Series TY-B 80 and 115 K-factor


Conventional Sprinklers
Special Response, Standard Coverage
General Sprinkler
Description Identification
The Series TY-B, 80 and 115 K-factor,
Conventional Sprinklers described in
Numbers (SINs)
this data sheet are special response - TY3641 Conventional 80K
standard coverage, decorative 4 mm
glass bulb sprinklers designed for use TY4641 Conventional 115K
in accordance with the installation rules
recognized by the applicable Approval
agency (e.g., VdS). These sprinklers are
Technical
intended to be installed either pendent
or upright, and in either position, they
Data
produce a spherical water discharge Approvals
pattern with approximately 50% of
the discharge directed upwards and
VdS Approved (CEA 4001)
Operation
approximately 50% of the discharge Maximum Working Pressure
directed downwards. 12,1 bar The glass bulb contains a fluid which
expands when exposed to heat. When
Discharge Coefficient the rated temperature is reached, the
NOTICE fluid expands sufficiently to shatter the
K = 80 lpm/bar1/2
The Series TY-B Sprinklers described K = 115 lpm/bar1/2 glass bulb, allowing the sprinkler to acti-
herein must be installed and maintained vate and water to flow.
in compliance with this document, as Temperature Ratings
well as with the applicable standards
recognized by the Approval agency, in
57C, 68C, 79C, 93C, and 141C
Finishes
Installation
addition to the standards of any other
Refer to Table A. The Series TY-B Sprinklers must
authorities having jurisdiction. Failure
be installed in accordance with this
to do so may impair the performance
of these devices. Physical Characteristics section.
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bronze
Button . . . . . . . . . . . . . . . . . . . . . . Brass/Copper General Instructions
The owner is responsible for maintain- Sealing Assembly Beryllium
ing their fire protection system and Nickel w/TEFLON Do not install any bulb type sprinkler
devices in proper operating condi- Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glass if the bulb is cracked or there is a loss
Compression Screw Bronze of liquid from the bulb. With the sprin-
tion. Contact the installing contrac- Deflector . . . . . . . . . . . . . . . . . . . . . . . . . Copper
tor or product manufacturer with any kler held horizontally, a small air bubble
questions. should be present. The diameter of the
air bubble is approximately 1,6 mm for
the 57C to 2,4 mm for the 141C tem-
perature ratings.
A leak tight 1/2 inch NPT sprinkler joint
should be obtained with a torque of
9 to 19 Nm. A leak tight 3/4 inch NPT
sprinkler joint should be obtained with
a torque of 13 to 27 Nm. Higher levels
IMPORTANT of torque may distort the sprinkler inlet
Always refer to Technical Data and cause leakage or impairment of the
Sheet TFP700 for the INSTALLER sprinkler.
WARNING that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.

Page 1 of 4 FEBRUARY 2015 TFP663


TFP663
Page 2 of 4

* Temperature rating is ** Pipe thread connections per Components:


indicated on Deflector ISO 7-1 can be provided on 1 - Frame 4 - Bulb
or adjacent to orifice special request. 2 - Button 5 - Compression
seat on Frame. 3 - Sealing Screw
Assembly 6 - Deflector *

11 mm 13 mm
NOMINAL NOMINAL
1/2" ** MAKE-IN 3/4" ** MAKE-IN
NPT NPT
6* 6*

5 5
56 mm 57 mm
4 4

2 2
38 mm 38 mm
3 3
WRENCH WRENCH
FLATS FLATS
1 1

SHOWN CROSS SECTION SHOWN CROSS SECTION


PENDENT SHOWN UPRIGHT PENDENT SHOWN UPRIGHT
FIGURE 1
SPECIAL RESPONSE SERIES TY-B CONVENTIONAL SPRINKLERS

Do not attempt to make up for insuf- Sprinklers that are found to be leaking
ficient adjustment in the escutcheon or exhibiting visible signs of corrosion
plate by under- or over-tightening the must be replaced.
sprinkler. Readjust the position of the Automatic sprinklers must never be WRENCH RECESS
sprinkler fitting to suit. painted, plated, coated or other- (END "A" USED FOR
The Series TY-B Conventional Sprin- wise altered after leaving the factory. 1/2" NPT MODELS)
klers must be installed in accordance Modified sprinklers must be replaced.
with the following instructions. Sprinklers that have been exposed to
corrosive products of combustion, but
Step 1. With pipe thread sealant WRENCH RECESS
have not operated, should be replaced
applied to the pipe threads, hand (END "B" USED FOR
if they cannot be completely cleaned
tighten the sprinkler into the sprinkler 3/4" NPT MODELS)
by wiping the sprinkler with a cloth or
fitting.
by brushing it with a soft bristle brush. FIGURE 2
Step 2. Tighten the sprinkler into the W-TYPE 6
Care must be exercised to avoid
sprinkler fitting using only the W-Type SPRINKLER WRENCH
damage to the sprinklers before,
6 Sprinkler Wrench (Ref. Figure 2)
during, and after installation. Sprin-
or W-Type 7 Sprinkler Wrench (Ref.
klers damaged by dropping, striking, WRENCH
Figure 3). With reference to Figure 1, the
wrench twist/slippage, or the like, must RECESS
W-Type 6 or W-Type 7 Sprinkler Wrench
be replaced. Also, replace any sprin-
is to be applied to the wrench flats.
kler that has a cracked bulb or that has
lost liquid from its bulb. (Ref. Installa-
Care and tion Section).

Maintenance The owner is responsible for the inspec-


tion, testing, and maintenance of their
The Series TY-B Sprinklers must be fire protection system and devices in
maintained and serviced in accordance compliance with this document, as well
with this section. as with the applicable standards of the PUSH WRENCH
National Fire Protection Association IN TO ENSURE
Before closing a fire protection system (e.g., NFPA 25), in addition to the stan- ENGAGEMENT
main control valve for maintenance dards of any other authorities having WITH SPRINKLER
work on the fire protection system that jurisdiction. Contact the installing con- WRENCHING AREA
it controls, permission to shut down the tractor or product manufacturer with
affected fire protection system must be FIGURE 3
any questions. W-TYPE 7
obtained from the proper authorities
and all personnel who may be affected It is recommended that automatic SPRINKLER WRENCH
by this action must be notified. sprinkler systems be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
TFP663
Page 3 of 4

P/N 57 - XXX - X - XXX

SIN SPRINKLER TEMPERATURE


FINISH RATING
473 80K CONVENTIONAL (1/2 NPT) TY3641
1 NATURAL BRASS 135 57C
493 115K CONVENTIONAL (3/4 NPT) TY4641
PURE WHITE (RAL9010)* 155 68C
3 POLYESTER
175 79C
SIGNAL WHITE (RAL9003)
4 200 93C
POLYESTER
9 CHROME PLATED 286 141C

* Eastern Hemisphere sales only

TABLE A
SERIES TY-B SPECIAL RESPONSE CONVENTIONAL SPRINKLERS
PART NUMBER SELECTION

Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.

Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and Part Number
(P/N).
Sprinkler Assembly
Specify: (Specify SIN), Series Special
Response TY-B Conventional Sprinkler,
(specify) K-factor, (specify) temperature
rating, (specify) finish, P/N (specify from
Table A)
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
TFP663