You are on page 1of 20

Concentrated savings

for your applications

Altivar 1000
Medium-voltage variable speed drive 0.5 to 10 MW
Altivar 1000:
a compact heavyweight
response to your needs
for medium-voltage
speed control

Power Mines & minerals


Fans, pumps, Conveyors, crushers,
turbine starters fans, pumps

Oil and gas Water treatment


Pumps, compressors, Pumps, air blowers
air blowers, extruders
Increase your productivity,
make greater savings

Altivar 1000 completes the global offer for electrical


distribution, motor control and control systems.

Reduction in energy costs


Protection of motors and equipment
Increased competitiveness
40
less energy with
Reduction in maintenance costs speed control

Energeyncy
Effi ci
bler
ena
Benefit from innovation on
your medium-voltage applications

Better technology Better results


Compact size thanks to medium-voltage IGBT technology Return on investments
Solution with input transformer integrated in the drive enclosures Reduction in installation costs
or placed outside the electrical control room Speed of commissioning
Optimized location of the electrical
control room
Reduction in needs for air conditioning

Long-lasting components Increased productivity


Optimum sizing Lower production and maintenance costs
Redundancy of pump or cooling fan as standard Enhanced reliability and continuity
Proven control: of operation
- torque and speed with or without sensor
- catch on the fly, suppression of critical speeds

User-friendly interface Simplicity of operation


Easy remote access to the device parameters Saves time during use
Highly modular design Ease of maintenance
Simple access to enclosure front panels

dV/dt or output sinus filter: No disturbance of the motor and the


- reduction in harmonics and stress on the motor, driving load
cables and the driven load Improved motor durability
- quality of the current and voltage waveform Maximum machine efficiency without risk
Compatibility with new or existing motors
Extended cable length between motor and
drive permitted

Solutions with 12/24/36 pulse diode bridge or active rectifier: Perfect integration in the line supply
- better power factor and harmonics than the values imposed Energy losses minimized
by the standards No malfunctions or interference with the
environment

IP41 as standard Enhanced safety


IP54 as an option on water cooled enclosures Dust and damp protection as standard
Electromechanical door locking Protection of people and equipment

A comprehensive offer: A range of high-quality services


- medium and low-voltage drives, motor, electrical distribution, A One-Stop-Shop throughout the life of the
control systems, installation installation
- associated expertise (energy efficiency, line supply study, etc.) Advice and follow-up from specification to
after-sales
International coverage
Reliability and performance

y in
ve
r te
r
Air cooled version
Fre
q u en
c
(up to 4 MW)
A
 simple electrical connection is required
er
In co
m Y
 our equipment is protected by the circula-
tion of cooled filtered air

ut
tp
BT Ou ctor
IG a
rs re
e rte
Inv
e
od
Di dge r
i te
br
Wa ling ent
o
co ipm
u
eq
r
r te
ve
y in
nc
que
Fre
er
om
Inc

Water cooled version


(up to 10 MW)
Enhanced noise reduction:
70 dB (A)
ut
Very low heat losses in the electrical tp
Ou ctor
control room te
rs rea
er
Inv
e
od
Di dge
i
br

r
r te
ve
y in
nc
q ue
Fre

Integrated transformer for


om
er quick, compact installation
Inc

ut
tp
Ou ctor
rs rea
te
er
Inv
e
od
Di dge
r i
b
er
rm
nsfo
Tra
Benefit from excellent efficiency
with technology that is more simple,
more flexible, more reliable

High-voltage IGBT at the heart of the solution

The 3-level inverter topology using high-voltage IGBTs in conjunction


with an advanced control strategy can be used to obtain:

Increased reliability due to a reduction in the number of components


Minimized losses since the IGBT does not need a snubber and
requires little switching power
No pulse torque
Minimized harmonics on the motor
Intrinsic safety: current switched off instantaneously in the event
of a fault

Optimum output current quality

Compact size: Up to 1.5 MW


~99 %
effiency, one of the best
> 50 000 h
MTBF: more than 4 fault-free years
per meter of enclosure on the market
Air cooling for a standalone installation
(up to 4 MW)
Example of a 2 MV drive

Simplicity of use
Direct access to
the power electronics

Compactness Continuity of operation


and accessibility Redundant fan as standard
Control on the pivoting panel

Easy customization of
the application
Large capacity of the
incoming and internal
distribution compartment

Quality of
the line supply
Rectifier bridge
(12 or 24 pulses)

Compactness and
ease of maintenance
3 inverter phases

Protected motor and cables


Output reactor

Ease of programming and


open communication
PLC
Reliability and ease
of maintenance
Power module (1 inverter phase
with High-Voltage IGBT with DC
capacitors)
Water cooling to compensate for the
room getting warmer (up to 10 MW)
Example of a 6 MW drive

Continuity of operation
Water-cooled system with
redundant pump as standard

Easy customization Compactness Quality of the line supply


of the application and accessibility Rectifier bridge
Large capacity of the Control on the (12 or 24 pulses)
incoming and internal pivoting panel
distribution compart-
ment

Inverters Modularity
1 and 2 Easy to place
inverters in parallel
Ease of programming and
open communication Protected motor
PLC and cables
Output reactor

Reliability and ease


of maintenance
Power module (1 inverter phase
with High-Voltage IGBT with DC
capacitors)
Make your life easier
with complete solutions
Altivar 1000 is open to most networks, and can be integrated in any The Altivar 1000
medium or low-voltage architecture. solution is based
on an assembly of
With the Altivar 1000, Schneider Electric has created a comprehen- a transformer, drive
sive, safe, and consistent offer for: and medium-voltage
electric motor.
Controlling and supplying equipment
Schneider Elec-
Improving performance
tric can provide a
turnkey solution
Schneider Electric, world leader in electrical distribution and control including the drive
systems, presents a range of products, solutions and services for: and associated
Transforming and routing energy equipment (electrical
Automating machines and processes, in complete safety distribution, control
Controlling, supplying and making equipment safe. systems).
For more informa-
tion, please contact
our project teams.

Schneider Electric global Solution offer

Power management
and monitoring

Electric substation

GIS switchboard MV/MV AIS 12 MV


power transformer switchboard

MV motor and drive AIS MV switchboard MV/MV transformer


MV motor starter control

Secondary electric
substation

LV switchboard LV motor control switchboard LV variable speed drive


Ensure the reliability of your installa-
tions with a simple open architecture
An innovative control system which is based on:
- A latest-generation microprocessor board (to ensure quick and
accurate torque and speed control in real time)
- A programmable PLC function for openness to networks and easy
adaptation to the application (electric drive system auxiliaries taken
into account)

Seamless integration into a control system architecture (the PLC


supports the main types of industrial networks) Ease of program-
ming and diagnos-
tics
Advanced control functions that are simple to implement:
The drive has ad-
- Autotune function for safe, quick startup vanced parameter-set-
- Diagnostics and maintenance locally (via terminal or PC) and ting and diagnostic
remotely functions.
It is possible to access
the machine status
with the key values
signature (current, volt-
age, etc. in real time).

Operator
stations
Ethernet
Information
Servers

Fieldbus
Control

PLCs

Equipment

Altivar 1000

Medium-voltage
variable speed drive Medium-voltage
switchboard
Setup and support as benefits
of an international group

We apply our industrialization capacity to Services,


thus guaranteeing your success.

Schneider Electrics expertise

Service experts are on hand to help you:


get maximum return from your investments
optimize the value of your installations throughout their life cycle

A wide range of associated services

Audit and consultancy: Installation


- line supply consultancy (compensation, and startup with:
filtering, harmonics, etc.) - assistance and troubleshooting
- shaft line study (torsional analysis, etc.) - specific maintenance contract
- energy efficiency, so as to determine the (possibly including remote access and
best drive solution reconditioning)

Bespoke project Customized training


management
Speed and flexibility
Factory tests at maximum of service provision
power with or without motor
Make the most
of your energy
Altivar 1000 :
technical specifications
General characteristics

Converter type
Input DFE 12P DFE 24P AFE
12-pulse diode bridge 24-pulse diode bridge Active rectifier (PWM)
Output Neutral point clamped (NPC) 3-level voltage source PWM inverter with IGBT
Input voltage Adapts to any type of medium-voltage network
Variation: standard 10%
Input frequency 50/60 Hz 3% 50/60Hz3% 50/60Hz3%
Power factor > 0.96 > 0.96 > 0.98
Efficiency at nominal power ~ 0.99* ~ 0.99*
Type of motor supplied Asynchronous motor as standard, synchronous motor as an option
Motor connection
3-phase output voltage - Standard: 0 .. 2300 V - 0 .. 3300 V
- Options: 4160 V - 6600 V - 7200 V - 10,000 V - 13,200 V etc
Output frequency Normal: 5 .. 70 Hz, Extended: 5 .. 140 Hz
Input transformer - External, oil type or dry type (no limit on distance)
- Integrated in the converter, dry type only
Auxiliary voltage 400 V 3-phase, 50 Hz 460 V 3-phase, 60 Hz
230 V single-phase, 50 Hz (UPS)
Protection index - air cooling: IP41
- water cooling: IP41 and IP54 as an option
Safety system Grounding of DC bus, locking system
Paintwork RAL 7035 (standard)
Cooling - air with redundant fan for power 5200 kVA
- water with redundant pump for power 14,400 kVA
Reference standards IEC EN 61800-3, IEC EN 61800-4, IEC EN 61800-5-1, IEC EN 60204-11, IEC EN 60529
Standards Others as an option
European directives 98/37/EC and amendments, 89/336/EEC and amendments

Control characteristics

Motor control modes V/f type control, sensorless flux vector control, flux vector control with speed sensor.
Catch on the fly, master/slave functions, autotuning, suppression of critical speeds
Number of quadrants 2 2 4
Steady state operation Speed accuracy in steady state:
0.05% with speed sensor; 0.05% without speed sensor
Dynamic operation Response time in torque control mode: 5 ms
Protection Overcurrent, overload, overvoltage, voltage dip, ground fault, jammed motor, etc.
Interface - Graphic keypad for local operation
- Wired and networked remote communication
Communication Standard: Ethernet, Profibus, Modbus
Options: CANopen, DeviceNet, etc.

* Drive without transformer


Environmental characteristics

Storage temperature - 20 .. + 70C


Operating temperature +5 .. + 40C. Operation possible up to + 50C. In this case, derating of 2% per degree Celsius
above 40C.
Cooling method A33 series: air cooling
W33 series: water cooling
Heat exchanger Internal water-water exchanger
(W33 series only) External air-water exchanger (option)
Cooling liquid
temperature Input: + 5 .. + 35C
(W33 series only) Output max. + 40C
Relative humidity < 95%, without condensation
Altitude < 1000 m above sea-level
Vibration 3M1 class in accordance with standard IEC 721-3-3:
Movement: 0.3 mm over a range between 2 and 9 Hz
Acceleration: 1m/s2 over a range between 2 and 9 Hz
Noise level Air cooling: 80 dB(A)
Water cooling: 70 dB(A)

Options

Braking by chopper and resistor


Input isolation switch with grounding
Output isolation switch with grounding
IP54 (water cooling)
Output sinus filter (for retrofitting)
External airwater exchanger
Inverter + battery charger
Drive for several motors for connection to the network (by-pass)
Other standards and certifications: NEMA/ANSI, UL, CSA, DNV, GOST, etc.

Identification code
DFE: Input diode bridge
ATV1000_xx y 33 zzz AFE: Active input bridge (PWM)
12P: 12-Pulse
24P: 24-Pulse
Name of Nominal Cooling Output voltage Input bridge
range power 33: 3300 V
(kVA) DFE 12 P
A (air) DFE 24 P
W (eau) AFE
Examples : - ATV1000_3K6 A33 12P
- ATV1000_10K8 W33 AFE
A33 series: air cooled 3300V

References Service class* Dimensions and weight

(according to standard IEC 146-1- 3.10.3.5) L x D x H (mm)


With 10% overload Weight (kg)

IN (ARMS) AN (kVA) PM (kW) DFE AFE


ATV1000 - 1k3 220 1260 1100
2000 x 1000 x 3125 (FA1) 3800 x 1000 x 3125
ATV1000 - 1k8 320 1830 1600
2800 6500
ATV1000 - 2k6 450 2570 2250
ATV1000 - 3k6 640 3660 3200 3400 x 1000 x 3125 (FA2) 7600 x 1000 x 3125
ATV1000 - 5k2 900 5140 4500 5200 12000
* Other overload possible: please contact us.

Typical dimensions for DFE converters


FA1 FA2
815

815

Control Control
3125

3125
2300

2300

Aux. Aux.
10

10

600 1400 1000 600 1400 1400 1000


2000 3400

Note
The dimensions refer to the standard configuration.
The values for the power on the motor shaft PM are given for a power factor of 0.9 and motor efficiency of 0.97.
They should be adapted to each application.
The nominal power without overload is higher than that in the above table.
The values given are for a motor frequency of 70 Hz maximum.
For higher frequencies: please contact us.
W33 series: water cooled 3300V

References Service class* Dimensions

(according to standard IEC 146-1-1 3.10.3.5) L x D x H (mm)


With 10% overload

IN (ARMS) AN (kVA) PM (kW) DFE AFE


ATV1000 - 1k6 260 1490 1300
2800 x 1000 x 2310 (FW1) 5200 x 1200 x 2310 (FW6)
ATV1000 - 2k4 390 2230 1950
2400 4800
ATV1000 - 3k6 580 3320 2900
4400 x 1000 x 2310 (FW2)
ATV1000 - 4k8 780 4460 3890
3850 7800 x 1200 x 2310 (FW7)
4600 x 1000 x 3125 (FW3) 7600
ATV1000 - 7k2 1160 6630 5790
3950

ATV1000 - 10k8 1740 9950 8680 6200 x 1000 x 2310 (FW4) 10400 x 1200 x 2310 (FW8)
5150 9800
ATV1000 - 14k4 2320 13260 11570 9000 x 1200 x 2310 (FW5) 13200 x 1200 x 2310 (FW9)
7400 12000
* Other overload possible: please contact us.

Typical dimensions for DFE converters


FW1

Control
2300

2310

Aux.
10

600 1400 800 1000


2800

FW2

Control
2300

2310

Aux.
10

600 1400 1400 1000 1000


4400
Typical dimensions for DFE converters
(Water cooled 3300V)

FW3

Control
2300

2310
Aux.

800 1400 1400 1000 10 1000


4600

FW4

Control
2300

2310

Aux.
10

1000 1400 1400 1400 1000 1000


6200

FW5
2300

2310
10

1000 1400 1400 1600 1400 1400 1000 1000


9000
Prepare your quote
Date Name Phone
Company Position/Organization E-mail
Project name Country
Market segment Water & Wastewater Oil & Gas Power generation Mining & Minerals Metals
Other
Application Pump Fan Compressor Extruder Other
End user EPC OEM SI
Standars & Certifications IEC ANSI IEE UL Other
Customer specifications
Project status Budget estimate RFQ phase
Purchasing time frame less than 6 months between 6 & 12 months between 12 & 18 months more than 18 months
Other informationScope of supply
Scope of supply
Quantity of MV drives
Scope of supply Drive Input transformer
Input switch/breaker Output switch/breaker By-pass
Motor Other
Supply data
Power supply Voltage kV % Frequency Hz %
Short circuit power (MVA) max: min: HV cable length
Auxiliary supply Voltage V % Frequency Hz %
Control supply UPS (Y/N) No. of phases V Hz
Motor parameters
Type of motor Induction Synchronous New Existing (retrofit)
Rated power kW hp Number of poles
Maximum power kW hp
Rated speed rpm Maximum speed rpm
Rated frequency Hz Efficiency % Power factor pu
Rated current A DOL starting current A
Maximum torque % Inertia J (GD2/4) kgm2
Excitation current A Excitation voltage V
Ventilation Self-ventilated Force-ventilated
Load parameters
Type of load Variable torque Constant torque Constant power Other
Breakaway torque (at 0 rpm) kNm pu
Gear Reduction ratio Inertia J (GD2/4) kgm2
Starting time
Overtorque 110% 60 s every 10 min. 150% 60 s every 10 min. Other
Acceleration time Deceleration time
Braking Regenerative Resistance Braking power kW Cycle
Reverse speed
Installation
Temperature (C) Indoor: min. max. Outdoor: min. max.
Relative humidity Altitude less than 1000 m Other
Drive Indoor Outdoor Inside container Rectifier 12-pulse input 24-pulse input Other
Air cooling Water cooling
Input transformer Dry type Oil filled Indoor Outdoor P 00 IP54 Other
Distance Transformer to drive Drive to motor
Interface
No. of analog inputs 24 VDC 4~20mA No. of analog outputs 24V VDC 4~20mA
No. of digital inputs No. of digital outputs Dry contact
Communication Ethernet Modbus Profibus DeviceNet Other


DIA2ED1080701EN - Imprimierie xxx

Schneider Electric Industries S.A.S.

Head Office Due to possible changes in standards and equipment, the features described in this document
89, Bd Franklin Roosevelt in the form of text and images are subject to confirmation by Schneider Electric.
92504 Rueil-Malmaison Designed and created by: Gavrinis
FRANCE Photos: Schneider Electric - Shutterstock

www.schneider-electric.com
www.telemecanique.com
ART : 834977 Date : 07/2008

You might also like