You are on page 1of 1

PVSYST V5.

06 25/09/17

Stand-alone system presizing


Geographical Site Bouira Country Algeria
Situation Latitude 36.4N Longitude 3.9E
Time defined as Solar Time Altitude 519 m
Collector Plane Orientation Tilt 36 Azimuth 0

System pre-sizing evaluation


Average use of energy Daily 2.9 kWh/day Yearly 1073 kWh
Autonomy 4.0 days
Loss-of-Load Time fraction 5.0 % Missing energy 53 kWh
Battery system Voltage 24 V Capacity 543 Ah
PV array Nominal power 860 Wp Nominal Current 28 A
Economic gross evaluation Investment 11878 EUR Energy price 1.57 EUR/kWh

PV energy yield and user's needs Battery SOC and Loss-of-Load Probability
5 120
Available Solar energy 3.6 kWh/day Average State of Charge of batteries 70.0 %
User's needs 2.9 kWh/day Probability of Loss of Load 5.0 %

100
4

80
Energy [kWh/day]

3
%

60

2
40

1
20

0 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Year

Incid. PV avail. Demand Excess Missing SOC Pr. LOL Fuel

kWh/m.day kWh kWh kWh kWh % % liter


Jan. 3.9 83.6 91.1 0.0 17.6 21 20.1 11.8
Feb. 4.7 90.4 82.3 0.0 5.1 26 6.2 3.4
Mar. 5.5 118.4 91.1 6.6 0.0 64 0.0 0.0
Apr. 5.9 121.7 88.2 22.8 0.0 93 0.0 0.0
May 6.0 127.5 91.1 25.4 0.0 95 0.0 0.0
June 6.3 129.3 88.2 30.5 0.0 96 0.0 0.0
July 6.3 134.9 91.1 32.8 0.0 96 0.0 0.0
Aug. 6.3 134.8 91.1 32.7 0.0 96 0.0 0.0
Sep. 6.0 123.8 88.2 25.0 0.0 96 0.0 0.0
Oct. 5.0 107.2 91.1 7.9 0.0 88 0.0 0.0
Nov. 3.9 81.5 88.2 0.0 6.5 46 7.4 4.3
Dec. 3.5 74.6 91.1 0.0 23.8 19 26.1 15.8
Year 5.3 1327.5 1073.1 183.7 53.0 70 5.0 35.3