Table of contents

Products
Boiler Oil Gas Chapter 2, page 7
floorstanding Vitorond 100 Vitorond 100
18 to 100 kW Vitorond 111 Vitola 200 1
Vitola 200 Vitola 222
Vitola 222 Vitogas 200-F
Vitoladens 300-T Vitocrossal 300
Vitoladens 300-C

Boiler Oil Gas Chapter 3, page 25


wall mounted Vitoladens 300-W Vitopend 200-W
3.8 to 35 kW Vitoladens 333-F Vitodens 200-W
Vitodens 222-W
Vitodens 222-F
Vitodens 300-W
Vitodens 333-F
Vitodens 343-F

Boiler Oil Gas Chapter 4, page 74


wall mounted Vitodens 200-W
45 to 105 kW

Solid fuel boiler Vitoligno 100-S Chapter 5, page 109


Vitolig 200
Vitoligno 300-P

Multi-mode systems with


Boiler, floorstanding Chapter 5, pages
115, 130, 143, 156
Boiler, wall mounted Chapter 5,
page 122, 134 149
161
Solar thermal systems Vitosol 200-F Chapter 6, page 183
Vitosol 300-F
Vitosol 200-T
Vitosol 300-T

In conjunction with:
Floorstanding boilers Chapter 2, page 7
Wall mounted boilers, 3.8 to 35 kW Chapter 3, page 25
Wall mounted boilers, 45 to 105 kW Chapter 4, page 74
Solid fuel boilers Chapter 5, page 109
5822 470 GB

System examples VIESMANN 5


Table of contents (cont.)

Numbering of the technical components and the electrical connections

1
qE eE rR
2/52M1 M 2/52M2 M
2/21

20M1
qE
2/21

21
28
50
2/28 2
qW
2/1

2M1
40

145
20M2,24

1
5
3

8
(5Sol)
20M1
52M1
52M2

(6)
21
28
50

X2 4
2/5
qQ 2
qR
2M1
2M2

2/5Sol
40

145
20M2,24

1
5

26/S2
2/5 9
qQ 1

5822 470 GB

6 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW

2.1 Overview of sample applications


One heating circuit without mixer or DHW heating (optional solar DHW One heating circuit without mixer, one heating circuit with mixer and
heating) DHW heating
See page 8 See page 17

ID: 4605000_1001_04 ID: 4605130_1001_01


One heating circuit without mixer, one heating circuit with mixer and One heating circuit without mixer and two heating circuits with mixer
DHW heating (optional solar DHW heating) and DHW heating (optional solar DHW heating)
See page 12 See page 21

ID: 4605001_1001_04 ID: 4605002_1001_04


5822 470 GB

System examples VIESMANN 7


Boiler floorstanding, 18 to 100 kW (cont.)

2.2 One heating circuit without mixer or DHW heating (optional solar DHW heating)
DHW heating without a solar thermal system
If the temperature falls below the set DHW temperature selected at
control unit 2, the burner of boiler 1 starts and circulation pump
qE of DHW cylinder qP or qR runs.
Within the periods selected at control unit 2, DHW is heated with and
without priority.

DHW heating by the solar thermal system


Solar circuit pump R1 wE starts and DHW cylinder qR is heated up, if
the temperature differential between collector temperature sensor S1
2 wQ and cylinder temperature sensor S2 qT exceeds the start temper-
ID: 4605000_1001_04
ature differential.
Pump R1 wE stops if:
Applications The actual temperature drops below the stop temperature differen-
Heating system with DHW heating tial
The electronic temperature limit (max. at 90 C) of Vitosolic 100 (type
Main components SD1) wZ is exceeded
Oil boiler, gas boiler, oil condensing boiler or gas condensing boiler, The temperature selected at high limit safety cut-out (STB) qZ (if
18 to 100 kW installed) is reached
DHW cylinders (dual mode) The requirements for the additional function are achieved through cir-
Solar thermal system culation pump R2 wR.

Function description Reheating suppression


Heating circuit eP and DHW cylinder qP/qR are regulated by boiler This function is activated only if the KM BUS is connected to the
heating circuit controller 1. The heating circuit and DHW cylinder are Vitosolic 100 (type SD1) wZ.
each supplied by a separate circulation pump eQ and qE. While DHW cylinder qR is being heated by the solar thermal system,
Vitosolic 100 (type SD1) wZ suppresses reheating by boiler 1.
Heating mode In boiler circuit control unit 2, coding address "67" defaults a third set
The boiler heating circuit controller regulates the boiler water temper- DHW temperature. This value must be below the first set DHW tem-
ature in weather-compensated or heat demand-dependent mode (= perature. DHW cylinder qR will only be heated by boiler 1 if the third
flow temperature of the heating circuit without mixer). set DHW temperature is not achieved by the solar thermal system.

5822 470 GB

8 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW (cont.)

Hydraulic installation scheme ID: 4605000_1001_04

30

--KM-Bus--
--26/S1--

--S1--
--S2--
Vorlauf

21 26
20

--R1--
--R2--
--230V-- 31
Ruecklauf
--2/20A1--

22 2

13
23 --2/21--
---26/R1--

WW

12 --2/28--
25
-26/R1-

3
16
--26/R2--

--2/1--

-- 4
24
--2/3--
--2/5-- 11

15
--26/S2--

1
KW 10 / 14
--KM-Bus--
--5--
--1--

--3--

2
--21--
--28--
--20A1--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
5822 470 GB

System examples VIESMANN 9


Boiler floorstanding, 18 to 100 kW (cont.)

Equipment required

ID: 4605000_1001_04
Pos. Description Part no.
1 Boiler with As per Viessmann pricelist
2 Control unit Standard delivery, boiler, pos. 1
Vitorond 100 or 111 with
Vitotronic 150, type KB2, or
Vitotronic 200, type KW4
Vitola 200 or 222 with
Vitotronic 100, type KC2, or
Vitotronic 150, type KB1, or
2 Vitotronic 200, type KW1
Vitoladens 300-T with
Vitotronic 150, type KB1, or
Vitotronic 200, type KW1
Vitoladens 300-C with
Vitotronic 200, type KW6
Vitogas 200-F with
Vitotronic 150, type KB2, or
Vitotronic 200, type KW4
Vitocrossal 300 with
Vitotronic 200, type KW1
3 Outside temperature sensor ATS (only for weather-compensated mode) Standard delivery, Vitotronic, pos.
2
4 Boiler water temperature sensor KTS Standard delivery, Vitotronic, pos.
2
5 Extension with a two-stage/modulating burner (not for the Vitotronic 200, type KW6) Standard delivery, boiler, pos. 1
DHW heating by the boiler
qP DHW cylinder (integrated for the Vitorond 111 and Vitola 222) As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, Vitotronic, pos.
2
qW DHW circulation pump ZP (only for the Vitotronic 200) As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB (for system connection in standard delivery) As per Viessmann pricelist
DHW heating by the solar thermal system (not with the Vitorond 111 or Vitola 222)
qQ Cylinder temperature sensor STS Standard delivery, Vitotronic, pos.
2
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist
qR Dual mode DHW cylinder As per Viessmann pricelist
qT Cylinder temperature sensor SOL Standard delivery Vitosolic 100
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wZ Vitosolic 100, type SD1 Z007 387
wQ Collector temperature sensor KOL Standard delivery Vitosolic 100
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump R1 Standard delivery, Solar-Divicon
wR Circulation pump R2 (transfer) on-site
wT Automatic thermostatic mixing valve 7438 940
wU Junction box on-site
eP Heating circuit I
eQ Heating circuit pump, heating circuit A1 As per Viessmann pricelist
or
Divicon
Accessories
rP External extension H5 (not for the Vitotronic 200, type KW6) 7199 249
rQ Motorised flue gas damper (only for the Vitogas 200-F) As per Viessmann pricelist
rW KM BUS distributor, for when there are several KM BUS subscribers 7415 028
rE Control module V (only for the Vitotronic 200; not for type KW6) 7143 513
rR Central fault message facility on-site
rT Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
rZ Flue gas temperature sensor AGS (only for the Vitotronic 200; not for type KW6) 7450 630
rU Radio clock receiver 7450 563
rI Vitotrol 100 UTDB (with the Vitotronic 100, type KC2) Z007 691
rO Vitocom 100, type GSM, for the Vitotronic 150 and 200 Z004 594 or Z004 615
5822 470 GB

10 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW (cont.)

Electrical installation scheme

3
40 230 V/ 50 Hz

3
20 A1 M 31

40
7 7
41 41 41 2
230 V/ 50 Hz

4
150 M 41
2
X12 X12 47

3
21 M UPSB 13
3 43
28 M ZP 12

103
20 M2
2
145 S 44

157
52 M2
42

145 145
2
145 KM BUS 45 / 49
2
145
3
L,N, 230 V/ 50 Hz
2 3
15 AGS 46 R1 M R1 23
27
2 3
R2 M R2
Low voltage

3 KTS 4 24

2 3
STS 145 STB 16
5 11
2
2(3) S1 KOL 21
1 ATS 3 / 47
2
S2 SOL 15
3
191 90 5
26

2
103 48

ID: 4605000_1001_04
5822 470 GB

System examples VIESMANN 11


Boiler floorstanding, 18 to 100 kW (cont.)

2.3 One heating circuit without mixer, one heating circuit with mixer and DHW heating
(optional solar DHW heating)
Within the periods selected at control unit 2, DHW is heated with and
without priority.
In the case of absolute priority, heating circuit pump rE of the heating
circuit with mixer is switched off and mixer rR is closed. With modu-
lating priority control, heating circuit pump rE of the heating circuit with
mixer remains switched on, and mixer rR closes far enough to enable
the boiler water temperature set for cylinder heating to be reached. In
this case, DHW cylinder qP or qR and heating circuit with mixer rP
2 are heated simultaneously.

ID: 4605001_1001_04 DHW heating by the solar thermal system


Solar circuit pump R1 wE starts and DHW cylinder qR is heated up, if
the temperature differential between collector temperature sensor S1
Applications wQ and cylinder temperature sensor S2 qT exceeds the start temper-
Heating system with different heat sources and methods of DHW heat- ature differential.
ing Pump R1 wE stops if:
One heating circuit without mixer The actual temperature drops below the stop temperature differen-
One heating circuit with 3-way mixer tial
The electronic temperature limit (max. at 90 C) of Vitosolic 100 (type
Main components SD1) wZ is exceeded
Oil boiler, gas boiler, oil condensing boiler or gas condensing boiler, The temperature selected at high limit safety cut-out (STB) qZ (if
18 to 100 kW installed) is reached
Heating circuit distribution The requirements for the additional function are achieved through cir-
DHW cylinders (dual mode) culation pump R2 wR.
Solar thermal system
Reheating suppression
Function description This function is activated only if the KM BUS is connected to the
Heating circuits eP/rP and DHW cylinder qP/qR are regulated by Vitosolic 100 (type SD1) wZ.
boiler heating circuit controller 1. The heating circuits and DHW cyl- While DHW cylinder qR is being heated by the solar thermal system,
inder are each supplied by a separate circulation pump eQ/rE and Vitosolic 100 (type SD1) wZ suppresses reheating by boiler 1.
qE. In boiler circuit control unit 2, coding address "67" defaults a third set
DHW temperature. This value must be below the first set DHW tem-
Heating mode perature. DHW cylinder qR will only be heated by boiler 1 if the third
The boiler heating circuit controller regulates the boiler water temper- set DHW temperature is not achieved by the solar thermal system.
ature in weather-compensated mode (= flow temperature of the heat-
ing circuit without mixer) and the temperature level of the heating circuit
via an extension kit for one heating circuit with mixer.

DHW heating without a solar thermal system


If the temperature falls below the set DHW temperature selected at
control unit 2, the burner of boiler 1 starts and circulation pump
qE of DHW cylinder qP or qR runs.
5822 470 GB

12 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW (cont.)

Hydraulic installation scheme ID: 4605001_1001_04

30 40

--KM-Bus--
--26/S1--

41
--2/2M2--

--S1--
--S2--
Vorlauf

--2/20M2--
21 26 42
20

--R1--
--R2--
--230V-- 31 43
--2/20A1-- --2/20M2--
Ruecklauf

--2/52M2--
22 45
2

13
23 --2/21--
---26/R1--

WW

12 --2/28--
25
-26/R1-

3
16
--26/R2--

--2/1--

-- 4
24
--2/3--
--2/5-- 11

15
--26/S2--

1
KW 10 / 14
--KM-Bus--

--2M2--
--5--
--1--

--3--

2
--21--
--28--
--20A1--
--52M2--
--20M2--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
5822 470 GB

System examples VIESMANN 13


Boiler floorstanding, 18 to 100 kW (cont.)

Equipment required

ID: 4605001_1001_04
Pos. Description Part no.
1 Boiler with As per Viessmann pricelist
2 Control unit Standard delivery, boiler, pos. 1
Vitorond 100 or 111 with
Vitotronic 200, type KW5
Vitola 200 or 222 with
Vitotronic 200, type KW2
Vitoladens 300-T with
Vitotronic 200, type KW2
2 Vitoladens 300-C with
Vitotronic 200, type KW6
Vitogas 200-F with
Vitotronic 200, type KW5
Vitocrossal 300 with
Vitotronic 200, type KW2
3 Outside temperature sensor ATS Standard delivery, Vitotronic, pos.
2
4 Boiler water temperature sensor KTS Standard delivery, Vitotronic, pos.
2
5 Extension with a two-stage/modulating burner (not for the Vitotronic 200, type KW6) Standard delivery, boiler, pos. 1
DHW heating by the boiler
qP DHW cylinder (integrated for the Vitorond 111 and Vitola 222) As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, Vitotronic, pos.
2
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB (for system connection in standard delivery) As per Viessmann pricelist
DHW heating by the solar thermal system (not with the Vitorond 111 or Vitola 222)
qQ Cylinder temperature sensor STS Standard delivery, Vitotronic, pos.
2
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist
qR Dual mode DHW cylinder As per Viessmann pricelist
qT Cylinder temperature sensor SOL Standard delivery Vitosolic 100
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wZ Vitosolic 100, type SD1 Z007 387
wQ Collector temperature sensor KOL Standard delivery Vitosolic 100
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump R1 Standard delivery, Solar-Divicon
wR Circulation pump R2 (transfer) on-site
wT Automatic thermostatic mixing valve 7438 940
wU Junction box on-site
5822 470 GB

14 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW (cont.)

ID: 4605001_1001_04
Pos. Description Part no.
eP Heating circuit I
eQ Heating circuit pump, heating circuit A1 As per Viessmann pricelist
or
Divicon
rP Heating circuit II in conjunction with the Vitotronic 200, type KW2 and KW5
rR Extension kit for one heating circuit with mixer M2 7450 650
Components:
rQ Flow temperature sensor M2 (contact temperature sensor)
and
rT Mixer motor
or 2
rQ Contact temperature sensor 7183 288
or
Immersion temperature sensor (incl. sensor well) 7450 641
and
rT Mixer motor M2 for flanged mixer and plug As per Viessmann pricelist
rW Temperature limiter for an underfloor heating circuit 7151 728 or 7151 729
rE Heating circuit pump M2 and 3-way mixer As per Viessmann pricelist
or
Divicon
rP Heating circuit II in conjunction with the Vitotronic 200, type KW6
rR Extension kit for one heating circuit with mixer M2 7301 063
Components:
rQ Flow temperature sensor M2 (contact temperature sensor)
and
rT Mixer PCB with mixer motor
or
rR Extension kit for one heating circuit with mixer M2 7301 062
Components:
rQ Mixer PCB and flow temperature sensor M2 (contact temperature sensor)
rT Mixer motor 7450 657
or
Mixer motor M2 for flanged mixer and plug As per Viessmann pricelist
rW Temperature limiter for an underfloor heating circuit 7151 728 or 7151 729
rE Heating circuit pump M2 and 3-way mixer As per Viessmann pricelist
or
Divicon
Accessories
tP External extension H5 (not for the Vitotronic 200, type KW6) 7199 249
tQ Motorised flue gas damper (only for the Vitogas 200-F) As per Viessmann pricelist
tW KM BUS distributor, for where there are several KM BUS subscribers 7415 028
tE Control module V (only for the Vitotronic 200; not for type KW6) 7143 513
tR Central fault message facility on-site
tT Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
tZ Flue gas temperature sensor AGS (only for the Vitotronic 200; not for type KW6) 7450 630
tU Radio clock receiver 7450 563
tI Vitocom 100, type GSM, for the Vitotronic 200 Z004 594 or Z004 615
5822 470 GB

System examples VIESMANN 15


Boiler floorstanding, 18 to 100 kW (cont.)

Electrical installation scheme

3
40 230 V/ 50 Hz

3
20 A1 M 31

50
7 7
2 41 41 41
230 V/ 50 Hz

4
150 M 51
2
X12 X12 47

3
21 M UPSB 13
3 53
28 M ZP 12

3 103
20 M2 M M2 43
2
145 S 54
42
157
4
52 M2 M M2 45
52

145 145
2
145 KM BUS 55 / 58
2
145
3
L,N, 230 V/ 50 Hz
2 3
15 AGS 56 R1 M R1 23
27
2 3
R2 M R2
Low voltage

3 KTS 4 24

2 3
STS 145 STB 16
5 11
2
2(3) S1 KOL 21
1 ATS 3 / 57
2
S2 SOL 15
3
191 90 5
26

2
2 M2 M2 41

ID: 4605001_1001_04
5822 470 GB

16 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW (cont.)

2.4 One heating circuit without mixer, one heating circuit with mixer and DHW heating
Function description
Heating circuits eP/rP and DHW cylinder qP are regulated by boiler
heating circuit controller 1. The heating circuits and DHW cylinder
are each supplied by a separate circulation pump eQ/rE and qE.

Heating mode
The boiler heating circuit controller regulates the boiler water temper-
ature in weather-compensated mode (= flow temperature of the heat-
ing circuit without mixer) and the temperature level of the heating circuit
via an extension kit for one heating circuit with mixer.
2
ID: 4605130_1001_01
DHW heating
If the temperature falls below the DHW temperature selected at control
Applications unit 2, the burner of boiler 1 starts and circulation pump qE of DHW
Heating system with different heat sources and methods of DHW heat- cylinder qP runs.
ing Within the periods selected at control unit 2, DHW is heated with and
One heating circuit without mixer without priority.
One heating circuit with 3-way mixer In the case of absolute priority, heating circuit pump rE of the heating
circuit with mixer is switched off and mixer rR is closed. With modu-
Main components lating priority control, heating circuit pump rE of the heating circuit with
Oil boiler, gas boiler, oil condensing boiler or gas condensing boiler, mixer remains switched on, and mixer rR closes far enough to enable
18 to 100 kW the boiler water temperature set for cylinder heating to be reached. In
Heating circuit distribution this case, DHW cylinder qP and heating circuit with mixer rP are
DHW cylinder heated simultaneously.
5822 470 GB

System examples VIESMANN 17


Boiler floorstanding, 18 to 100 kW (cont.)

Hydraulic installation scheme ID: 4605130_1001_01

30 40
41
--2/2M2--
--2/20M2--
42
31 43
--2/20A1-- --2/20M2--

--2/52M2--
45
2

13
--2/21--

WW

--2/28--
12
3
--2/1--

4
11 --2/3--
--2/5--

1
KW 10
--KM-Bus--

--2M2--
--5--
--1--

--3--

2
--21--
--28--
--20A1--
--52M2--
--20M2--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605130_1001_01
Pos. Description Part no.
1 Boiler with As per Viessmann pricelist
2 Control unit Standard delivery, boiler, pos. 1
Vitorond 100 or 111 with
Vitotronic 200, type KW5
Vitola 200 or 222 with
Vitotronic 200, type KW2
Vitoladens 300-T with
Vitotronic 200, type KW2
Vitoladens 300-C with
Vitotronic 200, type KW6
Vitogas 200-F with
Vitotronic 200, type KW5
Vitocrossal 300 with
Vitotronic 200, type KW2
3 Outside temperature sensor ATS Standard delivery, Vitotronic, pos.
2
5822 470 GB

4 Boiler water temperature sensor KTS Standard delivery, Vitotronic, pos.


2
5 Extension with a two-stage/modulating burner (not for the Vitotronic 200, type KW6) Standard delivery, boiler, pos. 1

18 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW (cont.)

ID: 4605130_1001_01
Pos. Description Part no.
DHW heating by the boiler
qP DHW cylinder (integrated for the Vitorond 111 and Vitola 222) As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, Vitotronic, pos.
2
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB (for system connection in standard delivery) As per Viessmann pricelist
eP Heating circuit I
eQ Heating circuit pump, heating circuit A1 As per Viessmann pricelist
or
Divicon
rP Heating circuit II in conjunction with the Vitotronic 200, type KW2 and KW5 2
rR Extension kit for one heating circuit with mixer M2 7450 650
Components:
rQ Flow temperature sensor M2 (contact temperature sensor)
and
rT Mixer motor
or
rQ Contact temperature sensor 7183 288
or
Immersion temperature sensor (incl. sensor well) 7450 641
and
rT Mixer motor M2 for flanged mixer and plug As per Viessmann pricelist
rW Temperature limiter for an underfloor heating circuit 7151 728 or 7151 729
rE Heating circuit pump M2 and 3-way mixer As per Viessmann pricelist
or
Divicon
rP Heating circuit II in conjunction with the Vitotronic 200, type KW6
rR Extension kit for one heating circuit with mixer M2 7301 063
Components:
rQ Flow temperature sensor M2 (contact temperature sensor)
and
rT Mixer PCB with mixer motor
or
rR Extension kit for one heating circuit with mixer M2 7301 062
Components:
rQ Mixer PCB and flow temperature sensor M2 (contact temperature sensor)
rT Mixer motor 7450 657
or
Mixer motor M2 for flanged mixer and plug As per Viessmann pricelist
rW Temperature limiter for an underfloor heating circuit 7151 728 or 7151 729
rE Heating circuit pump M2 and 3-way mixer As per Viessmann pricelist
or
Divicon
Accessories
tP External extension H5 (not for the Vitotronic 200, type KW6) 7199 249
tQ Motorised flue gas damper (only for the Vitogas 200-F) As per Viessmann pricelist
tW KM BUS distributor, for when there are several KM BUS subscribers 7415 028
tE Control module V (only for the Vitotronic 200; not for type KW6) 7143 513
tR Central fault message facility on-site
tT Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
tZ Flue gas temperature sensor AGS (only for the Vitotronic 200; not for type KW6) 7450 630
tU Radio clock receiver 7450 563
tI Vitocom 100, type GSM, for the Vitotronic 200 Z004 594 or Z004 615
5822 470 GB

System examples VIESMANN 19


Boiler floorstanding, 18 to 100 kW (cont.)

Electrical installation scheme

3
40 230 V / 50 Hz

3
20 A1 M 31

50
7 7
2 41 41 41
230 V / 50 Hz

4
150 M 51
2
X12 X12 47

3
21 M UPSB 13
3 53
28 M ZP 12

3 103
20 M2 M M2 43
2
145 S 54
42
157
4
52 M2 M M2 45
52

145 145
2
145 KM BUS 55 / 58
145

15 2
AGS 56
2
Low voltage

3 KTS 4
2
5 STS 11

2(3)
1 ATS 3 / 57

3
191 90 5

2
2 M2 M2 41

ID: 4605130_1001_01
5822 470 GB

20 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW (cont.)

2.5 One heating circuit without mixer and two heating circuits with mixer and DHW heating
(optional solar DHW heating)
Within the periods selected at control unit 2, DHW is heated with and
without priority.
In the case of absolute priority, heating circuit pumps eQ/rR/tR are
switched off and mixers rT/tT are closed. With modulating priority
control of the heating circuits with mixer, heating circuit pumps rR/
tR remain switched on, and mixers rT/tT close far enough to enable
the boiler water temperature set for cylinder heating to be reached. In
this case, DHW cylinder qP or qR and heating circuit with mixer rP
and tP are heated simultaneously. 2
ID: 4605002_1001_04 DHW heating by the solar thermal system
Solar circuit pump R1 wE starts and DHW cylinder qR is heated up, if
the temperature differential between collector temperature sensor S1
Applications wQ and cylinder temperature sensor S2 qT exceeds the start temper-
Heating system with different heat sources and methods of DHW heat- ature differential.
ing Pump R1 wE stops if:
One heating circuit without mixer The actual temperature drops below the stop temperature differen-
Two heating circuits with 3-way mixer tial
The electronic temperature limit (max. at 90 C) of Vitosolic 100 (type
Main components SD1) wZ is exceeded
Oil boiler, gas boiler, oil condensing boiler or gas condensing boiler, The temperature selected at high limit safety cut-out (STB) qZ (if
18 to 100 kW installed) is reached
Heating circuit distribution The requirements for the additional function are achieved through cir-
DHW cylinders (dual mode) culation pump R2 wR.
Solar thermal system
Reheating suppression
Function description This function is activated only if the KM BUS is connected to the
Heating circuits eP/rP/tP and DHW cylinder qP/qR are regulated by Vitosolic 100 (type SD1) wZ.
boiler heating circuit controller 1. The heating circuits and DHW cyl- While DHW cylinder qR is being heated by the solar thermal system,
inder are each supplied by a separate circulation pump eQ/rR/tR and Vitosolic 100 (type SD1) wZ suppresses reheating by boiler 1.
qE. In boiler circuit control unit 2, coding address "67" defaults a third set
DHW temperature. This value must be below the first set DHW tem-
Heating mode perature. DHW cylinder qR will only be heated by boiler 1 if the third
The boiler heating circuit controller regulates the boiler water temper- set DHW temperature is not achieved by the solar thermal system.
ature in weather-compensated mode (= flow temperature of the heat-
ing circuit without mixer) and the temperature level of the heating circuit
via an extension kit for one heating circuit with mixer.

DHW heating without a solar thermal system


If the temperature falls below the set DHW temperature selected at
control unit 2, the burner of boiler 1 starts and circulation pump
qE of DHW cylinder qP or qR runs.
5822 470 GB

System examples VIESMANN 21


Boiler floorstanding, 18 to 100 kW (cont.)

Hydraulic installation scheme ID: 4605002_1001_04

30 40 50

--KM-Bus--
--26/S1--

52
--51/2--

--S1--
--S2--
42
Vorlauf

--41/2-- --51/20--
21 26 53
20 --R1--
--R2-- 31 44 54
--230V--

--2/20A1-- --41/20-- --51/20--


Ruecklauf

--41/52-- --51/52--

2 22 45 55

--KM-Bus--

--KM-Bus--
13
23 --2/21--
---26/R1--

--2--

--2--
41 51

--40--
--40--
--52--

--52--
--20--

--20--
WW

12 --2/28--

--156--

--156--
25

68

--40--
--230V--
-26/R1-

3
16
--26/R2--

--2/1--

-- 4
24
--2/3--
--2/5-- 11

15
--26/S2--

1
KW 10 / 14
--KM-Bus--
--191--
--15--
--1--

--5--
--3--

2
--20A1--
--41--
--21--
--28--
--50--
--156--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
5822 470 GB

22 VIESMANN System examples


Boiler floorstanding, 18 to 100 kW (cont.)

Equipment required

ID: 4605002_1001_04
Pos. Description Part no.
1 Boiler with As per Viessmann pricelist
2 Control unit Standard delivery, boiler, pos. 1
Vitola 200 with the Vitotronic 300, type KW3
Vitoladens 300-T with the Vitotronic 300, type KW3
Vitocrossal 300 with the Vitotronic 300, type KW3
3 Outside temperature sensor ATS Standard delivery, Vitotronic, pos.
2
4 Boiler water temperature sensor KTS Standard delivery, Vitotronic, pos.
2 2
5 Two-stage/modulating burner extension Standard delivery, boiler, pos. 1
DHW heating by the boiler
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, Vitotronic, pos.
2
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB (for system connection in standard delivery) As per Viessmann pricelist
DHW heating by the solar thermal system
qQ Cylinder temperature sensor STS Standard delivery, Vitotronic, pos.
2
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist
qR Dual mode DHW cylinder As per Viessmann pricelist
qT Cylinder temperature sensor SOL Standard delivery Vitosolic 100
SD1
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wZ Vitosolic 100, type SD1 Z007 387
wQ Collector temperature sensor KOL Standard delivery
Vitosolic 100 SD1
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump R1 Standard delivery, Solar-Divicon
wR Circulation pump R2 (transfer) on-site
wT Automatic thermostatic mixing valve 7438 940
wU Junction box on-site
eP Heating circuit I
eQ Heating circuit pump, heating circuit A1 As per Viessmann pricelist
or
Divicon
rP/tP Heating circuits II and III
rQ/tQ Extension kit for one heating circuit with mixer M2/M3 7301 063
Components:
rW/tW Flow temperature sensor M2/M3 (contact temperature sensor)
and
rT/tT Mixer PCB with mixer motor
or
rQ/tQ Extension kit for one heating circuit with mixer M2/M3 7301 062
Components:
rW/tW Mixer PCB and flow temperature sensor (contact temperature sensor)
rT/tT Mixer motor M2/M3 As per Viessmann pricelist
tE Temperature limiter for an underfloor heating circuit 7151 728 or 7151 729
rR/tR Heating circuit pump M2/M3 and 3-way mixer As per Viessmann pricelist
or
Divicon
Accessories
zW KM BUS distributor, for when there are several KM BUS subscribers 7415 028
zE Control module V 7143 513
zR Central fault message facility on-site
zT Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
zZ Flue gas temperature sensor AGS 7450 630
zU Radio clock receiver 7450 563
5822 470 GB

zI Power distributor 7415 030


zO Vitocom 100, type GSM Z004 594 or Z004 615

System examples VIESMANN 23


Boiler floorstanding, 18 to 100 kW (cont.)

Electrical installation scheme

zI
5 3
f 230 V/50 Hz
2 3
aBH
3
f aBH

aBH
2 3
s A1 M eQ
7
fA fA
230 V / 50 Hz

rQ
f
3 3
sA M UPSB qE s M M2 rR
3 4
sK M ZP qW gS M M2 rT
3 2
g S ? J M2 rW

aVG

tQ
2
aVG f J J tE
2 3 3
aG J AGS wW s M M3 tR
2 4
% J KTS 4 gS M M3 tT
Low voltage

2 2
J STS qQ ? J M3 tW
2(3)
! J ATS 3/zU aVG
3
a:A l 5
zW zE
2
aVG a-D
2
aVG aVG
2 2
aVG aBJ S zR
2
aVG J KM BUS zT/zO
2 3
230 V / 50 Hz

aVG L,N,? 230 V/50 Hz


wU
3
R1 M R1 wE
3
R2 M R2 wR
3
aVG J STB qZ
2
S1 J KOL wQ
Low voltage

2
S2 J SOL qT

wZ

ID: 4605002_1001_04
5822 470 GB

24 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW

3.1 Overview of sample applications


In the following sample applications, DHW heating is shown with a sep- One heating circuit without mixer, two heating circuits with mixer
arate DHW cylinder. The sample applications also apply to boilers See page 48
where DHW is heated by an integral instantaneous water heater and
boiler with internal cylinder. In that case, the cylinder temperature sen-
sor is factory-fitted to the boiler.

ID: 4605134_1001_01
One heating circuit without mixer One heating circuit without mixer
See page 26 See page 54

ID: 4605131_1001_01 ID: 4605135_1001_01


One heating circuit with mixer Two heating circuits with mixer, low loss header
See page 31 See page 59

ID: 4605132_1001_01 ID: 4605136_1001_01


Without/with mixer, system separation or sub-mounting/assembly kit Without/with mixer, system separation
See page 36 See page 64

ID: 4605133_1001_01 ID: 4605137_1001_01


Injection control (Vitopend 200-W only) With mixer and low loss header, without/with system separation
See page 43 See page 69

ID: 4605006_1001_03 ID: 4605138_1001_01


5822 470 GB

System examples VIESMANN 25


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.2 One heating circuit without mixer


Within the periods selected at control unit 2, DHW heating has pri-
ority.
DHW circulation pump ZP qW is connected, subject to system equip-
ment, either to internal extension H1 4/ H2 5 or to extension AM1
6.

Gas combi boiler


In the case of DHW demand (draw-off), the 3-way valve is changed
over to supply DHW (plate heat exchanger). The integral circulation
pump is switched on. The outlet temperature is regulated to the set
ID: 4605131_1001_01 value.
The periods for the comfort function can be set at the time switch.

Applications Boiler with internal cylinder


If the cylinder temperature sensor recognises a temperature lower
Heating system with one heating circuit: than the set default temperature, the 3-way valve is changed over to
Unregulated radiator heating circuit eP supply the internal cylinder. The integral circulation pump is switched
on.
3 DHW heating by the boiler and with a solar thermal system Heating stops when the set temperatures have been reached at the
cylinder temperature sensor and at the outlet temperature sensor. The
Main components cylinder primary pump and 3-way valve remain on for a further 30s.
Conventional gas boiler 1 Vitopend 200-W
or DHW heating by the solar thermal system
Gas condensing boiler 1 Vitodens 200-W, 222-F, 222-W, 300-W, Solar circuit pump wE starts and DHW cylinder qE is heated up, if the
333-F temperature differential between collector temperature sensor wQ and
or cylinder temperature sensor qR exceeds the start temperature differ-
Oil condensing boiler 1 Vitoladens 300-W, 333-F ential.
Vitotronic 100 (for constant temperature mode) 2 or Vitotronic 200
(for weather-compensated mode) 2 Solar circuit pump wE stops if:
DHW heating by a solar thermal system (only with the Vitopend 200- The actual temperature drops below the stop temperature differen-
W, Vitodens 200-W, 300-W and Vitoladens 300-W): tial
Dual mode DHW cylinder qE The electronic temperature limit (max. 90 C) of the solar control unit
Solar thermal system wP (type SM1) wR is exceeded
The temperature selected at high limit safety cut-out (STB) qT (if
Function description installed) is reached
The circulation pump integrated into boiler 1 supplies either heating
circuit eP or DHW cylinder qE via the integral 3-way valve. The requirements for the auxiliary function (see Vitosol technical
guide) are met by circulation pump qU.
Heating mode
The 3-way diverter valve is changed over to supply the heating circuit, Suppression of reheating of the DHW cylinder by the boiler in
and the integral circulation pump starts. conjunction with solar control module (type SM1)
Reheating suppression takes place in two stages.
Constant temperature mode Reheating of DHW cylinder qE by boiler 1 is suppressed, as soon as
Control unit 2 of boiler 1 (via room temperature controller uP/uQ) DHW cylinder qE is heated by collectors wP. For this, the set DHW
regulates the boiler water temperature (= flow temperature of heating temperature for reheating is reduced by boiler 1. Suppression
circuit without mixer eP) in room temperature-dependent mode. Upon remains active for a certain time after solar circuit pump wE has been
demand by room temperature controller uP/uQ, the boiler water tem- switched off.
perature is regulated to the set value. In the case of uninterrupted heating by collectors wP (> 2 h) boiler
1 will only reheat, if the set cylinder temperature (coding address
Weather-compensated mode "67") selected at boiler circuit control unit 2 is not achieved.
Control unit 2 of boiler 1 regulates the boiler water temperature (= In control unit 2, coding address "67" defaults a third set DHW tem-
flow temperature of heating circuit without mixer eP) in weather-com- perature (setting range 10 to 95 C). This value must be below the first
pensated mode. set DHW temperature.
DHW cylinder qE will only be heated by boiler 1, if this set value
DHW heating by boiler cannot be achieved by the solar thermal system.

Gas system boiler


If the actual temperature falls below the DHW temperature set at con-
trol unit 2, the 3-way valve changes over to supply DHW cylinder
qE. The integral circulation pump is switched on.
5822 470 GB

26 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Hydraulic installation scheme ID: 4605131_1001_01

--KM-Bus--
--24/6--

--6--
--5--
Vorlauf

21 24
20

--24--
--22--
--230V--
Ruecklauf

30

22

23
---24/24--

3
WW

12 --x/x--
16

3
--2/X3--
-24/24-

15
--24/22--

17 --
--2/5-- 11 1

14
--24/5--
--KM-Bus--
--KM-Bus--

--KM-Bus--

KW 13
--X3--
--5--

2 4/ 5 7 6
--A2--
--40--
--96--

--28--

--40--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
DHW circulation pump ZP qW is connected, subject to system equip-
ment, either to internal extension H1 4/ H2 5 or to extension AM1
6.

Equipment required

ID: 4605131_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
Heating circuit without mixer eP:
2 Constant temperature control unit
or
Control unit for weather-compensated operation
5822 470 GB

3 Outside temperature sensor ATS (only for weather-compensated mode)

System examples VIESMANN 27


Boiler wall mounted, 3.8 to 35 kW (cont.)

ID: 4605131_1001_01
Pos. Description Part no.
Room temperature controller/remote control
Constant temperature mode
uQ Vitotrol 100, type UTA 7170 149
or
uW Vitotrol 100, type UTDB Z007 691
or
Vitotrol 100, type UTDB-RF Z007 692
Weather-compensated mode
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
or
Vitohome 300 As per Viessmann pricelist
DHW heating via boiler 1
qQ Cylinder temperature sensor STS Connection set standard delivery
qW DHW circulation pump ZP As per Vitoset pricelist
DHW heating via solar thermal system wP
qE Dual mode DHW cylinder and connection set As per Viessmann pricelist
qQ Cylinder temperature sensor STS part of the standard delivery of pos.
3 13
qR Cylinder temperature sensor SOL part of the standard delivery of pos.
24
qT High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wR Solar control module, type SM1 7429 073
wQ Collector temperature sensor KOL part of the standard delivery of pos.
24
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump Standard delivery, Solar-Divicon
qZ Automatic thermostatic mixing valve 7438 940
qU Circulation pump (transfer) on-site
wT Junction box on-site
Heating circuit without mixer eP
Accessories (optional)
4 Internal extension H1 (standard delivery for the Vitodens 222-W/300-W/333-F and Vitoladens) 7179 057
5 Internal extension H2 7179 144
6 Extension AM1 7429 152
7 Extension EA1 7429 151
8 External extension H4 (Vitotrol 100, type UTDB uW for LV connection) 7197 227
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
Solar control module, type SM1 wR
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
5822 470 GB

28 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ ZP 12 SLP
40 7 L

5
2
LON 69
2 L
96
5 STS 11 96 N
L
X3.7 P
X3.6 157 M 61
S N
X3.5
X3.4 3
Low voltage

N
28 M
X3.3 1~ ZP 12 SLP
67 L

X3.2
ATS 3 68
X3.1
3
2 145
1 3
145 2
KM BUS 65 66 70
1
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2 145 6
145
1 1

ID: 4605131_1001_01

Note
The cylinder primary pump (SLP) is integrated and fully wired with the
Vitodens 222-F, 222-W and 333-F (type FS3B).
5822 470 GB

System examples VIESMANN 29


Boiler wall mounted, 3.8 to 35 kW (cont.)

6
7
N
40A 40
L
N
40A 40 24
L
N
A1
L
N
A2 M
1~ ZP 12
L

2 2
145
1 1

24
6
N
40A 40
L
3 24
N
M
1~ 23
L
25
STB 15
N
22 M
1~ 17
L
2
PWM
1
4
6 KOL 21
3
2
5 SOL 14
1
2
1 145

ID: 4605131_1001_01

5822 470 GB

30 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.3 One heating circuit with mixer


Within the periods selected at control unit 2, DHW heating has pri-
ority.
DHW circulation pump ZP qW is connected, subject to system equip-
ment, either to internal extension H1 4/ H2 5 or to extension AM1
6.

Gas combi boiler


In the case of DHW demand (draw-off), the 3-way valve is changed
over to supply DHW (plate heat exchanger). The integral circulation
pump is switched on. The outlet temperature is regulated to the set
ID: 4605132_1001_01 value.
The periods for the comfort function can be set at the time switch.

Applications Boiler with internal cylinder


If the cylinder temperature sensor recognises a temperature lower
Heating system with one heating circuit: than the set default temperature, the 3-way valve is changed over to
Regulated radiator heating circuit rP supply the internal cylinder. The integral circulation pump is switched
on.
DHW heating by the boiler and with a solar thermal system Heating stops when the set temperatures have been reached at the 3
cylinder temperature sensor and at the outlet temperature sensor. The
Main components cylinder primary pump and 3-way valve remain on for a further 30s.
Conventional gas boiler 1 Vitopend 200-W
or DHW heating by the solar thermal system
Gas condensing boiler 1 Vitodens 200-W, 222-F, 222-W, 300-W, Solar circuit pump wE starts and DHW cylinder qE is heated up, if the
333-F temperature differential between collector temperature sensor wQ and
or cylinder temperature sensor qR exceeds the start temperature differ-
Oil condensing boiler 1 Vitoladens 300-W, 333-F ential.
Vitotronic 100 (for constant temperature mode) 2 or Vitotronic 200
(for weather-compensated mode) 2 Solar circuit pump wE stops if:
DHW heating by a solar thermal system (only with the Vitopend 200- The actual temperature drops below the stop temperature differen-
W, Vitodens 200-W, 300-W and Vitoladens 300-W): tial
Dual mode DHW cylinder qE The electronic temperature limit (max. 90C) of the solar control unit
Solar thermal system wP (type SM1) wR is exceeded
The temperature selected at high limit safety cut-out (STB) qT (if
Function description installed) is reached
The circulation pump integrated into boiler 1 supplies either heating
circuit rP or DHW cylinder qE via the integral 3-way valve. The requirements for the auxiliary function (see Vitosol technical
On-site heating circuit pump M2 rR supplies radiator circuit rP. guide) are met by circulation pump qU.

Heating mode Suppression of reheating of the DHW cylinder by the boiler in


The 3-way diverter valve is changed over to supply the heating circuit, conjunction with solar control module (type SM1)
and the integral circulation pump starts. Reheating suppression takes place in two stages.
Reheating of DHW cylinder qE by boiler 1 is suppressed, as soon as
Heating circuit with mixer for weather-compensated mode DHW cylinder qE is heated by collectors wP. For this, the set DHW
The extension kit for one heating circuit with mixer rQ regulates the temperature for reheating is reduced by boiler 1. Suppression
flow temperature of radiator heating circuit rP in weather-compensa- remains active for a certain time after solar circuit pump wE has been
ted mode. The boiler water temperature is raised by the differential switched off.
temperature set at control unit 2 of boiler 1. In the case of uninterrupted heating by collectors wP (> 2 h) boiler
Heating circuit pump M2 rR of radiator heating circuit rP is regulated 1 will only reheat, if the set cylinder temperature (coding address
by extension kit for one heating circuit with mixer rQ. "67") selected at boiler circuit control unit 2 is not achieved.
In control unit 2, coding address "67" defaults a third set DHW tem-
DHW heating by boiler perature (setting range 10 to 95 C). This value must be below the first
set DHW temperature.
Gas system boiler DHW cylinder qE will only be heated by boiler 1, if this set value
If the actual temperature falls below the DHW temperature set at con- cannot be achieved by the solar thermal system.
trol unit 2, the 3-way valve changes over to supply DHW cylinder
qE. The integral circulation pump is switched on.
5822 470 GB

System examples VIESMANN 31


Boiler wall mounted, 3.8 to 35 kW (cont.)

Hydraulic installation scheme ID: 4605132_1001_01

--KM-Bus--
--KM-Bus--
--24/6--

--2--
--6--
--5--
Vorlauf

41
21 24
20

--52--
--20--
--230V--
--24--
--22--
--230V--
Ruecklauf

40

22
43
--41/2--

44
--41/20--

23
---24/24--

3 --41/52--
45
WW

12 --x/x--
16

3
--2/X3--
-24/24-

15
--24/22--

17 --
--2/5-- 11 1

14
--24/5--
--KM-Bus--

--KM-Bus--

--KM-Bus--

KW 13
--X3--
--5--

2 4/ 5 7 6
--96--

--28--

--40--
--230V--

--40--
--A2--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
DHW circulation pump ZP qW is connected, subject to system equip-
ment, either to internal extension H1 4/ H2 5 or to extension AM1
6.

Equipment required

ID: 4605132_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit
3 Outside temperature sensor ATS
5822 470 GB

32 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

ID: 4605132_1001_01
Pos. Description Part no.
Room temperature controller/remote control
Constant temperature mode
uQ Vitotrol 100, type UTA 7170 149
or
uW Vitotrol 100, type UTDB Z007 691
or
Vitotrol 100, type UTDB-RF Z007 692
Weather-compensated mode
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
or
Vitohome 300 As per Viessmann pricelist
DHW heating via boiler 1
qQ Cylinder temperature sensor STS Connection set standard delivery
qW DHW circulation pump ZP As per Vitoset pricelist
DHW heating via solar thermal system wP
qE Dual mode DHW cylinder and connection set As per Viessmann pricelist
qQ Cylinder temperature sensor STS Connection set standard delivery
qR Cylinder temperature sensor SOL part of the standard delivery of pos. 3
24
qT High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wR Solar control module, type SM1 7429 073
wQ Collector temperature sensor KOL part of the standard delivery of pos.
24
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump Standard delivery, Solar-Divicon
qZ Automatic thermostatic mixing valve 7438 940
qU Circulation pump (transfer) on-site
wT Junction box on-site
Heating circuit with mixer rP
rQ Extension kit for one heating circuit with mixer with integral mixer motor rT 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor rT 7301 062
rE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
rR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Separate mixer motor As per Viessmann pricelist
Accessories (optional)
4 Internal extension H1 (standard delivery for the Vitodens 222-W/300-W/333-F and Vitoladens) 7179 057
5 Internal extension H2 7179 144
6 Extension AM1 7429 152
7 Extension EA1 7429 151
8 External extension H4 (Vitotrol 100, type UTDB uW for LV connection) 7197 227
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
Solar control module, type SM1 wR
uP Vitocom 100, type GSM As per Viessmann pricelist
5822 470 GB

or
zO Vitocom 200, type GP1 As per Viessmann pricelist

System examples VIESMANN 33


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ ZP 12 SLP
40 7 L

5
2
LON 69
2 L
96
5 STS 11 96 N
L
X3.7 P
X3.6 157 M 61
S N
3 X3.5
X3.4
Low voltage

N
28 M
X3.3 1~ ZP 12 SLP
67 L

X3.2
ATS 3 68
X3.1
3
2 145
1 3
145 2
KM BUS 65 66 70
1
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145 145 6
1 1

ID: 4605132_1001_01

Note
The cylinder primary pump (SLP) is integrated and fully wired with the
Vitodens 222-F, 222-W and 333-F (type FS3B).
5822 470 GB

34 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

6
7
N
40A 40
L
N
40A 40 41
L
N
A1
L
N
A2 M
1~ ZP 12
L
7
145 2 2
145
1 1

41
6
N
40A 40
L N
40A
L
40 24
3
N
M
20 1~ M2 44
L

N
52 M
1~ 45

2
2 1 VTS M2 43

2 2
145
1 1

24
41
N
40A 40
L
N
24 M
1~ 23
L
25
STB 15
N
22 M
1~ 17
L
2
PWM
1
4
6 KOL 21
3
2
5 SOL 14
1
2
1 145

ID: 4605132_1001_01
5822 470 GB

System examples VIESMANN 35


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.4 One heating circuit without and one heating circuit with mixer, with system separation
(optional sub-mounting/assembly kit)
Main components
Conventional gas boiler 1 Vitopend 200-W
or
Gas condensing boiler 1 Vitodens 200-W, 222-F, 222-W, 300-W,
333-F
or
Oil condensing boiler 1 Vitoladens 300-W, 333-F
Vitotronic 200 (for weather-compensated mode) 2
Plate heat exchanger Vitotrans 100 (system separation) rZ (part of
standard delivery for sub-mounting kit with mixer rU)
ID: 4605133_1001_01 Sub-mounting kit with mixer rU (only for the Vitopend 200-W,
Vitodens 200-W, 300-W)
or assembly kit with mixer rU (only for the Vitodens 222-F, 333-F)
Applications or
Separate heating circuit distributor
Heating system with two heating circuits: DHW heating by a solar thermal system (only with the Vitopend 200-
Unregulated radiator heating circuit eP W, Vitodens 200-W, 300-W and Vitoladens 300-W):
3 Regulated underfloor heating circuit rP Dual mode DHW cylinder qE
with 3-way mixer rT Solar thermal system wP
and system separation rZ for oxygen-permeable pipes (DIN 4726)
or Function description
with sub-mounting kit or assembly kit with mixer rU The circulation pump integrated into boiler 1 supplies either radiator
(contains 3-way mixer rT and system separation rZ) circuit eP and the primary circuit of plate heat exchanger (system sep-
aration) rZ, or DHW cylinder qE, via the integral 3-way valve.
DHW heating by the boiler and with a solar thermal system Heating circuit pump M2 rR supplies underfloor heating circuit rP.

Specification Heating mode


1. The flow rate (output) of radiator circuit eP is at least 30 % greater The 3-way valve is changed over to supply the heating circuits, and
than the flow rate of underfloor heating circuit rP. the integral circulation pump starts.
2. The total flow rate of both heating circuits eP/rP, less the bypass
volume of underfloor heating circuit rP, is less than the max. pos- Heating circuit without mixer
sible flow rate of boiler 1 (see table). Control unit 2 of boiler 1 regulates the boiler water temperature (=
flow temperature of heating circuit without mixer eP) in weather-com-
Boiler Max. flow rate pensated mode.
l/h
Vitopend 200-W, 10.5 to 18 kW and 10.5 1070 Heating circuit with mixer
to 24.0 kW The extension kit for one heating circuit with mixer rQ regulates the
Vitodens 200-W, 222-F, 222-W, 4.8 - 19.0 1200 flow temperature of underfloor heating circuit rP in weather-compen-
kW sated mode. The boiler water temperature is raised by the differential
Vitodens 200-W, 222-F, 222-W, 6.5 - 26.0 1400 temperature set at control unit 2 of boiler 1.
kW Heating circuit pump M2 rR of underfloor heating circuit rP is regula-
Vitodens 200-W, 222-F, 222-W, 8.8 - 35.0 1600 ted by extension kit for one heating circuit with mixer rQ (part of stand-
kW ard delivery for sub-mounting kit with mixer rU).
Vitodens 300-W, 333-F, 3.8 - 13.0 kW 1000 The maximum temperature of underfloor heating circuit rP is restricted
Vitodens 300-W, 333-F, 3.8 - 19.0 kW 1200 by temperature limiter rW.
Vitodens 300-W, 333-F, 5.2 - 26.0 kW 1400
Vitodens 300-W, 7.0 - 35.0 kW 1600 DHW heating by boiler
Vitoladens 300-W, 333-F, 12.9 - 23.5 kW 1390
Gas system boiler
If the actual temperature falls below the DHW temperature set at con-
Note
trol unit 2, the 3-way valve changes over to supply DHW cylinder
If the entire flow rate of both heating circuits eP/rP, less the bypass
qE. The integral circulation pump is switched on.
volume, is greater than the max. possible flow rate of boiler 1 (see
Within the periods selected at control unit 2, DHW heating has pri-
table), use a low loss header (see further sample applications).
ority.
Low loss headers are available in conjunction with Divicon or as indi-
DHW circulation pump ZP qW is connected, subject to system equip-
vidual accessories.
ment, either to internal extension H1 4/ H2 5 or to extension AM1
See Viessmann or Vitoset pricelists.
6.
Layout considerations of system separation rZ:
Gas combi boiler
The pressure drop on the secondary side of plate heat exchanger
In the case of DHW demand (draw-off), the 3-way valve is changed
rZ(system separation) must be the pressure drop of 3-way mixer
over to supply DHW (plate heat exchanger). The integral circulation
rT (mixer has control priority).
pump is switched on. The outlet temperature is regulated to the set
value.
5822 470 GB

The periods for the comfort function can be set at the time switch.

36 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Boiler with internal cylinder The requirements for the auxiliary function (see Vitosol technical
If the cylinder temperature sensor recognises a temperature lower guide) are met by circulation pump qU.
than the set default temperature, the 3-way valve is changed over to
supply the internal cylinder. The integral circulation pump is switched Suppression of reheating of the DHW cylinder by the boiler in
on. conjunction with solar control module (type SM1)
Heating stops when the set temperatures have been reached at the Reheating suppression takes place in two stages.
cylinder temperature sensor and at the outlet temperature sensor. The Reheating of DHW cylinder qE by boiler 1 is suppressed, as soon as
cylinder primary pump and 3-way valve remain on for a further 30s. DHW cylinder qE is heated by collectors wP. For this, the set DHW
temperature for reheating is reduced by boiler 1. Suppression
DHW heating by the solar thermal system remains active for a certain time after solar circuit pump wE has been
Solar circuit pump wE starts and DHW cylinder qE is heated up, if the switched off.
temperature differential between collector temperature sensor wQ and In the case of uninterrupted heating by collectors wP (> 2 h) boiler
cylinder temperature sensor qR exceeds the start temperature differ- 1 will only reheat, if the set cylinder temperature (coding address
ential. "67") selected at boiler circuit control unit 2 is not achieved.
In control unit 2, coding address "67" defaults a third set DHW tem-
Solar circuit pump wE stops if: perature (setting range 10 to 95 C). This value must be below the first
The actual temperature drops below the stop temperature differen- set DHW temperature.
tial DHW cylinder qE will only be heated by boiler 1, if this set value
The electronic temperature limit (max. 90C) of the solar control unit cannot be achieved by the solar thermal system.
(type SM1) wR is exceeded
The temperature selected at high limit safety cut-out (STB) qT (if
installed) is reached
3
5822 470 GB

System examples VIESMANN 37


Boiler wall mounted, 3.8 to 35 kW (cont.)

Hydraulic installation scheme ID: 4605133_1001_01

--KM-Bus--
--24/6--

--6--
--5--
Vorlauf

21 24
20

--24--
--22--
--230V--
Ruecklauf

30 40
42
22 --41/20--

--KM-Bus--
47
--41/2--

--2--
43
44 41
--41/20--

--52--
--20--
--230V--
45
--41/52--
23
---24/24-- 46

3
WW

12 --x/x--
16

3
--2/X3--
-24/24-

15
--24/22--

17 --
--2/5-- 11 1

14
--24/5--
--KM-Bus--

--KM-Bus--

--KM-Bus--

KW 13
--X3--
--5--

2 4 5 6 7
--A2--
--96--

--28--

--230V--
--230V--

--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
DHW circulation pump ZP qW is connected, subject to system equip-
ment, either to internal extension H1 4/ H2 5 or to extension AM1
6.
5822 470 GB

38 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Equipment required

ID: 4605133_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation
3 Outside temperature sensor ATS (only for weather-compensated mode)
4 Internal extension H1 (standard delivery for the Vitodens 222-F/222-W/300-W/333-F and Vitola- 7179 057
dens)
or
5 Internal extension H2 7179 144
or
6 Extension AM1 7429 152
7 Extension EA1 7429 151
DHW heating via boiler 1
qQ Cylinder temperature sensor STS Connection set standard delivery
qW DHW circulation pump ZP As per Vitoset pricelist
DHW heating via solar thermal system wP
qE Dual mode DHW cylinder and connection set As per Viessmann pricelist
qQ Cylinder temperature sensor STS Connection set standard delivery 3
qR Cylinder temperature sensor SOL part of the standard delivery of pos.
24
qT High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wR Solar control module, type SM1 7429 073
wQ Collector temperature sensor KOL part of the standard delivery of pos.
24
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump Standard delivery, Solar-Divicon
qZ Automatic thermostatic mixing valve 7438 940
qU Circulation pump (transfer) on-site
wT Junction box on-site
eP Heating circuit I
Heating circuit II rP
rQ Extension kit for one heating circuit with mixer with integral mixer motor rT 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor rT 7301 062
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
rR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Separate mixer motor As per Viessmann pricelist
rZ Plate heat exchanger Vitotrans 100 for system separation As per Viessmann pricelist
or
Heating circuit II rP with sub-mounting kit or assembly kit with mixer rU
rU Sub-mounting kit with mixer (for the Vitodens 200-W, 300-W and Vitopend 200-W) As per Viessmann pricelist
or
rU Assembly kit with mixer (for the Vitodens 222-F and 333-F) As per Viessmann pricelist
The sub-mounting kit or assembly kit with mixer
contains:
Mixer electronics rQ
Flow temperature sensor, heating circuit M2 rE
3-way mixer with mixer motor rT
Heating circuit pump, heating circuit M2 rR
Adjustable bypass
Plate heat exchanger for system separation rZ
rW Contact temperature limiter 7425 493
5822 470 GB

System examples VIESMANN 39


Boiler wall mounted, 3.8 to 35 kW (cont.)

ID: 4605133_1001_01
Pos. Description Part no.
Accessories (optional)
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
3 Solar control module, type SM1 wR
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist

5822 470 GB

40 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ ZP 12 SLP
40 7 L

5
2
LON 69
2 L
96
5 STS 11 96 N
L
X3.7 P
X3.6 157 M 61
S N
X3.5
X3.4 3
Low voltage

N
28 M
X3.3 1~ ZP 12 SLP
67 L

X3.2
ATS 3 68
X3.1
3
2 145
1 3
145 2
KM BUS 65 66 70
1
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145 145 6
1 1

ID: 4605133_1001_01

Note
The cylinder primary pump (SLP) is integrated and fully wired with the
Vitodens 222-F, 222-W and 333-F (type FS3B).
5822 470 GB

System examples VIESMANN 41


Boiler wall mounted, 3.8 to 35 kW (cont.)

6
7
N
40A 40
L
N
40A 40 41
L
N
A1
L
N
A2 M
1~ ZP 12
L
7
145 2 2
145
1 1

41
6
N
40A 40
L N
3 40A
L
40 24

42
N
M
20 1~ M2 44
L

N
52 M
1~ 45

2
2 1 VTS M2 43

2 2
145
1 1

24
41
N
40A 40
L
N
24 M
1~ 23
L
25
STB 15
N
22 M
1~ 17
L
2
PWM
1
4
6 KOL 21
3
2
5 SOL 14
1
2
1 145

ID: 4605133_1001_01
5822 470 GB

42 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.5 One heating circuit without mixer and one heating circuit with mixer with injection
control (control unit without auxiliary power, 3-way version)
The flow rate of underfloor heating circuit rP, which is subject to indi-
vidual design criteria, is balanced by an adjustable bypass.
The temperature of underfloor heating circuit rP is regulated via on-
site thermostatic mixer rE.
The maximum temperature of underfloor heating circuit rP is restricted
by temperature limiter rQ.

DHW heating by boiler

Gas system boiler


ID: 4605006_1001_03 If the actual temperature falls below the DHW temperature set at con-
trol unit 2, the 3-way valve changes over to supply DHW cylinder
qP. The integral circulation pump is switched on.
Applications Within the periods selected at control unit 2, DHW heating has pri-
ority.
Heating system with two heating circuits: DHW circulation pump ZP qW is connected, subject to system equip-
Unregulated radiator heating circuit eP ment, either to internal extension H1 4/ H2 5 or to extension AM1
Regulated underfloor heating circuit rP, injection control with con- 6.
3
troller without auxiliary power (3-way mixer rE)
Gas combi boiler
DHW heating by the Vitopend and with a solar thermal system In the case of DHW demand (draw-off), the 3-way valve is changed
over to supply DHW (plate heat exchanger). The integral circulation
Specification pump is switched on. The outlet temperature is regulated to the set
1. The flow rate (output) of radiator circuit eP is at least 30 % greater value.
than the flow rate of underfloor heating circuit rP. The periods for the comfort function can be set at the time switch.
2. The total flow rate of both heating circuits eP/rP, less the bypass
volume of underfloor heating circuit rP, is less than the max. pos- Boiler with internal cylinder
sible flow rate of boiler 1 of 1070 l/h. If the cylinder temperature sensor recognises a temperature lower
3. The pressure differential between radiator circuit eP and underfloor than the set default temperature, the 3-way valve is changed over to
heating circuit rP is balanced via butterfly regulating valves. supply the internal cylinder. The integral circulation pump is switched
on.
Note Heating stops when the set temperatures have been reached at the
If the total flow rate of both heating circuits eP/rP less bypass volume cylinder temperature sensor and at the outlet temperature sensor. The
exceeds 1070 l/h, use a low loss header and select a different appli- cylinder primary pump and 3-way valve remain on for a further 30s.
cation example.
Low loss headers are available in conjunction with Divicon or as indi- DHW heating by the solar thermal system
vidual accessories. Solar circuit pump wE starts and DHW cylinder qE is heated up, if the
See Viessmann or Vitoset pricelists. temperature differential between collector temperature sensor wQ and
cylinder temperature sensor qR exceeds the start temperature differ-
Main components ential.
Conventional gas boiler 1 Vitopend 200-W up to 24 kW
Vitotronic 200 (for weather-compensated mode) 2 Solar circuit pump wE stops if:
DHW heating with a solar thermal system The actual temperature drops below the stop temperature differen-
Dual mode DHW cylinder qE tial
Solar thermal system wP The electronic temperature limit (max. 90C) of the solar control unit
(type SM1) wR is exceeded
Function description The temperature selected at high limit safety cut-out (STB) qT (if
The circulation pump integrated into boiler 1 supplies either radiator installed) is reached
circuit eP or DHW cylinder qE via the integral 3-way valve.
Heating circuit pump rW supplies underfloor heating circuit rP. The requirements for the auxiliary function (see Vitosol technical
guide) are met by circulation pump qU.
Heating mode
The 3-way valve is changed over to supply the heating circuits, and Suppression of reheating of the DHW cylinder by the boiler in
the integral circulation pump starts. conjunction with solar control module (type SM1)
Reheating suppression takes place in two stages.
Heating circuit without mixer Reheating of DHW cylinder qE by boiler 1 is suppressed, as soon as
Control unit 2 of boiler 1 regulates the boiler water temperature (= DHW cylinder qE is heated by collectors wP. For this, the set DHW
flow temperature of heating circuit without mixer eP) in weather-com- temperature for reheating is reduced by boiler 1. Suppression
pensated mode. remains active for a certain time after solar circuit pump wE has been
switched off.
Heating circuit with mixer In the case of uninterrupted heating by collectors wP (> 2 h) boiler
Control unit 2 of boiler 1 regulates the boiler water temperature and 1 will only reheat, if the set cylinder temperature (coding address
the flow temperature of underfloor heating circuit rP in weather-com- "67") selected at boiler circuit control unit 2 is not achieved.
5822 470 GB

pensated mode. In control unit 2, coding address "67" defaults a third set DHW tem-
Heating circuit pump A1 rW of underfloor heating circuit rP is regulated perature (setting range 10 to 95 C). This value must be below the first
by internal extension H1 4/H2 5 or extension AM1 6. set DHW temperature.

System examples VIESMANN 43


Boiler wall mounted, 3.8 to 35 kW (cont.)

DHW cylinder qE will only be heated by boiler 1, if this set value


cannot be achieved by the solar thermal system.

Hydraulic installation scheme ID: 4605006_1001_03

--KM-Bus--
--24/6--

--6--
--5--
Vorlauf

21 24
20 --24--
--22--
--230V--

Ruecklauf

30 40
41
22 --x/x--

42
--x/x--
3
23
---24/24--
43

WW

12 --x/x--
16

3
--2/X3--
-24/24-

15
--24/22--

17 --
--2/5-- 11 1

14
--24/5--
--KM-Bus--

--KM-Bus--

--KM-Bus--

KW 13
--X3--
--5--

2 4 5 6 7
--96--

--28--

--A1--
--230V--

--230V--

--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
For the electrical connection x/x:
DHW circulation pump ZP qW and heating circuit pump A1 rW are
connected, subject to system equipment, either to internal extension
H1 4/ H2 5 or to extension AM1 6.
5822 470 GB

44 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Equipment required

ID: 4605006_1001_03
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation
3 Outside temperature sensor ATS (only for weather-compensated mode)
4 Internal extension H1 7179 057
or
5 Internal extension H2 7179 144
or
6 Extension AM1 7429 152
or
7 Extension EA1 7429 151
DHW heating via boiler 1
qQ Cylinder temperature sensor STS Connection set standard delivery
qW DHW circulation pump ZP As per Vitoset pricelist
DHW heating via solar thermal system wP
qE Dual mode DHW cylinder and connection set As per Viessmann pricelist
qQ Cylinder temperature sensor STS Connection set standard delivery 3
qR Cylinder temperature sensor SOL part of the standard delivery of pos.
24
qT High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wR Solar control module, type SM1 7429 073
wQ Collector temperature sensor KOL part of the standard delivery of pos.
24
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump Standard delivery, Solar-Divicon
qZ Automatic thermostatic mixing valve 7438 940
qU Circulation pump (transfer) on-site
wT Junction box on-site
eP Heating circuit I
rP Heating circuit II
rQ Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rW Heating circuit pump see Vitoset pricelist
rE Controller without auxiliary power on-site
Accessories (optional)
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension AM1 6
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
Solar control module, type SM1 wR
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
5822 470 GB

System examples VIESMANN 45


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ ZP 12 A1 42 41
40 7 L

5
2
LON 69
2 L
96
5 STS 11 96 N
L
X3.7 P
X3.6 157 M 61
S N
3 X3.5
X3.4
Low voltage

N
28 M A1 42 41
X3.3 1~ ZP 12
67 L

X3.2
ATS 3 68
X3.1
3
2 145
1 3
145 2
KM BUS 65 66 70
1
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2 145 6
145
1 1

ID: 4605006_1001_03
5822 470 GB

46 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

6
7
N
40A 40
L
N
40A 40 24
L

41
N
M A1 42
A1 1~
L

N
A2 M
1~ ZP 12
L
7
145 2 2
145
1 1

24
6
N 3
40A 40
L
N
24 M
1~ 23
L
25
STB 15
N
22 M
1~ 17
L
2
PWM
1
4
6 KOL 21
3
2
5 SOL 14
1
2
1 145

ID: 4605006_1001_03
5822 470 GB

System examples VIESMANN 47


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.6 One heating circuit without mixer with separate heating circuit pump and two heating
circuits with mixer, with low loss header
Function description
The circulation pump integrated into boiler 1 supplies the boiler circuit
up to low loss header tP or DHW cylinder qE via the integral 3-way
valve.
Heating circuit pump A1 eQ supplies radiator circuit eP.
Heating circuit pump M2 rR supplies underfloor heating circuit rP.
Heating circuit pump M3 iR supplies radiator circuit iP.

Heating mode
The 3-way valve is changed over to supply the heating circuits, and
ID: 4605134_1001_01 the integral circulation pump starts.

Heating circuit without mixer


Applications Control unit 2 of boiler 1 regulates the boiler water temperature (=
flow temperature of heating circuit without mixer eP) in weather-com-
Heating system with three heating circuits: pensated mode.
Unregulated radiator heating circuit eP Heating circuit pump A1 eQ of radiator heating circuit eP is regulated
3 with heating circuit pump A1 eQ by internal extension H1 4/H2 5 or extension AM1 6.
Regulated underfloor heating circuit rP
with 3-way mixer rT Heating circuits with mixer
Regulated radiator heating circuit iP Extension kit for one heating circuit with mixer rQ/iQ regulates the
with 3-way mixer iT flow temperature of underfloor heating circuit rP or radiator heating
and low loss header tP circuit iP in weather-compensated mode. The boiler water tempera-
ture is raised by the differential temperature set at control unit 2 of
DHW heating by the boiler and the solar thermal system boiler 1.
Heating circuit pump M2 rR of underfloor heating circuit rP is regula-
Specification ted by extension kit for one heating circuit with mixer rQ.
1. Use of the heating circuit pump A1 eQ in radiator heating circuit eP Heating circuit pump M3 iR of radiator heating circuit iP is regulated
The flow rate (output) of radiator circuit eP is greater than 30 % of by extension kit for one heating circuit with mixer iQ.
the flow rate of underfloor heating circuit rP. The maximum temperature of underfloor heating circuit rP is restricted
2. Using low loss header tP and heating circuit pump A1 eQ in radiator by temperature limiter rW.
circuit eP: The flow rate of underfloor heating circuit rP, which is subject to indi-
The total flow rate of both heating circuits, less the bypass volume vidual design criteria, is balanced by an adjustable bypass.
of underfloor heating circuit rP, is greater than the max. possible
flow rate of boiler 1 (see table). DHW heating by boiler

Boiler Max. flow rate Gas system boiler


l/h If the actual temperature falls below the DHW temperature set at con-
Vitopend 200-W, 10.5 to 18 kW and 10.5 1070 trol unit 2, the 3-way valve changes over to supply DHW cylinder
to 24.0 kW qE. The integral circulation pump is switched on.
Vitodens 200-W, 222-F, 222-W, 4.8 - 19.0 1200 Within the periods selected at control unit 2, DHW heating has pri-
kW ority.
Vitodens 200-W, 222-F, 222-W, 6.5 - 26.0 1400 DHW circulation pump ZP qW is connected, subject to system equip-
kW ment, either to internal extension H1 4/ H2 5 or to extension AM1
Vitodens 200-W, 222-F, 222-W, 8.8 - 35.0 1600 6.
kW
Vitodens 300-W, 333-F, 3.8 - 13.0 kW 1000 Gas combi boiler
Vitodens 300-W, 333-F, 3.8 - 19.0 kW 1200 In the case of DHW demand (draw-off), the 3-way valve is changed
Vitodens 300-W, 333-F, 5.2 - 26.0 kW 1400 over to supply DHW (plate heat exchanger). The integral circulation
Vitodens 300-W, 7.0 - 35.0 kW 1600 pump is switched on. The outlet temperature is regulated to the set
value.
Vitoladens 300-W, 333-F, 12.9 - 23.5 kW 1390
The periods for the comfort function can be set at the time switch.
Main components
Boiler with internal cylinder
Conventional gas boiler 1 Vitopend 200-W
If the cylinder temperature sensor recognises a temperature lower
or
than the set default temperature, the 3-way valve is changed over to
Gas condensing boiler 1 Vitodens 200-W, 222-F, 222-W, 300-W,
supply the internal cylinder. The integral circulation pump is switched
333-F
on.
or
Heating stops when the set temperatures have been reached at the
Oil condensing boiler 1 Vitoladens 300-W, 333-F
cylinder temperature sensor and at the outlet temperature sensor. The
Vitotronic 200 (for weather-compensated mode) 2
cylinder primary pump and 3-way valve remain on for a further 30s.
Low loss header tP
DHW heating by a solar thermal system (only with the Vitopend 200-
DHW heating by the solar thermal system
W, Vitodens 200-W, 300-W and Vitoladens 300-W):
5822 470 GB

Solar circuit pump wE starts and DHW cylinder qE is heated up, if the
Dual mode DHW cylinder qE
temperature differential between collector temperature sensor wQ and
Solar thermal system wP
cylinder temperature sensor qR exceeds the start temperature differ-
ential.

48 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Solar circuit pump wE stops if: Reheating of DHW cylinder qE by boiler 1 is suppressed, as soon as
The actual temperature drops below the stop temperature differen- DHW cylinder qE is heated by collectors wP. For this, the set DHW
tial temperature for reheating is reduced by boiler 1. Suppression
The electronic temperature limit (max. 90C) of the solar control unit remains active for a certain time after solar circuit pump wE has been
(type SM1) wR is exceeded switched off.
The temperature selected at high limit safety cut-out (STB) qT (if In the case of uninterrupted heating by collectors wP (> 2 h) boiler
installed) is reached 1 will only reheat, if the set cylinder temperature (coding address
"67") selected at boiler circuit control unit 2 is not achieved.
The requirements for the auxiliary function (see Vitosol technical In control unit 2, coding address "67" defaults a third set DHW tem-
guide) are met by circulation pump qU. perature (setting range 10 to 95 C). This value must be below the first
set DHW temperature.
Suppression of reheating of the DHW cylinder by the boiler in DHW cylinder qE will only be heated by boiler 1, if this set value
conjunction with solar control module (type SM1) cannot be achieved by the solar thermal system.
Reheating suppression takes place in two stages.

Hydraulic installation scheme ID: 4605134_1001_01

--KM-Bus--

--KM-Bus--
--KM-Bus--
--24/6--

--2--
3

--2--
--6--
--5--

Vorlauf

81 41
21 24
20

--52--
--20--

--52--
--20--
--230V--

--230V--
--24--
--22--
--230V--

Ruecklauf

30 80 40
42
22 --41/20--
83 43
-81/2- --41/2--

84 44
31 -81/20- --41/20--
--x/x--

23 -81/52- --41/52--
----24/24--
85 45

51
WW --2/X3--

12 --x/x--
16 50

--2/X3--
-24/24-

3
15
--24/22--

17 --
--2/5-- 11
1
14
--24/5--
--KM-Bus--

--KM-Bus--

--KM-Bus--

KW 13
--X3--
--5--

2 4/5 6 7
--96--

--28--

--A1--
--230V--

--230V--

--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
5822 470 GB

System examples VIESMANN 49


Boiler wall mounted, 3.8 to 35 kW (cont.)

Note
Diagram with low loss header tP applies only to gas system boilers.
For the electrical connection x/x:
DHW circulation pump ZP qW and heating circuit pump A1 eQ are
connected, subject to system equipment, either to internal extension
H1 4/ H2 5 or to extension AM1 6.

Equipment required

ID: 4605134_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation
3 Outside temperature sensor ATS (only for weather-compensated mode)
System without DHW circulation
4 Internal extension H1 (standard delivery for the Vitodens 222-F/222-W/300-W/333-F and Vitola- 7179 057
dens)
or
5 Internal extension H2 7179 144
3 or
System with DHW circulation
6 Extension AM1 7429 152
7 Extension EA1 7429 151
DHW heating via boiler 1
qQ Cylinder temperature sensor STS Connection set standard delivery
qW DHW circulation pump ZP As per Vitoset pricelist
DHW heating via solar thermal system wP
qE Dual mode DHW cylinder and connection set As per Viessmann pricelist
qQ Cylinder temperature sensor STS Connection set standard delivery
qR Cylinder temperature sensor SOL part of the standard delivery of pos.
24
qT High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wR Solar control module, type SM1 7429 073
wQ Collector temperature sensor KOL part of the standard delivery of pos.
24
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump Standard delivery, Solar-Divicon
qZ Automatic thermostatic mixing valve 7438 940
qU Circulation pump on-site
wT Junction box on-site
eP Heating circuit I
eQ Heating circuit pump, heating circuit A1 on-site
or
Divicon As per Viessmann pricelist
Heating circuit II rP
rQ Extension kit for one heating circuit with mixer with integral mixer motor rT 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor rT 7301 062
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
rR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Separate mixer motor As per Viessmann pricelist
5822 470 GB

50 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

ID: 4605134_1001_01
Pos. Description Part no.
Heating circuit III iP
iQ Extension kit for one heating circuit with mixer with integral mixer motor iT 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor iT 7301 062
iE Flow temperature sensor, heating circuit M3 Standard delivery, extension kit
iR Heating circuit pump, heating circuit M3 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
iT Separate mixer motor As per Viessmann pricelist
Low loss header tP
tP Low loss header in conjunction with Divicon As per Viessmann pricelist
or
Low loss header As per Vitoset pricelist
tQ Flow temperature sensor for low loss header 7179 488
Accessories (optional)
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site 3
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension AM1 6
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
Solar control module, type SM1 wR
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
5822 470 GB

System examples VIESMANN 51


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ ZP 12 A1 31 SLP
40 7 L

5
2
LON 69
2 L
96
5 STS 11 96 N
L
X3.7 P
X3.6 157 M 61
S N
3 X3.5
X3.4
VTS 51
Low voltage

N
28 M A1 31 SLP
X3.3 1~ ZP 12
67 L

X3.2
ATS 3 68
X3.1
3
2 145
1 3
145 2
KM BUS 65 66 70
1
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145
1 1

6
7
N
40A 40
L
N
40A 40 41
L
N
A1 M A1
1~ 31
L
N
A2 M
1~ ZP 12
L

2 2 145 41
145
1 1

ID: 4605134_1001_01
5822 470 GB

Note
The cylinder primary pump (SLP) is integrated and fully wired with the
Vitodens 222-F, 222-W and 333-F (type FS3B).

52 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

41
6
N
40A 40
L N
40A 40 81
L
42
N
M
20 1~ M2 44
L

N
52 M
1~ 45

2
2 1 VTS M2 43

6
145 2 2
145
1 1

3
81
41
N
40A 40
L N
40A 40 24
L

N
M
20 1~ M3 84
L
N
52 M
1~ 85

2
2 1 VTS M3 83

2 2
145
1 1

24
81
N
40A 40
L
N
24 M
1~ 23
L
25
STB 15
N
22 M
1~ 17
L
2
PWM
1
4
6 KOL 21
3
2
5 SOL 14
1
2
1 145

ID: 4605134_1001_01
5822 470 GB

System examples VIESMANN 53


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.7 One heating circuit without mixer


Heating circuit without mixer
Control unit 2 of boiler 1 regulates the boiler water temperature (=
flow temperature of heating circuit without mixer eP) in weather-com-
pensated mode.

DHW heating
The internal solar circuit pump is switched on and the DHW cylinder is
heated up if the temperature differential between collector temperature
sensor wQ and the Vitodens integral cylinder temperature sensor
exceeds the start temperature differential.
The DHW cylinder is additionally heated by the Vitodens if the output
ID: 4605135_1001_01
of the solar circuit is inadequate for the set DHW temperature to be
reached. The 3-way valve is changed over to supply the DHW cylinder.
Applications The integral circulation pump is switched on.
Within the periods selected at control unit 2, DHW heating has pri-
Heating system with one heating circuit: ority.
Unregulated radiator heating circuit eP DHW circulation pump ZP qW is connected to extension AM1 6.
DHW heating with solar energy using the integral DHW cylinder
3 Suppression of reheating of the DHW cylinder by the boiler in
Main components conjunction with solar control module (type SM1)
Gas condensing boiler 1 Vitodens 343-F Reheating suppression takes place in two stages.
Vitotronic 200 (for weather-compensated mode) Reheating of the DHW cylinder by boiler 1 is suppressed, as soon
Solar thermal system wP as the DHW cylinder is heated by collectors wP. For this, the set DHW
temperature for reheating is reduced by boiler 1. Suppression
Function description remains active for a certain time after the solar circuit pump has been
The circulation pump integrated into boiler 1 supplies either heating switched off.
circuit eP or the integral plate heat exchanger via the integral 3-way In the case of uninterrupted heating by collectors wP (> 2 h) boiler
valve. 1 will only reheat, if the set cylinder temperature (coding address
An additional internal circulation pump supplies the DHW cylinder with "67") selected at boiler circuit control unit 2 is not achieved.
solar backup and the solar circuit. In control unit 2, coding address "67" defaults a third set DHW tem-
The solar circuit is regulated by the integral solar control module. perature (setting range 10 to 95 C). This value must be below the first
set DHW temperature.
Heating mode The DHW cylinder will only be heated by boiler 1, if this set value
The 3-way diverter valve is changed over to supply the heating circuit, cannot be achieved by the solar thermal system.
and the integral circulation pump starts.

5822 470 GB

54 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Hydraulic installation scheme ID: 4605135_1001_01


--8/6--

Vorlauf

21
20 30
Ruecklauf

WW
3
3
--2/X3--

--6/A2--
12

KW

1
--KM-Bus--

--KM-Bus--

--KM-Bus--
--X3--
--6--

2 4 / 5 8 9 7 6
--96--

--28--

--40--
--40A--
--230V--

--40--
--A1--
--A2--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605135_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation with solar control module
3 Outside temperature sensor ATS
4 Internal extension H1
8 Integral solar control module
9 Terminal box
DHW heating
qW DHW circulation pump ZP As per Vitoset pricelist
Solar thermal system wP
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL Standard delivery for the Vitodens
Heating circuit without mixer eP
5822 470 GB

System examples VIESMANN 55


Boiler wall mounted, 3.8 to 35 kW (cont.)

ID: 4605135_1001_01
Pos. Description Part no.
Accessories
5 Internal extension H2 7179 144
6 Extension AM1 7429 152
7 Extension EA1 7429 151
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension EA1 7
3 Extension AM1 6
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist

5822 470 GB

56 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M SLP
1~
40 7 L

5
2
LON 69
2 L
96
5 96 N
L
P
X3.9
157 M 61
X3.8
S N
X3.7
X3.6
3
N
28 M SLP
X3.5 1~
X3.4 L
Low voltage

X3.3
67 68

X3.2 3
ATS 3 2 145
X3.1
1 3
145 2
KM BUS 65 66 70
1
8
9 3
145 2
6 KOL 21 1

2 N
40
96 L
N
40A
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145
1 1

6
7
N
40A 40
L
N
40A
L
N
A1
L
N
A2 M
1~ ZP 12
L

2 2
145
1 1

ID: 4605135_1001_01
5822 470 GB

System examples VIESMANN 57


Boiler wall mounted, 3.8 to 35 kW (cont.)

Note
The cylinder primary pump (SLP) on the Vitodens 343-F is integrated
and fully wired.

5822 470 GB

58 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.8 Two heating circuits with mixer and with low loss header
Heating circuit with mixer
Extension kit for the heating circuit with mixer rQ/iQ regulates the flow
temperature of underfloor heating circuit rP or radiator heating circuit
iP in weather-compensated mode.
The boiler water temperature is raised by the differential temperature
set at control unit 2 of boiler 1.
Heating circuit pump rR/iR of underfloor heating circuit rP or radiator
heating circuit iP is regulated by extension kit for one heating circuit
with mixer rQ/iQ.
The flow rate of underfloor heating circuit rP (without system separa-
ID: 4605136_1001_01 tion), which is subject to individual design criteria, is balanced by an
adjustable bypass.
The maximum temperature of underfloor heating circuit rP is restricted
Applications by temperature limiter rW.

Heating system with one heating circuit: DHW heating


Regulated radiator heating circuit iP The internal solar circuit pump is switched on and the DHW cylinder is
Regulated underfloor heating circuit rP heated up if the temperature differential between collector temperature
DHW heating with solar energy using the integral DHW cylinder sensor wQ and the Vitodens integral cylinder temperature sensor 3
exceeds the start temperature differential.
Main components The DHW cylinder is additionally heated by the Vitodens if the output
Gas condensing boiler 1 Vitodens 343-F of the solar circuit is inadequate for the set DHW temperature to be
Vitotronic 200 (for weather-compensated mode) reached. The 3-way valve is changed over to supply the DHW cylinder.
Solar thermal system wP The integral circulation pump is switched on.
Within the periods selected at control unit 2, DHW heating has pri-
Specification ority.
The flow rate (output) of underfloor heating circuit rP is greater than DHW circulation pump ZP qW is connected to extension AM1 6.
the max. possible flow rate of 1000 l/h of the Vitodens.
Therefore, a low loss header tP must be installed. Suppression of reheating of the DHW cylinder by the boiler in
Low loss headers are available in conjunction with Divicon or as indi- conjunction with solar control module (type SM1)
vidual accessories. Reheating suppression takes place in two stages.
See Viessmann or Vitoset pricelist. Reheating of the DHW cylinder by boiler 1 is suppressed, as soon
as the DHW cylinder is heated by collectors wP. For this, the set DHW
Function description temperature for reheating is reduced by boiler 1. Suppression
The circulation pump integrated into boiler 1 supplies either the pri- remains active for a certain time after the solar circuit pump has been
mary circuit up to low loss header tP, or the internal plate heat switched off.
exchanger via the integral 3-way valve. In the case of uninterrupted heating by collectors wP (> 2 h) boiler
An additional internal circulation pump supplies the DHW cylinder with 1 will only reheat, if the set cylinder temperature (coding address
solar backup and the solar circuit. "67") selected at boiler circuit control unit 2 is not achieved.
The solar circuit is regulated by the integral solar control module. In control unit 2, coding address "67" defaults a third set DHW tem-
For one heating circuit with mixer, heating circuit pump M2 rR supplies perature (setting range 10 to 95 C). This value must be below the first
underfloor heating circuit rP. set DHW temperature.
The DHW cylinder will only be heated by boiler 1, if this set value
Heating mode cannot be achieved by the solar thermal system.
The 3-way diverter valve is changed over to supply the heating circuit,
and the integral circulation pump starts.
5822 470 GB

System examples VIESMANN 59


Boiler wall mounted, 3.8 to 35 kW (cont.)

Hydraulic installation scheme ID: 4605136_1001_01


--8/6--

80
Vorlauf

40
21 42
20
--41/20--
Ruecklauf
83 43
--81/2-- --41/2--

84 44
--81/20-- --41/20--
85 45
--81/52-- --41/52--

--2/X3-- 51

50

--KM-Bus--

--KM-Bus--
3

--2--
WW

--2--
3
81 41
--2/X3--

--6/A2--

--52--
--20--
--230V--

--52--
--20--
--230V--
12

KW

1
--KM-Bus--

--KM-Bus--

--KM-Bus--
--X3--
--6--

2 4 / 5 8 9 7 6
--96--

--28--

--40--

--40--
--A1--
--40A--

--A2--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605136_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation with solar control module
3 Outside temperature sensor ATS
4 Internal extension H1
8 Integral solar control module
9 Terminal box
DHW heating
qW DHW circulation pump ZP As per Vitoset pricelist
5822 470 GB

60 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

ID: 4605136_1001_01
Pos. Description Part no.
Solar thermal system wP
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL Standard delivery for the Vitodens
Heating circuit I with mixer rP
rQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
rR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Separate mixer motor As per Viessmann pricelist
Heating circuit II with mixer iP 3
iQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
iE Flow temperature sensor, heating circuit M3 Standard delivery, extension kit
iR Heating circuit pump, heating circuit M3 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
iT Separate mixer motor As per Viessmann pricelist
Low loss header tP
tP Low loss header (in conjunction with Divicon heating circuit distributor) As per Viessmann pricelist
tQ Flow temperature sensor for low loss header 7179 488
Accessories
5 Internal extension H2 7179 144
6 Extension AM1 7429 152
7 Extension EA1 7429 151
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires external extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension EA1 7
Extension AM1 6
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
5822 470 GB

System examples VIESMANN 61


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M SLP
1~
40 7 L

5
2
LON 69
2 L
96
5 96 N
L
P
X3.9
157 M 61
X3.8
S N
3 X3.7
X3.6
N
28 M SLP
X3.5 VTS 1~
51 L
X3.4
Low voltage

X3.3
67 68

X3.2 3
ATS 3 2 145
X3.1
1 3
145 2
KM BUS 65 66 70
1
8
9 3
145 2
6 KOL 21 1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145
1 1

6
7
N
40A 40
L
N
40A 40 41
L
N
A1
L
N
A2 M
1~ ZP 12
L

2 2 145 41
145
1 1

ID: 4605136_1001_01
5822 470 GB

62 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Note
The cylinder primary pump (SLP) on the Vitodens 343-F is integrated
and fully wired.

41
6
N
40A 40
L N
40A 40 81
L
42
N
M
20 1~ M2 44
L

N
52 M
1~ 45

2
2 VTS M2 43

6
1
3
145 2 2
145
1 1

81
41
N
40A 40
L N
40A
L

N
M
20 1~ M3 84
L
N
52 M
1~ 85

2
2 1 VTS M3 83

2 2
145
1 1

ID: 4605136_1001_01
5822 470 GB

System examples VIESMANN 63


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.9 One heating circuit without mixer and one heating circuit with mixer, without or with
system separation
Heating circuit pump M2 rR supplies underfloor heating circuit rP.

Heating mode
The 3-way valve is changed over to supply the heating circuits, and
the integral circulation pump starts.

Heating circuit without mixer


Control unit 2 of boiler 1 regulates the boiler water temperature (=
flow temperature of heating circuit without mixer eP) in weather-com-
pensated mode.
ID: 4605137_1001_01
Heating circuit with mixer
The extension kit for one heating circuit with mixer rQ regulates the
Applications flow temperature of underfloor heating circuit rP in weather-compen-
sated mode.
Heating system with one unregulated radiator heating circuit eP and: The boiler water temperature is raised by the differential temperature
regulated underfloor heating circuit rP set at control unit 2 of boiler 1.
3 with 3-way mixer rT Heating circuit pump M2 rR of underfloor heating circuit rP is regula-
and system separation rU for oxygen-permeable pipes (DIN 4726) ted by extension kit for one heating circuit with mixer rQ.
DHW heating with solar energy using the integral DHW cylinder The maximum temperature of underfloor heating circuit rP is restricted
by temperature limiter rW.
Specification
1. The flow rate (output) of radiator circuit eP is at least 30 % greater DHW heating
than the flow rate of underfloor heating circuit rP. The internal solar circuit pump is switched on and the DHW cylinder is
2. The total flow rate of both heating circuits eP/rP less bypass volume heated up if the temperature differential between collector temperature
of underfloor heating circuit rP is less than the max. possible flow sensor wQ and the Vitodens integral cylinder temperature sensor
rate of 1000 l/h of the Vitodens. exceeds the start temperature differential.
The DHW cylinder is additionally heated by the Vitodens if the output
Note of the solar circuit is inadequate for the set DHW temperature to be
If the total flow rate of both heating circuits eP/rP less the bypass reached. The 3-way valve is changed over to supply the DHW cylinder.
volume is greater than the maximum possible flow rate of the Vitodens, The integral circulation pump is switched on.
use a low loss header (see further sample applications). Within the periods selected at control unit 2, DHW heating has pri-
ority.
Layout considerations of system separation rU: DHW circulation pump ZP qW is connected to extension AM1 6.
The pressure drop on the secondary side of plate heat exchanger
rU(system separation) must be the pressure drop of 3-way mixer Suppression of reheating of the DHW cylinder by the boiler in
rT (mixer has control priority). conjunction with solar control module (type SM1)
Reheating suppression takes place in two stages.
Main components Reheating of the DHW cylinder by boiler 1 is suppressed, as soon
Gas condensing boiler 1 Vitodens 343-F as the DHW cylinder is heated by collectors wP. For this, the set DHW
Vitotronic 200 (for weather-compensated mode) temperature for reheating is reduced by boiler 1. Suppression
Plate heat exchanger Vitotrans 100 (system separation) rU remains active for a certain time after the solar circuit pump has been
Solar thermal system wP switched off.
In the case of uninterrupted heating by collectors wP (> 2 h) boiler
Function description 1 will only reheat, if the set cylinder temperature (coding address
The circulation pump integrated into boiler 1 supplies either radiator "67") selected at boiler circuit control unit 2 is not achieved.
circuit eP and underfloor heating circuit rP or the primary circuit of In control unit 2, coding address "67" defaults a third set DHW tem-
plate heat exchanger (system separation) rU, or the internal plate heat perature (setting range 10 to 95 C). This value must be below the first
exchanger via the integral 3-way valve. set DHW temperature.
An additional internal circulation pump supplies the DHW cylinder with The DHW cylinder will only be heated by boiler 1, if this set value
solar backup and the solar circuit. cannot be achieved by the solar thermal system.
The solar circuit is regulated by the integral solar control module.
5822 470 GB

64 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Hydraulic installation scheme ID: 4605137_1001_01

30 40
--8/6--

42

-KM-Bus--
Vorlauf
--41/20--

--2--
21
20 --41/2--
43 41

--52--
--20--
--230V--
44
Ruecklauf

--41/20--

--41/52--
45 47

3
WW
3
--2/X3--

--6/A2--
12

KW

1
--KM-Bus--

--KM-Bus--

--KM-Bus--
--X3--
--6--

2 4 / 5 8 9 7 6
--96--

--28--

--40--

--40A--

--40--
--A1--
--A2--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605137_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation with solar control module
3 Outside temperature sensor ATS
4 Internal extension H1
8 Integral solar control module
9 Terminal box
DHW heating
qW DHW circulation pump ZP As per Vitoset pricelist
Solar thermal system wP
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL Standard delivery for the Vitodens
eP Heating circuit I
5822 470 GB

System examples VIESMANN 65


Boiler wall mounted, 3.8 to 35 kW (cont.)

ID: 4605137_1001_01
Pos. Description Part no.
Heating circuit II rP
rQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
rR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Separate mixer motor As per Viessmann pricelist
System separation rU
rU Plate heat exchanger Vitotrans 100 As per Viessmann pricelist
Accessories
3 5 Internal extension H2 7179 144
6 Extension AM1 7429 152
7 Extension EA1 7429 151
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension EA1 7
Extension AM1 6
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist

5822 470 GB

66 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M SLP
1~
40 7 L

5
2
LON 69
2 L
96
5 96 N
L
P
X3.9
157 M 61
X3.8
S N
X3.7
X3.6
N
3
28 M SLP
X3.5 1~
X3.4 L
Low voltage

X3.3
67 68

X3.2 3
ATS 3 2 145
X3.1
1 3
145 2
KM BUS 65 66 70
1
8
9 3
145 2
6 KOL 21 1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145
1 1

6
7
N
40A 40
L
N 40 41
40A
L
N
A1
L
N
A2 M
1~ ZP 12
L

2 2 145 41
145
1 1

ID: 4605137_1001_01
5822 470 GB

System examples VIESMANN 67


Boiler wall mounted, 3.8 to 35 kW (cont.)

Note
The cylinder primary pump (SLP) on the Vitodens 343-F is integrated
and fully wired.

41
6
N
40A 40
L N
40A
L
42
N
M
20 1~ M2 44
L

N
52 M
1~ 45

2
2 1 VTS M2 43

3 6
145 2 2
145
1 1

ID: 4605137_1001_01

5822 470 GB

68 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

3.10 Two heating circuits with mixer and low loss header, without or with system sepa-
ration
Heating circuits with mixer
Extension kit for one heating circuit with mixer rQ/eQ regulates the
flow temperature of underfloor heating circuit rP or the flow tempera-
ture of radiator heating circuit eP in weather-compensated mode.
The boiler water temperature is regulated according to the highest
demand (increased flow temperature by an adjustable differential tem-
perature).
Heating circuit pump M2 eR is regulated by extension kit eQ.
Heating circuit pump M3 rR and circulation pump rT of underfloor
heating circuit rP are regulated by extension kit for one heating circuit
ID: 4605138_1001_01 with mixer rQ (both pumps connected in parallel).
The maximum temperature of underfloor heating circuit rP is restricted
by temperature limiter rW.
Applications
DHW heating
Heating system with low loss header, a regulated radiator circuit eP The internal solar circuit pump is switched on and the DHW cylinder is
and: heated if the temperature differential between collector temperature
regulated underfloor heating circuit rP sensor wQ and the integral cylinder temperature sensor of the Vitodens
3
with 3-way mixer rT exceeds the start temperature differential.
and system separation rU for oxygen-permeable pipes (DIN 4726) The DHW cylinder is additionally heated by the Vitodens if the output
DHW heating with solar energy using the integral DHW cylinder of the solar circuit is inadequate for the set DHW temperature to be
reached. The 3-way valve is changed over to supply the DHW cylinder.
Specification The integral circulation pump is switched on.
The total flow rate of both heating circuits less bypass volume of Within the periods selected at control unit 2, DHW heating has pri-
underfloor heating circuit rP is less than the max. possible flow rate of ority.
1000 l/h of the Vitodens, therefore, a low loss header tP must be DHW circulation pump ZP qW is connected to extension AM1 6.
installed.
Suppression of reheating of the DHW cylinder by the boiler in
Main components conjunction with solar control module (type SM1)
Gas condensing boiler 1 Vitodens 343-F Reheating suppression takes place in two stages.
Vitotronic 200 (for weather-compensated mode) Reheating of the DHW cylinder by boiler 1 is suppressed, as soon
Low loss header tP as the DHW cylinder is heated by collectors wP. For this, the set DHW
Plate heat exchanger Vitotrans 100 (system separation) rU temperature for reheating is reduced by boiler 1. Suppression
Solar thermal system wP remains active for a certain time after the solar circuit pump has been
switched off.
Function description In the case of uninterrupted heating by collectors wP (> 2 h) boiler
The circulation pump integrated into boiler 1 supplies the boiler circuit 1 will only reheat, if the set cylinder temperature (coding address
up to the low loss header, or the internal plate heat exchanger via the "67") selected at boiler circuit control unit 2 is not achieved.
integral 3-way valve. In control unit 2, coding address "67" defaults a third set DHW tem-
An additional internal circulation pump supplies the DHW cylinder with perature (setting range 10 to 95 C). This value must be below the first
solar backup and the solar circuit. set DHW temperature.
The solar circuit is regulated by the integral solar control module. The DHW cylinder will only be heated by boiler 1, if this set value
Heating circuit pump M2 eW supplies radiator circuit eP. cannot be achieved by the solar thermal system.
Heating circuit pump M3 rR supplies underfloor heating circuit rP.
Circulation pump M3 rT supplies the primary circuit of plate heat
exchanger (system separation) rU.

Heating mode
The 3-way valve is changed over to supply the heating circuits, and
the integral circulation pump starts.
5822 470 GB

System examples VIESMANN 69


Boiler wall mounted, 3.8 to 35 kW (cont.)

Hydraulic installation scheme ID: 4605138_1001_01

30 40
--8/6--

42
Vorlauf
--41/20--
33 43
21 --31/2--
20 --41/2--

44
34
Ruecklauf

--41/20--
--31/20--
47

--31/52--
36 45
--41/20--

51 --41/52--
--2/X3-- 46

50

--KM-Bus--
--KM-Bus--
3
WW

--2--
--2--
3
31 41
--2/X3--

--6/A2--

--52--
--20--
--20--
--52--

--230V--
--230V--
12

KW

1
--KM-Bus--

--KM-Bus--

--KM-Bus--
--X3--
--6--

2 4 / 5 8 9 7 6
--96--

--28--

--40--
--40A--

--40--
--A1--
--230V--

--A2--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605138_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation with solar control module
3 Outside temperature sensor ATS
4 Internal extension H1
8 Integral solar control module
9 Terminal box
DHW heating
qW DHW circulation pump ZP As per Vitoset pricelist
5822 470 GB

70 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

ID: 4605138_1001_01
Pos. Description Part no.
Solar thermal system wP
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL Standard delivery for the Vitodens
Heating circuit I eP
eQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
eE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
eR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
eZ Separate mixer motor As per Viessmann pricelist
Heating circuit II rP
rQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems 3
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit M3 Standard delivery, extension kit
rR Heating circuit pump, heating circuit M3 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Circulation pump on-site
rZ Separate mixer motor As per Viessmann pricelist
System separation rU
rU Plate heat exchanger Vitotrans 100 As per Viessmann pricelist
Low loss header tP
tP Low loss header (in conjunction with Divicon heating circuit distributor) As per Viessmann pricelist
tQ Flow temperature sensor for low loss header 7179 488
Accessories
5 Internal extension H2 7179 144
6 Extension AM1 7429 152
7 Extension EA1 7429 151
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension EA1 7
Extension AM1 6
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
5822 470 GB

System examples VIESMANN 71


Boiler wall mounted, 3.8 to 35 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M SLP
1~
40 7 L

5
2
LON 69
2 L
96
5 96 N
L
P
X3.9
157 M 61
X3.8
S N
3 X3.7
X3.6
N
28 M SLP
X3.5 VTS 1~
51 L
X3.4
Low voltage

X3.3
67 68

X3.2 3
ATS 3 2 145
X3.1
1 3
145 2
KM BUS 65 66 70
1
8
9 3
145 2
6 KOL 21 1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145
1 1

6
7
N
40A 40
L
N
40A 40 41
L
N
A1
L
N
A2 M
1~ ZP 12
L

2 2 145 41
145
1 1

ID: 4605138_1001_01
5822 470 GB

72 VIESMANN System examples


Boiler wall mounted, 3.8 to 35 kW (cont.)

Note
The cylinder primary pump (SLP) on the Vitodens 343-F is integrated
and fully wired.

41
6
N
40A 40
L N
40A 40 31
L

M 45
1~

42
N
M
20 1~ 44
L

N
52 M
1~ 46

3
2
2 1 VTS M3 43

6
145 2 2
145
1 1

31
41
N
40A 40
L N
40A
L

N
20 M
1~ M2 34
L

N
52 M
1~ 36

2
2 1 VTS M2 33

2 2
145
1 1

ID: 4605138_1001_01
5822 470 GB

System examples VIESMANN 73


Boiler wall mounted, 45 to 105 kW

4.1 Overview of sample applications


One heating circuit without mixer with low loss header Three or more heating circuits with mixer and low loss header
See page 75 See page 98

ID: 4605139_1001_01 ID: 4605143_1001_01


One heating circuit with mixer and low loss header Three or more heating circuits with mixer and low loss header
See page 79 See page 103

ID: 4605140_1001_01 ID: 4605144_1001_01


One heating circuit with mixer, without low loss header, with system
4 separation
See page 84

ID: 4605141_1001_01
One heating circuit without mixer, two heating circuits with mixer and
low loss header
See page 89

ID: 4605142_1001_01
Multi-boiler system
See page 94
5822 470 GB

ID: 4605016_1001_03

74 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

4.2 One heating circuit without mixer with low loss header
Main components
Gas condensing boiler 1 Vitodens 200-W, 45 to 105 kW
Vitotronic 100 (for constant temperature mode) or Vitotronic 200 (for
weather-compensated mode)
Heating circuit connection set iP with circulation pump
Low loss header tP
DHW heating:
DHW cylinder qP
Connection set for DHW cylinders iQ

ID: 4605139_1001_01 Function description


Circulation pump tW supplies heating circuit eP or the boiler circuit up
to the low loss header. DHW cylinder qP is supplied by circulation
Applications pump qZ.
Heating system with an unregulated radiator circuit eP: For systems with a low loss header, on-site heating circuit pump A1
with low loss header tP eQ supplies heating circuit eP.
(see "Specification")
DHW heating by the Vitodens. Heating mode
Control unit 2 of boiler 1 regulates the boiler water temperature (=
Specification flow temperature of heating circuit eP) in weather-compensated or
If the total flow rate of all heating circuits is greater than the max. pos- room temperature-dependent mode.
sible flow rate of boiler (see table), use a low loss header tP. Heating circuit pump A1 eQ of radiator heating circuit eP is regulated
by internal extension H1 4/H2 5 or extension AM1 6.
Boiler Max. flow rate
l/h DHW heating by boiler
Vitodens 200-W, 17 - 45 kW 3500 Circulation pump for cylinder heating qZ starts when the set DHW
Vitodens 200-W, 17 - 60 kW 3500 temperature selected at control unit 2 is no longer being achieved. 4
Vitodens 200-W, 30 - 80 kW 5700 Within the periods selected at control unit 2, DHW is heated with and
Vitodens 200-W, 30 - 105 kW 5700 without priority.
DHW circulation pump ZP qW is connected, subject to system equip-
We recommend installing a low loss header tP if the minimum flow ment, either to internal extension H1 4 or H2 5.
rates listed in the table below cannot be guaranteed.

Boiler Min. flow rate


l/h
Vitodens 200-W, 17 - 45 kW 450
Vitodens 200-W, 17 - 60 kW 450
Vitodens 200-W, 30 - 80 kW 1300
Vitodens 200-W, 30 - 105 kW 1300
5822 470 GB

System examples VIESMANN 75


Boiler wall mounted, 45 to 105 kW (cont.)

Hydraulic installation scheme ID: 4605139_1001_01

30

31
--x/x--

WW

51
-2/X3-

12
--x/x-- 3
--2/X3--

50

1
11
--2/5--

16 52
-2/20-
-6/A2-

KW 10

4 81 80
-KM-Bus-
-KM-Bus-
-KM-Bus-
--X3--
--X3--
--5--

2 4 5 6 7
--A1--
--96--

--40--
--40--
--20--

--A2--
--28--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
For the electrical connection x/x:
DHW circulation pump ZP qW is connected, subject to system equip-
ment, to internal extension H1 4 or H2 5, and heating circuit pump
A1 eQ to internal extension H1 4/H2 5 or to extension AM1 6.

Equipment required

ID: 4605139_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Constant temperature control unit
or
Control unit for weather-compensated operation
3 Outside temperature sensor ATS (only for weather-compensated mode)
System without DHW circulation:
6 Extension AM1 7429 152
System with DHW circulation additionally:
4 Internal extension H1 7179 057
or
5 Internal extension H2 7179 144
7 Extension EA1 7429 151
5822 470 GB

76 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

ID: 4605139_1001_01
Pos. Description Part no.
Room temperature controller/remote control
Constant temperature mode
8 Vitotrol 100, type UTA 7170 149
or
9 Vitotrol 100, type UTDB Z007 691
or
Vitotrol 100, type UTDB-RF Z007 692
DHW heating via boiler 1
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, connection set
iQ
qW DHW circulation pump ZP As per Vitoset pricelist
qZ Circulation pump for cylinder heating UPSB
45 and 60 kW Standard delivery, connection set
iQ
80 and 105 kW on-site
eP Heating circuit without mixer
eQ Heating circuit pump on-site
tP Low loss header
45 and 60 kW As per Vitoset pricelist
80 and 105 kW Z007 743
tQ Flow temperature sensor for low loss header
45 and 60 kW 7179 488
80 and 105 kW Standard delivery, low loss header
tP
tW Circulation pump Standard delivery, heating circuit
connection set iP
Accessories
4
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension AM1 6
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
iP Heating circuit connection set As per Viessmann pricelist
iQ Connection set for DHW cylinders As per Viessmann pricelist
5822 470 GB

System examples VIESMANN 77


Boiler wall mounted, 45 to 105 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ ZP 12 A1 31
40 7 L

L 5
M
20 1~ 52
N 2 L
96
2 96 N
LON 69
L
P
5 STS 11 157 M 61
S N
X3.7
X3.6 N
28 M A1 31
1~ ZP 12
X3.5 VTS L
51
X3.4
Low voltage

X3.3 68
67
3
X3.2 2 145
ATS 3
X3.1 1 3
145 2
KM BUS 65 66 70
4 1
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145
1 1

6
7
N
40A 40
L
N
40A
L
N
A1 M A1
1~ 31
L
N
A2 M
1~ UPSB 16
L

2 2
145
1 1

ID: 4605139_1001_01
5822 470 GB

78 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

4.3 One heating circuit with mixer and low loss header
Main components
Gas condensing boiler 1 Vitodens 200-W, 45 to 105 kW
Vitotronic 200 (for weather-compensated mode)
Heating circuit connection set iP with circulation pump
Low loss header tP
DHW heating:
DHW cylinder qP
Connection set for DHW cylinders iQ

Function description
ID: 4605140_1001_01 For systems with low loss header, circulation pump tW supplies the
boiler circuit up to the low loss header. DHW cylinder qP is supplied
by circulation pump qZ.
Applications Heating circuit pump M2 rR supplies underfloor heating circuit rP.
Heating system with regulated underfloor heating circuit rP:
with low loss header tP Heating mode
(see "Specification") The extension kit for one heating circuit with mixer rQ regulates the
DHW heating by the Vitodens. flow temperature of underfloor heating circuit rP in weather-compen-
sated mode.
Specification The boiler water temperature is raised by the differential temperature
If the total flow rate of all heating circuits is greater than the max. pos- set at control unit 2 of boiler 1.
sible flow rate of boiler (see table), use a low loss header tP. Heating circuit pump M2 rR of underfloor heating circuit rP is regula-
ted by extension kit for one heating circuit with mixer rQ.
Boiler Max. flow rate The flow rate of underfloor heating circuit rP (without system separa-
l/h tion), which is subject to individual design criteria, is balanced by an
Vitodens 200-W, 17 - 45 kW 3500 adjustable bypass.
Vitodens 200-W, 17 - 60 kW 3500 The maximum temperature of underfloor heating circuit rP is restricted 4
Vitodens 200-W, 30 - 80 kW 5700 by temperature limiter rW.
Vitodens 200-W, 30 - 105 kW 5700
DHW heating by boiler
We recommend installing a low loss header tP if the minimum flow Circulation pump for cylinder heating qZ starts when the set DHW
rates listed in the table below cannot be guaranteed. temperature selected at control unit 2 is no longer being achieved.
Within the periods selected at control unit 2, DHW is heated with and
Boiler Min. flow rate without priority.
l/h DHW circulation pump ZP qW is connected to extension AM1 6.
Vitodens 200-W, 17 - 45 kW 450
Vitodens 200-W, 17 - 60 kW 450
Vitodens 200-W, 30 - 80 kW 1300
Vitodens 200-W, 30 - 105 kW 1300
5822 470 GB

System examples VIESMANN 79


Boiler wall mounted, 45 to 105 kW (cont.)

Hydraulic installation scheme ID: 4605140_1001_01

40
42
--41/20--
43
--41/2--

44
--41/20--

--41/52--
WW
45

51
-2/X3-
12
--6/A1-- 3
--2/X3--

50

--KM-Bus--
--2--
1
11
--2/5-- 41

--52--
--20--
--230V--
16 52
--2/20--
--x/x--

4 KW 10

81
80
-KM-Bus-
-KM-Bus-
-KM-Bus-
--X3--
--X3--
--5--

2 4 5 6 7
--40A--
--96--

--40--
--40--
--20--

--A1--
--28--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
Circulation pump UPSB qZ for cylinder heating is connected, subject
to system equipment, either to internal extension H1 4/ H2 5 or to
extension AM1 6.

Equipment required

ID: 4605140_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation
3 Outside temperature sensor ATS
System without DHW circulation:
4 Internal extension H1 7179 057
or
5 Internal extension H2 7179 144
System with DHW circulation additionally:
6 Extension AM1 7429 152
7 Extension EA1 7429 151
DHW heating via boiler 1
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, connection set
iQ
5822 470 GB

qW DHW circulation pump ZP As per Vitoset pricelist


qZ Circulation pump for cylinder heating UPSB
45 and 60 kW Standard delivery, connection set
iQ

80 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

ID: 4605140_1001_01
Pos. Description Part no.
80 and 105 kW on-site
rP Heating circuit with mixer
rQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
rR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Separate mixer motor As per Viessmann pricelist
tP Low loss header
45 and 60 kW As per Vitoset pricelist
80 and 105 kW Z007 743
tQ Flow temperature sensor for low loss header
45 and 60 kW 7179 488
80 and 105 kW Standard delivery, low loss header
tP
tW Circulation pump Standard delivery, heating circuit
connection set iP
Accessories
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
4
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension AM1 6
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
iP Heating circuit connection set As per Viessmann pricelist
iQ Connection set for DHW cylinders As per Viessmann pricelist
5822 470 GB

System examples VIESMANN 81


Boiler wall mounted, 45 to 105 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ UPSB 16
40 7 L

L 5
M
20 1~ 52
N 2 L
96
2 96 N
LON 69
L
P
5 STS 11 157 M 61
S N
X3.7
X3.6 N
28 M
1~ UPSB 16
X3.5 VTS L
51
X3.4
Low voltage

X3.3 68
67
3
X3.2 2 145
ATS 3
X3.1 1 3
145 2
KM BUS 65 66 70
1
4
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2 145 6
145
1 1

ID: 4605140_1001_01
5822 470 GB

82 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

6
7
N
40A 40
L
N
40A 40 41
L
N
A1 M
1~ ZP 12
L
N
A2 M UPSB
1~ 16
L
7
145 2 2
145
1 1

41
6
N
40A 40
L N
40A
L
42
N
M
20 1~ M2 44
L

N
52 M
1~ 45
4
2
2 1 VTS M2 43

2 2
145
1 1

ID: 4605140_1001_01
5822 470 GB

System examples VIESMANN 83


Boiler wall mounted, 45 to 105 kW (cont.)

4.4 One heating circuit with mixer, without low loss header, with system separation
Main components
Gas condensing boiler 1 Vitodens 200-W, 45 to 105 kW
Vitotronic 200 (for weather-compensated mode)
Heating circuit connection set iP with circulation pump
DHW heating:
DHW cylinder qP
Connection set for DHW cylinders iQ

Function description
Circulation pump rZ supplies the primary circuit of plate heat
ID: 4605141_1001_01 exchanger (system separation) rU.
DHW cylinder qP is supplied by circulation pump qZ.
Heating circuit pump M2 rR supplies underfloor heating circuit rP.
Applications
Heating system with regulated underfloor heating circuit rP and sys- Heating mode
tem separation rU. The extension kit for one heating circuit with mixer rQ regulates the
DHW heating by the Vitodens. flow temperature of underfloor heating circuit rP in weather-compen-
sated mode.
Specification The boiler water temperature is raised by the differential temperature
If the total flow rate of all heating circuits is greater than the max. pos- set at control unit 2 of boiler 1.
sible flow rate of the boiler (see table), use a low loss header. Heating circuit pump M2 rR and circulation pump rZ of underfloor
heating circuit rP are regulated by extension kit for one heating circuit
Boiler Max. flow rate with mixer rQ.
l/h The maximum temperature of underfloor heating circuit rP is restricted
Vitodens 200-W, 17 - 45 kW 3500 by temperature limiter rW.
Vitodens 200-W, 17 - 60 kW 3500
4 Vitodens 200-W, 30 - 80 kW 5700 DHW heating by boiler
Vitodens 200-W, 30 - 105 kW 5700 Circulation pump for cylinder heating qZ starts when the set DHW
temperature selected at control unit 2 is no longer being achieved.
We recommend installing a low loss header if the minimum flow rates Within the periods selected at control unit 2, DHW is heated with and
listed in the table below cannot be guaranteed. without priority.
DHW circulation pump ZP qW is connected to extension AM1 6.
Boiler Min. flow rate
l/h
Vitodens 200-W, 17 - 45 kW 450
Vitodens 200-W, 17 - 60 kW 450
Vitodens 200-W, 30 - 80 kW 1300
Vitodens 200-W, 30 - 105 kW 1300

5822 470 GB

84 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

Hydraulic installation scheme ID: 4605141_1001_01

40
42
--41/20--
43
--41/2--

44
--41/20--
47

WW --41/20-- 46

--41/52--
45

12
--6/A1-- 3
--2/X3--

--KM-Bus--
--2--
1
11
--2/5-- 41

--52--
--20--
--230V--
16 52
--2/20--
--x/x--

KW 10 4
81
80
-KM-Bus-
-KM-Bus-
-KM-Bus-
--X3--
--X3--
--5--

2 4 5 6 7
--96--

--40--
--40--
--20--
--28--

--40A--
--230V--

--A2--
--A1--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
Circulation pump UPSB qZ for cylinder heating is connected, subject
to system equipment, either to internal extension H1 4/ H2 5 or to
extension AM1 6.

Equipment required

ID: 4605141_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation
3 Outside temperature sensor ATS
System without DHW circulation:
4 Internal extension H1 7179 057
or
5 Internal extension H2 7179 144
System with DHW circulation additionally:
6 Extension AM1 7429 152
7 Extension EA1 7429 151
DHW heating via boiler 1
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, connection set
iQ
5822 470 GB

qW DHW circulation pump ZP As per Vitoset pricelist


qZ Circulation pump for cylinder heating UPSB
45 and 60 kW Standard delivery, connection set
iQ

System examples VIESMANN 85


Boiler wall mounted, 45 to 105 kW (cont.)

ID: 4605141_1001_01
Pos. Description Part no.
80 and 105 kW on-site
rP Heating circuit with mixer
rQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
rR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Separate mixer motor As per Viessmann pricelist
rZ Circulation pump on-site
rI Junction box on-site
System separation rU
rU Plate heat exchanger Vitotrans 100 As per Viessmann pricelist
tW Circulation pump Standard delivery, heating circuit
connection set iP
Accessories
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
4 External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension AM1 6
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
iP Heating circuit connection set As per Viessmann pricelist
iQ Connection set for DHW cylinders As per Viessmann pricelist
5822 470 GB

86 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ UPSB 16
40 7 L

L 5
M
20 1~ 52
N 2 L
96
2 96 N
LON 69
L
P
5 157 M 61
STS 11
S N
X3.7
X3.6 N
28 M
1~ UPSB 16
X3.5 L
X3.4
Low voltage

X3.3 68
67
3
X3.2 2 145
ATS 3
X3.1 1 3
145 2
KM BUS 65 66 70
1
4
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2 145 6
145
1 1

ID: 4605141_1001_01
5822 470 GB

System examples VIESMANN 87


Boiler wall mounted, 45 to 105 kW (cont.)

6
7
N
40A 40
L
N
40A 40 41
L
N
A1 M
1~ ZP 12
L
N
A2 M UPSB
1~ 16
L
7
145 2 2
145
1 1

41
6
N
40A 40
L
40A M 46
1~

48 42
N
M
20 1~ M2 44
L

N
52 M
1~ 45
4
2
2 1 VTS M2 43

2 2
145
1 1

ID: 4605141_1001_01

5822 470 GB

88 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

4.5 One heating circuit without mixer with separate heating circuit pump and two heating
circuits with mixer, with low loss header
Function description
Circulation pump tW supplies the boiler circuit up to the low loss
header. DHW cylinder qP is supplied by circulation pump qZ.
Heating circuit pump A1 eQ supplies radiator circuit eP.
Heating circuit pump M2 rR supplies underfloor heating circuit rP.
Circulation pump rZ supplies the primary circuit of plate heat
exchanger (system separation) rU.
Heating circuit pump M3 oR supplies radiator circuit oP.

Heating mode
ID: 4605142_1001_01
Heating circuit without mixer
Control unit 2 of boiler 1 regulates the boiler water temperature (=
Applications flow temperature of heating circuit without mixer eP) in weather-com-
Heating system with unregulated heating circuit eP and: pensated mode.
Regulated radiator heating circuit oP Heating circuit pump A1 eQ of radiator heating circuit eP is regulated
and by internal extension H1 4/H2 5 or extension AM1 6.
Regulated underfloor heating circuit rP with system separation rU
DHW heating by the Vitodens. Heating circuit with mixer
Extension kit for one heating circuit with mixer rQ or oQ regulates the
Specification flow temperature of underfloor heating circuit rP or radiator heating
The total flow rate of both heating circuits is greater than the max. circuit oP in weather-compensated mode.
possible flow rate of the boiler (see table), therefore use a low loss The boiler water temperature is raised by the differential temperature
header tP. set at control unit 2 of boiler 1.
Heating circuit pump M2 rR and circulation pump rZ (only with system
Boiler Max. flow rate separation) of underfloor heating circuit rP are regulated by extension 4
l/h kit for one heating circuit with mixer rQ.
Vitodens 200-W, 17 - 45 kW 3500 Heating circuit pump M3 oR of the radiator heating circuit is regulated
Vitodens 200-W, 17 - 60 kW 3500 by extension kit for one heating circuit with mixer oQ.
Vitodens 200-W, 30 - 80 kW 5700 The maximum temperature of underfloor heating circuit rP is restricted
Vitodens 200-W, 30 - 105 kW 5700 by temperature limiter rW.

Main components DHW heating by boiler


Gas condensing boiler 1 Vitodens 200-W, 45 to 105 kW Circulation pump for cylinder heating UPSB qZ starts when the set
Vitotronic 200 (for weather-compensated mode) DHW temperature selected at control unit 2 is no longer achieved.
Heating circuit connection set with circulation pump iP Within the periods selected at control unit 2, DHW is heated with and
Low loss header tP without priority.
DHW heating: DHW circulation pump ZP qW is connected, subject to system equip-
DHW cylinder qP ment, either to internal extension H1 4 or H2 5.
Connection set for DHW cylinders iQ
5822 470 GB

System examples VIESMANN 89


Boiler wall mounted, 45 to 105 kW (cont.)

Hydraulic installation scheme ID: 4605142_1001_01

30 90 40
42
-41/20-
93 43
-91/2- --41/2--

44
94 --41/20--
31 -91/20-
--x/x-- 47

-91/52-
WW 95 --41/20-- 46

51 -41/52-
-2/X3- 45

12 3
--x/x--
--2/X3--

50

--KM-Bus--

--KM-Bus--
11
--2/5--

--2--

--2--
91 41
16 52

--52--
--20--

--52--
--20--
--230V--

--230V--
--2/20--
-6/A2-

4 KW 10

81
80
-KM-Bus-
-KM-Bus-
-KM-Bus-

--A1--
--X3--
--X3--

--A2--
--5--

2 4 5 6 7
--96--

--40--
--40--
--20--
--28--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
For the electrical connection x/x:
DHW circulation pump ZP qW is connected, subject to system equip-
ment, to internal extension H1 4/ H2 5, and heating circuit pump
A1 eQ to internal extension H1 4/H2 5 or to extension AM1 6.

Equipment required

ID: 4605142_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation
3 Outside temperature sensor ATS
System without DHW circulation:
6 Extension AM1 7429 152
System with DHW circulation additionally:
4 Internal extension H1 7179 057
or
5 Internal extension H2 7179 144
7 Extension EA1 7429 151
DHW heating via boiler 1
qP Mono-mode DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, connection set
5822 470 GB

iQ
qW DHW circulation pump ZP As per Vitoset pricelist

90 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

ID: 4605142_1001_01
Pos. Description Part no.
qZ Circulation pump for cylinder heating UPSB
45 and 60 kW Standard delivery, connection set
iQ
80 and 105 kW on-site
eP Heating circuit I
eQ Heating circuit pump, heating circuit A1 on-site
or
Divicon As per Viessmann pricelist
rP Heating circuit with mixer II
rQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit with mixer M2 Standard delivery, extension kit
rR Heating circuit pump, heating circuit with mixer M2 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Separate mixer motor As per Viessmann pricelist
rZ Circulation pump on-site
rI Junction box on-site
System separation rU
rU Plate heat exchanger Vitotrans 100 As per Viessmann pricelist
oP Heating circuit with mixer III
4
oQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
oE Flow temperature sensor, heating circuit M3 Standard delivery, extension kit
oR Heating circuit pump, heating circuit M3 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
oT Separate mixer motor As per Viessmann pricelist
tP Low loss header
45 and 60 kW see Vitoset pricelist
80 and 105 kW Z007 743
tQ Flow temperature sensor for low loss header
45 and 60 kW 7179 488
80 and 105 kW Standard delivery, low loss header
tP
tW Circulation pump Standard delivery, heating circuit
connection set iP
Accessories
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension AM1 6
Extension EA1 7
Vitotrol 200A zT
5822 470 GB

Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or

System examples VIESMANN 91


Boiler wall mounted, 45 to 105 kW (cont.)

ID: 4605142_1001_01
Pos. Description Part no.
zO Vitocom 200, type GP1 As per Viessmann pricelist
iP Heating circuit connection set As per Viessmann pricelist
iQ Connection set for DHW cylinders As per Viessmann pricelist

Electrical installation scheme

4
2
2 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ ZP 12 A1 31
40 7 L

L 5
M
20 1~ 52
N 2 L
96
2 96 N
LON 69
L
P
5 STS 11 157 M 61
S N
X3.7
X3.6 N
28 M A1 31
1~ ZP 12
X3.5
4 X3.4
VTS 51 L
Low voltage

X3.3 68
67
3
X3.2 2 145
ATS 3
X3.1 1 3
145 2
KM BUS 65 66 70
1
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2 145 6
145
1 1

ID: 4605142_1001_01
5822 470 GB

92 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

6
7
N
40A 40
L
N
40A 40 41
L
N
A1 M
1~ A1 31
L
N
A2 M UPSB
1~ 16
L
7
145 2 2
145
1 1

41
6
N
40A 40
L N
40A 40 91
L

M 46
1~

48 42
N
M
20 1~ M2 44
L

N
4
52 M
1~ 45

2
2 1 VTS M2 43

2 2
145
1 1

91
41
N
40A 40
L N
40A
L

N
M
20 1~ M3 94
L
N
52 M
1~ 95

2
2 1 VTS M3 93

2 2
145
1 1

ID: 4605142_1001_01
5822 470 GB

System examples VIESMANN 93


Boiler wall mounted, 45 to 105 kW (cont.)

4.6 Multi-boiler system with several heating circuits with mixer and low loss header
Heating circuit pumps M2, M3 rR supply heating circuits rP.

Heating mode

Heating circuits with mixer


Circulation pumps tW/tE integrated into the connection accessories
start subject to demand.
The underfloor heating circuit and radiator circuits are each supplied
by a separate circulation pump. Each heating circuit is regulated by
Vitotronic 300-K 6 via an extension kit for heating circuits with mixer.
ID: 4605016_1001_03
A Vitotronic 200-H, type HK1M, is additionally required if three heating
circuits with mixer are connected. A Vitotronic 200-H, type HK3W, is
Applications additionally required if four or more heating circuits with mixer are con-
Heating system with different heating circuits: nected.
Regulated radiator circuit rP with 3-way mixer The flow rate of underfloor heating circuit rP, which is subject to indi-
and vidual design criteria, is balanced by an adjustable bypass.
Regulated underfloor heating circuit rP with 3-way mixer The maximum temperature of underfloor heating circuit rP is restricted
DHW heating by the Vitodens by temperature limiter rW.

DHW heating
Main components Circulation pump for cylinder heating UPSB qZ starts when the set
Multi-boiler system 1 Vitodens 200-W, 45 to 105 kW with DHW temperature selected at control unit 6 is no longer achieved.
Hydraulic cascade with low loss header Within the periods selected at the control unit, DHW is heated with and
Vitotronic 100 for every boiler without priority. The priority control can be adjusted separately for each
Vitotronic 300-K heating circuit.
Connection accessories DHW circulation pump ZP qW is connected to control unit 6.
4 DHW cylinder qP

Function description
Circulation pumps tW/tE integrated into the connection accessories
supply the boiler circuit up to the low loss header. DHW cylinder qP is
supplied by circulation pump qZ.

5822 470 GB

94 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

Hydraulic installation scheme ID: 4605016_1001_03

40 40 7
42
--6/20--

--6/1--
43 43
--6/2-- --6/2--

44 44
--6/20-- --6/20--
45 45
--6/52-- --6/52--
WW

12
--- 3 7
--6/28--

--6/1--
--6/2--

11 51
--6/5--

52 53
--2/20-- --5/20-- 50
--6/21--

16
KW 10
1 4
--KM-Bus--

--KM-Bus--

--KM-Bus--
--143--

--2--
--1--
--5--

2 4 5 4 6
--20--

--20--
--230V--

--230V--

--50--
--28--

--20--
--52--
--21--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605016_1001_03
Pos. Description Part no.
1 Multi-boiler system with 2, 3 or 4 Vitodens 200-W, hydraulic cascade with low loss header As per Viessmann pricelist
and connection accessories
with
2 Constant temperature control unit
5 Constant temperature control unit
3 Cascade communication module Multi-boiler system standard deliv-
ery
6 Vitotronic 300-K Multi-boiler system standard deliv-
ery
7 Outside temperature sensor ATS Multi-boiler system standard deliv-
ery
DHW heating
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS Multi-boiler system standard deliv-
ery
qW DHW circulation pump ZP As per Vitoset pricelist
qZ Circulation pump for cylinder heating UPSB on-site
5822 470 GB

System examples VIESMANN 95


Boiler wall mounted, 45 to 105 kW (cont.)

ID: 4605016_1001_03
Pos. Description Part no.
rP Heating circuit with mixer
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor, heating circuit M2/M3 Standard delivery, extension kit
rR Heating circuit pump, heating circuit M2/M3 on-site
and
3-way mixer As per Viessmann pricelist
rT Extension kit for heating circuit with mixer (mixer motor and flow temperature sensor rE) 7450 650
tP Low loss header Standard delivery, hydraulic cas-
cade
tQ Flow temperature sensor for low loss header Standard delivery, hydraulic cas-
cade
tW Circulation pump Standard delivery, hydraulic cas-
cade
tE Circulation pump Standard delivery, hydraulic cas-
cade
Accessories
4 Internal extension H1 7179 057
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zW Central fault message on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR Function extension 0 to 10 V 7174 718
4 zT Vitotrol 200 (KM BUS subscriber) 7450 017
zZ Vitotrol 300 (KM BUS subscriber) 7248 907
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Vitotronic 300-K 6
Vitotrol 200 zT
Vitotrol 300 zZ
zO Vitocom 200 or 300 As per Viessmann pricelist

5822 470 GB

96 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

Electrical installation scheme

2 N N
40 230 V / 50 Hz 40 230 V / 50 Hz
L L
230 V / 50 Hz

N N
20 M
52 50 S 62
1~ L
L
42
N
20 M
1~ M3 44
M3
L
3
4 N
Low voltage

KMK2 3 20 M M2 44
1~
M2 L
2
KMK1 1
N
52 M
1~ M2/M3 45
M2/M3

N
21 M
1~ UPSB 16
L

N
28 M
1~ ZP 12
L

2 2
5 M2/M3 43
N M2/M3 1
40 230 V / 50 Hz 4
L 2
143 63
230 V / 50 Hz

1
N
20 M 2
1~ 53
2 1 VTS 51
L
2
5 1 STS 11

3
67
3 1
2
4 ATS 7
Low voltage

KMK2 3 1
2 1 2
KMK1 1 145 KM BUS 64 65 66 70
2 1

2
LON 69

ID: 4605016_1001_03
5822 470 GB

System examples VIESMANN 97


Boiler wall mounted, 45 to 105 kW (cont.)

4.7 Three or more heating circuits with mixer and low loss header
Low loss header tP
DHW heating:
DHW cylinder qP
Connection set for DHW cylinders iQ

Function description
Circulation pump tW supplies the boiler circuit up to the low loss
header. DHW cylinder qP is supplied by circulation pump qZ.
Heating circuit pumps M1, M2, M3 rR/oR supply heating circuit rP or
heating circuits oP.
ID: 4605143_1001_01
Heating mode

Applications Heating circuits with mixer


Heating system with different heating circuits: The underfloor heating circuit and radiator circuits are each supplied
Regulated heating circuits oP by a separate circulation pump M1, M2, M3 rR/oR. These heating cir-
and cuits are respectively regulated via extension kits for one heating cir-
Regulated underfloor heating circuit rP cuit with mixer oQ and one Vitotronic 200-H, type HK1M rQ.
DHW heating by the Vitodens. The boiler water temperature is regulated according to the highest
demand (increased flow temperature by an adjustable differential tem-
Specification perature).
The total flow rate of all heating circuits is greater than the maximum The flow rate of underfloor heating circuit rP (without system separa-
possible flow rate of boiler (see table), therefore use a low loss header tion), which is subject to individual design criteria, is balanced by an
tP. adjustable bypass.
The maximum temperature of underfloor heating circuit rP is restricted
Boiler Max. flow rate by temperature limiter rW.
l/h
4 DHW heating by boiler
Vitodens 200-W, 17 - 45 kW 3500
Vitodens 200-W, 17 - 60 kW 3500 Circulation pump for cylinder heating UPSB qZ starts when the set
Vitodens 200-W, 30 - 80 kW 5700 DHW temperature selected at control unit 2 is no longer achieved.
Vitodens 200-W, 30 - 105 kW 5700 Within the periods selected at control unit 2, DHW is heated with and
without priority.
Main components DHW circulation pump ZP qW is connected, subject to system equip-
Gas condensing boiler 1 Vitodens 200-W, 45 to 105 kW ment, either to internal extension H1 4/ H2 5 or to extension AM1
Vitotronic 200 (for weather-compensated mode) 6.
Heating circuit connection set iP with circulation pump

5822 470 GB

98 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

Hydraulic installation scheme ID: 4605143_1001_01

90 90 40
42
-41/20-
93 93 43
-91/2- -91/2- -41/2-

94 94 44
-91/20- -91/20- -41/20-
95 95 45
-91/52- -91/52- -41/52-
WW

51
-2/X3-

12
-- 3
--x/x--

--2/X3--

50

--KM-Bus--
--KM-Bus--

--KM-Bus--
1
11
--2/5--

--2--
--2--
--2--

91 91 41
16

--52--
--20--
--52--
--20--
--52--
--20--

--230V--
--230V--
--230V--

52
--2/20--
--x/x--

KW 10 4
81
80
-KM-Bus-
-KM-Bus-
-KM-Bus-

--A1--
--X3--
--X3--

--A2--
--5--

2 4 5 6 7
--96--

--40--
--40--
--20--
--28--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Note
For the electrical connection x/x:
DHW circulation pump ZP qW and circuit pump for cylinder heating
UPSB qZ are connected, subject to system equipment, either to inter-
nal extension H1 4/ H2 5 or to extension AM1 6.

Equipment required

ID: 4605143_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation
3 Outside temperature sensor ATS
8 LON communication module 7179 113
System without DHW circulation:
4 Internal extension H1 7179 057
or
5 Internal extension H2 7179 144
System with DHW circulation additionally:
6 Extension AM1 7429 152
7 Extension EA1 7429 151
DHW heating via boiler 1
qP DHW cylinder As per Viessmann pricelist
5822 470 GB

qQ Cylinder temperature sensor STS Standard delivery, connection set


iQ
qW DHW circulation pump ZP As per Vitoset pricelist
qZ Circulation pump for cylinder heating UPSB

System examples VIESMANN 99


Boiler wall mounted, 45 to 105 kW (cont.)

ID: 4605143_1001_01
Pos. Description Part no.
45 and 60 kW Standard delivery, connection set
iQ
80 and 105 kW on-site
oP Heating circuits with mixer I and II
oQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062

(Note: a separate extension kit is required for every individual heating circuit)
oE Flow temperature sensor, heating circuit M2/M3 Standard delivery, extension kit
oR Heating circuit pump, heating circuit M2/M3 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
oT Mixer motor part of the standard delivery oQ or
separate
rP Heating circuit with mixer III
rQ Vitotronic 200-H, type HK1M with Z004 980
rI LON communication module 7172 173
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor heating circuit M1 Standard delivery, extension kit
rR Heating circuit pump, heating circuit M1 on-site
and
4 3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Mixer motor As per Viessmann pricelist
tP Low loss header
45 and 60 kW As per Vitoset pricelist
80 and 105 kW Z007 743
tQ Flow temperature sensor for low loss header
45 and 60 kW 7179 488
80 and 105 kW Standard delivery, low loss header
tP
tW Circulation pump Standard delivery, heating circuit
connection set iP or on-site provi-
sion
Accessories
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A for Vitotronic 200, type HO1A (KM BUS subscriber) Z008 341
(Vitotrol 200 for Vitotronic 200-H, type HK1M)
zZ Vitotrol 300A for Vitotronic 200, type HO1A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension AM1 6
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
iP Heating circuit connection set As per Viessmann pricelist
5822 470 GB

iQ Connection set for DHW cylinders As per Viessmann pricelist

100 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V/ 50 Hz 96 N
L
230 V/ 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ UPSB 16 ZP 12
40 7 L

L 5
M
20 1~ 52
N 2 L
96
2 96 N
LON 69 41
L
P
5 STS 11 157 M 61
S N
X3.7
X3.6 N
28 M
1~ UPSB 16 ZP 12
X3.5 VTS L
51
X3.4
Low voltage

X3.3 68
67
3
X3.2 2 145
ATS 3
X3.1 1 3
145 2
KM BUS 65 66 70
1
4
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2 145 6
145
1 1

ID: 4605143_1001_01
5822 470 GB

System examples VIESMANN 101


Boiler wall mounted, 45 to 105 kW (cont.)

6
7
N
40A 40
L
N
40A 40 91
L
N
A1 M
1~ ZP 12
L
N
A2 M UPSB
1~ 16
L
7
145 2 2
145
1 1

91
6
N
40A 40
L N
40A
L

20 N
M M2/M3 94
1~
L
N
52 M M2/M3 95
1~

4
2
2 1 M2/M3 93

2
145
1

41

N
40 230 V / 50 Hz
L

42
N
20 M
1~ M1 44
L

N
52 M M1
1~ 45

48 2
2 2 1 M1 43
2 LON

2
145
1

ID: 4605143_1001_01
5822 470 GB

102 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

4.8 Three or more heating circuits with mixer, low loss header and solar DHW heating
The boiler water temperature is regulated according to the highest
demand (increased flow temperature by an adjustable differential tem-
perature).
The flow rate of underfloor heating circuit rP (without system separa-
tion), which is subject to individual design criteria, is balanced by an
adjustable bypass.
The maximum temperature of underfloor heating circuit rP is restricted
by temperature limiter rW.

DHW heating by boiler


ID: 4605144_1001_01 Circulation pump for cylinder heating UPSB qZ starts when the set
DHW temperature selected at control unit 2 is no longer achieved.
Within the periods selected at control unit 2, DHW is heated with and
Applications without priority.
Heating system with different heating circuits: DHW circulation pump ZP qW is connected to extension AM1 6.
Regulated heating circuits oP
and DHW heating by the solar thermal system
Regulated underfloor heating circuit rP Solar circuit pump wE starts and DHW cylinder qE is heated up, if the
DHW heating by the Vitodens and with solar thermal system wP. temperature differential between collector temperature sensor wQ and
cylinder temperature sensor qR exceeds the start temperature differ-
Specification ential.
The total flow rate of all heating circuits is greater than the maximum
possible flow rate of boiler (see table), therefore use a low loss header Solar circuit pump wE stops if:
tP. The actual temperature drops below the stop temperature differen-
tial
Boiler Max. flow rate The electronic temperature limit (max. 90C) of the solar control unit
l/h (type SM1) wZ is exceeded
The temperature selected at high limit safety cut-out (STB) qT (if
4
Vitodens 200-W, 17 - 45 kW 3500
Vitodens 200-W, 17 - 60 kW 3500 installed) is reached
Vitodens 200-W, 30 - 80 kW 5700
Vitodens 200-W, 30 - 105 kW 5700 The requirements for the auxiliary function (see Vitosol technical
guide) are met by circulation pump wR.
Main components Circulation pump wR starts if at cylinder temperature sensor qI the
Gas condensing boiler 1 Vitodens 200-W, 45 to 105 kW start temperature differential (of the second temperature differential
Vitotronic 200 (for weather-compensated mode) controller) has exceeded the temperature at cylinder temperature sen-
Heating circuit connection set iP with circulation pump sor qU. The water heated in DHW cylinder 1 qE is supplied to DHW
Low loss header tP cylinder 2 qP.
DHW heating by the Vitodens without solar thermal system: Circulation pump wR starts if at cylinder temperature sensor qI the
DHW cylinder qP stop temperature differential (of the second temperature differential
Connection set for DHW cylinders iQ controller) no longer reaches the temperature at cylinder temperature
DHW heating by the Vitodens and a solar thermal system: sensor qU.
Dual mode DHW cylinder qE
Connection set for DHW cylinders iQ Suppression of reheating of the DHW cylinder by the boiler in
Solar thermal system wP conjunction with solar control module (type SM1)
Reheating suppression takes place in two stages.
Function description Reheating of DHW cylinder 2 qP by boiler 1 is suppressed, as soon
Circulation pump tW supplies the boiler circuit up to the low loss as DHW cylinder 1 qE is heated by collectors wP. For this, the set DHW
header. DHW cylinder qP is supplied by circulation pump qZ. temperature for reheating is reduced by boiler 1. Suppression
Heating circuit pumps M1, M2, M3 rR/oR supply heating circuit rP or remains active for a certain time after solar circuit pump wE has been
heating circuits oP. switched off.
In the case of uninterrupted heating by collectors wP (> 2 h) boiler
Heating mode 1 will only reheat, if the set cylinder temperature (coding address
"67") selected at boiler circuit control unit 2 is not achieved.
Heating circuits with mixer In control unit 2, coding address "67" defaults a third set DHW tem-
The underfloor heating circuit and radiator circuits are each supplied perature (setting range 10 to 95 C). This value must be below the first
by separate circulation pumps rR/oR. Heating circuit rP is regulated set DHW temperature.
via a Vitotronic 200-H, type HK1M rQ. Heating circuits oP are each DHW cylinder 2 will only be heated by boiler 1, if this set value cannot
regulated by extension kit for one heating circuit with mixer oQ. be achieved by the solar thermal system.
5822 470 GB

System examples VIESMANN 103


System examples VIESMANN 104
Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
5822 470 GB

--26/6--
21

23
22
Vorlauf

24
25

KW
--
----26/24--

--26/22--
Ruecklauf

15

1
20

-26/24-
13
18
12

14

--230V-- --KM-Bus--
--24-- --6--
--26/7--

--26/5--

--22-- --5--
WW

--6/A1--
26

--7--
--10--
2

10
17

11
--2/5--

--230V-- --5--
--26/10--

81

--28-- --X3--
--96-- --X3--
16

4 5

--20-- -KM-Bus- --x/x--


1

52
3

--40-- --2/X3--
--2/20--

6
--A2--
80
--A1-- -KM-Bus-
--40--

7
--40A--
-KM-Bus-
-2/X3-

4
51

50
93
--91/2--

94

95

--91/52--
--91/20--

--230V-- --2--
--52--
91
90

--20-- --KM-Bus--
95
--91/52--
--91/2--
93

94
--91/20--

--230V-- --2--
90

--52--

91
--20-- --KM-Bus--
--41/52--
45
--41/2--
42

43
--41/20--

44
--41/20--

--230V-- --2--
--52--

41
40

--20-- --KM-Bus--
Hydraulic installation scheme ID: 4605144_1001_01
Boiler wall mounted, 45 to 105 kW (cont.)
Boiler wall mounted, 45 to 105 kW (cont.)

Note
Circulation pump UPSB qZ for cylinder heating is connected, subject
to system equipment, either to internal extension H1 4/ H2 5 or to
extension AM1 6.

Equipment required

ID: 4605144_1001_01
Pos. Description Part no.
1 Boiler As per Viessmann pricelist
with
2 Control unit for weather-compensated operation
3 Outside temperature sensor ATS
8 LON communication module 7179 113
System without DHW circulation:
4 Internal extension H1 7179 057
or
5 Internal extension H2 7179 144
System with DHW circulation additionally:
6 Extension AM1 7429 152
7 Extension EA1 7429 151
DHW heating via boiler 1
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, connection set
iQ
qW DHW circulation pump ZP As per Vitoset pricelist
qZ Circulation pump for cylinder heating UPSB
45 and 60 kW Standard delivery, connection set
iQ
4
80 and 105 kW on-site
DHW heating via solar thermal system wP
qE DHW cylinder (solar preheating) As per Viessmann pricelist
qQ Cylinder temperature sensor STS Standard delivery, connection set
iQ
qR Cylinder temperature sensor part of the standard delivery of pos.
26
qT High limit safety cut-out STB Z001 889
qU Cylinder temperature sensor 7438 702
qI Cylinder temperature sensor 7438 702
wP Solar collectors As per Viessmann pricelist
wZ Solar control module, type SM1 7429 073
wQ Collector temperature sensor KOL part of the standard delivery of pos.
26
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump Standard delivery, Solar-Divicon
wR Circulation pump (transfer) on-site
wT Automatic thermostatic mixing valve 7438 940
wU Junction box on-site
5822 470 GB

System examples VIESMANN 105


Boiler wall mounted, 45 to 105 kW (cont.)

ID: 4605144_1001_01
Pos. Description Part no.
oP Heating circuits with mixer I and II
oQ Extension kit for one heating circuit with mixer with integral mixer motor 7301 063
or
Extension kit for one heating circuit with mixer for separate mixer motor 7301 062
oE Flow temperature sensor, heating circuits with mixer M2, M3 Standard delivery, extension kit
oR Heating circuit pump, heating circuit with mixer M2, M3 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
oT Mixer motor part of the standard delivery oQ or
separate
rP Heating circuits with mixer III
rQ Vitotronic 200-H, type HK1M with Z004 980
rI LON communication module 7172 173
rW Temperature limiter for limiting the maximum temperature of underfloor heating systems
as immersion thermostat 7151 728
or
as contact thermostat 7151 729
rE Flow temperature sensor heating circuit M1 Standard delivery, extension kit
rR Heating circuit pump, heating circuit M1 on-site
and
3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
rT Mixer motor As per Viessmann pricelist
tP Low loss header
4 45 and 60 kW As per Vitoset pricelist
80 and 105 kW Z007 743
tQ Flow temperature sensor for low loss header
45 and 60 kW 7179 488
80 and 105 kW Standard delivery, low loss header
tP
tW Circulation pump Standard delivery, heating circuit
connection set iP or on-site provi-
sion
Accessories
zP External safety solenoid valve for LPG (requires internal extension H1) on-site
zQ Interlocking of extractors (requires internal extension H2) on-site
zW Central fault message (requires extension EA1) on-site
zE External hook-up: on-site
External blocking
External demand
External heating program changeover (only weather-compensated mode)
zR External set value 0 - 10 V (requires extension EA1) on-site
zT Vitotrol 200A (KM BUS subscriber) Z008 341
(Vitotrol 200 for Vitotronic 200-H, type HK1M: 7450 017)
zZ Vitotrol 300A (KM BUS subscriber) Z008 342
zU Radio clock receiver 7450 563
zI KM BUS distributor, for several KM BUS subscribers 7415 028
KM BUS subscriber: As per Viessmann pricelist
Extension AM1 6
Extension EA1 7
Vitotrol 200A zT
Vitotrol 300A zZ
Vitocom 100 uP
Solar control module, type SM1 wZ
uP Vitocom 100, type GSM As per Viessmann pricelist
or
zO Vitocom 200, type GP1 As per Viessmann pricelist
iP Heating circuit connection set As per Viessmann pricelist
iQ Connection set for DHW cylinders As per Viessmann pricelist
5822 470 GB

106 VIESMANN System examples


Boiler wall mounted, 45 to 105 kW (cont.)

Electrical installation scheme

4
2
2 L
N
96
40 230 V/ 50 Hz 96 N
L
230 V/ 50 Hz

N
60
53 L
L
96 96 4 5 1
N
N
28 M
1~ UPSB 16
40 7 L

L 5
M
20 1~ 52
N 2 L
96
2 96 N
LON 69 41
L
P
5 STS 11 157 M 61
S N
X3.7
X3.6 N
28 M
1~ UPSB 16
X3.5 VTS L
51
X3.4
Low voltage

X3.3 68
67
3
X3.2 2 145
ATS 3
X3.1 1 3
145 2
KM BUS 66 70
1
4
3
145 2
1

2 N
40
96 L
N
40A 40 6
L
P
157
S 62
S

4
0-10V 64
3
2
DE1 63
1
2 2
145
1 1

6
7
N
40A 40
L
N
40A 40 91
L
N
A1 M
1~ ZP 12
L
N
A2 M UPSB 16
1~
L

2 2 145 91
145
1 1

ID: 4605144_1001_01
5822 470 GB

System examples VIESMANN 107


Boiler wall mounted, 45 to 105 kW (cont.)

91
6
N
40A 40
L N
40A 40 26
L

20 N
M M2/M3
1~ 94
L
N
52 M M2/M3
1~ 95

2
2 1 M2/M3 93

6
2 2
145 145
1 1

26
91
N
40A 40
L
N
24 M
1~ 23
L
27
STB 15

4 22
N
M
1~ 24
L
2
PWM
1
4
10 STS2 17
3
2
7 STS1 18
1
4
6 KOL 21
3
2
5 SOL 14
1
2
1 145

41

N
40 230 V/ 50 Hz
L

42
N
20 M
1~ M1 44
L

N
52 M M1
1~ 45

48
2 2 2
LON 2 1 M1 43

2
145 65
1

ID: 4605144_1001_01
5822 470 GB

108 VIESMANN System examples


Solid fuel boiler

5.1 Overview of sample applications


Vitoligno 100-S with one or several heating circuits with mixer, heating Vitoligno 100-S wall mounted oil or gas boiler, one or several heating
water buffer cylinder and DHW heating (optional with dual mode DHW circuits with mixer, heating water buffer cylinder and DHW heating with
cylinder and solar thermal system) multi-mode heating water buffer cylinder
See page 111 See page 134

ID: 4605017_1001_02 ID: 4605078_1001_02


Vitoligno 100-S with oil / gas boiler, one or several heating circuits with Vitolig 200 with one or two heating circuits with mixer, heating water
mixer, heating water buffer cylinder and DHW heating (optional with buffer cylinder and DHW cylinder
dual mode DHW cylinder and solar thermal system) See page 139
See page 115

ID: 4605018_1001_02 ID: 4605021_1001_03


Vitoligno 100-S with wall mounted oil or gas boiler, one or several heat- Vitolig 200 with oil/gas boiler, one or two heating circuits with mixer,
ing circuits with mixer, heating water buffer cylinder and DHW heating heating water buffer cylinder and DHW heating
(optional with dual mode DHW cylinder and solar thermal system) See page 143
See page 122

ID: 4605019_1001_02 ID: 4605150_1001_01


Vitoligno 100-S with oil or gas boiler, one or several heating circuits with Vitolig 200 with wall mounted oil/gas boiler, one or two heating circuits
mixer, heating water buffer cylinder and DHW heating with multi-mode with mixer, heating water buffer cylinder and DHW cylinder
heating water buffer cylinder See page 149
See page 130

ID: 4605020_1001_02 ID: 4605151_1001_01


5822 470 GB

System examples VIESMANN 109


Solid fuel boiler (cont.)

Vitolig 200 with oil/gas boiler, one or two heating circuits with mixer, Vitoligno 300-P with one or two heating circuits with mixer, heating
heating water buffer cylinder and multi-mode heating water buffer cyl- water buffer cylinder and DHW cylinder (optional with dual mode DHW
inder with DHW heating cylinder and solar thermal system)
See page 156 See page 170

ID: 4605152_1001_01 ID: 4605025_1001_02


Vitolig 200 with wall mounted oil/gas boiler, one or two heating circuits Vitoligno 300-P with one or two heating circuits with mixer, solar buffer
with mixer, heating water buffer cylinder and multi-mode heating water cylinder (for solar central heating backup) and DHW cylinder (optional
buffer cylinder with DHW heating with dual mode DHW cylinder and solar thermal system with Vitosolic
See page 161 200)
See page 174

ID: 4605153_1001_01 ID: 4605026_1001_02


Vitoligno 300-P with one or two heating circuits with mixer, DHW cylin- Vitolig 300-P with one or two heating circuits with mixer, multi-mode
der (optional with dual mode DHW cylinder and solar thermal system) heating water buffer cylinder and solar thermal system
See page 166 See page 179

ID: 4605024_1001_02 ID: 4605027_1001_02

5822 470 GB

110 VIESMANN System examples


Solid fuel boiler (cont.)

5.2 Vitoligno 100-S with one or several heating circuits with mixer, heating water buffer
cylinder and DHW heating (optional with dual mode DHW cylinder and solar thermal sys-
tem)
DHW heating by Vitoligno 100-S
Circulation pump for cylinder heating qE starts if the Vitoligno boiler
water temperature lies above the value selected on thermostat tQ and
the temperature in the DHW cylinder lies below the set DHW temper-
ature selected on the Vitotronic 200-H.

DHW heating with priority


After the Vitoligno starts, DHW is heated up first; central heating is
provided thereafter.
The Vitoligno boiler water temperature is at least 60 C, boiler circuit
pump 5 runs to raise the return temperature. If the temperature inside
ID: 4605017_1001_02
the DHW cylinder is below the value set on the Vitotronic 200-H, then
circulation pump for cylinder heating qE runs, if the value set at the
Applications thermostat of heating water buffer cylinder tQ is exceeded. Any
Heating system with Vitoligno 100-S and heating water buffer cylinder excess heat not required will be transferred to the heating water buffer
with one or several heating circuits with 3-way mixer and DHW heat- cylinder if the flow rate of boiler circuit pump 5 is greater than that of
ing circulation pump qE. 3-way mixer rR of the heating circuits is closed
For systems where the heat demand does not exceed 70 % of the while DHW is heated. Circulation pump qE is switched off when the
Vitoligno 100-S output. set temperature has been reached, 3-way mixer rR opens and heat is
being transferred to the heating circuit.
Main components
Vitoligno 100-S DHW heating without priority control
Return temperature raising facility To change without priority control at the Vitotronic 200-H, change code
Heating water buffer cylinder "A2" from "A2:2" to "A2:0". Depending on the prevailing demand, either
Heating circuit control unit Vitotronic 200-H DHW and/or central heating is provided when the Vitoligno starts.
DHW cylinders (optional dual mode) In that case, both circulation pumps qE and rE transfer heat from the
Solar thermal system (optional) Vitoligno and from the heating water buffer cylinder to the respective
consumer.
Function description
The boiler water temperature is regulated in accordance with the DHW heating by heating water buffer cylinder
selected set boiler temperature by adjustment of the flue gas fan The Vitoligno boiler water temperature lies below 60 C, the temper-
speed. When the minimum boiler water temperature reaches 60 C, ature in the heating water buffer cylinder lies above the value set at
boiler circuit pump 5 of the Vitoligno starts. Either the heating circuit thermostat tQ. When there is a demand for DHW heating, circulation 5
or the DHW cylinder is heated. pump for cylinder heating qE starts, and the DHW cylinder is heated
Vitoligno boiler circuit pump 5 stops when the minimum boiler water by the heating water buffer cylinder.
temperature or the flue gas temperature are not achieved.
DHW heating by the solar thermal system
Return temperature raising facility Solar circuit pump R1 wE starts and DHW cylinder qR is heated up, if
The Vitoligno requires a minimum return temperature. When boiler the temperature differential between collector temperature sensor S1
circuit pump 5 starts, mixing valve 4 opens the path from the central wQ and cylinder temperature sensor S2 qT exceeds the start temper-
heating return to the Vitoligno in line with the increasing return tem- ature differential.
perature and simultaneously closes the path from the heating flow to Pump R1 wE stops if:
the return (bypass). The actual temperature drops below the stop temperature differen-
tial
Heating the heating water buffer cylinder The electronic temperature limit (max. at 90 C) of Vitosolic 100 (type
If the minimum return temperature is exceeded and the resulting heat SD1) wZ is exceeded
yield is greater than that required by the consumers, the heating water The temperature selected at high limit safety cut-out (STB) qZ (if
buffer cylinder is heated with the help of boiler circuit pump 5. installed) is reached
Flue gas temperature limiter zE switches boiler circuit pump 5 off The requirements for the additional function are achieved through cir-
when the flue gas temperature no longer reaches its minimum tem- culation pump R2 wR.
perature. This prevents a cooling down of heating water buffer cylinder
tP.

Heating with Vitotronic 200-H


When the temperature in the DHW cylinder is above the selected set
value and there is heat demand in the heating circuits, the Vitotronic
200-H regulates the temperature level of the heating circuits with a
mixer, taking account of outside conditions. The Vitoligno or the heat-
ing water buffer cylinder supplies the heating circuits.
5822 470 GB

System examples VIESMANN 111


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605017_1001_02


--26/S1--

45 60
--41/1--

--KM-Bus--
--KM-Bus--
Vorlauf

21 40

--S2--
--S1--
20

--1--
--2--
--5--
61
--41/20M1--
26 41
Ruecklauf

42

--28--
--R2--

--21--
--R1--

--52M1--
--20M1--
--230V--

--230V--
--41/2--
22
43
--41/20M1--
44
--41/52M1--

23 ----26/R1--
WW

12 --41/28-- 53
25
--41/21--

4
3
13 -- 5
--2/X3--

--41/21--
16
--2/X4--

8
--26/R2--

7
51
24 --
--41/5-- 11 63
--2/X4--

15
--26/S2-- 9

5 KW 10 / 14 1 50
--X4--
--X4--

2
--X3--
-230V-

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605017_1001_02
Pos. Description Part no.
Heat source
1 Vitoligno 100-S with As per Viessmann pricelist
2 Boiler circuit control part of the standard delivery of pos.
1
3 Return temperature raising facility 7373 302
4 Thermostatic control valve part of the standard delivery of pos.
3
5 Boiler circuit pump KKP part of the standard delivery of pos.
3
6 Thermally activated safety valve 7143 845
7 Boiler water temperature sensor KTS part of the standard delivery of pos.
1
8 Safety equipment block with safety valve Z006 950
9 Expansion vessel As per Vitoset pricelist
DHW heating by the boiler
qP DHW cylinder As per Viessmann pricelist
5822 470 GB

qQ Cylinder temperature sensor STS 7450 633


qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist

112 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605017_1001_02
Pos. Description Part no.
DHW heating by the solar thermal system
qR Dual mode DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS 7450 633
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist
qT Cylinder temperature sensor SOL part of the standard delivery of pos.
26
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL part of the standard delivery of pos.
26
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump R1 part of the standard delivery of pos.
22
wR Circulation pump R2 (transfer) on-site
wT Automatic thermostatic mixing valve 7438 940
wZ Vitosolic 100, type SD1 Z007 387
wU Junction box on-site
rP Heating circuits with mixer
rQ Heating circuit control unit Vitotronic 200-H
Type HK1W for 1 heating circuit with mixer Z004 981
Type HK3W for 2 or 3 heating circuits with mixer Z004 983
and for every heating circuit with mixer
one extension kit each 7450 650
comprising
rW Flow temperature sensor VTS (contact sensor)
and
rR Mixer motor M2
or
rW Flow temperature sensor VTS
Contact temperature sensor 7183 288
or
Immersion temperature sensor 7450 641
and
rR Mixer motor M2 for flanged mixer and plug As per Viessmann pricelist
rE Heating circuit pump HKP M2 and 3-way mixer As per Viessmann pricelist 5
or
Divicon As per Viessmann pricelist
rT Outside temperature sensor ATS part of the standard delivery of pos.
41
tP Heating water buffer cylinder As per Viessmann pricelist
tQ Heating water buffer cylinder thermostat 7151 989
tE Connection unit, heating water buffer cylinder 7159 406
zE Flue gas temperature limiter ATW 7429 711
Accessories
zP Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
zQ Thermostat for underfloor heating system
Immersion thermostat 7151 728
Contact thermostat 7151 729
zW KM BUS distributor 7415 028
5822 470 GB

System examples VIESMANN 113


Solid fuel boiler (cont.)

Electrical installation scheme

2 X1.5 N
X1.6 230 V/ 50 Hz
X1.7 L
X3.6 N
M
X2.2 1~ KKP 5
X3.5 L

X4.4 ATW 63
X4.3
X4.2
KTS 7
X4.1

41 N
28 M ZP
1~ 12
L
N
21 M UPSB
1~ 13
L

N
M M2
52 1~ 44
230 V/ 50 Hz

61 20
L
M HKP M2
20 1~ 43
N

N
40 230 V/ 50 Hz
L

26
L 21
N 20 230 V/ 50 Hz
15
R1 19
M
N 18 1~ R1 23
14
27
5 STB 16
R2 17
62 M
N 16 1~ R2 24
13
3 3
145 2 2 145
1 1 3
145 2 12
145
1 11
4 SOL 15
S2
Low voltage

3
S1 2 KOL 21
1
3
145 2
KM BUS 60
1
3
1 2
1 ATS 45
3
5 2
1 STS 11
3
2 2
1 VTS 42

ID: 4605017_1001_02
5822 470 GB

114 VIESMANN System examples


Solid fuel boiler (cont.)

5.3 Vitoligno 100-S and oil/gas boiler, with one or several heating circuits with mixer,
heating water buffer cylinder and DHW heating (optional with dual mode DHW cylinder
and solar thermal system)
The burner of the oil/gas boiler starts and circulation pump for cylinder
heating qE runs, if the DHW cylinder temperature falls below the value
set at the cylinder thermostat of the boiler circuit control unit, subject
to the temperature in the oil/gas boiler having exceeded the value
selected on control thermostat eU (set cylinder temperature + 10 K).
3-way mixer rR in the heating circuit is closed and heating circuit pump
rE is switched off. 3-way diverter valve eE from the oil/gas boiler to
the consumers is open.

DHW heating by the Vitolig 100-S


ID: 4605018_1001_02 The Vitoligno boiler water temperature is at least 60 C; boiler circuit
pump 5 runs to raise the return temperature. If the DHW cylinder
temperature falls below the value set at the cylinder thermostat of the
Applications boiler circuit control unit, 3-way diverter valve eE opens towards the
Heating systems with Vitoligno 100-S and oil/gas boiler with one or Vitoligno and from the heating water buffer cylinder towards the con-
more heating circuits with 3-way mixer, heating water buffer cylinder sumers, circulation pump qE runs (if the temperature set at thermostat
and DHW heating. tW is exceeded) and the DHW cylinder will be heated.
For systems where the heat demand does not exceed 70 % of the After the Vitoligno starts, DHW is heated up first; central heating is
output of the standby boiler Vitoligno 100-S. provided thereafter.
3-way mixer rR of the heating circuit is closed while DHW is being
Main components heated. When the DHW temperature set at the cylinder thermostat of
Vitoligno 100-S the boiler circuit control unit has been reached, circulation pump qE
Oil/gas boilers stops, 3-way mixer rR opens and heat is transferred for central heat-
Return temperature raising facility ing.
Heating water buffer cylinder
DHW cylinders (optional dual mode) DHW heating by heating water buffer cylinder
Solar thermal system (optional) The Vitoligno boiler water temperature is below 60 C, the temperature
in the heating water buffer cylinder is lower than the value set at ther-
Function description mostat tW. 3-way diverter valve eE is open towards the Vitoligno and
The boiler water temperature is regulated in accordance with the the heating water buffer cylinder towards the consumers. Circulation
selected set boiler temperature by adjustment of the flue gas fan pump for cylinder heating qE runs and the DHW cylinder is being
speed. When the minimum boiler water temperature reaches 60 C, heated. DHW heating ends, when the temperature set at the cylinder
boiler circuit pump 5 of the Vitoligno starts. Either the heating circuit thermostat of the control unit of the oil/gas boiler has been reached. 5
or the DHW cylinder is heated. Circulation pump qE stops and 3-way diverter valve eE remains open
Vitoligno boiler circuit pump 5 stops when the minimum boiler water towards the Vitoligno and the heating water buffer cylinder towards the
temperature or the flue gas temperature are not achieved. consumers.
Circulation pump qE will also stop if the actual temperature in the
Return temperature raising facility heating water buffer cylinder falls below that set at thermostat tW. The
The Vitoligno requires a minimum return temperature. When boiler cylinder is then heated by the oil/gas boiler.
circuit pump 5 starts, mixing valve 4 opens the path from the central
heating return to the Vitoligno in line with the increasing return tem- DHW heating by the solar thermal system
perature and simultaneously closes the path from the heating flow to Solar circuit pump R1 wE starts and DHW cylinder qR is heated up, if
the return (bypass). the temperature differential between collector temperature sensor S1
wQ and cylinder temperature sensor S2 qT exceeds the start temper-
Heating the heating water buffer cylinder ature differential.
If the minimum return temperature is exceeded and the resulting heat Pump R1 wE stops if:
yield is greater than that required by the heating circuits or cylinder The actual temperature drops below the stop temperature differen-
heating, the heating water buffer cylinder is heated with the help of tial
boiler circuit pump 5. The electronic temperature limit (max. at 90 C) of Vitosolic 100
Flue gas temperature limiter zE switches boiler circuit pump 5 off wZ is exceeded
when the flue gas temperature no longer reaches its minimum tem- The temperature selected at high limit safety cut-out (STB) qZ (if
perature. This prevents a cooling down of heating water buffer cylinder installed) is reached
tP. The requirements for the additional function are achieved through cir-
culation pump R2 wR.
DHW heating
Heating mode
DHW heating by oil or gas boiler
The Vitoligno boiler water temperature is below 60 C, the temperature Heating by oil or gas boiler
in the heating water buffer cylinder is lower than the value set at ther- The burner of the oil/gas boiler is enabled if the Vitoligno boiler water
mostat tW (DHW temperature +10 K). temperature falls below 60 C and the temperature in the heating water
buffer cylinder is below the value set at thermostat tQ. 3-way diverter
valve eE is open from the oil/gas boiler to the consumers.
5822 470 GB

The control unit of the oil or gas boiler automatically adjusts the boiler
water temperature to the respective outside temperature. The heating
flow temperature is controlled by the heating circuit control unit via 3-
way mixer rR subject to outside temperature.

System examples VIESMANN 115


Solid fuel boiler (cont.)

Heating by the Vitoligno 100-S Note


If the Vitoligno boiler water temperature exceeds 60 C and if the DHW The heating and DHW heating programs must always be controlled by
cylinder is heated up, 3-way diverter valve eE opens from the Vitoligno the oil/gas boiler circuit control unit.
and the heating water buffer cylinder towards the consumers. The heat Recommended settings
created by the Vitoligno is transferred via boiler circuit pump 5 to the Temperature controller tQ: 40 to 60 C
heating circuit and to the heating water buffer cylinder. The heat not Temperature controller tW: approx. 65 C
required by the heating circuit is transferred to the heating water buffer Vitoligno 100-S and oil/gas boilers must use separate chimneys.
cylinder.
The heating circuit flow temperature is controlled by the boiler circuit Changing functions on the Vitotronic 200
control unit of the oil/gas boiler via 3-way mixer rR. Function Code
Circulation pump for cylinder heating activated 61: 1
Heating by heating water buffer cylinder irrespective of boiler water temperature
If the Vitoligno boiler water temperature falls, a greater amount of heat Circulation pump for cylinder without run-on 62: 0
is drawn from the heating water buffer cylinder, the more mixing valve
4 of the return temperature raising facility opens the path from the
heating flow to the heating return (bypass). If the boiler water temper-
ature falls below 60 C or the flue gas temperature of the Vitoligno
reaches 100 C, boiler circuit pump 5 stops and heat is only drawn
from the heating water buffer cylinder.
The heating water buffer cylinder supplies heat until the actual tem-
perature falls below the temperature set at thermostat tQ (manually
matched to the heating system return temperature, e.g. 40 C in spring
and autumn and, for example, 60 C when there is a high heat
demand). Thermostat tQ on the heating water buffer cylinder deter-
mines the required heating flow temperature. If the temperature inside
the heating water buffer cylinder falls below the value set at thermostat
tQ, 3-way diverter valve eE changes to connect the oil/gas boiler with
the consumers, the burner of the oil/gas boiler starts and heating will
be provided by that boiler.

5822 470 GB

116 VIESMANN System examples


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605018_1001_02


--26/S1--

60

--KM-Bus--
21 40

--S2--
--S1--
20
61
--31/20M2--
26 38
42

--19--
--4;5--

--6--

--7;8--
--9;10--
--22;23--
--R2--

--13;14--
--R1--

--230V--
--230V--

--11;12--
--31/2M2--
22
43
--31/20M2--
44
--31/52M2--

-38/13;14--

23 ----26/R1--
WW
I 33
---
32 II III
12 --
--31/28--

25 53
--38/19--

4
13 -- 3 5
--38/6-

--38/7;8--
--38/9;10--
16

--38/22;23--
--2/X4--

51
8
--26/R2--

--
7
------
24 -- 52 VIESMANN

--31/5-- 11 63
37
45
--2/X4--

15
--26/S2-- 9
--31/1--

50
5
KW 10 / 14 1 30
-KM-Bus-
--2M2--
--X4--

--X4--

--1--
--5--

2 31
--20M2--
--21--
--X3--

--28--

--52M2--
--230V--

--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605018_1001_02
Pos. Description Part no.
Heat source
1 Vitoligno 100-S with As per Viessmann pricelist
2 Boiler circuit control part of the standard delivery of pos.
1
3 Return temperature raising facility 7373 302
4 Thermostatic control valve part of the standard delivery of pos.
3
5 Boiler circuit pump KKP part of the standard delivery of pos.
3
6 Thermally activated safety valve 7143 845
7 Boiler water temperature sensor KTS part of the standard delivery of pos.
1
8 Safety equipment block with safety valve Z006 950
9 Expansion vessel As per Vitoset pricelist
5822 470 GB

System examples VIESMANN 117


Solid fuel boiler (cont.)

ID: 4605018_1001_02
Pos. Description Part no.
DHW heating by the boiler
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS part of the standard delivery of pos.
31
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist
DHW heating by the solar thermal system
qR Dual mode DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS part of the standard delivery of pos.
31
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist
qT Cylinder temperature sensor SOL part of the standard delivery of pos.
26
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL part of the standard delivery of pos.
26
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump R1 part of the standard delivery of pos.
22
wR Circulation pump R2 (transfer) on-site
wT Automatic thermostatic mixing valve 7438 940
wZ Vitosolic 100, type SD1 Z007 387
wU Junction box on-site
eP Oil/gas boilers As per Viessmann pricelist
with
eQ Vitotronic 200, type KW 2 or KW 5 part of the standard delivery of pos.
30
rT Outside temperature sensor ATS part of the standard delivery of pos.
31
eW Connection unit diverter valve
Connection R 1 7159 407
eE 3-way diverter valve part of the standard delivery of pos.
32
5 eR External extension H5 7199 249
eU Temperature controller 7151 989
eI Wiring chamber 7408 901
eO Contactor relay 7814 681
rP Heating circuits
rQ Extension kit for one heating circuit with mixer 7450 650
comprising
rW Flow temperature sensor VTS M2 (contact sensor)
and
rR Mixer motor M2
or
rW Flow temperature sensor VTS M2
Contact temperature sensor 7183 288
or
Immersion temperature sensor 7450 641
and
rR Mixer motor M2 for flanged mixer and plug As per Viessmann pricelist
rE Heating circuit pump HKP M2 and 3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
for further heating circuits with mixer, a Vitotronic 200-H is required As per Viessmann pricelist
tP Heating water buffer cylinder As per Viessmann pricelist
tQ Heating water buffer cylinder thermostat 7151 989
tW Heating water buffer cylinder thermostat 7151 989
tE Connection unit, heating water buffer cylinder 7159 406
zE Flue gas limiter ATW 7429 711
5822 470 GB

118 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605018_1001_02
Pos. Description Part no.
Accessories
zP Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
zQ Thermostat for underfloor heating system
Immersion thermostat 7151 728
Contact thermostat 7151 729
zW KM BUS distributor 7415 028

5
5822 470 GB

System examples VIESMANN 119


Solid fuel boiler (cont.)

Electrical installation scheme

2 X1.5 N
X1.6 230 V / 50 Hz
X1.7 L
X3.6 N A1 4
X2.2 39 38
X3.5 L A2 5

X4.4 ATW 63
X4.3
X4.2
KTS 7
X4.1

31 N
28 M ZP
1~ 12
L
N 12
21 38
L 11

N
M M2
52 1~ 44
230 V / 50 Hz

61 20
L
M HKP M2
20 1~ 43
N

N
40 230 V / 50 Hz A
L

34 TR 2
150 38
TR 3
7
41
7
41 41 26
X12 2 L 21
X12
N 20 230 V / 50 Hz
5 15
R1 19
M
N 18 1~ R1 23
14
27
STB 16
R2 17
62 M
N 16 1~ R2 24
13
3 3
145 2 2 145
1 1 3
145 2 12
145
1 11
4 SOL 15
S2
3
S1 2 KOL 21
Low voltage

1
3
145 2
KM BUS 60
1
3
1 2
1 ATS 45
3
5 2
1 STS 11
3
2 2
1 VTS M2 42

ID: 4605018_1001_02
5822 470 GB

120 VIESMANN System examples


Solid fuel boiler (cont.)

38
25

24
23
37
3 1
22
21

20
N
M UPSB
1~ 13
19
18

17
16

15
N
M 33
14 1~
13
12 N
21 31
11 L
10
2 1 52
9

8
3 1 51
7

N
M KKP 5
1~
6
5
39
4

3 TR
150 34
2 TR
5
N
230 V/ 50 Hz A
1

N
230 V/ 50 Hz B
L

ID: 4605018_1001_02

A Power supply
B Power supply for the oil/gas boiler circuit control unit
5822 470 GB

System examples VIESMANN 121


Solid fuel boiler (cont.)

5.4 Vitoligno 100-S and wall mounted oil or gas boiler, with one or several heating circuits
with mixer, heating water buffer cylinder and DHW heating (optional with dual mode DHW
cylinder and solar thermal system)
The burner of the wall mounted oil/gas boiler starts and circulation
pump for cylinder heating qE runs, if the DHW cylinder temperature
falls below the value set at the cylinder thermostat of the boiler circuit
control unit, subject to the temperature in the wall mounted oil/gas
boiler having exceeded the value selected on thermostat eU (set cyl-
inder temperature + 10 K). 3-way mixer rR in the heating circuit is
closed and heating circuit pump rE is switched off. 3-way diverter
valve eE from the wall mounted oil/gas boiler to the consumers is
open.

ID: 4605019_1001_02 DHW heating by the Vitoligno 100-S


The Vitoligno boiler water temperature is at least 60 C; boiler circuit
pump 5 runs to raise the return temperature. If the DHW cylinder
Applications temperature falls below the value set at the cylinder thermostat of the
Heating systems with Vitoligno 100-S and wall mounted oil/gas boiler boiler circuit control unit, 3-way diverter valve eE opens towards the
with one or several heating circuits with 3-way mixer, heating water Vitoligno and from the heating water buffer cylinder towards the con-
buffer cylinder and DHW heating. sumers, circulation pump qE runs (if the temperature set at thermostat
For systems where the heat demand does not exceed 70 % of the tW is exceeded) and the DHW cylinder will be heated.
output of the standby boiler Vitoligno 100-S. After the Vitoligno starts, DHW is heated up first; central heating is
provided thereafter.
Main components 3-way mixer rR of the heating circuit is closed while DHW is being
Vitoligno 100-S heated. When the DHW temperature set at the cylinder thermostat of
Oil or gas wall mounted boiler the boiler circuit control unit has been reached, circulation pump qE
Return temperature raising facility stops, 3-way mixer rR opens and heat is enabled for central heating.
Heating water buffer cylinder
DHW cylinders (optional dual mode)
Solar thermal system (optional) DHW heating by heating water buffer cylinder
The Vitoligno boiler water temperature is below 60 C, the temperature
Function description in the heating water buffer cylinder is lower than the value set at ther-
The boiler water temperature is regulated in accordance with the mostat tW. 3-way diverter valve eE is open towards the Vitoligno and
selected set boiler temperature by adjustment of the flue gas fan the heating water buffer cylinder towards the consumers. Circulation
speed. When the minimum boiler water temperature reaches 60 C, pump for cylinder heating qE runs and the DHW cylinder is being
5 boiler circuit pump 5 of the Vitoligno starts. Either the heating circuit heated. DHW heating ends, when the temperature set at the cylinder
or the DHW cylinder is heated. thermostat of the control unit of the wall mounted oil/gas boiler has
Vitoligno boiler circuit pump 5 stops when the minimum boiler water been reached. Circulation pump qE stops and 3-way diverter valve
temperature or the flue gas temperature are not achieved. eE remains open towards the Vitoligno and the heating water buffer
cylinder towards the consumers.
Return temperature raising facility Circulation pump qE will also stop if the actual temperature in the
The Vitoligno requires a minimum return temperature. When boiler heating water buffer cylinder falls below that set at thermostat tW. The
circuit pump 5 starts, mixing valve 4 opens the path from the central cylinder is then heated by the wall mounted oil/gas boiler.
heating return to the Vitoligno in line with the increasing return tem-
perature and simultaneously closes the path from the heating flow to DHW heating by the solar thermal system
the return (bypass). Solar circuit pump wE starts and DHW cylinder qR is heated up, if the
temperature differential between collector temperature sensor wQ and
Heating the heating water buffer cylinder cylinder temperature sensor qT exceeds the start temperature differ-
If the minimum return temperature is exceeded and the resulting heat ential.
yield is greater than that required by the heating circuits or cylinder The pump wE stops if:
heating, the heating water buffer cylinder is heated with the help of The actual temperature drops below the stop temperature differen-
boiler circuit pump 5. tial
Flue gas temperature limiter zE switches boiler circuit pump 5 off The electronic temperature limit (max. at 90 (max. 90C) of the solar
when the flue gas temperature no longer reaches its minimum tem- control unit (type SM1) wZ is exceeded
perature. This prevents a cooling down of heating water buffer cylinder The temperature selected at high limit safety cut-out (STB) qZ (if
tP. installed) is reached
The requirements for the additional function are achieved through cir-
DHW heating culation pump wR.

DHW heating by the wall mounted oil/gas boiler Heating mode


The Vitoligno boiler water temperature is below 60 C, the temperature
in the heating water buffer cylinder is lower than the value set at ther- Heating by wall mounted oil/gas boiler
mostat tW (DHW temperature + 10 K). The burner of the wall mounted oil/gas boiler is enabled if the Vitoligno
boiler water temperature falls below 60 C and the temperature in the
heating water buffer cylinder is below the value set at thermostat tQ.
5822 470 GB

3-way diverter valve eE from the wall mounted oil/gas boiler to the
consumers is open.

122 VIESMANN System examples


Solid fuel boiler (cont.)

The control unit of the wall mounted oil/gas boiler automatically adjusts The heating water buffer cylinder supplies heat until the actual tem-
the boiler water temperature to the respective outside temperature. perature falls below the temperature set at thermostat tQ (manually
The heating flow temperature is controlled by the heating circuit control matched to the heating system return temperature, e.g. 40 C in spring
unit via 3-way mixer rR subject to outside temperature. and autumn and, for example, 60 C when there is a high heat
demand). Thermostat tQ on the heating water buffer cylinder deter-
Heating by the Vitoligno 100-S mines the required heating flow temperature. If the temperature inside
If the Vitoligno boiler water temperature exceeds 60 C and if the DHW the heating water buffer cylinder falls below the value set at thermostat
cylinder is heated up, 3-way diverter valve eE opens from the Vitoligno tQ, 3-way diverter valve eE changes to connect the wall mounted oil/
and the heating water buffer cylinder towards the consumers. The heat gas boiler with the consumers, the burner of the wall mounted oil/gas
created by the Vitoligno is transferred via boiler circuit pump 5 to the boiler starts and heating will be provided by that boiler.
heating circuit and to the heating water buffer cylinder. The heat not
required by the heating circuit is transferred to the heating water buffer Note
cylinder. The heating and DHW heating functions must always be controlled by
The heating circuit flow temperature is controlled by the boiler circuit the control unit of the wall mounted oil/gas boiler.
control unit of the wall mounted oil/gas boiler via 3-way mixer rR. Recommended settings
Temperature controller tQ: 40 to 60 C
Heating by heating water buffer cylinder Temperature controller tW: approx. 65 C
If the Vitoligno boiler water temperature falls, a greater amount of heat Vitoligno100-S and wall mounted oil/gas boilers must be connected to
is drawn from the heating water buffer cylinder, the more mixing valve separate chimney stacks.
4 of the return temperature raising facility opens the path from the
heating flow to the heating return (bypass). If the boiler water temper-
ature falls below 60 C or the flue gas temperature of the Vitoligno
reaches 100 C, boiler circuit pump 5 stops and heat is only drawn
from the heating water buffer cylinder.

5
5822 470 GB

System examples VIESMANN 123


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605019_1001_02

60
--26/6--

34

--A1--

--A2--
--KM-Bus--
--40--
--DE1-
--KM-Bus--

-KM-Bus-
--2M2--
21 40
20
--5--
--6--
61
-41/20M2--
26 38 41
42

--6--

--7;8--

--22;23--
--19--
--4;5--
--24;25--

--9;10--

--40--
--13;14--

--52M2--
--20M2--
--230V--
--230V--

--11;12--
--22--
--24--

-41/2M2--
22
43
--41/20M2--
44
-38/13;14- --41/52M2--

36
23 ----26/24-- 37 --31/X3.4;3.5--
WW I 33 --38/22;23--
---
III
32 II

--34/A1-- 35
12
25
53
--38/19--

4
13 --
3 5

--38/7;8--
--38/6-

--38/9;10--
16
51
-2/X4-
--26/22--

VIESMANN
--
7
------
24 -- 8 52 45
--31/5-- 11
-31/X3.1;3.2-

63
15 30
--26/5-- 9
--2/X4--

--X3.4;3.5--

5
--X3.1;3.2--
--KM-Bus--

KW 10 / 14 1 50
--X4--
--X4--

--5--

2 31
--96--
-230V-

-230V-

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605019_1001_02
Pos. Description Part no.
Heat source
1 Vitoligno 100-S with As per Viessmann pricelist
2 Boiler circuit control unit part of the standard delivery of pos.
1
3 Return temperature raising facility 7373 302
4 Thermostatic control valve part of the standard delivery of pos.
3
5 Boiler circuit pump KKP part of the standard delivery of pos.
3
6 Thermally activated safety valve 7143 845
7 Boiler water temperature sensor KTS part of the standard delivery of pos.
1
8 Safety equipment block with safety valve Z006 950
9 Expansion vessel As per Vitoset pricelist
DHW heating by the boiler
5822 470 GB

qP DHW cylinder As per Viessmann pricelist


qQ Cylinder temperature sensor STS 7179 114
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist

124 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605019_1001_02
Pos. Description Part no.
DHW heating by the solar thermal system
qR Dual mode DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS 7179 114
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Viessmann pricelist
qT Cylinder temperature sensor SOL part of the standard delivery of pos.
26
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL part of the standard delivery of pos.
26
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump part of the standard delivery of pos.
22
wR Circulation pump (transfer) on-site
wT Automatic thermostatic mixing valve 7438 940
wZ Solar control module, type SM1 7429 073
wU Junction box on-site
eP Oil or gas wall mounted boiler As per Viessmann pricelist
with
eQ Vitotronic 200, type HO1A part of the standard delivery of pos.
30
rT Outside temperature sensor ATS part of the standard delivery of pos.
31
eW Connection unit diverter valve
Connection R 1 7159 407
Connection R 1 7159 408
eE 3-way diverter valve part of the standard delivery of pos.
32
System without DHW circulation:
zR Internal extension H1 7179 057
or
zT Internal extension H2 7179 144
System with DHW circulation or with the Vitoladens 300-W additionally:
eR Extension AM1 7429 152
zZ Extension EA1 7429 151 5
eT Low loss header 7148 100
eZ Flow temperature sensor VTS for low loss header 7179 488
eU Temperature controller 7151 989
eI Wiring chamber 7408 901
eO Contactor relay 7814 681
rP Heating circuits
rQ Extension kit for one heating circuit with mixer 7301 063
comprising
rW Flow temperature sensor VTS M2 (contact temperature sensor)
and
rR Mixer motor M2
or
rQ Extension kit for one heating circuit with mixer 7301 062
rW Flow temperature sensor VTS M2 part of the standard delivery of pos.
41
rR Mixer motor M2 for flanged mixer and plug
rE Heating circuit pump M2 and 3-way mixer As per Viessmann pricelist
or
Divicon As per Viessmann pricelist
for further heating circuits with mixer, a Vitotronic 200-H is required As per Viessmann pricelist
tP Heating water buffer cylinder As per Viessmann pricelist
tQ Heating water buffer cylinder thermostat 7151 989
tW Heating water buffer cylinder thermostat 7151 989
tE Connection unit, heating water buffer cylinder 7159 406
zE Flue gas limiter ATW 7429 711
5822 470 GB

System examples VIESMANN 125


Solid fuel boiler (cont.)

ID: 4605019_1001_02
Pos. Description Part no.
Accessories
zP Vitotrol 200A Z008 341
or
Vitotrol 300A Z008 342
zQ Thermostat for underfloor heating system
Immersion thermostat 7151 728
Contact thermostat 7151 729
zW KM BUS distributor 7415 028

5822 470 GB

126 VIESMANN System examples


Solid fuel boiler (cont.)

Electrical installation scheme

2 X1.5 N
X1.6 230 V / 50 Hz
X1.7 L
X3.6 N A1 4
X2.2 39 38
X3.5 L A2 5

X4.4 ATW 63
X4.3
X4.2
KTS 7
X4.1

64
31
31 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
53 L
L
96 96 64 65 1
N
N
28 M
1~ ZP 12
40 66 L

65

31 L
96
5 STS 11 96 N

X3.7 P
X3.6 157
S
X3.5 VTS 36
X3.4
Low voltage

N
28 M
X3.3 1~ ZP 12
L

X3.2
ATS 45 62
X3.1
3 5
2 145
1 3
145 2
KM BUS 60
1
3
145 2
1

66

31 N
40
96 L
N
40A 40 34
L
P
157

S

4
0-10V
3
2 24
DE1 38
1 25
2 2
145 145 34
1 1

ID: 4605019_1001_02
5822 470 GB

System examples VIESMANN 127


Solid fuel boiler (cont.)

34
66
N
40A 40
L
N
40A 40 41
L
N
A1 M
1~ ZP 12
L
N 11
A2 38
L 12
66
2 2
145 145
1 1

41
34
N
40A 40
L N
40A 40 26
L
42
N
M HKP 43
20 1~ M2
L

N
52 M M2
1~ 44

2
2 1 VTS M2 42

2 2
145
1 1

5 41
26

N
40A 40
L
N
24 M
1~ 23
L
27
STB 16
N
22 M
1~ 24
L
2
PWM
1
4
6 KOL 21
3
2
5 SOL 15
1
2
1 145

ID: 4605019_1001_02
5822 470 GB

128 VIESMANN System examples


Solid fuel boiler (cont.)

38
25
DE1 66
24
23
37
3 1
22
21

20
N
M UPSB
1~ 13
19
18

17
16

15
N
M 33
14 1~
13
12 N
A2 34
11 L
10
2 1 52
9

8
3 1 51
7

N
M KKP 5
1~
6
5
39
4

3
2

N
5
230 V / 50 Hz A
1

N
230 V / 50 Hz B
L

ID: 4605019_1001_02

A Power supply
B Power supply for the boiler circuit control unit of the wall mounted
oil/gas boiler
5822 470 GB

System examples VIESMANN 129


Solid fuel boiler (cont.)

5.5 Vitoligno 100-S with oil or gas boiler, one or several heating circuits with mixer, heating
water buffer cylinder and DHW heating with multi-mode heating water buffer cylinder
The entire top section of Vitocell 340-M/360-M qR is heated, thereby
also providing the DHW heating.

Central heating by boiler and solar energy


3-way diverter valve zR is switched to position "AB-A" if a temperature
differential greater than differential temperature 2 set on Vitosolic 200
(type SD4) wZ is captured between temperature sensor qU and heat-
ing circuit return temperature sensor zE. The heating return water is
routed via Vitocell 340-M/360-M qR to boiler eP. If the temperature of
the preheated return water is too low, boiler eP reheats the water to
ID: 4605020_1001_02 the required flow temperature.

DHW heating without solar energy


Applications The top section of Vitocell 340-M/360-M qR is heated by boiler eP. The
Heating system with Vitoligno 100-S and oil/gas boiler with one or more integral instantaneous water heater/standby section is heated by the
heating circuits with 3-way mixer, heating water buffer cylinder and surrounding buffer cylinder water. The DHW control thermostat with
DHW heating connected cylinder temperature sensor qQ of boiler circuit control unit
eQ of boiler eP switches circulation pump for cylinder heating qE.
Main components
Vitoligno 100-S DHW heating with solar energy
Oil/gas boilers If a temperature differential greater than differential temperature 1 set
Return temperature raising facility on Vitosolic 200 (type SD4) wZ is captured between collector temper-
Heating water buffer cylinder ature sensor wQ and cylinder temperature sensor qT, then solar circuit
Heating water buffer cylinder with integral DHW heating Vitocell 340- pump wE starts, and Vitocell 340-M/360-M qR will be heated. During
M/360-M this process, the temperature inside the Vitocell 340-M/360-M will be
Solar thermal system (optional) restricted by the electronic temperature limiter in the Vitosolic 200 (type
SD4) wZ.
Function description This stops solar circuit pump wE when the actual temperature falls
below the set temperature. The electronic temperature limiter is preset
Combustion controller and control of the Vitoligno circulation at the factory to 60 C and can be adjusted. If there is sufficient inso-
pump lation for DHW heating, then the entire contents of the Vitocell 340-M/
Vitoligno boiler circuit pump 5 starts when a boiler water temperature 360-M will be heated by the solar thermal system. The boiler only
of 60 C has been reached. Either the heating circuit or the DHW cyl- reheats the top section of the Vitocell 340-M/360-M, if the set temper-
inder is heated. The heat not drawn off by consumers is transferred to ature selected on the boiler circuit control unit is not achieved. If there
5 the heating water buffer cylinder. is insufficient insolation, the DHW in the lower section of the
If the Vitocell 340-M/360-M or the heating water buffer cylinder is Vitocell 340-M/360-M will be preheated, whilst the top section is heated
heated up and the boiler water temperature is below that at the bottom to the required temperature by the boiler.
of the buffer cylinder TPU + 5 K) at sensor qU, Vitoligno boiler circuit
pump 5 is switched off by the differential temperature control unit. Safety instructions
When temperatures exceed 60 C, limit the DHW temperature to
Return temperature raising facility 60 C by installing a mixing device, e.g. a thermostatic mixing valve
The Vitoligno requires a minimum return temperature. When boiler (accessory). The mixing device does not prevent the risk of scalding
circuit pump 5 starts, mixing valve 4 opens the path from the central at the draw-off point. The installation of a mixer tap at the draw-off point
heating return to the Vitoligno in line with the increasing return tem- is essential.
perature and simultaneously closes the path from the heating flow to
the heating return (bypass). Note
Vitoligno 100-S and oil/gas boilers must use separate chimneys.
Heating the heating water buffer cylinder
If the minimum return temperature is exceeded and the resulting heat Changing functions on the Vitotronic 200
yield is greater than that required by the consumers, the heating water Function Code
buffer cylinder is heated with the help of boiler circuit pump 5. Circulation pump for cylinder heating activated 61: 1
Flue gas temperature limiter zE switches boiler circuit pump 5 off irrespective of boiler water temperature
when the flue gas temperature no longer reaches its minimum tem-
perature. This prevents a cooling down of heating water buffer cylinder
tP.

Heating by the Vitoligno


If the boiler water temperature of Vitoligno 1 exceeds 60 C, the heat
generated by Vitoligno 1 is transferred by boiler circuit pump 5 to
Vitocell 340-M/360-M qRor to heating water buffer cylinder tP.
5822 470 GB

130 VIESMANN System examples


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605020_1001_02


--26/S1--

60

--KM-Bus--
21 40

--S2--
--S5--
--S1--

--S6--
20 61
-31/20M2-
26 42

--R6--
--R1--
--31/2M2--

--230V--
22
43
--31/20M2--

44
--31/52M2--
-26/S6-
63
AB
B
64 A
23 ----26/R1-

--26/R6---
WW

12 --
--31/28--

13 --
4
--31/21--

25 3 5
--2/X3--
16
-26/R1- HV1

--2/X4--
WW/Z 8
11
SPR1 18 7
-31/5-
17 HV2/HR1
-26/S5- SPR2
HR2 63
15 45
SPR3 HR3
--2/X4--

-26/S2-
KW

--31/1--
9
E
HVs/HRs

14 50 1 30

-KM-Bus-
5

--2M2--
--X4--
--X4--

KW

--1--
--5--

2 31
--21--
--28--
--X3--

--20M2--
--52M2--
--230V--

--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605020_1001_01
Pos. Description Part no.
Heat source
1 Vitoligno 100-S with see pricelist
2 Boiler circuit control unit part of the standard delivery
of pos. 1
3 Return temperature raising facility 7373 302
4 Thermostatic control valve part of the standard delivery
of pos. 3
5 Boiler circuit pump KKP part of the standard delivery
of pos. 3
6 Thermally activated safety valve 7143 845
7 Boiler water temperature sensor KTS part of the standard delivery
of pos. 1
8 Safety equipment block with safety valve Z006 950
9 Expansion vessel As per Vitoset pricelist
5822 470 GB

System examples VIESMANN 131


Solid fuel boiler (cont.)

ID: 4605020_1001_01
Pos. Description Part no.
qR Vitocell 340-M/360-M As per Viessmann pricelist
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB 7339 467
qQ Cylinder temperature sensor STS part of the standard delivery
of pos. 31
qT Cylinder temperature sensor SOL part of the standard delivery
of pos. 26
qZ High limit safety cut-out STB Z001 889
qU Buffer temperature sensor S5 Standard delivery, pos. 26
qI Threaded DHW circulation fitting 7198 542
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL part of the standard delivery
of pos. 26
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump R1 part of the standard delivery
of pos. 22
wT Automatic thermostatic mixing valve 7438 940
wZ Vitosolic 200, type SD4 Z007 388
wU Junction box on-site
eP Oil/gas boilers with
eQ Vitotronic 200, type KW2 or KW5 see pricelist
rT Outside temperature sensor ATS part of the standard delivery
of pos. 31
rP Heating circuits
rQ Extension kit for one heating circuit with mixer 7450 650
comprising
rW Flow temperature sensor VTS M2 (contact temperature sensor)
and
rR Mixer motor DN 20 to 50, R to R1
or
rW Flow temperature sensor VTS M2 (contact temperature sensor)
Contact temperature sensor or 7183 288
Immersion temperature sensor 7450 641
and
rR Mixer motor M2 for flanged mixer and plug-in connector As per Viessmann pricelist
5 rE Heating circuit pump HKP M2 As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
for further heating circuits with mixer, a Vitotronic 200-H is required As per Viessmann pricelist
tP Heating water buffer cylinder As per Viessmann pricelist
zE Flue gas temperature limiter ATW 7429 711
Accessories
zP Vitotrol 200A Z008 341
or
Vitotrol 300A Z008 342
zQ Thermostat for underfloor heating system (optional)
Immersion thermostat 7151 728
System thermostat 7151 729
zE Return temperature sensor RLS S6 (heating circuit) 7426 247
zR 3-way diverter valve R6 7814 924
zW KM BUS distributor 7415 028
5822 470 GB

132 VIESMANN System examples


Solid fuel boiler (cont.)

Electrical installation scheme

2 X1.5 N
X1.6 230 V/ 50 Hz
X1.7 L
X3.6 N
M
X2.2 1~ KKP 5
X3.5 L

X4.4 ATW 63
X4.3
X4.2
KTS 7
X4.1

31 N
28 M ZP
1~ 12
L
N
21 M UPSB
1~ 13
L

N
M M2
52 1~ 44
230 V/ 50 Hz

61 20
L
M HKP M2
20 1~ 43
N

N
40 230 V/ 50 Hz
L

26
L
230 V/ 50 Hz
N
R1
M
N 1~ R1 23
27
STB 16 5
R6
M
N 1~ R6 64

S6 RLS 63

S5 STS 17
62

3 3 SOL 15
Low voltage

S2
145 2 2 145
1 1 S1 KOL 21
3
145 2 12
145
1 11

3
145 2
KM BUS 60
1
3
1 2
1 ATS 45
3
5 2
1 STS 11
3
2 2
1 VTS M2 42

ID: 4605020_1001_02
5822 470 GB

System examples VIESMANN 133


Solid fuel boiler (cont.)

5.6 Vitoligno 100-S with wall mounted oil or gas boiler, one or several heating circuits with
mixer, heating water buffer cylinder and DHW heating with multi-mode heating water buf-
fer cylinder
Heating by the Vitoligno
If the Vitoligno boiler water temperature exceeds 60 C, the heat gen-
erated by the Vitoligno will be transferred by boiler circuit pump 5 to
the Vitocell 340-M/360-M or to the heating water buffer cylinder.
The Vitocell 340-M/360-M is heated throughout the top section,
thereby also heating DHW.

Central heating by wall mounted boiler and solar energy


3-way diverter valve zR is switched to position "AB-A" if a temperature
differential greater than differential temperature 2 set on the solar con-
trol module (type SM1) wZ is captured between temperature sensor
ID: 4605078_1001_02
qU and heating circuit return temperature sensor zE. The heating
return water is routed via Vitocell 340-M/360-M qR to wall mounted
Applications boiler eP (via low loss header eT). If the temperature of the preheated
Heating system with Vitoligno 100-S and wall mounted oil/gas boiler return water is too low, wall mounted boiler eP reheats it to the required
with one or several heating circuits with 3-way mixer, heating water flow temperature.
buffer cylinder and DHW heating
DHW heating without solar energy
Main components The top section of Vitocell 340-M/360-M qR is heated by wall mounted
Vitoligno 100-S boiler eP. The integral instantaneous water heater/standby section is
Oil or gas wall mounted boiler heated by the surrounding buffer cylinder water. The cylinder thermo-
Return temperature raising facility stat with connected cylinder temperature sensor qQ of wall mounted
Heating water buffer cylinder boiler circuit control unit eP switches circulation pump for cylinder
Heating water buffer cylinder with integral DHW heating Vitocell 340- heating qE.
M/360-M
Solar thermal system (optional) DHW heating with solar energy
If a temperature differential greater than differential temperature 1 set
Function description on solar control module (type SM1) wZ is captured between collector
temperature sensor wQ and cylinder temperature sensor qT, then solar
Combustion controller and control of the Vitoligno circulation circuit pump wE starts, and Vitocell 340-M/360-M qR will be heated.
pump During this process, the temperature inside the Vitocell 340-M/360-M
Vitoligno boiler circuit pump 5 starts when a boiler water temperature will be restricted by the electronic temperature limiter in solar control
5 of 60 C has been reached. Either the heating circuit or the module (type SM1) wZ.
Vitocell 340-M/360-M will be heated. The heat not drawn off by con- This stops solar circuit pump wE when the actual temperature falls
sumers is transferred to the heating water buffer cylinder. below the set temperature. The electronic temperature limiter is preset
If the Vitocell 340-M/360-M or the heating water buffer cylinder is at the factory to 60 C and can be adjusted. If there is sufficient inso-
heated up and the boiler water temperature is below that at the bottom lation for DHW heating, then the entire contents of the Vitocell 340-M/
of the buffer cylinder (TPU + 5 K) at sensor qU, Vitoligno boiler circuit 360-M will be heated by the solar thermal system. The wall mounted
pump 5 is switched off by the differential temperature control. boiler only reheats the top section of the Vitocell 340-M/360-M, if the
set temperature selected on the boiler circuit control unit is not ach-
Return temperature raising facility ieved. If there is insufficient insolation, the DHW in the lower section
The Vitoligno requires a minimum return temperature. When boiler of the Vitocell 340-M/360-M will be preheated, whilst the top section is
circuit pump 5 starts, mixing valve 4 opens the path from the central heated to the required temperature by the wall mounted boiler.
heating return to the Vitoligno in line with the increasing return tem-
perature and simultaneously closes the path from the heating flow to Safety instructions
the heating return (bypass). When temperatures exceed 60 C, limit the DHW temperature to
60 C by installing a mixing device, e.g. a thermostatic mixing valve
Heating the heating water buffer cylinder (accessory for DHW cylinders). The mixing device does not prevent
If the minimum return temperature is exceeded and the resulting heat the risk of scalding at the draw-off point. The installation of a mixer tap
yield is greater than that required by the consumers, the heating water at the draw-off point is essential.
buffer cylinder is heated with the help of boiler circuit pump 5.
Flue gas temperature limiter zE switches boiler circuit pump 5 off Note
when the flue gas temperature no longer reaches its minimum tem- Vitoligno 100-S and wall mounted oil/gas boilers must use separate
perature. This prevents a cooling down of heating water buffer cylinder chimneys.
tP.
5822 470 GB

134 VIESMANN System examples


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605078_1001_02


--26/6--

60

--KM-Bus--

--KM-Bus--
21 40

--10--
20

--2--
--5--
--7--
--6--
61
--41/20M2--
26 41 42

--40--
--52--
--20--
--41/2M2--

--230V--
--22--
--24--

22
43
--41/20M2--

--26/10--
44
--41/52M2--
63

B AB
64 A
23 ----26/24-

--26/22---
WW

12 -- 36
--34/A2--

13 -- -31/X3.4;3.5-
4
--34/A1--

25 3 5
--2/X3--
16 35
-26/24- HV1 45

--2/X4--
WW/Z 8
11

--31/X3.1;3.2--
-31/5- SPR1 18 7
17 HV2/HR1
--26/7-- SPR2
HR2
63
15
--26/5-- SPR3 HR3
30
--2/X4--

KW 9
E
HVs/HRs

--X3.1;3.2--
--X3.4;3.5--
--KM-Bus--
14 50 1
--A1--

--X4--

--X4--

5
--40--
--A2-

--5--
KW
34 2 31
--96--
--X3--

-230V-
-230V-

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605078_1001_02
Pos. Description Part no.
Heat source
1 Vitoligno 100-S with see pricelist
2 Boiler circuit control unit part of the standard delivery
of pos. 1
3 Return temperature raising facility 7373 302
4 Thermostatic control valve part of the standard delivery
of pos. 3
5 Boiler circuit pump KKP part of the standard delivery
of pos. 3
6 Thermally activated safety valve 7143 845
7 Boiler water temperature sensor KTS part of the standard delivery
of pos. 1
8 Safety equipment block with safety valve Z006 950
9 Expansion vessel As per Vitoset pricelist
5822 470 GB

System examples VIESMANN 135


Solid fuel boiler (cont.)

ID: 4605078_1001_02
Pos. Description Part no.
qR Vitocell 340-M/360-M As per Viessmann pricelist
qQ Cylinder temperature sensor STS 7179 114
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB 7339 467
qT Cylinder temperature sensor SOL Standard delivery, pos. 26
qZ High limit safety cut-out STB Z001 889
qU Buffer cylinder temperature sensor 7438 702
qI Threaded DHW circulation fitting 7198 542
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL part of the standard delivery
of pos. 26
wW Solar-Divicon 7188 391 or 7188 392
wE Solar circuit pump part of the standard delivery
of pos. 22
wT Automatic thermostatic mixing valve 7438 940
wZ Solar control module, type SM1 7429 073
wU Junction box on-site
eP Wall mounted oil/gas boiler with
eQ Vitotronic 200, type HO1A part of the standard delivery
of pos. 30
rT Outside temperature sensor ATS part of the standard delivery
of pos. 31
System without DHW circulation:
zR Internal extension H1 7179 057
or
zT Internal extension H2 7179 144
System with DHW circulation or with the Vitoladens 300-W additionally:
eR Extension AM1 7429 152
eT Low loss header As per Viessmann pricelist
eZ Flow temperature sensor VTS for low loss header 7179 488
rP Heating circuits
rQ Extension kit for one heating circuit with mixer 7301 063
comprising
rW Flow temperature sensor VTS M2 (contact temperature sensor)
and
5 rR Mixer motor DN 20 to 50, R to R1
or
rQ Extension kit for one heating circuit with mixer with 7301 062
rW Flow temperature sensor VTS M2 (contact temperature sensor)
and
rR Mixer motor M2 for flanged mixer and plug-in connector As per Viessmann pricelist
rE Heating circuit pump HKP M2 As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
for further heating circuits with mixer, a Vitotronic 200-H is required As per Viessmann pricelist
tP Heating water buffer cylinder As per Viessmann pricelist
zE Flue gas temperature limiter ATW 7429 711
Accessories
zP Vitotrol 200A Z008 341
or
Vitotrol 300A Z008 342
zQ Thermostat for underfloor heating system (optional)
Immersion thermostat 7151 728
System thermostat 7151 729
zE Return temperature sensor RLS (heating circuit) 7438 702
zR 3-way diverter valve 7814 924
zW KM BUS distributor 7415 028
5822 470 GB

136 VIESMANN System examples


Solid fuel boiler (cont.)

Electrical installation scheme

2 X1.5 N
X1.6 230 V / 50 Hz
X1.7 L
X3.6 N
M
X2.2 1~ KKP 5
X3.5 L

X4.4 ATW 63
X4.3
X4.2
KTS 7
X4.1

64
31
31 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
53 L
L
96 96 64 65 1
N
N
28 M
1~ ZP 12 USPB 13
40 34 L

65

31 L
96
5 STS 11 96 N

X3.7 P
X3.6 157
S
X3.5 VTS 36
X3.4 N
Low voltage

28 M USPB 13
X3.3 1~ ZP 12
L

X3.2
ATS 45 62
X3.1
3
2 145 5
1 3
145 2
KM BUS 60
1
3
145 2
1

34
31
N
40A 40
L
N
40A 40 41
L
N
A1 M UPSB 13
1~
L
N
A2 M ZP
1~ 12
L

2 2
145 145 41
1 1

ID: 4605078_1001_02
5822 470 GB

System examples VIESMANN 137


Solid fuel boiler (cont.)

41
34
N
40A 40
L N
40A 40 26
L
61
N
M HKP 43
20 1~ M2
L

N
52 M M2
1~ 44

2
2 1 VTS M2 42

34
2 2
145 145
1 1

26
41
N
40A 40
L
N
24 M
1~ 23
L
27
STB 16
N
22 M
1~ 64
L
2
PWM
1
4
10 RLS 63
3
2
7 STS 17
1
4
5 6
3
KOL 21
2
5 SOL 15
1
2
1 145

ID: 4605078_1001_02

5822 470 GB

138 VIESMANN System examples


Solid fuel boiler (cont.)

5.7 Vitolig 200 with one or two heating circuits with mixer, heating water buffer cylinder
and DHW cylinder
DHW heating with priority
After the Vitolig starts, DHW is heated up first; central heating is pro-
vided thereafter.
The Vitolig boiler water temperature is at least 60 C; boiler circuit
pump 3 runs to raise the return temperature. Circulation pump for
cylinder heating 5 runs if the DHW cylinder temperature falls below
the value set at the remote control unit of the heating circuit control unit
and the value recorded by temperature sensor qE of the heating water
buffer cylinder is 10 K higher than that of the DHW cylinder. Any sur-
plus heat will be transferred to the heating water buffer cylinder if the
ID: 4605021_1001_03 flow rate of circulation pump 3 is higher than that of circulation pump
5. 3-way mixer 8 of the heating circuit is closed while DHW is
heated. Circulation pump 5 is switched off when the set temperature
Function description has been reached, 3-way mixer 8 opens, transferring heat into the
heating circuit.
Note
The temperatures stated in the sample application are standard val- DHW heating without priority control
ues; set alternative values according to specific requirements. Set DIP switch "S2" on the heating circuit controller to "OFF" to prevent
The heating circuits and a DHW cylinder are heated by the Vitolig and a DHW priority. Depending on the prevailing demand, either DHW and/
a heating water buffer cylinder. or central heating is provided when the Vitolig starts up. In that case,
both circulation pumps 5 and 7 transfer heat from the Vitolig and
Combustion controller and control of the Vitolig circulation pump from the heating water buffer cylinder to the respective consumer.
After the Vitolig has been heated up, it is operated at rated output.
Vitolig boiler circuit pump 3 starts when a boiler water temperature DHW heating by heating water buffer cylinder
of 60 C has been reached. The Vitolig boiler water temperature is below 55 C; the temperature
Either the heating circuit or the DHW cylinder is heated. The heat not of the heating water buffer cylinder at temperature sensor qE lies
drawn off by consumers is transferred to the heating water buffer cyl- 10 K above the set DHW temperature selected at the remote control.
inder. When there is a demand for DHW heating, circulation pump for cylinder
Vitolig boiler circuit pump 3 is switched off by the differential tem- heating 5 starts, and the DHW cylinder is heated by the heating water
perature control unit if the heating water buffer cylinder is heated up buffer cylinder.
and the boiler water temperature is below that at the bottom of the
buffer cylinder (TPU + 5 K) at sensor qR. Heating mode
Below 50 C, Vitolig boiler circuit pump 3 is switched off independent The heat generated by the Vitolig is transferred via circulation pump
of the differential temperature control unit. 3 to the heating circuit and to the heating water buffer cylinder. The
heat not required by the heating circuit is transferred to the heating
5
Return temperature raising facility water buffer cylinder. If the Vitolig boiler water temperature falls, a
The Vitolig requires a minimum return temperature of 45 C. When greater amount of heat is drawn from the heating water buffer cylinder,
boiler circuit pump 3 is switched on, mixing valve 4 opens from the the more mixing valve 4 of the return temperature raising facility
central heating return to the Vitolig in line with the increasing return opens the path from the boiler flow to the return (bypass).
temperature and simultaneously closes from the flow to the return
(bypass).
5822 470 GB

System examples VIESMANN 139


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605021_1001_03

10 10

7 7
6 6
8 8
11 11

WW
31

30

5 4
2 3

37 15
35
1 13

12
14

KW 60 40 50
5

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required
ID: 4605021_1001_03
Pos. Description Quan- Part no.
tity
1 Buffer primary controller PLR2 (standard delivery, Vitolig 200) 1
2 Return temperature raising (26 kW) 1 7373 302
Return temperature raising (40 kW) 1 7373 303
Reducer (only required for the return temperature raising facility 7373 303) 2 7517 579
3 Boiler circuit pump (standard delivery, return temperature raising facility) 1
4 Mixing valve (standard delivery, return temperature raising facility) 1
5 Circulation pump for cylinder heating with check valve 1 7339 467
6 Divicon 1 (2) see pricelist
7 Heating circuit pump (part of the standard delivery of the Divicon) 1 (2)
8 Heating mixer-3 (part of the standard delivery of the Divicon) 1 (2)
9 Manifold for Divicon 1 see pricelist
qP HKR heating circuit controller for regulating a heating circuit with mixer and a DHW cylinder with remote 1 (2) 7159 789
control
Outside temperature sensor 1 7159 817
qQ Mixer motor 1 (2) 7450 657
qW Cylinder temperature sensor 1 7159 822
qE Temperature sensor in the top of the heating water buffer cylinder 1 Standard delivery for
qR Temperature sensor at the bottom of the heating water buffer cylinder 1 the Vitolig 200
qT Sensor well (standard delivery of the heating water buffer cylinder) 2
eP Connection unit, heating water buffer cylinder 1 7159 406
5822 470 GB

eQ Adaptor unit 1 7159 411


eT Low water limiter (low water indicator) 1 9529 050
eZ Thermally activated safety valve 1 7143 845
eU Safety equipment block 1 Z001 849

140 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605021_1001_03
Pos. Description Quan- Part no.
tity
rP Heat source 1 see pricelist
Vitolig 200
tP Heating water buffer cylinder 1 see pricelist
zP DHW cylinder 1 see pricelist

Electrical installation scheme

Connection of circulation pumps, mixer motors and a low water indicator

XW
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1
X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2
BN
BK

auf

auf
N

N
zu

zu
L

L
M M
N
L

XN/N
XN/LI

ID: 4605021_1001_03
5
A Heating circuit 1 D Power supply 230 V/50 Hz
B Heating circuit 2 BK Black
C Buffer primary controller BN Brown

Connection of temperature sensors and remote control units

A B C
13 L-
12 L+
11
10 Gnd

11 Gnd
10

11 Gnd
10
9 Y7
8 Y5
7
6 Gnd
5 Y4
4 Y3
3
2 Gnd
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2

R2
120
5
6

5
6

H G qW F E D qE qR

ID: 4605021_1001_03
5822 470 GB

A Heating circuit 1 E Remote control, heating circuit 2


B Heating circuit 2 F Flow temperature sensor, heating circuit 1
C Buffer primary controller G Outside temperature sensor
D Flow temperature sensor, heating circuit 2 H Remote control, heating circuit 1

System examples VIESMANN 141


Solid fuel boiler (cont.)

Connection of solar components


See the Vitosol technical guide or the Vitosolic 100 installation instruc-
tions.

5822 470 GB

142 VIESMANN System examples


Solid fuel boiler (cont.)

5.8 Vitolig 200 with oil/gas boiler, one or two heating circuits with mixer, heating water
buffer cylinder and DHW heating
When connecting the boiler to a common chimney, thermostats qE
and qZ prevent circulation pump for cylinder heating 5 being
switched ON and the DHW cylinder being cooled down for as long as
the burner is still locked out by flue gas temperature limiter qI and
consequently the oil/gas boiler is still cold. After the Vitolig starts, DHW
is heated up first; central heating is provided thereafter.
3-way mixer 8 of the heating circuit is closed while DHW is heated.
When the DHW temperature set at the cylinder thermostat of the boiler
circuit control unit has been reached, circulation pump 5 is switched
off, 3-way mixer 8 is opened and heat is transferred for central heat-
ID: 4605150_1001_01 ing purposes.

DHW heating by heating water buffer cylinder


Function description The Vitolig boiler water temperature is below 60 C, the temperature
in the heating water buffer cylinder is lower than the value set at ther-
Note mostat qE. 3-way diverter valve qP is open from the Vitolig and the
The temperatures stated in the sample application are standard val- heating water buffer cylinder towards the distributor. Circulation pump
ues; set alternative values according to specific requirements. for cylinder heating 5 runs and the DHW cylinder is heated up. DHW
The heating circuits and a DHW cylinder are heated by the Vitolig, by heating ends, when the temperature set at the cylinder thermostat of
a heating water buffer cylinder and an oil or gas boiler. The operation the boiler circuit control unit has been reached. Circulation pump 5
is automatically changed over between the Vitolig and the oil or gas stops and 3-way diverter valve qP remains open from the Vitolig and
boiler. Both are either connected to different chimneys or to a common the heating water buffer cylinder towards the distributor.
chimney (to DIN 4759-1). Circulation pump 5 will also stop if the actual temperature in the
heating water buffer cylinder falls below that set at thermostat qE. The
Combustion controller and control of the Vitolig circulation pump cylinder is then heated by the oil/gas boiler.
After the Vitolig has been heated up, it is operated at rated output.
Vitolig boiler circuit pump 3 starts when a boiler water temperature Heating mode
of 60 C has been reached.
Either the heating circuit or the DHW cylinder is heated. The heat not Heating by oil or gas boiler
drawn off by consumers is transferred to the heating water buffer cyl- The burner of the oil/gas boiler will be enabled if the Vitolig boiler water
inder. temperature is below 60 C and the temperature in the heating water
Vitolig boiler circuit pump 3 is switched off by the differential tem- buffer cylinder is below the value set at thermostat qW and, when con-
perature control unit if the heating water buffer cylinder is heated up nected to a common chimney, the flue gas temperature is below the
and the boiler water temperature is below that at the bottom of the value set at flue gas thermostat qI, i.e. 60 C. 3-way diverter valve
buffer cylinder (TPU + 5 K) at sensor qT. qP from the oil/gas boiler to the distributor is open.
5
The control unit of the oil or gas boiler automatically adjusts the boiler
Return temperature raising facility water temperature to the respective outside temperature. The heating
The Vitolig requires a minimum return temperature of 45 C. When flow temperature is controlled by the heating circuit control unit via 3-
boiler circuit pump 3 is switched on, mixing valve 4 opens from the way mixer 8 subject to outside temperature.
central heating return towards the Vitolig in line with the increasing
return temperature and simultaneously closes from the boiler flow to Heating by the Vitolig
the boiler return (bypass). 3-way diverter valve qP opens from the Vitolig and the heating water
buffer cylinder towards the distributor if the Vitolig boiler water tem-
DHW heating perature exceeds 60 C and if the DHW cylinder is heated up. The heat
created by the Vitolig is transferred via boiler circuit pump 3 to the
DHW heating by oil or gas boiler heating circuit and to the heating water buffer cylinder. The heat not
The Vitolig boiler water temperature is below 60 C, the temperature required by the heating circuit is transferred to the heating water buffer
in the heating water buffer cylinder is lower than the value set at ther- cylinder.
mostat qE (DHW temperature + 10 K). The heating circuit flow temperature is controlled by the boiler circuit
The burner of the oil or gas boiler starts and circulation pump for cyl- control unit of the oil/gas boiler via 3-way mixer 8.
inder heating 5 runs if the DHW cylinder temperature falls below the
value set at the cylinder thermostat of the boiler circuit control unit. 3- Heating by heating water buffer cylinder
way mixer 8 in the heating circuit is closed and heating circuit pump If the Vitolig boiler water temperature falls, a greater amount of heat is
7 is switched off. 3-way diverter valve qP from the oil/gas boiler to drawn from the heating water buffer cylinder, the more mixing valve
the distributor is open. 4 of the return temperature raising facility opens the path from the
heating flow to the heating return (bypass). If the boiler water temper-
DHW heating by Vitolig ature falls below 55 C, boiler circuit pump 3 stops and heat is only
The Vitolig boiler water temperature is at least 60 C; boiler circuit drawn from the heating water buffer cylinder.
pump 3 runs to raise the return temperature. If the DHW cylinder
temperature falls below the value set at the DHW cylinder thermostat
of the boiler circuit control unit, 3-way diverter valve qP opens towards
the Vitolig and from the heating water buffer cylinder towards the dis-
tributor, circulation pump 5 runs (if the temperature set at thermostat
5822 470 GB

qE is exceeded) and the DHW cylinder is heated up.

System examples VIESMANN 143


Solid fuel boiler (cont.)

The heating water buffer cylinder supplies heat until the actual tem- Note
perature falls below the temperature set at thermostat qW (manually The heating and DHW heating programs must always be controlled by
matched to the heating system return temperature, e.g. 40 C in spring the oil/gas boiler circuit control unit.
and autumn and, for example, 60 C when there is a high heat Recommended settings
demand). Thermostat qW on the heating water buffer cylinder deter- Temperature controller qW: 40 to 60 C
mines the required heating flow temperature. 3-way diverter valve Temperature controller qE: approx. 65 C
qP changes to connect the oil or gas boiler with the distributor, the
burner of the oil or gas boiler starts and heating will be provided by that
same boiler if the temperature inside the heating water buffer cylinder
falls below the value set at thermostat qW.

Hydraulic installation scheme with oil/gas boiler ID: 4605150_1001_01

7 7
6 6
8 8

WW
I
10
II III

30

5 4
2 3

5
37 12
1 35
13
16
14
11 18
17
15

19

KW 60 40 50 A

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

A Oil/gas boilers

Equipment required
ID: 4605150_1001_01
Pos. Description Quan- Part no.
tity
1 Contact thermostat 1 7404 730
2 Return temperature raising (26 kW) 1 7373 302
Return temperature raising (40 kW) 1 7373 303
Reducer (only required for the return temperature raising facility 7373 303) 2 7517 579
3 Boiler circuit pump (standard delivery, return temperature raising facility) 1
4 Mixing valve (standard delivery, return temperature raising facility) 1
5 Circulation pump for cylinder heating with check valve 1 7339 467
5822 470 GB

6 Divicon 1 (2) see pricelist


7 Heating circuit pump (part of the standard delivery of the Divicon) 1 (2)
8 Heating mixer-3 (part of the standard delivery of the Divicon) with 1 (2)
Extension kit for the Vitotronic 1 (2) see pricelist

144 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605150_1001_01
Pos. Description Quan- Part no.
tity
9 Manifold for Divicon 1 see pricelist
qP Diverter valve connection unit

R1 1 7159 407
R1 1 7159 408
qQ Cylinder temperature sensor 1 Standard delivery,
control unit
qW Temperature controller 1 7151 989
qE Temperature controller 1 7151 989
qR Temperature sensor in the top of the heating water buffer cylinder 1 Standard delivery
qT Temperature sensor at the bottom of the heating water buffer cylinder 1 for the Vitolig 200
qZ Control thermostat (install the sensor into the boiler sensor well) 1 7151 989
qU Wiring chamber 1 7408 901
and (subject to the oil/gas boiler)
External extension H5 for the Vitotronic 200, KW1 to KW5 1 7199 249
Plug-in adaptor for oil/gas boilers without Vitotronic control unit 1 7402 100
eP Connection unit, heating water buffer cylinder 1 7159 406
eT Low water limiter (low water indicator) 1 9529 050
eZ Thermally activated safety valve 1 7143 845
eU Safety equipment block 1 Z001 849
rP Heat source 1 see pricelist
Vitolig 200
tP Heating water buffer cylinder 1 see pricelist
zP DHW cylinder 1 see pricelist
When connecting the boilers to a common chimney
qI Flue gas temperature limiter to lock out the burner 1 7143 844
qO Door interlock switch (fit to the ash door) 1 7159 777

Electrical installation scheme

Connection for boiler circuit pumps and a low water indicator on the Vitolig 200 control unit

XW A B C
5
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1
X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2
BN
BK

3
eT

XN/N
D
XN/LI

ID: 4605150_1001_01

A Heating circuit 1 D Power supply 230 V/50 Hz


B Heating circuit 2 BK Black
C Buffer primary controller BN Brown
5822 470 GB

System examples VIESMANN 145


Solid fuel boiler (cont.)

Heating water buffer cylinder temperature sensor connection at the Vitolig 200 control unit

A B C
13 L-
12 L+
11
10 Gnd

11 Gnd
10

11 Gnd
10
9 Y7
8 Y5
7
6 Gnd
5 Y4
4 Y3
3
2 Gnd
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2
R2
120

qR qT

ID: 4605150_1001_01

A Heating circuit 1
B Heating circuit 2
C Buffer primary controller

5822 470 GB

146 VIESMANN System examples


5822 470 GB
1,2
4 13 7 9 23 21 71 43 43
S1 K1 K1 K3 K1 K3 K4
1 14 qW qE 24 22 72 44 44
2 11 S2
5 8 10
20 71 33 43
1,2 13 13 22 K3 K1 K2
K4 A1 K2 31 53 72 34 44
14 K4 14 K2 K3 31

System examples
21 54
qZ
S2 51
61 A2 32 K3
K1 K1 23 32

ID: 4605150_1001_01
52 1,2 62
S3
21 13 S3 19
L 1 K2 K3 6 12 BR Y1 13 14
22 14 CLOSED 5
3 SW Y2
A1 M A1 A1 qP M
OPEN
Solid fuel boiler (cont.)

H1 K1 H2 K2 K3 H3
N N 15 16 17 18 3 N N N 24 25
Wiring diagram of junction box qU

A2 A2 A2
L

L 1 2 3 4 5 6 7 8 9 10 11 12 1314 15 16 17 18 19 20 21 22 23 24 25
N N N N N
3 3 2 2 3
C T2 S3 150
1 M 1 1 L N 21 Y1Y2 N 1 M H 1
1~ 1~
A B D2 6

E TRTR 150 1 3 qW qE F qP qO qI 5 qZ

or
G

L1 N T1 T2 S3 B4 41

L1
4 3 N
L1 N T1 T2 S3 B4 41

VIESMANN
147
5
Solid fuel boiler (cont.)

A Power supply 230 V/50 Hz qP 3-way diverter valve (connection unit)


Fit a main isolator in accordance with local regulations. Line fuse qW Control thermostat in the heating water buffer cylinder
max. 16 A qE Control thermostat in the heating water buffer cylinder
B Power supply 230 V/50 Hz for the boiler circuit control unit qZ Control thermostat in the oil/gas boiler or the wall mounted boiler
C Terminals at plug 150 Dekamatik qI Flue gas temperature limiter
D Terminals at terminal strip X6 Viessmann Trimatik qO Door interlock switch
E Terminals at plug 150 Vitotronic 200, KW1 and KW2 to 4/2004 S1 Vitolig ON - OFF
and Vitotronic 300, KW3 S2 Oil/gas boiler OFF - Automatic
or S3 Emissions test switch
Terminals at plug 150 at the external extension H5, part no. H1 Mode
7199 249, for Vitotronic 200, KW1 to KW5 H2 Vitolig operation
or H3 Circulation pump for cylinder heating operation
Plug-in adaptor, part no. 7402 100, for the connection of oil/gas
boilers without a Vitotronic control unit Function changes at the Vitotronic 200 or 300:
F Plug 21 Vitotronic Function Code
(Circulation pump for cylinder heating connection) Circulation pump for cylinder heating activated irre- 61: 1
G Remove jumpers when connecting the boilers to a common chim- spective of boiler water temperature
ney Circulation pump for cylinder heating immediately 62: 0
L Jumper fitted in the delivered condition deactivated, without run-on
1 Contact thermostat
3 Connection of boiler circuit pump 3 Note
Terminals LV 230 V/50 Hz X2/N/PE (see page 145) Control thermostat: The illustration shows the cold state.
5 Circulation pump for cylinder heating

Connection of solar components


See the Vitosol technical guide or the Vitosolic 100 installation instruc-
tions.

5822 470 GB

148 VIESMANN System examples


Solid fuel boiler (cont.)

5.9 Vitolig 200 with wall mounted oil/gas boiler and one or two heating circuits with mixer,
heating water buffer cylinder and DHW cylinder
When connecting the boiler to a common chimney, thermostats qE
and qZ prevent circulation pump for cylinder heating 5 being
switched ON and the DHW cylinder being cooled down for as long as
the burner is still locked out by flue gas temperature limiter qI and
consequently the wall mounted oil/gas boiler is still cold. After the
Vitolig starts, DHW is heated up first; central heating is provided there-
after.
3-way mixer 8 of the heating circuit is closed while DHW is heated.
When the DHW temperature set at the cylinder thermostat of the boiler
circuit control unit has been reached, circulation pump 5 is switched
ID: 4605151_1001_01 off, 3-way mixer 8 is opened and heat is transferred for central heat-
ing purposes.

Function description DHW heating by heating water buffer cylinder


The Vitolig boiler water temperature is below 60 C, the temperature
Note in the heating water buffer cylinder is lower than the value set at ther-
The temperatures stated in the sample application are standard val- mostat qE. 3-way diverter valve qP is open from the Vitolig and the
ues; set alternative values according to specific requirements. heating water buffer cylinder towards the distributor. Circulation pump
The heating circuits and a DHW cylinder are heated by the Vitolig, by for cylinder heating 5 runs and the DHW cylinder is heated up. DHW
a heating water buffer cylinder and a wall mounted oil/gas boiler. The heating ends, when the temperature set at the cylinder thermostat of
operation is automatically changed over between the Vitolig and the the boiler circuit control unit has been reached. Circulation pump 5
wall mounted oil/gas boiler. Both are connected to separate chim- stops and 3-way diverter valve qP remains open from the Vitolig and
neys. the heating water buffer cylinder towards the distributor.
Circulation pump 5 will also stop if the actual temperature in the
Combustion controller and control of the Vitolig circulation pump heating water buffer cylinder falls below that set at thermostat qE. The
After the Vitolig has been heated up, it is operated at rated output. cylinder is then heated by the wall mounted oil/gas boiler.
Vitolig boiler circuit pump 3 starts when a boiler water temperature
of 60 C has been reached. Heating mode
Either the heating circuit or the DHW cylinder is heated. The heat not
drawn off by consumers is transferred to the heating water buffer cyl- Heating by wall mounted oil/gas boiler
inder. The burner of the wall mounted oil/gas boiler will be enabled if the
Vitolig boiler circuit pump 3 is switched off by the differential tem- Vitolig boiler water temperature is below 60 C and the temperature in
perature control unit if the heating water buffer cylinder is heated up the heating water buffer cylinder is below the value set at thermostat
and the boiler water temperature is below that at the bottom of the qW and, when connected to a common chimney, the flue gas temper-
buffer cylinder (TPU + 5 K) at sensor qT. ature is below the value set at flue gas thermostat qI, i.e. 60 C. 3-
5
way diverter valve qP from the oil/gas boiler to the distributor is
Return temperature raising facility open.
The Vitolig requires a minimum return temperature of 45 C. When The control unit of the wall mounted oil/gas boiler automatically adjusts
boiler circuit pump 3 is switched on, mixing valve 4 opens from the the boiler water temperature to the respective outside temperature.
central heating return towards the Vitolig in line with the increasing The heating flow temperature is controlled by the heating circuit control
return temperature and simultaneously closes from the boiler flow to unit via 3-way mixer 8 subject to outside temperature.
the boiler return (bypass).
Heating by the Vitolig
DHW heating 3-way diverter valve qP opens from the Vitolig and the heating water
buffer cylinder towards the distributor if the Vitolig boiler water tem-
DHW heating by the wall mounted oil/gas boiler perature exceeds 60 C and if the DHW cylinder is heated up. The heat
The Vitolig boiler water temperature is below 60 C, the temperature created by the Vitolig is transferred via boiler circuit pump 3 to the
in the heating water buffer cylinder is lower than the value set at ther- heating circuit and to the heating water buffer cylinder. The heat not
mostat qE (DHW temperature + 10 K). required by the heating circuit is transferred to the heating water buffer
The burner of the wall mounted oil/gas boiler starts and circulation cylinder.
pump for cylinder heating 5 runs if the DHW cylinder temperature The heating circuit flow temperature is controlled by the boiler circuit
falls below the value set at the cylinder thermostat of the boiler circuit control unit of the wall mounted oil/gas boiler via 3-way mixer 8.
control unit. 3-way mixer 8 in the heating circuit is closed and heating
circuit pump 7 is switched off. 3-way diverter valve qP from the wall Heating by heating water buffer cylinder
mounted oil/gas boiler to the distributor is open. If the Vitolig boiler water temperature falls, a greater amount of heat is
drawn from the heating water buffer cylinder, the more mixing valve
DHW heating by Vitolig 4 of the return temperature raising facility opens the path from the
The Vitolig boiler water temperature is at least 60 C; boiler circuit heating flow to the heating return (bypass). If the boiler water temper-
pump 3 runs to raise the return temperature. If the DHW cylinder ature falls below 55 C, boiler circuit pump 3 stops and heat is only
temperature falls below the value set at the DHW cylinder thermostat drawn from the heating water buffer cylinder.
of the boiler circuit control unit, 3-way diverter valve qP opens towards
the Vitolig and from the heating water buffer cylinder towards the dis-
tributor, circulation pump 5 runs (if the temperature set at thermostat
5822 470 GB

qE is exceeded) and the DHW cylinder is heated up.

System examples VIESMANN 149


Solid fuel boiler (cont.)

The heating water buffer cylinder supplies heat until the actual tem- Note
perature falls below the temperature set at thermostat qW (manually The heating and DHW heating functions must always be controlled by
matched to the heating system return temperature, e.g. 40 C in spring the control unit of the wall mounted oil/gas boiler.
and autumn and, for example, 60 C when there is a high heat Recommended settings
demand). Thermostat qW on the heating water buffer cylinder deter- Temperature controller qW: 40 to 60 C
mines the required heating flow temperature. If the temperature inside Temperature controller qE: approx. 65 C
the heating water buffer cylinder falls below the value set at thermostat
qW, 3-way diverter valve qP changes to connect the wall mounted oil/
gas boiler with the distributor, the burner of the wall mounted oil/gas
boiler starts and heating will be provided by that boiler.

Hydraulic installation scheme ID: 4605151_1001_01

7 7
6 6
8 8

9 21

WW
I 16
10 III
II

30 20

5 4
2 3

5 22
37 12
1 35
13
14
11 18
17
15
70

KW 60 40 50

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required
ID: 4605151_1001_01
Pos. Description Quan- Part no.
tity
1 Contact thermostat 1 7404 730
2 Return temperature raising (26 kW) 1 7373 302
Return temperature raising (40 kW) 1 7373 303
Reducer (only required for the return temperature raising facility 7373 303) 2 7517 579
3 Boiler circuit pump (standard delivery, return temperature raising facility) 1
4 Mixing valve (standard delivery, return temperature raising facility) 1
5 Circulation pump for cylinder heating with check valve 1 7339 467
6 Divicon 1 (2) see pricelist
7 Heating circuit pump (part of the standard delivery of the Divicon) 1 (2)
5822 470 GB

8 Heating mixer-3 (part of the standard delivery of the Divicon) with 1 (2)
Extension kit for one heating circuit with mixer (part of the standard delivery of the Divicon)
9 Manifold for Divicon 1 see pricelist
qP Diverter valve connection unit

150 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605151_1001_01
Pos. Description Quan- Part no.
tity
R1 1 7159 407
R1 1 7159 408
qQ Cylinder temperature sensor 1 7179 114
qW Temperature controller 1 7151 989
qE Temperature controller 1 7151 989
qR Temperature sensor in the top of the heating water buffer cylinder 1 Standard delivery
qT Temperature sensor at the bottom of the heating water buffer cylinder 1 for the Vitolig 200
qZ Control thermostat (sensor in/at the low loss header) 1 7151 989
qU Wiring chamber 1 7408 901
wP Low loss header 1 see pricelist
wQ Flow temperature sensor inside the low loss header 1 7179 488
wW Wall mounted oil/gas boiler circuit control unit 1 part of the stand-
ard delivery of the
wall mounted
boiler
System without DHW circulation:
wE Internal extension H1 1 7179 057
or
wR Internal extension H2 1 7179 144
System with DHW circulation additionally:
wT Extension AM1 1 7429 152
wZ Extension EA1 1 7429 151
eP Connection unit, heating water buffer cylinder 1 7159 406
eT Low water limiter (low water indicator) 1 9529 050
eZ Thermally activated safety valve 1 7143 845
eU Safety equipment block 1 Z001 849
rP Heat source 1 see pricelist
Vitolig 200
tP Heating water buffer cylinder 1 see pricelist
zP DHW cylinder 1 see pricelist
uP Vitopend 200-W, Vitodens 200-W/300-W, Vitoladens 300-W 1 see pricelist

Electrical installation scheme

Connection for boiler circuit pumps and a low water indicator on the Vitolig 200 control unit 5

XW A B C
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1
X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2
BN
BK

3
eT

XN/N
D
XN/LI

ID: 4605151_1001_01

A Heating circuit 1 D Power supply 230 V/50 Hz


5822 470 GB

B Heating circuit 2 BK Black


C Buffer primary controller BN Brown

System examples VIESMANN 151


Solid fuel boiler (cont.)

Heating water buffer cylinder temperature sensor connection at the Vitolig 200 control unit

A B C
13 L-
12 L+
11
10 Gnd

11 Gnd
10

11 Gnd
10
9 Y7
8 Y5
7
6 Gnd
5 Y4
4 Y3
3
2 Gnd
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2
R2
120

qR qT

ID: 4605151_1001_01

A Heating circuit 1
B Heating circuit 2
C Buffer primary controller

5822 470 GB

152 VIESMANN System examples


Solid fuel boiler (cont.)

Electrical installation diagram, wall mounted oil/gas boilers

23
22
22 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
53 L
L
96 96 23 24 1
N 12
N
28 17
40 26 L 11

24
LON
22 L
96
5 96 N

X3.7 P
X3.6 157
S
X3.5
X3.4 12
Low voltage

N
X3.3 28 17
L 11

X3.2
X3.1 26

22 N
40
96 L
N
40A 40 25
L
P
157

S

4
0-10V
3
2 24
DE1 17
1 25
2
1
145
2
1
5

25
26
N
40A 40
L
N
40A
L
N 12
A1 17
L 11
N
A2
L

2 2
145
1 1

ID: 4605151_1001_01

Adjustments required at the Vitopend or Vitodens Change code "3A" to "3A:3",


External blocking of the burner and pump: change code "3E" to "3E:1".
5822 470 GB

System examples VIESMANN 153


5
1,2

154
4 13 7 9 23 21 71 43 43
S1 K1 K1 K3 K1 K3 K4
1 14 qW qE 24 22 72 44 44
2 11 S2
5 8 10
20 71 33 43
1,2 13 13 22 K3 K1 K2
K4 A1 K2 31
53 72 34 44
14 K4 14 K2 K3 qZ 31
S2 51 21 61 A2 32 54 K3
K1 K1 23 32

ID: 4605151_1001_01

VIESMANN
52 1,2 62
S3
21 13 S3 19
L 1 K2 K3 6 12 BR Y1 13 14
22 14 ZU 5
3 SW Y2
A1 M A1 A1 qP M
Solid fuel boiler (cont.)

H1 K1 H2 K2 K3 AUF
H3
N N 15 16 17 18 3 N N N 24 25
Wiring diagram of junction box qU

A2 A2 A2
L

L 1 2 3 4 5 6 7 8 9 10 11 12 1314 15 16 17 18 19 20 21 22 23 24 25
N N N N N
3 3 2 2 3
1 M 1 1 L N 21 Y1Y2 N 1 M H 1
1~
KDE1.1DE1.2
A B 1~

1 3 qW qE F qP qO qI 5 qZ
G

System examples
5822 470 GB
Solid fuel boiler (cont.)

A Power supply 230 V/50 Hz qW Control thermostat in the heating water buffer cylinder
Fit a main isolator in accordance with local regulations. Line fuse qE Control thermostat in the heating water buffer cylinder
max. 16 A qZ Control thermostat in the wall mounted oil/gas boiler or wall moun-
B Power supply 230 V/50 Hz for the boiler circuit control unit ted boiler
F Plug 21 at the internal extension H1 or H2 or at extension AM1 S1 Vitolig ON - OFF
(Circulation pump for cylinder heating connection) S2 Oil/gas boiler OFF - Automatic
K Terminals at plug DE1 of extension EA1 of the Vitodens 200-W/ S3 Emissions test switch
300-W, Vitopend 200-W or Vitoplus 300/Vitoladens 300-W H1 Mode
L Jumper fitted in the delivered condition H2 Vitolig operation
1 Contact thermostat H3 Circulation pump for cylinder heating operation
3 Connection of boiler circuit pump 3
Terminals LV 230 V/50 Hz X2/N/PE (see page 151) Note
5 Circulation pump for cylinder heating Control thermostat: The illustration shows the cold state.
qP 3-way diverter valve (connection unit)

Connection of solar components


See the Vitosol technical guide or the installation instructions of the
solar control module (type SM1).

5
5822 470 GB

System examples VIESMANN 155


Solid fuel boiler (cont.)

5.10 Vitolig 200 with oil/gas boiler, one or two heating circuits with mixer, heating water
buffer cylinder and multi-mode heating water buffer cylinder with DHW heating
The entire top section of the Vitocell 340-M/360-M is heated, thereby
also heating DHW.

Central heating by boiler and solar energy


3-way diverter valve 9 is switched to position "AB-A" if a temperature
differential higher than differential temperature 2 set in Vitosolic 200
wP is captured between temperature sensor wT and heating circuit
return temperature sensor wZ. The heating return water is fed to boiler
uP via combi cylinder zP. If the temperature of the preheated return
water is too low, boiler uP reheats the water to the required flow tem-
ID: 4605152_1001_01 perature.

DHW heating without solar energy


Function description The top section of combi cylinder zP is heated by boiler uP. The inte-
gral instantaneous water heater/standby section is heated by the sur-
Note rounding buffer cylinder water. The cylinder thermostat with connected
The temperatures stated in the sample application are standard val- cylinder temperature sensor qP of boiler circuit control unit uP
ues; set alternative values according to specific requirements. switches circulation pump for cylinder heating 4.
The heating circuits and one DHW cylinder are heated by the Vitolig,
a Vitocell 340-M/360-M, a heating water buffer cylinder and an oil/gas DHW heating with solar energy
boiler. The operation is automatically changed over between the Vitolig Solar circuit pump wR starts and combi cylinder zP will be heated if a
and the oil or gas boiler. Both are either connected to separate chim- temperature differential greater than differential temperature 1 set in
neys or to a common chimney to DIN 4759-1. Vitosolic 200 wP is captured between collector temperature sensor
wQ and cylinder temperature sensor wW. For this, the temperature
Combustion controller and control of the Vitolig circulation pump inside the combi cylinder will be limited by electronic temperature lim-
After the Vitolig has been heated up, it is operated at rated output. iter wP in the Vitosolic 200.
Vitolig boiler circuit pump 2 starts when a boiler water temperature This switches solar circuit pump wR off when the actual temperature
of 60 C has been reached. Either the heating circuit or the DHW cyl- falls below the set temperature. The electronic temperature limiter is
inder is heated. The heat not drawn off by consumers is transferred to preset at the factory to 60 C and can be adjusted. The entire combi
the heating water buffer cylinder. cylinder will be heated by the solar thermal system if the insolation is
If the Vitocell 340-M/360-M or the heating water buffer cylinder is adequate for heating the DHW. The top section of the combi cylinder
heated up and the boiler water temperature is below that at the bottom will only be reheated by the boiler if the temperature set at the boiler
of the buffer cylinder TPU + 5 K) at sensor qW, Vitolig boiler circuit pump circuit control unit is no longer achieved. The DHW in the lower area
2 is switched off by the differential temperature control unit. of the Vitocell 340-M/360-M will be preheated by solar energy and the
5 top section is heated to the required temperature by the boiler if the
Return temperature raising facility insolation is too low.
The Vitolig requires a minimum return temperature of 45 C. When
boiler circuit pump 2 is switched on, mixing valve 3 opens from the Safety instructions
central heating return towards the Vitolig in line with the increasing When temperatures exceed 60 C, limit the DHW temperature to
return temperature and simultaneously closes from the boiler flow to 60 C by installing a mixing device, e.g. a thermostatic mixing valve
the boiler return (bypass). (accessory for DHW cylinders). The mixing device does not prevent
the risk of scalding at the draw-off point. The installation of a mixer tap
Heating by the Vitolig at the draw-off point is essential.
The heat generated by the Vitolig is transferred by boiler circuit pump
2 to the Vitocell 340-M/360-M or to the heating water buffer cylinder
if the Vitolig boiler water temperature exceeds 60 C.
5822 470 GB

156 VIESMANN System examples


Solid fuel boiler (cont.)

Hydraulic installation scheme with oil/gas boiler ID: 4605152_1001_01

20 6 6
5 5
7 7

26

AB
B
9 A

WW

4
3

1 2

HV1
WW/Z 38
10 14
37 11
HV2/HR1
25 35
HR2
37 12
15 13
22 HR3
KW
E
HVs/HRs 12

60 50 40 70 5
KW

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required
ID: 4605152_1001_03
Pos. Description Quan- Part no.
tity
1 Return temperature raising (26 kW) 1 7373 302
Return temperature raising (40 kW) 1 7373 303
Reducer (only required for the return temperature raising facility 7373 303) 2 7517 579
2 Boiler circuit pump (standard delivery, return temperature raising facility) 1
3 Mixing valve (standard delivery, return temperature raising facility) 1
4 Circulation pump for cylinder heating with check valve 1 7339 467
5 Divicon 1 (2) see pricelist
6 Heating circuit pump (part of the standard delivery of the Divicon) 1 (2)
7 Heating mixer-3 (part of the standard delivery of the Divicon) with 1 (2)
Extension kit for one heating circuit with mixer (part of the standard delivery of the Divicon)
8 Manifold for Divicon 1 see pricelist
9 3-way diverter valve (R 1 for the Vitolig up to 26 kW) 1 7814 924
qP Cylinder temperature sensor for the Vitotronic 200 or 300 1 Standard delivery,
control unit
qQ Temperature sensor at the top of the Vitocell 340-M/360-M 1 Standard delivery for
qW Temperature sensor at the bottom of the heating water buffer cylinder 1 the Vitolig 200
eT Low water limiter (low water indicator) 1 9529 050
eZ Thermally activated safety valve 1 7143 845
eU Threaded elbow 2 7219 729
5822 470 GB

eI Safety equipment block 1 Z001 849


rP Vitolig 200 1 see pricelist
tP Heating water buffer cylinder 1 see pricelist

System examples VIESMANN 157


Solid fuel boiler (cont.)

ID: 4605152_1001_03
Pos. Description Quan- Part no.
tity
zP Vitocell 340-M/360-M 1 see pricelist
uP Oil/gas boilers 1 see pricelist
When connecting the boilers to a common chimney
qE Control thermostat (install the probe into the sensor well of the oil or gas boiler) 1 7151 989
qR Flue gas temperature limiter to lock out the burner 1 7143 844
qT Door interlock switch (fit to the ash door) 1 7159 777

Required control equipment for the solar circuit


ID: 4605152_1001_01
Pos. Description Quan- Part no.
tity
Control of combi cylinder heating by solar energy
wP Vitosolic 200, type SD4 1 Z007 388
wQ Collector temperature sensor 1 Standard delivery for
pos. wP
wW Cylinder temperature sensor 1 Standard delivery for
pos. wP
wE Solar-Divicon 1 see pos. wR
wR Solar circuit pump 1 Standard delivery for
pos. wE
Central heating control with solar energy
wT Temperature sensor (combi cylinder) 1 Standard delivery for
pos. wP
wZ Return temperature sensor (heating circuit) 1 7426 247

Electrical installation scheme

Connection for boiler circuit pumps and a low water indicator on the Vitolig 200 control unit

XW A B C
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1
X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2

5
BN
BK

2
eT

XN/N
D
XN/LI

ID: 4605152_1001_01

A Heating circuit 1 D Power supply 230 V/50 Hz


B Heating circuit 2 BK Black
C Buffer primary controller BN Brown
5822 470 GB

158 VIESMANN System examples


Solid fuel boiler (cont.)

Heating water buffer cylinder temperature sensor connection at the Vitolig 200 control unit

A B C
13 L-
12 L+
11
10 Gnd

11 Gnd
10

11 Gnd
10
9 Y7
8 Y5
7
6 Gnd
5 Y4
4 Y3
3
2 Gnd
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2
R2
120

qQ qW

ID: 4605152_1001_01

A Heating circuit 1
B Heating circuit 2
C Buffer primary controller

Only if the oil/gas boiler and the Vitolig are connected to a common chimney

Connection of the circulation pump for cylinder heating


Function: 21
Thermostat qE prevents the starting of circulation pump for cylinder
L N
heating 4 when the oil/gas boiler is still blocked by the flue gas ther-
mostat and there is an active cylinder demand.

1 M
2 3 1~

ID: 4605023_1001_03

A Plug-in connector sA of the Vitotronic


B Thermostat qE in the oil/gas boiler
C Circulation pump for cylinder heating 4

Locking out the oil/gas boiler by the flue gas temperature limiter
and the door interlock switch on the Vitolig 200
Function:
The burner of the oil/gas boiler is switched off if the flue gas tempera-
ture exceeds 60 C or if the door is opened.
5822 470 GB

System examples VIESMANN 159


Solid fuel boiler (cont.)

C Door contact switch


150 D Flue gas temperature limiter

STB TR EIN
N STB TR EIN A

D C

ID: 4605152_1001_01

A Plug-in connector aB in the Vitotronic


or at the external extension H5
B Remove the jumper when making this connection

Connection of solar components


See the Vitosol technical guide or the Vitosolic 200 installation instruc-
tions.

5822 470 GB

160 VIESMANN System examples


Solid fuel boiler (cont.)

5.11 Vitolig 200 with wall mounted oil/gas boiler, one or two heating circuits with mixer,
heating water buffer cylinder and multi-mode heating water buffer cylinder with DHW
heating
The entire top section of the Vitocell 340-M/360-M is heated, thereby
also heating DHW.

Central heating by wall mounted boiler and solar energy


3-way diverter valve 9 is switched to position "AB-A" if a temperature
differential greater than differential temperature 2 set on the solar con-
trol module (type SM1) wP is captured between temperature sensor
wT and heating circuit return temperature sensor wZ. The heating
return water is routed via combi cylinder zP into wall mounted boiler
uP (via low loss header qZ). If the temperature of the preheated return
ID: 4605153_1001_01 water is too low, wall mounted boiler uP reheats it to the required flow
temperature.

Function description DHW heating without solar energy


The top section of combi cylinder zP is heated by wall mounted boiler
Note uP. The integral instantaneous water heater/standby section is heated
The temperatures stated in the sample application are standard val- by the surrounding buffer cylinder water. The cylinder thermostat with
ues; set alternative values according to specific requirements. connected cylinder temperature sensor qP of wall mounted boiler cir-
The heating circuits and one DHW cylinder are heated by the Vitolig, cuit control unit uP switches circulation pump for cylinder heating
a Vitocell 340-M/360-M, a heating water buffer cylinder and a wall 4.
mounted oil/gas boiler. The operation is automatically changed over
between the Vitolig and the wall mounted oil/gas boiler. Both are either DHW heating with solar energy
connected to separate chimneys or to a common chimney to DIN Solar circuit pump wR starts and the combi cylinder will be heated if a
4759-1. temperature differential greater than differential temperature 1 set in
solar control module (type SM1) wP is captured between collector
Combustion controller and control of the Vitolig circulation pump temperature sensor wQ and cylinder temperature sensor wW. For this,
After the Vitolig has been heated up, it is operated at rated output. the temperature inside the combi cylinder will be limited by electronic
Vitolig boiler circuit pump 2 starts when a boiler water temperature temperature limiter in the solar control module (type SM1) wP.
of 60 C has been reached. Either the heating circuit or the DHW cyl- This switches solar circuit pump wR off when the actual temperature
inder is heated. The heat not drawn off by consumers is transferred to falls below the set temperature. The electronic temperature limiter is
the heating water buffer cylinder. preset at the factory to 60 C and can be adjusted. The entire combi
If the Vitocell 340-M/360-M or the heating water buffer cylinder is cylinder will be heated by the solar thermal system if the insolation is
heated up and the boiler water temperature is below that at the bottom adequate for heating the DHW. The top section of the combi cylinder 5
of the buffer cylinder TPU + 5 K) at sensor qW, Vitolig boiler circuit pump will only be reheated by the boiler if the temperature set at the boiler
2 is switched off by the differential temperature control unit. circuit control unit is no longer achieved. The DHW in the lower area
of the Vitocell 340-M/360-M will be preheated by solar energy and the
Return temperature raising facility top section is heated to the required temperature by the boiler if the
The Vitolig requires a minimum return temperature of 45 C. When insolation is too low.
boiler circuit pump 2 is switched on, mixing valve 3 opens from the
central heating return towards the Vitolig in line with the increasing Safety instructions
return temperature and simultaneously closes from the boiler flow to When temperatures exceed 60 C, limit the DHW temperature to
the boiler return (bypass). 60 C by installing a mixing device, e.g. a thermostatic mixing valve
(accessory for DHW cylinders). The mixing device does not prevent
Heating by the Vitolig the risk of scalding at the draw-off point. The installation of a mixer tap
The heat generated by the Vitolig is transferred by boiler circuit pump at the draw-off point is essential.
2 to the Vitocell 340-M/360-M or to the heating water buffer cylinder
if the Vitolig boiler water temperature exceeds 60 C.
5822 470 GB

System examples VIESMANN 161


Solid fuel boiler (cont.)

Hydraulic installation scheme with ID: 4605153_1001_01

20 6 6
5 5
7 7

26

AB
B
9 A

WW
17
27

4
3

1 2

16
HV1
WW/Z 18
38
10 14
37 11
HV2/HR1
25 35
HR2
37 12
15
22 HR3
KW
70
E
HVs/HRs 12

5 60 50 40

KW

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required
ID: 4605153_1001_01
Pos. Description Quan- Part no.
tity
1 Return temperature raising (26 kW) 1 7373 302
Return temperature raising (40 kW) 1 7373 303
Reducer (only required for the return temperature raising facility 7373 303) 2 7517 579
2 Boiler circuit pump (standard delivery, return temperature raising facility) 1
3 Mixing valve (standard delivery, return temperature raising facility) 1
4 Circulation pump for cylinder heating with check valve UPSB 1 7339 467
5 Divicon 1 (2) see pricelist
6 Heating circuit pump (part of the standard delivery of the Divicon) 1 (2)
7 Heating mixer-3 (part of the standard delivery of the Divicon) with 1 (2)
Extension kit for one heating circuit with mixer (part of the standard delivery of the Divicon)
8 Manifold for Divicon 1 see pricelist
9 3-way diverter valve (R 1 for the Vitolig up to 26 kW) 1 7814 924
qP Cylinder temperature sensor of the wall mounted boiler 1 part of the stand-
ard delivery of the
cylinder connec-
tion set
qQ Temperature sensor at the top of the Vitocell 340-M/360-M 1 Standard delivery
qW Temperature sensor at the bottom of the heating water buffer cylinder 1 for the Vitolig 200
qZ Low loss header 1 see pricelist
5822 470 GB

qU Flow temperature sensor 1 7179 488

162 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605153_1001_01
Pos. Description Quan- Part no.
tity
qI Wall mounted oil/gas boiler circuit control unit 1 part of the stand-
ard delivery of the
wall mounted
boiler
wU DHW circulation pump ZP 1 on-site
System without DHW circulation:
(Internal extension H1 or H2 for switching the circulation pump for cylinder heating)
wO Internal extension H1 1 7179 057
or
eP Internal extension H2 1 7179 144
System with DHW circulation or with the Vitoladens 300-W:
eQ Extension AM1 1 7429 152
eT Low water limiter (low water indicator) 1 9529 050
eZ Thermally activated safety valve 1 7143 845
eU Threaded elbow 2 7219 729
eI Safety equipment block 1 Z001 849
rP Vitolig 200 1 see pricelist
tP Heating water buffer cylinder 1 see pricelist
zP Vitocell 340-M/360-M 1 see pricelist
uP Vitopend 200-W, Vitodens 200-W/300-W, Vitoladens 300-W 1 see pricelist

Required control equipment for the solar circuit


ID: 4605153_1001_01
Pos. Description Quan- Part no.
tity
Control of combi cylinder heating by solar energy
wP Solar control module, type SM1 1 7429 073
wQ Collector temperature sensor 1 Standard delivery
for pos. wP
wW Cylinder temperature sensor 1 Standard delivery
for pos. wP
wE Solar-Divicon 1 see pos. wR
wR Solar circuit pump 1 Standard delivery
for pos. wE
Central heating control with solar energy 5
wT Temperature sensor (combi cylinder) 1 7438 702
wZ Return temperature sensor (heating circuit) 1 7438 702
5822 470 GB

System examples VIESMANN 163


Solid fuel boiler (cont.)

Electrical installation scheme

Connection for boiler circuit pumps and a low water indicator on the Vitolig 200 control unit

XW A B C
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1

8
7
6
5
4
3
2
1
X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2

X9
N
X6
X4
N
X2
BN
BK

L
2
eT

XN/N
D
XN/LI

ID: 4605153_1001_01

A Heating circuit 1 D Power supply 230 V/50 Hz


B Heating circuit 2 BK Black
C Buffer primary controller BN Brown

Heating water buffer cylinder temperature sensor connection at the Vitolig 200 control unit

5
A B C
13 L-
12 L+
11
10 Gnd

11 Gnd
10

11 Gnd
10
9 Y7
8 Y5
7
6 Gnd
5 Y4
4 Y3
3
2 Gnd
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2

9 Y7
8 Y5
7 Gnd
6
5 Y4
4 Y3
3 Gnd
2
1 Y2

R2
120

qQ qW

ID: 4605153_1001_01

A Heating circuit 1
B Heating circuit 2
C Buffer primary controller

Connection of the on-site circulation pump for cylinder heating


to the internal extension H1
with the Vitopend 200-W, Vitodens 200-W/300-W up to 35 kW, Vito-
ladens 300-W
5822 470 GB

164 VIESMANN System examples


Solid fuel boiler (cont.)

Required changes on the wall mounted boiler


Function of output sK of the internal extension:
Change code "53" to "53:3",
with internal extension H1 or H2: Change code "53" to "53:3".
1L N M with extension AM1: Change code "33" to "33:2".
1~

L N N 1L N L
96 53 28

ID: 4605153_1001_01

sK Circulation pump for cylinder heating


gD External safety valve (LPG)
lH Power supply

Electrical installation diagram, wall mounted boilers

29
18
18 L
N
96
40 230 V / 50 Hz 96 N
L
230 V / 50 Hz

N
53 L
L
96 96 29 30 1
N
N
28 M
1~ UPSB 4
40 31 L

30 5
LON
18 L
96
5 96 N

X3.7 P
X3.6 157
S
X3.5
X3.4
Low voltage

N
28 M
X3.3 1~ UPSB 4
L

X3.2
X3.1
31
18
N
96 40
L
N
40A
L
N
A1 M
1~ UPSB 4
L
N
A2 M
1~ ZP 27
L

2 2
145
1 1

ID: 4605153_1001_01
5822 470 GB

Connection of solar components


See the Vitosol technical guide or the installation instructions of the
solar control module (type SM1).

System examples VIESMANN 165


Solid fuel boiler (cont.)

5.12 Vitoligno 300-P with one or two heating circuits with mixer, DHW cylinder (optional
with dual mode DHW cylinder and solar thermal system)
If the heating circuits are regulated via Vitotronic 200 (type FO1) 2,
heating circuit pumps M1 eE and M2 rE stop, and mixers M1 eR and
M2 rR are closed, subject to absolute priority being enabled.
With modulating priority (recommended), heating circuit pumps M1
eE and M2 rE remain switched on, and mixers M1 eR and M2 rR are
closed far enough for the set boiler water temperature required for cyl-
inder heating to be achieved. In that case, DHW cylinders qP and
heating circuits eP and rP will be heated simultaneously.

Heating mode
ID: 4605024_1001_02 Depending on the control unit used, the flow temperature of heating
circuits eP and rP can be operated in modulating mode subject to the
outside temperature. The boiler water temperature is regulated 8 K
Applications higher than the set flow temperature or the minimum boiler water tem-
Classic detached house and two-family home, DHW heating by solar perature of 60 C.
thermal system and pellet boiler, heating by the pellet boiler. The heating circuit pump is switched on via the heating circuit pump
logic, provided there is a heat demand.
Main components
Vitoligno 300-P DHW heating by the solar thermal system with Vitosolic (two
Heating circuit distributor with mixer heating circuits)
DHW cylinders (optional dual mode) For systems with two heating circuits with mixer or if additional solar
Solar thermal system (optional) control unit functions are required (e.g. heating the solar preheat stage
and switching the transfer pump), use a Vitosolic solar control unit.
Function description If Vitosolic 100 (type SD1) wZ is connected via the KM BUS to
The heating circuits eP and rP are regulated by the Vitotronic 200 Vitotronic 200 (type FO1) 2, solar control unit information (e.g. col-
(type FO1) 2 control unit of Vitoligno 300-P 1. The boiler will only lector temperature, cylinder temperature, solar pump hours run and
start if there is a demand from the DHW cylinder or from a heating solar yield) can be displayed on the Vitotronic 200 or the Vitotrol
circuit. The time program for heating operation and heating up of DHW 300.
cylinder qP is set at the boiler circuit control unit. If the temperature differential between collector temperature sensor
wQ and cylinder temperature sensor qT exceeds the start temperature
Return temperature raising facility differential, solar circuit pump wE starts, and DHW cylinder qP is
The boiler is equipped with a return temperature raising facility. The heated up.
boiler water temperature is monitored. When the minimum tempera- The pump is switched OFF if:
ture is not reached, the flow rate is reduced by connected mixer eR/ The actual temperature drops below the stop temperature differen-
5 rR. tial
Heating circuit pumps eE/rE start only when the boiler water temper- The electronic temperature limit is exceeded
ature lies above the set flow temperature. The temperature selected at the high limit safety cut-out (if installed)
is reached
DHW heating by the Vitoligno 300-S
The DHW is heated up when the set DHW temperature is not reached
at cylinder temperature sensor qT, subject to cylinder heating being
enabled by the time program. The boiler water temperature is regula-
ted to the set cylinder temperature + 15 K or the minimum boiler water
temperature of 60 C, and circulation pump for cylinder heating qE
starts if the boiler water temperature lies 7 K above the actual cylinder
water temperature.
5822 470 GB

166 VIESMANN System examples


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605024_1001_02


--26/S1--

60 60

--KM-Bus--
21 30 40

--S2--
--S1--
20
61
--2/20M2--
26
32 42
--R2--
--R1--

--230V--
--2/2M1-- --2/2M2--
22
33 43
--2/20M1-- --2/20M2--
34 44
--2/52M1-- --2/52M2--

23 ----26/R1--
WW

12 --2/28--
25

13 --
--2/21--

--20M1--
--52M1--

--52M2--
--20M2--
--230V--

16
--28--
--21--

8
--26/R2--

45
2
--2/1--

24 --
--KM-Bus--
--1--
--5--

--2M1--

--2M2--

--2/5-- 11

15 9
--26/S2--

KW 10 / 14 1
5

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605024_1001_02
Pos. Description Part no.
Heat source
1 Vitoligno 300-P with As per Viessmann pricelist
2 Vitotronic 200, type FO1 part of the standard delivery of pos. 1
rT Outside temperature sensor ATS part of the standard delivery of pos. 1
8 Safety equipment block with safety valve 7143 779
9 Expansion vessel As per Vitoset pricelist
DHW heating by the boiler
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS part of the standard delivery of pos. 1
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Vitoset pricelist
DHW heating by the solar thermal system
qR Dual mode DHW cylinder As per Viessmann pricelist
qT Cylinder temperature sensor SOL Standard delivery, pos. 26
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL Standard delivery, pos. 26
wW Solar-Divicon As per Viessmann pricelist
5822 470 GB

wE Solar circuit pump R1 part of the standard delivery of pos.


22
wR Circulation pump As per Vitoset pricelist
wT Automatic thermostatic mixing valve 7438 940

System examples VIESMANN 167


Solid fuel boiler (cont.)

ID: 4605024_1001_02
Pos. Description Part no.
wZ Vitosolic 100, type SD1 Z007 387
wU Junction box on-site
eP Heating circuit I on-site
eQ Extension kit for one heating circuit with mixer with 7267 627
eW Flow temperature sensor VTS (contact sensor)
and
eR Mixer motor DN 20 to 50, R to R1
or
eW Flow temperature sensor VTS M1 (heating circuit I)
Contact temperature sensor or 7267 633
Immersion temperature sensor 7267 632
and
eR Mixer motor M1 for flanged mixer and plug-in connector As per Viessmann pricelist
eE Heating circuit pump HKP M1 (heating circuit I) As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
rP Heating circuit II on-site
rQ Extension kit for one heating circuit with mixer with 7267 627
rW Flow temperature sensor VTS (contact sensor)
and
rR Mixer motor DN 20 to 50, R to R1
or
rW Flow temperature sensor VTS M2 (heating circuit II)
Contact temperature sensor or 7267 633
Immersion temperature sensor 7267 632
and
rR Mixer motor M2 for flanged mixer and plug-in connector As per Viessmann pricelist
rE Heating circuit pump HKP M2 (heating circuit II) As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
Accessories
zP Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
zQ Thermostat for underfloor heating system
5 Immersion thermostat 7151 728
System thermostat 7151 729
zW KM BUS distributor 7415 028
zE Vitohome 300 As per Viessmann pricelist
zR Central fault messaging system S on-site
zT Radio clock receiver 7450 563

5822 470 GB

168 VIESMANN System examples


Solid fuel boiler (cont.)

Electrical installation scheme

2 N
28 M ZP
1~ 12
L
N
21 M UPSB
1~ 13
L
N
50 230V, 50Hz 64
L
N
20 M HKP M1 33
1~
230 V/ 50 Hz

M1 L
N
52 M M1 34
1~
M1

N
52 M M2
1~ 44
M2

61 20
L
20 M HKP M2 43
1~
M2 N

N
40 230 V/ 50 Hz
L

26
L 21
N 20 230 V/ 50 Hz
15
R1 19
M
N 18 1~ R1 23
14
27
STB 16
R2 17
62 M
N 16 1~ R2 24
13
3 3
145 2 2 145
1 1 3
145 2 12
1 11
145 5
4 SOL 15
S2
Low voltage

3
S1 2 KOL 21
1
3
145 2
KM BUS 60 / 63
1
3
1 2
1 ATS 45 / 65
3
5 2
1 STS 11
3
2 2
M1 1 VTS M1 32
3
2 2
M2 1 VTS M2 42

ID: 4605024_1001_02
5822 470 GB

System examples VIESMANN 169


Solid fuel boiler (cont.)

5.13 Vitoligno 300-P with one or two heating circuits with mixer, heating water buffer cyl-
inder and DHW cylinder (optional with dual mode DHW cylinder and solar thermal system)
If the heating circuits are regulated via the Vitotronic 200 (type FO1)
2, heating circuit pumps M1 eE and M2 rE stop, and mixers M1
eR and M2 rR are closed, subject to absolute priority being enabled
(recommended).
With modulating priority, heating circuit pumps M1 eE and M2 rE
remain switched on, and mixers M1 eR and M2 rR are closed far
enough for the set boiler water temperature required for cylinder heat-
ing to be achieved. In that case, DHW cylinders qP and heating circuits
eP and rP will be heated simultaneously.

ID: 4605025_1001_02 Heating mode


Depending on the control unit used, the flow temperature of heating
circuits eP and rP can be operated in modulating mode subject to the
Applications outside temperature. The boiler water temperature is regulated 8 K
Classic detached house and two-family home, DHW heating by solar higher than the set flow temperature or the minimum boiler water tem-
thermal system and pellet boiler, heating by the pellet boiler. perature of 60 C.
The heating circuit pump is switched on via the heating circuit pump
Main components logic, provided there is a heat demand. Upon demand, the boiler is
Vitoligno 300-P operated with the required set boiler water temperature or the mini-
Return temperature raising facility mum boiler water temperature of 60 C.
Heating circuit distributor with mixer The boiler shuts down if neither the DHW cylinder nor the heating cir-
DHW cylinders (optional dual mode) cuits issue any more demands.
Heating water buffer cylinder
Solar thermal system (optional) DHW heating by the solar thermal system with Vitosolic
For systems with two mixer heating circuits or if additional solar control
Function description unit functions are required (e.g. heating the solar preheat stage and
The heating circuits eP and rP are regulated by the Vitotronic 200, switching the transfer pump), use a Vitosolic solar control unit.
type FO1 2 control unit of Vitoligno 300-P 1. The boiler will only If Vitosolic 100 (type SD1) is connected via the KM BUS to Vitotronic
start if there is a demand from the DHW cylinder or from a heating 200 (type FO1) , solar control unit information (e.g. collector temper-
circuit. The time program for heating operation and heating up of DHW ature, cylinder temperature, solar pump hours run and solar yield) can
cylinder qP is set at the boiler circuit control unit. be displayed on the Vitotronic 200 or the Vitotrol 300.
If the temperature differential between collector temperature sensor
Heating up the heating water buffer cylinder and raising the return wQ and cylinder temperature sensor qT exceeds the start temperature
temperature differential, solar circuit pump wE starts, and DHW cylinder qR is
5 The boiler and boiler circuit pump 5 start when the actual temperature heated up.
at buffer cylinder temperature sensor tQ or DHW cylinder qP falls The pump is switched OFF if:
below the temperature set for heating circuits eP and rP. The boiler The actual temperature drops below the stop temperature differen-
shuts down and the boiler circuit pump runs on for approx. 10 min. tial
when the actual temperature at buffer cylinder temperature sensor The electronic temperature limit is exceeded
tW falls below the temperature set for the heating circuits. Mixing valve The temperature selected at the high limit safety cut-out (if installed)
4 in the return temperature raising facility holds the boiler water return is reached
temperature at a minimum of 45 C. Set the water circulation volume
in the boiler circuit of the Vitoligno 300-P, so that a temperature spread
of 15 K between the boiler flow and return results at rated boiler out-
put.

DHW heating by the Vitoligno 300-S


The DHW is heated up when the set DHW temperature is not reached
at cylinder temperature sensor qQ, subject to cylinder heating being
enabled by the time program. The boiler water temperature is regula-
ted to the set cylinder temperature + 15 K or the minimum boiler water
temperature of 60 C. Circulation pump for cylinder heating qE starts,
when the heating water buffer cylinder temperature (top) lies 7 K above
the cylinder temperature.
5822 470 GB

170 VIESMANN System examples


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605025_1001_02


--26/S1--

60 60

--KM-Bus--
21 30

--S2--
--S1--
20 40
61
--2/20M2--
26
32 42
--R2--
--R1--

--230V--
--2/2M1-- --2/2M2--
22
33 43
--2/20M1-- --2/20M2--
34 44
--2/52M1-- --2/52M2--

23 ----26/R1--
WW

12 -- 53
--2/28--

25

13 -- 4
--2/21--

3 5
-2/29-
6
16
8 51
--26/R2--

--2/9 --

24 --
45
--2/5-- 11
--2/1--

52
15
9 --2/9 --
--26/S2--

KW 10 / 14
5
1 50
--20M1--
--52M1--

--52M2--
--20M2--
--230V--
--21--

--29--
--28--

2
--1--
--5--
-KM-Bus-
--2M1--

--2/9 --
--2/9 --
--2M2--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605025_1001_02
Pos. Description Part no.
Heat source
1 Vitoligno 300-P with As per Viessmann pricelist
2 Vitotronic 200, type FO1 part of the standard delivery of pos. 1
rT Outside temperature sensor ATS part of the standard delivery of pos. 1
3 Return temperature raising facility
12 to 24 kW 7373 302
32 to 48 kW 7373 303
4 Thermostatic control valve part of the standard delivery of pos. 3
5 Boiler circuit pump KKP part of the standard delivery of pos. 3
6 Temperature sensor part of the standard delivery of pos. 4
8 Safety equipment block with safety valve 7143 779
9 Expansion vessel As per Vitoset pricelist
5822 470 GB

System examples VIESMANN 171


Solid fuel boiler (cont.)

ID: 4605025_1001_02
Pos. Description Part no.
DHW heating by the boiler
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor STS part of the standard delivery of pos. 1
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Vitoset pricelist
DHW heating by the solar thermal system
qR Dual mode DHW cylinder As per Viessmann pricelist
qT Cylinder temperature sensor SOL Standard delivery, pos. 26
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL Standard delivery, pos. 26
wW Solar-Divicon As per Viessmann pricelist
wE Solar circuit pump R1 part of the standard delivery of pos.
22
wR Circulation pump As per Vitoset pricelist
wT Automatic thermostatic mixing valve 7438 940
wZ Vitosolic 100, type SD1 Z007 387
wU Junction box on-site
eP Heating circuit I on-site
eQ Extension kit for one heating circuit with mixer with 7267 627
eW Flow temperature sensor VTS (contact sensor)
and
eR Mixer motor DN 20 to 50, R to R1
or
eW Flow temperature sensor VTS M1 (heating circuit I)
Contact temperature sensor or 7267 633
Immersion temperature sensor 7267 632
and
eR Mixer motor M1 for flanged mixer and plug-in connector As per Viessmann pricelist
eE Heating circuit pump HKP M1 (heating circuit I) As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
rP Heating circuit II on-site
rQ Extension kit for one heating circuit with mixer with 7267 627
rW Flow temperature sensor VTS (contact sensor)
5 and
rR Mixer motor DN 20 to 50, R to R1
or
rW Flow temperature sensor VTS M2 (heating circuit II)
Contact temperature sensor or 7267 633
Immersion temperature sensor 7267 632
and
rR Mixer motor M2 for flanged mixer and plug-in connector As per Viessmann pricelist
rE Heating circuit pump HKP M2 (heating circuit II) As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
tP Heating water buffer cylinder As per Viessmann pricelist
tQ Buffer temperature sensor PTS above Z008 377
tW Buffer temperature sensor PTS bottom part of the standard delivery of pos.
51
tE Connection unit, heating water buffer cylinder 7159 406
Accessories
zP Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
zQ Thermostat for underfloor heating system
Immersion thermostat 7151 728
System thermostat 7151 729
zW KM BUS distributor 7415 028
zE Vitohome 300 As per Viessmann pricelist
zR Central fault messaging system S on-site
zT Radio clock receiver 7450 563
5822 470 GB

172 VIESMANN System examples


Solid fuel boiler (cont.)

Electrical installation scheme

2 N
29 M KKP
1~ 5
L
N
28 M ZP
1~ 12
L
N
21 M UPSB
1~ 13
L
N
50 230V, 50Hz 64
L
N
20 M HKP M1 33
1~
230 V/ 50 Hz

M1 L
N
52 M M1 34
1~
M1

N
52 M M2
1~ 44
M2

61 20
L
20 M HKP M2 43
1~
M2 N

N
40 230 V/ 50 Hz
L

26
L 21
N 20 230 V/ 50 Hz
15
R1 19
M
N 18 1~ R1 23
14
27
STB 16
R2 17
62 M
N 16 1~ R2 24
13
145
3
2
3
2 145 5
1 1 3
145 2 12
145
1 11
4 SOL 15
S2
Low voltage

3
S1 2 KOL 21
1
3
145 2
KM BUS 60 / 63
1
3
1 2
1 ATS 45 / 65
3
5 2
1 STS 11
3
2 2
M1 1 VTS M1 32
3
2 2
M2 1 VTS M2 42
3
9 2
1 PTS 51
3
9 2
1 PTS 52

ID: 4605025_1001_02
5822 470 GB

System examples VIESMANN 173


Solid fuel boiler (cont.)

5.14 Vitoligno 300-P with one or two heating circuits with mixer, solar buffer cylinder (for
solar central heating backup) and DHW cylinder (optional with dual mode DHW cylinder
and solar thermal system with Vitosolic 200)
With modulating priority, heating circuit pumps M1 eW and M2 rE
remain switched on, and mixers M1 eE and M2 rR are closed far
enough for the set boiler water temperature required for cylinder heat-
ing to be achieved. In that case, DHW cylinders qP and heating circuits
eP and rP will be heated simultaneously.

Heating mode
Depending on the control unit used, the flow temperature of heating
circuits eP and rP can be operated in modulating mode subject to the
outside temperature. The boiler water temperature is regulated 8 K
ID: 4605026_1001_02 higher than the set flow temperature or the minimum boiler water tem-
perature of 60 C.
The heating circuit pump is switched on via the heating circuit pump
Applications logic, provided there is a heat demand. Upon demand, the boiler is
DHW heating and central heating backup by the solar thermal system; operated with the required set boiler water temperature or the mini-
DHW heating by the pellet boiler. mum boiler water temperature of 60 C.
The boiler shuts down if neither the DHW cylinder nor the heating cir-
Main components cuits issue any more demands.
Vitoligno 300-P
Return temperature raising facility Control of a solar thermal system
Heating circuit distributor with mixer The Vitosolic 200 (type SD4) wZ control unit regulates the DHW heat-
DHW cylinders (optional dual mode) ing by solar energy and central heating with backup from the solar
Solar buffer cylinder thermal system.
Solar thermal system (optional)
DHW heating by the solar thermal system
Function description If the temperature differential between collector temperature sensor
The heating circuits eP and rP are regulated by the Vitotronic 200, wQ and cylinder temperature sensor qT exceeds the temperature dif-
type FO1 2 control unit of Vitoligno 300-P 1. The boiler will only ferential Ton, solar circuit pump wE starts. The pump wE stops if:
start if there is a demand from the DHW cylinder or from a heating The actual temperature falls below the temperature differential
circuit. The time program for heating operation and heating up of DHW TOFF
cylinder qP is set at the boiler circuit control unit. The actual value exceeds the electronic temperature limit (max. 95
C) at the control unit or that selected at the high limit safety cut-out
5 Heating up the solar buffer cylinder and raising the return tem- (if required).
perature
The boiler and boiler circuit pump 5 start when the actual temperature Central heating/central heating backup by the solar thermal sys-
at buffer cylinder temperature sensor tQ or DHW cylinder qP falls tem
below the temperature set for heating circuits eP and rP. The boiler If the DHW cylinder cannot be heated and the temperature differential
shuts down and the boiler circuit pump runs on for approx. 10 min. between collector temperature sensor wQ and buffer temperature sen-
when the actual temperature at buffer cylinder temperature sensor sor tE exceeds temperature differential T2on, circulation pump wO
tW falls below the temperature set for the heating circuits. Mixing valve starts to heat the heat exchanger. The pump will be stopped if the
4 in the return temperature raising facility holds the boiler water return actual temperature falls below the temperature differential T2OFF or
temperature at a minimum of 45 C. Set the water circulation volume
it reaches the maximum buffer cylinder temperature Tcyl2max. The tem-
in the boiler circuit of the Vitoligno 300-P, so that a temperature spread
of 15 K between the boiler flow and return results at rated boiler out- perature inside the heating water buffer cylinder will be electronically
put. limited by the high limit safety cut-out (if required). This stops circula-
tion pump wO when the set temperature has been exceeded. The run-
DHW heating by the Vitoligno 300-S time of circulation pump wO is interrupted for approx. 2 min roughly
The DHW is heated up when the set DHW temperature is not reached every 15 min (times are adjustable), to check that the temperature at
at cylinder temperature sensor qQ, subject to cylinder heating being the collector temperature sensor is high enough to change over to
enabled by the time program. The boiler water temperature is regula- DHW cylinder heating. The DHW cylinder will continue to be heated if,
ted to the set cylinder temperature + 15 K or the minimum boiler water during that time, value T-Col is exceeded.
temperature of 60 C. Circulation pump for cylinder heating qE starts,
when the heating water buffer cylinder temperature (top) lies 7 K above
the cylinder temperature.
If the heating circuits are regulated via the Vitotronic 200, type FO1
2, heating circuit pumps M1 eE and M2 rE stop, and mixers M1
eR and M2 rR are closed, subject to absolute priority being enabled
(recommended).
5822 470 GB

174 VIESMANN System examples


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605026_1001_02

--26/S1--

--KM-Bus--
60 60

--S2--
--S1--

--S4--
Vorlauf

21 26 30 40
20
61

--R4--
--R5--
--R1--

--230V--
Ruecklauf
--2/20M2--
32 42
--2/2M1-- --2/2M2--
28 22
33 43
--2/20M1-- --2/20M2--
34 44
--2/52M1-- --2/52M2--

29
--- 23 ---26/R1--
--26/R4--

WW

25 12 --
4
--2/28--

5
13 -- 3
--2/21--

--2/29-- 54
6
16
8 --2/9 --
--26/R5--

51
24
----- 52
11 --2/9 --
--2/5-- 45

15 --26/S4--
--2/1--

9
--26/S2-- 53

KW 10 / 14 1 50 5
--52M2--
--52M1--
--20M1--

--20M2--
--230V--
--28--
--21--

--29--

2
--1--
--2M1--
--5--
-KM-Bus--
--9 --
--9 --
--2M2--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605026_1001_02
Pos. Description Part no.
Heat source
1 Vitoligno 300-P As per Viessmann pricelist
2 Vitotronic 200, type FO1 part of the standard delivery of pos. 1
rT Outside temperature sensor ATS part of the standard delivery of pos. 1
3 Return temperature raising facility
12 to 24 kW 7373 302
32 to 48 kW 7373 303
4 Thermostatic control valve part of the standard delivery of pos. 3
5 Boiler circuit pump KKP part of the standard delivery of pos. 3
6 Temperature sensor part of the standard delivery of pos. 4
8 Safety equipment block with safety valve 7143 779
5822 470 GB

9 Expansion vessel As per Vitoset pricelist

System examples VIESMANN 175


Solid fuel boiler (cont.)

ID: 4605026_1001_02
Pos. Description Part no.
DHW heating by the boiler
qP DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor SOL part of the standard delivery of pos. 1
qW DHW circulation pump ZP As per Vitoset pricelist
qE Circulation pump for cylinder heating UPSB As per Vitoset pricelist
DHW heating by the solar thermal system
qR DHW cylinder, dual mode As per Viessmann pricelist
qT Cylinder temperature sensor STS, heating by solar energy part of the standard delivery of pos.
26
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL part of the standard delivery of pos.
26
wW Solar-Divicon As per Viessmann pricelist
wE Solar circuit pump R1 part of the standard delivery of pos.
22
wR Circulation pump UP As per Vitoset pricelist
wT Automatic thermostatic mixing valve 7438 940
wZ Vitosolic 200, type SD4 Z007 388
wU Junction box on-site
wI Solar pump line As per Viessmann pricelist
wO Circulation pump UP Solar part of the standard delivery of pos.
28
eP Heating circuit I on-site
eQ Extension kit for one heating circuit with mixer with 7267 627
eW Flow temperature sensor (contact sensor)
and
eR Mixer motor DN 20 to 50, R to R1
or
eW Flow temperature sensor VTS M1 (heating circuit I)
Contact temperature sensor or 7267 633
Immersion temperature sensor 7267 632
and
eR Mixer motor for flanged mixer and plug-in connector As per Viessmann pricelist
eE Heating circuit pump HKP M1 (heating circuit I) As per Vitoset pricelist
5 or
Divicon As per Viessmann pricelist
rP Heating circuit II on-site
rQ Extension kit for one heating circuit with mixer with 7267 627
rW Flow temperature sensor (contact sensor)
and
rR Mixer motor DN 20 to 50, R to R1
or
rW Flow temperature sensor VTS M2 (heating circuit II)
Contact temperature sensor or 7267 633
Immersion temperature sensor 7267 632
and
rR Mixer motor for flanged mixer and plug-in connector As per Viessmann pricelist
rE Heating circuit pump HKP M2 (heating circuit II) As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
tP Solar buffer cylinder As per Viessmann pricelist
tQ Buffer temperature sensor PTS above Z008 377
tW Buffer temperature sensor PTS bottom part of the standard delivery of pos.
51
tE Buffer temperature sensor PTS solar part of the standard delivery of pos.
26
tR High limit safety cut-out STB Z001 889
5822 470 GB

176 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605026_1001_02
Pos. Description Part no.
Accessories
zP Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
zQ Thermostat for underfloor heating system
Immersion thermostat 7151 728
System thermostat 7151 729
zW KM BUS distributor 7415 028
zE Vitohome 300 As per Viessmann pricelist
zR Central fault messaging system S on-site
zT Radio clock receiver 7450 563

5
5822 470 GB

System examples VIESMANN 177


Solid fuel boiler (cont.)

Electrical installation scheme

2 N
29 M KKP
1~ 5
L
N
28 M ZP
1~ 12
L
N
21 M UPSB
1~ 13
L
N
50 230V, 50Hz 64
L
N
20 M HKP M1 33
1~
230 V/ 50 Hz

M1 L
N
52 M M1 34
1~
M1

N
52 M M2
1~ 44
M2

61 20
L
20 M HKP M2 43
1~
M2 N

N
40 230 V/ 50 Hz
L

26
L
N 230 V/ 50 Hz

R1
M
N 1~ R1 23
27
STB 16

R4
M
N 1~ UP SOL 29
5 27
STB 54

R5
M
N 1~ UP 24

S4 PTS 53
62
S2 SOL 15
3 3
145 2 2 145 S1 KOL 21
1 1 3
145 2 12
145
1 11
Low voltage

3
145 2
KM BUS 60 / 63
1
3
1 2
1 ATS 45 / 65
3
5 2
1 STS 11
3
2 2
M1 1 VTS M1 32
3
2 2
M2 1 VTS M2 42
3
9 2
1 PTS 51
3
9 2
PTS 52
5822 470 GB

ID: 4605026_1001_02

178 VIESMANN System examples


Solid fuel boiler (cont.)

5.15 Vitolig 300-P with one or two heating circuits with mixer, multi-mode heating water
buffer cylinder and solar thermal system
Heating up the heating water buffer cylinder and raising the return
temperature
Boiler 1 and boiler circuit pump 5 start when the actual temperature
at buffer cylinder temperature sensor tQ falls below the temperature
set for heating circuits eP/rP or cylinder qR. The boiler shuts down
and the boiler circuit pump runs on for approx. 10 min. when the actual
temperature at buffer cylinder temperature sensor tW falls below the
temperature set for the heating circuits. Mixing valve 4 in the return
temperature raising facility holds the boiler water return temperature
at a minimum of 45 C. Set the water circulation volume in the boiler
ID: 4605027_1001_02 circuit of the Vitoligno 300-P, so that a temperature spread of 15 K
between the boiler flow and return results at rated boiler output.

Applications Central heating by the Vitoligno 300-P and solar thermal system
DHW heating and central heating backup by the solar thermal system; The multi-mode heating water buffer cylinder Vitocell 340-M or 360-M
DHW and central heating by the pellet boiler. is heated by the solar thermal system. The boiler remains shut down
if the solar thermal system can provide sufficient heat.
Main components
Vitoligno 300-P DHW heating without solar energy
Return temperature raising facility The top part of the combi cylinder is heated by the boiler. The integral
Heating circuit distributor with mixer instantaneous water heater/standby section is heated by the surround-
Multi-mode heating water buffer cylinder Vitocell 340-M or 360-M ing buffer cylinder water. On demand, the cylinder thermostat with cyl-
with integral DHW heating inder temperature sensor qQ switches 3-way diverter valve qO over
towards cylinder/standby part.
Function description
The heating circuits eP and rP are regulated by the Vitotronic 200, DHW heating with solar energy
type FO1 2 control unit of Vitoligno 300-P 1. The boiler will only If a temperature differential between the collector temperature sensor
start if there is a demand for DHW heating or from a heating circuit. wQ and cylinder temperature sensor qT is captured that is higher than
The time program for heating operation and heating up of the multi- the temperature differential set on the control unit, solar circuit pump
mode heating water buffer cylinder qR is set at the boiler circuit control wE starts and cylinder qR will be heated. For this, the temperature
unit. inside the cylinder will be limited by electronic temperature limiter wZ
The heating circuit pumps are switched on via the heating circuit pump in the Vitosolic 100. This stops the solar circuit pump wE when the set
logic, provided there is a heat demand. temperature is exceeded. The electronic temperature limiter is preset
Mixing valve 4 in the return temperature raising facility holds the at the factory to 60 C and can be adjusted.
boiler water return temperature at a minimum of 45 C. Set the water The entire cylinder is heated by the solar thermal system if the inso-
5
circulation volume of the boiler circuit 1, so that a temperature spread lation is adequate for heating the DHW. The top part of the cylinder will
of 15 K between the boiler flow and return results at rated boiler output. only be reheated by the boiler if the temperature of the water falls below
The boiler shuts down if neither the multi-mode heating water buffer the temperature set at Vitotronic 200 2.
cylinder qR nor the heating circuits eP and rP issue any demands. The DHW in the lower area of the cylinder is preheated by solar energy
Upon demand, the boiler is operated with the required set boiler water and the top section is heated to the required temperature by the boiler
temperature or the minimum boiler water temperature of 60 C. Any if the insolation level is inadequate.
DHW demand is given priority; this causes the heating circuit pumps
eE/rE to be stopped and the mixers eR/rR to be closed. When the set
DHW cylinder temperature is reached, the system changes over to
heating the heating circuits eP/rP.
Boiler 1 and boiler circuit pump 5 start when the actual temperature
at buffer cylinder temperature sensor tQ falls below the set heating
circuit temperature. The boiler shuts down and the boiler circuit pump
runs on for approx. 10 min. when the actual temperature at buffer cyl-
inder temperature sensor falls approx. 6 K below the temperature set
for the heating circuits.
5822 470 GB

System examples VIESMANN 179


Solid fuel boiler (cont.)

Hydraulic installation scheme ID: 4605027_1001_02


--26/S1--

--KM-Bus--
60 60

--S2--
--S1--
Vorlauf

21 26 30 40
20
61

--R1--

--230V--
Ruecklauf
--2/20M2--
32 42
--2/2M1-- --2/2M2--
22
33 43
--2/20M1-- --2/20M2--
34 44
--2/52M1-- --2/52M2--

23 ---26/R1-

WW

12 --
--2/28--

4
25 5
3
--2/29--
16
-26/R1- HV1 6
WW/Z 18 8
11 A
-2/5- SPR1 -2/21-
AB
51 HV2/HR1 B
SPR2 19
-2/9 - HR2
52
-2/9 - SPR3 HR3
15 KW 9
-26/S2- E 45
HVs/HRs
--2/1--

5 14 1

KW
--52M2--
--52M1--
--20M1--

--20M2--
--230V--
--21--
--28--

--29--

2
--1--

--5--
-KM-Bus-

--2M1--
--9 --
--9 --

--2M2--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

Equipment required

ID: 4605027_1001_02
Pos. Description Part no.
Heat source
1 Vitoligno 300-P As per Viessmann pricelist
2 Vitotronic 200, type FO1 part of the standard delivery of pos. 1
rT Outside temperature sensor ATS part of the standard delivery of pos. 1
3 Return temperature raising facility
12 to 24 kW 7373 302
32 to 48 kW 7373 303
4 Thermostatic control valve part of the standard delivery of pos. 3
5 Boiler circuit pump KKP part of the standard delivery of pos. 3
6 Temperature sensor part of the standard delivery of pos. 4
8 Safety equipment block with safety valve 7143 779
5822 470 GB

9 Expansion vessel As per Vitoset pricelist

180 VIESMANN System examples


Solid fuel boiler (cont.)

ID: 4605027_1001_02
Pos. Description Part no.
qR Vitocell 340-M/360-M As per Viessmann pricelist
qQ Cylinder temperature sensor STS part of the standard delivery of pos. 1
qW DHW circulation pump ZP As per Vitoset pricelist
qI Threaded DHW circulation fitting 7198 542
qO 3-way diverter valve for cylinder heating (up to 32 kW) 7814 924
(for higher output: on-site provision)
tQ Buffer temperature sensor PTS above Z008 377
tW Buffer temperature sensor PTS bottom part of the standard delivery of pos.
51
Cylinder heating by the solar thermal system
qT Cylinder temperature sensor SOL part of the standard delivery of pos.
26
qZ High limit safety cut-out STB Z001 889
wP Solar collectors As per Viessmann pricelist
wQ Collector temperature sensor KOL part of the standard delivery of pos.
26
wW Solar-Divicon As per Viessmann pricelist
wE Solar circuit pump R1 part of the standard delivery of pos.
22
wT Automatic thermostatic mixing valve 7438 940
wZ Vitosolic 100, type SD1 Z007 387
eP Heating circuit I on-site
eQ Extension kit for one heating circuit with mixer with 7267 627
eW Flow temperature sensor (contact sensor)
and
eR Mixer motor DN 20 to 50, R to R1
or
eW Flow temperature sensor VTS M1 (heating circuit I)
Contact temperature sensor or 7267 633
Immersion temperature sensor 7267 632
and
eR Mixer motor for flanged mixer and plug-in connector As per Viessmann pricelist
eE Heating circuit pump HKP M1 (heating circuit I) As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
rP Heating circuit II on-site 5
rQ Extension kit for one heating circuit with mixer with 7267 627
rW Flow temperature sensor (contact sensor)
and
rR Mixer motor DN 20 to 50, R to R1
or
rW Flow temperature sensor VTS M2 (heating circuit II)
Contact temperature sensor or 7267 633
Immersion temperature sensor 7267 632
and
rR Mixer motor for flanged mixer and plug-in connector As per Viessmann pricelist
rE Heating circuit pump HKP M2 (heating circuit II) As per Vitoset pricelist
or
Divicon As per Viessmann pricelist
Accessories
zP Vitotrol 200 7450 017
or
Vitotrol 300 7248 907
zQ Thermostat for underfloor heating system
Immersion thermostat 7151 728
System thermostat 7151 729
zW KM BUS distributor 7415028
zE Vitohome 300 As per Viessmann pricelist
zR Central fault messaging system S on-site
zT Radio clock receiver 7450 563
5822 470 GB

System examples VIESMANN 181


Solid fuel boiler (cont.)

Electrical installation scheme

2 N
29 M KKP
1~ 5
L
N
28 M ZP
1~ 12
L
N
21 M
1~ 19
L
N
50 230V, 50Hz 64
L
N
20 M HKP M1 33
1~
230 V/ 50 Hz

M1 L
N
52 M M1 34
1~
M1

N
52 M M2
1~ 44
M2

61 20
L
20 M HKP M2 43
1~
M2 N

N
40 230 V/ 50 Hz
L

26
L
N 230 V/ 50 Hz

R1
M
N 1~ R1 23
27
STB 16

62
5 3 3
S2 SOL 15

145 2 2 145 S1 KOL 21


1 1 3
145 2 12
145
1 11
Low voltage

3
145 2
KM BUS 60 / 63
1
3
1 2
1 ATS 45 / 65
3
5 2
1 STS 11
3
2 2
M1 1 VTS M1 32
3
2 2
M2 1 VTS M2 42
3
9 2
1 PTS 51
3
9 2
1 PTS 52

ID: 4605027_1001_02
5822 470 GB

182 VIESMANN System examples


Solar thermal systems

6.1 Overview of sample applications


Solar thermal: Chapter 6, page 183
DHW heating with dual mode DHW cylinder, with Vitosolic 100 DHW heating with dual mode DHW cylinder, central heating backup
See page 189 with heating water buffer cylinder, with Vitosolic 200
See page 205

ID: 4605154_1001_01 ID: 4605156_1001_01


Vitodens / Vitoladens DHW heating and central heating backup with DHW heating with mono-mode DHW cylinders, with Vitosolic 200
a multi-mode heating water buffer cylinder, with solar control module See page 209
See page 192

ID: 4605029_1001_03 ID: 4605157_1001_01


Vitodens / Vitoladens DHW heating with freshwater module, central DHW heating and swimming pool water heating with dual mode DHW
heating backup with a heating water buffer cylinder, with solar control cylinder, with Vitosolic 200
module See page 213
See page 196

ID: 4605030_1001_03 ID: 4605158_1001_01 6


DHW heating with solar retrofit system, incl. Vitosolic 100 DHW heating, central heating backup with a multi-mode heating water
See page 201 buffer cylinder, with Vitosolic 200
See page 217

ID: 4605155_1001_01 ID: 4605159_1001_01


5822 470 GB

System examples VIESMANN 183


Solar thermal systems (cont.)

DHW heating, central heating backup with a multi-mode heating water Large solar thermal systems DHW heating, with Vitosolic 200
buffer cylinder, with solar control module See page 233
See page 221

ID: 4605160_1001_01 ID: 4605163_1001_01


DHW heating with freshwater module and central heating backup with Large solar thermal systems DHW heating with two mono-mode
a heating water buffer cylinder, with Vitosolic 200 DHW cylinders and central heating backup with a heating water buffer
See page 224 cylinder, with Vitosolic 200
See page 237

ID: 4605161_1001_01 ID: 4605164_1001_01


DHW heating with mono-mode DHW cylinder, central heating backup
with multi-mode heating water buffer cylinder, with Vitosolic 200
See page 229

ID: 4605162_1001_01

6 5822 470 GB

184 VIESMANN System examples


Solar thermal systems (cont.)

Boiler floorstanding, 18 to 100 kW with solar thermal system: Chapter 2, page 7


One heating circuit without mixer or DHW heating (optional solar DHW One heating circuit without mixer and two heating circuits with mixer
heating with Vitosolic 100) and DHW heating (optional solar DHW heating with Vitosolic 100)
See page 8 See page 21

ID: 4605000_1001_04 ID: 4605002_1001_04


One heating circuit without mixer, one heating circuit with mixer and
DHW heating (optional solar DHW heating with Vitosolic 100)
See page 12

ID: 4605001_1001_04

Boiler wall mounted, 3.8 to 35 kW with solar thermal system: Chapter 3, page 25
One heating circuit without mixer and solar control module Without/with mixer, system separation or sub-mounting kit and solar
See page 26 control module
See page 36

ID: 4605131_1001_01 ID: 4605133_1001_01 6


One heating circuit with mixer and solar control module Injection circuit (Vitopend 200-W only) and solar control module
See page 31 See page 43

ID: 4605132_1001_01 ID: 4605006_1001_03


5822 470 GB

System examples VIESMANN 185


Solar thermal systems (cont.)

One heating circuit without mixer, two heating circuits with mixer and Without/with mixer, system separation and integral solar control mod-
solar control module ule
See page 48 See page 64

ID: 4605134_1001_01 ID: 4605137_1001_01


One heating circuit without mixer and integral solar control module With mixer and low loss header, without/with system separation and
See page 54 integral solar control module
See page 69

ID: 4605135_1001_01 ID: 4605138_1001_01


Two heating circuits with mixer, low loss header and integral solar con-
trol module
See page 59

ID: 4605136_1001_01

Boiler wall mounted, 45 to 105 kW with solar thermal system: Chapter 4, page 74
Three or more heating circuits with mixer, low loss header and solar
6 control module
See page 103

ID: 4605144_1001_01
5822 470 GB

186 VIESMANN System examples


Solar thermal systems (cont.)

Solid fuel boiler with solar thermal system: Chapter 5, page 109
Vitoligno 100-S with one or more heating circuits with mixer, heating Vitoligno 100-S with wall mounted oil or gas boiler, one or several
water buffer cylinder and DHW heating (optional solar DHW heating heating circuits with mixer, heating water buffer cylinder, multi-mode
with Vitosolic 100) heating water buffer cylinder and solar control module
See page 111 See page 134

ID: 4605017_1001_02 ID: 4605078_1001_02


Vitoligno 100-S and oil/gas boiler with one or more heating circuits with Vitolig 200 with one or two heating circuits with mixer, heating water
mixer, heating water buffer cylinder and DHW heating (optional solar buffer cylinder, DHW cylinder and Vitosolic 100
DHW heating with Vitosolic 100) See page 139
See page 115

ID: 4605018_1001_02 ID: 4605021_1001_03


Vitoligno 100-S and wall mounted oil/gas boiler with one or several Vitolig 200 with oil/gas boiler, one or two heating circuits with mixer,
heating circuits with mixer, heating water buffer cylinder and DHW heating water buffer cylinder and Vitosolic 200
heating (optional solar DHW heating with solar control module) See page 143
See page 122

ID: 4605019_1001_02 ID: 4605150_1001_01


Vitoligno 100-S with oil/gas boiler, one or several heating circuits with Vitolig 200 with wall mounted oil/gas boiler and one or two heating
6
mixer, heating water buffer cylinder, multi-mode heating water buffer circuits with mixer, heating water buffer cylinder and solar control mod-
cylinder and Vitosolic 200 ule
See page 130 See page 149

ID: 4605020_1001_02 ID: 4605151_1001_01


5822 470 GB

System examples VIESMANN 187


Solar thermal systems (cont.)

Vitolig 200 with oil/gas boiler, one or two heating circuits with mixer, Vitoligno 300-P with one or two heating circuits with mixer, heating
heating water buffer cylinder, multi-mode heating water buffer cylinder water buffer cylinder and DHW heating (optional solar DHW heating
and Vitosolic 200 with Vitosolic 100)
See page 156 See page 170

ID: 4605152_1001_01 ID: 4605025_1001_02


Vitolig 200 with wall mounted oil/gas boiler, one or two heating circuits Vitoligno 300-P with one or two heating circuits with mixer, solar buffer
with mixer, heating water buffer cylinder, multi-mode heating water buf- cylinder (for solar central heating backup) and DHW cylinder (optional
fer cylinder and solar control module solar DHW heating with Vitosolic 200)
See page 161 See page 174

ID: 4605153_1001_01 ID: 4605026_1001_02


Vitoligno 300-P with one or two heating circuits with mixer, DHW cylin- Vitolig 300-P with one or two heating circuits with mixer, multi-mode
der (optional solar DHW heating with Vitosolic 100) heating water buffer cylinder and solar thermal system with Vitosolic
See page 166 100
See page 179

ID: 4605024_1001_02 ID: 4605027_1001_02

6 5822 470 GB

188 VIESMANN System examples


Solar thermal systems (cont.)

6.2 DHW heating with dual mode DHW cylinder, with Vitosolic 100
Solar circuit pump R1 eE stops if:
The actual temperature drops below the stop temperature differen-
tial
The electronic temperature limit (max. at 90 C) set at control unit
eZ is exceeded
The temperature selected at high limit safety cut-out (STB) qW (if
installed) is reached

Additional function for DHW heating


The requirements for the auxiliary function (see "Vitosol" technical
ID: 4605154_1001_01 guide) are met by circulation pump R2 qT.

Suppression of DHW cylinder reheating by the boiler


Main components Coding address 67 in boiler circuit control unit 2 defaults a third set
Viessmann solar collectors DHW temperature (setting range 10 to 95 C). This value must be
DHW cylinders Vitocell 100-B or Vitocell 300-B below the first set DHW temperature. DHW cylinder qP will only be
Vitosolic 100, type SD1 heated by boiler 1 (solar circuit pump R1 eE runs) if this set value
Solar-Divicon cannot be achieved by the solar thermal system.
Oil/gas boilers
DHW heating without solar energy
Function description The upper section of DHW cylinder qP is heated by boiler 1. The
cylinder thermostat with cylinder temperature sensor 3 of boiler cir-
DHW heating with solar energy cuit control unit 2 switches the circulation pump for cylinder heat-
Solar circuit pump R1 eE starts, if the temperature differential between ing 4.
collector temperature sensor S1 eQ and cylinder temperature sensor
S2 qQ exceeds the start temperature differential, and DHW cylin-
der qP will be heated.

6
5822 470 GB

System examples VIESMANN 189


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605154_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--
30

36
Ruecklauf

--R1--
--R2--
--230V--
32

--2/21--
4

33 ---36/R1--
WW

14 13 --2/28--
-36/R1-

12
3
--36/R2--

--2/5--

15 --

11
--36/S2--

KW 10 1
--5--

2
--21--
--28--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
5822 470 GB

190 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605154_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
qP Dual mode DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump ZP As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
qT Circulation pump R2 (transfer) As per Vitoset pricelist
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 100, type SD1 Z007 387
eU Junction box on-site
eI ON/OFF switch on-site
For boiler and heating circuit accessories, see boiler scheme

Electrical installation scheme

eZ eI

21
20 230 V / 50 Hz
? 15
230 V / 50 Hz

eU
19
18 M R1 eE
1~
? 14

STB qW

17 6
16 M R2 qT
1~
? 13

145 12 KM BUS 2
11
10
9
Low voltage

6
5
4
3 SOL qQ

2
KOL eQ
1
5822 470 GB

ID: 4605154_1001_01

System examples VIESMANN 191


Solar thermal systems (cont.)

6.3 Vitodens / Vitoladens DHW heating and central heating backup with a multi-mode
heating water buffer cylinder, with solar control module
The burner is started via cylinder temperature sensor qZ of the boiler
circuit control unit, and 3-way diverter valve rZ changes to position
"AB-A". When the set DHW temperature has been reached, the burner
stops and 3-way diverter valve rZ changes to position "AB-B".

Suppression of reheating of the heating water buffer cylinder by


the boiler in conjunction with solar control module (type SM1)
Reheating suppression takes place in two stages.
Reheating of heating water buffer cylinder qP by boiler 1 is sup-
pressed, as soon as heating water buffer cylinder qP is heated by col-
ID: 4605029_1001_03 lectors eP. For this, the set DHW temperature for reheating is reduced
by boiler 1. Suppression remains active for a certain time after solar
circuit pump eE has been switched off.
Main components In the case of uninterrupted heating by collectors eP (> 2 h) boiler
Viessmann solar collectors 1 will only reheat, if the set cylinder temperature (coding address
Vitocell 340-M or Vitocell 360-M multi-mode heating water buffer "67") selected at boiler circuit control unit 2 is not achieved.
cylinder with integral DHW heating, with or without transfer system In control unit 2, coding address "67" defaults a third set DHW tem-
Solar control module, type SM1 perature (setting range 10 to 95 C). This value must be below the first
Solar-Divicon set DHW temperature.
Wall mounted oil/gas boiler from the year of manufacture 2010 Heating water buffer cylinder qP will only be heated by boiler 1, if this
onwards set value cannot be achieved by the solar thermal system.
Vitodens 200-W, type WB2C
Vitodens 300-W, type WB3D Suppression of reheating by the boiler in the case of central heat-
Vitoladens 300-W, type VP3C ing backup
If the temperature inside heating water buffer cylinder qP is adequate
Function description for heating the heating circuit, reheating by boiler 1 can be sup-
pressed.
DHW heating with solar energy
Solar circuit pump eE starts, if the temperature differential between DHW heating without solar energy
collector temperature sensor eQ and cylinder temperature sensor qQ The upper area of heating water buffer cylinder qP is heated by boiler
exceeds the start temperature differential, and heating water buffer 1. The integral instantaneous water heater/standby section is heated
cylinder qP will be heated. by the surrounding buffer cylinder water.
Solar circuit pump eE stops if: The cylinder thermostat with cylinder temperature sensor qZ of boiler
The actual temperature drops below the stop temperature differen- circuit control unit 2 switches 3-way diverter valve rZ.
tial
The electronic temperature limit (max. at 90 C) set at control unit Central heating with solar energy
eZ is exceeded If the temperature at sensor qT is sufficient, central heating takes
The temperature selected at high limit safety cut-out (STB) qW (if place.
installed) is reached
Entire heating water buffer cylinder qP is heated by the solar thermal Central heating without solar energy
system if the insolation is sufficient for this. If the temperature at sensor qT is inadequate, the burner and circula-
The upper section of heating water buffer cylinder qP will only be tion pump in the Vitodens are started. The section between HV2/HR1
6 reheated by boiler 1 if the set temperature selected at boiler circuit and HR2 inside the heating water buffer cylinder qP is heated to the
control unit 2 is not reached. set value for the weather-compensated operation of the heating cir-
If the solar energy is inadequate to cover the entire heating demand, cuits. When this set temperature is exceeded, the burner and, after a
the DHW in the lower section of heating water buffer cylinder qP will delay, the circulation pump in the Vitodens are stopped.
be preheated by solar energy. The DHW in the upper part of the cyl-
inder is heated to the required temperature by boiler 1.

Codes required on the boiler and heating circuit control unit

Code Function
51:2 The internal circulation pump is only switched on when the burner has been started (time delay off)
(if the coding address
exists)
53:3 System without DHW circulation pump: (only for the Vitodens)
The 3-way diverter valve rZ is connected to output sK of the internal extension H1 or H2
5b:1 Internal diverter valve without function
(DHW cylinder connected downstream of 3-way diverter valve rZ)
5822 470 GB

192 VIESMANN System examples


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605029_1001_03


--36/6--

--KM-Bus--
Vorlauf

31
30

--6--
--5--
36
Ruecklauf

--24--
--230V--
32

--x/x--
46
A
B
AB

33 ----36/24--
WW

13 --x/x--
14

16 HV1
--2/5-- WW/Z
12 SPR1 22
--36/24--
HV2/HR1
15 SPR2
--2/X3-- HR2
11 SPR3
HR3
--36/5-- 1
KW
E
HVs/HRs
-KM-Bus-

-KM-Bus-

KW 10
--X3--
--5--

2 3 4 5
--28--

--A2--
--A1--
-230V-

-230V-
--96--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
6
Note
For the electrical connection x/x:
Subject to equipment level, DHW circulation pump ZP qE and 3-way
diverter valve rZ are connected either at internal extension H1 3/ H2
4 or at extension AM1 5.
5822 470 GB

System examples VIESMANN 193


Solar thermal systems (cont.)

Equipment required

ID: 4605029_1001_03
Pos. Description Part no.
1 Wall mounted oil/gas boiler As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Internal extension H1 (standard delivery for the Vitodens 300-W) 7179 057
or
4 Internal extension H2 7179 144
or
System with DHW circulation or with the Vitoladens 300-W:
5 Extension AM1 7429 152
6 KM BUS distributor, for several KM BUS subscribers 7415 028
qP Multi-mode heating water buffer cylinder As per Viessmann pricelist
with
wW Threaded DHW circulation fitting 7198 542
qT Temperature sensor (flow temperature sensor for low loss header; in this scheme with heating 7179 488
water buffer cylinder)
qZ Cylinder temperature sensor STS 7179 114
qQ Cylinder temperature sensor (SOL) part of the standard delivery of pos.
36
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump ZP As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump part of the standard delivery of pos.
32
eZ Solar control module, type SM1 7429 073
eU Junction box on-site
eI ON/OFF switch on-site
rZ 3-way diverter valve 7814 924
For boiler and heating circuit accessories, see boiler scheme

6 5822 470 GB

194 VIESMANN System examples


Solar thermal systems (cont.)

Electrical installation scheme

Wall mounted gas boiler circuit control unit and solar control module

3
2 38
2 L
N
96
40 230 V/ 50 Hz 96 N
L
230 V/ 50 Hz

N
53 L
L
96 96 3 4 1
N
N
28 M
1~ ZP 13 46
40 5 L

2 L
96
5 STS 16 96 N

X3.7 P
X3.6 157
S
X3.5 VTS 15
X3.4
Low voltage

N
28 M 46
X3.3 1~ ZP 13
L

X3.2
X3.1 6

3
2 145
1 3
145 2
1
3
145 2
1

5
2
N
96 40
L
N
40A 40 36
L
N
A1 M
1~ 46
L
N
A2 M
1~ ZP 13
L 6
2 2
145
1 1

36
5
N
40A 40
L
N
24 M
1~ 33
L
37
STB 12
N
22
L
2
PWM
1
4
6 KOL 31
3
2
5 SOL 11
1
2
5822 470 GB

1 145

ID: 4605029_1001_03

System examples VIESMANN 195


Solar thermal systems (cont.)

6.4 Vitodens / Vitoladens DHW heating with freshwater module and central heating
backup with a heating water buffer cylinder, with solar control module
Entire heating water buffer cylinder rP is heated by the solar thermal
system if the insolation is sufficient for this.
The upper section of heating water buffer cylinder rP will only be
reheated by boiler 1 if the set temperature selected at boiler circuit
control unit 2 is not reached.
The burner is started via cylinder temperature sensor rW of the boiler
circuit control unit, and 3-way diverter valve rZ changes to position
"AB-A". When the set DHW temperature has been reached, the burner
stops and 3-way diverter valve rZ changes to position "AB-B".

ID: 4605030_1001_03 Suppression of reheating of the heating water buffer cylinder by


the boiler in conjunction with solar control module (type SM1)
Reheating suppression takes place in two stages.
Main components Reheating of heating water buffer cylinder rP by boiler 1 is sup-
Viessmann solar collectors pressed, as soon as heating water buffer cylinder rP is heated by col-
Freshwater module lectors eP. For this, the set DHW temperature for reheating is reduced
Heating water buffer cylinder Vitocell140-E or Vitocell 160-E by boiler 1. Suppression remains active for a certain time after solar
Solar control module, type SM1 circuit pump eE has been switched off.
Solar-Divicon In the case of uninterrupted heating by collectors eP (> 2 h) boiler
Wall mounted oil/gas boiler from the year of manufacture 2010 1 will only reheat, if the set cylinder temperature (coding address
Vitodens 200-W, type WB2C "67") selected at boiler circuit control unit 2 is not achieved.
Vitodens 300-W, type WB3D In control unit 2, coding address "67" defaults a third set DHW tem-
Vitoladens 300-W, type VP3C perature (setting range 10 to 95 C). This value must be below the first
set DHW temperature.
Function description Heating water buffer cylinder rP will only be heated by boiler 1, if this
DHW is heated where hot water is being drawn by freshwater mod- set value cannot be achieved by the solar thermal system.
ule qP. Freshwater module qP is supplied with energy from heating
water buffer cylinder rP. Heating water buffer cylinder rP is heated by DHW heating without solar energy
the solar thermal system or its top section is heated by boiler 1. The top section of heating water buffer cylinder rP is heated by boiler
DHW is heated by freshwater module qP according to the instantane- 1.
ous water heater principle. An internal pump delivers the heating water The cylinder thermostat with cylinder temperature sensor rW of boiler
from heating water buffer cylinder rP to freshwater module qP. This circuit control unit 2 switches 3-way diverter valve rZ.
heats the DHW according to the countercurrent principle in the heat
exchanger of freshwater module qP. Control is provided by the internal Central heating with solar energy
control unit of freshwater module qP. If the temperature at sensor rE is sufficient, central heating will be
When using a freshwater module with integral DHW circulation pump, provided by heating water buffer cylinder rP.
for optimum layering of the return water into heating water buffer cyl-
inder rP, 3-way diverter valve qQ in conjunction with sensors S3 qE Central heating without solar energy
and S4 qW of the freshwater module can be controlled by its own con- If the temperature at sensor rE is inadequate, the burner and circula-
trol unit. tion pump in the Vitodens are started. The section between HV3/HR1
and HR2 inside the heating water buffer cylinder rP is heated to the
DHW heating with solar energy set value for the weather-compensated operation of the heating cir-
6 Solar circuit pump eE starts, if the temperature differential between cuits. When this set temperature is exceeded, the burner and, after a
collector temperature sensor eQ and cylinder temperature sensor rQ delay, the circulation pump in the Vitodens are stopped.
exceeds the start temperature differential, and heating water buffer
cylinder rP will be heated.
Solar circuit pump eE stops if:
The actual temperature drops below the stop temperature differen-
tial
The electronic temperature limit (max. at 90 C) set at control unit
eZ is exceeded
The temperature selected at high limit safety cut-out (STB) rR (if
installed) is reached

Codes required on the boiler and heating circuit control unit

Code Function
51:2 The internal circulation pump is only switched on when the burner has been started (time delay off)
(if the coding address
exists)
53:3 Only for Vitodens:
3-way diverter valve rZ is connected to output sK of the internal extension H1 or H2
5b:1 Internal diverter valve without function
5822 470 GB

(DHW cylinder connected downstream of 3-way diverter valve rZ)

196 VIESMANN System examples


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605030_1001_03


--36/6--

--KM-Bus--
Vorlauf

31
30

--6--
--5--
36
Ruecklauf

--24--
--230V--
32

--x/28--
46
A
B
AB

33 ----36/24--

WW

44
--36/24-- 10
42
--2/5--

43
--2/X3-- 1
KW

--36/5--
41 --10/R3--
--10/S3-- B
11 AB A
13
12
--S3--
--S4--

40
--10/S4--
--X3--
--5--

10
--R3--
--230V--

2 3 4
--28--
-230V-

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
6
5822 470 GB

System examples VIESMANN 197


Solar thermal systems (cont.)

Equipment required

ID: 4605030_1001_03
Pos. Description Part no.
1 Wall mounted oil/gas boiler As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
rW Cylinder temperature sensor STS part of the standard delivery of pos.
2
3 Internal extension H1 (standard delivery for the Vitodens 300-W) 7179 057
or
4 Internal extension H2 7179 144
or
for Vitoladens 300-W:
5 Extension AM1 7429 152
qP Freshwater module As per Viessmann pricelist
qQ 3-way diverter valve on-site
qW Temperature sensor S4 Accessories pos. 10
qE Temperature sensor S3 Accessories pos. 10
rP Heating water buffer cylinder As per Viessmann pricelist
rQ Cylinder temperature sensor (SOL) part of the standard delivery of pos.
36
rR High limit safety cut-out STB Z001 889
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump part of the standard delivery of pos.
32
eZ Solar control module, type SM1 7429 073
eU Junction box on-site
eI ON/OFF switch on-site
rE Temperature sensor (flow temperature sensor for low loss header; in this scheme integrated into 7179 488
the heating water buffer cylinder)
rZ 3-way diverter valve 7814 924
For boiler and heating circuit accessories, see boiler scheme

6 5822 470 GB

198 VIESMANN System examples


Solar thermal systems (cont.)

Electrical installation scheme

Wall mounted gas boiler circuit control unit and solar control module

3
2 38
2 L
N
96
40 230 V/ 50 Hz 96 N
L
230 V/ 50 Hz

N
53 L
L
96 96 3 4 1
N
N
28 M
1~ 46
40 5 L

2 L
96
5 STS 42 96 N

X3.7 P
X3.6 157
S
X3.5 VTS 43
X3.4
Low voltage

N
28 M
X3.3 1~ 46
L

X3.2
X3.1 5
2
N
96 40
L
N
40A 40 36
L
N
A1 M
1~ 46
L
N
A2
L

2 2
145
1 1

36
5
N
40A 40
L
N 6
24 M
1~ 33
L
37
STB 44
N
22
L
2
PWM
1
4
6 KOL 31
3
2
5 SOL 41
1
2
1 145

ID: 4605030_1001_03
5822 470 GB

System examples VIESMANN 199


Solar thermal systems (cont.)

Control unit, freshwater module

R5-M
R5-R
R5-A
GND

R4
R3
R2
R1
L N
S1
S2
S3
S4
S5
S6
S7

qP

M
1~
?N L
qE qW qQ 230 V / 50 Hz

ID: 4605030_1001_03

6 5822 470 GB

200 VIESMANN System examples


Solar thermal systems (cont.)

6.5 DHW heating with solar retrofit system, incl. Vitosolic 100
Version A:
The temperature differential between sensor S2 qQ and sensor S3
qU exceeds the start temperature differential, then transfer pump R2
qT starts. The water heated in DHW cylinder 1 qP is transferred to
DHW cylinder 2 qI.
Transfer pump R2 also starts if there is a demand for DHW heating
issued by the auxiliary function.
Transfer pump R2 qT stops if:
The actual temperature drops below the stop temperature differ-
ential
ID: 4605155_1001_01 When the auxiliary function for DHW heating ends
DHW circulation pump qE (if installed) for DHW cylinder 2 qI is
switched via boiler circuit control unit 2.
There are two control versions for this system example:
Version A: Version B:
Transfer with sensor S3 in DHW cylinder 2 (existing) If the temperature at sensor S3 qU exceeds the start temperature,
Differential temperature control then transfer pump R2 qT starts.
Version B: The water heated in DHW cylinder 1 qP is transferred to DHW cyl-
Transfer with sensor S3 in DHW cylinder 1 (retrofit) inder 2 qI.
Control via thermostat function Transfer pump R2 also starts if there is a demand for DHW heating
issued by the auxiliary function.
If it is possible to position the temperature sensor for the DHW circu- Transfer pump R2 qT stops if:
lation transfer in the existing cylinder, we recommend version A. If the actual temperature drops below the stop temperature differ-
ential
Main components When the auxiliary function for DHW heating ends
Viessmann solar collectors DHW circulation pump qE (if installed) for DHW cylinder 2 qI is
Mono-mode DHW cylinder (existing) switched via boiler circuit control unit 2.
Solar retrofit system with the following components:
Solar-Divicon SR Additional function for DHW heating
Vitosolic 100, type SD1 The requirements for the auxiliary function (see "Vitosol" technical
DHW cylinder Vitocell 100-W, type CUG guide) are met by transfer pump R2 qT.
Oil/gas boiler (existing)
Suppression of DHW cylinder reheating by the boiler
Function description Coding address 67 in boiler circuit control unit 2 defaults a third set
DHW temperature (setting range 10 to 95 C). This value must be
DHW heating with solar energy below the first set DHW temperature. DHW cylinder 2 qI will only be
If the temperature differential between collector temperature sen- heated by boiler 1 (solar circuit pump R1 eE runs) if this set value
sor S1 eQ and cylinder temperature sensor S2 qQ exceeds the start cannot be achieved by the solar thermal system.
temperature differential, then solar circuit pump R1 eE starts and DHW
cylinder 1 qP will be heated. DHW heating without solar energy
Solar circuit pump R1 eE stops if: DHW cylinder 2 qI is heated by boiler 1. The cylinder thermostat
Actual temperature dropping below the stop temperature differential with cylinder temperature sensor 3 of boiler circuit control unit 2
DT A regulates cylinder heating.
The electronic temperature limit (max. 90 C) of control unit eZ is
6
exceeded
The temperature selected at high limit safety cut-out (STB) qW (if
installed) is reached
5822 470 GB

System examples VIESMANN 201


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605155_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--
--S3--
30

36
Ruecklauf

--R1--
--R2--
--230V--

32

--2/21--
4
33 ----36/R1--
WW

14 13 --2/28--
--36/R1--
--36/R2--

12 2
A
17
15 -- 1 --36/S3--
--36/S3--
17 B
3
11
--2/5--
--36/S2--

KW 10 18
1
--5--

2
--21--

--28--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
6
A/B For a description of these versions (for temperature sensor S3
qU), see page 201.
5822 470 GB

202 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605155_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit Standard delivery, boiler
3 Cylinder temperature sensor Standard delivery, control unit
4 Circulation pump for cylinder heating As per Viessmann pricelist
qI DHW cylinder 2, mono-mode (existing) on-site
qP DHW cylinder 1, mono-mode (solar retrofit system) Standard delivery, solar retrofit
system
qQ Cylinder temperature sensor S2 (SOL) Standard delivery, solar retrofit
system
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
qT Circulation pump R2 (transfer) As per Vitoset pricelist
qU Temperature sensor S3 Standard delivery, solar retrofit
system
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) Standard delivery, solar retrofit
system
eW Solar-Divicon SR Standard delivery, solar retrofit
system
eE Solar circuit pump R1 Standard delivery, solar retrofit
system
eZ Vitosolic 100, type SD1 (integrated into pos. eW) Standard delivery, solar retrofit
system
eU Junction box on-site
eI ON/OFF switch on-site
For boiler and heating circuit accessories, see boiler scheme

6
5822 470 GB

System examples VIESMANN 203


Solar thermal systems (cont.)

Electrical installation scheme

eZ eI

21
20 230 V / 50 Hz
? 15
230 V / 50 Hz

eU
19
18 M R1 eE
1~
? 14

STB qW

17
16 M R2 qT
1~
? 13

145 12 KM BUS 2
11
10
9
Low voltage

6
qU
5
4
3 SOL qQ

2
KOL eQ
1

ID: 4605155_1001_01

6 5822 470 GB

204 VIESMANN System examples


Solar thermal systems (cont.)

6.6 DHW heating with dual mode DHW cylinder and central heating backup with heating
water buffer cylinder, with Vitosolic 200
DHW heating without solar energy
The upper section of DHW cylinder qP is heated by boiler 1. The
cylinder thermostat with cylinder temperature sensor 3 of boiler cir-
cuit control unit 2 switches the circulation pump for cylinder heat-
ing 4.

Central heating with solar energy


Circulation pump R4 eT starts to heat heating water buffer cylinder
rP if DHW cylinder qP cannot be heated, and the temperature differ-
ential between collector temperature sensor S1 eQ and buffer cylinder
ID: 4605156_1001_01 temperature sensor S4 rQ exceeds temperature differential "T2on".
The pump stops if the actual temperature falls below the temperature
differential "T2off" or it reaches the set buffer cylinder temperature.
Main components The temperature inside heating water buffer cylinder rP will be limited
Viessmann solar collectors by the electronic temperature limiter or high limit safety cut-out rR (if
DHW cylinders Vitocell 100-B or Vitocell 300-B required). This switches circulation pump R4 eT off if the set temper-
Heating water buffer cylinder Vitocell140-E or Vitocell 160-E ature is exceeded.
Vitosolic 200, type SD4 Circulation pump R4 eT is stopped roughly every 15 min for approx.
Solar-Divicon 2 min, (times adjustable), to check whether the temperature at collector
Solar pump line temperature sensor S1 eQ is high enough to change over to DHW
Oil/gas boilers cylinder heating qP.
If the temperature differential between buffer cylinder temperature
Function description sensor S5 rE and heating circuit return sensor S6 rT exceeds tem-
perature differential "T6on", then 3-way diverter valve R6 rZ
DHW heating with solar energy switches to position "AB-A"; the heating return water is then routed via
Solar circuit pump R1 eE starts and DHW cylinder qP is heated up, if heating water buffer cylinder rP into boiler 1. If the temperature of
the temperature differential between collector temperature sensor S1 the preheated return water is too low, boiler 1 reheats the water to
eQ and cylinder temperature sensor S2 qQ exceeds the start temper- the required flow temperature. 3-way diverter valve R6 rZ switches to
ature differential. position "AB-B" if the actual temperature falls below stop temperature
Solar circuit pump R1 eE stops if: differential "T6off".
The actual temperature drops below the stop temperature differen-
tial Central heating without solar energy
The electronic temperature limit (max. at 90 C) set at control unit 3-way diverter valve R6 rZ remains at zero volt (position "AB-B") if the
eZ is exceeded temperature differential between buffer cylinder temperature sensor
The temperature selected at high limit safety cut-out (STB) qW (if S5 rE and heating circuit return temperature sensor S6 rT is less than
installed) is reached temperature differential "T6off". There will be no flow through heating
water buffer cylinder rP.
Additional function for DHW heating Boiler 1 supplies the heating circuits with heat according to the heat-
The requirements for the auxiliary function (see "Vitosol" technical ing curve set at boiler circuit control unit 2.
guide) are met by circulation pump R5 qT.

Suppression of DHW cylinder reheating by the boiler


In boiler circuit control unit 2 coding address 67 defaults a third set 6
DHW temperature (adjustable from 10 to 95 C). This value must be
below the first set DHW temperature. DHW cylinder qP will only be
heated by boiler 1 (solar circuit pump R1 eE runs) if this set value
cannot be achieved by the solar thermal system.
5822 470 GB

System examples VIESMANN 205


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605156_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--

--S4--
--S5--
--S6--
30

36
Ruecklauf

--R1--

--R4--
--R5--
--R6--
--230V--
34 32

35 4
-- 33 ---36/R1-- 45
--36/R4--

WW --36/S6--

AB
B
A
14 13 46

--36/R6--
-36/R1-

12 44
3
--36/R4--
--36/R5--

43
--36/S5--
15 --

41
11 --36/S4--
--36/S2--

KW 10 40
1

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
6 5822 470 GB

206 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605156_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
DHW heating with solar energy
qP Dual mode DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
qT Circulation pump R5 (transfer) As per Vitoset pricelist
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 200, type SD4 Z007 388
eU Junction box on-site
eI ON/OFF switch on-site
Central heating with solar energy
rP Heating water buffer cylinder As per Viessmann pricelist
eR Solar pump line 7188 393 or 7188 394
eT Solar circuit pump for heating buffer cylinder R4 part of the standard delivery of pos.
34
rQ Temperature sensor S4 (heating water buffer cylinder), heating up part of the standard delivery of pos.
36
rE Temperature sensor S5 (heating water buffer cylinder), discharge 7426 247
rR High limit safety cut-out STB Z001 889
rT Return temperature sensor S6 (heating circuit) 7426 247
rZ 3-way diverter valve R6 7814 924
Accessories
uQ Solar cell 7408 877
uW Heat meter extension kit (flow meter) As per Viessmann pricelist
uE Large display 7438 325
uR Datalogger As per Viessmann pricelist
For boiler and heating circuit accessories, see boiler scheme
6
5822 470 GB

System examples VIESMANN 207


Solar thermal systems (cont.)

Electrical installation scheme

38
36
L
N 230 V/ 50 Hz

R1
M
N 1~ 33
37
R2 STB 12
N

R3
230 V/ 50 Hz

R4
M
N 1~ 36
37
STB 44

R5
M
N 1~ 15

R6
M 46
N 1~

S1 KOL 31

S2 SOL 11

S3

S4 41

S5 43

S6 45
.
.
.
Low voltage

S12
CS10 71

Imp 1 72

Imp 2 72

V BUS 73 / 74

145 KM BUS

6
ID: 4605156_1001_01
5822 470 GB

208 VIESMANN System examples


Solar thermal systems (cont.)

6.7 DHW heating with two mono-mode DHW cylinders, with Vitosolic 200
Transfer pump R5/R6 qT starts if:
If the temperature differential between sensor S2 qZ and sensor S6
qU exceeds start temperature differential "T6on"
Additional function for DHW heating is enabled

Note
For the requirements of the auxiliary function, see the "Vitosol" tech-
nical guide.

The water heated in DHW cylinder 1 qP is transferred to DHW cylin-


ID: 4605157_1001_01 der 2 qI. DHW cylinder 2 qI is also heated by solar energy.
Transfer pump R5/R6 qT stops when the actual temperature falls
below stop temperature differential "T6off" or if the additional function
Main components stops.
Viessmann solar collectors DHW circulation pump qE (if installed) for DHW cylinder 2 qI is
2 DHW cylinders Vitocell 100-V or Vitocell 300-V switched via boiler circuit control unit 2.
Vitosolic 200, type SD4
Solar-Divicon Suppression of DHW cylinder reheating by the boiler
Oil/gas boilers Coding address 67 in boiler circuit control unit 2 defaults a third set
DHW temperature (setting range 10 to 95 C). This value must be
Function description below the first set DHW temperature. DHW cylinder 2 qI will only be
heated by boiler 1 (solar circuit pump R1 eE runs) if this set value
DHW heating with solar energy cannot be achieved by the solar thermal system.
If the temperature differential between collector temperature sen-
sor S1 eQ and cylinder temperature sensor S2 qQ exceeds the start DHW heating without solar energy
temperature differential, then solar circuit pump R1 eE starts and DHW DHW cylinder 2 qI is heated by boiler 1. The cylinder thermostat
cylinder 1 qP will be heated. with cylinder temperature sensor 3 of boiler circuit control unit 2
Solar circuit pump R1 eE stops if: switches the circulation pump for cylinder heating 4.
The actual temperature drops below the stop temperature differen-
tial
The electronic temperature limit (max. at 90 C) set at control unit
eZ is exceeded
The temperature selected at high limit safety cut-out (STB) qW (if
installed) is reached

6
5822 470 GB

System examples VIESMANN 209


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605157_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--

--S5--
--S6--
30

36
Ruecklauf

--R1--

--R5--
--R6--
--230V--

32

4
33 ----36/R1--
WW

14 13
-36/R1-

12
--36/R5;R6--

1 2
16 17
15 -- --36/S5-- --36/S6--

11 3
--36/S2--

KW 10 18
1

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

6 5822 470 GB

210 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605157_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
(integrated for wall mounted oil/gas boiler)
qI DHW cylinder 2, mono-mode As per Viessmann pricelist
qP DHW cylinder 1, mono-mode As per Viessmann pricelist
qQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump ZP As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 200, type SD4 Z007 388
DHW circulation diversion
qT Circulation pump R5/R6 (transfer) As per Vitoset pricelist
qZ Temperature sensor S5 (DHW cylinder 1) part of the standard delivery of pos.
36
qU Temperature sensor S6 (DHW cylinder 2) 7426 247
eU Junction box on-site
eI ON/OFF switch on-site
Accessories
uQ Solar cell 7408 877
uW Heat meter extension kit (flow meter) As per Viessmann pricelist
uE Large display 7438 325
uR Datalogger As per Viessmann pricelist
For boiler and heating circuit accessories, see boiler scheme

6
5822 470 GB

System examples VIESMANN 211


Solar thermal systems (cont.)

Electrical installation scheme

38
36
L
N 230 V/ 50 Hz

R1
M
N 1~ 33
37
R2 STB 12
N

R3
230 V/ 50 Hz

R4
N

R5
M
N 1~ 15

R6 A
N

S1 KOL 31

S2 SOL 11

S3

S4

S5 16

S6 17
.
.
.
Low voltage

S12
CS10 71

Imp 1 72

Imp 2 72

V Bus 73 / 74

145 KM BUS

6
ID: 4605157_1001_01

A Insert the jumper between R5 and R6.


5822 470 GB

212 VIESMANN System examples


Solar thermal systems (cont.)

6.8 DHW and swimming pool water heating with dual mode DHW cylinder, with
Vitosolic 200
DHW heating without solar energy
The upper section of DHW cylinder qP is heated by boiler 1. The
cylinder thermostat with cylinder temperature sensor 3 of boiler cir-
cuit control unit 2 switches the circulation pump for cylinder heat-
ing 4.

Swimming pool water heating by solar energy


If DHW cylinder qP cannot continue to be heated, the system checks
whether swimming pool tP can be heated. If the temperature differ-
ential between collector temperature sensor S1 eQ and temperature
ID: 4605158_1001_01 sensor S4 tW exceeds the start temperature differential "T2on", then
transfer pump R4 eT starts. The pump stops if the actual temperature
falls below the stop temperature differential "T2off" or if the set swim-
Main components ming pool temperature has been reached.
Viessmann solar collectors The runtime of circulation pump R4 eT will be interrupted approx.
DHW cylinders Vitocell 100-B or Vitocell 300-B every 30 min for approx. 7 min (times adjustable), to check whether
Swimming pool the temperature at collector temperature sensor S1 eQ is high enough
2 heat exchangers for swimming pool water to change over to heating DHW cylinder qP.
Vitosolic 200, type SD4 If the temperature differential between temperature sensor S3 tT and
Solar-Divicon temperature sensor S4 tW exceeds start temperature differential
Solar pump line "T5on" and start temperature differential "Th2on" has not been
Oil/gas boilers reached, then circulation pump for swimming pool heating R3 tE
starts. The pump stops if the actual temperature falls below the stop
Function description temperature differential "Toff" or if the stop temperature "Th2off" has
been reached.
DHW heating with solar energy Swimming pool water heating by boiler:
Solar circuit pump R1 eE starts and DHW cylinder qP is heated up, if If the solar energy is inadequate to heat the swimming pool water, it
the temperature differential between collector temperature sensor S1 will be heated by boiler 1 via temperature sensor S5 tU on heat
eQ and cylinder temperature sensor S2 qQ exceeds the start temper- exchanger 2 tZ.
ature differential. Circulation pump zP and filter pump tI start if the actual temperature
Solar circuit pump R1 eE stops if: falls below start temperature "Th3on". The pumps stop when the stop
The actual temperature drops below the stop temperature differen- temperature"Th3off" has been reached or if the time frame is excee-
tial ded.
The electronic temperature limit (max. at 90 C) set at control unit Filter time and any reheating by boiler 1 should fall outside the times
eZ is exceeded during which heating by solar energy can be expected. The start and
The temperature selected at high limit safety cut-out (STB) qW (if stop times can be adjusted via time switch 2 of the Vitosolic 200 (type
installed) is reached SD4).

Additional function for DHW heating


The requirements for the auxiliary function (see "Vitosol" technical
guide) are met by circulation pump R5 qT.

Suppression of DHW cylinder reheating by the boiler 6


In boiler circuit control unit 2 coding address 67 defaults a third set
DHW temperature (adjustable from 10 to 95 C). This value must be
below the first set DHW temperature. DHW cylinder qP will only be
heated by boiler 1 (solar circuit pump R1 eE runs) if this set value
cannot be achieved by the solar thermal system.
5822 470 GB

System examples VIESMANN 213


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605158_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--
--S3--
--S4--
--S5--
30

36
Ruecklauf

--R1--

--R3--
--R4--
--R5--
--R6--
--230V--
34 32

35
--- 33 ---36/R1--
--36/R4--

WW
60

56

14 13
--36/S5-- 59
4
57
-36/R1-

12 58
3
--36/R5--

15 --

--36/S3--
11 54 55
--36/S2--

10 53 51
50
--36/S4--
KW 1 52

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
6 5822 470 GB

214 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605158_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
qP Dual mode DHW cylinder As per Viessmann pricelist
qQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump ZP As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
qT Circulation pump R5 (transfer) As per Vitoset pricelist
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 200, type SD4 Z007 388
eU Junction box on-site
eI ON/OFF switch on-site
Swimming pool water heating by solar energy
tP Swimming pool on-site
tQ Heat exchanger 1 As per Viessmann pricelist
tW Temperature sensor S4 (swimming pool) part of the standard delivery of pos.
36
tT Temperature sensor S3 (heat exchanger 1) 7426 247
eR Solar pump line 7188 393 or 7188 394
eT Solar circuit pump for swimming pool water heating R4 part of the standard delivery of pos.
34
tE Circulation pump for swimming pool heating R3 on-site
tR Temperature limiter (maximum limit) Z001 887
eI Contactor relay 7814 681
Swimming pool water heating by oil/gas boiler
tZ Heat exchanger 2 As per Viessmann pricelist
tU Temperature sensor S5 (heat exchanger 2) 7426 247
tO Temperature limiter (maximum limit) Z001 887
zP Circulation pump for swimming pool water heating R6 (reheating) on-site
zQ Control module V 7143 513
(in conjunction with Vitotronic 200, type KW1, KW2, KW4, KW5 and Vitotronic 300, type KW3 for
boilers with two-stage or modulating burners)
6
tI Filter pump on-site
eO Contactor relay 7814 681
Accessories
uQ Solar cell 7408 877
uW Heat meter extension kit (flow meter) As per Viessmann pricelist
uE Large display 7438 325
uR Datalogger As per Viessmann pricelist
For boiler and heating circuit accessories, see boiler scheme
5822 470 GB

System examples VIESMANN 215


Solar thermal systems (cont.)

Electrical installation scheme

eI

eZ 230 V / 50 Hz

L 35
N
?
M eE
R134 1~
R233
230 V / 50 Hz

qW
R332
R431 M
1~ eT
R530
N
? tR
R629
R7-R
R7-M M eO
1~ qT
R7-A
2
S1 KOL eQ M tE
2 1~
S2 SOL qQ
2 tO
S3 tT
2
S4 tW
2
S5 tU
Low voltage

S6
. eO
.
. 2
CS10 uQ
2
Imp 1 uW M
2 1~ zP
Imp 2 uW
2 AB
V BUS uE/uR
2
145 KM BUS eU

ID: 4605158_1001_01

6 A, B See below.

A Start signal for filter pump tI (Set the minimum set boiler water temperature via coding address
B External burner start in conjunction with the following control units: "32" at the boiler circuit control unit)
Vitotronic 200, type KW1, KW2, KW4, KW5, Vitotronic 300, Vitotronic 200, type GW1, GW2:
type KW3: Connection in plug aVH at terminals "2" and "3"
Connection in plug "X12" (Set the minimum set boiler water temperature via coding address
or "9b" at the boiler circuit control unit)
Connection in plug aB at terminals "ON", "ON/TR" Vitotronic 200, type KW6:
or Connection in plug aVD at terminals "1" and "2"
in socket "DE4" in control module V zQ in plug a-D at terminals "1" (Set the minimum set boiler water temperature via coding address
and "2" "9b" at the boiler circuit control unit)
5822 470 GB

216 VIESMANN System examples


Solar thermal systems (cont.)

6.9 DHW heating and central heating backup with a multi-mode heating water buffer cyl-
inder, with Vitosolic 200
If the solar energy is inadequate to cover the entire heating demand,
the DHW in the lower section of heating water buffer cylinder qP will
be preheated by solar energy. The DHW in the upper part of the cyl-
inder is heated to the required temperature by boiler 1.

Suppression of DHW cylinder reheating by the boiler


In boiler circuit control unit 2 coding address 67 defaults a third set
DHW temperature (adjustable from 10 to 95 C). This value must be
below the first set DHW temperature. The DHW cylinder will only be
heated by the boiler (solar circuit pump runs) if this set value cannot
be achieved by the solar thermal system.
ID: 4605159_1001_01
DHW heating without solar energy
Main components The upper area of heating water buffer cylinder qP is heated by boiler
Viessmann solar collectors 1. The integral instantaneous water heater/standby section is heated
Vitocell 340-M or Vitocell 360-M multi-mode heating water buffer by the surrounding buffer cylinder water.
cylinder with integral DHW heating, with or without transfer system The cylinder thermostat with cylinder temperature sensor 3 of boiler
Vitosolic 200, type SD4 circuit control unit 2 switches the circulation pump for cylinder heat-
Solar-Divicon ing 4.
Oil/gas boilers
Central heating with solar energy
Function description 3-way diverter valve R6 rZ switches to position "AB-A" if the temper-
ature differential between buffer cylinder temperature sensor S5 qZ
DHW heating with solar energy and heating circuit return temperature sensor S6 rT exceeds start
Solar circuit pump R1 eE starts, if the temperature differential between temperature differential "T6on". The heating return water is routed
collector temperature sensor S1 eQ and cylinder temperature sensor via heating water buffer cylinder qP to boiler 1.
S2 qQ exceeds the start temperature differential, and heating water If the temperature of the preheated return water is too low, boiler 1
buffer cylinder qP will be heated. reheats the water to the required flow temperature. If the actual tem-
Solar circuit pump R1 eE stops if: perature falls below stop temperature differential "T6off", the 3-way
The actual temperature drops below the stop temperature differen- diverter valve R6 rZ switches to position "AB-B".
tial
The electronic temperature limit (max. at 90 C) set at control unit Central heating without solar energy
eZ is exceeded 3-way diverter valve R6 rZ remains at zero volt (position "AB-B") if the
The temperature selected at high limit safety cut-out (STB) qW (if temperature differential between buffer cylinder temperature sensor
installed) is reached S5 qZ and heating circuit return temperature sensor S6 rT is less than
If the insolation is sufficient, then the entire heating water buffer cylin- temperature differential "T6off". There will be no flow through heating
der qP will be heated by the solar thermal system. water buffer cylinder qP.
The upper section of heating water buffer cylinder qP will only be Boiler 1 supplies the heating circuits with heat according to the heat-
reheated by boiler 1 if the set temperature selected at boiler circuit ing curve set at boiler circuit control unit 2.
control unit 2 is not reached.

6
5822 470 GB

System examples VIESMANN 217


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605159_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--

--S5--
--S6--
30

36
Ruecklauf

--R1--

--R6--
--230V--
32

33 ----36/R1-- 45
WW --36/S6--

13 AB
14 B
A
46

--36/R6--
3 HV1
WW/Z
12 4
SPR1 22
--36/R1--
HV2/HR1
16 SPR2
--36/S5-- HR2
11 SPR3 HR3
--36/S2--
KW
E
HVs/HRs

KW 10
1

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

6 5822 470 GB

218 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605159_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
5 Flow temperature sensor for low loss header 7179 488
6 Low loss header As per Vitoset pricelist
qP Multi-mode heating water buffer cylinder As per Viessmann pricelist
with
wW Threaded DHW circulation fitting 7198 542
DHW heating with solar energy
qQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump ZP As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 200, type SD4 Z007 388
eU Junction box on-site
eI ON/OFF switch on-site
Central heating with solar energy
qZ Temperature sensor S5 (heating water buffer cylinder) part of the standard delivery of pos.
36
rT Return temperature sensor S6 (heating circuit) 7426 247
rZ 3-way diverter valve R6 7814 924
Accessories
uQ Solar cell 7408 877
uW Heat meter extension kit (flow meter) As per Viessmann pricelist
uE Large display 7438 325
uR Datalogger As per Viessmann pricelist
For boiler and heating circuit accessories, see boiler scheme

6
5822 470 GB

System examples VIESMANN 219


Solar thermal systems (cont.)

Electrical installation scheme

38
36
L
N 230 V/ 50 Hz

R1
M
N 1~ 33
37
R2 STB 12
N

R3
230 V/ 50 Hz

R4
N

R5
N

R6
M 46
N 1~

S1 KOL 31

S2 SOL 11

S3

S4

S5 16

S6 45
.
.
.
Low voltage

S12
CS10 71

Imp 1 72

Imp 2

V Bus 73 / 74

145 KM BUS

6
ID: 4605159_1001_01
5822 470 GB

220 VIESMANN System examples


Solar thermal systems (cont.)

6.10 DHW heating and central heating backup with a multi-mode heating water buffer cyl-
inder, with solar control module
In control unit 2, coding address "67" defaults a third set DHW tem-
perature (setting range 10 to 95 C). This value must be below the first
set DHW temperature.
Heating water buffer cylinder qP will only be heated by boiler 1, if this
set value cannot be achieved by the solar thermal system.

Suppression of reheating by the boiler in the case of central heat-


ing backup
If the temperature inside heating water buffer cylinder qP is adequate
for heating the heating circuit, reheating by boiler 1 can be sup-
ID: 4605160_1001_01 pressed.

DHW heating without solar energy


Main components The upper area of heating water buffer cylinder qP is heated by boiler
Viessmann solar collectors 1. The integral instantaneous water heater/standby section is heated
Vitocell 340-M or Vitocell 360-M multi-mode heating water buffer by the surrounding buffer cylinder water.
cylinder with integral DHW heating, with or without transfer system The cylinder thermostat with cylinder temperature sensor 3 of boiler
Solar control module, type SM1 circuit control unit 2 switches the circulation pump for cylinder heat-
Solar-Divicon ing 4.
Wall mounted oil/gas boiler
Central heating with solar energy
Function description 3-way diverter valve rZ switches to position "AB-A" if the temperature
differential between buffer cylinder temperature sensor qZ and heating
DHW heating with solar energy circuit return temperature sensor rT exceeds the start temperature
Solar circuit pump eE starts, if the temperature differential between differential. The heating return water is routed via heating water buffer
collector temperature sensor eQ and cylinder temperature sensor qQ cylinder qP to boiler 1.
exceeds the start temperature differential, and heating water buffer If the temperature of the preheated return water is too low, boiler 1
cylinder qP will be heated. reheats the water to the required flow temperature. If the actual tem-
Solar circuit pump eE stops if: perature falls below the stop temperature differential, then 3-way
The actual temperature drops below the stop temperature differen- diverter valve rZ changes to position "AB-B".
tial
The electronic temperature limit (max. at 90 C) set at control unit Central heating without solar energy
eZ is exceeded 3-way diverter valve rZ remains at zero volt (position "AB-B") if the
The temperature selected at high limit safety cut-out (STB) qW (if temperature differential between buffer cylinder temperature sensor
installed) is reached qZ and heating circuit return temperature sensor rT is less than the
If the insolation is sufficient, then the entire heating water buffer cylin- stop temperature differential. There will be no flow through heating
der qP will be heated by the solar thermal system. water buffer cylinder qP.
The upper section of heating water buffer cylinder qP will only be Boiler 1 supplies the heating circuits with heat according to the heat-
reheated by boiler 1 if the set temperature selected at boiler circuit ing curve set at boiler circuit control unit 2.
control unit 2 is not reached.
If the solar energy is inadequate to cover the entire heating demand, In conjunction with a wall mounted oil/gas boiler
the DHW in the lower section of heating water buffer cylinder qP will A low loss header 6 with flow temperature sensor 5 is required.
be preheated by solar energy. The DHW in the upper part of the cyl- 6
inder is heated to the required temperature by boiler 1. Codes required on the boiler and heating circuit control unit
Code Function
Suppression of reheating of the heating water buffer cylinder by 53:3 System without DHW circulation pump:
the boiler in conjunction with solar control module (type SM1) Circulation pump for cylinder heating 4 is con-
Reheating suppression takes place in two stages. nected to output sK of the internal extension H1
Reheating of heating water buffer cylinder qP by boiler 1 is sup- or H2
pressed, as soon as heating water buffer cylinder qP is heated by col- 5b:1 Internal diverter valve without function
lectors eP. For this, the set DHW temperature for reheating is reduced (DHW cylinder connected downstream of the low
by boiler 1. Suppression remains active for a certain time after solar loss header)
circuit pump eE has been switched off.
In the case of uninterrupted heating by collectors eP (> 2 h) boiler
1 will only reheat, if the set cylinder temperature (coding address
"67") selected at boiler circuit control unit 2 is not achieved.
5822 470 GB

System examples VIESMANN 221


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605160_1001_01


--36/6--

--KM-Bus--
Vorlauf

31

--10--
30

--6--
--5--

--7--
36
Ruecklauf

--24--

--22--
--230V--
32

33 ----36/24-- 45
WW --36/10--

13 AB
14 B
A
46

--36/22--
3 HV1
WW/Z
12 SPR1 4
22
--36/24--
HV2/HR1
16 SPR2
--36/7-- HR2 5
11 SPR3
HR3
--36/5--
KW 1
E
HVs/HRs

KW 10 6

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.

6 5822 470 GB

222 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605160_1001_01
Pos. Description Part no.
1 Wall mounted oil/gas boiler As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
(appropriate extensions may be required for the connection of wall mounted oil/gas boilers)
5 Flow temperature sensor for low loss header 7179 488
6 Low loss header As per Vitoset pricelist
qP Multi-mode heating water buffer cylinder As per Viessmann pricelist
with
wW Threaded DHW circulation fitting 7198 542
DHW heating with solar energy
qQ Cylinder temperature sensor (SOL) part of the standard delivery of pos.
36
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump ZP As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
qZ Cylinder temperature sensor STS 7179 114
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump part of the standard delivery of pos.
32
eZ Solar control module, type SM1 7429 073
eU Junction box on-site
eI ON/OFF switch on-site
Central heating with solar energy
qZ Temperature sensor (heating water buffer cylinder) 7438 702
rT Return temperature sensor (heating circuit) 7438 702
rZ 3-way diverter valve 7814 924
For boiler and heating circuit accessories, see boiler scheme

Electrical installation scheme, solar control module, type SM1

38
36
L
40 230 V/ 50 Hz
N
N
M
6
24 1~ 33
230 V/ 50 Hz

L
37
STB 12

N
22 M 46
1~
L

2
PWM
1

4
10 45
3
2
7 1 STS 16
Low voltage

4
6 KOL 31
3
2
5 SOL 11
1
. 2
145 1 KM BUS
5822 470 GB

ID: 4605160_1001_01

System examples VIESMANN 223


Solar thermal systems (cont.)

6.11 DHW heating with freshwater module and central heating backup with heating water
buffer cylinder, with Vitosolic 200
Solar circuit pump R1 eE stops if:
The actual temperature drops below the stop temperature differen-
tial
The electronic temperature limit (max. at 90 C) set at control unit
eZ is exceeded
If the temperature set at high limit safety cut-out rR (if installed) is
reached
Entire heating water buffer cylinder rP is heated by the solar thermal
system if the insolation is sufficient for this.
The upper section of heating water buffer cylinder rP will only be
ID: 4605161_1001_01 reheated by boiler 1 if the set temperature selected at boiler circuit
control unit 2 is not reached.

Main components DHW heating without solar energy


Viessmann solar collectors The top section of heating water buffer cylinder rP is heated by boiler
Freshwater module 1. The cylinder thermostat with cylinder temperature sensor 3 of
Heating water buffer cylinder Vitocell140-E or Vitocell 160-E boiler circuit control unit 2 switches the circulation pump for cylinder
Vitosolic 200, type SD4 heating 4.
Solar-Divicon
Oil/gas boilers Central heating with solar energy
If the temperature differential between buffer cylinder temperature
Function description sensor S5 rW and heating circuit return temperature sensor S6 rT
DHW is heated when hot water is being drawn by freshwater mod- exceeds start temperature differential "T6on", 3-way diverter valve
ule qP. Freshwater module qP is supplied with energy from heating R6 rZ switches to position "AB-A" and the heating return water is
water buffer cylinder rP. Heating water buffer cylinder rP is heated by routed via heating water buffer cylinder rP to boiler 1. If the temper-
the solar thermal system or its top section is heated by boiler 1. ature of the preheated return water is too low, boiler 1 reheats the
DHW is heated by freshwater module qP according to the instantane- water to the required flow temperature. 3-way diverter valve R6 rZ
ous water heater principle. An internal pump delivers the heating water switches to position "AB-B" if the actual temperature falls below stop
from heating water buffer cylinder rP to freshwater module qP. This temperature differential "T6off".
heats the DHW according to the countercurrent principle in the heat
exchanger of freshwater module qP. Control is provided by the internal Central heating without solar energy
control unit of freshwater module qP. 3-way diverter valve R6 rZ remains at zero volt (position "AB-B") if the
When using a freshwater module with integral DHW circulation pump, temperature differential between buffer cylinder temperature sensor
for optimum layering of the return water into heating water buffer cyl- S5 rW and heating circuit return temperature sensor S6 rT is less than
inder rP, 3-way diverter valve qQ in conjunction with sensors S3 qE temperature differential "T6off". Heating water buffer cylinder rP will
and S4 qW of the freshwater module can be controlled by its own con- not receive any flow.
trol unit. Boiler 1 supplies the heating circuit with heat according to the heating
curve set at boiler circuit control unit 2.
DHW heating with solar energy
Solar circuit pump R1 eE starts, if the temperature differential between
collector temperature sensor S1 eQ and cylinder temperature sensor
S2 rQ exceeds the start temperature differential, and heating water
6 buffer cylinder rP will be heated. 5822 470 GB

224 VIESMANN System examples


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605161_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--

--S5--
--S6--
30

36
Ruecklauf

--R1--

--R6--
--230V--
32

--36/S6--
33 ----36/R1--
45

4
AB
B
A
46

--36/R6--
44 10 WW
--36/R1--

42
--36/S5--
--36/S2--
41 --10/R3--
--10/S3-- B
KW

11 AB A
13
--S3--
--S4--

40
1
12 -10/S4-
10
2
--R3--
--230V--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
6
5822 470 GB

System examples VIESMANN 225


Solar thermal systems (cont.)

Equipment required

ID: 4605161_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
qP Freshwater module As per Viessmann pricelist
qQ 3-way diverter valve on-site
qW Temperature sensor S4 Accessories pos. 10
qE Temperature sensor S3 Accessories pos. 10
rP Heating water buffer cylinder As per Viessmann pricelist
DHW heating with solar energy
rQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
rR High limit safety cut-out STB Z001 889
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 200, type SD4 Z007 388
eU Junction box on-site
eI ON/OFF switch on-site
Central heating with solar energy
rW Temperature sensor S5 (heating water buffer cylinder) part of the standard delivery of pos.
36
rT Return temperature sensor S6 (heating circuit) 7426 247
rZ 3-way diverter valve R6 7814 924
Accessories
uQ Solar cell 7408 877
uW Heat meter extension kit (flow meter) As per Viessmann pricelist
uE Large display 7438 325
uR Datalogger As per Viessmann pricelist
For boiler and heating circuit accessories, see boiler scheme

6 5822 470 GB

226 VIESMANN System examples


Solar thermal systems (cont.)

Electrical installation scheme

Vitosolic 200

38
36
L
N 230 V/ 50 Hz

R1
M
N 1~ 33
37
R2 STB 44
N

R3
230 V/ 50 Hz

R4
N

R5
N

R6
M 46
N 1~

S1 KOL 31

S2 SOL 41

S3

S4

S5 42

S6 45
.
.
.
Low voltage

S12
CS10 71

Imp 1 72

Imp 2 72

V BUS 73 / 74

145
6
KM BUS

ID: 4605161_1001_01
5822 470 GB

System examples VIESMANN 227


Solar thermal systems (cont.)

Control unit, freshwater module

R5-M
R5-R
R5-A
GND

R4
R3
R2
R1
L N
S1
S2
S3
S4
S5
S6
S7

qP

M
1~
?N L
qE qW qQ 230 V / 50 Hz

ID: 4605161_1001_01

6 5822 470 GB

228 VIESMANN System examples


Solar thermal systems (cont.)

6.12 DHW heating with mono-mode DHW cylinder and central heating backup with multi-
mode heating water buffer cylinder, with Vitosolic 200
If the insolation is sufficient, then the entire heating water buffer cylin-
der rP will be heated by the solar thermal system.
If the solar energy is insufficient, DHW in the bottom section of heating
water buffer cylinder rP is preheated with solar energy and raised to
the required temperature in DHW cylinder qP by boiler 1.
A temperature-controlled DHW transfer is not possible.

DHW heating without solar energy


DHW cylinder qP is heated by boiler 1. The cylinder thermostat with
cylinder temperature sensor 3 of boiler circuit control unit 2
ID: 4605162_1001_01 switches the circulation pump for cylinder heating 4.

Central heating with solar energy


Main components If the temperature differential between buffer cylinder temperature
Viessmann solar collectors sensor S5 rW and heating circuit return temperature sensor S6 rT
DHW cylinder Vitocell 100-V or Vitocell 300-V exceeds start temperature differential "T6on", 3-way diverter valve
Vitocell 340-M or Vitocell 360-M multi-mode heating water buffer R6 rZ switches to position "AB-A" and the heating return water is
cylinder with integral DHW heating, with or without transfer system routed via heating water buffer cylinder rP to boiler 1. If the temper-
Vitosolic 200, type SD4 ature of the preheated return water is too low, boiler 1 reheats the
Solar-Divicon water to the required flow temperature. 3-way diverter valve R6 rZ
Oil/gas boilers switches to position "AB-B" if the actual temperature falls below stop
temperature differential "T6off".
Function description
Central heating without solar energy
DHW heating with solar energy If the temperature differential between buffer cylinder temperature
Solar circuit pump R1 eE starts, if the temperature differential between sensor S5 rW and heating circuit return temperature sensor S6 rT is
collector temperature sensor S1 eQ and cylinder temperature sensor less than stop temperature differential "T6off", then 3-way diverter
S2 rQ exceeds the start temperature differential, and heating water valve R6 rZ remains at zero volt ( position "AB-B"). There will be no
buffer cylinder rP will be heated. flow through heating water buffer cylinder rP.
Solar circuit pump R1 eE stops if: Boiler 1 supplies the heating circuit with heat according to the heating
The actual temperature drops below the stop temperature differen- curve set at boiler circuit control unit 2.
tial
The electronic temperature limit (max. at 90 C) set at control unit
eZ is exceeded
If the temperature set at high limit safety cut-out rR (if installed) is
reached

6
5822 470 GB

System examples VIESMANN 229


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605162_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--

--S5--
--S6--
30

36
Ruecklauf

--R1--

--R6--
--230V--
32

--36/S6--
4
33 ----36/R1--
WW 45

13 AB
14 B
A
46

--36/R6--
HV1
WW/Z
44 SPR1 43
--36/R1--
HV2/HR1
42 SPR2 3
--36/S5-- HR2
41 SPR3
HR3
--36/S2--
KW
E
HVs/HRs

KW 40 10
1

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
6 5822 470 GB

230 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605162_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
qP DHW cylinder As per Viessmann pricelist
rP Heating water buffer cylinder As per Viessmann pricelist
with
rE Threaded DHW circulation fitting 7198 542
DHW heating with solar energy
rQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
rR High limit safety cut-out STB Z001 889
qE DHW circulation pump ZP As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 200, type SD4 Z007 388
eU Junction box on-site
eI ON/OFF switch on-site
Central heating with solar energy
rW Temperature sensor S5 (heating water buffer cylinder) part of the standard delivery of pos.
36
rT Return temperature sensor S6 (heating circuit) 7426 247
rZ 3-way diverter valve R6 7814 924
Accessories
uQ Solar cell 7408 877
uW Heat meter extension kit (flow meter) As per Viessmann pricelist
uE Large display 7438 325
uR Datalogger As per Viessmann pricelist
For boiler and heating circuit accessories, see boiler scheme

6
5822 470 GB

System examples VIESMANN 231


Solar thermal systems (cont.)

Electrical installation scheme

38
36
L
N 230 V/ 50 Hz

R1
M
N 1~ 33
37
R2 STB 44
N

R3
230 V/ 50 Hz

R4
N

R5
N

R6
M 46
N 1~

S1 KOL 31

S2 SOL 41

S3

S4

S5 42

S6 45
.
.
.
Low voltage

S12
CS10 71

Imp 1 72

Imp 2 72

V BUS 73 / 74

145 KM BUS

6
ID: 4605162_1001_01
5822 470 GB

232 VIESMANN System examples


Solar thermal systems (cont.)

6.13 Large solar thermal systems for DHW heating, with Vitosolic 200
Solar circuit pump R1 eE stops if:
The actual temperature drops below the stop temperature differen-
tial
The electronic temperature limit (max. at 90 C) set at control unit
eZ is exceeded
The temperature selected at high limit safety cut-out (STB) rE (if
installed) is reached
Primary pump (preheat cylinder) R6 qR and discharge pump (heating
water buffer cylinder) R3 qI start if:
The temperature differential between buffer temperature sensor S5
ID: 4605163_1001_01 rW and preheat cylinder temperature sensor S6 qW exceeds start
temperature differential "T6on"
and
Applications temperature in preheat cylinder qQ is below the value set at ther-
Heating system with solar DHW heating and a daily DHW demand of mostatically controlled mixing valve qO
up to approx. 2000 litres (temperature 60 C).
At a daily DHW demand (60 C) above 2000 litres, provide a heating Discharge circuit
system with a separate heating and discharge set. Preheat cylinder qQ is force-filled with cold water. The water in preheat
cylinder qQ is heated via heat exchanger qU.
Main components
Viessmann solar collectors Additional function for DHW heating
DHW cylinder Vitocell 100-V or Vitocell 300-V The requirements for the auxiliary function (see "Vitosol" technical
Vitocell 100-L preheat cylinder guide) are met by circulation pump R5 qT. Cylinders qP and qQ are
Heating water buffer cylinder Vitocell140-E or Vitocell 160-E heated.
Vitosolic 200, type SD4
Solar-Divicon DHW heating without solar energy
Oil/gas boilers DHW cylinder qP is heated by boiler 1. The cylinder thermostat with
cylinder temperature sensor 3 of boiler circuit control unit 2
Function description switches the circulation pump for cylinder heating 4. DHW circulation
pump qE (if installed) is controlled by boiler circuit control unit 2. Pri-
DHW heating with solar energy mary pump (preheat cylinder) R6 qR and discharge pump (heating
water buffer cylinder) R6 qI are shut off. The DHW is routed via pre-
Charge circuit heat cylinder qQ to DHW cylinder qP.
If the temperature differential between collector temperature sen-
sor S1 eQ and cylinder temperature sensor S2 rQ exceeds the start
temperature differential, then solar circuit pump R1 eE starts, and
heating water buffer cylinder rP will be heated.

6
5822 470 GB

System examples VIESMANN 233


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605163_1001_01

40
--36/R1--

--36/S5--

--36/S2--
43

42

41

2
1
4

10
17

19
18

16
--36/R3--

--36/R6--

--R6--
--R5--
14

--S6--
16

--S5--
36

WW

--36/S6--

--R3--
--S2--
6
--R1--
12

--S1--
--230V--
13

--KM-Bus--
11
30

Ruecklauf

----36/R1--

--36/R5--
--

KW
15
Vorlauf

32

33
31

--36/S1--

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
5822 470 GB

234 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605163_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
qP DHW cylinder As per Viessmann pricelist
DHW heating with solar energy
qQ Preheat cylinder As per Viessmann pricelist
qW Temperature sensor S6 (preheat cylinder) 7426 247
qE DHW circulation pump ZP As per Vitoset pricelist
qR Primary pump R6 (preheat cylinder) As per Vitoset pricelist
qT Circulation pump R5 (transfer) As per Vitoset pricelist
qZ Line regulating valve on-site
qU Heat exchanger As per Viessmann pricelist
qI Discharge pump R6 (heating water buffer cylinder) As per Vitoset pricelist
qO Thermostatic mixing valve for hard water protection on-site
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 200, type SD4 Z007 388
eU Junction box on-site
eI ON/OFF switch on-site
rP Heating water buffer cylinder As per Viessmann pricelist
rQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
rW Temperature sensor S5 (heating water buffer cylinder) part of the standard delivery of pos.
36
rE High limit safety cut-out STB Z001 889
Accessories
uQ Solar cell 7408 877
uW Heat meter extension kit (flow meter) As per Viessmann pricelist
uE Large display 7438 325
uR Datalogger As per Viessmann pricelist
For boiler and heating circuit accessories, see boiler scheme

6
5822 470 GB

System examples VIESMANN 235


Solar thermal systems (cont.)

Electrical installation scheme

38
36
L
N 230 V/ 50 Hz

R1
M
N 1~ 33
37
R2 STB 43
N

R3
M
230 V/ 50 Hz

N 1~ 18

R4
N

R5
N M 15
1~

R6
M 14
N 1~

S1 KOL 31

S2 SOL 41

S3

S4

S5 42

S6 12
.
.
.
Low voltage

S12
CS10 71

Imp 1 72

Imp 2 72

V BUS 73 / 74

145 KM BUS

6
ID: 4605163_1001_01
5822 470 GB

236 VIESMANN System examples


Solar thermal systems (cont.)

6.14 Large solar thermal systems for DHW heating with two mono-mode DHW cylinders
and central heating backup with heating water buffer cylinder, with Vitosolic 200
DHW circulation pump qE (if installed) for DHW cylinder 2 qI is
switched via boiler circuit control unit 2.

Additional function for DHW heating


The requirements for the auxiliary function (see "Vitosol" technical
guide) are met by circulation pump R5 qT.

DHW heating without solar energy


DHW cylinder 2 qI will only be heated by boiler 1. The cylinder
thermostat with cylinder temperature sensor 3 of boiler circuit control
ID: 4605164_1001_01 unit 2 switches the circulation pump for cylinder heating 4.

Central heating with solar energy


Applications If DHW cylinder 1 qP cannot be heated, and the temperature differ-
Heating system with solar DHW heating and a daily DHW demand of ential between collector temperature sensor S1 eQ and buffer cylinder
up to approx. 2000 litres (temperature 60 C). temperature sensor S4 rQ exceeds start temperature differential
At a daily DHW demand (60 C) above 2000 litres, provide a heating "T2on", then circulation pump R4 eT starts, in order to heat heating
system with a separate heating and discharge set. water buffer cylinder rP. The pump stops if the actual temperature falls
below the stop temperature differential "T2off" or it reaches the set
Main components buffer cylinder temperature.
Viessmann solar collectors The temperature inside heating water buffer cylinder rP will be limited
DHW cylinder Vitocell 100-V or Vitocell 300-V by the electronic temperature limiter or high limit safety cut-out rR (if
Heating water buffer cylinder Vitocell 140-E required).
Vitosolic 200, type SD4 Circulation pump R4 eT is stopped roughly every 15 min for approx.
Solar-Divicon 2 min, (times adjustable), to check whether the temperature at collector
Solar pump line temperature sensor S1 eQ is high enough to change over to DHW
Oil/gas boilers cylinder heating qP.
If the temperature differential between buffer cylinder temperature
Function description sensor S5 rE and heating circuit return sensor S6 rT exceeds start
temperature differential "T6on", then 3-way diverter valve R6 rZ
DHW heating with solar energy switches to position "AB-A"; the heating return water is then routed via
If the temperature differential between collector temperature sensor heating water buffer cylinder rP into boiler 1. If the temperature of
S1 eQ and cylinder temperature sensor S2 qQ exceeds the start tem- the preheated return water is too low, boiler 1 reheats the water to
perature differential, then solar circuit pump R1 eE starts and DHW the required flow temperature. 3-way diverter valve R6 rZ switches to
cylinder qP will be heated. position "AB-B" if the actual temperature falls below stop temperature
Solar circuit pump R1 eE stops if: differential "T6off".
The actual temperature drops below the stop temperature differen-
tial Central heating without solar energy
The electronic temperature limit (max. at 90 C) set at control unit 3-way diverter valve R6 rZ remains at zero volt (position "AB-B") if the
eZ is exceeded temperature differential between buffer cylinder temperature sensor
The temperature selected at high limit safety cut-out (STB) qW (if S5 rE and heating circuit return temperature sensor S6 rT is less than
installed) is reached temperature differential "T6off". There will be no flow through heating
Transfer pump R5/R7 qT starts if: water buffer cylinder rP. 6
The temperature differential between sensor S7 qZ and sensor S8 Boiler 1 supplies the heating circuit with heat according to the heating
qU exceeds start temperature differential "T7on" curve set at boiler circuit control unit 2.
Additional function for DHW heating is enabled
The water heated in DHW cylinder 1 qP is transferred to DHW cylin-
der 2 qI. DHW cylinder 2 qI is also heated by solar energy.
Transfer pump R5/R7 qT stops when the actual temperature falls
below stop temperature differential "T7off" or if the additional function
stops.
5822 470 GB

System examples VIESMANN 237


Solar thermal systems (cont.)

Hydraulic installation scheme ID: 4605164_1001_01


--36/S1--

--KM-Bus--
Vorlauf

31

--S1--
--S2--
--S4--
--S5--
--S6--
--S7--
--S8--
30

36
Ruecklauf

--R1--

--R4--

--R6--
--R7--
--R5--
--230V--
34 32

35 4
-- 33 ----36/R1-- 45
--36/R4--

WW --36/S6--

AB
B
A
14 13 46

--36/R6--
-36/R1-

44
12
--36/R4--
--36/R7--

1 2 43
--36/S5--
16 17
15 -- --36/S7-- --36/S8--
41
11 3 --36/S4--
--36/S2--

KW 10 18 40
1

Note: This scheme is a basic example without shut-off valves or safety equipment. This does not replace the local technical engineering task.
6 5822 470 GB

238 VIESMANN System examples


Solar thermal systems (cont.)

Equipment required

ID: 4605164_1001_01
Pos. Description Part no.
1 Oil/gas boilers As per Viessmann pricelist
with
2 Boiler and heating circuit control unit part of the standard delivery of pos.
1
3 Cylinder temperature sensor part of the standard delivery of pos.
2
4 Circulation pump for cylinder heating As per Viessmann pricelist
qI DHW cylinder 2, mono-mode As per Viessmann pricelist
qP DHW cylinder 1, mono-mode As per Viessmann pricelist
qQ Cylinder temperature sensor S2 (SOL) part of the standard delivery of pos.
36
qW High limit safety cut-out STB Z001 889
qE DHW circulation pump ZP As per Vitoset pricelist
qR Automatic thermostatic mixing valve 7438 940
qT Circulation pump R5/R7 (transfer) As per Vitoset pricelist
qZ Temperature sensor S7 7426 247
qU Temperature sensor S8 7426 247
eP Solar collectors As per Viessmann pricelist
eQ Collector temperature sensor S1 (KOL) part of the standard delivery of pos.
36
eW Solar-Divicon 7188 391 or 7188 392
eE Solar circuit pump R1 part of the standard delivery of pos.
32
eZ Vitosolic 200, type SD4 Z007 388
eU Junction box on-site
eI ON/OFF switch on-site
eO Contactor relay 7814 681
Central heating with solar energy
rP Heating water buffer cylinder on-site
eR Solar pump line 7188 393 or 7188 394
eT Solar circuit pump for heating buffer cylinder R4 part of the standard delivery of pos.
34
rQ Temperature sensor S4 (heating water buffer cylinder), heating up part of the standard delivery of pos.
36
rE Temperature sensor S5 (heating water buffer cylinder), discharge 7426 247
rR High limit safety cut-out STB Z001 889
rT Return temperature sensor S6 (heating circuit) 7426 247
rZ 3-way diverter valve R6 7814 924
Accessories
uQ Solar cell 7408 877
uW Heat meter extension kit (flow meter) As per Viessmann pricelist
uE Large display 7438 325 6
uR Datalogger As per Viessmann pricelist
For boiler and heating circuit accessories, see boiler scheme
5822 470 GB

System examples VIESMANN 239


Solar thermal systems (cont.)

Electrical installation scheme

eI

230 V / 50 Hz
eZ

L 35
N
?
eU 3
R134 M eE
3
R233 STBqW
230 V / 50 Hz

R332 2 eU 3
R431 M eT M
3 1~ qT
STB rR
R530
3
R629 M rZ
R7-R
R7-M
R7-A
2
S1 KOL eQ eO
2
S2 SOL qQ
S3 2
S4 rQ
2
S5 rE
2
S6 rT
Low voltage

2
S7 qZ
2
S8 qU
S12 2
CS10 uQ
2
Imp 1 uW
2
Imp 2 uW
2
V BUS uE/uR
2
145 KM BUS

6
ID: 4605164_1001_01
5822 470 GB

240 VIESMANN System examples


! "#$  
 %&

   
  
      

You might also like