You are on page 1of 2

cam

cam operated
operated Y Series control relays
control relays control relays
switchwes
switches A5 Changeover Motorswitch

Automatic Transfer Unit

Functions
Automatic transfer units are used on backup supply systems to operate complete supply
transfers. It integrates Y5 Automatic Changeover Switches with a control logic that will
run the process. This logic is managed by phase failure relay and timers programmed
upon application requirements. Y Series
According to
IEC 947-6-1
Changeover Motorswitch
IEC 61000

PHASE CONTROL
RELAYS
time fuse protection
Over/under voltage. automation and control ABK Fuse
switches Protection
TIMERS Phase sequence and
Start/stop generator. failure control.
Transfer delays. Fault time delay.

OUTPUT AUXILIARY
CONTACTS
Voltage free.
Signal.
Generator control.

PLUG AND PLAY

System diagram

Fault Logic Start engine


Genset

phone. +34 93 842 48 87


gave electro s.a. fax. +34 93 842 27 55
Industry P.O. BOX 12 www.gave.com
and services 08430 La Roca del Valls export@gave.com

Y5.02
Automatic Changeover Switch VISUAL INDICATION OPERATION COUNTER
Technical Data
63A 100A 125A 160A 200A
Internal processor stores
number of operations. rated voltage V AC 690 690 690 690 690
Functions frequence Hz 50 50 50 50 50
3 pushes start blinking display.
Y5 motorised changeover switches 5 digits appear displaying num- thermal rating Ith A 80 125 150 160 200
have been designed to operate remote manual ber of operations.
automatic changeover operations. They thermal rating Ith A 63 100 125 160 200
digital position mode signaling
increase electromechanical security on AC-23 230V AC kW 15 18,5 18,5 30 38
indication
automatic remote operations. 400V AC kW 22 30 37 52 65
2.201 operations 500V AC kW 30 37 45 65 80
2
shaft indicates flexible wire mm 16-50 16-50 16-50 95 95
According to mechanical position standed wire mm 2
16-50 16-50 16-50 95 95
IEC 947-3 motor consumption peak A 2,5 2,5 2,5 2,5 2,5
IEC 61000 ISOLATED CIRCUITS PADLOCKING nominal A 1 1 1 1 1
Integrated internal link. Unit lockable up to 4 padlocks. weight gr 2.250 2.250 2.250 2.850 2.850
Cam mechanical interlock, Manual mode operation disables connection open cable clamps M8 ring terminal M8
prevents parallel connection motor.
under all circumstances.

Reference description Input wiring 1 0 2 - +


3 changeover position inputs.
MANUAL EMERGENCY OPERATION COMPACT SIZE ELECTRONICS
voltage drop
GAVE SWITCHING TECHNOLOGY
Permits heavy loads operation.
Y - 563 6 1 0 0 2 power supply inputs.
Wiring supply protected
Possibility to perform manual operation. Minimum dimensions. against wrong polarity.
Manual operation overrides automatic Mounting flexibility. EMC tested protection High electrical and mechanical endurance. supply: 1 12V DC
2 24V DC
operation. load break 4 48V DC
3 80 to 220V AC
mechanism Power supply
rating: 6 63A 7 125A reference input supply
8 125A A 160A
B 200A 24V DC VC 24D 19-36V DC
48V DC VC 48D 36-72V DC
motor block connection scheme: 553 switch Multivoltage VC MAC 120-370V DC
magnetic position
563 changeover
remote detection 640 star-delta
operation 671 inverter - size: 99x97x38
integrated auxiliary - output supply: 12V DC / 25W.
contacts (references different from 12V DC
Y Series Motorswitch are served with a power supply.)
Possible applications Dimensions
NORMAL - EMERGENCY STAR - DELTA REVERSING ON - OFF SWITCH 63A to 125A 160A to 200A

On industrial and public service Motor switching-on can be Industrial process typically Industrial, public and private
establishments demanding automatically operated by require automatic motor systems demand remote
continuous electrical supply, a a star-delta changeover reversing with optional automatic on-off switching.
generator is installed requiring switch. manual operation.
Dimensions in mm.
a changeover operation.