GENERAL NOTES
A. DO NOT SCALE THE DRAWINGS.
C. UNLESS OTHERWISE INDICATED, PLAN DIMENSIONS ARE TO COLUMN GRID ON CENTERLINES, NOMINAL
SURFACE OF MASONRY, FACE OF STUDS AND FACE OF CONCRETE WALLS.
D. "FLOOR LINE" REFERS TO TOP OF FINISHED FLOORING FOR DEPRESSED FLOORS AND CURBS, SEE
STRUCTURAL DRAWINGS OR DETAILS.
E. REPETITIVE FEATURES ARE NOT DRAWN IN THEIR ENTIRETY AND SHALL BE COMPLETELY PROVIDED AS IF
DRAWN IN FULL.
G. WHERE A DOOR IS LOCATED NEAR CORNER OF ROOM AND IS NOT LOCATED BY DIMENSION ON PLAN OR
DETAILS, DIMENSION SHALL BE 76mm FROM FACE OF STUD (WALL) TO FACE OF ROUGH OPENING.
DIMENSION SHALL BE 153mm FROM FACE OF WALL TO EDGE OF ROUGH OPENING AT CONCRETE WALLS.
H. AT SECURITY WALLS (IF ANY), FULL HEIGHT PARTITIONS SHALL BE SEALED BOTH SIDES
I. ALL DIMENSIONS OF WINDOWS IN ELEVATIONS ARE NOMINAL SIZES OF WINDOW FRAMES UNLESS
OTHERWISE NOTED. ALL DOOR SIZES INDICATE CLEAR OPENING BETWEEN DOOR JAMB.
L. UNLESS OTHERWISE NOTED ALL STUD WALL FRAMES, ROOF FRAMING AND BASE FRAMING WILL BE
Sheet List CONSTRUCTED WITH STANDARD SPACING OR MEMBER SIZES TO MANUFACTURER OR ENGINEER DETAILS.
FOR RETROFITTING OF ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER FURRING, CURBS, ANCHORS
Sheet Number Sheet Name
AND INSERTS NO BASES OR BLOCKING IS PROVIDED UNLESS REQUESTED BY THE CUSTOMER PRIOR
A-01 Proposed Floor Plan CONSTRUCTION STAGE.
A-02 Proposed Elevations
S-01 Base Frame Details M. ALL INTERIOR METAL STUD WALLS SHALL BE CONSTRUCTED WITH 90mm WALL STUDS UNLESS
S-03 Connection Details OTHERWISE NOTED
A-03 Typical Section N. ALL DIMENSIONS IN PRELIMINARY STAGE ARE APPROXIMATE AND DO NOT CONSIDER CONSTRUCTION
S-02 Floor Joists Setout TOLERANCE AND ADEQUACY. FIXED DIMENSIONS WILL BE DETERMINED AFTER THE COMPLETION OF
S-04 Wall Framing Setout STRUCTURAL COMPUTATIONS AND CERTIFICATION OF DESIGN. IN GENERAL THAT MIGHT EFFECT:
S-05 Wall Framing STRUCTURAL BASE FLOOR THICKNESS AND JOIST SPACING, ROOF AND CEILING FRAMING THICKNESS
PURLINS SPACING, WALL THICKNESS AND STUD SPACING, BULKHEADS HEIGHTS, OPENINGS LOCATION AND
S-06 Internal Wall Frames
SPACING.
S-07 Roof Framing
A-05 Internal Elevations - Storage O. THE CONTRACT (OR QUOTATION OFFER) AND DRAWING DOCUMENTS ARE COMPLEMENTARY. WHERE ANY
A-04 Internal Elevations - WC ERRORS, AMBIGUITIES, INCONSITENCIES, OR ANOMALIES MAY OCCUR CONTRADICTING BETWEEN THE
A-06 Roof Plan DRAWINGS AND THE CONTRACT (OR QUOTATION OFFER), THEN THE CONTRACT GOVERNS THE DRAWINGS
UNLESS NO RELEVANT INFORMATION IN THE CONTRACT IS PROVIDED.
E-01 Electrical and Lighting Plan
A-00 General Notes and Sheet List
A-07 3D Views and Schedules
10000
90 7730 90 2000 90
1
A-03
W1
A
DP
90
4 A-04 1
1
Store 2
29 m Toilet
4000
3820
4 A-05 2
8 m
3 Vinyl
Vinyl
D1
D2
90
B
2
S-01 1
A-03
90 2630 3100 2000 820 1030 90
90 150
1 Floor Plan
1 : 50
Door Schedule
Mark Location Height Width Thickness Finish Frame Material Comments
D1 Store Room 2100 3100 Colorbond Steel Roller Shutter
D2 WC 2040 820 38 Painted MDF
Window Schedule
Mark Location Window Style Width Height Material Glazing Remarks
W1 WC Ablution Sliding 700 350 Aluminium Clear Flyscreen
FCL FCL
2400 2400
2850 nom.
Fibre Cement Cladding
Scyon Stria
3220
1300
FFL FFL
0 0
BFL
-225
BFL
-225
1 Front Elevation 2 East
1 : 50 1 : 50
3 2 1
A B
750x350 Aluminium Frame Ablution Colorbond Custom Orb Roof Colorbond Louvre Vents
Window with Permanent Ventilation Sheeting
5 Mesh
FCL FCL
2400 2400
3220 nom.
2850 nom.
2870
FFL
FFL 0
0
BFL BFL
-225 -225
10028
4 West 3 Rear Elevation
1 : 50 1 : 50
FASCIA
Colorbond Fascia
100x50 Rectangular Colorbond Downpipes
FCL
2400
WINDOWS
Aluminium Frame Ablution Window with
Permanent Ventilation Mesh
INTERNAL PARTITIONS
90mm Steel Stud Framing
9mm MDF Lining Both Sides. Flush Joint.
FFL
0
BFL
-225
FLOOR STRUCTURE
2mm Vinyl in Storage Area
1 Typical Section 2mm Non-Slip Vinyl in Toilet Area
1 : 25 18mm Compressed Fibre Cement Substrate
100nn Vinyl Skirting "Featheredge"
R1.0 Polysterene Insulation Sheets
Base Frame to Engineer's Design
EQ
EQ
Paint
FCL FCL
2400
Colorbond Surfmist 2400
Paint
Colorbond Surfmist EQ EQ
860
530
500
730 1LT
2100
2GPO
Hook
1500
P/Towel
1100
1100
870
1000
1000
Light
Basin
850
850
600
FFL FFL
0 0
1 WC - EAST 2 WC - SOUTH
1 : 50 1 : 50
400
FCL
2400
FCL
2400
Proposed S/Board
Location
1500
FFL
0
FFL 620
0
4 WC - WEST 3 WC - NORTH
1 : 50 1 : 50
FCL FCL
2400 2400
350
EQ
EQ
FCL FCL
2400 2400
FFL FFL
0 0
1760 1400
Colorbond Rectangular
Colorbond Gutter Downpipe 100x50
LYSAGHT Quad Profile
5
BMT: 0.42
2 Rear 3D View
Double GPO
Switchboard
2x36W
Double Fluorescent Light
2x36W
2x36W
2x36W
Electrical and Lighting Legend
1 : 50
1000AFL
1000AFL
300AFL
1000AFL
EM
EM
MB EM 100x50x3.0 RHS End Member
FJ1 50x50x1.6SHS Floor Joists
A FJ2 75x50x2.0 RHS Flat Internal Partition Support Joist
S-01
MB 150PFC Main Bearer
1550
P1 C150-1.9
EM
EM
CM
TH Topspan 40(VIC)
CB CB CB
4000
B
S-01
ALL STEEL MEMBERS TO BE COLD GALV SPRAYED
ALL MEMBERS CONNECTIONS TO HAVE 6CFW UNO
ALL HOLLOW SECTION ENDS TO HAVE 3MM CAP PLATES
1550
EM
EM
MB
450
EM
EM
LP A LP
S-07
2 D
S-01 S-01
1 BEARERS SETOUT c
a A B S-03
1 : 50 S-03 b S-01
50x50x1.6SHS @ 450CTS Max S-03
S-01
1
1
PJ
PJ
PJ
EM PJ
FJ
FJ
FJ
LP LP
B
C
EM
MB CONTINUOUS CM CONTINUOUS
M
B
C
M
1338 8663 450 1550 1550 450
PJ
CB CB CB EM EM EM EM
M
B
C
B
C
M
M
1400 7200 4000
1
75x50x2.0 RHS Flat
C
C
A
S-02 7865 2135
75x50 Flat
C1 TO PJ
6CFW TWO SIDES
FFL
0
BFL
-225
A C1 TO PJ (TYP)
1 : 10
1
1
FJ
FJ
PJ
PJ TO EM
6CFW
75mm LONG
EM
MB MB
EM TO MB
M
6CFW
C
BOTH SIDES
CM TO MB PJ TO FJ1
6CFW 6CFW
BOTH SIDES BOTH SIDES
50 270 50
FJ1
PJ
SLEEVE
75x75x4
LIFTING POINT (LP) END PLATE 6CFW TO STIFFENER
SEE LIFTING POINT DETAIL 75x65x10 3x50 LONG BOTH SIDES
CM FOR MEMBER SIZES 6CFW BOTH SIDES END PLATE
100x65x10
ARM
6CFW BOTH SIDES
LP TO FJ AND STIFFENER 65x65x5
B
c LP TO MB DETAIL (TYP)
1 : 10
3
OPENING OPENING OPENING
310Hx640W @ 1720 310Hx640W @ 1720 310Hx660W @ 1720
F1
3
F4
4 A-04 1
2
S-05 1 1 S-06 1 4 S-05
4 A-05 2
3
F8
844
1
1
OPENING
C
C
2055Hx844W @ 0
F7 2 F5
S-05
3. ALL FRAMING SECTIONS TO BE MANUFACTURED FROM CONTINUOUS GALVANISED SHEET STEEL CONFORMING TO AS1397.
4. WELDING OF FRAMES SHALL BE BY THE METAL INERT GAS TECHNIQUE (MIG). CONFORMING TO AS 1554. (WELDING CODE )
5. FABRICATION AND ERECTION OF STEEL FRAMES SHALL CONFORM WITH THE REQUIREMENTS OF AS 4600 -2005 (COLD FORMED STEEL STRUCTURES CODE).
7. HOLES FOR PLUMBING OR ELECTRICAL SERVICES MAY BE EITHER PLAIN HOLES OR FLANGED HOLES TO A MAXIMUM OF 50mm DIAMETER PROVIDED NOT MORE THAN 2 HOLES ARE
EMPLOYED. THE HOLES CANNOT BE ADJACENT TO ONE ANOTHER AND MUST BE LOCATED WITHIN 100mm OFF END AND MIDSPAN POINTS OF THE STUD.
528
527
826
1200
1200
F5 844
C1 Cut Length
F1 F7 F6
2928
2927
2952
2594
C1
C1
Timber Blocking
for Basin
2055
300
1200
1200
220 600 600 600 600 195 600 600 600 58 120 108 874 41 600 348 105
600 600 600 600 600 600
2595 3173 TBC 4053
3820
F7 F6 F5
10000
5000 5000
Exhaust Fan Location Frame 3 Frame 2
Allow for Timber Blocking 349 690 2360 670 931 2899 670 1431
Clear Clear Clear
528
194
564
564
S/Board
Location
Clear
310
310
1200
1200
F4
F3 F2
2928
2594
2594
1720
1720
1200
1200
Allow Timber
Blocking for Toilet
Roll Holder
600 600 600 600 600 600 220
600 600 600 405 600 600 600 600 200 600 600 600 600 600 600 600 495
105 105
3820 95 75 120
1200
F8
2754
2422
1200
1200
220 600 600 600 600 600 600
3820
1 WALL FRAME 7
1 : 50
200 A 200
S-07 64 75
1200 1200 1200 1200 1200 1200 1200 1200
TH CH
17
A
CH: C CHANNEL 150-1.9
P1: C PURLIN 150-1.9
760
TH: TOP HAT 40
155
152
119
TH
17
1195
1.9
1.9
TH
P1 PURLIN PROFILE CH CHANNEL PROFILE
P1
P1
P1
P1
P1
P1
P1
P1
P1
a b
1:5 1:5
1195
TH
760
TH CH P1 TO CH
B 6CFW 3x10mm
TO TOP AND BOTTOM FLANGE
1
1
TOP HAT 40
C
C
A
TH
S-07 FIXED TO WALL FRAME OR PURPLIN
ROOF FRAMING WITH M6 -11 x 50 HEX HEAD ROOF ZIPS
H
1
C
1 : 50
P1
FCL
A B 2400