SOFTWARE CHANGE ON JUMP** CONTROL SYSTEM MACHINES

**Designated as J12, J16, J20. Below are some samples:

BEKO WMD26140P-ALM B1 T2 J12 1400 TS TP


F.de LUXE WA1411-BEL B1 T2 J16 1400 TSTP
BEKO WMA630W-NG B1 T2 J20 1300 TS TP

The software of Jump control system is updated as "Jump_40A_48A" for YOC 35/45/54 , ve Truva 1-
2 Mechanical Systems since 22nd December 2006.

You can recognise the new one from sticker on it (see below images). Old and new one is
interchangable. Old stocks can be used.

Old New

The updates which come with this new software are;

1) To prevent " unwanted siphonage" aftter the end of "prewash" step in Cotton and Synthetic
programs, a 10 second idle waiting is added at the end of draining. (To prevent siphonage)

2) Histerisis on "Cotton+Rapid Wash" program is cancelled (Program duration long problem)

3) 400 rpm pre-spins are cancelled in Spin2, Spin3, Spin10 and Spin 11 profiles (To prevent
machine displacing problems)

4) Taking water up to overflow level, when the water level decreases below "heater safety level" bug is
fixed in the software.

5) 7,5 minutes is added to washing after heating step on Cotton 60 Program. (To increase washing
efficiency)

6) Heater step on Cotton 60 program for Truva 1 and 2 mechanical systems is increased 3 minuntes.
(To increase washing efficiency)

7) Spin step is performed at the beginning of test (service) program instead of performing at the end of
the test (service) program.

The different versions of the Test (Service) Program are as theye are given below according to
the machines software:

For Softwares Before Jump_40A_48A


1. All LEDs on the board will start to blink after the door is locked.

2.For the softwares before 32A, 3-6-9 time delay leds will be on in different combinations , related to
the spin potantiometer position.( For max spin 3-9 leds will be on , for no spin no led will be on)

For 32A and following softwares , 1 and 2 auxilary function leds will be on in 4 different combinations,
related to the spin potantiometer position.

3. Take in water from pre-wash compartment

4. Take in water from main wash compartment

5. Take in water from softener compartment (Both PW and MW valves are active)

6. Take in water from main wash compartment if the W/M has a hot valve option (If not this step will
be skipped)

7. The heater will be ON. If the water level inside the tub is not enough for the heater to switch on
then all valves will be turn on to fill the level.

8. Clockwise motor rotation with 52 rpm

9. Counterclockwise motor rotation with 52 rpm

10. Draining and after draining is finished spinning up to maximum speed.

11. Turn on all the valves to fill a certain level in a short time for water leakage test on the production
line.

12. End

13. You can get off the test mode by turning the WM off.

For Softwares After Jump_40A_48A (Also for all machines with Compact
oscillating system)

1. All LEDs on the board will start to blink after the door is locked.

2. First and Second auxilary function leds will be on in 4 different combinations, related to the spin
potantiometer position.

3. Clockwise motor rotation with 52 rpm

4. Counterclockwise motor rotation with 52 rpm

5. Spinning up to maximum speed.

6. Take in water from pre-wash compartment

7. Take in water from main wash compartment

8. Take in water from softener compartment (Both PW and MW valves are active)

9. Take in water from main wash compartment if the W/M has a hot valve option (If not this step will
be skipped)
10. The heater will be ON while there is Clockwise motor rotation with 52 rpm. If the water level inside
the tub is not enough for the heater to switch on then all valves will be turn on to fill the level.

11. Draining

12. End

13. You can get off the test mode by turning the WM off.