You are on page 1of 5

ZOYO::;

MGW MGWVAL02 2012-01-16 14:39:36


INTERROGATING PARAMETER SET DATA
PARAMETER SET NAME: IETF PARAMETER SET NUMBER: 0
RTO.MIN: 1000 MILLISECONDS
RTO.MAX: 60000 MILLISECONDS
RTO.INIT: 3000 MILLISECONDS
HB.INTERVAL: 30000 MILLISECONDS
SACK.PERIOD: 200 MILLISECONDS
PATH.MAX.RETRANS: 5 ATTEMPTS
ASSOCIATION.MAX.RETRANS: 10 ATTEMPTS
CHECKSUM: CRC32
BUNDLING: YES

PARAMETER SET NAME: SS7 PARAMETER SET NUMBER: 1


RTO.MIN: 150 MILLISECONDS
RTO.MAX: 200 MILLISECONDS
RTO.INIT: 200 MILLISECONDS
HB.INTERVAL: 1000 MILLISECONDS
SACK.PERIOD: 110 MILLISECONDS
PATH.MAX.RETRANS: 2 ATTEMPTS
ASSOCIATION.MAX.RETRANS: 4 ATTEMPTS
CHECKSUM: CRC32
BUNDLING: YES

PARAMETER SET NAME: SCTP PARAMETER SET NUMBER: 2


RTO.MIN: 150 MILLISECONDS
RTO.MAX: 200 MILLISECONDS
RTO.INIT: 3000 MILLISECONDS
HB.INTERVAL: 1000 MILLISECONDS
SACK.PERIOD: 110 MILLISECONDS
PATH.MAX.RETRANS: 2 ATTEMPTS
ASSOCIATION.MAX.RETRANS: 4 ATTEMPTS
CHECKSUM: CRC32
BUNDLING: YES
COMMAND EXECUTED

OYO:NBR=3:;
/*** ERROR: 16023 ***/
/*** PARAMETER SET DOES NOT EXIST ***/
COMMAND EXECUTED

Por lo que se envian los comando necesarios para su revision y aprobacion a fin de
normalizar el parametro Nr 3, H248:

1.- CREACION DEL PARAMETRO H248 (NO ESTA CREADO):

ZOYE:H248:SCTP:;

En donde el primer campo es el nombre del parameter y el segundo es el nombre de


un parameter ya existente, aqu se est clonando el parameter SCTP existente y luego
toca modificar los timer (TAL Y COMO SEA SUGERIDO EN LA REVISION)

2.- Luego se chequea que se haya creado correctamente el H248 parameter set 3:
ZOYO: NBR=3;

3.- Cambiar BUNDLING:

ZOYT:H248:BUNDLING=N:;

Para poder realizar los cambios en los VMGW, realizar los siguientes pasos:

A continuacin los Comandos para realizar los cambios sobre el MGW VAL02:
DESREGISTRO - CAMBIO DE LOS PARAMETROS Y REGISTRO VMGW MSS VAL02 -->
MGW VAL02,

Lado MSS:

1.-
Interrogando los VMGW :
ZJGI:::;

MSCi MSSVAL01 2012-01-16 13:47:43


MGW DATA:
MGW ID MGW NAME MGW TYPE CTRL UNIT ID REG STATUS PARSET: USED/DEF
MGW IP ADDRESS/DOMAIN NAME
0 VMGWVAL106 GENERAL SIGU 24 REGISTERED 0/0
10.19.66.39
1 VMGWVAL100 GENERAL SIGU 7 REGISTERED 1/1
10.19.66.33
2 VMGWVAL101 GENERAL SIGU 13 REGISTERED 2/2
10.19.67.34
3 VMGWVAL102 GENERAL SIGU 16 REGISTERED 3/3
10.19.66.35
4 VMGWVAL103 GENERAL SIGU 3 REGISTERED 4/4
10.19.67.36
5 VMGWVAL104 GENERAL SIGU 20 REGISTERED 5/5
10.19.66.37
6 VMGWVAL105 GENERAL SIGU 14 REGISTERED 6/6
10.19.67.38
7 VMGWVAL107 GENERAL SIGU 4 REGISTERED 7/7
10.19.67.40
8 VMGWVAL108 GENERAL SIGU 11 REGISTERED 8/8
10.19.66.41
9 VMGWVAL109 GENERAL SIGU 6 REGISTERED 9/9
10.19.67.42
30 VMGWVAL300 GENERAL SIGU 13 REGISTERED 30/30
10.19.66.17
31 VMGWVAL301 GENERAL SIGU 10 REGISTERED 31/31
10.19.67.18
32 VMGWVAL302 GENERAL SIGU 15 REGISTERED 32/32
10.19.66.19
33 VMGWVAL303 GENERAL SIGU 1 REGISTERED 33/33
10.19.67.20
34 VMGWVAL304 GENERAL SIGU 17 REGISTERED 34/34
10.19.66.21
35 VMGWVAL305 GENERAL SIGU 5 REGISTERED 35/35
10.19.67.22
36 VMGWVAL306 GENERAL SIGU 7 REGISTERED 36/36
10.19.66.23
37 VMGWVAL307 GENERAL SIGU 9 REGISTERED 37/37
10.19.67.24
38 VMGWVAL308 GENERAL SIGU 12 REGISTERED 38/38
10.19.66.25
39 VMGWVAL309 GENERAL SIGU 24 REGISTERED 39/39
10.19.67.26
-------------------------------------------------------------------------
40 VMGWVAL200 GENERAL SIGU 16 REGISTERED 40/40
10.19.66.49
41 VMGWVAL201 GENERAL SIGU 2 REGISTERED 41/41
10.19.67.50
42 VMGWVAL202 GENERAL SIGU 0 REGISTERED 42/42
10.19.66.51
43 VMGWVAL203 GENERAL SIGU 9 REGISTERED 43/43
10.19.67.52
44 VMGWVAL204 GENERAL SIGU 15 REGISTERED 44/44
10.19.66.53
45 VMGWVAL205 GENERAL SIGU 1 REGISTERED 45/45
10.19.67.54
46 VMGWVAL206 GENERAL SIGU 17 REGISTERED 46/46
10.19.66.55
47 VMGWVAL207 GENERAL SIGU 10 REGISTERED 47/47
10.19.67.56
48 VMGWVAL208 GENERAL SIGU 12 REGISTERED 48/48
10.19.67.57
49 VMGWVAL209 GENERAL SIGU 11 REGISTERED 49/49
10.19.66.58
--------------------------------------------------------------------------------
51 VMGWMCY101 GENERAL SIGU 25 REGISTERED 11/11
10.19.115.5
COMMAND EXECUTED

2.- Se desregistra los VMGW (Lados MSS):

Nota: los MGWID nombrados son los pertenecientes al MGW VAL02

ZJGR:MGWID=40:METD=1,REGA=N,:;
ZJGR:MGWID=41:METD=1,REGA=N,:;
ZJGR:MGWID=42:METD=1,REGA=N,:;
ZJGR:MGWID=43:METD=1,REGA=N,:;
ZJGR:MGWID=44:METD=1,REGA=N,:;
ZJGR:MGWID=45:METD=1,REGA=N,:;
ZJGR:MGWID=46:METD=1,REGA=N,:;
ZJGR:MGWID=47:METD=1,REGA=N,:;
ZJGR:MGWID=48:METD=1,REGA=N,:;
ZJGR:MGWID=49:METD=1,REGA=N,:;

3.- Se Interroga nuevamente y se observan los cambios aplicados. Deben quedar con
condicion: NOT REGISTERED

MSS:
ZJGI:::;

4.- Se realizan los cambios solicitados . ASOCIACION DEL NUEVO PARAMETER SET A
TODOS LOS MGWID (MGW)
MODIFY VIRTUAL MGW CONTROL DATA

ZJVN: VID=0,::NBR=3,:::; esto para todos los VMGW (0-9)

4. 1.- Comando para verificar el cambio:

JVI:VID=0,:MOD=2,; Cambiar el VID de 0 al 9

5.- Se registran los VMGW nuevamente en el MSS:

ZJGR:MGWID=40:METD=1,REGA=Y,:;
ZJGR:MGWID=41:METD=1,REGA=Y,:;
ZJGR:MGWID=42:METD=1,REGA=Y,:;
ZJGR:MGWID=43:METD=1,REGA=Y,:;
ZJGR:MGWID=44:METD=1,REGA=Y,:;
ZJGR:MGWID=45:METD=1,REGA=Y,:;
ZJGR:MGWID=46:METD=1,REGA=Y,:;
ZJGR:MGWID=47:METD=1,REGA=Y,:;
ZJGR:MGWID=48:METD=1,REGA=Y,:;
ZJGR:MGWID=49:METD=1,REGA=Y,:;

6.- En el MGW Afectado, se debe registrar el VMGW ya que cuando se desregistra en


el MSS el mismo queda afectado (NO REGISTERED) en el MGW

Lado MGW:

JVI::::;

MGW MGWVAL02 2012-01-16 14:09:45


VIRTUAL MGW DATA:
VMGW ID VMGW NAME REGA REG STATUS (M)ISU UNIT (S)ISU UNIT(S)
======= ================ ==== ============== =========== ================
0 VMGWVAL200 Y REGISTERED 10 -
1 VMGWVAL201 Y REGISTERED 4 -
2 VMGWVAL202 Y REGISTERED 6 -
3 VMGWVAL203 Y REGISTERED 2 -
4 VMGWVAL204 Y REGISTERED 9 -
5 VMGWVAL205 Y REGISTERED 3 -
6 VMGWVAL206 Y REGISTERED 5 -
7 VMGWVAL207 Y REGISTERED 7 -
8 VMGWVAL208 Y REGISTERED 1 -
9 VMGWVAL209 Y REGISTERED 8 -

6.1 Registrando el VMGW en el MGW:

ZJVR:VID=0,:REGA=1,MET=1,:;
ZJVR:VID=1,:REGA=1,MET=1,:;
ZJVR:VID=2,:REGA=1,MET=1,:;
ZJVR:VID=3,:REGA=1,MET=1,:;
ZJVR:VID=4,:REGA=1,MET=1,:;
ZJVR:VID=5,:REGA=1,MET=1,:;
ZJVR:VID=6,:REGA=1,MET=1,:;
ZJVR:VID=7,:REGA=1,MET=1,:;
ZJVR:VID=8,:REGA=1,MET=1,:;
ZJVR:VID=9,:REGA=1,MET=1,:;

7.- Una vez efectuado el cambio en el MGW se revisa en el MSS a fin de observar que
los cambios hayan surtido efecto, con esto se debe observar finalmente el Registro de
los VMGW:
ZJGI:;