TECHNICAL
CHARACTERISTICS
Pulse-induction system
Work frequency - 100Hz
Impulse power - 210W
Terminals for coils and for charging
Supplying device with built in accumulator - 12V/1.2Ah
Working time with once charged accumulator - 10-12 hours
Automatic charge device with led indication
Time of charge battery -10-12 hours
Battery testing automatic light test control
Sizes - 203 x 166 x 66 mm
Net weight - 1500 gm
Maximal deep for large target up to 6 meter whit 1x1m. coil
Consummation of coils 28cm, 40X 40, 50 X 50 with - ~130 mA
Consummation of coil 110 X110cm - ~190 mA
Voltage - 12V
MAIN FUNCTIONS
POWER switches the detectors and regulates its power .
There are ten power levels as it works mainly on 9 or 10 level.
GAIN regulates the power of gained signal. When the
soil is normal it works mainly on level 10.
THRESHOLD a threshold tone. In dry soil it normally
works on level 9 or 10. When the moisture is high its good to work under
level 8.
SIGNAL eliminates soil mineralization.
When soil is normal its good to work on level 8 to 10, while the soil is
highly mineralized its recommended to work on level 0 to 3.
NOISE eliminates influence of Roman pottery over the
apparatus, its used in combination with SIGNAL.
FAST ZERO press this button for about 2-3 seconds
when the detector is ready to work with and the coil is over the ground.
Pressing this button eliminates ground mineralization and the detector
chooses itself the most suitable depth for searching. While press the button
fast zero you must
be sure there is no metal objects under the coil. We recommend press this
button every 4-5 minutes.
LOW BATTERY if the light switches on while
operating, it shows its necessary to charge the battery. If it happens,
please, do not use the detector.
COIL a coil jack.
3. Signal tone rises slowly over a small parcel and then slowly does
down. It indicates for a middles big object buried in a range of 1-2 meters.
You can make your measurements as you bury different sized object in
different range of depths at least 1meter on another for testing small coils,
and at least 4 meters for testing one or two meters coils. While working
with the detector be consistent and keep notes for all your measurements as
you point the parcel and its structure of soil, the depth of buried objects,
and the kind of the object, the settings of buttons that localize the position
of the
object. As more experiments you make as much you will form your
professional experience.
BATTERY CHARGE
POWERSCAN 2Pro possesses a rechargeable storage battery. If a
light "Low battery" /red led/ switches on while working with the apparatus
you must spot work and recharge the battery. Plug in the jack "CHARGE"
of the charge set into electric net of
220V. After some hours the battery will be recharged. The charge set will
automatically switch off when the battery is ready so the battery cant be
damaged if it stays longer in the charge set. When its ready, in the reverse
order take the jack back
of the "CHARGE".