Professional Documents
Culture Documents
ISSN: 2352-9989
1
Dpartement dlectrotechnique ,Universit UDL de Sidi Bel Abbes ;Laborotoire IRECOM
Abstract. This paper present a comparative study between two control methods : classical regulator PID and
robust controller based on advanced frequency techniques H , applied on the automatic excitation control
system of synchronous machine (alternators) , to improve stability of a SMIB power system. The computer
simulation results (with test of robustness against machine parameters uncertainty), have proved that good
dynamic performances and more robustness with the robust H controller on comparison with using classical
PID regulator. Our present study was performed using a GUI realized under MATLAB in our work.
Keywords: synchronous machines powerful, automatic excitation control , classical regulator PID , robust
control , advanced frequency techniques H , stability an robustness , electric power system
Rsum. Cet article prsente une tude comparative entre deux mthodes de commande : Rgulateur classique
ralis en PID et un contrleur robuste bas sur les techniques frquentielles avances H, appliqus la
rgulation automatique dexcitation des machines synchrones puissants (turboalternateurs) pour lamlioration
de robustesse de stabilit dun systme lectro-nergtique (simple standard IEEE type SMIB). Les rsultats de
simulation (avec un test de robustesse vis--vis des variations paramtriques de la machine), montrent une
amlioration considrable des performances dynamiques et une grande robustesse de stabilit avec lutilisation
de contrleur robuste H en comparaison avec un rgulateur conventionnel type PID. Notre tude a t effectue
laide dun GUI quon a ralis sous logiciel MATLAB.
Mots cls: Gnrateurs synchrones puissants, control automatique dexcitation, AVR-PSS, rgulateur PID,
systme lectro-nergtique et stabilit, commande robuste H.
1. Introduction
une centrale de production dlectricit contient plusieurs machines synchrones (turbo-
2014 JARST. All rights reserved
alternateurs) qui sont conues transformer la puissance mcanique des turbines en puissance
lectrique(phase de production), cette dernire sera transmis par des lignes de transports, puis
distribues aux ventuels consommateurs (usage domestique ou industriels) . ces consommateurs
dnergie lectrique demandent toujours la continuit de service avec une stabilit du systme
de production, pour leur satisfaire les lectrotechniciens cherchent toujours des mthodes et des
techniques fiables fin dassurer une production dlectricit stable, de bonne qualit, continue, et
sans aucune interruption.
*
Corresponding author.
E-mail: jamelbel22@yahoo.fr (GHOURAF. D. E..).
Address: Laborotoire IRECOM , Univ. Sidi Bel Abbes BP 98, SBA, ALGERIE
58
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
Le problme de robustesse de stabilit est pos de faon srieuse pour garantir un bon
fonctionnement des Systmes Electro-Energtiques, et surmonter le problme des oscillations
lectromcaniques en amliorant lamortissement du systme (la stabilit) , pour ces fins des signaux
supplmentaires stabilisateurs sont introduits dans le systme dexcitation via son rgulateur de
tension. Ces signaux stabilisateurs vont produire des couples en phase avec la variation de vitesse du
gnrateur pour compenser le retard de phase introduit par le systme dexcitation. Les stabilisateurs
de puissance [1] (Power System Stabilizers, PSSs), grce leurs avantages en terme de cot
conomique et defficacit, sont les moyens habituels, non seulement pour liminer les effets ngatifs
des rgulateurs de tension, mais aussi pour amortir les oscillations lectromcaniques et assurer la
stabilit globale du systme .
Ces stabilisateurs conventionnels (raliss souvent en PI ou PID) ont pour inconvnient principal
[2] la mauvaise adaptation des changements des paramtres du systme et lors des variations
brusques des conditions de fonctionnement du systme commander (problmes incertains).
Pour assurer la stabilit du systme lectro-nergtique en prsence des diverses variations nous
utilisons les techniques de commande avances telles que : optimale, adaptative et robuste plutt que
celles classiques. Une des principales caractristiques actuellement exiges des rgulateurs est la
robustesse de stabilit, cest laptitude de maintenir la stabilit en prsence des variations
paramtriques du systme (ou aussi non-paramtriques), appel ainsi incertitudes ou problmes
incertains. Linvestigation des algorithmes de commande adaptative (Logique flou, rseau de
neurones) a t largement reporte. Rcemment, les algorithmes de commande optimale et robuste:
commande LQG, par mode de glissement, commande robuste H2 et H [3-5] ont t appliqus. Tous
ces algorithmes supposent la connaissance dun modle du systme ou des intervalles sur les
incertitudes.
Ufref
GS Xe T
AVR-PSS P
Excitatrice G
2014 JARST. All rightsreserved
Bus infini
Mesure
59
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
Les puissances d'excitation des alternateurs de forte puissance sont telles (plusieurs mgawatts)
qu'il est intressant d'utiliser la puissance mcanique disponible sur l'arbre pour fournir le courant
d'excitation. On utilise alors un systme d'excitation mont sur le mme arbre que le rotor de
l'alternateur. De plus, il est alors possible de supprimer les contacts glissants ncessaires
l'alimentation de l'excitation [1,2].
LAVR (Automatic Voltage Regulator) est un systme de rgulation de la tension dun gnrateur
synchrone puissant. Le systme AVR agit pour rguler cette tension par lintermdiaire de
lexcitatrice. Par ailleurs, Les stabilisateurs des systmes de puissance PSS, taient dvelopps pour
assister amortir les oscillations de la tension de sortie d'un alternateur [1,3]. Le schma synoptique
simplifie de systme dexcitation avec rgulateur AVR, PSS est donn par les figures 2 et 3.
60
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
Objet de commande
Uref GS
AVR+PSS Excitatrice
G
(AVR-FA)
f, f, u, u, if, if, P
BIM
UG
Contrleur robuste H
Ce modle fait un certain nombre dhypothses simplificatrices. Linduction dans lentrefer est
sinusodale, la saturation du circuit magntique, les pertes fer, les harmoniques dencoches et
despaces ne sont pas pris en compte dans la modlisation. En raison de la simplicit de la formulation
algbrique, ce type dapproche est bien adapt llaboration dalgorithmes de commande [1 ,6].
2014 JARST. All rightsreserved
61
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
''
X q
Iq
E d''
Ud
''
X d
Id
E q''
Uq
Id =
U q E q''
Iq =
(
U d E d'' )
( f ad )
If =
X ''
X q'' X sr
d
(1)
( 1d ad ) ( 2q aq ) ( 1q aq )
I 1d = I 2q = I 1q =
X srd X sr 2 q X sr1q
Xf ' X fd '
1 . Eq + 1 . E fq 1 .
X fq
E '
X sf X X sfd X X fd
E = '' ad ad sfq X (2)
=
'' aq
q
1 1 1 E d
+ + 1 1
+
X ad X sf X sfd X ad X sfq
''
q ( ''
d ) ;
ad = E + X Xs Id aq = E + X X s I q ''
d ( ''
q ) f = s ( R
0
f I f + U f 0 )dt 1d = s ( R
0
I
1d 1d ).dt
1q 2q
( R ).dt ( R ).dt
1q = s I = s I (3)
1q 1q 2q 2q 2q
0 0
s
d = ( s )dt , s = (4)
s
j d
(5)
M j
+M j+Me=0 =
M T avec M : moment d'inertie
j
dt
d Pe
+ = MT s + ( ad .I q aq .I d ) = M T ou T j s = M T - M e
j d d (6)
dt s Tj
dt dt
62
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
Concernant le stabilisateur PSS des efforts considrables ont taient dploys pour le
dveloppement de ce systmes. La fonction de base d'un systme stabilisateur de puissance PSS est de
moduler l'excitation du gnrateur synchrone puissant pour fournir un amortissement aux oscillations
[1,2 ,3].
VPSSmax
input V1
pTW V2 1+ pT1 V3
KPSS 1+ pTW 1+ pT2 VPSS
VPSSmax
P ,
p
ou
= mach 0
input = et (8)
I f = I f I f 0
et
U f U f U f 0
=
63
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
V 1
=V 2 + T 2V 2
. .
V 1 ;
T T 1 1
(9)
.
V V + T .
V = 2 V ;
3 2 3
2
T T 2 2
.
V . .
. input
V = V ; V =K
3
3
1 1 PSS
T W
0 0
V odq
= Pv abc
= 2 V
Sin
( ) + L I' + X
i q
(10)
( )
e odq e
cos i d
64
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
w z
Pa
u
y
B = [B 1 B ] 2
C (15)
C = C 1
2
D D
D = D 11 12
2014 JARST. All rightsreserved
21 D 22
P(s) Vrifie:
.
x ( t ) = Ax + B 1 w + B 2 u
z = C 1 x + D 11 w + D 12 u
y = C 2 x + D 21 w + D 22 u (16)
65
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
Avec l'tude de l'approche de la sensibilit mixte on peut construire le systme global suivant
(Figure 11):
W1
W2
G W3
W1 W1 .G
P11
=
0 W2 P12
P(s) = (17)
0 W3 .G P21 P22
1 G
G (s)= [ A , B ,C , D ]
G G G G (18)
(19)
W ( s ) = [ Aw , Bw , Cw , Dw ]
1 1 1 1 1
(20)
W ( s ) = [ Aw , Bw , Cw , Dw ]
2 2 2 2 2
W ( s ) = [ Aw , Bw , Cw , Dw ]
3 3 3 3 3
(21)
A B 1 B 2
P(s) = C D 1 11 D 12 (22)
C D D
2 21 22
Et encore :
66
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
AG 0 0 0 0 BG
BW 1 C G AW 1 0 0 BW 1 BW D 1 G
0 0 AW 0 0 BW
2 2
BW 3 C G 0 0 AW 0 BW D (23)
P( s) =
3 3 G
DW 3 C G CW 1 0 0 DW 1 DW D
1 G
0 0 CW 2 0 0 DW 2
DW 3 C G 0 0 CW 3 0 DW D3 G
C 0 0 0 1 D
G
u1 P11 P12 z1
u2 P21 P22 z2
Le problme standard de la commande H (problme de petit gain) est effectue par la vrification
de 1'ingalit de norme infinie suivante :
T z 1u 1
= sup( max (T z 1u 1 ( j )) (24)
1
2014 JARST. All rightsreserved
W S 1
Tz1u1 =W R
1 (25)
2
1
WT 3
O :
1 (26)
W ( j) et (T ( j)) W ( j)
1 3
(s( j))
67
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
S : Sensibilit
T : Sensibilit complmentaire
W1, 2, 3:les fonctions des pondrations
: La valeur singulire maximale.
La synthse globale du rgulateur se ralise par la rsolution des deux matrices de HAMILTHON
H et J suivantes (qui correspondent aux deux quations algbriques de RICCATI) [3,10]:
L'existence du rgulateur robuste pour que si les conditions suivantes seront vrifies:
- H et J n'admettent pas des racines sur 1'axe imaginaire.
- X, Y (2 solutions d'quations de RICCATI), non ngatives
- ( XY ) <
2 : rayon spectral des solutions)
Si tout ces conditions sont vrifies, le rgulateur robuste a pour forme :
(27)
K ( S ) = F [( SI A ) 1 ]Z L
Ou : (28)
A = A + 2 B1 B1T X + B 2 F + Z L C 2
F = B 2T X ; (29)
L = Y C 2T ; Z = ( I n 2 Y X ) 1 (30)
La rsolution du problme de commande (standard et/ou optimale) dfini par les relations (24) et
(27) est propose comme suit [10, 11]:
1. Calcule du rgime permanent tabli (RP) ;
2014 JARST. All rightsreserved
68
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
4. Vrifier si toutes les conditions aux rangs des matrices sont satisfaire, si non on change dans la
structure des fonctions des pondrations ;
5. Choix d'une grande valeur de (niveau doptimisation) ;
6. Rsolution des deux quations de RICCATI dfinies par les deux matrices de HAMILTHON H et J
;
7. Si toutes les conditions sont vrifies on fait diminuer la valeur de , si non on fait augment , et en
refaire les tapes 4 a 5 jusqu' au l'obtention d'une solution optimale satisfaisante (une valeur optimale
min ) ;
8. Rduction de l'ordre du rgulateur si ncessaire (dans le langage RCT on utilise la commande
'Schbal par exemple) ;
9. Par l'obtention des valeurs optimales et deux solutions d'quations de RICCATI on obtient la
structure du rgulateur H ainsi que les racines de la boucle ferme avec le rgulateur robuste ;
10. Les paramtres du contrleur robuste H sous forme linaire 'LTI (SS espace d'tat, TF fonction de
transfert ou ZPK zros - ples - gains), seront transfrs de l'espace de travail (work space) vers le
milieu Simulink (block LTI-system);
11. La mise en marche du sous-systme 'simulation' et la ralisation de l'tude de la stabilit et la
robustesse du systme lectro-nergtique sous diffrents conditions de fonctionnements.
L'algorithme de synthse du contrleur dexcitation robuste H propos dans ce travail est clairement
schmatis par l'organigramme de la figure 13
2014 JARST. All rightsreserved
69
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
SIMULINK - MA TLAB
REDUCTION
Phase synthse
Reduction du rgulateur
[g ]
Goto 10
delta ] [Uq ] Cliques deux fois ci-dessous pour
[Pe ]
Step visualiser les courbes et les
From 2 Goto 2
[eug ] Goto 11
[delta
parametres dssires
[Uq ]
From 19
Goto 9
From 14
delta ] [DUf ] [Id ] [Id ] [Ud ]
If g TBB 500
Ug
100 Constant 4 [eif ]
Constant 3 PEM TBB 720
Gain 1 [If ] Goto 8
[Ug ] Dot Product erreur %
From 16 Pe TBB 720
From 1 1
2014 JARST. All rightsreserved
u
Math Ug la tension Ug TBB 1000
Function
Clock1 From 17 From 3 From 4 From 5 From 6 From 8 From 10 From 9 Constant 5 [eug ] Ug TBB 1000
[g ] [Ug ] [Pe ] [delta ] [G200 ] [G500 ] [G 720 ] [G1000 ] Goto 13
[Ug ]
From 20
g1
To Workspace y
70
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
20 20
40 40
60 60
80 80
100 100
120 120
0.98
0.96
0.94 1.02
0 2 4 6 8
100
1
0.98
0 2 4 6 8
1
1.02
0.98
1
0.96
0 2 4 6 8 0.98
0.96
0 1 2 3 4 5 6 7 8
71
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
PSS-
Q BO PSS BO PSS PSS-H
H
De lanalyse des rsultats trouvs dans les tableaux impairs on peut constater ce qui suit:
Le rgime le plus critique qui influe sur le systme est le rgime sous excit (cas plus dfavorable)
pour les diffrentes configurations.
72
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
Concernant les rgulateurs PSS et PSS-H nous remarquons que le systme est plus stable dans
tous les rgimes et avec tous types des lignes de transmission, on a des amliorations considrables
des performances dynamiques (augmentation de la prcision) du systme avec rgulation en
comparaison avec celui en boucle ouverte.
On remarque ainsi que le contrleur robuste PSS-H apportent beaucoup plus damliorations de
ces performances, par rapport lutilisation du rgulateur PSS seul. Daprs ces tableaux on a vrifi
les conditions de stabilit et damlioration des performances dynamiques du systme command avec
les contrleurs robuste PSS-H.
4.3.1 Etude de stabilit
Pour tudier le comportement dynamique de notre systme en rgime perturb (amortissement
doscillations lectromcaniques des paramtres de la machine synchrone), Les diffrents modles
(avec et sans rglage dexcitation) ont ts raliss sous MATLAB/SIMULINK.
Les courbes obtenues (16 et 17) nous donnent respectivement : la variation de vitesse en terme de
glissement () ; Langle interne delta du GSP entre la tension et la FEM ; La puissance
lectromagntique (Pe); La tension terminal du GSP (Ug).
0.99
1.1
0.985
Pem
Ug
1.05
0.98
1
0.975
0.95
0.97
0.965 0.9
0.96 0.85
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
le temps en sec le temps en sec
-3
la courbe de glissment Delta
x 10
3 2
BO BO
AVR AVR
1.95
2 PSS PSS
1.9
1
1.85
Delta
0
g
1.8
-1
1.75
-2 1.7
-3 1.65
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
le temps en sec le temps en sec
2014 JARST. All rightsreserved
73
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
-3 la courbe de delta
x 10 la courbe de glissment
3 1.6
BO BO
PSS PSS
2 PSS-Hinf PSS-Hinf
1.55
1
1.5
delta
0
g
1.45
-1
1.4
-2
-3 1.35
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
le temps en sec le temps en sec
1.02
1.15
1.01
Pem
Ug
1.1 1
0.99
1.05
0.98
1
0.97
0.95 0.96
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
le temps en sec le temps en sec
supposant cette fois ci que les paramtres lectriques sont connus (constants).
Le temps de la simulation est valu cette fois ci 8 secondes.
Nous prsentons dans lA figure 18 (Pour les incertitudes lectriques) et la figure 19 (Pour les
incertitudes mcaniques), la rponse des grandeurs lectriques et mcaniques de la machine
synchrone, vis--vis ces variations paramtriques (lectriques et mcaniques) linstant t = 4 s, pour
les diffrents types des GSP utiliss et sous plusieurs modes et conditions de fonctionnements du SEE
(Rgimes / configurations).
74
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
0.99
la puissance lctromagnitique
1.05
0.98
la tension statorique
1
0.97 PSS
PSS-Hinf
0.96 0.95
0.95
0.9
0.94
0.85
0.93
0.92 0.8
0 1 2 3 4 5 6 0 1 2 3 4 5 6
le temp le temp en sec
-4 la courbe de l angle de charge delta
x 10 la courbe de glissment
20 1.24
PSS PSS
PSS-Hinf 1.22 PSS-Hinf
15
1.2
10 1.18
glissment
delta
1.16
5
1.14
1.12
0
1.1
-5
0 1 2 3 4 5 6 1.08
0 1 2 3 4 5 6
le temp en sec
le temp en sec
1.005
la tension statorique
0.95
0.9
0.995
0.85
0.99
0.985 0.8
0 1 2 3 4 5 6 0 1 2 3 4 5 6
le temp le temp en sec
-4
x 10 la courbe de glissment
la courbe de l angle de charge delta
14
1.24
PSS
PSS
12 PSS-Hinf
1.22 PSS-Hinf
10
1.2
8
6 1.18
glissment
delta
4
1.16
2
1.14
0
1.12
-2
-4 1.1
2014 JARST. All rightsreserved
-6
0 1 2 3 4 5 6 1.08
0 1 2 3 4 5 6
le temp en sec
le temp en sec
Figure 19. Fonctionnement en rgime sous excit du TBB1000 raccord une ligne
longue en BF avec PSS et PSS- H
75
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
Daprs les rsultats obtenus on peut constater quune trs grande robustesse de stabilit de notre
systme, vis--vis ces variations paramtriques (lectrique et mcaniques) se manifeste avec
lutilisation du contrleur dexcitation PSS-H.
Dans certaines situations critiques (rgime de fonctionnement sous-excit), ce contrleur est plus
robuste, il amliore considrablement son efficacit pendant ces priodes de fonctionnent trs
difficiles de la station lectrique, pour supporter par exemple des coupures de courants et assure la
continue de service du SEE universel.
5. Conclusion :
Dans ce travail, on sest intress ltude des systmes de rgulation et de contrle robuste
dexcitation des gnrateurs synchrones puissants, pour lamlioration des performances et de la
robustesse de stabilit dun systme lectro nergtique. La synthse de ces contrleurs robustes, est
base sur les techniques doptimisation H utilisant les mthodes frquentielles avances de la
commande automatique moderne. Ces contrleurs dexcitation sont capables de maintenir des
meilleures performances dynamiques et de garantir la robustesse de stabilit du systme tudi face
des perturbations y compris incertains (incertitudes sur le systme), sous diffrents rgimes de
fonctionnements et configurations des rseaux.
6. Rfrences:
[1] P. KUNDUR, "Definition and Classification of power System Stability", Draft 2, 14 January,2002
[2] P.M. ANDERSON, A. A. FOUAD "Power System control and Stability", IEE Press, 1991.
[3] N. A. LEHTOMAKI, N. R. SANDELL, and M.ATHANS, \ Robustness results in linear quadratic Gaussian based multi
variable control design," IEEE Trans. On Automatic Control
[4] K. GLOVER, J.C. DOYLE, P.P. KHARGONEKAR, B.A. Francis "State-space solutions to standard H2 and H control
problems", IEEE Trans. on A.C., 1989, vol.34, N 8,834-847.
[5] Zhou K., Doyle J.C., Glover K. "Robust and optimal control. Englewood Cliffs", NJ: Prentice Hall, 1996
[6] S. V. SMOLOVIK "Mthodes de modlisation mathmatique des processus transitoires des gnrateurs synchrones plus
usuels et non traditionnels dans les systmes lectro -nergtiques"Thse doctorat d'tat, Institut polytechnique de
Leningrad, 1988 (traduit du Russe).
[7] GHOURAF.D.E "Exploitation des techniques frquentielles avances dans le contrle automatique dexcitation des
machines synchrones" mmoire Magister ETT, op. convertisseur lectromcanique, Dept. ETT, universit SBA, 2009-20110
[8] LA. GROUZDEV, A.A. STARODEBSEV, S.M. OUSTINOV "Conditions d'application des meilleurs amortissements des
2014 JARST. All rightsreserved
processus transitoires dans les systmes nergtiques avec optimisation numrique des paramtres du rgulateur AVR-FA"
Energie -1990-Nll-pp.21-25 (traduit du russe).
[9] R. Asgharian "Asymptomatic approach to performance weights slection in design of robust HPSS using geneSc
algorithms", IEEE trans. on EC, vol 11, No 21, September 1996, pp.111-117
[10] : Introduction `a la commande multi variable des systmes : mthodes de synthse frquentielle Hinf .Cours de 3A
Instru Auto de lENSI de Caen G. Scorletti Maitre de confrences `al Universit de Caen LAP, ISMRA
[11] G. DUC, Robustesse des Systmes Linaires Multi variables, Ecole Suprieure d'Electricit, 1994.
76
Ghouraf D. E. et al., Journal of Advanced Research in Science and Technology, 2014, 1(2), 58-77.
7. Annexes
Paramtres des gnrateurs synchrones puissants tudis
Paramtres TBB200 TBB500 BBC720 TBB1000 Units de Notations
mesures
77