lOO WATT MERCURY VAPOR

@ vgoot - M3641

M3601 M3641
EXTRUDED LOW BRIGHTNESS EXTRUDED LOW BRIGHTNESS
BAFFLE FINISHED IN 3M BAFFLE FINISHED IN 3M
NEXTEL BLACK NEXTEL BLACK

Surface Pendant
Design Cylinder Length Design Cylinder Length
Numbel Size o.A. Lamping Number Size o.A. Lamping
t\,13601 8" x 161/," 1612" 100w. R40 M3641 8" x 16Y2" 6',0" 100w. R40

Specify Voltage Required

Conslruclion: Finish:
Housings are constructed of heavy gauge aluminum Standard finish is #313 Duranodic Bronze Baked
Enamel over chromate dip. Black, white, and satin
extruded material of corrosion resistant alloy with a
1/8" wall th ic kness. aluminum are also available. See price list.
Pendants are supplied six leet o.a. with stem, Ballast Type:
canopies, and alignment swjvels. Constant wattage core and coil high power factor
Socket and Wiring: autotransformer, easily accessible for service.
Fixture is wired with 200'C. SF2 Silicone wire and Labels:
n ickel-plated screw shell socket. Underwriters' listed, LB.E.W.

o copynicHT ocr. 1975, N L CO RPORATION . 14901 BRoADWAy, cLEVELAND. oHre 44i 37


Certified Tesl Repon No. ERL 1392
NL CoIp. Becessed Oownlight, Cat. No, 3101
One GE H100RFL38-4 100W Reflector Mercury Lamp,
Rated 2850 Lumens

Average Luminance Dala Luminance Summary-Footlamberts


Footlamberts Angle Average FL
Angle Luminance 45 1549
0 1 8266 50 814
30 a229 55 344
40 2762 60 171
Total Lumens
45 1549 650
50 814 700 Zone Lumens Percenl
e0 55 344 75 0 0-40 1323 46.44
60 171 80 0 0-60 1440 50.55
650 85 0 0-90 1442 50.63
700
750
800 Certified Test Report No. ERL 1392
850 NL Corp. Recessed Downlight, Cat. No.3101
one GE H1ooRFL38-4100w R40 Mercury Lamp, Rated 2850 Lumens
Coeflicients Ol Ulilizalion
Etfective Floor Cavity Rellectance = .20
cc 80 70 50 30 0
Wall 70 s0 30 10 70 50 30 t0 50 30 l0 50 30 10 50 30 10 0
RCR
1 .58 .57 .56 .55 .57 .56 .55 .54 .54 .53 .52 .52 .51 .51 .50 50 .49 .48
2 .56 .54 .52 .51 .55 .53 .51 .50 .51 .50 .49 .50 .49 .48 .49 .48 47 .46
3 .54 .51 .49 .47 .53 .50 .48 .47 .49 .47 .46 .48 .47 .45 .47 .46 .45 .44
4 .52 .48 .46 .44 .51 .48 .46 .44 .47 .45 .44 .46 .44 .43 .45 .44 .43 .42
5 .49 .46 .43 .42 .49 .45 .43 .41 .45 .43 .41 .44 .42 .41 .43 .42 40 40
6 .48 .44 .41 .40 .47 .43 .41 .39 .43 .41 .39 .42 .40 .39 .41 .40 39 38
7 .45 .42 .39 .37 .45 .41 .39 .37 .41 .38 .37 .40 .38 .37 .40 .38 .36 36
B .44 .39 .37 .35 .43 .39 .37 .3s .39 .36 .3s .38 .36 .3s .38 .36 .35 34
I .42 .38 .35 .33 .41 .37 .35 .33 .37 .35 .33 .36 .34 .33 .36 34 .33 .32
S/MH : .B 10 40 .36 .33 .31 .39 .35 .33 .31 .35 .33 .31 .35 .33 .31 .34 .32 .31 .30
MED. SPREAD

Number ol Luminaires Required lor 30.0 and 70.0 FC. Candlepower Oata Candlepower Summary
Angle Candlepower Lumens Angle Average CP
Lighl Loss Factor = .75
- See Foolnote
CC, Wall + FC Reflectances: 80, 50, 20 0 184s 0 1845
Work Plane Heiqht = 2.5 Feet 5 1845 173 5 1 845
10 1704 10 1704
Room 30.0 Fooicandles 70.0 Footcandles 1541 426 15 1541
Dimensions Height Height 20 1224 20 1228
WL 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 983 453 25 983
20 20 11 11 12 13 26 27 29 31 30 720 30 720
20 30 16 17 18 19 38 39 41 44 35 399 272 35 399
20 4A 21 22 23 24 49 51 54 57 40 214 40 214
20 60 31 32 34 36 73 75 79 83 45 110 94 45 110

30 20 16 17 18 19 38 39 41 44 50 53 50 53

30 30 23 24 25 55 56 59 62 55 20 23 55 20

30 40 31 32 33
27
35 72 74 77 81 609 60 I
30 60 46 47 49 51 106 109 113 118 65 o2 65 0
70 0 70 0
30 B0 60 62 64 66 141 144 149 155
75 00 75 0
40 20 21 22 23 24 49 51 54 57 80 0 80 0
40 30 31 32 33 35 72 74 77 A1 85 00 85 0
40 40 41 41 43 45 95 97 101 105 90 0
40 60 60 6'1 63 65 140 142 147 153
40 80 79 81 83 86 185 188 1S4 200 Total Output
40 100 99 100 103 106 231 234 241 248 Zone Lumens Percent
60 30 46 47 49 51 106 109 113 118 0-40 1323 46.44
60 40 60 61 63 65 140 142 147 153 0-60 1MO s0.55
60 60 89 90 93 95 207 210 216 222 0-70 \ 442 50.63
60 80 120 119 122 125 2ao 27a 244 291 0-90 1442 50.63
60 100 151 148 151 155 353 345 353 361 40-90 119 4.14
100 40 99 100 103 106 231 234 241 248 60-90 2 .08
100 60 1 51 144 151 1 55 353 345 353 361 70-90 0 0.00
100 B0 204 201 199 203 477 46a 465 474 90-180 0 0.00
100 100 25A 253 247 251 601 591 577 586 0-180 1442 50.63

For oiher light loss factors: Tested in Accordance with IES procedLlres
M No. of luminaires required: No. irom table X.75lNew LLF Test distance exceeds 25 feet.