CUSTOMER SERVICES DIRECTORATE AIRBUS

1 ROND POINT MAURICE BELLONTE


31707 BLAGNAC CEDEX FRANCE
TELEPHONE + 33 (0)5 61 93 33 33
TELEX AIRBU 530526F SERVICE INFORMATION LETTER

SUBJECT: ATA 35-20 OXYGEN GENERATOR AND OXYGEN CONTAINER


INTERCHANGEABILITY

ATA CHAPTER: 35-20

AIRCRAFT TYPE: A318, A319, A320, A321, A300-600, A310, A330, A340, A340-500/600.

APPLICABILITY: Aircraft equipped with chemical oxygen containers.

REFERENCES: FCOM 2.04.20 P4 SEQ 001 REV24


FCOM 2.04.20 P4 SEQ 100 REV26
Airbus SB 35-1018/ 35-1020/ 35-3008/ 35-4007/ 35-6014/ 35-6015
IPC 35-21
OIT/FOT 999.0079/99 dated 28/08/1999
OEB number 138/1 dated 08/1999
AD 98-301
B/E Aerospace CMM 35-21-20
B/E Aerospace SBs 117019-35-2 Rev.02 and 117028-35-1 Rev. 01
Drger Aerospace CMM 35-21-12
Airbus SIL 35-012
1. PURPOSE:

The aim of this SIL is to avoid possible AOG situations resulting from the non-availability of
appropriate oxygen containers and/or generators when operation under MMEL condition is not
acceptable.
This SIL provides interchangeability information for the passenger chemical oxygen systems
supplied by vendors B/E Aerospace (former Puritan Bennett) and Drger Aerospace.

A complete revision of this SIL was done at revision 02.

Changes in subject SIL are highlighted by a vertical revision bar in the left hand margin
of the respective page.

SIL NUMBER: 35-007


PAGE: 1 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

2. BACKGROUND:

The first issue of this SIL provided the technical interchangeability of B/E Aerospace (Puritan
Bennett) passenger oxygen generators PN 117019-0X (13 minutes), PN 117028-0X (15 minutes)
and PN 117042-0X (15 minutes) within B/E Aerospace containers.
These generators are fitted on A318, A319, A320, A321, A300-600, A310, A330, A340 and A340-
500/600 aircraft.

Revision 1 of this SIL provided:


All the possible technical interchangeabilities between Drger Aerospace and B/E
Aerospace (Puritan Bennett) passenger chemical oxygen containers
All the possible technical interchangeabilities of different B/E Aerospace (Puritan Bennett)
passenger chemical oxygen containers
The non-interchangeability between B/E Aerospace (Puritan Bennett) and Drger
Aerospace oxygen generators.

Revision 2 of this SIL provided (at revision 02 the SIL was entirely reworked):
Additional details about chemical oxygen containers.
An explanation of the part number logic for both vendors.
Interchangeability of new part numbers issued since revision 1 (including the
interchangeability of new part numbers present on A340-500/600 aircraft as well as
A330/A340 with Enhanced Cabin).
Interchangeability of Drger Aerospace chemical oxygen containers.

Revision 3 of this SIL provides:


Updated information for permanent replacement of oxygen generators PN 117019-0X (13
minutes), PN 117028-0X (15 minutes) by oxygen generators PN 117042-0X (15 minutes)
within B/E Aerospace containers with a link to dedicated Airbus SIL 35-012.

Note: A mention SEE SIL 35-007 is found at the level of the oxygen containers in each applicable IPC
35-21.

APPLICABILITY FOR AOG SITUATIONS:

If necessary, the approval for replacement of the oxygen generator (described in paragraph 3.1 and
3.2) as well as container interchangeability (described in paragraph 3.5, 3.6, 3.7 and 3.8) is to be
negotiated independently by the operators with their local Airworthiness Authorities. This should be
done in advance, in order to avoid any additional delay in case of AOG.

The generator replacements presented in this SIL must be limited to AOG cases, since the part
number of the complete oxygen container would have to be changed for permanent
installation/modification. Therefore it is required that the aircraft recover its initial configuration as
soon as the parts are available and not later than within 500 FH.

SIL NUMBER: 35-007


PAGE: 2 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3. DESCRIPTION:

Two vendors - B/E Aerospace (former Puritan Bennett) and Drger Aerospace - supply Airbus
aircraft with passenger oxygen systems.

The cabin emergency chemical oxygen system consists of self-contained oxygen container
assemblies.
Each container assembly is composed of:
- Solid-state chemical oxygen generator(s).
- Continuous flow type oxygen masks with face piece, reservoir bag, flexible tubing and lanyard
connected to the generator (pulling the mask lanyard will pull the release pin and will activate
the oxygen generator).
- An electrical door latching mechanism that opens the container door when supplied with electrical
power. The door can be opened manually thanks to the cabin release tool in case of malfunction.
- A door stop for maintenance/test purpose that allows testing of the door latch mechanism without
deploying the masks.

Container general information:

Container Type Door dimension (mm) Number of masks Common usage


I 305 x 260 2/3/4* Supply channels, ceilings, door
frame linings.

II 260 x 164 2* Side walls, lavatories, low


ceilings, galleys, crew rest
compartments.

III 500 x 176 2/3/4/5 Central high ceiling areas.

V 340 x 254 2/3/4* Supply channels.

VI 600 x 203 2/3/4/5/6* Central supply channels.

(Note: Type IV containers are not used on Airbus aircraft)

* Some Type I, II, V and VI containers are equipped with a PULL Flag attached to the masks. Purpose of the
PULL Flag is to extend the reach envelope of the masks in order to enable users to get access to the emergency
oxygen masks whatever their - standing or seating - position.

SIL NUMBER: 35-007


PAGE: 3 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

B/E AEROSPACE (Puritan Bennett):

The company that was formerly called Puritan-Bennett Aero Systems Co. is now a part of B/E
Aerospace.
In all cases a PN marked B/E Aerospace and the same PN marked "Puritan-Bennett Aero Systems
Co." are fully interchangeable.

Example B/E Aerospace Passenger Oxygen Container Type II


Extracted from CMM 35-21-20 (PN AE5712-XX)

Figure 1

SIL NUMBER: 35-007


PAGE: 4 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

DRAGER AEROSPACE:

Drger Aerospace have been supplying Airbus aircraft with passenger oxygen systems since the early
1990s.

Example Drger Aerospace Passenger Oxygen Container Type I


Extracted from CMM 35-21-12 (1XC15 / 1XC22 Series)

Figure 2

SIL NUMBER: 35-007


PAGE: 5 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.1 OXYGEN GENERATOR INTERCHANGEABILITY

Note: Only some oxygen generators from vendor B/E Aerospace can be interchanged in AOG situation as
per detail found below.

3.1.1 13 minutes replaced by 15 minutes

PN 117019-02, -03, -04 (13 minutes generators) can be replaced by PN 117028-02, -03, -04 or
117042-02, 03, 04 (15 minutes generators).

This replacement can be done without any operational consequences, and does not require any
mechanical adaptation.
(The quantity of heat produced by the 13 and 15 minutes generators is similar).

3.1.2 15 minutes replaced by 13 minutes

15 minutes generators PN 117028-02, -03, -04 and 117042-02, -03, -04 can be replaced by
respectively 13 minutes generators PN 117019-02, -03, -04.

Technically, this replacement requires a minor installation adaptation: This is described in paragraph
3.2.

CAUTION: The installation of 13 minutes generators in place of 15 minutes, implies that the aircraft
is operated in accordance with the possibilities of the equipment installed (i.e. 13 minutes
performance.
This is valid in any case if at least one generator or container 13 minutes is installed at any location
within the aircraft.

MANDATORY: The 15 minutes descent profile indicated in the FCOM must be replaced by a 13
minutes descent profile as shown in examples of figures 3, 4 and 5 (see pages 7 and 8).
For confirmation of correct profile to be used please contact AIRBUS.

SIL NUMBER: 35-007


PAGE: 6 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Figure 3 A300-600/A310 13 minutes descent profile (FCOM 2.18.20 P1)

Figure 4 A318/A319/A320/A321 13 minutes descent profile (FCOM 2.04.20 P4)

SIL NUMBER: 35-007


PAGE: 7 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Figure 5 A330/A340 13 minutes descent profile (FCOM 2.04.20 P3)

SIL NUMBER: 35-007


PAGE: 8 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.2 PROCEDURE FOR GENERATOR SUBSTITUTION (from 15 to 13 minutes)

The replacement of a 15 minutes generator by a 13 minutes generator as described in point 3.1.2,


requires the following minor deviation:

The Figure 6 (on next page) shows an opened oxygen container with its original generator still fitted.

In order to avoid any accidental installation of a different generator type to the one initially fitted,
each generator type is attached with a clamp equipped with a particular safety feature.
This safety feature consists in an index plate, attached to the clamp by spot welding (See Figure 7 on
next page).
This safety feature forbids in addition that a 2-mask generator can be accidentally confused with a 3-
mask generator and so on.

PROCEDURE: In order to allow the installation of 13 minutes generators in the 15 minutes type
mounting clamp the generator has to be rotated slightly, so that the index lug goes beside the index
plate, rather than engaging the plate. Then the lug does not engage the holes, and either generator can
be installed in either container type (See Figure 7).

CAUTION: To avoid any accidental installation of incorrect oxygen generators this deviation must be
done on purpose, properly traced and limited to AOG cases for a limited duration (maximum 500FH).

SIL NUMBER: 35-007


PAGE: 9 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

FIGURE 6

Index Lug

Index Plate

FIGURE 7

SIL NUMBER: 35-007


PAGE: 10 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.3 PERMANENT REPLACEMENT OF OXYGEN GENERATORS (B/E Aerospace)

Today when the 15 years lifetime limit of the oxygen generators PN 117019-0X (13 minutes - early
model) or PN 117028-0X (15 minutes - early model) is reached, the different spare part vendors
propose to use the latest models PN 117042-0X (15 minutes) as a replacement.
Although B/E Aerospace have confirmed several times to AIRBUS that these early model
generators are still procurable their lead-time is higher than for latest design generators (PN
117042-0x).

In order to allow customers to permanently replace the early models oxygen generators PN
117019-0X (13 minutes) or PN 117028-0X (15 minutes) by the latest models PN 117042-0X (15
minutes), B/E Aerospace have issued two Vendor Service Bulletins which have been approved by
Airbus.

Such installation of a new generator PN 117042-0X in a container equipped initially with either PN
117019-0X or PN 117028-0X is traced by addition of a letter C at the end of the container Part
Number.

To perform the modification the Vendor Service Bulletins 117019-35-2 Rev. 02 and 117028-35-1
Rev. 01 have been issued on 09-Jan-06 in order to describe the container modification:
VSB 117019-35-2 Rev. 02 introduces PN 117042-0X (15 min.) as replacement of PN
117019-0X (13 min.).
VSB 117028-35-1 Rev. 01 introduces PN 117042-0X (15 min.) as replacement of PN
117028-0X (15 min.).

For application of any of these VSB please refer to the Airbus SIL 35-012.

IMPORTANT NOTE #1:


The versions approved by AIRBUS for both VSB 117019-35-2 and VSB 117028-35-1 are ONLY
the revisions issued on or after 09-Jan-2006.

IMPORTANT NOTE #2:


After application of VSB 117019-35-2 (13 minutes replaced by 15 minutes) it must be highlighted that
the aircraft performance remains UNCHANGED: i.e. the aircraft still have a 13 minutes
performance from a certification stand point.

If an increased performance is needed we remind that the normal procedure is to order a dedicated
Airbus Service Bulletin to the Airbus UPGRADE SERVICES (Mailto:upgrade.services@airbus.com).
This will allow the operational documents (FCOM) to be updated and A/C to be certified for 15 minutes
operation .

SIL NUMBER: 35-007


PAGE: 11 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.4 B/E AEROSPACE (Puritan Bennett) OXYGEN GENERATORS NOT INTERCHANGEABLE

3.4.1 13.5 min. GENERATORS PN 117010-0X

The oldest oxygen generators PN 117010-0X (13.5 minutes) installed on first A300 aircraft are not
interchangeable with other generator models PN 117016-0X, 117019-XX, 117028-XX, 117042-XX
for the following reasons:

Interfaces of these generators are different from one to another, in particular the fixation in the
container.
The generator PN 117016-0X series are not qualified for fixation in a container with a single clamp.
The flow characteristics are different (different descent profile).

3.4.2 15 min. GENERATORS PN 117016-0X

The oxygen generators PN 117016-0X (15 minutes) and PN 117019-XX, 117028-XX, 117042-
XX (13 & 15 minutes) are not interchangeable due to the same reasons as explained in above
paragraph 3.4.1.

3.4.3 14 min. High flow GENERATORS PN 117019-3X

The oxygen generators PN 117019-3X (14 minutes) and PN 117019-XX, 117028-XX, 117042-XX
(13 & 15 minutes) are not interchangeable for the following reasons:

Dimensions are not compatible.


PN 117019-3X is heavier.
PN 117019-3X produces more heat.
The flow characteristics are different (different descent profile).

3.4.4 22 min. GENERATORS PN 117019-2X, PN 117028-2X & PN 117042-2X

The 22 minutes generators PN 117019-2X, PN 117028-2X & PN 117042-2X are not interchangeable
with other generator models PN 117016-0X, 117019-XX, 117028-0X, 117042-0X series mainly due
to dimensions that are not compatible.

3.5 DRGER AEROSPACE OXYGEN GENERATORS NOT INTERCHANGEABLE

NONE of the oxygen generators manufactured by Drger Aerospace (15 minutes and 22 minutes) are
interchangeable for the following reasons:

22 minutes and 15 minutes generators have different contours.


Both generators 15 and 22 minutes have different attachment principle.

SIL NUMBER: 35-007


PAGE: 12 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.6 B/E AEROSPACE (PURITAN BENNETT) - CONTAINER INTERCHANGEABILITY

Example of B/E Aerospace Part Number:

G 1 L 1 2 3 XX
DOOR COLOUR code

NUMBER OF MASKS

MASK TUBING LENGTH code

MASK LANYARD LENGTH code

CONTAINER ORIENTATION code


L = Left - Type I R= Right -Type II
F = Pull flag present Type II
N = No pull flag- Types II & III

TYPE OF CONTAINER
1 = Type I
2 = Type II
3 = Type III
CONTAINER SERIES code.
This code incorporates several variables.
S, G, W, E series are applicable to this convention.

Series S denotes a unit containing a generator providing 15 minutes supply of oxygen and a
grey profile colour. Series S uses a muscle wire latch, which has been made obsolete and
was replaced by a solenoid latch (becomes series G).
Series G denotes a 15 minutes generator and a grey profile colour. This series uses a
solenoid latch and replaces series S.
Series W denotes a 15 minutes generator and a white profile colour.
Series E denotes a 22 minutes generator and a grey profile colour.

For more detail on the retrofit from series S to series G please refer to:
OIT/FOT 999.0079/99 dated 28 August 1999
OEB number 138/1 dated August 1999
AI SB's A320-35-1020 and A300-35-6015

Other series of B/E Aerospace oxygen containers exist with different Part Number structure.
For full detail on any container specification we recommend to refer to the associated CMM.
3.6.1 DOOR COLOUR

SIL NUMBER: 35-007


PAGE: 13 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

The door colour (last two digits XX of the part number) does not have any effect on the container
performance or technical interchangeability.

Consequently the decision to fit a container with a different colour is only let to the operator
decision.

3.6.2 FIXATION PROFILE COLOUR

Fixation profiles may have different colours that may be more or less visible to the persons present
in the cabin.
However mixing of brown, grey and white profiles has no impact on the container performance or
interchangeability.

Again the decision to fit a container with a different profile colour is let to the operator decision.

SIL NUMBER: 35-007


PAGE: 14 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.6.3 B/E AEROSPACE CONTAINER INTERCHANGEABILITY CONDITIONS

Tables 1a) to 1d) detail the interchangeability for all B/E Aerospace (formerly Puritan Bennett)
container part numbers between themselves.

Interchangeability is possible unconditionally only if all following criteria are fulfilled:


Container type is identical.
Door opening orientation is identical.
Lanyard length and tube length are identical.
Number of masks is identical or is HIGHER
(for example PN AH5L43-XX can be replaced by PN E1L324-XX but not by PN E1L322-XX).
Oxygen supply duration is identical or is HIGHER.

Interchangeability is possible WITH CONDITION if:


All criteria above mentioned are fulfilled except that:
Oxygen supply duration is LOWER.

CONDITION: The installation of 13 minutes container in place of 15 minutes, or 15 minutes


container in place of 22 minutes, or 13 minutes container in place of 22 minutes implies that the
aircraft is operated in accordance with the lowest performance of the equipment installed (i.e. 13
or 15 minutes performance).
This is valid in any case if at least one container 13 or 15 minutes is installed at any location
within the aircraft.

MANDATORY: The emergency descent profile indicated in the FCOM of the affected aircraft
must be replaced by a new descent profile adapted to the new performance.
For confirmation of correct profile to be used please contact AIRBUS.
ALSO the crew must be clearly informed of this temporary change.

Any of the above interchangeability (with or without condition) applies to AOG situations only.
Therefore it is required for the aircraft to recover its original configuration at the earliest
opportunity and within 500FH at the latest.

SIL NUMBER: 35-007


PAGE: 15 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

B/E Aerospace PN Interchangeability - For information and AOG purpose only

Table 1a):
Type I Passenger Oxygen Containers Left-Hand Units

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.6.3

Two way Two way Two way

Dark Quartz Dark Quartz Quartz Quartz Dark Quartz Quartz Quartz
Brown Grey Brown Grey Grey Grey Beige Brown Grey Grey Grey
Container Number Lanyard Tube Profile Profile Profile Profile Profile Profile Profile profile profile Profile Profile
type of Masks Length Length 13 Min 13 Min 15 Min 15 Min 15 Min 15 Min 15 Min 22 Min 22 Min 22 Min 22 Min
(Inches) (Inches) PN PN PN PN PN PN PN PN PN PN PN

I 2 person 10 60 AH5L32-XX AJ5L32-XX AE5L32-XX AF5L32-XX S1L122-XX G1L122-XX W1L122-XX AE6L32-XX AF6L32-XX AG5L32-XX E1L122-XX
I 3 person 10 60 AH5L33-XX AJ5L33-XX AE5L33-XX AF5L33-XX S1L123-XX G1L123-XX W1L123-XX AE6L33-XX AF6L33-XX AG5L33-XX E1L123-XX
I 4 person 10 60 AH5L34-XX AJ5L34-XX AE5L34-XX AF5L34-XX S1L124-XX G1L124-XX W1L124-XX AE6L34-XX AF6L34-XX N/A E1L124-XX

I 2 person 24 60 AH5L42-XX AJ5L42-XX AE5L42-XX AF5L42-XX S1L322-XX G1L322-XX W1L322-XX AE6L42-XX AF6L42-XX AG5L42-XX E1L322-XX
I 3 person 24 60 AH5L43-XX AJ5L43-XX AE5L43-XX AF5L43-XX S1L323-XX G1L323-XX W1L323-XX AE6L43-XX AF6L43-XX AG5L43-XX E1L323-XX
I 4 person 24 60 AH5L44-XX AJ5L44-XX AE5L44-XX AF5L44-XX S1L324-XX G1L324-XX W1L324-XX AE6L44-XX AF6L44-XX N/A E1L324-XX

I 2 person 40 84 N/A N/A AE5L52-XX AF5L52-XX S1L642-XX G1L642-XX W1L642-XX AE6L52-XX AF6L52-XX N/A E1L642-XX
I 3 person 40 84 N/A N/A AE5L53-XX AF5L53-XX S1L643-XX G1L643-XX W1L643-XX AE6L53-XX AF6L53-XX N/A E1L643-XX
I 4 person 40 84 N/A N/A AE5L54-XX AF5L54-XX S1L644-XX G1L644-XX W1L644-XX AE6L54-XX AF6L54-XX N/A E1L644-XX

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.6.3 are met.

SIL NUMBER: 35-007


PAGE: 16 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

B/E Aerospace PN Interchangeability - For information and AOG purpose only

Table 1b):
Type I Passenger Oxygen Containers Right-Hand Units

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.6.3

Two way Two way Two way

Dark Quartz Dark Quartz Quartz Quartz Dark Quartz Quartz Quartz
Brown Grey Brown Grey Grey Grey Beige Brown Grey Grey Grey
Container Number Lanyard Tube Profile Profile 13 Profile Profile Profile Profile Profile profile profile Profile Profile
type of Masks Length Length 13 Min Min 15 Min 15 Min 15 Min 15 Min 15 Min 22 Min 22 Min 22 Min 22 Min
(Inches) (Inches) PN PN PN PN PN PN PN PN PN PN PN

I 2 person 10 60 AH5R32-XX AJ5R32-XX AE5R32-XX AF5R32-XX S1R122-XX G1R122-XX W1R122-XX AE6R32-XX AF6R32-XX AG5R32-XX E1R122-XX
I 3 person 10 60 AH5R33-XX AJ5R33-XX AE5R33-XX AF5R33-XX S1R123-XX G1R123-XX W1R123-XX AE6R33-XX AF6R33-XX AG5R33-XX E1R123-XX
I 4 person 10 60 AH5R34-XX AJ5R34-XX AE5R34-XX AF5R34-XX S1R124-XX G1R124-XX W1R124-XX AE6R34-XX AF6R34-XX N/A E1R124-XX

I 2 person 24 60 AH5R42-XX AJ5R42-XX AE5R42-XX AF5R42-XX S1R322-XX G1R322-XX W1R322-XX AE6R42-XX AF6R42-XX AG5R42-XX E1R322-XX
I 3 person 24 60 AH5R43-XX AJ5R43-XX AE5R43-XX AF5R43-XX S1R323-XX G1R323-XX W1R323-XX AE6R43-XX AF6R43-XX AG5R43-XX E1R323-XX
I 4 person 24 60 AH5R44-XX AJ5R44-XX AE5R44-XX AF5R44-XX S1R324-XX G1R324-XX W1R324-XX AE6R44-XX AF6R44-XX N/A E1R324-XX

I 2 person 40 84 N/A N/A AE5R52-XX AF5R52-XX S1R642-XX G1R642-XX W1R642-XX AE6R52-XX AF6R52-XX N/A E1R642-XX
I 3 person 40 84 N/A N/A AE5R53-XX AF5R53-XX S1R643-XX G1R643-XX W1R643-XX AE6R53-XX AF6R53-XX N/A E1R643-XX
I 4 person 40 84 N/A N/A AE5R54-XX AF5R54-XX S1R644-XX G1R644-XX W1R644-XX AE6R54-XX AF6R54-XX N/A E1R644-XX

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.6.3 are met.

SIL NUMBER: 35-007


PAGE: 17 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

B/E Aerospace PN Interchangeability - For information and AOG purpose only

Table 1c):
Type II Passenger Oxygen Containers (with and without PULL FLAG)

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.6.3

Two way Two way

Container Number Lanyard Tube 13 Min 15 Min 15 Min 15 Min 22 Min 22 Min 22 Min
type of Masks Length Length PN PN PN PN PN PN PN
(Inches) (Inches) WB only

II 2 person 19.5 48 AH5702-XX AE5702-XX S2F212-XX G2F212-XX AE6702-XX AG5702-XX E2F212-XX


(with (27 with
FLAG) FLAG)
II 2 person 19.5 48 AH5722-XX AE5722-XX S2N212-XX G2N212-XX AE6722-XX AG5722-XX E2N212-XX
II 2 person 27 60 AH5712-XX AE5712-XX S2N422-XX G2N422-XX AE6712-XX AG5712-XX E2N422-XX
II 2 person 40 75 AH5732-XX AE5732-XX S2N632-XX G2N632-XX AE6732-XX AG5732-XX E2N632-XX
II 2 person 10 60 AH5742-XX AE5742-XX S2N122-XX G2N122-XX AE6742-XX AG5742-XX E2N122-XX

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.6.3 are met.

SIL NUMBER: 35-007


PAGE: 18 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

B/E Aerospace PN Interchangeability - For information and AOG purpose only

Table 1d):
Type III Passenger Oxygen Containers

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.6.3

Two way Two way Two way

Grey
Brown Grey Brown Grey Grey Grey White Brown Grey Profile Grey
Container Number Lanyard Tube Profile Profile Profile Profile Profile Profile Profile profile profile 22 Min Profile
type of Masks Length Length 13 Min 13 Min 15 Min 15 Min 15 Min 15 Min 15 Min 22 Min 22 Min PN 22 Min
(Inches) (Inches) PN PN PN PN PN PN PN PN PN WB only PN

III 2 person 27 75 AH5H62-XX AJ5H62-XX AE5H62-XX AF5H62-XX S3N432-XX G3N432-XX W3N432-XX AE6H62-XX AF6H62-XX AG5H62-XX E3N432-XX
III 3 person 27 75 AH5H63-XX AJ5H63-XX AE5H63-XX AF5H63-XX S3N433-XX G3N433-XX W3N433-XX AE6H63-XX AF6H63-XX AG5H63-XX E3N433-XX
III 4 person 27 75 AH5H64-XX AJ5H64-XX AE5H64-XX AF5H64-XX S3N434-XX G3N434-XX W3N434-XX AE6H64-XX AF6H64-XX AG5H64-XX E3N434-XX
III 5 person 27 75 AH5H65-XX AJ5H65-XX AE5H65-XX AF5H65-XX S3N435-XX G3N435-XX W3N435-XX N/A N/A N/A E3N435-XX

III 2 person 38 84 AH5H52-XX AJ5H52-XX AE5H52-XX AF5H52-XX S3N542-XX G3N542-XX W3N542-XX AE6H52-XX AF6H52-XX AG5H52-XX E3N542-XX
III 3 person 38 84 AH5H53-XX AJ5H53-XX AE5H53-XX AF5H53-XX S3N543-XX G3N543-XX W3N543-XX AE6H53-XX AF6H53-XX AG5H53-XX E3N543-XX
III 4 person 38 84 AH5H54-XX AJ5H54-XX AE5H54-XX AF5H54-XX S3N544-XX G3N544-XX W3N544-XX AE6H54-XX AF6H54-XX AG5H54-XX E3N544-XX
III 5 person 38 84 AH5H55-XX AJ5H55-XX AE5H55-XX AF5H55-XX S3N545-XX G3N545-XX W3N545-XX N/A N/A N/A E3N545-XX

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.6.3 are met.

SIL NUMBER: 35-007


PAGE: 19 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.7 DRGER AEROSPACE - CONTAINER INTERCHANGEABILITY

Part Number Logic

The convention and logic for Drger Aerospace part numbers is explained below. Also see the
Component Maintenance Manual (CMM) chapter corresponding to the container part number
concerned.

Example part number:

1 3 C 15 L 2 1 1 18 0004
MODIFICATION Code
A higher number indicates a later evolution

DOOR ASSEMBLY COLOUR Code

PROFILE COLOUR Code

LANYARD LENGTH Code

TUBE LENGTH Code


INSTALLATION SIDE Code
L Left Hand
R Right Hand
0 Not applicable

MIN. DURATION OF OXYGEN


PRODUCTION in minutes

SYSTEM OF OXYGEN PRODUCTION


C = Chemical
G = Gaseous

NUMBER OF MASKS

CONTAINER TYPE Code


1 up to 6 exist signifying different dimensions
(Code 4 is not used)

SIL NUMBER: 35-007


PAGE: 20 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.7.1 DESIGN EVOLUTION CODES

Four series of passenger oxygen container are currently in use.


Their part numbers end in the design evolution codes 0003, 0004, 0005 or 0006.
These four series have all been produced against the same specification. Hence, they are all fully two
way interchangeable.

Series 0000 and 0001 must have been modified in accordance with SBs, 35-1018, 35-6014, 35-3008
and 35-4007, which were made mandatory by AD 98-301.
This also means that series 0000 and 0001 must not be used.

Note: Serie 0002 has never been produced.

3.7.2 DOOR COLOUR

The door colour (last two digits XX of the part number) does not have any effect on the container
performance or technical interchangeability.

Consequently the decision to fit a container with a different colour is only let to the operator
decision.

3.7.3 FIXATION PROFILE COLOUR

Fixation profiles may have different colours that may be more or less visible to the persons present in
the cabin.
However mixing of brown, grey and white profiles has no impact on the container performance or
interchangeability.

Again the decision to fit a container with a different profile colour is let to the operator decision.

SIL NUMBER: 35-007


PAGE: 21 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.7.4 DRGER AEROSPACE CONTAINER INTERCHANGEABILITY CONDITIONS

Tables 2a) to 2i) detail the interchangeability for all Drger Aerospace container part numbers.

Interchangeability is possible unconditionally only if all following criteria are fulfilled:


Container type is identical.
Door opening orientation is identical.
Lanyard length and tube length are identical.
Number of masks is identical or is HIGHER.
(for example PN 13C15L232XX0004 can be replaced by PN 14C22L23XXX0005 but not by PN
12C22L23XXX0005).
Oxygen supply duration is identical or is HIGHER.
Part numbers used ends with design evolution code 0003 or 0004 or 0005 or 0006.

Interchangeability is possible WITH CONDITION if:


All criteria above mentioned are fulfilled except that:
Oxygen supply duration is LOWER.

CONDITION: The installation of 13 minutes container in place of 15 minutes, or 15 minutes


container in place of 22 minutes, or 13 minutes container in place of 22 minutes implies that the
aircraft is operated in accordance with the lowest performance of the equipment installed (i.e. 13
or 15 minutes performance).
This is valid in any case if at least one container 13 or 15 minutes is installed at any location
within the aircraft.

MANDATORY: The emergency descent profile indicated in the FCOM of the affected aircraft
must be replaced by a new descent profile adapted to the new performance.
For confirmation of correct profile to be used please contact AIRBUS.
ALSO the crew must be clearly informed of this temporary change.

Any of the above interchangeability (with or without condition) applies to AOG situations only.
Therefore it is required for the aircraft to recover its original configuration at the earliest opportunity
and within 500FH at the latest.

SIL NUMBER: 35-007


PAGE: 22 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2a):
Type I Passenger Oxygen Containers Left-Hand Units

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Tube 15 minutes O2 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2 22 minutes O2
type of Masks Length Length Supply Supply Supply Supply Supply Supply
(Inches) (Inches) 3rd Evolution 4th Evolution 5th Evolution 3rd Evolution 4th Evolution 5th Evolution

I 2 person 10 60 12C15L21YXX0003 12C15L212XX0004 12C15L212XX0005 12C22L21YXX0003 12C22L212XX0004 12C22L212XXX0005


I 3 person 10 60 13C15L21YXX0003 13C15L212XX0004 13C15L212XX0005 13C22L21YXX0003 13C22L212XX0004 13C22L212XXX0005
I 4 person 10 60 14C15L21YXX0003 14C15L212XX0004 14C15L212XX0005 14C22L21YXX0003 14C22L212XX0004 14C22L212XXX0005

I 2 person 24 60 12C15L23YXX0003 12C15L232XX0004 12C15L232XX0005 12C22L23YXX0003 12C22L232XX0004 12C22L232XXX0005


I 3 person 24 60 13C15L23YXX0003 13C15L232XX0004 13C15L232XX0005 13C22L23YXX0003 13C22L232XX0004 13C22L232XXX0005
I 4 person 24 60 14C15L23YXX0003 14C15L232XX0004 14C15L232XX0005 14C22L23YXX0003 14C22L232XX0004 14C22L232XXX0005

I 2 person 40 84 12C15L47YXX0003 12C15L474XX0004 12C15L474XX0005 12C22L47YXX0003 12C22L474XX0004 12C22L474XXX0005


I 3 person 40 84 13C15L47YXX0003 13C15L474XX0004 13C15L474XX0005 13C22L47YXX0003 13C22L474XX0004 13C22L474XXX0005
I 4 person 40 84 14C15L47YXX0003 14C15L474XX0004 14C15L474XX0005 14C22L47YXX0003 14C22L474XX0004 14C22L474XXX0005

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 23 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2b):
Type I Passenger Oxygen Containers Right-Hand Units

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Tube 15 minutes O2 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2 22 minutes O2
type of Masks Length Length Supply Supply Supply Supply Supply Supply
(Inches) (Inches) 3rd Evolution 4th Evolution 5th Evolution 3rd Evolution 4th Evolution 5th Evolution

I 2 person 10 60 12C15R21YXX0003 12C15R212XX0004 12C15R212XX0005 12C22R21YXX0003 12C22R212XX0004 12C22R212XXX0005


I 3 person 10 60 13C15R21YXX0003 13C15R212XX0004 13C15R212XX0005 13C22R21YXX0003 13C22R212XX0004 13C22R212XXX0005
I 4 person 10 60 14C15R21YXX0003 14C15R212XX0004 14C15R212XX0005 14C22R21YXX0003 14C22R212XX0004 14C22R212XX-0005

I 2 person 24 60 12C15R23YXX0003 12C15R232XX0004 12C15R232XX0005 12C22R23YXX0003 12C22R232XX0004 12C22R232XXX0005


I 3 person 24 60 13C15R23YXX0003 13C15R232XX0004 13C15R232XX0005 13C22R23YXX0003 13C22R232XX0004 13C22R232XXX0005
I 4 person 24 60 14C15R23YXX0003 14C15R232XX0004 14C15R232XX0005 14C22R23YXX0003 14C22R232XX0004 14C22R232XXX0005

I 2 person 40 84 12C15R47YXX0003 12C15R474XX0004 12C15R474XX0005 12C22R47YXX0003 12C22R474XX0004 12C22R474XXX0005


I 3 person 40 84 13C15R47YXX0003 13C15R474XX0004 13C15R474XX0005 13C22R47YXX0003 13C22R474XX0004 13C22R474XXX0005
I 4 person 40 84 14C15R47YXX0003 14C15R474XX0004 14C15R474XX0005 14C22R47YXX0003 14C22R474XX0004 14C22R474XXX0005

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 24 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2c):
Type II Passenger Oxygen Containers (with and without PULL FLAG)

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Tube 15 minutes O2 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2 22 minutes O2
type of Masks Length Length Supply Supply Supply Supply Supply Supply
(Inches) (Inches) 3rd Evolution 4th Evolution 5th Evolution 3rd Evolution 4th Evolution 5th Evolution

II 2 person 19.5 48 22C150150XX0003 22C150150XX0004 22C150150XXX0005 22C220150XX0003 22C220150XX0004 22C220150XXX0005


(with (27 with
FLAG) FLAG)
II 2 person 19.5 48 22C150120XX0003 22C150120XX0004 22C150120XXX0005 22C220120XX0003 22C220120XX0004 22C220120XXX0005
II 2 person 27 60 22C150240XX0003 22C150240XX0004 22C150240XXX0005 22C220240XX0003 22C220240XX0004 22C220240XXX0005
II 2 person 40 75 22C150370XX0003 22C150370XX0004 22C150370XXX0005 22C220370XX0003 22C220370XX0004 22C220370XXX0005
II 2 person 10 60 22C150210XX0003 22C150210XX0004 22C150210XXX0005 22C220210XX0003 22C220210XX0004 22C220210XXX0005

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 25 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2d):
Type III Passenger Oxygen Containers

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Tube 15 minutes O2 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2 22 minutes O2
type of Masks Length Length Supply Supply Supply Supply Supply Supply
(Inches) (Inches) 3rd Evolution 4th Evolution 5th Evolution 3rd Evolution 4th Evolution 5th Evolution

III 2 person 27 75 32C15034YXX0003 32C150342XX0004 32C150342XXX0005 32C22034YXX0003 32C220342XX0004 32C220342XXX0005


III 3 person 27 75 33C15034YXX0003 33C150342XX0004 33C150342XXX0005 33C22034YXX0003 33C220342XX0004 33C220342XXX0005
III 4 person 27 75 34C15034YXX0003 34C150342XX0004 34C150342XXX0005 34C22034YXX0003 34C220342XX0004 34C220342XXX0005
III 5 person 27 75 35C15034YXX0003 35C150342XX0004 35C150342XXX0005 35C22034YXX0003 35C220342XX0004 35C220342XXX0005

III 2 person 38 84 32C15046YXX0003 32C150462XX0004 32C150462XXX0005 32C22046YXX0003 32C220462XX0004 32C220462XXX0005


III 3 person 38 84 33C15046YXX0003 33C150462XX0004 33C150462XXX0005 33C22046YXX0003 33C220462XX0004 33C220462XXX0005
III 4 person 38 84 34C15046YXX0003 34C150462XX0004 34C150462XXX0005 34C22046YXX0003 34C220462XX0004 34C220462XXX0005
III 5 person 38 84 35C15046YXX0003 35C150462XX0004 35C150462XXX0005 35C22046YXX0003 35C220462XX0004 35C220462XXX0005

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 26 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER


Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2e):
Type V Passenger Oxygen Containers

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Tube 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2


type of Masks Length Length Supply Supply Supply Supply
(Inches) (Inches) 5th Evolution 6th Evolution 5th Evolution 6th Evolution

V 2 person 13 70 52C1505A0XX0005 52C1505A0XX0006 52C2205A0XX0005 52C2205A0XX0006


V 3 person 13 70 53C1505A0XX0005 53C1505A0XX0006 53C2205A0XX0005 53C2205A0XX0006
V 4 person 13 70 54C1505A0XX0005 54C1505A0XX0006 54C2205A0XX0005 54C2205A0XX0006

V 2 person 22 70 52C1505E0XX0005 52C1505E0XX0006 52C2205E0XX0005 52C2205E0XX0006


V 3 person 22 70 53C1505E0XX0005 53C1505E0XX0006 53C2205E0XX0005 53C2205E0XX0006
V 4 person 22 70 54C1505E0XX0005 54C1505E0XX0006 54C2205E0XX0005 54C2205E0XX0006

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 27 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2f):
Type V Passenger Oxygen Containers WITH PULLFLAG

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Length / Tube 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2


type of Masks with FLAG Length Supply Supply Supply Supply
(Inches) (Inches) 5th Evolution 6th Evolution 5th Evolution 6th Evolution

V 2 person 13 / 25 70 52C1505F0XX0005 52C1505F0XX0006 52C2205F0XX0005 52C2205F0XX0006


V 3 person 13 / 25 70 53C1505F0XX0005 53C1505F0XX0006 53C2205F0XX0005 53C2205F0XX0006
V 4 person 13 / 25 70 54C1505F0XX0005 54C1505F0XX0006 54C2205F0XX0005 54C2205F0XX0006

V 2 person 30 / 42 80 52C1506K0XX0005 52C1506K0XX0006 52C2206K0XX0005 52C2206K0XX0006


V 3 person 30 / 42 80 53C1506K0XX0005 53C1506K0XX0006 53C2206K0XX0005 53C2206K0XX0006
V 4 person 30 / 42 80 54C1506K0XX0005 54C1506K0XX0006 54C2206K0XX0005 54C2206K0XX0006

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 28 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2g):
Type V Passenger Oxygen Containers WITH SPRING LOADED DOOR

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Tube 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2


type of Masks Length Length Supply Supply Supply Supply
(Inches) (Inches) 5th Evolution 6th Evolution 5th Evolution 6th Evolution

V 2 person 13 70 52C15S5A0XX0005 52C15S5A0XX0006 52C22S5A0XX0005 52C22S5A0XX0006


V 3 person 13 70 53C15S5A0XX0005 53C15S5A0XX0006 53C22S5A0XX0005 53C22S5A0XX0006
V 4 person 13 70 54C15S5A0XX0005 54C15S5A0XX0006 54C22S5A0XX0005 54C22S5A0XX0006

V 2 person 22 70 52C15S5E0XX0005 52C15S5E0XX0006 52C22S5E0XX0005 52C22S5E0XX0006


V 3 person 22 70 53C15S5E0XX0005 53C15S5E0XX0006 53C22S5E0XX0005 53C22S5E0XX0006
V 4 person 22 70 54C15S5E0XX0005 54C15S5E0XX0006 54C22S5E0XX0005 54C22S5E0XX0006

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 29 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2h):
Type VI Passenger Oxygen Containers

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Tube 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2


type of Masks Length Length Supply Supply Supply Supply
(Inches) (Inches) 5th Evolution 6th Evolution 5th Evolution 6th Evolution

VI 2 person 18 70 62C1505B0XX0005 62C1505B0XX0006 62C2205B0XX0005 62C2205B0XX0006


VI 3 person 18 70 63C1505B0XX0005 63C1505B0XX0006 63C2205B0XX0005 63C2205B0XX0006
VI 4 person 18 70 64C1505B0XX0005 64C1505B0XX0006 64C2205B0XX0005 64C2205B0XX0006
VI 5 person 18 70 65C1505B0XX0005 65C1505B0XX0006 65C2205B0XX0005 65C2205B0XX0006
VI 6 person 18 70 66C1505B0XX0005 66C1505B0XX0006 66C2205B0XX0005 66C2205B0XX0006

VI 2 person 35 80 62C15H6D0XX0005 62C15H6D0XX0006 62C22H6D0XX0005 62C22H6D0XX0006


VI 3 person 35 80 63C15H6D0XX0005 63C15H6D0XX0006 63C22H6D0XX0005 63C22H6D0XX0006
VI 4 person 35 80 64C15H6D0XX0005 64C15H6D0XX0006 64C22H6D0XX0005 64C22H6D0XX0006
VI 5 person 35 80 65C15H6D0XX0005 65C15H6D0XX0006 65C22H6D0XX0005 65C22H6D0XX0006
VI 6 person 35 80 66C15H6D0XX0005 66C15H6D0XX0006 66C22H6D0XX0005 66C22H6D0XX0006

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 30 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Drger Aerospace PN Interchangeability - For information and AOG purpose only

Table 2i):
Type VI Passenger Oxygen Containers WITH PULLFLAG

Interchangeability to a longer duration of O2 supply is granted unconditionally.

CAUTION: Interchangeability to a shorter duration is permitted only under strict conditions, see section 3.7.4

Two way Two way

Container Number Lanyard Length / Tube 15 minutes O2 15 minutes O2 22 minutes O2 22 minutes O2


type of Masks with FLAG Length Supply Supply Supply Supply
(Inches) (Inches) 5th Evolution 6th Evolution 5th Evolution 6th Evolution

VI 2 person 18 / 30 70 62C1505Q0XX0005 62C1505Q0XX0006 62C2205Q0XX0005 62C2205Q0XX0006


VI 3 person 18 / 30 70 63C1505Q0XX0005 63C1505Q0XX0006 63C2205Q0XX0005 63C2205Q0XX0006
VI 4 person 18 / 30 70 64C1505Q0XX0005 64C1505Q0XX0006 64C2205Q0XX0005 64C2205Q0XX0006
VI 5 person 18 / 30 70 65C1505Q0XX0005 65C1505Q0XX0006 65C2205Q0XX0005 65C2205Q0XX0006
VI 6 person 18 / 30 70 66C1505Q0XX0005 66C1505Q0XX0006 66C2205Q0XX0005 66C2205Q0XX0006

VI 2 person 35 / 48 80 62C15H6N0XX0005 62C15H6N0XX0006 62C22H6N0XX0005 62C22H6N0XX0006


VI 3 person 35 / 48 80 63C15H6N0XX0005 63C15H6N0XX0006 63C22H6N0XX0005 63C22H6N0XX0006
VI 4 person 35 / 48 80 64C15H6N0XX0005 64C15H6N0XX0006 64C22H6N0XX0005 64C22H6N0XX0006
VI 5 person 35 / 48 80 65C15H6N0XX0005 65C15H6N0XX0006 65C22H6N0XX0005 65C22H6N0XX0006
VI 6 person 35 / 48 80 66C15H6N0XX0005 66C15H6N0XX0006 66C22H6N0XX0005 66C22H6N0XX0006

All part numbers listed on the same row are interchangeable, taking into account O2 supply duration (row means a single horizontal line of text)
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION: Two way interchangeability is permitted between containers with the same duration of O2 supply. Replacing a container by one with a longer duration of O2 supply is also permitted.
Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.7.4 are met.

SIL NUMBER: 35-007


PAGE: 31 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

3.8. CHEMICAL PASSENGER OXYGEN CONTAINER INTERCHANGEABILITY BETWEEN


VENDOR DRAEGER AND B/E AEROSPACE

Tables 3a) to 3d) detail the container interchangeability between vendors Drger Aerospace
and B/E Aerospace.

3.8.1 CONTAINER INTERCHANGEABILITY CONDITIONS

Interchangeability is possible unconditionally only if all following criteria are fulfilled (except for
A330/A340 aircraft as per above NOTE):
Container type is identical.
Door opening orientation is identical.
Lanyard length and tube length are identical.
Number of masks is identical or is HIGHER.
(for example PN AE5L43-XX may be replaced by PN 14C22L23XXX0003 but not by
12C22L23XXX0003).
Oxygen supply duration is identical or is HIGHER.
Drger Aerospace part numbers (if used) must end with design evolution code 0003
or 0004 or 0005 or 0006.

Interchangeability is possible WITH CONDITION if:


All criteria above mentioned are fulfilled except that:
Oxygen supply duration is LOWER.

CONDITION: The installation of 13 minutes generators in place of 15 minutes, or 15 minutes


generators in place of 22 minutes, or 13 minutes generators in place of 22 minutes implies that
the aircraft is operated in accordance with the lowest performance of the equipment installed
(i.e. 13 or 15 minutes performance). This is valid in any case if at least one generator or
container 13 or 15 minutes is installed at any location within the aircraft.

MANDATORY: The emergency descent profile indicated in the FCOM of the affected aircraft
must be replaced by a new descent profile adapted to the new performance.
ALSO the crew must be clearly informed of this temporary change.

Any of the above interchangeability (with or without condition) applies to AOG situations only.
Therefore it is required for the aircraft to recover its original configuration at the earliest
opportunity and within 500FH at the latest.

3.8.2 MIXABILITY OF COMPONENTS FROM DIFFERENT VENDORS

Mixability of components (sub-assemblies) between DRGER AEROSPACE and B/E Aerospace


containers is not possible due to design differences.

SIL NUMBER: 35-007


PAGE: 32 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER


Oxygen Container Interchangeability Between B/E Aerospace and Drger Aerospace
For AOG Purposes
Table 3a): Type I Containers Left-hand Units

Lanyard 10 Inches 24 Inches 40 Inches


Length
2 MASKS 3 MASKS 4 MASKS 2 MASKS 3 MASKS 4 MASKS 2 MASKS 3 MASKS 4 MASKS

AH5L32-XX AH5L33-XX AH5L34-XX AH5L42-XX AH5L43-XX AH5L44-XX N/A N/A N/A


Min
B/E
13

AJ5L32-XX AJ5L33-XX AJ5L34-XX AJ5L42-XX AJ5L43-XX AJ5L44-XX N/A N/A N/A

AE5L32-XX AE5L33-XX AE5L34-XX AE5L42-XX AE5L43-XX AE5L44-XX AE5L52-XX AE5L53-XX AE5L54-XX


AF5L32-XX AF5L33-XX AF5L34-XX AF5L42-XX AF5L43-XX AF5L44-XX AF5L52-XX AF5L53-XX AF5L54-XX
15 Mins
B/E

S1L122-XX S1L123-XX S1L124-XX S1L322-XX S1L323-XX S1L324-XX S1L642-XX S1L643-XX S1L644-XX


W1L122-XX W1L123-XX W1L124-XX W1L322-XX W1L323-XX W1L324-XX W1L642-XX W1L643-XX W1L644-XX
G1L122-XX G1L123-XX G1L124-XX G1L322-XX G1L323-XX G1L324-XX G1L642-XX G1L643-XX G1L644-XX
12C15L21XXX0003 13C15L21XXX0003 14C15L21XXX0003 12C15L23XXX0003 13C15L23XXX0003 14C15L23XXX0003 12C15L47XXX0003 13C15L47XXX0003 14C15L47XXX0003
15 Mins
Drger

12C15L212XXX0004 13C15L212XXX0004 14C15L212XXX0004 12C15L232XXX0004 13C15L232XXX0004 14C15L232XXX0004 12C15L474XXX0004 13C15L474XXX0004 14C15L474XXX0004


12C15L212XXX0005 13C15L212XXX0005 14C15L212XXX0005 12C15L232XXX0005 13C15L232XXX0005 14C15L232XXX0005 12C15L474XXX0005 13C15L474XXX0005 14C15L474XXX0003

AE6L32-XX AE6L33-XX AE6L34-XX AE6L42-XX AE6L43-XX AE6L44-XX AE6L52-XX AE6L53-XX AE6L54-XX


22 Mins

AF6L32-XX AF6L33-XX AF6L34-XX AF6L42-XX AF6L43-XX AF6L44-XX AF6L52-XX AF6L53-XX AF6L54-XX


B/E

AG5L32-XX AG5L33-XX N/A AG5L42-XX AG5L43-XX N/A N/A N/A N/A


E1L122-XX E1L123-XX E1L124-XX E1L322-XX E1L323-XX E1L324-XX E1L642-XX E1L643-XX E1L644-XX
12C22L21XXX0003 13C22L21XXX0003 14C22L21XXX0003 12C22L23XXX0003 13C22L23XXX0003 14C22L23XXX0003 12C22L47XXX0003 13C22L47XXX0003 14C22L47XXX0003
22 Mins
Drger

12C22L212XXX0004 13C22L212XXX0004 14C22L212XXX0004 12C22L232XXX0004 13C22L232XXX0004 14C22L232XXX0004 12C22L474XXX0004 13C22L474XXX0004 14C22L474XXX0004


12C22L212XXX0005 13C22L212XXX0005 14C22L212XXX0005 12C22L232XXX0005 13C22L232XXX0005 14C22L232XXX0005 12C22L474XXX0005 13C22L474XXX0005 14C22L474XXX0003

All part numbers listed down the same column are interchangeable, taking into account O2 supply duration. By column we mean a single vertical line of text.
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION:- Full two way interchangeability is permitted between containers with the same duration of O2 supply.(As indicated by the arrows) Replacing a container by one with a longer duration of O2
supply is also permitted. Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.8.1 are met.

SIL NUMBER: 35-007


PAGE: 33 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Oxygen Container Interchangeability Between B/E Aerospace and Drger Aerospace


For AOG Purposes
Table 3b): Type I Containers Right-hand Units

Lanyard 10 Inches 24 Inches 40 Inches


Length
2 MASKS 3 MASKS 4 MASKS 2 MASKS 3 MASKS 4 MASKS 2 MASKS 3 MASKS 4 MASKS

AH5R32-XX AH5R33-XX AH5R34-XX AH5R42-XX AH5R43-XX AH5R44-XX N/A N/A N/A


Min
B/E
13

AJ5R32-XX AJ5R33-XX AJ5R34-XX AJ5R42-XX AJ5R43-XX AJ5R44-XX N/A N/A N/A


AE5R32-XX AE5R33-XX AE5R34-XX AE5R42-XX AE5R43-XX AE5R44-XX AE5R52-XX AE5R53-XX AE5R54-XX
AF5R32-XX AF5R33-XX AF5R34-XX AF5R42-XX AF5R43-XX AF5R44-XX AF5R52-XX AF5R53-XX AF5R54-XX
15 Mins
B/E

S1R122-XX S1R123-XX S1R124-XX S1R322-XX S1R323-XX S1R324-XX S1R642-XX S1R643-XX S1R644-XX


W1R122-XX W1R123-XX W1R124-XX W1R322-XX W1R323-XX W1R324-XX W1R642-XX W1R643-XX W1R644-XX
G1R122-XX G1R123-XX G1R124-XX G1R322-XX G1R323-XX G1R324-XX G1R642-XX G1R643-XX G1R644-XX
12C15R21XXX0003 13C15R21XXX0003 14C15R21XXX0003 12C15R23XXX0003 13C15R23XXX0003 14C15R23XXX0003 12C15R47XXX0003 13C15R47XXX0003 14C15R47XXX0003
15 Mins
Drger

12C15R212XXX0004 13C15R212XXX0004 14C15R212XXX0004 12C15R232XXX0004 13C15R232XXX0004 14C15R232XXX0004 12C15R474XXX0004 13C15R474XXX0004 14C15R474XXX0004


12C15R212XXX0005 13C15R212XXX0005 14C15R212XXX0005 12C15R232XXX0005 13C15R232XXX0005 14C15R232XXX0005 12C15R474XXX0005 13C15R474XXX0005 14C15R474XXX0003
AE6R32-XX AE6R33-XX AE6R34-XX AE6R42-XX AE6R43-XX AE6R44-XX AE6R52-XX AE6R53-XX AE6R54-XX
22 Mins

AF6R32-XX AF6R33-XX AF6R34-XX AF6R42-XX AF6R43-XX AF6R44-XX AF6R52-XX AF6R53-XX AF6R54-XX


B/E

AG5R32-XX AG5R33-XX N/A AG5R42-XX AG5R43-XX N/A N/A N/A N/A


E1R122-XX E1R123-XX E1R124-XX E1R322-XX E1R323-XX E1R324-XX E1R642-XX E1R643-XX E1R644-XX
12C22R21XXX0003 13C22R21XXX0003 14C22R21XXX0003 12C22R23XXX0003 13C22R23XXX0003 14C22R23XXX0003 12C22R47XXX0003 13C22R47XXX0003 14C22R47XXX0003
22 Mins
Drger

12C22R212XXX0004 13C22R212XXX0004 14C22R212XXX0004 12C22R232XXX0004 13C22R232XXX0004 14C22R232XXX0004 12C22R474XXX0004 13C22R474XXX0004 14C22R474XXX0004


12C22R212XXX0005 13C22R212XXX0005 14C22R212XXX0005 12C22R232XXX0005 13C22R232XXX0005 14C22R232XXX0005 12C22R474XXX0005 13C22R474XXX0005 14C22R474XXX0003

All part numbers listed down the same column are interchangeable, taking into account O2 supply duration. By column we mean a single vertical line of text.
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION:- Full two way interchangeability is permitted between containers with the same duration of O2 supply.(As indicated by the arrows) Replacing a container by one with a longer duration of O2
supply is also permitted. Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.8.1 are met.

SIL NUMBER: 35-007


PAGE: 34 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Oxygen Container Interchangeability Between B/E Aerospace and Drger Aerospace


For AOG Purposes
Table 3c): Type II Containers
Interchangeability to a longer duration of O2 supply granted unconditionally.

Lanyard 19.5 Inches 10 Inches 19.5 Inches 27 Inches 40 Inches


Length
2 MASKS with PULL 2 MASKS 2 MASKS 2 MASKS 2 MASKS
FLAG

only permitted under strict conditions, see section 3.8.1


CAUTION:- Interchangeability to a shorter duration is
Mins
B/E
13

AH5702-XX AH5742-XX AH5722-XX AH5712-XX AH5732-XX

AE5702-XX AE5742-XX AE5722-XX AE5712-XX AE5732-XX


15 Mins
B/E

S2F212-XX S2N122-XX S2N212-XX S2N422-XX S2N632-XX

G2F212-XX G2N122-XX G2N212-XX G2N422-XX G2N632-XX

22C150150XXX0003 22C150210XXX0003 22C150120XXX0003 22C150240XXX0003 22C150370XXX0003


15 Mins
Drger

22C150150XXX0004 22C150210XXX0004 22C150120XXX0004 22C150240XXX0004 22C150370XXX0004

22C150150XXX0005 22C150210XXX0005 22C150120XXX0005 22C150240XXX0005 22C150370XXX0005

AE6702-XX AE6742-XX AE6722-XX AE6712-XX AE6732-XX


Mins
B/E
22

E2F212-XX E2N632-XX E2N212-XX E2N422-XX E2N422-XX

22C220150XXX0003 22C220210XXX0003 22C220120XXX0003 22C220240XXX0003 22C220370XXX0003


22 Mins
Drger

22C220150XXX0004 22C220210XXX0004 22C220120XXX0004 22C220240XXX0004 22C220370XXX0004

22C220150XXX0005 22C220210XXX0005 22C220120XXX0005 22C220240XXX0005 22C220370XXX0005

All part numbers listed down the same column are interchangeable, taking into account O2 supply duration. By column we mean a single vertical line of text.
CAUTION:- Full two way interchangeability is permitted between containers with the same duration of O2 supply.(As indicated by the arrows) Replacing a container by one with a longer duration of O2
supply is also permitted. Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.8.1 are met.

SIL NUMBER: 35-007


PAGE: 35 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

Oxygen Container Interchangeability Between B/E Aerospace and Drger Aerospace


For AOG Purposes
Table 3d): Type III Containers

Lanyard 27 Inches 38 Inches


Length
2 MASKS 3 MASKS 4 MASKS 5 MASKS 2 MASKS 3 MASKS 4 MASKS 5 MASKS

AH5H62-XX AH5H63-XX AH5H64-XX AH5H65-XX AH5H52-XX AH5H53-XX AH5H54-XX AH5H55-XX


Mins
B/E
13

AJ5H62-XX AJ5H63-XX AJ5H64-XX AJ5H65-XX AJ5H52-XX AJ5H53-XX AJ5H54-XX AJ5H55-XX


AE5H62-XX AE5H63-XX AE5H64-XX AE5H65-XX AE5H52-XX AE5H53-XX AE5H54-XX AE5H55-XX
AF5H62-XX AF5H63-XX AF5H64-XX AF5H65-XX AF5H52-XX AF5H53-XX AF5H54-XX AF5H55-XX
Mins
B/E

S3N432-XX S3N433-XX S3N434-XX S3N435-XX S3N542-XX S3N543-XX S3N544-XX S3N545-XX


15

W3N432-XX W3N433-XX W3N434-XX W3N435-XX W3N542-XX W3N543-XX W3N544-XX W3N545-XX


G3N432-XX G3N433-XX G3N434-XX G3N435-XX G3N542-XX G3N543-XX G3N544-XX G3N545-XX
32C150342XXX0003 33C150342XXX0003 34C150342XXX0003 35C150342XXX0003 32C150462XXX0003 33C150462XXX0003 34C150462XXX0003 35C150462XXX0003
Drger

Mins
15

32C150342XXX0004 33C150342XXX0004 34C150342XXX0004 35C150342XXX0004 32C150462XXX0004 33C150462XXX0004 34C150462XXX0004 35C150462XXX0004


32C150342XXX0005 33C150342XXX0005 34C150342XXX0005 35C150342XXX0005 32C150462XXX0005 33C150462XXX0005 34C150462XXX0005 35C150462XXX0005
AE6H62-XX AE6H63-XX AE6H64-XX N/A AE6H52-XX AE6H53-XX AE6H54-XX N/A
AF6H62-XX AF6H63-XX AF6H64-XX N/A AF6H52-XX AF6H53-XX AF6H54-XX N/A
Mins
B/E
22

AG6H62-XX AG6H63-XX AG6H64-XX N/A AG6H52-XX AG6H53-XX AG6H54-XX N/A


E3N432-XX E3N433-XX E3N434-XX E3N435-XX E3N542-XX E3N543-XX E3N544-XX E3N545-XX
32C220342XXX0003 33C220342XXX0003 34C220342XXX0003 35C220342XXX0003 32C220462XXX0003 33C220462XXX0003 34C220462XXX0003 35C220462XXX0003
Drger

Mins
22

32C220342XXX0004 33C220342XXX0004 34C220342XXX0004 35C220342XXX0004 32C220462XXX0004 33C220462XXX0004 34C220462XXX0004 35C220462XXX0004


32C220342XXX0005 33C220342XXX0005 34C220342XXX0005 35C220342XXX0005 32C220462XXX0005 33C220462XXX0005 34C220462XXX0005 35C220462XXX0005

All part numbers listed down the same column are interchangeable, taking into account O2 supply duration. By column we mean a single vertical line of text.
In addition installation of a container with INCREASED number of masks is also possible (installation of less masks is not acceptable).
CAUTION:- Full two way interchangeability is permitted between containers with the same duration of O2 supply.(As indicated by the arrows) Replacing a container by one with a longer duration of O2
supply is also permitted. Replacing a container by one with a shorter duration of O2 supply is only acceptable if conditions detailed in section 3.8.1 are met.

SIL NUMBER: 35-007


PAGE: 36 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006
AIRBUS

SERVICE INFORMATION LETTER

4. AIRBUS ACTION:

Not applicable.

5. MODIFICATION INFORMATION:

For permanent modification of the cabin emergency oxygen system contact Airbus UPGRADE
SERVICES (E-Mail: upgrade.services@airbus.com).

6. MATERIAL:

Not applicable.

7. PROCUREMENT:

Not applicable.

SIL NUMBER: 35-007


PAGE: 37 of 37
DATE: Feb 14/1995
REVISION: 03, Jul 19/2006