You are on page 1of 21

SECTION - A

FIELD INVESTIGATIONS
Excavation of test pits upto a maximum depth of 3m below top of ground including
backfilling of pits to original condition.
Collection of undisturbed block samples (30cmx30cmx30cm) from testpits including
their waxing, labelling, packing, storage & transportation to an approved laboratory.
I
Performance of field density tests by sand replacement method in test pits generally
@ 2 tests/pit at selected horizons including ' collection of small disturbed samples
(stleast 2 Nos.) in moisture tins along with determination of moisture content and '
transportation of samples to the laboratory.
Collection of water samples (if encountered) from test pits including their labelling,
packing, storage and transportation to an approved testing laboratory.
SECTION - B

LABORATORY TESTING

Sieve Analysis I Hydrometer Analysis Liquid & Plastic Limits Pulk & Dry Density

Consolidation Test

Unconfined Compression Test Sulphate Content of Soil


i
. Chloride Content of Soil 1 * Organic Matter Content of Soil
Complete water analysis of water samples including TDS, Cl, S04 & PH
----------------------------------------------------J L .
I Application o f h i g h range water reducing nd set retarding Concrete admixture in t

mpratures hot weathers, from approved manufacturer conforming to standards mentioned

in the specs,only after the approval of the Engineer.

Application of compatible curing compound from approved manufacturer conforming to

standards mentioned in the specs.only after the aproval of the Engineer.

SECTION -E SIGN BOARD

Providing & Fixing sign board of size 3'x.4' complete in all respect as shown on

drawings and as approved by the Engineer SECTION - F

DISMANTLING AND DE WORKS Ref. Spec. No. 0150

Dismantling & removal of existing material from sub & super structure of demolished /

destructed buildings, if required, and its safe disposal, at appropriate locations, all as

approved by the Engineer.


.1 ____________________________________________________
Kill & backfill v/ith approved selected
material obtained from material excavated
from Project Site, including hauling up to
any lead and lift, placing in layeis and
compaction, etc as approved by the
Engineer
Mild Steel Deformed round bars Grade 40.
Providing and laying 4" thick Class E Nominal Mix (1:4:8) concrete in boundary wall
foundations, as approved by the Engineer
First Class burnt brick masonry in 1:4 cement sand mortar, comprising 9" and above thick
walls and above foundation, complete in all respects.
% thick 1:4 cement sand plaster on boundary wall etc.
Deep struck pointing with 1:3 cement sand mortar
3 coats of weather shield paint or approved equivalent on boundary wall etc. in approved
color by the Engineer, complete in all respects
Providing and Laying 2" thick Damp Proof Course of cement concrete 1:2:4.
0 Providing and fixing in position steel Gate including fabrication, Red Oxide paint, 2
. coats of enamel paint, 12" length sliding bolts on both sides complete in all respects as
per design shown on drawings, only if directed by the Engineer
SECTION-D ADMIXTURE Ref. Spec. No. 2300
1 Application of Antifreeze Concrete admixture at below freezing tempratures, from
approved manufacturer conforming to standards mentioned in the specs,only after the
approval of the Engineer,
' Application of high range water reducing
and hardening accelarator Concrete admixture in cold weathers, from approved*
manufacturer conforming to standards mentioned in the specs,only after the approval of
the Engineer.

& it %^
SECTION-A
RETAINING WALLS
Ref, Spec. No. 1100, 2100, 4300, 6521
Trench excavation in all kinds of materials including rock and compacted backfillwifh suitable
excavated materials complete in all respect, as approved by the Engineer
Providing and laying 3" thick Class E Nominal Mix (1:4:8) concrete in retaining wall foundations,
as approved by the Engineer
1
Providing and laying Random Rubble stone masonary in 1:4 cement sand mortar with
staggered weep holes of 6"x6" size at S apart both horizontally and vertically, as approved by the
Engineer.
Providing and laying 3" thick PCC Ciass C Nominal Mix (1:2:4) coping on top of retaining wall.
Providing and laying 6" thick class "C' Nominal Mix (1:2:4) concrete Band at every 4' height as
shown on drawings.
SECTION - B WALKWAY
Ref. Spec. No. 1100, 4300, 6521,6531
Walkways of 4' width using stone pebbles and dressed stones with 1:4 cement sand mortar over
compacted earth with crevices filled in with stone pebbles, as shown on drawings, complete in all
respect, at locations specified/approved by the Engineer p
SECTION - C
BOUNDARY WALL & MAIN ENTRY GATE. Ref. Spec. No. 4200, 2100. 2300, 6521
Trench excavation in all kinds of-materials including rock and compacted backfillwith suitable
excavated materials complete in all respect, as approved by the Engineer ct
SECTION - G ____________________________

MISCELLANEOUS ITEMS
Tangly, installation, testing & commissioning

of 55 inch (1400mm) dia Ceiling fan. The 56 " c!:a ceiling fan shall be suitable to give an air

displacement of minimum 11700 Cu. ft./ min. me ceiling fan shall comprise circular fan body

metallic fan blades, down rod of suitable dia & length, AC capacitor, internal wiring, terminals all

installation & operational accessories as per fencer specifications, as per site requirements and

as directed by the Engineer


Ceiling hook properly installed in the slab, as
r
directed by the Engineer.

Supply, installation, testing & commissioning of 9 inch (300mm) dia exhaust fan The 9"

, exhaust fan shall be suitable to give an air displacement of minimum 875 Cu.ft./min. The

exhaust fan shall comprise plastic fan blades,


r square plastic body with circular fan opening,
i all installation & operational accessories as per
**
i: tender specifications, as per site requirements V: and as directed by the Engineer. The exhaust
fan shall be suitable for installation in glazing/ i"' glass of windows or ventillators as required.
lECHON-E I T Cables
G sq mm , 2 core PVC/PVC standard copper
conductor cable, 300/500v grade in already installed
conduit.
f. sqmm, 2 core PVC/PVC stranded copper conductor cable, 300/500 V grade in already installed
conduit /on cable tray.
4 so mm , 2 core PVC/PVC standard copper
conductor cable, 300/500v grade in already installed conduit.
SECTION - F
FARTHING
i nr i i i i i m i w j i TTT i i ~n i m ~ ~ wnnr r~i ~rrr~ ~i i ' T
10 sqmm, 1 core PVC insulated stranded copper conductor cable, 450/ 750V grade
in already installed PVC conduits.
6 sqmm, 1 core GREEN PVC insulated stranded copper conductor cable, 450/750V grade in
already installed PVC conduits.
Earth electrode for the earthing of LT
electrical system . The Earth
electrode shall comprise 600 x 600 x 3mm
Thick Copper plate with Four nos. 1/2 inch di? copper nuts, bolts and washers, 3/0SWG HDHC
Copper wire as earthing leads, TWO inch dia Gl pipe (15 feet long), lime and charcoal (Ratio 1:3),
inspection chamber (CC 1:4:8). light duty Cl cover, excavation & backfilling, all accessories as
per site requirements & as directed by the Engineer, complete A pit of dimensions 4 feet x 4 feet
& 15feet deep shall be excavated in the ground. The !ime and charcoal shall be mixed throughly
in the ratio of 1:3 with ONE foot thick hard packed bed in pit. The Copper plate with earthing
leads shall be placed vertically above the lime and charcoal bed.
The 2nos. 3/OSWG Earthing leads shall be connected diagonally to the nuts and bolts on the
copperplate, brought out through the Gl pipe upto the first earth connecting.
SECTION - C _______________________________________
WRING IN CONCEALED CONDUITS
Wning of light circuit from Distribution Board
to light point or fan point, including circuit
wirng between switches on the same circuit wun i riree nos. single core oqmrri rvu
insulated 600/1000 Volts grade solid/stranded
copper conductor cables in concealed PVC
conduits ( conduits partly shared ) including
PVC conduit, conduit accessories etc.
Wiring from switch to light or fan point with 3 nos. single core 1.5 Sqmm PVC insulated 600/1000
Volts grade solid or stranded copper
conductor cables in concealed PVC conduit including PVC conduit, Conduit accessories, etc.
complete. ( conduit partly shared )
Wiriig of circuit from Distribution Board to 5A, 230Volts, 2&3 pin switched socket outlet with 3
nos. one core 2.5 Sqmm PVC insulated 600/1000 Volts grade solid or stranded copper conductor
cables in concealed PVC conduit " including PVC conduit, Conduit accessories, etc. complete. (
conduit partly shared )
Wring from 5Amps, 2&3 pin socket to socket witn 3 nos. one core 2.5 Sqmm PVC insulated
600/1000 Volts grade solid or stranded copper
conductor cables in concealed PVC conduit < including PVC conduit, Conduit accessories, etc
complete. ( conduit partly shared )
SECTION - D _________________________________________________
WIRING ACCESSORIES
10 Anp, 250 Volts, 1 gang 1 way switches, inducing appropriate size concealed back box.
10 Amp, 250 Volts, 2 gang 1 way switches including appropriate size concealed back box
10 Amp, 250 Volts, 3 gang 1 way switches including appropriate size concealed back bo>
5Anps, 250Volts, 2&3 pin switch socket unit induding appropriate size back box.

Fan Dimmer with switch/back box along with wiring accessories.


pD 4+ORDS
5B-GF
NCOMING
)1 40 Amps DP MCB RC-10KA. )1 - 2 Amps Protection fuses 01- Phase Indication Lamp
OUTGOING
04-10 Amps SP MCB RC-10KA 01-20 Amps DP MCB RC-10KA
DB-FF
INCOMING
0 1 - 2 0 Amps DP MCB RC-10kA,
1 - 2 Amps Protection fuses 01- Phase Indication Lamp OUTGOING
04-10 Amps SP MCB RC-10KA
,I
SECTION - B LIGHT FIXTURES
Supply, installation, testing & commissioning of the following types of light fixtures including
electronic ballast .Color 84 TL lamp,internal wiring complete with all mounting accessories as per
architectural arrangements/requiremenls. as acceptibly supplied and installed and as .approved
by the Engineer.
1x36 watt flourescent light complete with lamp philips type TMS-015/136 or equivalent.
2x36 watt flourescent light fixture complete with lamp philips type T.MS-015/236 or equivalent.
t
. =1x36 watt flourescent light fixture complete with lamp . philips type TMS-015/136 with GDL
Reflector or equivalent.
,'.'4x18 Watt flourescent lighting fixture complete with lamp Philips type TBS-300/418 or
equivalent.
.1x18 watt flourescent light complete with lamp philips
. ' type TMS-015/118 or equivalent.
Ix25 Watts Philips made DecoTwist complete with energy saver or equivalent.
tr PiSTRiBirmjvi^RniA pp
IVlain Dintrjhutnion board designated MDB and distribution boards (DB) shall bo made from 16
SWG filioet stool, I ho DB shall be designed, fabricated & manufactured recessed type,The sheet
metal work shall bo cloaned down to bare shining melal degreased, derusted &. painted with
TWO base coats of pntirust RED paint.
The sheet metal work shall be finished in TWO coats of powder paint. The color and shade shall
be as approved by the Engineer. The distribution Board shall be complete with all internal wiring,
tags, identification labels, SPN & E copper busbars, accessories etc.
DB should be provided with the armored glands.
The insulation shall be heat shrinkable type or as directed by the Engineer.
DB 4+OPS _________________________ ___ ____________________________
DB GF
INCOMING___________________________________________________ " _______
C1 No. 40 Amps DP MCB RC-10KA
01 No. 2 Amp fuse
01 No. Phase Indication Lamp.
OUTGOINGS
1 No. 20 Amps DP MCB RC-10KA
03 No. 6 Amps SP MCB RC-10kA (01 Spare)
2 Nos.10 Amps SP MCB RC-10kA (01 Spare)
DB FF '
INCOMING "
01 No.20 Amps DP MCB RC-10kA 01 No. 2 Amp fuse
1 No. Indication Lamp.
OUTGOINGS
3 No. 6 Amps SP MCB RC-10KA.
2 Nos.10 Amps SP MCB RC-10KA (01 Spare)
Providing arid placing deformed {*>| reinforcement (grade 40) of various sizes/diameters with and
including the coni of transportation, loading, unloading, cubing, straightening, bending, binding,
wastage and overlapping, placing in position by concrete spacer blocks or MS chair, tying with
binding wires, cost of chairs and wires etc. in all kinds of RCC works complete in all respects as
shown on drawings and as directed.

Providing and laying stone masonry in 1:6 c/s mortar as shown on drawing and as directed.

Providing and laying dry stone masonary' with partially open joints but adequately inter-lockec! at

places as shown on drawing and as directed.


OPEN DRAIN
Constuction of 1'x1' open drain in P.C.C class C(nominal mix ratio 1:2:4) laid to line &

grade/slope,complete in all respects includ;ng excavation,backfill,MS grating,etc as shown on

drawings and approved by the Engineer.


MISCELLANEOUS Ref. Spec. No. 5150
Supply and installation of centrifugal pump(30gpm discharge, 50ft head,2HP motor) with gale valves
at inlet* & outlet and electrical connections,
*
completed in all respects as approved by ste engineer
Dry chemical powder fire extinguisher 6kg capac ty stored pressure type as per specifications.

SOAKAGE WELL/PIT Ref. Spec. No.5227

Structural excavation in all kinds of soil / materia wet or dry including gravels, conglomerate etc. anc

including timbering & bracing if required, and disposal of surplus excavated material at approved designated

locations, - as directed, by the site incharge.

Providing, placing, compacting, finishing and curing PCC class C (nominal mix ratio 1.2:4) using ordinary

portland cement complete in all respects as per specs, drawings.

Providing, placing, compacting, finishing and curing RCC class B(nomina) mix ratio 1:1.5:3) using

ordinary portland cement, in walls, slabs etc. complete in all respects as per specs, drawings and as

directed.

Providing & placing course gravel or crushed stones inside the well and annular space around the

well complete in all respects as per specs, drawings.

Providing, applying, finishing and curino 1.4 cement sand plaster using ordinary poniard cement on internal

surface- Si above top slab,

complete in all respects as per specs, drawincs and as directed.


Applying two (2) coats of hot bitumen @ 0.2 ib/sft each coat of 10/20 grade to concrete surfaces in contact

with earth.

Providing and placing deformed steel reinforcement (grade 40) of various sizes/diameters with and including

the cost of transportation, loading, unloading, cutting, straightening, bending, binding, wastage and

overlapping, placing in position by concrete spacer blocks or MS chair, tying with binding wires, cost cf

chairs and wires etc. in all kinds of RCC works complete in all respects as shown on drawings and as

directed.

Supply and installation of miscellaneous items of septic tank including 2 No. C.l. cover with frames

(grade C, light duty), 2 diameter u-turned G.l. vent pipes, tees, etc. complete in all respects as shown on

drawings and as directed.

SEPTIC TANK Ref. Spec. No. 5226

Structural excavation in all kinds of soil / material wet or dry including gravels, conglomerate etc. and

including timbering & bracing if required, and disposal of surplus excavated material at approved designated

locations.

Filling and backfilling with selected soil obtained from excavation including lead and lift, watering,compaction

and dressing to required levels and shapes as directed.


Providing, placing, compacting, finishing and
curing PCC class E(nominal mix ratio 1:4:8) usmg
ordinary portland cement complete in all respects
as per specs., drawings & as directed.

Providing, placing, compacting, finishing and curing RCC class B(nominal mix ratio 1:1.5:3) using ordinary

portland cement, in walls, slabs etc. complete in all respects as per specs, drawings and as directed. _
supply and installation of G.l. water^'ii ------------------------------------------------------------------------------------------ -----

conforming to BS-1387 (1985), Medium Grade ,.r all fittings, wrapmg best quality (No. 1) polythene ' tape,

making holes in concrete or masonry and then repairing holes, supports and hangers etc cf the following

diameters, complete in all respects.


(a) 3 inches
(b) 2 inches

Bronze Gate valves, conforming to BS-1952 standards,& shall be of 16-bars for working pressure,open &
shut indicators shall be marked on the handie.the ends may be screwed or flanged,including unions &

jointing arrangement with pipe on both ends of valves; nuts, bolts etc. complete in all respects.
(a) 1 inch

Float valves (automatic) of copper alloy, piston type conforming to B.S 1212. Float shall be of copper

confroming to B.S 1968 including unions & join mg arrangement with pipe on both ends o vav nuts, bolts etc.

complete in all respects .


(a) 2 inch

C.P water tap including all fittings for ^omplet installation.


MANHOLES
Ref. Spec. No. 5230, 5400

Construction of brick masonry manholes inn all items and works as shown on drawing cover and O.l. frame

complete in all resrect-Z directed by the Engineer of following depths"


defined in specifications and as directed bythe Engineer. ye

24"X 24" (grade C light duty) bitumen coated cast iron cover with frame(BS-497) on manholes including all

fittings for complete installation.

RAIN WATER HARVESTING Ref. Specs 5100

Supply, installation, testing and commissioning of horizontal/vertical plastic body double insulated wall type

water tanks of following capacity including all fittings necessary for complete installation.
(a) 500 Gallons for RWH
(b) 75 Gallons for FIRST FLUSH DIVERTER

uPVC rain water pipes conforming to ISO:3633 type "B" of the following diameters, including imported

rubber ring/solvent cement fiitings, jointing, cutting, etc. and then making it good cleaning and testing

etc.complete in all respects.


(a) 4 inches ' gycAVATION FOR TRENCHING
f * .* * - 1 ~ ' Ml .1 I ' . , - - - -|
AND BACKFILLING

RefTspec. 1100

Excavation in all kinds of soil for pipe trenches as per specifications and drawing, including disposal of

surplus excavated material at designated locations.

Filling and backfilling in pipe trenches, with selected soil obtained from excavation including watering and

compaction iri 150mm (6") thick layer and dressing to required shapes.

Supplying, stacking, filling and compacting M trenches, sand bedding material for pips ^ per
drawings.
VALVES
Ref. Specs. 5220

Bionze Gate valves, conforming to BS-1952 standards,& shall be of 16-bars for workirg pressure,open &

shut indicatiors shall be marked on the handle,the ends may be screwed or flanged,including unions &

jointing arrangement with pipe on both ends of valves; nuts, bolts etc. complete in all respects.
(a) 1.25 inch
(b) 1.5 inch

.(c) 1 inch (d) 2 inch

Float valves (automatic) of copper alloy,piston type and shall conform to B.S 1212. Float shall be cf copper

and shall confrom to B.S 1968 including unions & jointing arrangement with pipe on both ends of valves;

nuts, bolts etc. complete in all


respects.
r\
(a) 1.5 inch

upvc Floor I rap (110x75mm) of approved mite with minimum water seal of 40mm including strainer;

making connections; breaking concrete or masonry work & then making it good; etc.

Cawal on vent pipes of the following diameter.

3 inches

Providing, fabricating & fitting uPVC floor Cleanout

of the following diameter, including 2 No *5 elbows,brass rounded threaded cover,adjustable brass

top,short piece cast iron, transition pipe, socket plug, breaking concrete or masonry work & then

making it good, etc. complete in all respects as per drawings & specifications.

f5mm (3")

Construction of Gully Trap Chamber (i2


lear) including supply & fixing of approved make . x . . r\ r'nnctri lotion of 4-1/2

ully trap of uPVC rick masonry in 1 >CC at bottom, 1:2

construction of 4-1/2" thick 4 c/s mortar , 3" thick 1-4.8 4 PCC in benching. (12"x12") r cover with

frame (7 kg). 1/2" thick 1:3 c/s aster on inner face. etc. complete in all isspects

> shown on drawings.


SOU , WASTE. VENTILATING PIPESJ^
FITTINGS Ref. Specs 5100
uPVC Soil, Waste, and vent pipes conforming to ISO:3633 type "B" or BS-4514/5255 class "A" of the

following diameters, including imported miner ring/solvent cement fittings, jointing, cutting, and breaking

concrete/masonry etc. and then making it good, cleaning and testing etc.complete in all respects.

(a) 6 inches

(b) 4 inches

(c) 3 inches

(d) 2 inches

(e) 1-1/2 inches

uPVC Multi Floor Trap (110x75mm),with minimum water seal of 40mm, including strainer; making recpred

number of connections; breaking JCrf e or masonry work & then making it good;

, etc. of approved make. . ^

Supply and installation of Muslim Sho-^- combined with double bib-cock of approved colour inlcluding all

fittings for complete installation. "

WATER SUPPLY PIPES AMP FITTING Ref. Specs 5100

PPR water pipes (cold and hot) Conforming to DIM 8077-78, i/c all fittings, cutting, jointing, making holes in

concrete or masonry etc. ana then repairing holes, supports and hangers etc. of the following diameters.
(a) 1/2 inch i/d (Eq. to PPR 25mm)
(b) 3/4 inch i/d (Eq. to PPR 32mm)
(c) 1 inch i/d (Eq. to PPR 40mm)
(d) 1.25 inch i/d (Eq. to PPR 50 mm)
* (Eq. = Equivalent to; i/d = internal diameter)

Supply and installation of G.l. water pipes conforming to BS-1387 (1985), Medium Grade, i/c all fittings,

wraping best quality (No. 1) teflon tape, making holes in concrete or masonry and then repairing holes,

supports and hangers etc. of the following diameters, complete in all respects.

(a) 1 inch

(b) 1.25 inch

(c) 1.5 inch

Glazed earthenware Laboratory sink,(18"X24") of approved make, colour, size, shape 8< quality including

mixer for cold and hot water, t-stop cocks and all other accessories for complete installation
Supply and fix 5mm thick Glass mirror (24"Z18") , including hard board behind it and all other fittings for

complete installation as per specifications.

Plastic shelf of approved size and shape, with plugs and screws, fixed to concrete, brick stone or wood

work, complete in all respects.

Toilet paper holder (SS) of any shape, pattern arid size, complete with plugs, screws etc., fixed to concrete,

brick, stone or wood work, complete in all respects.

Soap tray of any shape, pattern and size, complete with plugs, screws etc., fixed to concrete, bricx, stone or

wood work, complete in all respects .

CP towel rail:600mm long, 20mm dia conforming to BS 1010, complete with nuts bolts etc.
installation.

C P water tap including all fittings for complete

SANITARY FIXTURES AND FITTINGS Ref. Specs 51 GO

Water closet Asiatic pattern best quality v/ith integral foot rests, P-trap, t-stop cock,waste pipe, 13.5 liters

flushing cistern low down, flush pipe etc, fixed to concrete, brick, stone or wood work, in Light colour.(Orissa

900)

Water closet apparatus European pattern comprising 13.5 liters flushing cistern, seat cover,t- stop

cock,waste pipe etc., (Coupled set in Light colour), any approved size fixed to concrete, brick or stone work,

complete in all respects.

Wash hand basin of approved make, colour, size(24,,X18"), shape & quality including pedestal, bottle trap

with union 1-1/4"basin waste, tee-stop cocks,chromium plated chain and rubber plug.C P. mixer for cold and

hot water, jointing anc! sealing material, painted heavy duty brackets/fixers etc. with all accessories for

complete installation.

Glazed earthenware Laboratory sink,(18"X24") of approved make, colour, size, shape & quality including

mixer for cold and hot water, t-stop cocks and all other accessories for complete installation

Providing & placing 150 micron thick polythene sheet over partiton walls after application of bitumen

coating, as directed by the Engineer

Applying 3/4" thick 1:4 smooth finished cement sand plaster over 1/2" thick 1:4 cement sand rough

plaster, including 1-1/2" wide and 3/4" thick 1:3 cement sand border and 4" wide wooden tray for
blackboards, with black Japan Paint complete in all respect and as directed by the Engineer.

Ladder Rungs (Size 9"x7 -3/4")

Steel Cover opening (Size 2'x2')

Water Stopper PVC ________________________

3 coats of plastic emulsion paint on internal walls upto 5 height of approved quality & color,

including surface preparation by provision of a film with alkali resisting primer on internal plastered

walls to form smooth base , including dusting, rubbing with pumice stone, sand papering, filling, as

per instructions of the manufacturer, complete in all respects and as approved by the Engineer.

3 coats of vinyl emulsion paint of approved quality & color including surface preparation by

provision of a film with alkali resisting primer on internal plastered walls, and ceilings above 5'

height to form smooth base, including dusting, rubbing with pumic stone, sand papering, filling, as

per instructions of the manufacturer, complete in all respects and as approved by the Engineer.

3 coats of weather shield paint or approved equivalent on exterior walls, columns, beams, lintel, etc.

in approved color by the Engineer, complete in all respects.

SECTION - L MISCELLANEOUS

Applying 2 coats of hot bitumen of 10/20 Grade @ 0.2 Ib/sft/coat along structural concrete in contact

with earth and as directed by the Engineer.

Provide & Lay damp proof course, complete in all respects as per specification and shown on

drawings, in following.

a) Horizontal DPC in external walls

b) Horizontal DPC in internal walls

c) Vertical DPC in external walls


SECTION - J
FLOOR & WALL F1NISHFS Ref. Spec. No. 6600
Providing and laying 2" and down gauge graded crushed stone ballast as hard core under floors, steps,
plinth protection, etc. complete in all respects.
Providing and laying 2" thick Class "C" nominal mix (1:2:4) concrete in ramps complete in all respects.
Providing and laying -V
'[i' thick Class "D" nominal mix (1:3:6) concrete in plinth protection, laid in panels as
shown on drawings with 1-!4" deep and 5mm thick . glass divider strips etc. complete in all respects.
Providing and laying class "E" nominal mix (1:4:8) concrete iaid under floors, plinth , protection, planter
steps & ramps etc. complete in all respects as shown on drawings.
Providing and laying 2" thick Class "C" nominal mix (1:2:4) concrete laid in panels including 1-/4" deep and
5mm thick glass divider strips with smooth top finish etc. complete in all respects.
Vi' thick 1:4 cement sand skirting of 4" height over Vi'thick 1:4 cement sand rough base plaster.

SECTION - I FALSE CEILING

Providing and Fixing 3/8" thick 2x2' PVC Laminated Gypsum board ceiling with back side aluminum

foil, including framing, hanging supports, screws, aluminum tees etc. complete in all respects, as

shown on the drawings and as approved by the Engineer


i IUN - H
!IB^IURALSIEEU^
Kef. Spec. No. 3000, 4400
Hand railing, comprising mild <4PPI Pipe balusters, mild steel
cuttim' m'h Sri-el SqUare P'pe micldle rails69. bending, welding, grindina
pain ng/polishing, embedding in wall
floor/steps/ramps complete as shown on
drawings and as approved by the Engineer
Providing, Fabricating, Cutting, Erecting, end fitting/fixing of steel Trusses, including gusset plates, base
plates, bolts, nuts, limpets, washers, red oxide and matt enamel painting etc. as shown on drawings
complete in all respects. IV
Supplying and fitting 22 SWG Pre Painted (Color approved by the Engineer) PG1 sheet in ridging
including overlaps, ridging, riveting, limpets, washers, Gl Bolts, nuts etc. over truss as shown on drawings,
complete in all respects.
Supplying and fitting 22 SWG Pre Painted (Color approved by the Engineer) PG1 sheet including
overlaps, riveting, limpets, washers, Gl Bolts, nuts etc for projection of ceiling, scuppers - drains complete
in all respects, as shown on the drawings or as directed by the Engineer.

Supplying and fitting 24 SWG Pre Painted (Color approved by the Engineer) Gl sheet (Not Plain) roofing

including overlaps, limpets, washers, Bolts, nuts etc complete in all respects as directed by the Engineer

First Aid cabinet ( 2,x2'x9" ) with 3/4" thick imported laminated MDF board, includ'rng locks &

catchers, handle, hanging arrangement etc. as per design shown on drawings complete in all

respects.

Providing & Fixing RCC slab Almirahs with

a) 2' width
SECTION - G

CARPENTRY AND JOINERY Ref. Spec. No. 3000, 4G00, 6700

Providing and fixing in position steel doors as per design shown on drawings compromising M.S. Box

section frame, MDF (imported and water proof) panels, 5 mm thick plain glass including rubber gaskets,

screws, synthetic enamel paint and red oxide paint on steel sections and matt enamel paint on MDF wood

panels, hold fasts, cutting, welding and Class 'C' concrete in hold fasts, all hardware fittings including door

locks, tower bolts, handles etc. complete in all respects.

a) D2

b) D3

c) D4

Steel windows comprising MS frame and MS shutter with 5mm thick local plain glass ' and/or fixed fly

screen in openable panels, as per design shown on drawings including locking arrangement,grills and all

hardware fittings as per schedule, painting with red- oxide and matt enamel paint, complete in aii respects.
V it

' a) W1 b) W2

SECTION - F CEMENT PLASTER

Ref. Spec. No. 6521

3/4" thick 1:4 cement sand plaster on interior walls, columns, beams, slabs, stair cases etc. at

ground floor and first floor

14" thick 1:4 cement sand plaster on exterior

columns, beams, walls etc at Ground Floor. 14" thick 1:4 cement sand plaster on exterior

columns, beams, walls etc at First Floor.

14" thick 1:3 cement sand plaster on steps etc.

Deep struck pointing with 1:2 cement sand mortar at Ground Floor.

Deep struck pointing with 1:2 cement sand mortar at First Floor

SECTION - E

BRICK MASONRY WORK Ref. Spec. No. 4100

First Class burnt brick masonry in 1:4 cement sand mortar, comprising 9" and above thick walls in
foundations, complete in all respects.

First Class burnt brick masonry in 1:4 cement sand mortar, comprising 9" and above thick walls in

Ground Floor, complete in all respects.

First Class burnt brick masonry in 1:4 cement sand mortar, comprising 9" and above thick walls in

First Floor, complete in all respects.

4y2" thick brick masonry in 1:4 cement sand mortar in Ground Floor complete in all respects.

Providing and laying Reinforced Concrete Class "B" (nominal mix ratio 1:1.5;3) in foundations.

Providing and laying Reinforced Concrete Class "B" (nominal mix ratio 1:1.5:3) in the

following:
i

a) Column, Column stems in foundations and Ground Floor.

b)
*
Columns at First Floor

c) Plinth Beam

cS) Roof/Anchor Beams, Lintels etc. at Gound Floor

e) Roof/Anchor Beams, Lintels etc. at First Floor.

f) Slabs, Stair Case, Landing etc.

g) Shear wall etc.

h) RCC wall etc.

SECTION - Fi

TFgflgjTE CONTROL TREATMENT Rot. Spec. No. 1600

Termite control treatment as approved bv the Engineer

SECTION - C REINFORCEMENT Ref. Spec. No. 2200

Mild Steel Deformed round bars Grade 40. SECTION - D

PLAIN AMD REINFORCED CONCRETE Raf. Spec. Mo. 2100, 2300

Providing and laying Plain Cement Concrete Class "E" (nominal mix ratio 1:4:8) in foundation, under walls,

steps etc.
SECTION - A EARTHWORKS Ref. Spec. No. 1100

Excavation in all kinds of soil including rock, disposal of unsuitable material outside the Project limits upto

any lead and stacking of suitable material as designated/approved by the Engineer.

Fill & backfill with approved selected material obtained from material excavated from Project Site,

including hauling up to any lead and lift, placing in layers and compaction, etc. as approved by the Engineer

Fill with approved selected material obtained from outside source, including hauling up tc any lead and lift,

placing in layers ano compaction, etc. as approved by the Engineer