Professional Documents
Culture Documents
Reaction order
CHEM4005-Ahmed J. Ali/2009 1
Library Reaction
Components
When a Library Equilibrium Reaction is selected, all of its constituent components are
automatically added to the Reaction Manager. You can then use the components in the Rxn
Components group of the Reaction Manager to define other reactions. Library reactions
can be installed prior to the addition of components to the case. You are not required to add
components using the Component List property view or Reaction Manager.
To add a Library reaction, do the following:
1. From the Reaction Manager, click the Add Rxn button in the Reactions group.
2. Highlight Equilibrium from the Reactions property view and click the Add Reaction
button.
3. Move to the Library tab of the Equilibrium Reaction property view and select a
reaction from the Library Equilibrium Rxns group.
4. Click the Add Library Rxn button. All library information concerning the reaction is
transferred to the various tabs of the Equilibrium Reaction property view. The components
used by the reaction are now shown in the Rxn Components group of the Reaction 3
Manager.
Reactions in HYSYS
Conversion
Equilibrium
Hetrogeneous
Kinetic
Simple rate
CHEM4005-Ahmed J. Ali/2009 2
Reactions in HYSYS
Conversion Reaction/
Stoichiometry Tab
CHEM4005-Ahmed J. Ali/2009 3
Conversion Reaction/ Basis Tab
Conversion Reaction/
Basis Tab
CHEM4005-Ahmed J. Ali/2009 4
Equilibrium Reaction
The Equilibrium Reaction computes the conversion for any number of
simultaneous or sequential reactions with the reaction equilibrium
parameters and stoichiometric constants you provide.
The Equilibrium constant can be expressed as follows:
Equilibrium Reaction
10
CHEM4005-Ahmed J. Ali/2009 5
Equilibrium Reaction/Basis Tab
The Keq Source group contains four radio buttons and a checkbox.
By selecting the appropriate radio button, you can select one of four options as
the Keq Source for the equilibrium reaction.
If the Auto Detect checkbox is selected, Aspen HYSYS automatically changes
the Keq Source, depending on the Keq information you provide. For example, if you
enter a fixed equilibrium constant, the Fixed Keq radio button is automatically
selected. If you later add data to the Table tab, the Keq vs. T Table radio button is 11
automatically selected.
12
CHEM4005-Ahmed J. Ali/2009 6
Equilibrium Reaction / Keq Tab
13
Equilibrium Reaction/Approach
Under certain process conditions, an equilibrium reaction may not, actually reach equilibrium. The
Equilibrium reaction set uses two types of approach, Fractional and Temperature, to simulate this
type of situation. You may select either one or both types of approaches for use in the simulation.
14
CHEM4005-Ahmed J. Ali/2009 7
Equilibrium Reaction/Approach
15
Equilibrium Reaction/
Library Tab
The Library tab allows you to add pre-defined reactions from the Aspen HYSYS
Library. The components for the selected Library reaction are automatically
transferred to the Rxn Components group of the Reaction Manager.
When you select a reaction, all data for the reaction, including the stoichiometry,
basis, and Ln(K) parameters, are transferred into the appropriate location on the
Equilibrium Reaction property view. To access a library reaction, highlight it from
the Library Equilibrium Rxns group and click the Add Library Rxn button.
16
CHEM4005-Ahmed J. Ali/2009 8
Kinetic Reaction
To define a Kinetic Reaction, it is necessary to specify the forward Arrhenius Parameters
(the reverse is optional), the stoichiometric coefficients for each component, and the
forward (and reverse) reaction orders. An iterative calculation occurs, that requires the
Solver to make initial estimates of the outlet compositions. With these estimates, the rate of
reaction is determined. A mole balance is then performed as a check on the rate of reaction.
If convergence is not attained, new estimates are made and the next iteration is executed.
17
18
CHEM4005-Ahmed J. Ali/2009 9
Kinetic Reaction/Stoichiometry Tab/
Thermodynamic Consistency
19
20
CHEM4005-Ahmed J. Ali/2009 10
Kinetic Reaction/Stoichiometry Tab/
Thermodynamic Consistency
21
Stoichometery
22
CHEM4005-Ahmed J. Ali/2009 11
Kinetic Reaction/Basis Tab
23
24
CHEM4005-Ahmed J. Ali/2009 12
Kinetic Reaction/Parameters Tab
25
26
CHEM4005-Ahmed J. Ali/2009 13
Kinetic Reaction/Parameters Tab
27
28
CHEM4005-Ahmed J. Ali/2009 14
Simple Rate Reaction/Stoichiometry Tab
29
30
CHEM4005-Ahmed J. Ali/2009 15
Simple Rate Reaction/Parameters Tab
31
32
CHEM4005-Ahmed J. Ali/2009 16
Heterogeneous Catalytic Reaction
Aspen HYSYS provides a heterogeneous catalytic reaction kinetics
model to describe the rate of catalytic reactions involving solid
catalyst. The rate equation is expressed in the general form
according to Yang and Hougen (1950):
33
34
CHEM4005-Ahmed J. Ali/2009 17
Heterogeneous Catalytic Reaction
35
The rate constants kf, kr and Kk are all in Arrhenius form. You are
required to prove the Arrhenius parameters (preexponential factor A
and activation energy E) for each of these constants.
You may have to group constants, for example in Equation (5.16),
kf = k+ KAKB. You must take care in inputting the correct values of
the Arrhenius equation. Also note that no default values are given
for these constants.
The Heterogeneous Catalytic Reaction option can be used in both
CSTR and PFR reactor unit operations. A typical Reaction Set may
include multiple instances of the Heterogeneous Catalytic Reaction.
36
CHEM4005-Ahmed J. Ali/2009 18
Heterogeneous Catalytic Reaction/Stoichiometry
37
38
CHEM4005-Ahmed J. Ali/2009 19
Heterogeneous Catalytic Reaction/BASIS
39
40
CHEM4005-Ahmed J. Ali/2009 20
Heterogeneous Catalytic Reaction/
Numerator Tab
The Numerator tab is specified in much the same way as
you would specify a typical Aspen HYSYS Kinetic
Reaction. The Numerator tab is shown below:
41
CHEM4005-Ahmed J. Ali/2009 21
Heterogeneous Catalytic Reaction/
Denominator Tab
43
44
CHEM4005-Ahmed J. Ali/2009 22
Summary of Reactions in HYSYS
45
Reaction Sets
All Reaction Sets created within the Reaction Manager become available
for attachment to your reactor operations in the flowsheet. Reaction Sets
may contain more than one reaction. There is limited flexibility for the
mixing of reaction types within a Reaction Set. You can have Equilibrium
and Kinetic reactions within a single Reaction Set, but you must have a
distinct Reaction Set for conversion reactions.
Aspen HYSYS provides the Global Rxn Set, which contains all
compatible reactions that you have defined in the case. If you only add
Kinetic and Equilibrium reactions, or exclusively Conversion reactions to
the case, all reactions are active within the Global Rxn Set. However, if
you add an incompatible mix of reactions (i.e., Conversion and Kinetic),
only the type of reactions that are compatible with the first installed
reaction are active in the Global Rxn Set.
The same reaction can be active in multiple reaction sets. A new set can be 46
added from the Reaction Manager by selecting the Add Set button.
CHEM4005-Ahmed J. Ali/2009 23
Types of reactors in HYSYS
48
CHEM4005-Ahmed J. Ali/2009 24
CSTR/General
The CSTR is a vessel in which Kinetic, Heterogeneous Catalytic, and Simple Rate
reactions can be performed
49
Parameters Page
50
CHEM4005-Ahmed J. Ali/2009 25
Parameters Page
51
Parameters Page
52
CHEM4005-Ahmed J. Ali/2009 26
Parameters Page
53
Parameters Page
54
CHEM4005-Ahmed J. Ali/2009 27
Reactions Tab
55
Reactions Tab
Reaction Extents Radio Button
56
CHEM4005-Ahmed J. Ali/2009 28
Reactions Tab
Reaction Balance Radio Button
57
Reactions Tab
Stoichiometry Radio Button
58
CHEM4005-Ahmed J. Ali/2009 29
Reactions Tab
Basis Radio Button
You can view the properties for a specific reaction by selecting the
reaction from the Reaction drop-down list, and its data appears in
the Basis group.
Changes can be made to the reaction rate parameters (frequency
factor, A, activation energy, E, and ), but these changes are
reflected only in the active reactor. The changes do not affect the
global reaction.
To return the global reaction values, select the appropriate Use
Default checkbox. For instance, if you have made a change to the
forward reaction activation energy (E), the Use Default E checkbox 59
is inactive. Select this checkbox to return to the global E value.
Rating Tab
60
CHEM4005-Ahmed J. Ali/2009 30
Rating Tab
61
Rating
Tab
62
CHEM4005-Ahmed J. Ali/2009 31
Rating Tab
63
Rating Tab
64
CHEM4005-Ahmed J. Ali/2009 32
Plug Flow Reactor
The Plug Flow Reactor (PFR), also known as the Tubular Reactor, generally
consists of a bank of cylindrical pipes or tubes. The flow field is modeled as plug
flow, implying that the stream is radially isotropic (without mass or energy
gradients). This also implies that axial mixing is negligible.
Newtons Method
The default calculation process for solving the PFR is Newtons method. In this
method, the PFR is divided into segments (subvolumes) that behave like well-
mixed, stirred tank reactors.
For an adiabatic reactor in the solution step, the outer loop converges on enthalpy
and temperature, and the inner loop converges on composition.
To reduce the convergence time to solve the PFR, you can specify the reactor
outlet stream temperature and reactor duty to eliminate the outer loop calculation.
However, to model an adiabatic reactor, you must manually converge on the
outlet stream temperature.
In the inner loop, the program solves the outlet fluid composition for an assumed
.
value of outlet fluid temperature using a Newton strategy
66
CHEM4005-Ahmed J. Ali/2009 33
(PFR) Property View/Design Tab
67
Parameters Page
68
CHEM4005-Ahmed J. Ali/2009 34
Parameters Page/Pressure Drop
Parameters Group
In the Pressure Drop Parameters group, you can select one of the available radio
buttons for the determination of the total pressure drop across the reactor.
69
70
CHEM4005-Ahmed J. Ali/2009 35
Heat Transfer Page
71
72
CHEM4005-Ahmed J. Ali/2009 36
Heat Transfer Page
73
Reactions Tab
74
CHEM4005-Ahmed J. Ali/2009 37
Reactions Tab
75
76
CHEM4005-Ahmed J. Ali/2009 38
Details Page
77
Stoichiometry Group
78
CHEM4005-Ahmed J. Ali/2009 39
Results Page/Basis Group
79
Results Page/
Reaction Extents
80
CHEM4005-Ahmed J. Ali/2009 40
Reaction Balance
81
Sizing Page
82
CHEM4005-Ahmed J. Ali/2009 41
Tube Dimensions
83
Tube Packing
84
CHEM4005-Ahmed J. Ali/2009 42
Performance Tab
85
Conditions Page
86
CHEM4005-Ahmed J. Ali/2009 43
CSTR Example
K K0 exp E
RT
rA kCA
UNIQUAC
CHEM4005-Ahmed J. Ali/2009 44
CHEM4005-Ahmed J. Ali/2009 45
CHEM4005-Ahmed J. Ali/2009 46
First order reaction
based on
propylene oxide
CHEM4005-Ahmed J. Ali/2009 47
K K0 exp E
RT
CHEM4005-Ahmed J. Ali/2009 48
CHEM4005-Ahmed J. Ali/2009 49
CHEM4005-Ahmed J. Ali/2009 50
CHEM4005-Ahmed J. Ali/2009 51
CHEM4005-Ahmed J. Ali/2009 52
CHEM4005-Ahmed J. Ali/2009 53
CHEM4005-Ahmed J. Ali/2009 54
CHEM4005-Ahmed J. Ali/2009 55
T@ Product = T@ Out
CHEM4005-Ahmed J. Ali/2009 56
CHEM4005-Ahmed J. Ali/2009 57
Tproduct=(Multiplier)*(Tout)+offset
We want : Tproduct=Tout
CHEM4005-Ahmed J. Ali/2009 58
CHEM4005-Ahmed J. Ali/2009 59