You are on page 1of 2

FORMAT UTILE:(841 X 594)

8 7 6 5 4 3 SIZE

A1
DWG.NO.

209D7247
SH.

1/2
REV.

A 1
REVISIONS

REV DESCRIPTION DATE NAMES/NOMS

AFR FB.
NOTES: A FIRST ISSUE 26/10/2010 NGUYEN A.
DELIMOGES S.

1 - VOIR MLI 0414, NOMENCLATURE DES APPAREILS, POUR REGLAGE DES APPAREILS.
1 - SEE MLI 0414, DEVICE SUMMARY, FOR CONTROL DEVICE SETTINGS.

D 2 - VOIR MLI 0313 ET 0314 POUR LES CARACTERISTIQUES DES CONNEXIONS CLIENT. D
2 - SEE MLI 0313 AND 0314 FOR CHARACTERISTICS OF THE CUSTOMER CONNECTIONS.

3 - VOIR ITEMS 3 ET 4 DU TABLEAU DE " LIST OF REFERENCE DOCUMENTS " POUR LES CARACTERISTIQUES DES FLUIDES.
3 - SEE ITEMS 3 & 4 OF THE " LIST OF REFERENCE DOCUMENTS " FOR FLUID CHARACTERISTICS.

4- VOIR MLI 0512 POUR PURGE PASSIVE. CHAQUE LIGNE DOIT ETRE CONNECTEE A LA BRIDE DE PURGE DIFFUSION DE CHAQUE CHAMBRE.
4 - SEE MLI 0512 FOR PASSIVE PURGE. EACH LINE WILL BE CONNECTED TO THE PURGE DIFFUSION FLANGES OF EACH COMBUSTION CAN.

5 - VERIFICATION DES FILTRES TEMPORAIRES APRES 50 HEURES DE FONCTIONNEMENT EN BASE LOAD.


SI FILTRES ENCRASSES, LES NETTOYER ET LES REINSTALLER SINON LES DEMONTER.
5 - CHECK TEMPORARY STRAINERS AFTER 50 HOURS OF BASE LOAD OPERATING.
IF STRAINERS DIRTY, CLEAN THEM AND REINSTALL THEM, OTHERWISE REMOVE THEM.

A A REV
REV STATUS
OF SHEETS
2 1 SH

1 FLUID DIAGRAM SYMBOLIZATION (ISA) GE-123E4888

2 EXTRA RULES FOR 04XX SCHEMATICS CREATION 379A9908

3 SYSTEM AND COMPONENT CLEANLINESS REQUIREMENTS GE-362A2412


C
4 FLUID SPECIFICATION GEK 106689
C
IT. NOMENCLATURE IDENT

LIST OF REFERENCES DOCUMENTS

FIRST MADE FOR : MS 6591 ITEM : 0417

LEAVE THIS SPACE BLANK

B
B

()*)()+,)-+./0)(-1- E1018 100 I60 FD 002


2 ()<9497+-1-
()<94 A
26/10/2010 26/10/2010 27/10/2010
None
),2--3--4,56) ;58) 26/10/2010
AFR FB
26/10/2010
NGUYEN AILAN
2
27/10/2010
DELIMOGES SYLVAIN
None +7/--3--+5/) AFR FB NGUYENEN AILAN DELIMOGES SYLVAIN
AFR FB NGUYEN AILAN DELIMOGES SYLVAIN
A1
*7(/58-3-49:) <945 AFR FB NGUYEN
UYEN AILAN DELIMOGES SYLVAIN
A1

VALIDE
();9=)--3--/5;) <)(9*9)--3--,2),?);
<)(9* 3--, 5>>(7.<)--3--5>>(7<);

VALIDE
898()-3-8986)

GAS TURBINE
SCHEMA WITH
TUY.AIR ASSOCIATES
REFROIDT.& S ITEMS-PIPIN
ITEMS-PIPING
ETANCHEITE
AND INSTRUMENT DIAGRAM (P&IP&I D)

0417, PID, COOLING & SEALING


NOMS / NAMES
DIAG.SCH.PP-CLG & SLG ALING AIR
AIR
DRAWN
AFR FB.
NGUYEN A.

IOAN
CHECKED

APPROVED DELIMOGES S. SCHEMA TUY. AIR REFROIDT. &


A 
  

ETANCHEITE

GEORGESCU
()<9497+
 
 
A




 
  


DIAG. SCH. PP-CLG & SLG AIR A

user

     

0417   


 
  
  9+48(.,897+-;)

super
-/7;9*9,5897+

+G 209D7247

  

 
  209D7247
SIZE CAGE CODE DWG.NO.

209D7247
This document, exclusive property of
A1

DISTR
Ce document, proprit exclusive de 4@ABCDE-;DAF


 


 


TO
GE Energy Products France SNC est GE Energy Products France SNC
strictement confidentiel. Il ne peut tre communiqu, is strictly confidential. It must not be communicated  
      01 FX
copi ou reproduit sans son autorisation crite pralable. copied or reproduced without our previous written consent. 

   

  

SIM TO: 219D1246 1/2
42))8F-+G1/2
SCALE REV. : A SHEET : 1/2

8 7 6 5 4 3 2 1
FORMAT A1:841 X 594 (ISO 5457-1980)
FORMAT UTILE:(841 X 594)

8 7 6 5 4 3 SIZE

A1
DWG.NO.

209D7247
SH.

2/2
REV.

A 1

VERS / TO MLI 0432


IH3 CA60B CSA001
CA16
PC PC
FO
(96CD-1A) PENTE C
PT SLOPE B A
2% MINI PENTE 2% MINI (63TK-1)
SLOPE 2% MINI PS (VCK7-2) PS (63TK-2)
(VCK7-1)
PENTE
NO (33CB-1B)
S (20CB-1) PENTE
2% MINI.
PENTE 2% MINI (33CB-1A) 2% MINI.
D
WD

D HV301 SLOPE 2% MINI DI 101 DI 800 SLOPE SLOPE DI 801


ZSL ZSH 2% MINI.
105,03 mm 2% MINI.
PENTE CA46A
PT (96CD-1B) SLOPE ( 4.135" ) CA13A
PC
CA13B
2% MINI VERS / TO MLI 0471 CW CCW
FO PC PC
HV101 HV111
NC (VA2-1) NC
NO PENTE 6"x4"
SLOPE
WD

HV303 DRAIN POINT BAS (33CB-3B) (33CB-3A) DRAIN POINT BAS


2% MINI DI 103
WD

LOW POINT DRAIN


WD

LOW POINT DRAIN ZSL ZSH (88TK-1)


PENTE 110,99 mm
(96CD-1C) CA49A M M (88TK-2)
PT SLOPE ( 4.37" ) (23TK-1)
2% MINI PC VERS / TO MLI 0471 (23TK-2)
HV103 FO
WD

HV113
NC (VA2-3) NC (63BN-1)
WD
NO VOIR NOTE 5 WD PS PS (63BN-2)
HV305 SEE NOTE 5 WD
PENTE PENTE
2% MINI.
WD

2% MINI.
WD

VOIR NOTE 4
DRAIN POINT BAS DI 803
MLI 0557T

SEE NOTE 4
CAN #1 DRAIN POINT BAS SLOPE SLOPE DI 804
LOW POINT DRAIN FILTRE 2% MINI.
LOW POINT DRAIN 2% MINI.
CAN #6 WD
TEMPORAIRE
TEMPORARY CW CCW
CAN #5 STRAINER 4"x3" 4"x3" PC PC
EXTRACTION
EXTRACTION AD-4A CA30A CA30B
9e ETGAGE DI 111 CA13C
13e ETAGE
9TH STAGE AD-4B 25,88 mm
13TH STAGE PC (88BN-1) (VCK7-3)
WD

EXTRACTION ( 1.019" )

FULL SIZE ORIFICE


EXTRACTION 6"x8" AD-4C 6"x4" 6"x4" DI 121 M (23BN-1) (VCK7-4) M (88BN-2)
5"x8" 5"x8" 4"x6" 4"x6" 25,88 mm (23BN-2)

PLEIN DEBIT
( 1.019" ) CA30C
WD

DI 123 C
WD

CSA003
WD

PC
C
WD

53,3 mm 3"x4" 3"x4"


( 2.098" )
WD

DI 113
WD
WD

53,3 mm
WD
( 2.098" )

8"x6"
PALIER 1 PALIER 2
COMPRESSEUR TURBINE
N 1 BEARING COMPRESSOR N 2 BEARING
8"x6"

WD

AD-2
DI 124
WD WD

WD

53,3 mm LEAVE THIS SPACE BLANK


DI 200 ( 2.098" )
WD

0,79 mm 3"x4" 3"x4" MANIFOLD AIR DE


DI 114
( 0.031" ) WD

REFROIDISSEMENT CADRE
53,3 mm
WD WD

4"x6" 4"x6" DI 112 DI 122 ECHAPPEMENT


( 2.098" )
WD

WD

5"x8" 5"x8" 25,88 mm 25,88 mm EXHAUST FRAME


AD-1 6"x4" 6"x4" ( 1.019" ) ( 1.019" ) COOLING MANIFOLD
6"x8" WD

EXTRACTION EXTRACTION B
9e ETAGE 13e ETAGE
VOIR NOTE 4

CAN #4
SEE NOTE 4

9TH STAGE DI 104


B 13TH STAGE FILTRE
EXTRACTION EXTRACTION TEMPORAIRE 4"x3" 4"x3" 110,99 mm
CAN #3 VOIR NOTE 5 ( 4.37" )
TEMPORARY (33CB-4A)
SEE NOTE 5
WD

STRAINER ZSL ZSH


CAN #2 CA49B
PC VERS / TO MLI 0471
HV104 (33CB-4B) FO HV114
NC (VA2-4) NC
DI 102
PENTE 105,03 mm
SLOPE
WD
DRAIN POINT BAS 6"x4" WD

LOW POINT DRAIN ( 4.135" ) (33CB-2B) (33CB- DRAIN POINT BAS


2% MINI
ZSL 2A) LOW POINT DRAIN
ZSH
CA46B
PC VERS / TO MLI 0471
 
 E1018 100 I60 FD 002
2  

 A
FO 26/10/2010 26/10/2010 27/10/2010
HV102 HV112
NC (VA2-2) NC None
     26/10/2010
AFR FB
26/10/2010
NGUYEN AILAN
2
27/10/2010
DELIMOGES SYLVAIN
None AFR FB NGUYENEN AILAN DELIMOGES SYLVAIN
DRAIN POINT BAS FO  
AFR FB NGUYEN AILAN DELIMOGES SYLVAIN
DRAIN POINT BAS C
WD

LOW POINT DRAIN WD


LOW POINT DRAIN B A A1
     AFR FB NGUYEN
UYEN AILAN DELIMOGES SYLVAIN
A1

VALIDE
    
   
(20CB-2)

VALIDE
WD

 
S
DI 130 GAS TURBINE
SCHEMA WITH
TUY.AIR ASSOCIATES
REFROIDT.& S ITEMS-PIPIN
ITEMS-PIPING
ETANCHEITE
AND INSTRUMENT DIAGRAM (P&IP&I D)
3,2 mm
( 0.126" )
0417, PID, COOLING & SEALING
NOMS / NAMES
DIAG.SCH.PP-CLG & SLG ALING AIR
AIR
DRAWN
AFR FB.
CA20A
NGUYEN A.

IOAN
CHECKED
PC PC PC
APPROVED DELIMOGES S. SCHEMA TUY. AIR REFROIDT. &
A 
  

ETANCHEITE

GEORGESCU
 
CA60A  
 
A
VERS MLI 0442 



 
  


DIAG. SCH. PP-CLG & SLG AIR A

user
TO MLI 0442 HV201 
     

0417 NC   


 
  
   

super


 209D7247

  

 
  209D7247
SIZE CAGE CODE DWG.NO.

209D7247
This document, exclusive property of
A1

DISTR
Ce document, proprit exclusive de 


 


 


TO
GE Energy Products France SNC est GE Energy Products France SNC