Standard Technical Features of BTG System for Supercritical 660/800 MW Thermal Units

ii) The ducting and supporting structure to be designed to take care of future
Guillotine damper to be installed between the two tap offs before
chimney.

6.4.9 Limits of NOx emission


i) The guaranteed maximum NOx emission (thermal as well as fuel) from
the Steam Generator unit shall not exceed 260 grams of NOx per Giga
Joule (GJ) of heat input to the boiler at 6% O2 level for the range of coals
specified or as per MOEFs requirement in this regard (if applicable)
whichever is more stringent.

ii) The above value of NOx shall not be exceeded during the entire operating
range of Steam Generator for the whole range of specified coals.

6.4.10 Capital overhaul of steam generator


The design and materials for various equipments/auxiliaries etc. shall be
selected keeping in view capital overhaul of units once in two (2) years, such
that no major repairs/replacements, requiring shutdown of the unit, are needed
in between the capital overhauls.
6.4.11 Noise level
The equivalent weighted average of sound level for continuously operating
equipment measured at a distance of 1.5 m above floor level in each elevation
and one meter horizontally from the base of any equipments furnished,
expressed in decibel to a reference of 0.0002 microbar, shall not exceed 85
dB(A).
6.4.12 Operational requirement
The Steam Generator(s) shall be designed for the following minimum
operational requirements at all loads and for the specified range of coal(s).

i) Soot blowing frequency As per OEMs


recommendation for
characteristics of the coal
being fired
ii) Preferred mill combination Any combination of mills
(without any restriction)
iii) Max. coal flow unbalances in coal pipes 5.0%
from same mill, from the average
iv) Slagging :
a) Burner Nil
b) In furnace/ash hopper/ water wall areas Nil
v) Maximum permissible reheat spray water 3% of steam flow at
flow with rated steam temperature at reheater outlet
reheater outlet
vi) Maximum gas temperature variation 300C
across furnace width and depth
28