Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 1
REF CPD-01 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3100 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.9 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 2
REF CPD-02 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 2850 kN


Max Ten Force Ft = 500 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 3.15 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00088

m = 0.00029
Wcr = 0.1 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 3
REF CPD-03 Dwg Reference: OUTPUT

Diameter of Pile D = 1000 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 194 mm
Percentage Rebar 0.52 %
Rebar provided = 13 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 5500 kN


Max Ten Force Ft = 250 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 4085.71 mm2


Ac = 781629 mm2
Fs = 2.53 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 1071.27 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 194 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 106 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00031

m = -0.00033
Wcr = -0.11 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 4
REF CPD-04 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 2750 kN


Max Ten Force Ft = 500 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 3.26 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00088

m = 0.00029
Wcr = 0.100 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 5
REF CPD-05 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3400 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.64 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 6
REF CPD-06 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 4400 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.04 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 7
REF CPD-07 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 190 mm
Percentage Rebar 0.63 %
Rebar provided = 10 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 4250 kN


Max Ten Force Ft = 750 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.63 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 3142.86 mm2


Ac = 499714 mm2
Fs = 2.14 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 824.057 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 190 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 104 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00119

m = 0.00066
Wcr = 0.21 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 8
REF CPD-08 Dwg Reference: OUTPUT

Diameter of Pile D = 1000 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 207 mm
Percentage Rebar 1.24 %
Rebar provided = 12 T 32

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 7850 kN


Max Ten Force Ft = 300 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 1.24 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 9654.86 mm2


Ac = 776059 mm2
Fs = 2.01 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 2531.5 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 207 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 109 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00016

m = -0.00011
Wcr = -0.04 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 9
REF CPD-09 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3300 kN


Max Ten Force Ft = 600 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.72 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00106

m = 0.00047
Wcr = 0.16 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 10
REF CPD-10 Dwg Reference: OUTPUT

Diameter of Pile D = 1000 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 194 mm
Percentage Rebar 0.52 %
Rebar provided = 13 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 6050 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 4085.71 mm2


Ac = 781629 mm2
Fs = 2.30 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 1071.27 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 194 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 106 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00064
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 11
REF CPD-11 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3000 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.99 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 12
REF CPD-12 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 2850 kN


Max Ten Force Ft = 500 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 3.15 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00088

m = 0.00029
Wcr = 0.1 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 13
REF CPD-13 Dwg Reference: OUTPUT

Diameter of Pile D = 1000 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 194 mm
Percentage Rebar 0.52 %
Rebar provided = 13 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 5450 kN


Max Ten Force Ft = 200 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 4085.71 mm2


Ac = 781629 mm2
Fs = 2.55 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 1071.27 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 194 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 106 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.00024

m = -0.00039
Wcr = -0.12 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 14
REF CPD-14 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 2700 kN


Max Ten Force Ft = 450 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 3.32 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0.0008

m = 0.00021
Wcr = 0.07 mm < 0.25, OK !
Project:

Pile Structural Capacity


Mott MacDonald Singapore
Calculations for: Dvn/Dept: Structural Job No./File No. 258520
Rochor Station Calculated by: KKL Date: 16 Aug 2010 Sheet No.
Pile Design Checked by: AW Date: 16 Aug 2010 15
REF CPD-15 Dwg Reference: OUTPUT

Diameter of Pile D = 800 mm Design Status: OK


Concrete Grade fcu = 40 N/mm2 Spacing of Rebar 211 mm
Percentage Rebar 0.57 %
Rebar provided = 9 T 20

Dia of link = 13 mm

Cover to link = 75 mm

Max Com Force Fc = 3500 kN


Max Ten Force Ft = 0 kN Max Crack width = 0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 % OK !
Structural Capacity
** Compression (CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs Where Fs >= 2 CP4 7.4.5.3

Fs = [0.4fcuAc + 0.75fyAs]/Fc Where As = 2828.57 mm2


Ac = 500029 mm2
Fs = 2.56 > 2, OK !

** Tension
Ultimate Ten Capacity = 0.57*fy*As (LTA DC - 6.2.3.9)
= 741.651 kN > Ft, OK !
Tension Crack width (CP 73 - Annex B7)
Crack width Location Co = 53 mm
Spacing of bar S = 211 mm

The equation for the crack width under direct tension only is given by,
Wcr = 3*acr*m
\where,
acr = 113 mm
m = 1 - 2*Ac / (3*Es*As)
1 = Ft / (As*Es)
= 0

m = -0.00059
Wcr = -0.2 mm < 0.25, OK !