A new concept in Nothing protects quite like Piller

UPS Technology to revolutionize


power protection within Data Centers piller.com
Introducing the Piller Critical Power Module
The Piller CPM (Critical Power Module) has been designed with the specific needs of the modern enterprise data center
in mind, allowing designers to radically change their thinking for the provision of continuous power conditioning.

In a typical data center, a significant proportion protection combined with exceptional efficiency with minimal on-site commissioning and testing. straightforward than a solution with batteries
of power entering the building is lost on power as high as 98%* and even higher efficiencies in and requires little in the way of site preparation.
conditioning, cooling and distribution before it ECO mode. MINIMIZED SERVICE
reaches the IT load. These losses become The Piller CPM has a very low-level maintenance S O F T W A R E T E C H N O LO GY
Efficiency improvements run throughout this A fully controllable and highly responsive power
compounded and have a major effect on regime compared with other systems. There
design, however by integrating the energy store stage and energy store allows operation of the
financial performance: Reducing UPS losses are no battery inspections or autonomy tests
and utilizing innovative cooling techniques, the CPM to be optimized by algorithm according
delivers a wider impact on overall losses. to perform and major maintenance intervals
CPM benefits from wide environmental operating to pre-selection or auto-sensing. Further
are much longer than for most other systems.
Construction and infrastructure costs are a characteristics that allow the elimination of air enhancement of low load efficiency is possible
No substantial work is necessary within the
significant part of the funding cycle for new conditioning used in conventional battery systems. in multi-module systems by use of Enhanced
first 10 years of service.
data centers and the more complex the building For cooling of the unit itself, the designer can Redundancy Mode (ERM) which optimizes the
project, the longer the construction time further choose between white space installation where I N N O VAT I V E C O O L I N G number of units running whilst maintaining
adding to the capital burden. use of the IT cooling system can be made and Key elements of the CPM system are cooled by a required redundancy levels.
traditional plant room installation.
A product that can positively address both self-contained heat exchange system that removes
C O M M U N I C AT I O N S A N D
capital and operating expenditure for a data heat at the component surface more efficiently
SPACE SAVING M O N I TO R I N G
center will make a significant difference to the and effectively than conventional air cooling.
By replacing batteries with an integrated energy In addition to all of the latest communication
total cost of ownership. protocols and interfaces you might expect
store, up to 75% of the space normally taken
MODULAR/SCALABLE
up can be saved. Additional building space for from Piller, the CPM comes complete with the
E N E R GY S AV I N G CPM units can be configured in a variety of
battery air conditioning, switchgear and cabling option to install an Android or iOS App that
The CPM concept brings together a highly different ways even within the same data
is also eliminated. gives authorized personnel an immediate and
efficient and reliable energy store with multiple center and systems of units can be extended mobile status report for any CPM system
mode uninterruptible power system. There The units can be mounted with power distribution to meet the increase in data center loads with anywhere in the world.**
are principle modes providing real power units on pre-assembled skids for rapid deployment time. Scaling up the CPM system is more

*480V 60Hz without DC store. ** Subject to network coverage and


security settings. iOS is a registered trademark of the Apple Corp.
PILLER CPM 300/360
n Reduced Real Estate Requirements
n Increased net IT floor space
n Low service intervention and costs
n Increased availability by simplification
n Several operating modes
n Rapid deployment
n Reduced ancillary assets
n Increased critical power density
n Lower losses overall
n Guaranteed GenSet partnership
n Multiple power configurations
n Efficiency without compromise

~ VI Conditioning Path

~
~ =
K E Y DATA
= ~
O P E R AT I N G M O D E S LOAD

Voltage 380V-480V Mains Generator Frequency Voltage Suppression = VFI Conditioning Path

Efficiency up to 99%*
Operation Operation Stabilisation Stabilisation ~
VFI Mode n n n n n
Frequency 50 & 60Hz MAINS DATA CENTER

Dimensions (in) 96,457w x 35,433d x 74,803h VFD Mode n n n


POWERBRIDGE
Power Rating 300/360kW ERM Mode Applies to all Modes 1-4

VFI Voltage & Frequency Independent, ECO Voltage and Frequency Dependent. Piller CPM simplified schematic.
HEADQUARTERS Piller Australia Pty. Ltd. Piller Italia S.r.l. Piller Power Singapore Pte. Ltd.
Piller Group GmbH 2/3 Salisbury Road, Castle Hill, Centro Direzionale Colleoni, 25 International Business Park,
New South Wales 2154, Australia Palazzo Pegaso 3, #01-65/66 German Centre,
Abgunst 24
T: +61 2 9894 1888 Viale Colleoni 25, 20041, Singapore 609916
37520 Osterode E: australia@piller.com Agrate Brianza (MB), Italy T: +65 6562 9100
Germany T: +39 039 689 2735 E: asiapac@piller.com
E: info@piller.com Piller France SAS E: italia@piller.com
Piller UK Ltd.
1 Avenue du Prsident Pompidou,
Piller Iberica S.L.U. Westgate, Phoenix Way, Cirencester,
CS 70073 BAT A,
Paseo de la Habana, 202 Bis Bj, Gloucestershire, GL7 1RY,
F-92508 Rueil-Malmaison Cedex, France
E-28036 Madrid, Spain United Kingdom
T: +33 1 47 21 22 55
T: +34 91 345 86 58 T: +44 1285 657 721
E: france@piller.com
E: spain@piller.com E: uk@piller.com
Piller Germany GmbH & Co. KG Endurance Power Protection Pvt Ltd. Piller USA Inc.
Abgunst 24, 37520 Osterode, DCT 603, 6th Floor, DLF City Court, 45 Wes Warren Drive, Middletown,
Germany Sikanderpur, MG Road, Gurgaon, New York 10941-2047, USA
ROTARY UPS SYSTEMS T: +49 5522 311 0 Haryana-122001, India T: +1 800 597 6937
E: germany@piller.com T: +91 12442 90262 E: usa@piller.com
HYBRID ROTARY UPS SYSTEMS E: india@piller.com
DIESEL ROTARY UPS SYSTEMS
Additional Piller offices in:
STATIC UPS SYSTEMS
AUSTRIA | CANADA | LATIN AMERICA | NETHERLANDS | SHANGHAI : CHINA | SHENZEN : CHINA | SOUTH KOREA | TAIWAN
STATIC TRANSFER SWITCHES
KINETIC ENERGY STORAGE Representatives and Distributors in:
AIRCRAFT GROUND POWER SYSTEMS ALGERIA | ARGENTINA | AUSTRIA | BAHRAIN | BELGIUM | BRAZIL | CANADA | CHILE | CHINA | DENMARK | ESTONIA | FINLAND
FREQUENCY CONVERTERS HONG KONG | HUNGARY | INDONESIA | IRAN | JAPAN | KOREA | LATVIA | LITHUANIA | MALAYSIA | NETHERLANDS | NIGERIA
| NORWAY | PERU | PHILIPPINES | POLAND | ROMANIA | RUSSIA | SERBIA | SLOVENIA | SOUTH AFRICA | SWEDEN |
NAVAL POWER SUPPLIES
SWITZERLAND | SYRIA | TAIWAN | THAILAND | TURKEY | UAE | UKRAINE | USA
SYSTEM INTEGRATION
Nothing protects quite like Piller

piller.com
Piller CPM 300 (US) 06 2016/Issue 1. Due to a policy of continued improvement, we reserve the right to change any specification without prior notice. ERRORS & OMISSIONS EXCEPTED.
Printed on a Manroland R700 press.