Professional Documents
Culture Documents
Contents
FAS Controller Models and Compatible Shelves Page 1 - 3
SolidFire Page 19
3u FAS8020
By exception only
2u
FAS2620, FAS2650
DS4486 not
supported
4x6 Gbps
By exception only SAS/SATA/SSD DS2246 12 Gbps DS224C
Disk
SAS/SSD Disk DS14mk4, DS14mk2AT
[FC Attached Shelves]
System Shelf
FAS Matrix
System and Matrix
Shelf Identification v9.2a
and Identification v19.1
FAS Controller Models and Compatible Shelves
Controller Models and Compatible Shelves (2 of 3) Page 2 of 23
(Continued on Next Page>> )
DS14 FC Attached Shelf Models SAS Attached Shelf Models SAS Attached Shelf Models
1,2,4 Gbps SAS/SATA/ SATA/NL-SAS/
White Area - Top Shelves FC Disk SSD, MDC* SSD Disk
BLUE Area- BOTTOM Shelves Disk
DS212C
DS14mk4 Gray Color
DS4243/4246 and DS4486*
6u
V-FAS62x0, N7X50T, SA620
3u
V-FAS32x0, SA320
2u FAS2520, FAS2552
4u
These have internal SAS disks
FAS2554
DS4486 not
supported
2u FAS2240-2, FAS2220
These have internal SAS disks
4u FAS2240-4
3u V-FAS30x0, SA300
FAS3040/70 only
[A1-A5, A7-A11]
FAN 1 FAN 2 FAN 3
[B1-B5, B7-B11]
FAN MODULES
B1 B2 B3
10 I/O slots
10 I/O slots
A2 B2
A B P A P P
S S S A (Each
B3 1 Controller
A3 1 B 2
has its own
P System
S B
(Each Controller has its own System Serial Number) Serial
2
PS-1 PS-2 PS-3 PS-4 Number)
PSU-1 PSU-2 PSU-1 PSU-2 (Each Controller has its own System Serial Number)
FAS System Shelf Matrix and Identification v19.1 Page 5 of 23
Controller Models (2 of 3)
(Continued on Next Page>> )
FAS2552 FAS2520 FAS2220, FAS2240-2, N3220
Bezel Removed Bezel Removed Bezel Removed
0 1 2 3
2u 2u 4 5 6 7 FAS2220
8 9 10 11
0 1 2 3
0 Left to Right Disk Numbering 23 2u 4 5 6 7
8 9 10 11 2u FAS2240-2
(Each Controller has its own System Serial Number) (Each Controller has its own System Serial Number) 0 Left to Right Disk Numbering 23
(Each Controller has its own System Serial Number)
A B A B
PSU-2
A B
PSU-1 PSU-1 PSU-2
PSU-1 PSU-2
Rear View of a FAS2220 is similar to FAS2240-2
FAS2050, SA200, N3600 FAS2020, N3300, FAS2040, N3400 FAS30x0, V30x0, SA300, N5x00,
VTL300, 600, 700, 1200, 1400
Power Power
4u 0 1 2 3
Fault 2u 4 5 6 7 Fault
FAN-1
8 9 10 11 PCM A LCD Moddule (hot pluggable)
PCM A
PCM B
PCM B
3u
A FAN-2
2020
B
PSU-1 PSU-2 System
A PSU-1 PSU-2 Serial
A Number
PSU-2
B on front
2040 B
(Each Controller has its own System Serial Number) (Each PCM (Processor Controller Module) has its own System Serial Number)
PSU-1
FAS System Shelf Matrix and Identification v19.1
Controller Models (3 of 3) Page 6 of 23
3u
PSU-1 PSU-2
CPU Modules A, B
(Each FAS270 CPU Module has it's own System Serial Number)
FAS System Shelf Matrix and Identification v19.1
Controller Storage Shelves (1 of 3) Page 7 of 23
(Continued on Next Page>> )
DS14 14 Bay Shelf DS4243/DS4246 24 Bay Shelf DS2246 24 Bay Shelf
14 Drive Fibre-Channel driven Shelf DS4243/DS4246: 24 Drive SAS driven Shelf 24 Drive Single-Attached-SCSI driven Shelf
3u
13 0 4u 2u
Note: Right to Left Disk Numbering
Rear View 0 23
Note: Left to Right Disk Numbering
Note: Left to Right Disk Numbering
PSU-1 PSU-2 Shelf ID and LEDS
Shelf ID and LEDS
PSU-1 PSU-2
DS14 Disk Shelf
* LRC or ESH Shelf Module DS14Mk2, Mk4 Disk Shelf
* Fibre Channel Only Drives PSU-3 PSU-4
* Mk2: ESH2 Shelf Module
* No Gb Switch (1 Gb Only) * MK4: ESH4 Shelf Module
* Fibre Channel Only Drives PSU-1
PSU-1 and PSU-4 only if SATA Disks; PSU-2
DS14Mk2-AT Disk Shelf * Mk2: 1-2 Gb Switch, shown
Add PSU-2 and PSU-3 if SAS Disk
* AT-FC, FC2 or FCX Shelf Module * Mk4: 1-2-4 Gb Speed Sw not
* ATA Drives Only shown
* No Gb switch on-AT model
* Longer shelf than FC version
Shelf Modules Shelf Modules
ACP Data ACP Data Data ACP Data Data
Ethernet SAS Ethernet SAS HD MINI-SAS Ethernet SAS HD MINI-SAS
Shelf Modules
- DS14 Shelves support 2 families of shelf modules depending on IOM3 IOM6 IOM12 IOM6 IOM12
the disk type in the shelf: Fibre Channel (FC) or SATA. - IOM3 is 3Gb; IOM6 is 6Gb; IOM 12 is 12 Gb - IOM6 is 6Gb; IOM 12 is 12 Gb
- Shelf Model with Shelf Module Progression - The 24 bay DS4243 uses the IOM3/IOM6/IOM12 - The 24 bay DS4246 uses the IOM6/IOM12
FC Modules: DS14: LRC, ESH; Mk2:ESH2; Mk4: ESH4 - The 24 bay DS4246 uses the IOM6/IOM12 - IOM6 Left Side is an Ethernet connection, Alternate
SATA Modules: Mk2-AT: AT-FC, AT-FC2, AT-FC - IOM3/IOM6 Left Side is an Ethernet connection, Alternate Control Patch (ACP) for out-of-band management
Control Patch (ACP) for out-of-band management - OM6 Right Side are the SAS Data Connections
- Legacy modules have a "term" switch for loop termination, - IOM3/IOM6 Right Side are the SAS Data Connections - IOM12 Left & Right Side are the SAS Data Connections (HD MINI-SAS)
newer modules auto-terminate - IOM12 Left & Right Side are the SAS Data Connections (HD MINI-SAS) - For IOM6, all connectors are labeled as circle and square,
- Newest modules are gray in color, original was silver, - For IOM3/IOM6, all connectors are labeled as circle and square, Daisy chain: circle <> square or square <> circle
Daisy chain: circle <> square or square <> circle
FAS System Shelf Matrix and Identification v19.1 Page 8 of 23
Controller Storage Shelves (2 of 3)
(Continued on Next Page>> )
DS4486 24 Bay Shelf DS212C 12 Bay Shelf DS224C 24 Bay Shelf
DS4486: 48 Drives using Multi-Disk Carrier DS212C: 12 Drive SAS driven Shelf DS224C: 24 Drive SAS driven Shelf
(MDC) which has 2 drives per bay
Embossed with dual
drive sign
4u 0 1 2 3
2u 2u
4 5 6 7
8 9 10 11
Note: Left to Right Disk Numbering Note: Left to Right Disk Numbering
Note: Left to Right Disk Numbering Shelf ID and LEDS Shelf ID and LEDS
PSU-1 PSU-2
PSU-3 PSU-4
PSU-1 PSU-2 PSU-1 PSU-2
All 4 PSUs are used. Each PSU contains
voltage and temperature sensors, as well
as fans.
- The 12 bay DS212C uses the IOM12 which is 12Gb - The 24 bay DS224C uses the IOM12 which is 12Gb
- IOM12 Left & Right Side are the SAS Data Connections - IOM12 Left & Right Side are the SAS Data Connections
- The 24 bay DS4486 uses the IOM6 which is 6Gb
- IOM SAS Attention & Link LED provides the status of each SAS port. - IOM SAS Attention & Link LED provides the status of each SAS port.
- IOM6 Left Side is an Ethernet connection, Alternate
Control Patch (ACP) for out-of-band management
- IOM6 Right Side are the SAS Data Connections
FAS System Shelf Matrix and Identification v19.1
Controller Storage Shelves (3 of 3) Page 9 of 23
Drawer ID
values are 4u
1 (top)
to
5 (bottom)
Shelf ID
and
LEDS
IOM12
PSUs
AFF systems are built on the AFF systems are built on the
Model Model
Badge FAS8000 hardware and the FAS8000 hardware and the
Badge
FRUs are similar. FRUs are similar.
Rear View
6u
3u A1 A2 A3
3u B1 B2 B3
FAN-1 FAN-2 FAN-3
P
A S A (Each
PSU-1 PSU-2 1 Controller
B has its own
P System
B
S Serial
(Each Controller has its own 2 Number)
System Serial Number)
AFF (All Flash FAS) System Shelf Matrix and Identification v19.1 Page 11 of 23
Controllers and Storage Shelves (2 of 3)
(Continued on Next Page>> )
AFF A200 AFF A300
Model Model
Badge Badge AFF systems are built on
AFF systems are built on the FAS8200 hardware
the FAS2650 hardware
2u 3u
2u
3u FAN 1 FAN 2 FAN 3
0 Left to Right Disk Numbering 23
hardware 4u
A2 B2
IO Slots IO Slots B
A1-A5, B1-B6, PSU plug into Controller
A7-A11 A B B7-B11
(Each Controller has
its own System
Serial Number)
2u
PSU-1 PSU-2
E-Controllers
RED Ports are for Host Connects
Green Ports are for Shelf Expansion
E2600
Optional Host E2612 E2624 E2660
Int, Card Here
E2700
E-Controllers
RED Ports are for Host Connects
Green Ports are for Shelf Expansion
E2800
Optional Host
E2812 E2824 E2860
Int, Card Here
E-Series System Shelf Matrix and Identification v19.1 Page 14 of 23
Controllers (1 of 2)
(Continued on Next Page>> )
E2600 Controller in 2u Shelf E2700 Controller in 2u Shelf E2800 Controller in 2u Shelf
Controller Canister A Empty Controller Canister B Controller Canister A Controller Canister B Controller Canister A Controller Canister B
(Slot-1) (Slot-2) (Slot-1) (Slot-2) (Slot-1) (Slot-2)
Power Fan Canister Power Fan Canister Power Fan Canister Power Fan Canister Power Fan Canister
Power Fan Canister
(PSU-1) (PSU-2) (PSU-1) (PSU-2) (PSU-2)
Mini-USB (PSU-1)
Mini-USB
Connector (2) 16Gb FC/ 10Gb Connector
Console Dual ethernet (2) 12Gb SAS host (Serial Interface) 12Gb SAS drive iSCSI base host Dual ethernet (Serial Interface) 12Gb SAS drive
(2) 6Gb SAS host 6Gb SAS drive
Mini-DIN Dual ethernet connections interface ports expansion port interface ports connections expansion port
connections interface ports expansion port
E2624 Controller Canister with no optional Host E2724 Controller Canister with no optional Host E2812 Controller Canister with no optional
Interface card (HIC) Interface card (HIC) Host Interface Card (HIC)
"HIC options shown below " "HIC options shown below " "HIC options shown below "
E2600 Host Interface Card (HIC) Options E2700 Host Interface Card (HIC) Options E2800 Host Interface Card Options
P1 P2
LNK LNK
0c 0d 0e 0f
P1 P2
LNK LNK
EXP1 EXP2
P1 P2
LNK LNK
e0c e0d
EXP1 EXP2
Power Fan Canister Power Fan Canister Power Fan Canister Power Fan Canister
(PSU-1) (PSU-2) (PSU-1) (PSU-2)
Left Fan Canister Power Canisters
(Fan-1) Controller Canister B
(Slot-2) Console Dual ethernet (2) 6Gb SAS host Console Dual ethernet (2) 6Gb SAS host Console
Mini-USB connections interface ports Mini-USB connections interface ports Mini-USB
E5400 / EF540 Host Interface Card Options E5500 / EF550 Host Interface Card (HIC) E5600 / EF560 Host Interface Card (HIC)
Fibre channel / SAS Host Cards SAS Host Cards IB host card 2-port 56Gb/s IB
Dual/ Quad 8Gb FC ports Quad 6Gb SAS ports, see Quad 6-Gb SAS ports shown)
Quad shown 2600 HICs for picture
Page 16 of 23
Embedded PORTS HIC (Host Interface Card) OPTIONS
Controller Model (Can be Host or Shelf Expansion) (HIC Ports are always for Host Connections)
Dual 6Gb SAS Host Option
Two GbE OOB Mgmt ports Quad 8Gb FC Host Option
E26xx Dual 6Gb SAS Host Ports Quad 1GbE iSCSI Host Option
One 6Gb SAS Shelf Expansion
Dual 10GbE iSCSI Host Option
Two GbE OOB Mgmt ports Dual/Quad- port 16Gb FC / 10 Gb iSCSI Host Option
E28xx Dual 16Gb FC / 10Gb iSCSI Host Ports Dual-port 10Gb iSCSI copper RJ45 Host Option
One 12Gb SAS Shelf Expansion Dual/Quad 12Gb SAS Host Option
Rear View of a DE5600 shelf with two ESMs Rear View of a DE1600 shelf with one controller
Disks 10-12 Note: Expansion shelves use Expansion Shelf Modules (ESMs), Note: Expansion shelves use Expansion Shelf Modules (ESMs) ,
Systems use Controller Canisters Systems use Controller Canisters
Drive Fault LEDs:3-LEDs in 4 groups Controller
ESM A Shown ESM B Shown
Drive Drawer Status Service Action Required AMBER LED Canister A
Expansion Port Conector Expansion Port Conector Expansion Port Conector
Drive Drawer Status Service Action Allowed BLUE LED
Left Power Fan Canister Right Power Fan Canister Left Power Fan Canister Right Power Fan Canister
(PSU-1) (PSU-2) (PSU-1)
Standby LED Input AC Power LED Standby LED Input AC Power LED
Standby LED Input AC Power LED Output DC Power LED Power Service Action Required LED Output DC Power LED Power Service Action Required LED
Output DC Power LED Power Service Action Required LED
Power Service Action Allowed LED Power Service Action Allowed LED
Power Service Action Allowed LED
E-Series System Shelf Matrix and Identification v19.1
E-Series Storage Shelves (2 of 2)
Page 18 of 23
Output DC Power LED Attention LED Output DC Power LED Attention LED
Node 4
1 3 5 7 9
Top to Bottom Disk Numbering
Power Button
PSU-1 PSU-2
PSU-1 PSU-2
6u
4u
AltaVault AltaVault AVA400 DS4246 Shelf
4u
StorageGrid
SG5660 2u
SG5612
4u
6u P
A1 A2 A3 S A
USB Socket
0 1 2 3 2u FAN Modules 1
Power Active 4 5 6 7
Unit Fault 8 9 10 11
ID LED P
On/Off Switch S
System Reset 2
ID LED Switch Rear View
System Serial Number (SSN)
Rear
View
Expansion Shelf AVA10S (DS4246 Shelf)
PSUs
0 1 2 3
4 7
Expansion Shelf 8 11
12 15
Mute Button 4u 16 19
System Power
0 1 2 3 2u 20 23
Module Fault 4 5 6 7
Logical Fault 8 9 10 11
Shelf ID and LEDS
LED Display
"A" IOM6 "B" IOM6
PSU 1 PSU 2
PSU-1 PSU-2
Rear
View PSU-3 PSU-4
Rear View
- Maximum upto 5 shelves can be added - Supports upto three disk shelves
Other NetApp Systems Shelf Matrix and Identification v19.1
(SteelStore, AltaVault, StorageGrid, EVO Rail) 3 of 4 Page 22 of 23
(Continued on Next Page>> )
StorageGrid Webscale (SG5660) StorageGrid Webscale (SG5612)
SG5660 SG5612
60 Drive Shelf (DE6600) : (5) 12-drive drawers.
12 Drive Shelf : 12-drives
4u
1 4 2u
5 8
9 12
Disks 10-12
Rear
View
Drive Fault LEDs:3-LEDs in 4 groups
Drive Drawer Status Service Action Required AMBER LED
Drive Drawer Status Service Action Allowed BLUE LED
Rear
View
"FAS2552A-EVO"
NetApp FAS2552 system with 2-node cluster.
FRU replacements Supported by NetApp.
2u
A B
PSU-1 PSU-2