Name of the Company: Digital Energy Engineering Services WLL. Location: Qatar
Working Duration: Feb 2014 to Till now Designation: Testing &Commissioning
Junior Engineer

The organization is an ISO 9001:2008 certified. It has growing up steadily to become one of
the top class engineering organization offering quality services in substation, electrical engineering,
testing and commissioning . Our main customers are L&T, SIEMENS, NCC, ALSTOM,
ABB...etc.

PROJECT HANDLED
Client: M/s KAHRAMAA Customer: M/s LARSEN&TOUBRO

Project & Role: 66/11KV DIF S/S.


Worked as a Sr.TECHNICIAN within 5 months period.
66KV 4 LINES, 40MVA TR * 2, 2 Bus coupler, 2 Bus Section double bus bar
Scheme.(SIEMENS GIS)
11KV for 20 LINES, 2 ICF, 1 Bus Section (TAMCO).
Project & Role: 220/132/22KV NEW PORT SUPER S/S

Worked as a Sr.TECHNICIAN within 5 months period.


Which have 220KV 4 LINES, 315MVA auto transformer * 3, 2 Bus coupler, 2 Bus section,
double bus bar scheme (SIEMENS GIS).
132KV For 8 LINES + 3 ICF , 60MVA TR * 3, 2 Bus coupler, 2 Bus Section double bus
bar scheme (SIEMENS GIS).
22KV 21 LINES + 3 ICF, 2 Bus Section scheme (SIEMENS GIS).
Project & Role: 220/66/11KV ABU HAMOURS/S
Worked as a Sr.TECHNICIAN
Which have 220KV 4 LINES, 315MVA auto transformer * 3, 2 Bus coupler, 2 Bus section
double bus bar scheme (SIEMENS GIS).
which have 66KV 4 LINES, 40MVA TR * 2, 2 Bus coupler, 2 Bus Section double bus bar
scheme .(SIEMENS GIS)
11KV For 20 LINES, 2 ICF, 1 Bus Section (TAMCO).
Project & Role: 132/22KV NEW PORT - 1 S/S
Worked as a Sr.TECHNICIAN within 6 months period.
132KV For 4 LINES, 60MVA TR * 3, 2 Bus coupler, 2 Bus Section double bus bar scheme
(SIEMENS GIS).
22KV 21 LINES + 3 ICF, 2 Bus Section scheme (SIEMENS GIS).
Client: M/s KAHRAMAA Customer: NCC
Project & Role: 66/11KV POLICE TRAINING INSTITUTE S/S

Worked as a Sr.TECHNICIAN within 6 months period.


66KV For 6 LINES, 40MVA TR * 2, 20 Bus coupler, 2 Bus Section double bus bar scheme
11KV - 21 LINES + 3 ICF, 2 Bus Section scheme.
Project & Role: 66/11KV AL- KALADHIYA S/S.
Worked as a Sr.TECHNICIAN within 5 months period
Which have 66KV 4 LINES, 40MVA TR * 2, 2 Bus coupler, 2 Bus Section double bus bar
Scheme. (SIEMENS GIS).
11KV for 20 LINES, 2 ICF, 1 Bus Section
Project & Role: 66/11KV MONTAZA S/S
Worked as a Sr.TECHNICIAN within 5 months period.
which have 66KV 4 LINES, 40MVA TR * 2, 2 Bus coupler, 2 Bus Section double bus bar
Scheme .(SIEMENS GIS)
11KV for 20 LINES, 2 ICF, 1 Bus Section.
Client: M/s KAHRAMAA Customer: SIEMENS
Project & Role: 132/66/11kV WAKRAH REPLACEMENT S/S
Worked as a Sr.TECHNICIAN within 8 months period
132KV For 8 Bays , 2 Bus section, 2 Coupler , & 2 Incomers
66KV For 8 Bays , 2 Bus section, 2 Coupler , & 4 Incomers
11KV SWGR A & B For Each 25 Bays Including Bus Section, Incomers & Auxiliary
Transformer Along with LVAC & LVDC
Project & Role: 132/11kV AL JAHHANIYA 3 S/S
Worked as a Sr.TECHNICIAN within 8 months period
132KV For 6 Bays , 2 Bus section, 2 Coupler , & 2 Incomers
11KV SWGR - 25 Bays Including Bus Section, Incomers & Auxiliary Transformer Along with
LVAC & LVDC
Key Responsibility Areas
Internal And External Wiring Check Of Power And Control Panels As Per Schematic Drawings.
Protection & Power Control Panel Modification Work.
Testing and Commissioning For 132/66/11 kV Components.
CT, VT, Circuit Breaker Testing.
CT, VT Primary and Secondary Injection Test.
AC/DC Checks of Switchgear and Relay Panel.
Auxiliary Relay Testing.
Binary Input Checking.
Mechanical And Electrical Interlock Checking Of 11 kV Switchgear.
MCCB, Meters, Annunciation circuit
CB/DS/ES timing, contact resistance & motor current measurement

Performing Equipments:
A. CT Analyzer
B. CPC 100
C. EGIL/CB timing
D. MOM/Contact resistance
E. SVERKER
F. B10
G. FREJA 300
H. Insulation Resistance tester
I. ODEN AT
J. Hv Testing Kit
K. CMC 256/356

Domestic Experience: 1 Year.

Name of the Project Location Nature of work Duration

Om Srinivasa Paper Boards 2013- 2014

Key Responsibility Areas


Supervise The Maintenance Department Activities
Responsible For Maintaining And Repairing Electrical switchgear Equipment Required In The
Day To Day Working
Replacing The Electrical Spare Parts Of The Machines As And When Required
Assessment Of The Required Tools For The Maintenance Of The Equipment
Responsible For Performing Routine Maintenance.
Educational Qualification:

Course Institution % of Marks Year of Passing


Diploma in Electrical
& Electronics
Engineering

State Board (S.S.L.C)

Language Proficiency

English & Tamil - Speak, Read, Write


Hindi-Speak
Telugu- Speak

Personal Details:
Name : Mr. Venkatesh
Date of Birth : 01/08/1993
Marital status : Single
Nationality : Indian
Address :
Passport Details:
Passport No : L2329207
Date Of Issue :
Date of Expiry :