AASHTO LRFD Bridge 2007 Dizayn Kriterlerine Dayal Menfez Hesab (SI Birim Sistemi)
YER: TASARIMCI: TARH 4/11/2017
N ADI: PROJE ADI: REVZE
DEERLER GRNZ
Beton Dayanm snf, fck 25 MPa
Seilen Donat ap 12 mm
st Tabliye
Hareketli (Tat) Yk (HS 20 AASHTO Truck)
Dolgu zeri.Har.Yk (hf< 2400mm ise) hf = 600 mm LL dikkate alnr. Tasarm Kural (AASHTO 3.6.1.
Yayl Yk Uzunluu (Akla Dik Dor.) 3510 mm Edeer Teker Yk Etkir (AASHTO 3.6.1.
IM = 33(1 - 0.00041 hf) > 0% 24.88 % Hareketli Yk Etkisi (Impact Factor Nedeni ile artar)
Arttrlm Hareketli Yk 72.83 KN/m
rarj Yk ( Ek lYk)
Menfez zeri Yayl Ek Yk (Dolgu hari) 0 KN/m
z Arlk
st Tabliye Arl (Lineer yayl Yk ) 8.75 KN/m
Cidar
Zemin basnc
kah = (1 - sinf ) / (1 + sinf ) 0.333
Dolgu rarj Balang Deeri 10.8 KPa
Dolgu rarj ykseklii (h' = s / gs ) 0.6 m
Cidar Alt Noktas lineer Yk deeri 12.6 kN/m
z Arlk
Toplam Cidar Arl = tw (H - tbs - tts) gc 14.0 KN
Radye
Btn Menfezin Arl
niform zemin altndaki gerilme Deeri 51.63333 kN/m Bknz Not:1
YKLEME ARPANLARI
l Yk Katsaylar 1.25 (AASHTO 3.4.1)
24.44 127.46
5.40 5.40
18.9 18.9
64.541667 127.46
YAPI ANALZ
Yapnn analizinde Hardy Cross Yntemi (moment datmlar) kullanlmtr. Menfez, statik hesabnda ereve kabul edilmi
Yklerden dolay oluan Ankastrelik Momentleri Sperpoze edilerek Dm Noktalar u momentleri Hesab yaplmtr.
Dm Noktas A B D C
Eleman-ubuk AC AB BA BD DB DC CD CA
Uzunluk 0.80 0.60 0.60 0.80 0.80 0.60 0.60 0.80
Atalet Momenti 0.0292 0.0292 0.0292 0.0292 0.0292 0.0292 0.0292 0.0292
Hesap Faktr 0.43 0.57 0.57 0.43 0.43 0.57 0.57 0.43
FEM 0.58 -4.56 4.56 -0.58 0.72 -5.76 5.76 -0.72
Datma 1.71 2.27 -2.27 -1.71 2.16 2.88 -2.88 -2.16
Devir -1.08 -1.14 1.14 1.08 -0.85 -1.44 1.44 0.85
Datma 0.95 1.27 -1.27 -0.95 0.98 1.31 -1.31 -0.98
Devir -0.49 -0.63 0.63 0.49 -0.48 -0.66 0.66 0.48
Datma 0.48 0.64 -0.64 -0.48 0.48 0.65 -0.65 -0.48
Devir -0.24 -0.32 0.32 0.24 -0.24 -0.32 0.32 0.24
Datma 0.24 0.32 -0.32 -0.24 0.24 0.32 -0.32 -0.24
Devir -0.12 -0.16 0.16 0.12 -0.12 -0.16 0.16 0.12
Datma 0.12 0.16 -0.16 -0.12 0.12 0.16 -0.16 -0.12
Devir -0.06 -0.08 0.08 0.06 -0.06 -0.08 0.08 0.06
Datma 0.06 0.08 -0.08 -0.06 0.06 0.08 -0.08 -0.06
Devir -0.03 -0.04 0.04 0.03 -0.03 -0.04 0.04 0.03
Datma 0.03 0.04 -0.04 -0.03 0.03 0.04 -0.04 -0.03
5.0
4.0
Moment (kN-m)
Mmax (+) 4.69 kN/m 3.0
2.0
Mmax (-) -2.14 kN/m
1.0
0.0
Md
0.39
0
0.03
0.06
0.09
0.12
0.15
0.18
0.21
0.24
0.27
0.3
0.33
0.36
0.42
0.45
0.48
0.51
0.54
0.57
0.6
4.69 kN/m -1.0
-2.0
-3.0
mesafe x (m)
40.0
0.39
0.42
0.6
0
0.03
0.06
0.09
0.12
0.15
0.18
0.21
0.24
0.27
0.3
0.33
0.36
0.45
0.48
0.51
0.54
0.57
-20.0
Vd 49.37 kN
-40.0
Balant yerinden d Mesafesi kadar uzakta
-60.0
mesafe x (m)
RADYE
2.0
Mmax (+) 3.02 kN/m
Moment (kN-m)
0.0
Mmax (-) -5.62 kN/m
0.39
0
0.03
0.06
0.09
0.12
0.15
0.18
0.21
0.24
0.27
0.3
0.33
0.36
0.42
0.45
0.48
0.51
0.54
0.57
0.6
-2.0
-6.0
-8.0
mesafe x (m)
60.0
0.0
0.39
0.42
0.6
0
0.03
0.06
0.09
0.12
0.15
0.18
0.21
0.24
0.27
0.3
0.33
0.36
0.45
0.48
0.51
0.54
0.57
-20.0
Vd 62.40 kN
-40.0
Balant yerinden d Mesafesi kadar uzakta
-60.0
-80.0
mesafe x (m)
-60.0
-80.0
mesafe x (m)
CDARLAR
3.0
Mmax (+)
Moment (kN-m)
3.02 kN/m 2.0
0.0
Md 3.02 kN/m
0.52
0
0.04
0.08
0.12
0.16
0.2
0.24
0.28
0.32
0.36
0.4
0.44
0.48
0.56
0.6
0.64
0.68
0.72
0.76
0.8
-1.0
-2.0
mesafe x (m)
0.04
0.28
0
0.08
0.12
0.16
0.2
0.24
0.32
0.36
0.4
0.44
0.48
0.52
0.56
0.6
0.64
0.68
0.72
0.76
0.8
-1.0
-2.0
-3.0
Shear (kN)
-5.0
Vmax (-) -8.25 kN
-6.0
-7.0
Vd 7.52 kN -8.0
mesafe x (m)
KESME KONTROL
Beton Kesme Dayanm = fVc = f0.17 (f'c)0.5 bw d (ACI 11.2.1.2)
BETONARME HESAPLARI
Minimum betonarme donat oran, min 0.0007 Bknz Not:2 (AASHTO 5.10.8
Minimum betonarme scaklk ve rtre donat oran, min 0.0007 Bknz Not:2 (AASHTO 5.10.8
Maksimum donat aral (donat merkezlerinden), s max 525 mm Maks (1.5 t, 450) (AASHTO 5.10.3
1- Gerekte, Radyedeki zemin gerilmesi niform olmayacaktr. Yinede kolaylk salamak amacyla niform kabul edilmitir.
2- Minimum Betonarme donat oran tek sra deerine gre verilmitir. Eer ift sra koyulacaksa iki ile arplmas gerekir.
3- ki sra donat arasndaki aralk 150mm den fazla 25mm den az olamaz.
4- Zeminin Doygun olduu kabul edilmitir.
5-Menfezin zerine sadece bir dingilin gelecei varsaylmtr. Bu varsaym 4300 mm ye kadar dorudur.Geniliin daha fazla olduu menfez tiplerinde
iki dingil bineceinden bu hesaplar kullanlmayacaktr.
TU MENFEZ STATK HESABI
n Kriterlerine Dayal Menfez Hesab (SI Birim Sistemi)
4/11/2017
Version 1.0
(AASHTO 3.6.1.2.6)
(AASHTO 3.6.1.1.2)
(AASHTO 3.6.1.2.6)
(AASHTO 3.6.1.2.6)
(AASHTO 3.6.2.2)
(AASHTO 3.4.1)
(AASHTO 3.4.1)
(AASHTO 3.4.1)
mesafe x (m)
mesafe x (m)
0.33 0.33
mesafe x (m)
mesafe x (m)
0.33 0.33
0.36 0.36
0.36 0.36
0.42 0.42
0.42 0.42
0.45 0.45
0.45 0.45
0.48 0.48
0.48 0.48
0.51 0.51
0.51 0.51
0.54 0.54
0.54 0.54
0.57 0.57
0.57 0.57
0.52
0.08
0.12
0.16
0.2
0.24
0.28
0.32
0.36
0.4
0.44
0.48
0.56
0.6
0.64
0.68
0.72
0.76
0.8
mesafe x (m)
0.12
0.16
0.2
0.24
0.32
0.36
0.4
0.44
0.48
0.52
0.56
0.6
0.64
0.68
0.72
0.76
0.8
mesafe x (m)
(ACI 11.2.1.2)
(AASHTO 5.10.8)
(AASHTO 5.10.8)
(AASHTO 5.10.3.2)
rsaym 4300 mm ye kadar dorudur.Geniliin daha fazla olduu menfez tiplerinde