SQUARE D Powerpact H-Frame, 5.2A/E & 6.2A/E LSI, 100AS


SQUARE D Powerpact H-Frame, 5.2A/E & 6.2A/E LSI, 150AS
SQUARE D Powerpact H-Frame, 5.2A/E & 6.2A/E LSI, 60AS
SQUARE D Powerpact J Frame, 5.2A/E & 6.2A/E LSI, 250AS
SQUARE D Powerpact L-Frame, 5.3A/E & 6.3A/E LSI, 400AS
SQUARE D Powerpact L-Frame, 5.3A/E & 6.3A/E LSI, 600AS
-Updated the breaker to enable the data block to show the settings accordingly.

Changes to the Library in 7.0


What is new
Added new device components:
o Solar PV
o Motor Nameplates
o DC Devices
Added a new feature in which the user can link external documents to a library device entry.
Added new breakers, relays, and fuses and updated several existing devices.
Updated the IEE Wiring Cable to the 17th Edition.

Low Voltage Breakers:


Static Trip Breakers:
New Devices:

CUTLER-HAMMER NRX, Digitrip 520/520M LSI, 200-1200AP

SIEMENS WL, ETU725, Size I LSI, 200-1200AP, UL


SIEMENS WL, ETU725, Size II LSI, 200-3000AP, UL
SIEMENS WL, ETU725, Size III LSI, 800-5000AP, UL
SIEMENS WL, ETU727, Size I LSI, 200-1200AP, UL
SIEMENS WL, ETU727, Size II LSI, 200-3000AP, UL
SIEMENS WL, ETU727, Size III LSI, 800-5000AP, UL
SIEMENS WL, ETU745, Size I LSI, 200-1200AP, UL
SIEMENS WL, ETU745, Size II LSI, 200-3000AP, UL
SIEMENS WL, ETU745, Size III LSI, 800-5000AP, UL
SIEMENS WL, ETU748, Size I LS, 200-1200AP, UL
SIEMENS WL, ETU748, Size II LS, 200-3000AP, UL
SIEMENS WL, ETU748, Size III LS, 800-5000AP, UL
SIEMENS WL, ETU755 Size II LSI, 200-3000AP, UL
SIEMENS WL, ETU755 Size III LSI, 800-5000AP, UL
SIEMENS WL, ETU776, Size II LSI, 200-3000AP, UL
SIEMENS WL, ETU776, Size III LSI, 800-5000AP, UL
-Added UL 489 versions

SQUARE D PowerPact H-Frame, 3.2 LI, 100AS


SQUARE D PowerPact H-Frame, 3.2 LI, 150AS
SQUARE D PowerPact H-Frame, 3.2 LI, 60AS
SQUARE D PowerPact H-Frame, 3.2S LSI, 100AS
SQUARE D PowerPact H-Frame, 3.2S LSI, 150AS
SQUARE D PowerPact H-Frame, 3.2S LSI, 60AS
SQUARE D Powerpact H-Frame, 5.2A/E & 6.2A/E LSI, 100AS
SQUARE D Powerpact H-Frame, 5.2A/E & 6.2A/E LSI, 150AS
SQUARE D Powerpact H-Frame, 5.2A/E & 6.2A/E LSI, 60AS
SQUARE D Powerpact J Frame, 5.2A/E & 6.2A/E LSI, 250AS
SQUARE D PowerPact J-Frame, 3.2 LI, 250AS
SQUARE D PowerPact J-Frame, 3.2S LSI, 250AS
SQUARE D PowerPact L-Frame, 3.3 LI, 250AS
SQUARE D PowerPact L-Frame, 3.3 LI, 400AS
SQUARE D PowerPact L-Frame, 3.3 LI, 600AS
SQUARE D PowerPact L-Frame, 3.3S LSI, 250AS
SQUARE D PowerPact L-Frame, 3.3S LSI, 400AS
SQUARE D PowerPact L-Frame, 3.3S LSI, 600AS
SQUARE D Powerpact L-Frame, 5.3A/E & 6.3A/E LSI, 400AS
SQUARE D Powerpact L-Frame, 5.3A/E & 6.3A/E LSI, 600AS

Modified Devices:
CUTLER-HAMMER FDE/FDCE/HFDE, 310+ LS, 80-225A, UL
CUTLER-HAMMER FDE/FDCE/HFDE, 310+ LSI, 80-225A, UL
-Updated per manufacturer recommendation. I2T is locked for LS and is the only available setting.
Similarly, LSI only has Flat short delay settings. Implemented device mapping from the old
library to the new entry.

CUTLER-HAMMER NRX, Digitrip 520/520M LSI, 200-800AP, UL


-Corrected the Maximum Voltage description from 600V to 635V.

SIEMENS WL, ETU745, Size II GF, 200-3200AP


SIEMENS WL, ETU745, Size III GF, 800-5000AP
SIEMENS WL, ETU748, Size I GF, 200-1200AP
SIEMENS WL, ETU748, Size II GF, 200-3200AP
SIEMENS WL, ETU748, Size III GF, 800-5000AP
-Corrected the Ground Fault Delay (tg) setting descriptions. Implemented device mapping for the
change.

Ground Fault Breakers:


New Devices:
CUTLER-HAMMER NRX, Digitrip 520/520M GF, 200-1200AP
SIEMENS WL, ETU727, Size I GF, 200-1200AP, UL
SIEMENS WL, ETU727, Size II GF, 200-3000AP, UL
SIEMENS WL, ETU727, Size III GF, 800-5000AP, UL
SIEMENS WL, ETU745, Size I GF, 200-1200AP, UL
SIEMENS WL, ETU745, Size II GF, 200-3000AP, UL
SIEMENS WL, ETU745, Size III GF, 200-3000AP, UL
SIEMENS WL, ETU748, Size I GF, 200-1200AP, UL
SIEMENS WL, ETU748, Size II GF, 200-3000AP, UL
SIEMENS WL, ETU748, Size III GF, 800-5000AP, UL
SIEMENS WL, ETU755 Size II GF, 200-3000AP, UL
SIEMENS WL, ETU755 Size III GF, 800-5000AP, UL
SIEMENS WL, ETU776, Size II GF, 200-3000AP, UL
SIEMENS WL, ETU776, Size III GF, 800-5000AP, UL
-Added UL 489 versions

SQUARE D Powerpact H-Frame, 6.2A/E GF, 100AS


SQUARE D Powerpact H-Frame, 6.2A/E GF, 150AS
SQUARE D Powerpact H-Frame, 6.2A/E GF, 60AS
SQUARE D Powerpact J-Frame, 6.2A/E GF, 250AS
SQUARE D Powerpact L-Frame, 6.3A/E GF, 400AS
SQUARE D Powerpact L-Frame, 6.3A/E GF, 600AS

Modified Devices:
CUTLER-HAMMER FDE/FDCE/HFDE, 310+ GF, 80-225A
-Updated setting names for clarity and readability. Implemented device mapping for the change.

Thermal Magnetic Molded Case Breakers:


New Devices:
FUJI BU-FSB 15-150A, 2-3 poles
FUJI BU-ESB 15-100A, 2-3 Poles
FUJI BU-ECA 5-100A, 2-3 Poles

Modified Devices:
CUTLER-HAMMER FD 15-225A
-Updated the kAIC rating at 480V to 35kA. Pre-2001 kAIC rating of 25kA is retained.

CUTLER-HAMMER GD 15-100A, 2-3 Pole


CUTLER-HAMMER GHB 15-100A, 1-Pole
CUTLER-HAMMER GHB 15-100A, 2-3 Pole
CUTLER-HAMMER GHC 15-100A, 1-Pole
CUTLER-HAMMER GHC 15-100A, 2-3 Pole
-Updated Time-Current Curve. Implemented device mapping from the old library to the new
entry.

Motor/Gen Protection:

Motor relays:
New devices:

CUTLER-HAMMER MP-4000 Motor Protection


CUTLER-HAMMER MP-4000 (G) Motor Protection

EATON EMR-4000 50/51P


EATON EMR-4000 50/51R
EATON EMR-4000 50/51X

Modified devices:

EATON ETR-4000 50/51P


EATON ETR-4000 50/51R
EATON ETR-4000 50/51X
-Modified pickup range per manufacturer recommendation. Implemented device mapping from
the old library to the new entry.

Fuses:
Low-Voltage Fuses:
New Devices:
BUSSMANN FWP 20-100A

High-Voltage Fuses:
New Devices:
ABB DO-III Dual Sensing 3-65A (G3-G14)

CUTLER-HAMMER DBU, 17.1kV, E-Rated 5E-200E, Standard Speed


CUTLER-HAMMER DBU, 27/38kV, E-Rated 5E-200E, Standard Speed
CUTLER-HAMMER RBA, RDB-200, 2.4-34.5kV E-Rated 10E-200E Std Speed w/ Filter
CUTLER-HAMMER RBA, RDB-200, 2.4-34.5kV E-Rated 20E-200E Time Lag w/ Filter
CUTLER-HAMMER RBA, RDB-400, 2.4-34.5kV E-Rated 20E-200E Time Lag w/ Filter
CUTLER-HAMMER RBA, RDB-400, 2.4-34.5kV E-Rated 250-400E Time Lag w/ Filter
CUTLER-HAMMER RBA, RDB-400, 2.4-34.5kV E-Rated 3E-400E Std Speed w/ Filter
CUTLER-HAMMER RBA, RDB-800, 4.16-34.5kV E-Rated 450E-720E Std Speed w/ Filter
CUTLER-HAMMER RBA, RDB-800, 4.16-34.5kV E-Rated 450E-720E Time Lag w/ Filter

HI-TECH TRANS-GUARD OS, HTDS, 15.5kV 35-300A


HI-TECH TRANS-GUARD OS, HTDS, 23kV 40-175A
HI-TECH TRANS-GUARD OS, HTDS, 8.3kV 35-300A
HI-TECH TRANS-GUARD EX, 15.5kV 6-100A

MERSEN 9F60 EJ0-1, 2.75 & 5.5kV E-Rated 1E-200E


MERSEN 9F60 EJ0-1, 25.8kV E-Rated 1E-100E
MERSEN 9F60 EJ-1, 15.5kV E-Rated 2E-10E
MERSEN 9F60 EJ-1, 15kV E-Rated 125E-175E
MERSEN 9F60 EJ-1, 2.75kV E-Rated 1E-200E
MERSEN 9F60 EJ-1, 25.8kV E-Rated 1E-2E
MERSEN 9F60 EJ-1, 5.5kV E-Rated 1E-25E
MERSEN 9F60 EJ-2, 2.54 & 5.08kV R-Rated 2R-36R
MERSEN 9F60 EJ0-1, 15.5kV E-Rated 1E-100E
MERSEN 9F60 EJ0-1, 38kV E-Rated 1E-80E
MERSEN 9F60 EJ0-1, 8.25kV E-Rated 1E-200E
MERSEN 9F60 EJ0-5, 5.5-9.52kV 15-40A
MERSEN 9F62 EJ0-1, 15.5kV E-Rated 20E-200E
MERSEN 9F62 EJ0-1, 5.5kV 25-450A
MERSEN 9F62 EJ0-1, 8.3kV E-Rated 20E-250E

SIBA HHD - 292mm Backup, 10-24kV 6.3-63A


SIBA HHD - 442mm Backup, 10-24kV 6.3-200A
SIBA HHD - 537mm Backup, 10-24kV 6.3-200A

SQUARE D 15.5GXQSJD, 15.5kV, E-Rated 175E-200E


SQUARE D 17.5GDMSJD, 17.5kV, E-Rated 10E-30E
SQUARE D 17.5GFMSJD, 17.5kV, E-Rated 40E-65E
SQUARE D 17.5GXMSJD, 17.5kV, E-Rated 80E-100E
SQUARE D 17.5GXQSJD, 17.5kV, E-Rated 125E-150E
SQUARE D 55GDMSJD, 5.5kV, E-Rated 10E-125E
SQUARE D 55GFMSJD, 5.5kV, E-Rated 150E-450E
SQUARE D 15.5GXQSJD, 15.5kV E-Rated 2x175E - 2x200E
SQUARE D 17.5GDMSJD, 17.5kV E-Rated 2x10E - 2x30E
SQUARE D 17.5GFMSJD, 17.5kV E-Rated 2x40E - 2x65E
SQUARE D 17.5GXMSJD, 17.5kV E-Rated 2x80E - 2x100E
SQUARE D 17.5GXQSJD, 17.5kV E-Rated 2x125E - 2x150E
SQUARE D 55GDMSJD, 5.5kV, E-Rated 2x10E - 2x125E
SQUARE D 55GFMSJD, 5.5kV, E-Rated 2x150E - 2x450E

Relays:
Electronic Relays:
New Devices:
EATON EDR-3000 50/51R
EATON EDR-4000 50/51R
EATON EDR-5000 50/51R

Modified Devices:
EATON EDR-3000 50/51P
EATON EDR-3000 50/51X
EATON EDR-4000 50/51P/51V
EATON EDR-4000 50/51X
EATON EDR-5000 50/51P/51V
EATON EDR-5000 50/51X
-Updated the setting ranges of the relay and added new functions. Implemented device mapping
from the old library to the new entry.

HV/MV Breakers:
Without Integral Trip:
Modified Devices:
CUTLER-HAMMER VCP-W 600-3000A
-added new part numbers
50 VCP-W 50 4760 1.00 1200.0 1200.0
50 VCP-W 40 4760 1.00 1200.0 1200.0
50 VCP-W 25 4760 1.00 1200.0 1200.0
50 VCP-W 63 4760 1.00 1200.0 1200.0
75 VCP-W 40 8250 1.00 1200.0 1200.0
75 VCP-W 50 8250 1.00 1200.0 1200.0
150 VCP-W 50 15000 1.00 1200.0 1200.0
150 VCP-W 63 15000 1.00 1200.0 1200.0
150 VCP-W 40 15000 1.00 1200.0 1200.0
150 VCP-W 25 15000 1.00 1200.0 1200.0
50 VCP-W 50 4760 1.00 2000.0 2000.0
50 VCP-W 63 4760 1.00 2000.0 2000.0
50 VCP-W 40 4760 1.00 2000.0 2000.0
50 VCP-W 25 4760 1.00 2000.0 2000.0
75 VCP-W 50 8250 1.00 2000.0 2000.0
75 VCP-W 40 8250 1.00 2000.0 2000.0
150 VCP-W 50 15000 1.00 2000.0 2000.0
150 VCP-W 40 15000 1.00 2000.0 2000.0
150 VCP-W 25 15000 1.00 2000.0 2000.0
150 VCP-W 63 15000 1.00 2000.0 2000.0
50 VCP-W 25 4760 1.00 3000.0 3000.0
50 VCP-W 63 4760 1.00 3000.0 3000.0
50 VCP-W 50 4760 1.00 3000.0 3000.0
50 VCP-W 40 4760 1.00 3000.0 3000.0
75 VCP-W 50 8250 1.00 3000.0 3000.0
75 VCP-W 40 8250 1.00 3000.0 3000.0
150 VCP-W 40 15000 1.00 3000.0 3000.0
150 VCP-W 25 15000 1.00 3000.0 3000.0
150 VCP-W 50 15000 1.00 3000.0 3000.0

Bus:
New Devices:
CUTLER-HAMMER Pow-R-Line 3E 100-600A

DC Devices:
DC Breakers
New Devices:
FUJI BU-ECA 5-100A, DC

Mapped existing DC protective devices to the DC breakers section.


o ABB LS 250-600A, 2-3 Poles, DC
o ABB LS 600A, 3 Pole, Magnetic Only, DC
o ALLEN-BRADLEY 140U-I3, I6 15-150A, DC
o ALLEN-BRADLEY 140U-JD3, JD6 70-250A, DC
o ALLEN-BRADLEY 140U-JDO 70-250A, DC
o ALLEN-BRADLEY 140U-K3, K6 100-400A, 3-Pole, DC
o ALLEN-BRADLEY 140U-L 250-600A, 3-4 Poles, DC
o ALLEN-BRADLEY 140U-Q3, Q6 300-600A, DC
o CUTLER-HAMMER DA 250-400A, DC
o CUTLER-HAMMER DK 250-400A, DC
o CUTLER-HAMMER EB, 1-Pole 15-100A, DC
o CUTLER-HAMMER EB, 2 & 3-Pole 15-100A, DC
o CUTLER-HAMMER ED 100-225A, DC
o CUTLER-HAMMER EDB 100-225A, DC
o CUTLER-HAMMER EDC 100-225A, DC
o CUTLER-HAMMER EDH 100-225A, DC
o CUTLER-HAMMER EDS 100-225A, DC
o CUTLER-HAMMER EHB, 1-Pole 15-100A, DC
o CUTLER-HAMMER EHB, 2 & 3-Pole 15-100A, DC
o CUTLER-HAMMER EHD 15-100A, DC
o CUTLER-HAMMER EHD, 1-Pole 15-100A, DC
o CUTLER-HAMMER FB, 2 & 3-Pole 15-150A, DC
o CUTLER-HAMMER FD 15-150A, DC
o CUTLER-HAMMER FD, 1-Pole 15-150A, DC
o CUTLER-HAMMER FDB 15-150A, DC
o CUTLER-HAMMER FDC 15-225A, DC
o CUTLER-HAMMER HFB, 1-Pole 15-100A, DC
o CUTLER-HAMMER HFB, 2 & 3-Pole 15-150A, DC
o CUTLER-HAMMER HFD 15-150A, DC
o CUTLER-HAMMER HFD, 1-Pole 15-150A, DC
o CUTLER-HAMMER HJD 0-250A, DC
o CUTLER-HAMMER HKB 70-250A, DC
o CUTLER-HAMMER HKD 100-400A, DC
o CUTLER-HAMMER HLA 70-600A, DC
o CUTLER-HAMMER HLB 70-400A, DC
o CUTLER-HAMMER HLD 300-600A, DC
o CUTLER-HAMMER HMA 125-600A, DC
o CUTLER-HAMMER HMDL 300-800A, DC
o CUTLER-HAMMER HMDLB 300-800A, DC
o CUTLER-HAMMER JA 70-225A, DC
o CUTLER-HAMMER JB 70-250A, DC
o CUTLER-HAMMER JD 70-250A, DC
o CUTLER-HAMMER JDB 70-250A, DC
o CUTLER-HAMMER JDC 70-250A, DC
o CUTLER-HAMMER KB 70-250A, DC
o CUTLER-HAMMER KD 100-400A, DC
o CUTLER-HAMMER KDB 100-400A, DC
o CUTLER-HAMMER KDC 100-400A, DC
o CUTLER-HAMMER LA 70-600A, DC
o CUTLER-HAMMER LAB 125-400A, DC
o CUTLER-HAMMER LB 70-400A, DC
o CUTLER-HAMMER LBB 125-400A, DC
o CUTLER-HAMMER LD 300-600A, DC
o CUTLER-HAMMER LDB 300-600A, DC
o CUTLER-HAMMER LDC 300-600A, DC
o CUTLER-HAMMER LHH, Series G LG Frame 125-400A, DC
o CUTLER-HAMMER MA 125-600A, DC
o CUTLER-HAMMER MDL 300-800A, DC
o CUTLER-HAMMER MDLB 300-800A, DC
o GREEGOO GM3 100-250A, DC
o MITSUBISHI NF100-CWU 50-100A, DC
o MITSUBISHI NF100-SWU 15-100A, DC
o MITSUBISHI NF225-CWU 125-225A, DC
o SIEMENS EG Frame, HEG/HEB 15-125A, DC
o SIEMENS EG Frame, NEG/NEB 15-125A, DC
o SQUARE D KA 70-250A, DC
o SQUARE D KH 70-100A, DC
o SQUARE D KH 70-250A, DC
o SQUARE D LA 125-400A, DC
o SQUARE D LH 125-400A, DC
o SQUARE D MA 125-1200A, DC
o SQUARE D MH 125-1200A, DC
o TERASAKI TemBreak XS100NS 15-100A, 2-4 Poles, DC
o TERASAKI TemBreak XS400 125-400A, 3-4 Poles, DC
o WESTINGHOUSE HKA 70-225A, DC
o WESTINGHOUSE HKB 70-250A, DC
o WESTINGHOUSE HLA 125-600A, DC
o WESTINGHOUSE HLA 70-400A, DC
o WESTINGHOUSE HLB 70-400A, DC
o WESTINGHOUSE JA, KA 70-225A, DC
o WESTINGHOUSE JB, KB 70-250A, DC
o WESTINGHOUSE LAB, LA 125-600A, DC
o WESTINGHOUSE LBB, LB 70-400A, DC

DC Fuses

Mapped existing DC protective devices to the DC Fuses section.


o BUSSMANN FRN-R, Class RK5 0.1-600A, DC
o BUSSMANN FWJ 35-600A, DC
o EDISON TJN, Class T 15-600A, DC
o EDISON TJS, Class T 15-400A, DC
o LAWSON N&T, Class gG 2-800A, DC

Solar PV Module:

o BP SOLAR BP 3170B
o BP SOLAR BP 3220T
o BP SOLAR BP 3225T
o BP SOLAR BP 3230T
o BULL POWERTECH BPT M5 200
o BULL POWERTECH BPT P6 235 EUROPE
o BULL POWERTECH BPT P6 245
o CN SOLAR CNM 135P-36
o CN SOLAR CNM 180M-72
o CN SOLAR CNM 200P-54
o CN SOLAR CNM 230M-96
o CN SOLAR CNM 230P-60
o CN SOLAR CNM 280P-72
o CP-SOLAR CPS-185M-Transparent
o CP-SOLAR CPS-185W-LAMINATED
o CP-SOLAR CPS-185W-ULTRA
o CP-SOLAR CPS-190M
o CP-SOLAR CPS-190M-Transparent
o CP-SOLAR CPS-195M
o CP-SOLAR CPS-230P
o CP-SOLAR CPS-230P-LAMINATED
o CP-SOLAR CPS-230P-Red
o CP-SOLAR CPS-235P
o CP-SOLAR CPS-240M
o CP-SOLAR CPS-240P
o CP-SOLAR CPS-245M
o CP-SOLAR CPS-280P
o CP-SOLAR CPS-Black-185M
o CP-SOLAR CPS-Black-185M-Laminated
o EKARAT SOLAR ES1200
o EKARAT SOLAR ES1210
o ENN SOLAR ENERGY EST-110
o ENN SOLAR ENERGY EST-115
o ENN SOLAR ENERGY EST-120
o ENN SOLAR ENERGY EST-125
o ENN SOLAR ENERGY EST-130
o ENN SOLAR ENERGY EST-135
o ENN SOLAR ENERGY EST-440
o ENN SOLAR ENERGY EST-460
o ENN SOLAR ENERGY EST-480
o ENN SOLAR ENERGY EST-500
o ENN SOLAR ENERGY EST-520
o ENN SOLAR ENERGY EST-540
o KYOCERA SOLAR FC130GX-2P
o KYOCERA SOLAR FD135GH-2P RI
o SANYO HIP-186BA19
o SANYO HIP-186BA20
o SANYO HIP-186DA3
o SANYO HIP-190BA19
o SANYO HIP-190BA20
o SANYO HIP-190DA3
o SANYO HIP-195BA19
o SANYO HIP-195BA20
o SANYO HIP-195DA3
o SANYO HIP-200BA19
o SANYO HIP-200BA20
o SANYO HIP-205BA19
o SANYO HIP-205BA20
o SANYO HIP-205NKHA5
o SANYO HIP-205NKHA6
o SANYO HIP-210NKHA5
o SANYO HIP-210NKHA6
o SANYO HIP-215NKHA5
o SANYO HIP-215NKHA6
o SANYO HIP-215NKHE5
o SANYO HIT-240HDE4
o KYOCERA SOLAR KC130GH-2P
o KYOCERA SOLAR KC175GH-2P
o KYOCERA SOLAR KC200GH-2P
o KYOCERA SOLAR KC40GX-2P
o KYOCERA SOLAR KC50GX-2P
o KYOCERA SOLAR KC65GX-2P
o KYOCERA SOLAR KC85GX-2P
o KYOCERA SOLAR KC85SX-1P
o KYOCERA SOLAR KD135GH-2PU
o KYOCERA SOLAR KD135SX-1PU
o KYOCERA SOLAR KD140GH-2PU
o KYOCERA SOLAR KD185GH-2PU
o KYOCERA SOLAR KD190GH-2PU
o KYOCERA SOLAR KD210GH-2PU
o KYOCERA SOLAR KD215GH-2PU
o KYOCERA SOLAR KD235GH-2PB
o KYOCERA SOLAR KD240GH-2PB
o KYOCERA SOLAR KD50SE-1P
o KYOCERA SOLAR KD70SX-1P
o KYOCERA SOLAR KD95SX-1P
o KOTAK URJA KM0185 (54 Cells)
o KOTAK URJA KM0185 (60 Cells)
o KOTAK URJA KM0185 (72 Cells)
o KOTAK URJA KM0190 (54 Cells)
o KOTAK URJA KM0190 (60 Cells)
o KOTAK URJA KM0190 (72 Cells)
o KOTAK URJA KM0195
o KOTAK URJA KM0200 (54 Cells)
o KOTAK URJA KM0200 (60 Cells)
o KOTAK URJA KM0205
o KOTAK URJA KM0210
o KOTAK URJA KM0215
o KOTAK URJA KM0220
o KOTAK URJA KM0225 (60 Cells)
o KOTAK URJA KM0225 (72 Cells)
o KOTAK URJA KM0230 (60 Cells)
o KOTAK URJA KM0230 (72 Cells)
o KOTAK URJA KM0235 (60 Cells)
o KOTAK URJA KM0235 (72 Cells)
o KOTAK URJA KM0240
o KOTAK URJA KM0245
o KOTAK URJA KM0250
o KOTAK URJA KM0260
o KOTAK URJA KM0265
o KOTAK URJA KM0270
o LORENTZ LA100-12S
o LORENTZ LA30-12S
o LORENTZ LA80-12S
o LORENTZ LA95-12S
o LORENTZ LC120-12P
o LORENTZ LC175-24M
o LORENTZ LC20-12M
o LORENTZ LC40-12M
o LORENTZ LC50-12M
o LORENTZ LC80-12M
o MARTIFER SOLAR MTS 215P
o MARTIFER SOLAR MTS 220P
o MARTIFER SOLAR MTS 225P
o MARTIFER SOLAR MTS 230P
o MARTIFER SOLAR MTS 235P
o MARTIFER SOLAR MTS 240P
o SHARP NA-V115H5
o SHARP NA-V121H5
o SHARP NA-V128H5
o SHARP ND-123UJF
o SHARP ND-130UJF
o SHARP ND-162U1
o SHARP ND-162U1F
o SHARP ND-162U1Y
o SHARP ND-167U1
o SHARP ND-167U1F
o SHARP ND-167U1Y
o SHARP ND-167U3
o SHARP ND-167U3A
o SHARP ND-176U1Y
o SHARP ND-176UC1
o SHARP ND-187U1
o SHARP ND-187U1F
o SHARP ND-198UC1
o SHARP ND-200U1F
o SHARP ND-200U2
o SHARP ND-205U1
o SHARP ND-208U1
o SHARP ND-208U1F
o SHARP ND-208U2
o SHARP ND-208UC1
o SHARP ND-224U1F
o SHARP ND-224UC1
o SHARP ND-62RU1
o SHARP ND-62RU2
o SHARP ND-N2ECUC
o SHARP NE-170UC1
o SHARP NE-80EJEA
o SHARP NT-175UC1
o SHARP NU-U230F3
o SHARP NU-U235F1
o MITSUBISHI ELECTRIC PV-EE130MF5F
o MITSUBISHI ELECTRIC PV-MF125UE4N
o MITSUBISHI ELECTRIC PV-MF180UD4
o MITSUBISHI ELECTRIC PV-UD180MF5
o MITSUBISHI ELECTRIC PV-UD185MF5
o MITSUBISHI ELECTRIC PV-UE125MF5N
o S-ENERGY SM-165PA0
o S-ENERGY SM-200PK0
o S-ENERGY SM-220PK0
o S-ENERGY SM-224PJ0
o S-ENERGY SM-232MH0
o S-ENERGY SM-240MH0

Motor Nameplate/Loading Table:

o TECO-WESTINGHOUSE 3P ODP
o TECO-WESTINGHOUSE (Medium Voltage)