You are on page 1of 59

Aspen-HYSYS Simulation

Reactions and Reactors

Reaction order

When entering the reaction kinetics in the basis


environment, note that, in general, the reaction orders
of the components are NOT the same as their
stoichiometric coefficients.
Use the powers on the basis (concentration, mole
fraction, etc.) for the actual reaction kinetics
specified or taken from the literature. For example if
the rate is proportional to CA0.5 then the basis is
concentration and the order for component A is 0.5
2

CHEM4005-Ahmed J. Ali/2009 1
Library Reaction
Components

When a Library Equilibrium Reaction is selected, all of its constituent components are
automatically added to the Reaction Manager. You can then use the components in the Rxn
Components group of the Reaction Manager to define other reactions. Library reactions
can be installed prior to the addition of components to the case. You are not required to add
components using the Component List property view or Reaction Manager.
To add a Library reaction, do the following:
1. From the Reaction Manager, click the Add Rxn button in the Reactions group.
2. Highlight Equilibrium from the Reactions property view and click the Add Reaction
button.
3. Move to the Library tab of the Equilibrium Reaction property view and select a
reaction from the Library Equilibrium Rxns group.
4. Click the Add Library Rxn button. All library information concerning the reaction is
transferred to the various tabs of the Equilibrium Reaction property view. The components
used by the reaction are now shown in the Rxn Components group of the Reaction 3

Manager.

Reactions in HYSYS

Conversion
Equilibrium
Hetrogeneous
Kinetic
Simple rate

CHEM4005-Ahmed J. Ali/2009 2
Reactions in HYSYS

Conversion Reaction/
Stoichiometry Tab

CHEM4005-Ahmed J. Ali/2009 3
Conversion Reaction/ Basis Tab

Conversion Reaction/
Basis Tab

CHEM4005-Ahmed J. Ali/2009 4
Equilibrium Reaction
The Equilibrium Reaction computes the conversion for any number of
simultaneous or sequential reactions with the reaction equilibrium
parameters and stoichiometric constants you provide.
The Equilibrium constant can be expressed as follows:

Equilibrium Reaction

10

CHEM4005-Ahmed J. Ali/2009 5
Equilibrium Reaction/Basis Tab

The Keq Source group contains four radio buttons and a checkbox.
By selecting the appropriate radio button, you can select one of four options as
the Keq Source for the equilibrium reaction.
If the Auto Detect checkbox is selected, Aspen HYSYS automatically changes
the Keq Source, depending on the Keq information you provide. For example, if you
enter a fixed equilibrium constant, the Fixed Keq radio button is automatically
selected. If you later add data to the Table tab, the Keq vs. T Table radio button is 11

automatically selected.

Equilibrium Reaction / Keq Tab


Depending on which option was selected in the Keq Source group (from the Basis tab), the Keq
tab will display the appropriate information. The following table outlines each of the Keq
source options and the respective information on the Keq tab.

12

CHEM4005-Ahmed J. Ali/2009 6
Equilibrium Reaction / Keq Tab

13

Equilibrium Reaction/Approach
Under certain process conditions, an equilibrium reaction may not, actually reach equilibrium. The
Equilibrium reaction set uses two types of approach, Fractional and Temperature, to simulate this
type of situation. You may select either one or both types of approaches for use in the simulation.

14

CHEM4005-Ahmed J. Ali/2009 7
Equilibrium Reaction/Approach

15

Equilibrium Reaction/
Library Tab

The Library tab allows you to add pre-defined reactions from the Aspen HYSYS
Library. The components for the selected Library reaction are automatically
transferred to the Rxn Components group of the Reaction Manager.

When you select a reaction, all data for the reaction, including the stoichiometry,
basis, and Ln(K) parameters, are transferred into the appropriate location on the
Equilibrium Reaction property view. To access a library reaction, highlight it from
the Library Equilibrium Rxns group and click the Add Library Rxn button.

16

CHEM4005-Ahmed J. Ali/2009 8
Kinetic Reaction
To define a Kinetic Reaction, it is necessary to specify the forward Arrhenius Parameters
(the reverse is optional), the stoichiometric coefficients for each component, and the
forward (and reverse) reaction orders. An iterative calculation occurs, that requires the
Solver to make initial estimates of the outlet compositions. With these estimates, the rate of
reaction is determined. A mole balance is then performed as a check on the rate of reaction.
If convergence is not attained, new estimates are made and the next iteration is executed.

17

Kinetic Reaction/Stoichiometry Tab

18

CHEM4005-Ahmed J. Ali/2009 9
Kinetic Reaction/Stoichiometry Tab/
Thermodynamic Consistency

19

Kinetic Reaction/Stoichiometry Tab/


Thermodynamic Consistency

20

CHEM4005-Ahmed J. Ali/2009 10
Kinetic Reaction/Stoichiometry Tab/
Thermodynamic Consistency

21

Stoichometery

22

CHEM4005-Ahmed J. Ali/2009 11
Kinetic Reaction/Basis Tab

23

Kinetic Reaction/Basis Tab

24

CHEM4005-Ahmed J. Ali/2009 12
Kinetic Reaction/Parameters Tab

25

Kinetic Reaction/Parameters Tab

26

CHEM4005-Ahmed J. Ali/2009 13
Kinetic Reaction/Parameters Tab

27

Simple Rate Reaction


The Simple Rate Reaction is also similar to the Kinetic Reaction,
except that the reverse reaction rate expression is derived from
equilibrium data.

28

CHEM4005-Ahmed J. Ali/2009 14
Simple Rate Reaction/Stoichiometry Tab

29

Simple Rate Reaction/Basis Tab

30

CHEM4005-Ahmed J. Ali/2009 15
Simple Rate Reaction/Parameters Tab

31

Simple Rate Reaction/Parameters Tab

32

CHEM4005-Ahmed J. Ali/2009 16
Heterogeneous Catalytic Reaction
Aspen HYSYS provides a heterogeneous catalytic reaction kinetics
model to describe the rate of catalytic reactions involving solid
catalyst. The rate equation is expressed in the general form
according to Yang and Hougen (1950):

Since these types of reactions involve surface reaction together with


adsorption (and desorption) of reactants and products, the resulting
rate expression will be strongly mechanism dependent.
Consider the following the simple reaction:

33

Heterogeneous Catalytic Reaction

34

CHEM4005-Ahmed J. Ali/2009 17
Heterogeneous Catalytic Reaction

35

Heterogeneous Catalytic Reaction

The rate constants kf, kr and Kk are all in Arrhenius form. You are
required to prove the Arrhenius parameters (preexponential factor A
and activation energy E) for each of these constants.
You may have to group constants, for example in Equation (5.16),
kf = k+ KAKB. You must take care in inputting the correct values of
the Arrhenius equation. Also note that no default values are given
for these constants.
The Heterogeneous Catalytic Reaction option can be used in both
CSTR and PFR reactor unit operations. A typical Reaction Set may
include multiple instances of the Heterogeneous Catalytic Reaction.

36

CHEM4005-Ahmed J. Ali/2009 18
Heterogeneous Catalytic Reaction/Stoichiometry

When the Heterogeneous Catalytic Reaction is selected, the


following property view appears:

37

Heterogeneous Catalytic Reaction

For each catalytic reaction, you must supply the


following information:

38

CHEM4005-Ahmed J. Ali/2009 19
Heterogeneous Catalytic Reaction/BASIS

The Basis tab for a catalytic reaction is shown below:

39

Heterogeneous Catalytic Reaction/BASIS


On the Basis tab, the following parameters may be specified:

40

CHEM4005-Ahmed J. Ali/2009 20
Heterogeneous Catalytic Reaction/
Numerator Tab
The Numerator tab is specified in much the same way as
you would specify a typical Aspen HYSYS Kinetic
Reaction. The Numerator tab is shown below:

41

Heterogeneous Catalytic Reaction/


Numerator Tab
You must supply the forward and reverse parameters of the
extended Arrhenius equation. The forward and reverse reaction rate
constants are calculated from these values. In addition to the rate
constants, you must also specify the reaction order of the various
components for both the forward and reverse reactions. This is done
by selecting the Components field of the Reaction Order cell matrix,
and selecting the appropriate component from the drop-down list
and entering values for the Forward and/or Reverse orders.
When specifying Forward and Reverse relationships it is important
to maintain thermodynamic consistency. For more information on
thermodynamic consistency see Section 5.3.4 - Kinetic Reaction,
Thermodynamic Consistency.
42

CHEM4005-Ahmed J. Ali/2009 21
Heterogeneous Catalytic Reaction/
Denominator Tab

43

Heterogeneous Catalytic Reaction/


Denominator Tab

44

CHEM4005-Ahmed J. Ali/2009 22
Summary of Reactions in HYSYS

45

Reaction Sets
All Reaction Sets created within the Reaction Manager become available
for attachment to your reactor operations in the flowsheet. Reaction Sets
may contain more than one reaction. There is limited flexibility for the
mixing of reaction types within a Reaction Set. You can have Equilibrium
and Kinetic reactions within a single Reaction Set, but you must have a
distinct Reaction Set for conversion reactions.
Aspen HYSYS provides the Global Rxn Set, which contains all
compatible reactions that you have defined in the case. If you only add
Kinetic and Equilibrium reactions, or exclusively Conversion reactions to
the case, all reactions are active within the Global Rxn Set. However, if
you add an incompatible mix of reactions (i.e., Conversion and Kinetic),
only the type of reactions that are compatible with the first installed
reaction are active in the Global Rxn Set.

The same reaction can be active in multiple reaction sets. A new set can be 46

added from the Reaction Manager by selecting the Add Set button.

CHEM4005-Ahmed J. Ali/2009 23
Types of reactors in HYSYS

HYSYS has six types of idealized reactor models


built in:
1. Conversion,
2. Equilibrium,
3. Gibbs,
4. Yield shift,
5. Plug flow, and
6. Continuous stirred tank (CSTR)
47

General Types of reactors in HYSYS

48

CHEM4005-Ahmed J. Ali/2009 24
CSTR/General
The CSTR is a vessel in which Kinetic, Heterogeneous Catalytic, and Simple Rate
reactions can be performed

49

Parameters Page

50

CHEM4005-Ahmed J. Ali/2009 25
Parameters Page

51

Parameters Page

52

CHEM4005-Ahmed J. Ali/2009 26
Parameters Page

53

Parameters Page

54

CHEM4005-Ahmed J. Ali/2009 27
Reactions Tab

55

Reactions Tab
Reaction Extents Radio Button

56

CHEM4005-Ahmed J. Ali/2009 28
Reactions Tab
Reaction Balance Radio Button

57

Reactions Tab
Stoichiometry Radio Button

58

CHEM4005-Ahmed J. Ali/2009 29
Reactions Tab
Basis Radio Button

You can view the properties for a specific reaction by selecting the
reaction from the Reaction drop-down list, and its data appears in
the Basis group.
Changes can be made to the reaction rate parameters (frequency
factor, A, activation energy, E, and ), but these changes are
reflected only in the active reactor. The changes do not affect the
global reaction.
To return the global reaction values, select the appropriate Use
Default checkbox. For instance, if you have made a change to the
forward reaction activation energy (E), the Use Default E checkbox 59
is inactive. Select this checkbox to return to the global E value.

Rating Tab

60

CHEM4005-Ahmed J. Ali/2009 30
Rating Tab

61

Rating
Tab

62

CHEM4005-Ahmed J. Ali/2009 31
Rating Tab

63

Rating Tab

64

CHEM4005-Ahmed J. Ali/2009 32
Plug Flow Reactor
The Plug Flow Reactor (PFR), also known as the Tubular Reactor, generally
consists of a bank of cylindrical pipes or tubes. The flow field is modeled as plug
flow, implying that the stream is radially isotropic (without mass or energy
gradients). This also implies that axial mixing is negligible.

Notice that only Kinetic, Heterogeneous Catalytic, and


Simple Rate reactions are allowed in the PFR.
65

Newtons Method
The default calculation process for solving the PFR is Newtons method. In this
method, the PFR is divided into segments (subvolumes) that behave like well-
mixed, stirred tank reactors.
For an adiabatic reactor in the solution step, the outer loop converges on enthalpy
and temperature, and the inner loop converges on composition.
To reduce the convergence time to solve the PFR, you can specify the reactor
outlet stream temperature and reactor duty to eliminate the outer loop calculation.
However, to model an adiabatic reactor, you must manually converge on the
outlet stream temperature.
In the inner loop, the program solves the outlet fluid composition for an assumed
.
value of outlet fluid temperature using a Newton strategy

66

CHEM4005-Ahmed J. Ali/2009 33
(PFR) Property View/Design Tab

67

Parameters Page

68

CHEM4005-Ahmed J. Ali/2009 34
Parameters Page/Pressure Drop
Parameters Group
In the Pressure Drop Parameters group, you can select one of the available radio
buttons for the determination of the total pressure drop across the reactor.

69

Parameters Page/Duty Parameters

70

CHEM4005-Ahmed J. Ali/2009 35
Heat Transfer Page

71

Heat Transfer Page

72

CHEM4005-Ahmed J. Ali/2009 36
Heat Transfer Page

73

Reactions Tab

74

CHEM4005-Ahmed J. Ali/2009 37
Reactions Tab

75

Catalyst Data Group

76

CHEM4005-Ahmed J. Ali/2009 38
Details Page

77

Stoichiometry Group

78

CHEM4005-Ahmed J. Ali/2009 39
Results Page/Basis Group

79

Results Page/
Reaction Extents

80

CHEM4005-Ahmed J. Ali/2009 40
Reaction Balance

81

Sizing Page

82

CHEM4005-Ahmed J. Ali/2009 41
Tube Dimensions

83

Tube Packing

84

CHEM4005-Ahmed J. Ali/2009 42
Performance Tab

85

Conditions Page

86

CHEM4005-Ahmed J. Ali/2009 43
CSTR Example

Following reaction take place in a process.


Compare performance of the CSTR and PFR for isotherm
reaction condition

C3H6O is base component

K K0 exp E
RT
rA kCA

UNIQUAC

CHEM4005-Ahmed J. Ali/2009 44
CHEM4005-Ahmed J. Ali/2009 45
CHEM4005-Ahmed J. Ali/2009 46
First order reaction
based on
propylene oxide

CHEM4005-Ahmed J. Ali/2009 47
K K0 exp E
RT

CHEM4005-Ahmed J. Ali/2009 48
CHEM4005-Ahmed J. Ali/2009 49
CHEM4005-Ahmed J. Ali/2009 50
CHEM4005-Ahmed J. Ali/2009 51
CHEM4005-Ahmed J. Ali/2009 52
CHEM4005-Ahmed J. Ali/2009 53
CHEM4005-Ahmed J. Ali/2009 54
CHEM4005-Ahmed J. Ali/2009 55
T@ Product = T@ Out

CHEM4005-Ahmed J. Ali/2009 56
CHEM4005-Ahmed J. Ali/2009 57
Tproduct=(Multiplier)*(Tout)+offset

We want : Tproduct=Tout

Multiplier=1 and offset=0

CHEM4005-Ahmed J. Ali/2009 58
CHEM4005-Ahmed J. Ali/2009 59

You might also like