You are on page 1of 74

Pag.

1/63 - 1
- Page 1

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
1
confidetial
8/27/2017/3
5 - 1 -74
- 1 -/35

FOAIE DE CAPT

Denumire proiect: Subsistem de detectie si semnalizare la tentativa de efractie si


agresiune;
Subsistem de control electronic al accesului;
Subsistem de supraveghere cu televiziune in circuit inchis
(TVCI);
Subsistem de intercomunicatii de securitate.
Sistem complex de securitate.
Amplasament: Str. Augustin Bena nr. 1; Oras SEBES; Jud ALBA

Beneficiar: BANCA TRANSILVANIA- Oras SEBES

Nr. proiect: 01.2016

Faza: PT

Revizia: 0

Proiectant de
specialitate
Breazu Ioan

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.2/63 - 2
- Page 2

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
2
confidetial
8/27/2017/3
5 - 2 -74
- 2 -/35

BORDEROU

2. BORDEROUL DOCUMENTATIEI
Tip Tota
Nr. Nr.
PARTE SCRIS coal l
crt. pag.
pag.
1. FOAIE DE CAPT A4 1 1
2. BORDEROUL DOCUMENTAIEI A4 1 2
3. OBIECTUL PROIECTULUI A4 1 3
4. BAZA DE PROIECTARE A4 1 3
5. DESCRIEREA OBIECTIVULUI A4 2 3
5.1 Amplasament i mprejurimi A4 1 3
5.2 Elemente privind construcia A4 1 4
6. DESCRIEREA SOLUTIEI TEHNICE A4 20 4
6.1 Subsistemul de detecie i semnalizare A4 14 4
6.1.1 Generaliti A4 1 4
6.1.2 Structura subsistemului de detecie i semnalizare A4 2 4
6.1.3 Descrierea zonelor protejate A4 1 5
6.1.4 Amplasamentul componentelor A4 1 6
6.1.5 Calculul energetic A4 2 6
6.1.6 Date tehnice de catalog A4 10 7
6.1.7 Jurnal de cabluri A4 2 16
7. ASIGURAREA SERVICE-ULUI A4 1 14
8. CERTIFICATE DE ATESTARE A CALITII PRODUSELOR A4

PARTE DESENATA

Plan parter.
1. A3 1
Sistem alarmare antiefractie
Plan etaj.
2. A3 1
Sistem alarmare antiefractie
Schema monofilara
3. A3 1
Sistem alarmare antiefractie
4. Plan parter. A3 1
5. Sistem control acces.
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.3/63 - 3
- Page 3

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
3
confidetial
8/27/2017/3
5 - 3 -74
- 3 -/35

Plan etaj.
A3 1
Sistem control acces.
.Schema monofilara
6. A3 1
Sistem control acces.
Plan parter.
7. A3 1
Televiziune circuit inchis.
Plan etaj.
8. 1 1
Televiziune circuit inchis.
Schema monofilara
9. A3 1
Televiziune circuit inchis.
Plan cote parter.
10. A3 1
Plan cote etaj.
11. A3 1
Plan de situatie.
12. A3 1
Sistem alarmare antiefractie

4. Baze de proiectare

La baza intocmirii prezentei lucrari au stat:


- Tema de proiectare aferenta cladirii puse la dispozitie de ARTS -BUCURESTI;
planuri si piese scrise;
- Legea nr. 333/2003- privind paza obiectivelor, bunurilor, valorilor si protectia persoanelor;
- HG 301/2012; Normele metodologice de aplicare a prevederilor proiectului legii;
- NP-I7-02- Normativ pentru proiectarea si executia instalatiilor electrice cu tensiuni
pana la 1 kV in c.a si 1.5 kV in c.c.
- Standardele S.R.C.E.I. seria 839;
- Normativul EN 50131 Incadrarea in nivelul de risc al cladirii.
- Normele tehnice privind proiectarea, instalarea, intretinerea si utilizarea sistemelor
de alarma impotriva efractiei;
- Norme i reglementri emise de ctre Comunitatea European (EURO NORM -
EN 5x);
- Normele i standarde BS 5839 Part1, 4/1988 , BS 5445);
- manualele de instalare ale echipamentului editate de productor.
- P118-1999: Normativ de siguranta la foc a constructiei.
- Legea 10/1995 Calitatea in constructii
- Legislatie: H.G. 766/1997 pentru aprobarea unor regulamente privind calitatea n constructii
Standarde de stat :

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.4/63 - 4
- Page 4

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
4
confidetial
8/27/2017/3
5 - 4 -74
- 4 -/35

-SR EN 5013x Sisteme de securitate


-SR CEI 60050 Electrotehnica si Electroenergetica. Semne conventionale.
-SR EN 61082 Instalatii electrice interioare in constructii. Semne conventionale
-SR CEI 839-1-2 Sisteme de alarma
-SR CEI 60189 1:-7/93 Cabluri si conductoare electrice
Toate echipamentele sunt produse sub standardul calitatii ISO 9001;
Compartimentarile din cadrul obiectivului, in care sunt prevazute echipamentele aferente
sistemelor prezentate, se incadreaza din punct de vedere al mediului, conform normativului
NP-I7-02, in categoriile U0 si U1 (simbol international AD1 si AD2).

4.1. Analiza de risc


Cladirile, institutiile publice sau private, alte entitati de interes public, precum si
activitatile social-cultural-economice, pot fi supuse unor actiuni (amenintari) care daca nu sunt
luate in considerare si contracarate prin masuri adecvate, pot duce la evenimente nedorite,
unele cu consecinte foarte grave pentru integritatea fizica si continuitatea lor functionala.
Sistemul de securitate este componenta tehnica a raspunsului la amenintarile si
vulnerabilitatile relevate intr-un obiectiv pentru care se solicita asigurarea protectiei.
In cazul de fata, in procesul de implementare a politicii de securitate este absolut
necesar ca n cadrul instituiei financiare s fie identificate cerinele de securitate ce trebuie s
fie satisfcute, existand trei surse principale:
Prima surs este derivat din evaluarea riscurilor de securitate (analiza de risc) la care
banca este supus. Prin procesul de evaluare a riscurilor, ameninrile la adresa resurselor
instituiei sunt identificate, dup care se stabilete vulnerabilitatea resurselor la riscurile
identificate precum i probabilitatea de concretizare a acestor riscuri n evenimente distructive
nedorite, fiind estimat impactul potenial asupra resurselor instituiei.
A doua surs deriva din necesitatea asigurrii respectrii legilor i normativelor n
vigoare n Romnia i n Uniunea European, ce reglementeaz activitatea instituiilor
financiar-bancare precum i a cerinelor derivate din obligaiile contractuale fa de clienii
i/sau furnizorii de servicii i utiliti.
. A treia surs o constituie un set particular de principii, obiective i cerine (reglementari
interne) pentru procesarea, stocarea i vehicularea informaiilor pe care instituia financiar le-
a dezvoltat ca proces suport pentru operaiile de afaceri .
Necesitatea realizarii unui climat adecvat de siguranta pentru institutiile financiar-
bancare si transporturile de valori apartinand acestora deriva din urmatoarele pericole si
considerente:
sumele importante de bani precum i alte valori considerabile aflate n
posesia sau n pstrarea instituiilor financiar-bancare pot fi puse n pericol
prin sustrageri sau spargeri, prin atacuri informaionale, prin declanarea unui
incendiu ori prin producerea altor catastrofe naturale;

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.5/63 - 5
- Page 5

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
5
confidetial
8/27/2017/3
5 - 5 -74
- 5 -/35

clienii, aflai uneori n numr mare n cldirile instituiei precum i angajaii


instituiilor pot fi pui n pericol de un atac armat, de declanarea unui
incendiu sau de producerea altor catastrofe naturale;
angajaii instituiilor pot deveni victimele unor antaje sau pot fi luai ostatici, n
vederea obinerii unor sume de bani sau a altor valori ori servicii, prin antaj;
att instituiile financiar-bancare n sine, ct i personalul de conducere al
acestora pot fi supui unor atacuri sau pot deveni victimele unor zvonuri
defimtoare;
credibilitatea instituiilor i buna desfurare a serviciilor acestora pot fi
ameninate prin aciuni sau atacuri informaionale ori prin blocarea canalelor,
inclusiv a celor electronice, de realizare a serviciilor sau de comunicare;
pe lng pierderile de valori, n cazul atacurilor informaionale reuite, apar i
pericolele nesesizrii cilor de atac precum i cel al deteriorrii sistemului
informatic propriu sau asociat instituiei ori al distrugerii bazelor de date ale
acestora;
penetrarea msurilor de siguran i falsificarea nscrisurilor de valoare sau a
crilor de credit pot aduce pe lng pierderi valorice imediate i pierderea
ncrederii n instituie, producnd, prin consecine, alte pierderi importante de
valori;
atacurile mpotriva instituiilor financiar-bancare sunt deosebit de
profesioniste, pregtite cu migal i au o multitudine de forme de manifestare
greu de anticipat; se desfoar cu repeziciune, sunt deosebit de violente i
pot pune n pericol att viei omeneti, ct i ntreaga activitate a instituiei
atacate;
de cele mai multe ori, bunurile dobndite n urma atacurilor mpotriva
instituiilor sunt greu de recuperat, iar pierderile cauzate de incendii sau
dezastre sunt adesea irecuperabile.

5. Descrierea obiectivului
5.1. Amplasamentul si imprejurimile.
Cladirea unde urmeaza sa se instaleze sistemul de securitate - subsistem antiefractie,
subsistem control acces, subsistem TVCI si subsistem de comunicatii pentru, este situata in
Sebes; Str. Augustin Bena nr. 1; Jud.Alba la intersectia a doua strazi. Dorin Pavel cu Augustin
Bena,
Aceasta cladire este destinata serviciului financiar-bancar, pentru acordarea de credite
persoanelor fizice si juridice.
Amplasarea obiectivului si vecinatatile sunt aratata in planul de situatie - pl. 6.

5.2.Elemente privind constructia

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.6/63 - 6
- Page 6

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
6
confidetial
8/27/2017/3
5 - 6 -74
- 6 -/35

Spatiul in care se amenajeaza sistemul comlex de securitate; subsistem antiefractie,


subsistem control acces, subsistem TVCI si subsistem de comunicatii pentru BANCA
TRANSILVANIA AGENIA SEBE, este o locatie noua P+E, cu structura din beton armat si
pereti din caramida, situata central, pentru desfasurarea activitatii cu specific - banca.
Locatia se afla amplasata in orasul SEBES, la intersectia strazilor Str. Dorin Pavel si
Str. Augustin Bena, lipita de o cladire de birouri existenta, cu regim de constructie P+E, unde ocupa o
suprafata totala de circa 650m.p.
Accesul pietonal atat pentru public cat si pentru personal se realizeaza prin latura de
sud, printr-o usa dubla realizata din tamplarie metalica si spatii vitrate de mari dimensiuni.
Vecinatatile obiectivului sunt urmatoarele:
-La la nord o grdin proprietate particular, de care este delimitat printr-un gard
realizat din plas bordurat cu h=2,5m, fr supranlare, sprijinit pe stlpi metalici cu profil
ptrat 50x50x2mm montai la fiecare 2,5m. ntre gard i zidul sediului se afl un trotuar pavat
cu pavele decorative
-La est cldire de birouri cu regim de nlime P+4E
-La sud Augustin Bena care este delimitat prin trotuar pentru circulaie pietonal
-La vest Dorin Pavel, care este delimitat prin trotuar pentru circulaie pietonal.
Perimetrul este nchis la extermitatea de nord, pe laturile de est i vest, cu segmente de gard
realizate din plas bordurat cu h=2,5m, fr supranlare, dup cum este reprezentat n plan
parter.
- Accesul pietonal se realizeaz pe latura de sud, din Str. Augustin Bena, printr-o
u dubl, realizat din tmplrie metalic i spaii vitrate de mari dimensiuni;
- Obiectivul este prevzut cu garaj pentru maina de transport valori, cu acces de
pe latura de sud, din Augustin Bena. Garajul este dotat cu o u metalic, cu
rulare sub tavanul garajului, pe ine de ghidare. Ua este automatizat, cu
comand prin telecomand sau cu acionare manual, doar din interior, n caz de
lips tensiune de reea. S-a prevzut o cale de transferare a valorilor ntre garaj
maina de transport valori i casierie, cu ieire din garaj prin ua practicat n
peretele dintre garaj i casierie i cu circulaie doar prin zonele interioare ale
spaiului destinat casieriei;
- Pereii exteriori sunt realizai din crmid cu grosimea de 25cm, sprijinii pe o
structur de rezisten realizat din stlpi i grinzi din beton aramat;
- Etajul este construit pe aceeai structur de rezisten, la care se adaug stlpii
de sprijin pentru terasa circulabil, delimitat de balustrad spre golul de la parter;
- Pereii interiori sunt realizai din zidrie uoar (15cm grosime), cu ui decorative
din tmplrie metalic. Excepie fac zidurile i uile din zona casieriei;
- Spaiile vitrate sunt realizate din tmplrie metalic, cu geamuri termopan i dubl
deschidere. Excepie geamurile de la holul de intrare, de la garajul auto i de
la ghieele de cas;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.7/63 - 7
- Page 7

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
7
confidetial
8/27/2017/3
5 - 7 -74
- 7 -/35

- n birouri se va monta tavan fals casetat, montat pe tije de 50cm, cu excepia


tezaurului i a garajului de valori. Plafonul n zona terasei circulabile de la etaj va
fi acoperit cu tavan fals nevizitabil, montat la 50cm sub plafon;
- nlimea camerelor este de 4m, att la parter ct i la etaj;
5.3 Activitati specifice. Fluxuri de personal
Activitatea desfasurata in obiectiv va fi una specifica unitatilor financiar-bancare, care
includ relatii cu publicul, birou credite, depuneri/ridicari numerar, depozitare si transfer valori,
etc.
Programul de lucru cu publicul este ntre orele 09.00 17.00. Programul de lucru pentru
angajai este ntre orele 08.00 19.00, program acoperit prin decalarea programului anumitor
angajai. Programul de realizare a cureniei este ntre orele 07.00 09.00 i 17.00 19.00 i
se realizeaz sub supravegherea agentului de paz. Paza obiectivului este asigurat n
intervalul 07.00 19.00 de un agent de paz de la firma care asigur i monitorizarea /
intervenia n caz de eveniment. n intervalul 19.00 07.00 paza obiectivului se realizeaz
exclusiv prin intermediul sistemului de securitate .

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.8/63 - 8
- Page 8

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
8
confidetial
8/27/2017/3
5 - 8 -74
- 8 -/35

La parter sunt delimitate urmtoarele spaii:


- Holul de intrare cu dublu rol de windfang i zon pentru operaiuni bancare
automate;
- n holul de intrare este instalat un punct pentru operaiuni n regim Self Banking
dotat cu un bancomat i o staie PC pentru tranzacii On Line. Programul de lucru
al punctului Self Banking este ntre orele 07.00 23.00;
- Alimentarea bancomatului se realizeaz din interiorul biroului IT de ctre
reprezentantul firmei concesionare, doar n prezena unei persoane autorizate din
partea beneficiarului;
- Tot din biroul IT exist o u de acces n sala serverelor, care gzduiete i
echipamentele de comunicaii (telefonice, internet, radio etc.);
- Pentru operaiuni cu numerar sunt prevzute dou ghiee de cas, dotate cu
sertar de transfer monetar;
- Serviciul casierie dispune de urmtoarele spaii, grupate n colul de sud-vest al
parterului:
- tezaur;
- sal de numrare;
- coridor de trecere spre hol parter;
- sal de preluare numerar la transferul ntre banc i maina de transport valori;
- garajul de valori;
- ghieele de cas.
Agentul de paz staioneaz ntro zon situat vizavi de ghieele de cas, fr a avea la
dispoziie un spaiu delimita
La etaj sunt delimitate urmtoarele spaii:
- Birouri conducere, cu biroul secretariat ntre ele;
- Biroul contabilitate;
- 3 birouri ale angajailor;
- Sala de semnare a contractelor;
- Dou birouri de negocieri;
- Un oficiu la dispoziia personalului propriu;
- O sal cu destinaie de arhiv curent, din care se obine accesul i n arhiva pe
termen lung a bncii;
- Pentru personal i clieni sunt disponibile dou grupuri sanitare;
Teras circulabil, protejat cu balustrad spre golul de la parter

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.9/63 - 9
- Page 9

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
9
confidetial
8/27/2017/3
5 - 9 -74
- 9 -/35

Accesul ntre parter i etaj se face pe o scar prevzut cu spaii vitrate pe palierul dintre
cele dou nivele i la etaj.
Amplasarea echipamentelor centrale de monitorizare se face in birou SERVER, pentru
CSE efractie si DVR - TVCI, si a fost stabilita prin proiectul de arhitectura conform cerintei
beneficiarului si este localizata in partea desenata a proiectului, (vezi planurile: plan parter
pl.1, plan etaj pl.2).

6. Descrierea solutiei tehnice


6.1 Subsistem antiefractie
6.1.1 Generalitati
Pentru protectia BANCA TRANSILVANIA contra tentativelor de efractie s-a prevazut o
centrala computerizata de tipul INTEGRA 128, cu 16 zone extensibile la 128, 8 partitii,
producator SATELPolonia, corespunznd EN 50131-3, grad de securitate 3, clasa de mediu 2;
Solutia adoptata pentru realizarea cerintelor date in tema, conforma cu normativul EN
50131, risc asumat de grad 3 (mediu-mare), clasa de mediu 2 (interior general) specific
categoriei din care face parte, are ca element principal o centrala antiefractie cu
microprocesor, programabila, in configuratie de 16 zone (extensibila la 128 zone), la care se
vor conecta restul de componente conform schemei electrice a intregului sistem.
Folosirea unei centrale cu microprocesor cu zone terminate rezistiv (end of line) face
practic imposibila sabotarea electrica a sistemului fara a avea acces la centrala de alarma cu
un cod master sau fara schema electrica de conexiuni. Cunoasterea unui cod de utilizator va
permite doar accesul in zona corespunzatoare dar si in acest caz evenimentul de dezactivare
al zonei va fi monitorizat de catre centrala de alarma prin intermediul tastaturilor de sistem cu
afisaj alphanumeric tip LCD. Toate evenimentele in total 22527 sunt memorate de catre
unitatea centrala iar vizualizarea acestora poate fi facuta usor de la tastatura. Acest lucru
permite o urmarire usoara a modului in care utilizatorii folosesc si isi indeplinesc obligatiile
legate de sistemul de protectie.
Unitatea centrala este amplasata in camera SERVER. Alimentarea cu energie electrica
se realizeaza din tabloul electric general TG (dintr-un circuit dedicat) ce se afla pe peretele
comun acestei camere cu holul clienti parter iar senzorii ce alcatuiesc sistemul de securitate
sunt amplasati in conformitate cu plansele desenate, astfel incat sa protejeze caile de acces si
incaperile .
Fiecarei adrese din sistem ii corespunde o zona fizica din camp (un singur senzor), in
acest fel identificarea alarmelor si a defectelor facandu-se punctual si cu usurinta, deasemena
fiecarei zone din sistem ii va corespunde cate o eticheta (descriptor) cu ajutorul careia sa se
identifice foarte rapid detectorul generator de stare de alarma sau defect.
Conectarea fizica a detectorilor in sistem se va face folosind terminatii dublu end-of-line
pentru monitorizarea corecta atat a starii detectorului cat si a cablului de legatura intre acesta
si unitatea centrala.
Stabilirea zonelor protejate va fi facuta de comun acord cu beneficiarul in functie de
configuratia si cerintele actuale ale acestuia.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.10/63 -
10 - Page 10

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
10
confidetial
8/27/2017/3
5 - 10 -74
- 10 -/35

De asemenea, pentru marirea eficientei sistemului acesta se va imparti in grupuri de


zone cu acelasi specific, numite partitii, ce se vor arma/dezarma in functie de programul de
lucru precum si in functie de protocoalele de securitate ce vor fi stabilite de comun acord intre
beneficiar si compania de paza.
Dupa o analiza riguroasa s-a stabilit un numar de 8 partitii dupa cum urmeaza:
partitia 1 zona Self Banking
partitia 2 birou IT, server si camera ATM
partitia 3 zona casierie, garaj preluare valori
partitia 4 tezaur, sala numarare
partitia 5 restul spatiilor de la parter
partitia 6 zona conducere
partitia 7 arhiva
partitia 8 restul spatiilor de la etaj
In holul de intrare este instalat un punct pentru operatiuni in regim Self Banking dotat cu
un ATM si o statie PC pentru tranzactii online al carui program (07.00 23.00) depaseste pe
cel al bancii. In acest sens solutia de securizare a acestui spatiu foloseste elemente specfice si
anume: protectia volumetrica a spatiului este realizata cu detector de miscare dubla tehnologie
cu anti-masking si antivandal; bancomatul si unitatea PC vor fi prevazute cu detectoare de soc;
senzorul magnetic ce monitorizeaza usa va fi de asemenea antivandal cu tripla polaritate cu
posibilitatea de izolare pentru operaiile de alimentare. De asemenea spatiul mai este prevazut
cu o unitate opto acustica necesara avertizarii clientilor aflati in spatiu ca mai au la dispozitie
un timp limitat pana cand usile se vor bloca electro mecanic iar sistemul de alarma
corespunzator partitiei sa va arma. Persoana cu drept de aces la bancomat va trebui sa
formeze codul de dezactivare la tastatura din holul usei de intrare.
O alta zona cu activitati specifice o constituie zona IT care contine camera serverului in
care este concentrata majoritatea echipamentelor de securitate si comunicatii extrem de
importante in asigurarea monitorizarii implicit a interventiei in caz de eveniment.
In ceea ce priveste compartimentele de casierie trebuie tinut cont de urmatoarele
aspecte: usile de acces in spatiul casieriei sunt usi de siguranta conforme cu SR-EN 1522;
protectia antiglont este obligatorie, astfel ca peretii compartimentului si geamul trebuie sa
respecte SR-EN 1063; din punct de vedere electronic compartimentele vor fi prevazute cu
dispozitive folosite la hold-up, si anume butoane si pedale de panica, de asemenea protectia
volumetrica va fi asigurata de detectoare de miscare dubla tehnologie, anti-masking.
Pentru sala de preluare numerar si garajul pentru masina de transport valori, protectia
spatiilor va fi similara cu a casieriilor iar in ccea ce priveste operatiunea propriu-zisa a
transferului, deosebit de important este respectarea cu strictete a protocolului intre personalul
desemnat al bancii si echipajul masinii.
Partitiile ce vizeaza zonele de procesare a banilor au un regim special in ceea ce
priveste dotarea tehnica. In primul rand pentru aceste zone a fost prevazuta o tastatura de
operare dedicata a sistemului de securitate, care impreuna cu o unitate biometrica de control
al accesului restrictioneaza fluxul de personal. Tezaurul din punct de vedere mecanic trebuie
sa corespunda SR-EN 1143 iar in ceea ce priveste protectia electronica se vor folosi
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.11/63 -
11 - Page 11

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
11
confidetial
8/27/2017/3
5 - 11 -74
- 11 -/35

detectoare de miscare, anti-masking detectoare de soc, contacte magnetice heavy doors cu


tripla polaritate butoane de panica; pedale de panica.
Pentru restul partitiilor dotarea din punct de vedere electronic este standard si poate
contine detectoare de miscare, detectoare de geam spart, detectoare de inundatie, contacte
magnetice standard.
Paza sediului este asigurata in intervalul 07.00 19.00 de catre un agent de la aceeasi
societate care asigura monitorizarea si interventia in caz de eveniment. Acesta stationeaza
intr-o zona situata vizavi de ghiseele de casa fara a avea la dispozitie un spatiu delimitat, zona
unde sunt prevazute o tastatura de operare a sistemului de alarma unde poate vizualiza starea
in timp real a fiecarei zone a acestuia si un buton de panica in caz de hold-up.
In intervalul 07.00 19.00 si 17.00 19.00 se efectueaza activitati de curatenie de catre
personal specializat, activitati supervizate de catre agentul de paza, care la ora 19.00
impreuna cu o persoana desemnata din cadrul bancii activeaza sistemul de securitate,
moment dupa care paza obiectivului se realizeaza exclusiv electronic.
Semnalizarea efractiei se realizeaza atat acustic, prin intermediul sirenelor amplasate
in interiorul si exteriorul cladirii, la unitatea centrala, cat si pe cai diferite de comunicatie la
distanta spre un dispecerat al firmei de paza, ce monitorizeaza obiectivul. Amplasarea
elementelor de detectie este prezentata in partea desenata a proiectului. Zonele sistemului
sunt prezentate in tabelul de adresare din cadrul proiectului.
Reteaua de detectie la efractie este realizata cu detectoare infrarosu, detectoare dubla
tehnologie, detectoare de geam spart, detectoare de soc; contacte magnetice, butone de
panica, pedale de panica, tastaturi, de urmatoarele tipuri: (EN 50131-3, grad de securitate 3,
clasa de mediu 2).
Reteaua de avertizare acustica este realizata cu sirene de semnalizare penru interior si
exterior conectate pe linii separat.
Reteaua de interconectare intre elementele sistemului este realizata dupa cum urmeaza:
-cu cablu de semnalizare tip EL 6x0.22 mm pentru PIR, DGS si CM; adresabile;
-cu cablu de semnalizare tip EL 4x0.22 mm pentru BP, PP, GS; elemente pasive;
-cu cablu de cupru 3x1.5mmp pentru alimentarea cu energie electrica;
Sistemele vor ndeplini urmtoarele funcii:
vor fi permanent active (vor semnaliza orice tentativ de deschidere a uilor
protejate), indiferent de starea de activare/dezactivare a subsistemului;
n starea activat, vor asigura blocarea electromecanic a uii protejate;
activarea sistemului local i blocarea uii nu se va putea realiza dect dac ua
este nchis i ncuiat;
vor permite dezactivarea local, de la tastatura pentru activitati autorizate;
n cazul dezactivrii, vor asigura deblocarea electromecanic a uii protejate;
n cazul deschiderii neautorizate a uii protejate, vor semnaliza local, sonor i
vizual starea de alarm;
vor fi conectate cu centrala subsistemului antiefracie ctre care vor transmite
urmtoarele date:

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.12/63 -
12 - Page 12

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
12
confidetial
8/27/2017/3
5 - 12 -74
- 12 -/35

dezactivarea sistemului local de la tastatura cu identificare a celui care a


dezactivat sistemul;
starea de ncuiere a uii protejate;
starea de deschidere a uii protejate;
starea de alarm ca urmare a deschiderii neautorizate;
activarea sistemului local.
Pentru ndeplinirea acestor cerinte, sistemele locale au urmtoarea structur:
Contact de supraveghere a strii uii (nchis/deschis). Pentru uile duble,
s-a prevazut cate un contact pentru fiecare usa;
Contact de supraveghere a ncuierii uii.
Tastatura de comanda:
Casieria i SAS-ul de transfer valori vor fi dotate conform normelor referitoare la
zonele n care se manevreaz lichiditi cu contact magnetic la usa si detectoare de micare
dubl tehnologie PIR+MW ; Pentru protectia personalului din casierie s-a prevazut buton si
pedala de panica. Accesul in casierie se va realiza prin activarea, dezactivarea sistemului de la
tastatura din incaperea decont, si pe baza de card prevazut la sistemul de control acces.
pentru toate suprafeele vitrate de exterior s-au prevazut contacte de
monitorizare a nchiderii/deschiderii geamului si detectoare de geam spart.
punctele de cas au fost dotate conform normelor referitoare la zonele n care se
manevreaz lichiditi cu butoane si pedale de panica.
Stabilirea zonelor protejate va fi facuta de comun acord cu beneficiarul in functie de
configuratia locatiei si cerintele actuale ale acesteia. Semnalizarea efractiei se realizeaza atat
acustic, prin intermediul sirenelor amplasate in interiorul si exteriorul cladirii, la unitatea
centrala cat si pe linie telefonica. Alarmarea in cazul unui efractii se face in interiorul si
exteriorul cladirii prin sirene.
Centrala de semnalizare efractie va realiza pe langa functiile proprii ale sistemului si
urmatoarele functii:
- preluarea i semnalizarea situaiilor de folosire incorect a subsistemului de control acces;
- preluarea i retransmiterea la dispeceratul de securitate a evenimentelor de alarm
declanate de subsistemul antiincendiu i TVCI (alarm de incendiu, lips semnal video,
sabotare echipamente, vandalism etc.);
Semnalizarea efractiei se realizeaza atat acustic cat si optic, prin intermediul sirenelor
amplasate in interiorul si exteriorul cladirii, la unitatea centrala, cat si pe cai diferite de
comunicatie la distanta spre un dispecerat ce monitorizeaza obiectivul. i.
Amplasarea elementelor de detectie este prezentata in partea desenata a volumului.
Zonele de armare/dezarmare sunt prezentate in Tabelul de adresare din cadrul proiectului.

6.1.2. Structura subsistemului antiefractie (specificatie echipament)

Subsistemul antiefractie este realizat cu urmatoarele echipamente:


Aceste elemente de detectie si semnalizare au rolul de a detecta si semnaliza efractia in
perimetrul protejat. Se vor folosi 27 detectori infrarosu, 9 detectori infrarosu dubla tehnologie, 27
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.13/63 -
13 - Page 13

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
13
confidetial
8/27/2017/3
5 - 13 -74
- 13 -/35

detectoare acustice de geam spart, 7 detectoare de soc, digitale; 18 senzori magnetici, 11


butoane de panica, 3 pedale de panica; 5 detectori de inundatie, 4 tastaturi si 13 module de
extensie (multiplexoare).
Drept dispozitive de avertizare sonora vom folosi 1 sirena cu sroboscop de exterior si
3 sirene de interior cu flash optic
Centrala de alarma tip INTEGRA 128, cu 16 zone pe placa de baza extensibila la 128 zone,
producator SATEL Polonia. Centrala este astfel proiectata incat sa permita sistemului de
alarma efrcatie sa fie in conformitate cu cerintele gradelor de securitate 1 si 2 din EN
50131-1 si EN 50131-6
Tastatura LCD : tastatura LCD cu 32 de caractere; LCD INT-KSG-BSB; SATEL Polonia,
Module extensie CA-64 E, producator SATEL Polonia,
Sursa realimentare magistrala 12Vcc tip SC-25 - producator ROEL ROMANIA
Sirena de exterior autonoma cu flash, autoprotejata, tip DECIBELL E - producator Pyronix - Anglia
corespunzand EN 50131;.
Sirena de interior tip SPW-250 R - producator SATEL Polonia corespunzand EN 50131;.
Detectori infrarosu: detector PIR anti-masking tip TOWER 10 AM, producator VISONIC Israel
corespunzand EN 50131;.
Detectori infrarosu dubla tehnologie : detector PIR + MW, anti-masking tip TOWER 12 AM, producator
VISONIC Israel, corespunzand EN 50131;.
Detectoare de geam spart: GLASS-TECH AM, producator VISONIC Israel, corespunzand EN
50131;.
Detector de soc digital: SHOCK SENSORS, SS-102, producator DSC Canada.,
Buton de panica: PANIC BUTON, producator TYCO ELECTRONICS Germania
corespunzand EN 50131;.
Pedala de panica: AWZ 710, producator PULSAR Polonia; corespunzand EN 50131;.
Contact magnetic adresabil: S-4, producator SATEL Polonia
Contact magnetic heavy doors adresabil: ISC-PRS-S3, producator BOSCH Germania,
corespunzand EN 50131;.
Detector de inundatie tip FD-1, producator SATEL Polonia

Specificatie echipament antiefractie


Nr. Denumire
Tip Cantit. Producator
Crt. produs
SATEL
INTEGRA
1. Centrala de alarma 1 POLONIA
128
Sursa in comutatie APS Satel Polonia
2. 3
1012
INT-KSG- SATEL
3. Tastatura LCD 4
BSB POLONIA
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.14/63 -
14 - Page 14

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
14
confidetial
8/27/2017/3
5 - 14 -74
- 14 -/35

Comunicator GSM SATEL


4. GSM/GPRS 1
LT-2 POLONIA
Modul extensie 8 SATEL
5. CA-64-E 13
zone I/O POLONIA
Detector de
TOWER- VISONIC
6. miscare in 27
10AM ISRAEL
infrarosu PIR
Detector de miscare
TOWER- VISONIC
7. in infrarosu-dual 9
12AM ISRAEL
PIR/MW
Detector geam GLASS VISONIC
8. 27
spart TECH-AM ISRAEL
DSC DSC
9. Detector de soc 7
SS-102 CANADA
BOSCH
10. Contact magnetic ISC-PRS-S3 8
GERMANIA
Contact mag. pt.usi SATEL
10 S-4 10
culisante POLONIA
TYCO
PANIC
11 Buton de panica 10 INTERNATIONA
BUTTON
L
PULSAR
12 Pedala de panica AWZ 710 3
POLONIA
SATEL
13. Siren de interior SPW-250 R 3
POLONIA
PYRONIX
14. Sirena de exterior DECIBELL E 1
ANGLIA
Acumulatori DSC
15. SL 7 4
12V/26Ah Canada
SA 62 BL
16. Cablu 6 fire 1500m Bentel Italia
6x0,22
17. Cablu 8 fire UTP 4x2x0,5 500m Alcatel
18. Tub flexibil D=20mm 300m SC Instal

Specificatii de materiale
Reteaua de interconectare intre elementele sistemului reprezinta infrastructura de cabluri
de diferite tipuri ce asigura legaturile electrice intre toate elementele instalatiei, astfel:
- interconectarea modulelor de extensie cat si a centralei cu modulele de extensie se
realizeaza folosind cablu UTP torsadat de categorie 5 enhanced (5e) UTP 4x2x0,5.
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.15/63 -
15 - Page 15

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
15
confidetial
8/27/2017/3
5 - 15 -74
- 15 -/35

- interconectarea detectorilor si a tastaturilor la modulele de extensie si centrala s-a


realizat intr-o structura cu topologie stea folosind cablu de alarma tip SA 62 BL 6x0,22
- traseele de cablu sunt protejate prin tub flexibil PVC tip Copex 20mm (pentru traseele
situate deasupra plafonului fals).

6.1.3 Descrierea zonelor protejate, antiefractie


Partitia Denumire Zona Denumire zona Element Localizar Tip zona
partitie detectie e
1 Self 1.1 Sala operatiuni PIRW2 hol instant
banking Self banking intrare
1 Self 2.1 Sala operatiuni DGS9 hol instant
banking Self banking intrare
1 Self 3.1 Sala operatiuni DGS10 hol instant
banking Self banking intrare
1 Self 4.1 Sala operatiuni CM1 hol temporizat
banking Self banking intrare
ATM 5.1 ATM CM4 ATM temporizat
2
2 ATM 6.1 ATM GS5 ATM 24 ore

2 ATM 7.1 ATM PIRW1 ATM instant

2 8.1 ATM GS6 ATM 24 ore


ATM
2 Birou IT 9.1 Birou IT PIR8 Birou IT instant

2 Birou IT 10.1 Birou IT CM3 Birou IT temporizat


2 SERVER 11.1 SERVER CM5 SERVER temporizat
2 SERVER 12.1 SERVER DI1 SERVER instant
2 SERVER 13.1 SERVER GS1 SERVER 24 ore
2 SERVER 14.1 SERVER PIR 1 SERVER instant
2 SERVER 15.1 SERVER BP1 SERVER panica
3 Casierie 16.1 Casa 1 PIRW5 Casa 1 instant
3 Casierie 17.1 Casa 1 PP1 Casa 1 panica
3 Casierie 17.2 Casa 1 BP6 Casa 1 panica
3 Casierie 18.1 Casa 2 PIRW4 Casa 2 instant
3 Casierie 19.1 Casa 2 PP2 Casa 2 panica
3 Casierie 19.2 Casa 2 BP5 Casa 2 panica
3 Preluare 20.1 Preluare numerar PIRW6 Preluare instant
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.16/63 -
16 - Page 16

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
16
confidetial
8/27/2017/3
5 - 16 -74
- 16 -/35

numerar numerar
3 Preluare 21.1 Preluare numerar BP Preluare panica
numerar numerar
3 Preluare 22.1 Preluare numerar CM13 Preluare temporizat
numerar numerar
3 Garaj 23.1 Garaj PIRW3 Garaj instant
preluare valori
3 Garaj 24.1 Garaj CM14 Garaj temporizat
preluare valori
3 Garaj 25.1 Garaj CM15 Garaj temporizat
preluare valori
4 Hol 26.1 Hol casierie CM10 Hol temporizat
casierie casierie
4 Hol 27.1 Hol casierie PIRW7 Hol instant
casierie casierie
4 Sala 28.1 Sala numarare PIRW9 Sala instant
numarare numarare
4 Sala 29.1 Sala numarare CM11 Sala temporizat
numarare numarare
4 Sala 30.1 Sala numarare PP3 Sala panica
numarare numarare
4 Sala 31.1 Sala numarare BP8 Sala panica
numarare numarare
4 Tezaur 32.1 Tezaur CM12 Tezaur temporizat
4 Tezaur 33.1 Tezaur BP7 Tezaur panica
4 Tezaur 34.1 Tezaur GS3 Tezaur 24 ore
4 Tezaur 35.1 Tezaur GS4 Tezaur 24 ore
4 Tezaur 36.1 Tezaur PIRW8 Tezaur instant
5 Restul 37.1 Hol clienti CM2 Hol clienti temporizat
spatiilor parter
5 Restul 38.1 Hol clienti PIR7 Hol clienti instant
spatiilor parter
5 Restul 39.1 Hol clienti PIR5 Hol clienti instant
spatiilor parter
5 Restul 40.1 Hol clienti PIR6 Hol clienti instant
spatiilor parter
5 Restul 41.1 Hol clienti BP3 Hol clienti panica
spatiilor parter
5 Restul 42.1 Hol clienti DGS8 Hol clienti instant
spatiilor parter
5 Restul 43.1 Hol clienti DGS11 Hol clienti instant
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.17/63 -
17 - Page 17

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
17
confidetial
8/27/2017/3
5 - 17 -74
- 17 -/35

spatiilor parter

5 Restul 44.1 Hol clienti PIR9 Hol clienti instant


spatiilor parter
5 Restul 45.1 Sala intalniri CM6 Sala temporizat
spatiilor parter intalniri
5 Restul 45.2 Sala intalniri PIR2 Sala instant
spatiilor parter intalniri
5 Restul 46.1 Sala intalniri DGS1 Sala instant
spatiilor parter intalniri
5 Restul 47.1 Sala intalniri DGS2 Sala instant
spatiilor parter intalniri
5 Restul 48.1 Casier sef CM7 Casier temporizat
spatiilor parter sef
5 Restul 48.2 Casier sef PIR3 Casier instant
spatiilor parter sef
5 Restul 49.1 Casier sef BP2 Casier panica
spatiilor parter sef
5 Restul 50.1 Casier sef DGS3 Casier instant
spatiilor parter sef
5 Restul 51.1 Casier sef GS2 Casier panica
spatiilor parter sef
5 Restul 52.1 Oficiu CM8 Oficiu temporizat
spatiilor parter
5 Restul 52.2 Oficiu PIR4 Oficiu instant
spatiilor parter
5 Restul 53.1 Oficiu DGS4 Oficiu instant
spatiilor parter
5 Restul 54.1 Oficiu DI2 Oficiu instant
spatiilor parter
5 Restul 55.1 WC parter CM9 WC temporizat
spatiilor parter parter
5 Restul 56.1 WC parter DGS7 WC instant
spatiilor parter parter
5 Restul 57.1 WC parter DGS6 WC instant
spatiilor parter parter
5 Restul 58.1 Scara parter DGS5 Scara instant
spatiilor parter parter
6 Conducere 59.1 Dir. general DGS16 Dir. instant
general
6 Conducere 60.1 Dir. general BP11 Dir. panica
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.18/63 -
18 - Page 18

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
18
confidetial
8/27/2017/3
5 - 18 -74
- 18 -/35

general
6 Conducere 61.1 Dir. general DGS17 Dir. instant
general
6 Conducere 62.1 Dir. general PIR22 Dir. instant
general
6 Conducere 63.1 Dir. general GS7 Dir. 24 ore
general
6 Conducere 64.1 Dir. adjunct PIR20 Dir. instant
adjunct
6 Conducere 65.1 Dir. adjunct DGS14 Dir. instant
adjunct
6 Conducere 66.1 Dir. adjunct BP9 Dir. panica
adjunct
6 Conducere 67.1 Secretariat PIR21 Secretari instant
at
6 Conducere 68.1 Secretariat DGS15 Secretari instant
at
6 Conducere 69.1 Secretariat BP10 Secretari panica
at
7 Arhiva 70.1 Arhiva curenta CM17 Arhiva temporizat
curenta
7 Arhiva 70.2 Arhiva curenta PIR35 Arhiva instant
curenta
7 Arhiva 71.1 Arhiva curenta DI4 Arhiva instant
curenta
7 Arhiva 72.1 Arhiva CM18 Arhiva temporizat
7 Arhiva 72.2 Arhiva PIR36 Arhiva instant
7 Arhiva 73.1 Arhiva DI5 Arhiva instant

8 Restul 74.1 Contabilitate DGS18 Contabilita instant


spatiilor te
etaj
8 Restul 75.1 Contabilitate PIR23 Contabilita instant
spatiilor te
etaj
8 Restul 76.1 Contabilitate DGS19 Contabilita instant
spatiilor te
etaj
8 Restul 77.1 Birou 2 PIR24 Birou 2 instant
spatiilor
etaj
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.19/63 -
19 - Page 19

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
19
confidetial
8/27/2017/3
5 - 19 -74
- 19 -/35

8 Restul 78.1 Birou 2 DGS20 Birou 2 instant


spatiilor
etaj
8 Restul 79.1 Birou 3 DGS21 Birou 3 instant
spatiilor
etaj
8 Restul 80.1 Birou 3 PIR25 Birou 3 instant
spatiilor
etaj
8 Restul 81.1 Birou 4 DGS22 Birou 4 instant
spatiilor
etaj
8 Restul 82.1 Birou 4 PIR26 Birou 4 instant
spatiilor
etaj
8 Restul 83.1 Terasa circulabila PIR19 Terasa instant
spatiilor circulabil
etaj a
8 Restul 84.1 Terasa circulabila PIR27 Terasa instant
spatiilor circulabil
etaj a
8 Restul 85.1 Terasa circulabila PIR28 Terasa instant
spatiilor circulabil
etaj a
8 Restul 86.1 Terasa circulabila PIR34 Terasa instant
spatiilor circulabil
etaj a
8 Restul 87.1 Terasa circulabila PIR29 Terasa instant
spatiilor circulabil
etaj a
8 Restul 88.1 WC-etaj CM16 WC-etaj temporizat
spatiilor
etaj
8 Restul 89.1 WC-etaj DGS13 WC-etaj instant
spatiilor
etaj
8 Restul 90.1 WC-etaj DGS12 WC-etaj instant
spatiilor
etaj
8 Restul 91.1 Scara etaj DGS23 Scara instant
spatiilor etaj
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.20/63 -
20 - Page 20

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
20
confidetial
8/27/2017/3
5 - 20 -74
- 20 -/35

etaj
8 Restul 92.1 Birou 1 negociere PIR30 Birou 1 instant
spatiilor negocier
etaj e
8 Restul 93.1 Birou 1 negociere DGS24 Birou 1 instant
spatiilor negocier
etaj e
8 Restul 94.1 Birou 2 negociere PIR21 Birou 2 instant
spatiilor negocier
etaj e
8 Restul 95.1 Birou 2 negociere DGS25 Birou 2 instant
spatiilor negocier
etaj e
8 Restul 96.1 Creditare DGS26 Creditare instant
spatiilor contracte contracte
etaj
8 Restul 97.1 Creditare DGS27 Creditare instant
spatiilor contracte contracte
etaj
8 Restul 98.1 Creditare PIR32 Creditare instant
spatiilor contracte contracte
etaj
8 Restul 99.1 Oficiu PIR33 Oficiu instant
spatiilor
etaj
8 Restul 100.1 Oficiu DI3 Oficiu instant
spatiilor
etaj

Legenda:
PIR detector de miscare IR cu anti-masking
PIRW detector de miscare dubla tehnologie cu anti-masking
DGS detector de geam spart
CM contact magnetic
GS detector de soc
BP buton de panica
PP pedala de panica
DI - detector de inundatii

3.1.4 Amplasamentul componentelor.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.21/63 -
21 - Page 21

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
21
confidetial
8/27/2017/3
5 - 21 -74
- 21 -/35

Zona 1 este declarata ca zona instant, are in compunere un detector dual PIRW si
supravegheaza spatiul din Windfang intrare clienti;
Zona 2 este declarata ca zona instant, are in compunere un detector de geam spartl
DGS, si este localizat la fereastra 1 hol intrare;
Zona 3 este declarata ca zona instant, are in compunere un detector de geam spartl
DGS si este localizat la fereastra 2, hol intrare;
Zona 4 este declarata ca zona temporizata, are in compunere un contact magnetic CM si
este
localizat la hol intrare;
Zona 5 este declarata ca zona temporizata, are in compunere contact magnetic CM si
supravegheaza usa bancomatul (ATM) ;
Zona 6 este declarata ca zona 24 ore, are in compunere un detector de socuri GS,
supravegheaza bancomatul (ATM;
Zona 7 este declarata ca zona instant, are in componenta un detector dual PIRW si
supravegheaza camera bancomat
Zona 8 este declarata ca zona zona 24 ore, are in componenta un detector de socuri GS
si supravegheaza PC-ul self banking;
Zona 9 este declarata ca zona instant, are in compunere un detector dual PIR si
supravegheaza spatiul din biroul IT;
Zona 10 este declarata ca zona temporizata , are in compunere un contact magnetic CM
si supravegheaza usa biroul IT;
Zona 11 este declarata ca zona temporizata, are in componenta un contact magnetic CM
si supravegheaza usa biroul server;
Zona 12 este declarata ca zona instant, are in componenta un detector de inundatie DI si
supravegheaza biroul server;
Zona 13 este declarata ca zona zona 24 ore, are in componenta un de socuri GS
supravegheaza serverul;
Zona 14 este declarata ca zona instant, are in compunere un detector dual PIR si
supravegheaza spatiul din supravegheaza biroul server;
Zona 15 este declarata ca zona panica, are in compunere un buton de panioca BP si
supravegheaza serverul;
Zona 16 este declarata ca zona instant, are in compunere un detector de miscare PIR si
un contact magnetic la fereastra si supravegheaza incaperea nefumatori;
Zona 17 este declarata ca zona panica, are in compunere un buton de panioca BP si o
pedala de panica PP si supravegheaza casa 1;
Zona 18 este declarata ca zona instant, are in compunere un detector dual PIRW si
supravegheaza casa 2;
Zona 19 este declarata ca zona panica, are in compunere un buton de panioca PP si o
pedala de panica PP si supravegheaza casa 2;
Zona 20 este declarata ca zona instant, are in compunere un detector dual PIRW si
supravegheaza zona preluare numerar;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.22/63 -
22 - Page 22

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
22
confidetial
8/27/2017/3
5 - 22 -74
- 22 -/35

Zona 21 este declarata zona panica, are in compunere un buton de panioca BP si


supravegheaza zona preluare numerar
Zona 22 este declarata ca zona temporizata , are in compunere un contact magneti CM si
supravegheaza usa zona preluare numerar
Zona 23 este declarata ca zona instant, are in compunere un detector dual PIRW si
supravegheaza garaj preluare valori
Zona 24 este declarata ca zona temporizata , are in compunere un contact magneti CM si
supravegheaza usa de la garaj preluare valori
Zona 25 este declarata ca zona temporizata , are in compunere un contact magneti CM si
supravegheaza usa de la garaj preluare valori
Zona 26 este declarata ca zona temporizata , are in compunere un contact magneti CM si
supravegheaza usa hol casierie;
Zona 27 este declarata ca zona instant, are in compunere un detector dual PIRW si
supravegheaza hol casierie;
Zona 28 este declarata ca zona instant, are in compunere un detector dual PIRW si
supravegheaza sala numarare;
Zona 29 este declarata ca zona temporizata , are in compunere un contact magneti CM si
supravegheaza usa de la sala numarare;
Zona 30 este declarata zona panica, are in compunere o pedala de panica PP si
supravegheaza birou sala numarare;
Zona 31 este declarata zona panica, are in compunere un buton de panica BP si
supravegheaza birou sala numarare;
Zona 32 este declarata ca zona temporizata, are in compunere un contact magneti CM si
supravegheaza usa de la tezaur;
Zona 33 este declarata zona panica, are in compunere un buton de panica BP si
supravegheaza hold-up la tezaur;
Zona 34 este declarata ca zona zona 24 ore, are in componenta un de socuri GS si
supravegheaza la tezaurul;
Zona 35 este declarata ca zona zona 24 ore, are in componenta un de socuri GS si
supravegheaza la tezaurul;
Zona 36 este declarata ca zona instant, are in compunere un detector dual PIRW si
supravegheaza zona de la tezaurul;
Zona 37 este declarata ca zona temporizata , are in compunere un contact magneti CM si
supravegheaza hol clienti;
Zona 38 este declarata ca zona instant , are in compunere un detector PIR si
supravegheaza hol clienti;
Zona 39 este declarata ca zona instant , are in compunere un detector PIR si
supravegheaza hol clienti;
Zona 40 este declarata ca zona instant , are in compunere un detector PIR si
supravegheaza hol clienti;
Zona 41 este declarata zona panica, are in compunere un buton de panica BP si
supravegheaza hol clienti;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.23/63 -
23 - Page 23

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
23
confidetial
8/27/2017/3
5 - 23 -74
- 23 -/35

Zona 42 este declarata ca zona instant, are in compunere un detector de geam spart DGS si
supravegheaza fereastra hol clienti;
Zona 43 este declarata ca zona instant, are in compunere un detector de geam spart DGS si
supravegheaza fereastra hol clienti;
Zona 44 este declarata ca zona instant, are in compunere un detector PIR si supravegheaza
hol clienti;
Zona 45 este declarata ca zona temporizata, are in compunere un contact magnetic CM si
un PIR, care supravegheaza usa de intrarea sala intalniri;
Zona 46 este declarata ca zona instant, are in compunere un detector de geam spart DGS
care supravegheaza sala intalniri
Zona 47 este declarata ca zona temporizata, are in compunere un contact magnetic CM
care supravegheaza usa birou casier sef;
Zona 48 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza usa birou casier sef;
Zona 49 este declarata zona panica, are in compunere un buton de panica BP si
supravegheaza birou casier sef;
Zona 50 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra din birou casier sef;
Zona 51 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra din birou casier sef;
Zona 52 este declarata ca zona temporizata, are in compunere un contact magnetic CM si
un detector PIR, care supravegheaza usa intrarea in oficiu;
Zona 53 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra oficiu;
Zona 54 este declarata ca zona instant, are in compunere un detector de inundatii DI si
supravegheaza oficiu;
Zona 55 este declarata ca zona temporizata, are in compunere un contact magnetic CM
Zona 56 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra WC parter;
Zona 57 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra WC parter
Zona 58 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza scara parter;
Zona 59 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra birou dir. general;
Zona 60 este declarata zona panica, are in compunere un buton de panica BP si
si supravegheaza birou dir. General;
Zona 61 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra birou dir. general;
Zona 62 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza birou dir. general

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.24/63 -
24 - Page 24

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
24
confidetial
8/27/2017/3
5 - 24 -74
- 24 -/35

Zona 63 este declarata ca zona zona 24 ore, are in componenta un de socuri GS si


supravegheaza safe dir. General;
Zona 64 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza birou dir. adjunct;
Zona 65 este declarata ca zona instant, are in compunere un detector de geam spart DGS
supravegheaza fereastra birou dir. adjunct;
Zona 66 este declarata zona panica, are in compunere un buton de panica BP si
si supravegheaza birou dir. adjunct;
Zona 67 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza birou secreatariat;
Zona 68 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra birou secreatariat
Zona 69 declarata zona panica, are in compunere un buton de panica BP si
si supravegheaza birou secreatariat
Zona 70 este declarata ca zona temporizata, are in compunere un contact magnetic CM si
un detector PIR si supravegheaza usa birou arhiva curenta;
Zona 71 este declarata ca zona instant, are in compunere un detector de inundatie DI4 si
si supravegheaza birou arhiva curenta;
Zona 72 este declarata ca zona temporizata, are in compunere un contact magnetic CM si
un detector PIR si supravegheaza usa birou arhiva ;
Zona 73 este declarata ca zona instant, are in compunere un detector de inundatie DI si
si supravegheaza birou arhiva;
Zona 74 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra birou contabilitate;
Zona 75 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza birou contabilitate;
Zona 76 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra birou contabilitate
Zona 77 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza birou 2;
Zona 78 este declarata ca zona instant, are in compunere un detector de geam spart DGS
supravegheaza birou 2;
Zona 79 este declarata ca zona instant, are in compunere un detector de geam spart DGS
supravegheaza usa birou 3;
Zona 80 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza birou 3;
Zona 81 este declarata ca zona instant, are in compunere un detector de geam spart DGS
supravegheaza usa birou 4;;
Zona 82 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza birou 4;
Zona 83 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza terasa circulabila;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.25/63 -
25 - Page 25

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
25
confidetial
8/27/2017/3
5 - 25 -74
- 25 -/35

Zona 84 este declarata ca zona instant, are in compunere un detector PIR si


supravegheaza terasa circulabila;
Zona 85 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza terasa circulabila;
Zona 86 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza terasa circulabila;

Zona 87 este declarata ca zona instant, are in compunere un detector PIR si


supravegheaza terasa circulabila;
Zona 88 este declarata ca zona temporizata, are in compunere un contact magnetic CM si
supravegheaza usa WC etaj;
Zona 89 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra1 WC etaj;
Zona 90 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza fereastra 2 WC etaj;
Zona 91 este declarata ca zona instant, are in compunere un detector de geam spart DGS
si supravegheaza scara etaj;
Zona 92 este declarata ca zona temporizat, are in compunere un detector PIR
supravegheaza birou 1 negociere;
Zona 93 este declarata ca zona instant, are in compunere un detector de geam spart DGS
supravegheaza ferteastra birou 1 negociere;
Zona 94 este declarata ca zona temporizat, are in compunere un detector PIR
supravegheaza birou 2 negociere;
Zona 95 este declarata ca zona instant, are in compunere un detector de geam spart DGS
supravegheaza ferteastra birou 2 negociere;
Zona 96 este declarata ca zona instant, are in compunere un detector de geam spart DGS
supravegheaza ferteastra birou creditare contracte;
Zona 97 este declarata ca zona instant, are in compunere un detector de geam spart DGS
supravegheaza ferteastra birou creditare contracte;
Zona 98 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza birou creditare contracte;
Zona 99 este declarata ca zona instant, are in compunere un detector PIR si
supravegheaza oficiu;
Zona 100 este declarata ca zona instant, are in compunere un detector de inundatii DI si
supravegheaza oficiu;
Centrala de alarma s-a amplasat in camera SERVER, unde de altfel se afla si restul
echipamentelor de securitate, camera protejata de un contact magnetic montat pe usa si un
detector PIR , iar tastaturile de operare ale sistemului sunt dispuse dupa cum urmeaza:
- Tastatura T 1 este localizata in cadrul punctului de paza de unde pot fi armate si dezarmate
zonele din ATM (personal paza care raspunde de ATM), server si birou IT apartinand partitiei
2, iar personalul de paza poate vizualiza starea in timp real a tuturor zonelor sistemului.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.26/63 -
26 - Page 26

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
26
confidetial
8/27/2017/3
5 - 26 -74
- 26 -/35

- Tastatura T 2 este localizata la intrare in hol clienti de unde pot fi armate si dezarmate zonele
zona Self Banking apartinind partitiei 1 si restul spatiilor de la parter apartinind partitiei 5.
- Tastatura T 3 este localizata la intrare hol casierie si personalul desemnat al bancii poate
arma si dezarma zonele: casierie, garaj preluare valori apartinand partitiei 3 si tezaur, sala
numerar apartinind partitiei 4;
- Tastatura T 4 este localizata la etaj pe peretele din dreapta (hol mic grup sanitar) de unde
personalul desemnat al bancii poate arma si dezarma zonele: conducere - apartinind partitiei
6, arhiva - apartinind partitiei 7 si restul spatiilor de la etaj - apartinind partitiei 8.
Alimentarea cu energie electrica se va realiza din tabloul electric de securitate pe circuit
separat comun tuturor echipamentelor de securitate centrale aflate in camera SERVER.
Modulele de extensie sunt amplasate intr-o retea de tip stea, distribuita in toata cladirea.
Pozitia exacta a fiecarui modul a fost aleasa astfel incat:
- modulul sa fie in centrul de greutate al ariei de deservire,
- lungimile cablurilor de la detectori la modul sa fie cat mai mici
- modulul sa fie protejat impotriva sabotajului voit sau accidental
- accesul la modul sa fie facil in vederea efectuarii procedurilor de service si mentenanta.

6.1.5. Calculul energetic al sistemului antiefractie.


Autonomia sistemului de alarm din sursa de rezerva trebuie sa respecte SR-EN
50131-6 si HG 1010/2004 si anume functionarea normala a acestuia este de minim 24 ore, cu
30 min in starea de alarm

Tabel calcul energetic

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.27/63 -
27 - Page 27

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
27
confidetial
8/27/2017/3
5 - 27 -74
- 27 -/35

Consum / bucata Consum total


Tensiune

Nr. bucati
<mA> <mA>
Nr. crt.

alimentare
Echipament

baza rezerva veghe alarma veghe alarma

1. Centrala Integra 128 230V ac 12V dc 150 mA 340 mA 1 150 mA 340 mA

Modul extensie CA-


2. 12V dc 12V dc 70mA 210mA 13 910mA 2730 mA
64-E
Tastatura LCD
3. 12V dc 12V dc 165 mA 175 mA 4 660 mA 700 mA
INT-KSG-BSB
Detector de miscare
4. PIR 12V dc 12V dc 12 mA 14 mA 27 324 mA 378mA
TOWER-10AM
Detector de miscare
5. 12V dc 12V dc 30 mA 30 mA 9 270 mA 270mA
dual TOWER-12AM

Detector geam spart


6. 12V 12V 15mA 40mA 27 405mA 1080mA
GLASS TECH AM

Detector de soc
7. 12V 12V 3.5 16mA 7 24.5 mA 112 mA
SS-102

Buton de panica
8. 12V 12V 2.5 15 mA 10 25 150
PANIK BUTTON

Pedala de panica
9. 12V 12V 17mA 30mA 3 51mA 90mA
AWZ 710
Sirena interioara SPW-
10. 12V dc 12V dc 0.01mA 90 mA 3 0.03 270 mA
250R
11. Sirena exterioara 12V dc 12V dc 50mA 250mA 1 50mA 0
DECIBELL E

CONSUM TOTAL : 2869mA 6120mA

Consumul maxim de curent al sistemului in cazul in care alimentarea cu 230Vca lipseste

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.28/63 -
28 - Page 28

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
28
confidetial
8/27/2017/3
5 - 28 -74
- 28 -/35

iar sistemul este in stare de alarma, asa cum reiese din, este:

N = [n] + 1 unde
N numarul de acumulatoare necesar
[n] partea intreaga a numarului n calculat cu ajutorul formulei:
n = ( Iv x 23,5 + Imax x 0,5 ) / Cac x 0,86
In care :
N numar acumulatori
Iv curentul consumat in stare de veghe
Imax curentul consumat in stare de alarma
C capacitatea nominala a acumulatorilor de 12v utilizati
n = (2.869x23,5 + 6.120x0,5)/24x0,86 =(67.42 + 3.06) /20.64=6745. /20.64 = 3.26
N = 3 +1 = 4

Numarul de acumulatori tampon necesari sistemului

Pentru asigurarea unei autonomii de 24 ore din care 30 minute n stare de alarma
s-au prevazut 4 acumulatori de 12V/26Ah. Rezult c se va folosi 4 acumulatori de
12V/26Ah, 2 pusi n cutia centralei, iar cate unul pus n cutia multiplexoarelorl(2 buc) zone.
Cutia multiplexorului este prevazut cu surs de 12V/10A
Calculul pentru o autonomie de funcionare timp de 30 minute n stare de alarm a
sirenei exterioare:
Curent consumat: 1400mA
Qac = (1400mA x 0,5 h )=700 mA=0,7Ah
Sirena exterioara are un acumulator de 12V cu o capacitate de 2.3Ah.

6.1.6 Date tehnice de catalog


Centrala de detectie si semnalizare efractie INTEGRA 128 Satel Polonia
Specificatii tehnice:
Centrala antiefractie adresabila INTEGRA 128 este un sistem programabil care prezinta
urmatoarele caracteristici tehnice:
32 partitii independente;
16 zone complet programabile, extensibila la 128 zone ;
sursa de alimentare de 12V /10A;
accepta 14 module de extensie a zonelor;
praguri de alarma programabile pentru fiecare zona;
4 iesire de releu (3A fiecare) programabile;
12 iesiri programabile open-colector (0,05A fiecare) extensibile la 128;
accepta maxim 8 tastaturi;
accepta maxim 8 cititoare de cheie digitala sau proximitate;

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.29/63 -
29 - Page 29

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
29
confidetial
8/27/2017/3
5 - 29 -74
- 29 -/35

3 magistrale de comunicatie pe 4 fire;


vizualizarea directa a starii partitiilor de la tastatura;
192+8+1 coduri de utilizator de 4-6 cifre cu 16 nivele de ierarhie;
128 de cartele de proximitate si/sau chei digitale;
memoreaza 22527 evenimente cu posibilitatea filtrarii;
comunicator digital multiprotocol incorporat;
interfata RS 232 pentru programare PC;
16 numere de telefon, 32 mesaje vocale(selectarea calitatii inregistrarii)
tensiune de alimentare 230v c.a./ 50 Hz;
curent maxim consumat 337 mA; capacitate acumulator 12V/24Ah
temperatura operare -10 +55 OC;
dimensiuni 264mmX134mm;
greutate 341g.
Tastatura INT-KSG-BSB Satel Polonia
Specificatii tehnice:
afisaj cu cristale lichide, alfanumeric, 2 randuri a cate 16 caractere, retroiluminat ajustabil;
are incorporat un cititor de proximitate cu functii specifice, cu posibilitatea utilizarii stand-alone;
are incorporat microfon si difuzor pentru functiile vocale;
tastatura cu senzori;
2 zone pentru extensii
permite afisarea urmatoarelor informatii: jurnalul de evenimente, starea zonelor, starea
partitiilor, ora si data sistemului, defecte;
permite semnalizarea acustica a: alarmelor, defectelor, temporizarilor (de intrare si
iesire), intarzierii la autoarmare, confirmarea/infirmarea actiunilor utilizatorilor;
semnalizeaza pierderea comunicatiei cu unitatea centrala;
semnalizeaza intrarea sistemului in mod service;
protectie antisabotaj (antismulgere si la deschidere);
comunicatie cu centrala pe 4 fire;
posibilitatea conectarii a unei intrari si a unei iesiri programabile(open collector 100mA);
carcasa din ABS cu reducerea propagarii flacarii;
tensiune alimentare 12VDC;
temperatura operare -10 +55 OC;
current stand-by 165 mA; max. 175 mA(alarma);
dimensiuni: 143mmX156mmX22mm; greutate 320g.

Detector de miscare PIR antimasking TOWER 10AM - Visonic Israel


Specificatii tehnice:
numarator de impulsuri selectabil pentru eliminarea alarmelor false;
antimasking cu reglarea sensibilitatii;
grad 3 de securitate si clasa 2 de mediu;
compensare termica automata;
carcasa robusta cu mecanism de inchidere prin culisare;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.30/63 -
30 - Page 30

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
30
confidetial
8/27/2017/3
5 - 30 -74
- 30 -/35

inaltimea de montare de la 1,5m la 4m prin suporti de tavan sau perete ;


unghi de detectie in plan orizontal 90O
2 tipuri de lentile disponibile: volumetrica si coridor (35m, 5 grade);
imunitate la descarcare electrostatica pana la 50 kV;
imunitate la perturbatii in RF: nu genereaza alarme false intr-un camp electromagnetic
cu modulatie de 20V/m pana la 2GHz;
curent consumat la 12 Vcc in stand-by 12 mA , alarma 14mA;
iesire de alarma si sabotaj pe contact de releu NC 0,1A/28Vcc
timp initializare 60 s, perioada de alarmare 2s;
LED de test activat/dezactivat intern;
tip piroelement quad cu zgomot redus;
tensiunea de alimentare 8-16Vdc;
toleranta la variatii lente de temperaturi pna la 1,7 OC/min;
diferenta de temperatura pentru alarma certa 6 OC;
gama de temperaturi de functionare 20 + 55 OC.
dimensiuni: 160mmX77mmX47mm, greutate 40g.

Detector de miscare dubla tehnologie PIR/MW antimasking TOWER 12AM - Visonic Israel
Specificatii tehnice:
detector piro-electric dual
detectie in microunde prin efect Doppler.
numarator de impulsuri selectabil pentru eliminarea alarmelor false;
antimasking cu reglarea sensibilitatii;
grad 3 de securitate si clasa 2 de mediu;
compensare termica automata;
domeniul reglabil; 10, 17, 25 m
imunitate la animale pana la 18 kg
carcasa robusta cu mecanism de inchidere prin culisare;
inaltimea de montare de la 1,5m la 4m prin suporti de tavan sau perete ;
unghi de detectie in plan orizontal 90O
2 tipuri de lentile disponibile: volumetrica si coridor (35m, 5 grade);
imunitate la descarcare electrostatica pana la 50 kV;
imunitate la perturbatii in RF: nu genereaza alarme false intr-un camp electromagnetic
cu modulatie de 20V/m pana la 2GHz;
curent consumat la 12 Vcc in stand-by 30 mA , alarma 30mA;
iesire de alarma si sabotaj pe contact de releu NC 0,1A/28Vcc
timp initializare 60 s, perioada de alarmare 2s;
LED de test activat/dezactivat intern;
tip piroelement quad cu zgomot redus;
tensiunea de alimentare 8-16Vdc;
toleranta la variatii lente de temperaturi pna la 1,7 OC/min;
diferenta de temperatura pentru alarma certa 6 OC;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.31/63 -
31 - Page 31

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
31
confidetial
8/27/2017/3
5 - 31 -74
- 31 -/35

gama de temperaturi de functionare 20 + 55 OC.


dimensiuni: 160mmX77mmX47mm, greutate 50g.

Detector acustic de geam spart digital GLASS TECH-AM - Visonic Israel


Specificatii tehnice:
grad 3 de securitate si clasa 2 de mediu;
ajustarea independenta a sensibilitatii;
raza de detectie 10m pentru spargere si 3m pentru taierea sticlei;
montaj universal, perete sau tavan;
detecteaza toate tipurile de sticla;
suprafata minima vitrata 300mm x 300mm;
unghi de detectie 170 grade;
iesire de alarma si sabotaj pe contact de releu NC 50mA/24Vcc;
imunitate la perturbatii in RF: nu genereaza alarme false intr-un camp electromagnetic
cu modulatie de 10V/m intre 80 si 1000MHz;
imunitate la descarcare electrostatica pana la 50 kV;
tensiune de alimentare 9 16Vdc;
curent consumat la 12 Vcc in stand-by 15 mA , alarma 40mA;
gama de temperaturi de functionare 20 +50 OC;
dimensiuni: 62mmX67mmX26mm, greutate 70g.

Senzor de soc acustic SS-102; DSC CANADA


Specificatii tehnice:
grad 3 de securitate si clasa 2 de mediu;
detector de soc cu microprocesor ;
calibrarea se face automat prin nivelul de impact in modul de invatare;
posibilitatea de testare a calibrarii;
sensibilitate programabila (1-8 pulsuri);
LED bicolor pentru indicarea starii curente;
iesire de alarma si sabotaj pe contact de releu NC 150mA/24Vcc;
tensiune de alimentare 9-16V DC
consum mediu 16mA
timp alarma aprox. 2.0 sec.
contact antisabotaj
gama temperatura functionare -20...+50 OC;
dimensiuni: 93mmX25mmX24mm, greutate 35g.
Raza de acoperire specifica fiecarui material:beton-1,5m;caramida-2,5m;peretefals-
1,5m;otel-3m;PVC-2,25m;lemn-3,5m.

Contact magnetic S- 4 ; Satel Polonia


Specificatii tehnice
tip constructiv: releu REED acionare cu magnet permanent ;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.32/63 -
32 - Page 32

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
32
confidetial
8/27/2017/3
5 - 32 -74
- 32 -/35

montaj aparent, carcasa din plastic ;


raza de actiune 18-20mm ;
maxim de tensiune comutata pe contactul reed-ului, 160v ;
puncte de legatura cu surub ;
materialul din care este facut contactul - ruten
curent de lucru: 50 mA la 12 V ;
distana de acionare: max. 2,5 cm;
temperatura de functionare -20...+50 OC;
greutate 22g.

Contact magnetic heavy doors ISC-PRS-S3 - Bosch Germania


Specificatii tehnice
tip constructiv: releu reed cu tripla polaritate ;
grad de securitate 3, clasa mediu 2 ;
distanta de operare aprox. 34mm ;
capacitate contact max.6w ;
montaj aparent, pentru usi heavy duty ;
carcasa din aluminiu, cablu incapsulat si protejat cu tub flexibil de otel
magnet polarizat axial 12x55mm AlNiCo;
curent de lucru: 50 mA la 12 V ;
dimensiuni 144x50x16,5 si 66x40 35 ;
temperatura de functionare -40...+70 OC.

Buton de panica cu retinere PANIC BUTON; Tyco International


Specificatii tehnice
constructiv: carcasa ABS acoperita cu metal 1mm grosime, memorie mecanica,
resetare cu cheie, releu REED actionare cu magnet permanent;
contact electric:NC 50mA/24Vcc ;
grad 2 de securitate, clasa de mediu 2;
material contact rhodium;
rezistenta contact 0,5 ohm;
mod de actionare : prin apasare;
temperatura de functionare -40...+50 OC;
dimensiuni 66x50x26.

Pedala de panica din metal AWZ 710; Pulsar Polonia


Specificatii tehnice:
montare sub birou sau pe perete la 15-20cm de sol;
contact electric:NC 50mA/24Vcc cu microswitch silentios;
mod de actionare : prin apasare de jos in sus sau lateral.
protectie tamper: C/NC/NO
alarma iesire: C/NC/NO
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.33/63 -
33 - Page 33

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
33
confidetial
8/27/2017/3
5 - 33 -74
- 33 -/35

tensiune: 11-14V, dc
dimensiuni: 123x67x36

Interfata USB UT-2USB Roger


Specificatii tehnice
Interfata 485/USB;
Distanta maxima pentru cablu USB 5 m;
Distanta maxima pentru 485 1200m;
Tensiunea de alimentare 5Vdc direct de la portul USB;
Viteza de comunicatie max.115,2 kbit/s;
Temperatura de operare 0 - +55 OC;
Dimensiuni 68x45x23mm, greutatea 35g.

Modul expandor CA-64 E Satel Polonia


Specificatii tehnice:
permite conectarea a 8 zone full programabile;
selectare configuratie intrari/iesiri prin dipswitch;
microcontacte antisabotaj (antismulgere si capac frontal deschis);
comunicatia cu centrala prin intermediul magistralei (4 fire);
tensiunea de alimentare 12 Vcc; consum 70 mA;
temperatura de functionare -10...+55 OC
dimensiuini 57 x 80 mm, greutate 47g.

Sursa in comutatie APS 1012 Satel Polonia


Specificatii tehnice:
sursa in comutatie protejata la scurt si supracurent;
4 iesiri programabile pentru supervizare de la distanta;
Circuit pentru controlul incarcarii;
Indicatie acustica in caz de defect;
carcasa de metal prevazuta cu contact antisabotaj;
tensiune de alimentare 230Vca, curent absorbit 0,9A;
tensiunea nominala de iesire 13,8Vdc, curent nominal 10A;
timp de reincarcare la 80% din capacitate, 24 ore;
acumulator back-up 2x12V/17Ah;
indicatii prin LED-uri pentru lipsa retea si defect;
temperatura de functionare +5...+45 OC;
dimensiuni 403 x 323 x 100 mm, greutate 8,6kg (cu acumulator).

Sirena avertizare efractie de interior SPW-220 Satel Polonia


Specificatii tehnice:
tensiunea de alimentare 13,8Vcc ;
consum acustic 100mA, optic 180mA ;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.34/63 -
34 - Page 34

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
34
confidetial
8/27/2017/3
5 - 34 -74
- 34 -/35

putere acustica 104dB la 1 m ;


clasa de protectie IP31 ;
temperatura de functionare -10...+55 OC;
protectie dubla ls sabotaj;
dimensiuini 87 x 134 x 37 mm), greutate 310g;
carcasa din plastic de culoare alba.

Sirena avertizare efractie de exterior tip DECIBELL Pyronix - Anglia


Specificatii tehnice
sirena de exterior autoalimentata cu microprocesor ;
carcasa din policarbonat proiectata sa reziste intemperiilor ;
protectie suplimentara data de carcasa metalica de interior ;
3 intrari pentru comanda sitena si flash ;
sunet modulat cu tonalitati diferite ;
trigerare ambele polaritati ;
autoprotectie contra taierii firelor , sabotajului si distrugere flash ;
timp de alarmare programabil ;
testare acumulatori si decuplare stroboscop la acumulator descarcat ;
grad de securitate 3 ,clasa de mediu 4 ;
tensiunea de alimentare10 13,8Vcc ;
frecventa sunetului 1475Hz ;
nivel sonor la 3m ,106dB ;
durata maxima de alarmare 3 minute;
clasa protectie IP 34 ;
acumulator back-up 12V/7Ah ;
curent stand-by 50 mA, in alarma(sirena activa) 250mA ;
temperatura de functionare -25...+55 OC;
dimensiuini 180 x 270 x 90 (mm), greutate 2,5kg(fara acumulator).

Comunicator telefonic GSM LT-2 Satel Polonia


simulator de linie telefonica incorporata;
comutare automata in modul GSM in cazul defectarii liniei fixe;
prelucreaza atat apeluri de intrare cat si de iesire;
protectie la supratensiuni pe linia telefonica;
modul GSM/GPRS dual band;
port serial RS-232 pentru programare;
4 intrari de alarma;
suporta mesaje SMS;
tensiunea de alimantare 13,8 Vdc;
consum in stand-by 50mA, iar in transmisie 500mA;
gama de temperaturi de functionare +5 +40 OC;
dimensiuni: 96mmX70mm, greutate 220g.
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.35/63 -
35 - Page 35

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
35
confidetial
8/27/2017/3
5 - 35 -74
- 35 -/35

6.1.7.Jurnal de cablu, efractie .


Nr. COD CABLU DE LA PRIN PANA LA TIP CABLU
Crt.
1. E1 CSE BP1 SA6BL 6x0,22
2. E2 CSE - BP2 SA6BL 6x0,22
3. E3 CSE BP3 SA6BL 6x0,22
4. E4 CSE BP4 SA6BL 6x0,22
5. E5 CSE BP5 SA6BL 6x0,22
6. E6 BP5 - PP2 SA6BL 6x0,22
7. E7 CSE BP6 SA6BL 6x0,22
8. E8 BP6 PP1 SA6BL 6x0,22
9. E9 CSE - BP7 SA6BL 6x0,22
10. E10 CSE - BP8 SA6BL 6x0,22
11. E11 BP8 - PP3 SA6BL 6x0,22
12. E12 CSE BP9 SA6BL 6x0,22
13. E13 CSE BP10 SA6BL 6x0,22
14. E14 CSE - SEI1 SA6BL 6x0,22
15. E15 SEI1 SEI2 SEI3 SA6BL 6x0,22
16. E16 CSE SEE1 SA6BL 6x0,22
17. E17 CSE DI1 SA6BL 6x0,22
18. E18 Ext 1 DI1 SA6BL 6x0,22
19. E19 Ext 1 - DI1 SA6BL 6x0,22
20. E20 Ext 1 - DI1 SA6BL 6x0,22
21. E21 Ext 1 - DI1 SA6BL 6x0,22
22. E22 Ext 1 - GS1 SA6BL 6x0,22
23. E23 Ext 1 - GS2 SA6BL 6x0,22
24. E24 Ext 1 - GS3 SA6BL 6x0,22
25. E25 Ext 2 - GS4 SA6BL 6x0,22
26. E26 Ext 2 - GS5 SA6BL 6x0,22
27. E27 Ext 2 - GS6 SA6BL 6x0,22
28. E28 Ext 2 - GS7 SA6BL 6x0,22
29. E29 Ext 2 - GS8 SA6BL 6x0,22
30. E30 Ext 2 - PIR7 SA6BL 6x0,22
31. E31 Ext 2 - CM3 SA6BL 6x0,22
32. E32 Ext 3 - PIR8 SA6BL 6x0,22
33. E33 Ext 3 - CM4 SA6BL 6x0,22
34. E34 Ext 3 - PIRW1 SA6BL 6x0,22
35. E35 Ext 3 - CM2 SA6BL 6x0,22
36. E36 Ext 3 - PIRW2 SA6BL 6x0,22
37. E37 Ext 3 PIRW3 SA6BL 6x0,22
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.36/63 -
36 - Page 36

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
36
confidetial
8/27/2017/3
5 - 36 -74
- 36 -/35

38. E38 Ext 3 - DGS9 SA6BL 6x0,22


39. E39 Ext 4 - CM1 SA6BL 6x0,22
40. E40 Ext 4 - DGS10 SA6BL 6x0,22
41. E41 Ext 4 - CM14 SA6BL 6x0,22
42. E42 Ext 4 - CM15 SA6BL 6x0,22
43. E43 Ext 4 - PIRW4 SA6BL 6x0,22
44. E44 Ext 4 - PIRW5 SA6BL 6x0,22
45. E45 Ext 4 - PIRW6 SA6BL 6x0,22
46. E46 Ext 5 - CM13 SA6BL 6x0,22
47. E47 Ext 5 - PIRW7 SA6BL 6x0,22
48. E48 Ext 5 - PIRW8 SA6BL 6x0,22
49. E49 Ext 5 - CM12 SA6BL 6x0,22
50. E50 Ext 5 - PIRW9 SA6BL 6x0,22
51. E51 Ext 5 - CM11 SA6BL 6x0,22
52. E52 Ext 5 - PIR9 SA6BL 6x0,22
53. E53 Ext 6 - DGS11 SA6BL 6x0,22
54. E54 Ext 6 - CM10 SA6BL 6x0,22
55. E55 Ext 6 - CM5 SA6BL 6x0,22
56. E56 Ext 6 - PIR1 SA6BL 6x0,22
57. E57 Ext 6 - CM6 SA6BL 6x0,22
58. E58 Ext 6 - PIR2 SA6BL 6x0,22
59. E59 Ext 6 - DGS1 SA6BL 6x0,22
60. E60 Ext 7 - DGS2 SA6BL 6x0,22
61. E61 Ext 7 - PIR3 SA6BL 6x0,22
62. E62 Ext 7 - DGS3 SA6BL 6x0,22
63. E63 Ext 7 - PIR4 SA6BL 6x0,22
64. E64 Ext 7 - DGS4 SA6BL 6x0,22
65. E65 Ext 7 - DGS5 SA6BL 6x0,22
66. E66 Ext 7 - PIR6 SA6BL 6x0,22
67. E67 Ext 8 - CM7 SA6BL 6x0,22
68. E68 Ext 8 - CM8 SA6BL 6x0,22
69. E69 Ext 8 - PIR6 SA6BL 6x0,22
70. E70 Ext 8 - DGS8 SA6BL 6x0,22
71. E71 Ext 8 - DGS7 SA6BL 6x0,22
72. E72 Ext 8 - CM9 SA6BL 6x0,22
73. E73 Ext 8 - DGS8 SA6BL 6x0,22
74. E74 Ext 9 - DGS23 SA6BL 6x0,22
75. E75 Ext 9 - PIR29 SA6BL 6x0,22
76. E76 Ext 9 - PIR30 SA6BL 6x0,22
77. E77 Ext 9 - DGS24 SA6BL 6x0,22

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.37/63 -
37 - Page 37

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
37
confidetial
8/27/2017/3
5 - 37 -74
- 37 -/35

78. E78 Ext 9 - PIR31 SA6BL 6x0,22


79. E79 Ext 9 - DGS25 SA6BL 6x0,22
80. E80 Ext 9 - DGS26 SA6BL 6x0,22
81. E81 Ext 10 - DGS27 SA6BL 6x0,22
82. E82 Ext 10 - PIR32 SA6BL 6x0,22
83. E83 Ext 10 - PIR33 SA6BL 6x0,22
84. E84 Ext 10 - PIR34 SA6BL 6x0,22
85. E85 Ext 10 - CM16 SA6BL 6x0,22
86. E86 Ext 10 - PIR35 SA6BL 6x0,22
87. E87 Ext 10 - CM17 SA6BL 6x0,22
88. E88 Ext 11 - PIR36 SA6BL 6x0,22
89. E89 Ext 11 - DGS12 SA6BL 6x0,22
90. E90 Ext 11 - DGS13 SA6BL 6x0,22
91. E91 Ext 11 - CM16 SA6BL 6x0,22
92. E92 Ext 11 - PIR19 SA6BL 6x0,22
93. E93 Ext 11 - DGS14 SA6BL 6x0,22
94. E94 Ext 11 - PIR20 SA6BL 6x0,22
95. E95 Ext 12 - PIR21 SA6BL 6x0,22
96. E96 Ext 12 - DGS15 SA6BL 6x0,22
97. E97 Ext 12 - DGS16 SA6BL 6x0,22
98. E98 Ext 12 - DGS17 SA6BL 6x0,22
99. E99 Ext 12 - PIR22 SA6BL 6x0,22
100. E100 Ext 12 - DGS18 SA6BL 6x0,22
101. E101 Ext 12 - PIR23 SA6BL 6x0,22
102. E102 Ext 12 - DGS19 SA6BL 6x0,22
103. E103 Ext 13 - PIR24 SA6BL 6x0,22
104. E104 Ext 13 - DGS20 SA6BL 6x0,22
105. E105 Ext 13 - DGS21 SA6BL 6x0,22
106. E106 Ext 13 - PIR25 SA6BL 6x0,22
107. E107 Ext 13 - DGS22 SA6BL 6x0,22
108. E108 Ext 13 - PIR26 SA6BL 6x0,22
109. E109 Ext 13 - PIR 27 SA6BL 6x0,22
110. E110 Ext 13 - PIR28 SA6BL 6x0,22
111. E111 CSE Ext 1 2xUTP 4x2x0,5
112. E112 Ext 1 - Ext 2 2xUTP 4x2x0,5
113. E113 Ext 2 - Ext 3 2xUTP 4x2x0,5
114. E114 Ext 3 - Ext 4 2xUTP 4x2x0,5
115. E115 Ext 4 - Ext 5 2xUTP 4x2x0,5
116. E116 Ext 5 - Ext 6 2xUTP 4x2x0,5
117. E117 Ext 6 - Ext 7 2xUTP 4x2x0,5

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.38/63 -
38 - Page 38

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
38
confidetial
8/27/2017/3
5 - 38 -74
- 38 -/35

118. E118 Ext 7 - Ext 8 2xUTP 4x2x0,5


119. E119 Ext 8 - Ext 9 2xUTP 4x2x0,5
120. E120 Ext 9 - Ext 10 2xUTP 4x2x0,5
121. E121 Ext 10 - Ext 11 2xUTP 4x2x0,5
122. E122 Ext 11 - Ext 12 2xUTP 4x2x0,5
123. E123 Ext 12 - Ext 13 2xUTP 4x2x0,5
124. E124 CSE - TC 1 UTP 4x2x0,5
125. E125 CSE - TC 2 UTP 4x2x0,5
126. E126 CSE - TC 3 UTP 4x2x0,5
127. E127 Ext 1 - TC 4 UTP 4x2x0,5
128. TES - CSE CYY-F 3x1,5mm
129. TES - SAUX1 CYY-F 3x1,5mm
130. TES - SAUX2 CYY-F 3x1,5mm

Cabluri de legatura si interconectari


Cablurile de legatura sunt cabluri speciale pentru automatizari si semnalizari, ecranate,
torsadate si izolate in PVC special concepute pentru aplicatii antiefractie
EL 6x0.22 mmp sau 4x0.22mmp. Acestea vor fi montate prin pat cablu tip MCSE1 MCSE3
sau prin tub PVC-IPEY 20mm. Modul de pozare a circuitelor de interconectare prezentat
anterior este urmatorul:
- Protejat in tuburi PVC montate in plafonul aparent si fals, unde e cazul;
- Protejat in tuburi PVC montate aparent pe elementele constructiei ;
- Montate aparent pe patul de cabluri de curenti slabi
- Traseele circuitelor de detectie si alarmare de curenti slabi sunt realizate separat de circuitele
electrice de 0,4 kV, la o distanta minima de 30cm.

6.2. Subsistem control acces


6.2.1 Generalitati
La proiectarea subsistemului de control acces s-a tinut cont de destinatia cladirii, astfel
incat fluxurile de acces ale personalului in interiorul cladirii sa se desfasoare in mod controlat.
Prin intermediul acestui subsistem se poate monitoriza, controla si limita deplasarea
personalului in cladire.
Are urmatoarele caracteristici principale:
gestioneaza 1 usa, dublu sens , cu elementele de actionare mecanica;
elementele de identificare sunt cartele de proximitate;
orice deschidere a usii este memorata (utilizator,data,ora,minut);
controlerul comanda direct fiecare element de blocare fizica a accesului in mod
individual;
numar maxim de utilizatori 1000/controler;
memorie interna nevolatila;
posibilitati de extindere ulterioara.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.39/63 -
39 - Page 39

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
39
confidetial
8/27/2017/3
5 - 39 -74
- 39 -/35

Structural sistemul se compune din urmatoarele echipamente: controlere, cititoare de


cartele de proximitate, contacte magnetice, butoane de iesire, yala electromagnetica,
electomagneti 250 500 kgf, server control acces. Setarea sistemului de control acces se
poate face centralizat prin intermediul computerului PC (server control acces) conectat la
controlere, care va gestiona miscarea persoanelor pe usile restrictionate ;.

Specifiactie echipamente control acces.


Nr. Denumire produs TIP Cant. Producator OBS
Crt. .
1. Controler acces AC-215 IP 12 Rossalare
Cititor biometric AY-B1663 2 Rossalare
2. Cititor proximitate AY-CR12 10 Rossalare
3. Cartela de proximitate Rossalare
AT-R11 20
4. Electromagnet F ZM 12 YLI
Romania
5. Buton deschidere usa PB-038B 8
6. Buton iesire urgenta 12 YLI Romania
ABK-805
7. Amortizor usa ABK-800A 12 YLI Romania
8. Acumulator SL-12 12 ROEL
12V/12Ah, Romania

Specificatii de materiale
Reteaua de interconectare intre elementele subsistemului reprezinta infrastructura de
cabluri de diferite tipuri ce asigura legaturile electrice intre toate elementele instalatiei, astfel:
- Interconectarea intre centrala si modulele periferice precum si interconectarea intre
modulele periferice se realizeaza cu cablu UTP 4x2x0,5.
- Interconectarea dispozitivelor montate la fiecare usa se realizeaza printr-o doza
montata langa usa. Legatura intre modulul de control acces si doza se realizeaza cu 2 cabluri
JY(St)Y 4x2x0,8.
- Legatura de la doza la dispozitivele montate la usa se realizeaza cu cablu JY(St)Y
4x2x0,8 pentru cititor si cu cablu CSYY F 3x1,5 pentru restul dispozitivelor.
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.40/63 -
40 - Page 40

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
40
confidetial
8/27/2017/3
5 - 40 -74
- 40 -/35

- Alimentarea la reteaua de 230 Vca se realizeaza cu cablu CYY-F 3X1,5 din tabloul
electric de securitate amplasat in camera SERVER.
- Cablurile se pozeaza pe pat de cablu existent si in tub Copex 20mm(pentru traseele
situate deasupra plafonului fals)

6.2.3 Descrierea zonelor protejate (control acces


Nr.c Control Element Localizare Tip cititor Elem. Identif.
rt usa blocare
1. bisens elmag. Intrare server CR R870-A CR-R706-A
2. bisens elmag. Intrare principala sala Self CR R870-A CR-R706-A
3. bisens elmag. Intrare hol clienti CR R870-A CR-R706-A
4. bisens elmag. Intrare garaj valori CR R870-A CR-R706-A
5. bisens elmag. Iesire hol casierie CR R870-A CR-R706-A
6. unisens elmag. Intrare sala numerar F10 amprenta
7. unisens elmag. Intrare tezaur CR R870-A CR-R706-A
8. bisens elmag. Intrare hol casierie CR R870-A CR-R706-A
9. unisens elmag. Intrare self banking F10 amprenta
10. unisens elmag. Intrare casier sef CR R870-A CR-R706-A
11. unisens elmag. Intrare arhiva etaj CR R870-A CR-R706-A
12. unisens elmag. Credite-contracte CR R870-A CR-R706-A

6.2.4 Amplasamentul componentelor


Stabilirea zonelor protejate este realizata armonizand cerintele beneficiarului cu
normativele nationale si europene ce se impun in astfel de cazuri, astfel ca dupa o analiza
riguroasa s-a stabilit un numar de 12 puncte de control accces dupa cum urmeaza:
1. Server unde sunt amplasate toate echipamentele sistemului de securitate are prevazut un
cititor de proximitate ( exterior) , si butoane cerere iesire si urgenta, care impreuna actioneaza,
un bolt electromagnetic pentru deschiderea usii. Usa este prevazuta cu senzor magnetic, si
cilindru cu cheie si de asemenea este prevazuta cu un amortizor;
2. Intrare principala sala self; contine doua cititoare de cartele (interior, exterior) un bolt
electromagnetic cu temporizare, buton deschidere usa, senzor magnetic, cilindru cu cheie si
un amortizor;
3. Intrare hol clienti, contine doua cititoare de cartele (interior, exterior) un bolt
electromagnetic cu temporizare, buton deschidere usa, senzor magnetic, cilindru cu cheie si
un amortizor;
4. Intrare garaj valori contine doua cititoare de cartele (interior, exterior) un bolt
electromagnetic cu temporizare, buton deschidere usa, senzor magnetic si cilindru cu cheie si
un amortizor;
5. Iesire hol casierie, contine doua cititoare de cartele (interior, exterior) un bolt
electromagnetic cu temporizare, buton deschidere usa, senzor magnetic si cilindru cu cheie si
un amortizor;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.41/63 -
41 - Page 41

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
41
confidetial
8/27/2017/3
5 - 41 -74
- 41 -/35

6. Intrare sala numerar, contine un cititor de cartele (exterior) un bolt electromagnetic cu


temporizare, butoane deschidere usa si urgenta, senzor magnetic si cilindru cu cheie si un
amortizor;
7. Intrare tezaur, contine un cititor de proximitate ( exterior) si butoane cerere iesire si
urgenta, care impreuna actioneaza, un bolt electromagnetic pentru deschiderea usii. Usa este
prevazuta cu senzor magnetic, si cilindru cu cheie si de asemenea este prevazuta cu un amortizor;
8. Intrare hol casierie, contine doua cititoare de cartele (interior, exterior) un bolt
electromagnetic cu temporizare, buton deschidere usa, senzor magnetic si cilindru cu cheie si
un amortizor;
9. Intrare self banking, contine un cititor de cartele (exterior) un bolt electromagnetic cu
temporizare, butoane deschidere usa si urgenta, senzor magnetic si cilindru cu cheie si un amortizor;
10. Intrare casier sef, contine un cititor de cartele (exterior) un bolt electromagnetic cu
temporizare, buton deschidere usa, senzor magnetic si cilindru cu cheie si un amortizor;
11. Intrare arhiva etaj, contine un cititor de cartele (exterior) un bolt electromagnetic cu
temporizare, buton deschidere usa, senzor magnetic si cilindru cu cheie si un amortizor;
12. Intrare arhiva etaj, contine un cititor de cartele (exterior) un bolt electromagnetic cu
temporizare, buton deschidere usa, senzor magnetic si cilindru cu cheie si un amortizor;

6. 2.5 Calculul energetic al sistemului control acces pe o usa

Nr. Echipament Consum / bucata Nr. Consum total


crt (mA) bucati (mA)
1 Electromagnet
420 1 420
de forta 500 Kgf

Timp minim de functionare a sistemului pe acumulator este de 24h si este data de relatia.
Iac=Itotalx24h
420mAx24h=10080mA

Rezulta ca pe fiecare unitate de control acces se va monta cate un acumulator de


12V/12Ah in total este nevoie de 12 acumulatori
Unitatea de control este prevazuta cu sursa de alimentare de

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.42/63 -
42 - Page 42

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
42
confidetial
8/27/2017/3
5 - 42 -74
- 42 -/35

6.2.6 Date tehnice de catalog


Structural sistemul se compune dintr-un numar de controlere ce contin si cititoarele de
proximitate, elementele de supervizarea usilor si cele de actionare mecanica, un controler de
retea ce asigura buffer-ul (250000 evenimente) si sincronizarea temporala (real time clock)
pentru maxim 32 de controlere si un PC cu softul specific de management.
Modul control acces AC-215IP
Specificatii tehnice:
Centrala control acces 1 usa bidirectionala sau 2 usi unidirectionale
2 cititoare, 4 intrari/4 iesiri, extensibila la maxim 256 usi
30000 utilizatori, memorie 20000 evenimente
port RS232, RS485 si Ethernet - conectare TCP/IP
convertor MD14 conectare pe RS485
2 relee comanda usa
transformator si sursa cu posibilitate incarcare acumulator
sirena interna, cutie inclusa
software management pana la 64 centrale inclus

Cititor de proximitate tip; AY-CR12


Specificatii tehnice
alimentare 12 VDC
consum Standby 25 mA, read 60 mA
lungimea cablului pana la controler max 150 m
Wiegand 26-bit
indicator LED
modulatia RF: ASK, 125 kHz
distanta de citire 80 mm
temperatura de operare -31C la 63C
Dimensiunea (H x W x D) 130 x 41,7 x 19 mm

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.43/63 -
43 - Page 43

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
43
confidetial
8/27/2017/3
5 - 43 -74
- 43 -/35

Cititor biometric AYC B7661

convertibil poate functiona ca cititor sau controller standalone (fara PC)


Suporta tehnologiile 1:1 / 1:n
Accepta pana la107 utilizatori
Tamper cu sensor optic pentru carcasa si perete
Utilizare in interior
Suporta posibilitate de blocaj pentru securitate marita
Format de iesire multiplu, Wiegand 26-bit si multe alte formate
Compatibil cu programatorul de carduri Rosslare CP-R26
Citeste carduri Mifare ISO14443 Type A standard
temperatura de operare -25 C la 60 C
dimensiuni 102 mm x 54 mm x 32 mm
greutate 156 g

Cartela de proximitate AT-R11


Specificatii tehnice:
- are dimensiunea unei carti de credit
- foarte subtire si flexibila
- fanta verticala pentru agatare
- carcasa durabila din PVC (alba)
- pasiva (nu necesita baterie)
- permite personalizarea prin tiparire de inalta calitate, direct pe cartela

Buton de iesire YLI ABK-800A YLI Romania


Specificatii tehnice:
- buton iesire incastrabil
- carcasa din duraluminiu
- curent maxim suportat 3A/36Vcc
- contacte NC/NO.
- dimensiuni: 86x50x20
- greutate: 0.16 kg

Contact magnetic DGP2-ZC1 PARADOX CANADA


Specificatii tehnice:
- contact magnetic adresabil
- 1 zona adresabila pt. sisteme DIGIPLEX
- contacte NC/NO.
- dimensiuni: 7.4x2x3.05

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.44/63 -
44 - Page 44

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
44
confidetial
8/27/2017/3
5 - 44 -74
- 44 -/35

Yalla electromagnetica YM-500BZ


Specificatii tehnice:
elecromagnet cu forta de retinere 500kgf
Consum: 420mA la 12Vcc - 210mA la 24Vcc
Marime: 282x67x39 mm
Marime contraplaca: 186x60x13 mm
Alte caracteristici: led bicolor de monitorizare; monitorizare stare usa - buzzer cu temporizare 5, 10,
20, 30 sec.; deschis la intreruperea alimentarii (fail safe); carcasa solida din metal inoxidabil

Amortizor hidraulic YLI YA 98; YLI Romania


Specificatii tehnice:
Constructie cu brat articulat
Reglaje pentru stabilirea vitezeidr inchidere
Montaj pe poartea dreapta sau stanga
Amortizor de usa pe baza de ulei hidraulic,
Fara posibilitatea de blocare la un anumit unghi
Utilizare pentu usi cu latimea de maxim1.5m si greutate maxima de 85kg.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.45/63 -
45 - Page 45

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
45
confidetial
8/27/2017/3
5 - 45 -74
- 45 -/35

-
Cablare
Reteaua de interconectare intre elementele sistemului este realizata dupa cum urmeaza:
Pentru sistemul de supraveghere control acces s-au folosit cabluri tip UTP 4x2x0.5mm pentru
magistrala si CSYY-F 3x2.5mm pentru alimentarea cu 230V, 50Hz a unitatilor slave.
Cablurile vor fi protejate pe traseu prin canal cablu MCSE1 MCSE3 sau prin tub PVC-IPEY 20mm.

6.2.7 Jurnal de cabluri, control acces.

Nr. COD CABLU DE LA PRIN PANA LA TIP CABLU


Crt.
1 CA 1 CCA1 - CCA 2 JY(St)Y 4x2x0,8
2 CA 2 CCA2 - CCA3 JY(St)Y 4x2x0,8
3 CA 3 CCA3 - CCA4 JY(St)Y 4x2x0,8
4 CA 4 CCA4 - CCA5 JY(St)Y 4x2x0,8
5 CA 5 CCA5 - CCA6 JY(St)Y 4x2x0,8
6 CA 6 CCA6 - CCA7 JY(St)Y 4x2x0,8
7 CA 7 CCA7 - CCA8 JY(St)Y 4x2x0,8
8 CA 8 CCA8 - CCA9 JY(St)Y 4x2x0,8
9 CA 9 CCA9 - CCA10 JY(St)Y 4x2x0,8
10 CA 10 CCA10 - CCA11 JY(St)Y 4x2x0,8
11 CA 11 CCA11 - CCA12 JY(St)Y 4x2x0,8
12 CA 12 CCA1 - DC1 2xJY(St)Y 4x2x0,8
13 CA 13 DC1 - CP JY(St)Y 4x2x0,8
14 CA 14 DC1 - B1 JY(St)Y 2x2x0,8
15 CA 15 DC1 - CM JY(St)Y 2x2x0,8
16 CA 16 DC1 - EM JY(St)Y 2x2x0,8
17 CA 17 DC1 - B1.1 JY(St)Y 2x2x0,8
18 CA 18 CCA2 - DC2 2xJY(St)Y 4x2x0,8
19 CA 19 DC2 - CP1 JY(St)Y 4x2x0,8
20 CA 20 DC2 - CP2 JY(St)Y 2x2x0,8
21 CA 21 DC2 - B2 JY(St)Y 2x2x0,8
22 CA 22 DC2 - CM JY(St)Y 2x2x0,8
23 CA 23 DC2 - EM JY(St)Y 2x2x0,8
24 CA 24 CCA3 - DC3 2xJY(St)Y 4x2x0,8
25 CA 25 DC3 - CP1 JY(St)Y 4x2x0,8
26 CA 26 DC3 - CP2 JY(St)Y 4x2x0,8
27 CA 27 DC3 - B3 JY(St)Y 2x2x0,8
28 CA 28 DC2 - CM JY(St)Y 2x2x0,8
29 CA 29 DC3 - EM JY(St)Y 2x2x0,8
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.46/63 -
46 - Page 46

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
46
confidetial
8/27/2017/3
5 - 46 -74
- 46 -/35

30 CA 30 CCA4 - DC4 2xJY(St)Y 4x2x0,8


31 CA 31 DC4 - CP1 JY(St)Y 4x2x0,8
32 CA 32 DC4 - CP2 JY(St)Y 4x2x0,8
33 CA 33 DC4 - B4 JY(St)Y 2x2x0,8
34 CA 34 DC4 - CM JY(St)Y 2x2x0,8
35 CA 35 DC4 - EM JY(St)Y 2x2x0,8
36 CA 36 CCA5 - DC5 2xJY(St)Y 4x2x0,8
37 CA 37 DC5 - CP1 JY(St)Y 4x2x0,8
38 CA 38 DC5 - CP2 JY(St)Y 4x2x0,8
39 CA 39 DC5 - B5 JY(St)Y 2x2x0,8
40 CA 40 DC5 - CM JY(St)Y 2x2x0,8
41 CA 41 DC5 - EM JY(St)Y 2x2x0,8
42 CA 42 CCA6 - DC6 2xJY(St)Y 4x2x0,8
43 CA 43 DC6 - CP JY(St)Y 4x2x0,8
44 CA 44 DC6 - B6 JY(St)Y 4x2x0,8
45 CA 45 DC6 - CM JY(St)Y 2x2x0,8
46 CA 46 DC6 - EM JY(St)Y 2x2x0,8
47 CA 47 DC6 - B6.1 JY(St)Y 2x2x0,8
48 CA 48 CCA7 - DC7 2xJY(St)Y 4x2x0,8
49 CA 49 DC7 - CP JY(St)Y 4x2x0,8
50 CA 50 DC7 - B7 JY(St)Y 2x2x0,8
51 CA 51 DC7 - CM JY(St)Y 2x2x0,8
52 CA 52 DC7 - EM JY(St)Y 2x2x0,8
53 CA 53 DC7 - B7.1 JY(St)Y 2x2x0,8
54 CA 54 CCA8 - DC8 2xJY(St)Y 4x2x0,8
55 CA 55 DC8 - CP1 JY(St)Y 4x2x0,8
56 CA 56 DC8 - CP2 JY(St)Y 2x2x0,8
57 CA 57 DC8 - B8 JY(St)Y 2x2x0,8
58 CA 58 DC8 - CM JY(St)Y 2x2x0,8
59 CA 59 DC8 - EM 2xJY(St)Y 4x2x0,8
60 CA 60 CCA9 - DC9 JY(St)Y 4x2x0,8
61 CA 61 DC9 - CP JY(St)Y 4x2x0,8
62 CA 62 DC9 - B9 JY(St)Y 2x2x0,8
63 CA 63 DC9 - CM JY(St)Y 2x2x0,8
64 CA 64 DC9 - EM JY(St)Y 2x2x0,8
65 CA 65 DC9 - B9.1 JY(St)Y 2x2x0,8
66 CA 66 CCA10 - DC10 2xJY(St)Y 4x2x0,8
67 CA 67 DC10 - CP JY(St)Y 4x2x0,8
68 CA 68 DC10 - B10 JY(St)Y 2x2x0,8
69 CA 69 DC10 - CM JY(St)Y 2x2x0,8

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.47/63 -
47 - Page 47

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
47
confidetial
8/27/2017/3
5 - 47 -74
- 47 -/35

70 CA 70 DC10 - EM JY(St)Y 2x2x0,8


71 CA 71 DC10 - B10.1 JY(St)Y 2x2x0,8
72 CA 72 CCA11 - DC11 2xJY(St)Y 4x2x0,8
73 CA 73 DC11 - CP JY(St)Y 4x2x0,8
74 CA 74 DC11 - B11 JY(St)Y 2x2x0,8
75 CA 75 DC11 - CM JY(St)Y 2x2x0,8
76 CA 76 DC11 - EM JY(St)Y 2x2x0,8
77 CA 77 DC11 - B11.1 JY(St)Y 2x2x0,8
78 CA 78 CCA12 - DC12 2xJY(St)Y 4x2x0,8
79 CA 79 DC12 - CP JY(St)Y 4x2x0,8
80 CA 80 DC12 - B12 JY(St)Y 2x2x0,8
81 CA 81 DC12 - CM JY(St)Y 2x2x0,8
82 CA 82 DC12 - EM JY(St)Y 2x2x0,8
83 CA 83 DC12 - B12.1 JY(St)Y 2x2x0,8
84 CA 84 TES - CCA1 CYY-F 3x1,5mm
85 CA 85 TES CCA CCA5 CYY-F 3x1,5mm
2,3,4
86 CA 86 TES CCA 5-10 CCA11 CYY-F 3x1,5mm

6.3 Subsistem TVCI


6.3.1 Generalitati
Proiectul cuprinde o instalatie de televiziune cu circuit inchis ce are in componenta
sistemul DVR (DIGITAL VIDEO RECORDER) care este un sistem de inregistrare si redare
digitala a imaginilor si o serie de camere video color amplasate n locurile care necesita
supraveghere
S-au prevazut camere video color, cu obiectiv autoiris si varifocal, de inalta rezolutie
folosite atat la interior cat si la exterior pentru protectia perimetrala a cladirii precum si a cailor
de acces si incaperilor din interiorul obiectivului, 1 inregistrator digital stand alone cu 32 canale
si 3 monitoare color LCD pentru vizualizarea in timp real a inregistrarilor situate la punctul de
paza, server si dir. adjunct.
Sistemul cuprinde 31 camere video dintre care 3 camere video de exterior si 28 cam.
video de interior.
Informatia video provenita de la camerele video este procesata pe unitatea digitala si
stocata pe suport hard-disk intern .
Pentru fiecare camera se poate seta rata de inregistrare in functie de importanta si
evenimentele aparute: detectia de miscare, eveniment datorat utilizatorului, semnal primit de
la senzorii conectati la sistem, modul alarma, pierdere de semnal (imagini anterioare pierderii
semnalului).

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.48/63 -
48 - Page 48

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
48
confidetial
8/27/2017/3
5 - 48 -74
- 48 -/35

Redarea imaginilor inregistrate (playback) se poate face atat local (de pe statia pe care
acestea sunt stocate) cat si la distanta (remote) de pe o alta statie aflata in retea.
De asemenea este posibila vizualizarea in timp real a camerelor aflate pe alte statii din
retea.

6.3.2 Structura subsistemului TVCI (specificatie echipament)


Sistemul de supraveghere video este realizat cu urmatoarele echipamente:
- Inregistrator digital stand alone, tip DVR HV 4132 cu 32 canale video analogice, producator
PARADOX CANADA, corespunzand normelor Comunitatii Europene;
- Camera video color compacta de exterior cu sursa alimentare, HV227, producator
PARADOX CANADA, corespunznd normelor Comunitatii Europene;
- Camera video color tip dome cu sursa alimentare DOM HV 222, producator PARADOX
CANADA, corespunznd normelor Comunitatii Europene;
- Monitor LCD, tip Vista Monitor LCD TFT Flat Screen , producator DSC CANADA,
corespunznd normelor Comunitatii Europene;
- Lentila varifocala 5-50mm TV 555DC-IR producator PARADOX CANADA

- Sursa UPS 2000VA/1200W APC smart - corespunznd normelor Comunitatii Europene;


- Rack 12 U montabil pe perete cu bara de alimentare si organizator de cablu, asamblat.

Specificatie echipamente TVCI.


Nr. OBS.
Denumire produs Tip Cant. Producator
Crt.
Inregistrator digital - DVR HV Paradox
1. 1
DVR 4132 Canada
2. HDD-ul 3 TB 1 Western Digital
Camera color dome, DOM HV Paradox
3. 28
inclusiv sursa alim. 222 Canada
Camera color de Paradox
4. HV227 3
exterior Canada
Sursa alimentare in CSD 1218- CSD
5. 3
comutatie ptru camere 10A
SAMSUNG
Vista LCD
6. Monitor color 3 TECHWIN. -
TFT
Coreea
7. UPS - 3000VA-2700W APC smart 1 APC smart

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.49/63 -
49 - Page 49

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
49
confidetial
8/27/2017/3
5 - 49 -74
- 49 -/35

Rack 12 U montabil
pe perete cu bara de
8. alimentare si RACK 12U 1 Alcatel
organizator de cablu
asamblat
ICME
9. Cablu coaxial, 75ohm RG59 1200m
ROMANIA
ICME
10. Cablu alimentare CYY2x1 1200m
ROMANIA
camere
ICME
11. Cablu alimentare CYY3x2,5 200m
ROMANIA
-
12. Tub flexibil D=20mm 800m SC Instal

Specificatii de materiale.
Reteaua de interconectare intre elementele sistemului reprezinta infrastructura de cabluri
de diferite tipuri ce asigura legaturile electrice intre toate elementele instalatiei, astfel:
- interconectarea camerelor video cu unitatea digitala se realizeaza intr-o structura cu
topologie stea (toate cablurile de semnal converg catre DVR) folosind cablu coaxial cu
impedanta 75 ohm;
- interconectarea camerelor video la UPS se realizeaza folosind acceasi structura tip
stea ( cablurile de alimentare converg catre surse) folosindu-se cablu electric CYY-F 2x1 mm2 .
Camerele TV de interior se alimenteaza la surse de 12Vcc incorporate in camere sau montate
langa camere, fiind livrate odata cu camerele. Racordul la reteaua de 230Vca se realizeaza cu
cablu CSYY-F 2x1 mm2 .
Cablurile utilizate in sistemul de supraveghere video sunt specifice domeniului de
activitate si anume :
de semnal video tip RG 59, 75 Ohm, sectiune fir interior de 1 mm, ecranare si
izolatie externa ;
de alimentare camere tip CSYY-F 2x1 mm2
de alimentare tip CYY-F 3x2,5 mm2
doze conexiuni PVC 100mmX100mm, IP 44.
Traseele de cablu sunt protejate prin tub PVC tip Copex 20mm in cazul cablarii aplicat

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.50/63 -
50 - Page 50

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
50
confidetial
8/27/2017/3
5 - 50 -74
- 50 -/35

6.3.3 Descrierea zonelor protejate, TVCI.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.51/63 -
51 - Page 51

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
51
confidetial
8/27/2017/3
5 - 51 -74
- 51 -/35

Denumire zona Nr. camera Localizare Tip camera


video
Server CV1 Server DOM HV 222
Casier sef CV2 Casier sef DOM HV 222
Hol clienti CV3 Paza DOM HV 222
Birou IT CV4 Birou IT DOM HV 222
Hol clienti CV5 Usa intrare hol clienti DOM HV 222
Self banking CV6 Self banking DOM HV 222
Hol intrare Self CV7, CV9 Hol intrare Self banking DOM HV 222
banking
Operatiuni cu clienti CV8 Hol clienti DOM HV 222
Garaj masina valori CV10 Garaj masina valori DOM HV 222
Casa 2 CV11 Casa 2 DOM HV 222
Casa 1 CV12 Casa 1 DOM HV 222
Sala preluare numerar CV13 Sala preluare numerar DOM HV 222
Sala numarare CV14 Hol caserie DOM HV 222
Usa hol caserie CV15 Hol caserie DOM HV 222
Sala numarare CV16 Sala numarare DOM HV 222
Sala tezaur CV17 Tezaur DOM HV 222

Perimetru latura Vest CV18 Perete exterior tezaur HV227


Perimetru latura sud CV19 Perete exterior tezaur HV227
Terasa circulabila- CV21 Terasa circulabila director DOM HV 222
Terasa circulabila- CV22 Terasa circulabila birou 2 DOM HV 222
Terasa circulabila CV23 Terasa circulabila birou 4 DOM HV 222
Arhiva curenta CV24 Arhiva curenta DOM HV 222
Arhiva CV25 Arhiva DOM HV 222
Perimetru latura Nord CV26 Perete exterior sala HV227
intalniri
6.3.4
Amplasamentul componentelor

a. camere de exterior

CV19 supravegheaza intrare banca latura sud


CV18 supravegheaza perimetru pe latura de Vest
CV26 supravegheaza perimetru pe latura de Nord
b. camere de interior:
CV1 supravegheaza intrare server
CV2 supravegheaza intrare casier sef

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.52/63 -
52 - Page 52

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
52
confidetial
8/27/2017/3
5 - 52 -74
- 52 -/35

CV3 supravegheaza hol clienti


CV4 supravegheaza intrare birou IT
CV5 supravegheaza intrare hol clienti
CV6 supravegheaza intrare Self banking
CV7 supravegheaza hol intrare Self banking
CV8 supravegheaza zona operatiuni cu clienti
CV9 supravegheaza hol intrare Self banking
CV10 supravegheaza garaj masina valori
CV11 - supravegheaza casa 1
CV12 - supravegheaza casa 2
CV13 - supravegheaza sala preluare numerar
CV14 supravegheaza hol caserie
CV15 supravegheaza usa hol caserie
CV16 supravegheaza sala numarare
CV17 - supravegheaza tezaur
CV18 - supravegheaza terasa circulabila- scara
CV19 - supravegheaza terasa circulabila- directie
CV20 - supravegheaza terasa circulabila- secretariat
CV21 - supravegheaza terasa circulabila- birouri
CV22 - supravegheaza terasa circulabila- arhive
CV23 - supravegheaza intrare contabilitate
CV24 - supravegheaza intrare arhiva
CV25 - supravegheaza intrare arhiva curenta

6.3.5. Calculul energetic si calculul capacitatii HDD.

Evaluarea consumului instalatiei de supraveghere video TVCI.


Alimentarea cu energie electrica a sistemului se face de la reteaua electrica a locatiei.
Prin calculul energetic se urmareste determinarea capacitatii necesare a UPS pentru
realizarea unei autonomii energetice minime in lipsa tensiunii de alimentare de la retea.
Conform Hotararii nr. 1010 din 25 iunie 2004 pentru aprobarea normelor
metodologice si a documentelor prevazute la art. 69 din Legea nr. 333/2003 privind paza
obiectivelor, bunurilor, valorilor si protectia persoanelor, pentru echipamentele de televiziune cu
circuit inchis se va asigura o autonomie la inregistrare de cel putin 15 minute de la caderea
retelei de tensiune.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.53/63 -
53 - Page 53

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
53
confidetial
8/27/2017/3
5 - 53 -74
- 53 -/35

CALCULUL ENERGETIC CCTV

Tensiune Consum/
COMPONENTA alimentare buc (W) BUC Consum total (W)
DVR HV 4132 230 V 500 1 500
Sursa alimentare CSD 1218-10A 230 V 190 3 570 Din
acest
Monitor LCD 19 VISTA VLFSM19DBh 230 V 40 3 120
Multiplexor video digital DVR HV
4132 12.V 150 1 150
Camera video interior DOM HV 222,
PARADOX 12.V 23 1,5 34,5
Camera video exterior HV227 12.V 3 3.5 10.5
Carcasa termostatata 12.V 3 40 120

TOTAL 1843,712
Timp de inregistrare dupa
Consum sistem CCTV: Se va alege un UPS - 3000VA caderea retelei
Ccctv[W]1,843 Pups 30
Tcctv [min]
C cctv
1,843 43.9 min
considerent am ales o sursa neintreruptibila de tip UPS 3000VA(2700W) datorit faptului ca la
un consum de(1,843 W) reuseste sa se mentina in functiune sistemul timp de 43.9 minute
Conectarea electrica atat a camerelor video cat si a inregistratoarelor si monitoarelor
este realizata dintr-un circuit dedicat, comun cu celelalte sisteme de securitate.
Realizarea retelei este specificata in jurnalul de cabluri.

Evaluarea capacitatii HDD


Capacitatea totala (MB) = Nr de camere * Nr de ore de inregistrare * Viteza de inregistrare
(MB/h)

Viteza de inregistrare (MB/h) = bit rate / 8KB/s * 3600s


In cazul de fata pentru o rata de transfer medie de 512 kbit/s, o medie de 12 ore de
inregistrare pe zi datorita activarii optiunii de detectie la miscare si o perioada de inregistrare
de 30 de zile conform HG 1010/2004 rezulta urmatoarele:
512kbit/s = 512 / 8 KByte/s = 64 KB/s = 64 * 3600 KB/h = 230.4MB/h consum de banda pentru
fiecare camera.
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.54/63 -
54 - Page 54

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
54
confidetial
8/27/2017/3
5 - 54 -74
- 54 -/35

Capacitatea totala = 26 camere * (12 ore * 30 zile) * 230.4 MB/h viteza de inregistrare
(consum) = 26 * 360 * 230.4 = 179712 MB = 2. 2TB
S-a prevazut 1 DVR de 32 canale.
Confom cerintelor, pentru o calitate cat mai buna a inregistrarilor care sa permita
identificarea, se va monta pe DVR un HDD de 3TB.
Utilizarea functiei Video Motion Detection (inregistrare la detectie de miscare) prezinta
un avantaj din punct de vedere al optimizarii vitezei de umplere a HDD-ului, ceea ce duce la
cresterea semnificativa a perioadei de inregistrare.
Cu ajutorul unitatii se pot face prelucrari diverse asupra informatiilor colectate:
cautari de secvente;
verificarea actiunilor de interventie.
Utilizatorul poate descarca imagini de importanta majora cu ajutorul portului USB sau
pe cel de retea, in ideea vizualizarii si ulterior stocarii pe suport CD.

6.3.6. Date tehnice de catalog


Sistemul de supraveghere prin TVCI realizeaza urmarirea zonelor de importanta
deosebita, dorindu-se monitorizarea incintei obiectivului a zonelor de case; tezaur, server,
birou IT, ATM, arhive cat si cele 3 laturi ale cladirii, latura Sud, pe care este usa de acces in
locatie; latura Nord, delimitare gard gradina persoana fizica si latura Vest, fatada stradala.
Acest sistem este realizat cu 26, camere de luat vederi fixe, care supravegheaz zonele
din interiorul (23buc.)/exteriorul (3buc.) sediului BANCA TRANSILVANIA- din orasul Sebes
Stabilirea zonelor supravegheate si amplasarea echipamentelor s-a facut de comun
acord cu beneficiarul si in concordanta cu cerinele din LEGEA nr. 333/2003 si HG 1010/2004
Semnalele primite de la camerele video sunt transmise la locul de monitorizare SERVER.
Selectarea si stocarea semnalelor primite este realizata printr-un inregistrator video
digital tip DVR STANDALONE DVR HV 4132;, si sunt in concordanta cu cerinele din Normele
Tehnice IGP, care cer pastrarea imaginilor cel putin 30 de zile.
Imaginile sunt redate pe un monitor 19 color, montat la SERVER si prin intermediul
retelei locale LAN si la DIRECTOR ADJUNCT si la postul de paza. Reteaua de interconectare
intre echipamentele sistemului de supraveghere prin TVCI cste realizata cu cablu coaxial tip
RG 59 pentru partea de semnal, iar pentru alimentarea cu energie electrica cablu cupru 2x1mm.
Stabilirea zonelor supravegheate si amplasarea echipamentelor s-a facut de comun
acord cu beneficiarul si in concordanta cu cerinele din Normele Tehnice IGP..

Multiplexor analogic 32 canale DVR HV 4132


Specificatii tehnice:
Standard compresie: MPEG4
Nivele de compresie: f. Mare / mare / standard / scazuta
Triplex: inregistrare, redare, transmisie a datelor simultan
32 intrari video PAL; nivel al semnalului BNC: 1.0Vpp composite (+-10%)/75 balanced
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.55/63 -
55 - Page 55

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
55
confidetial
8/27/2017/3
5 - 55 -74
- 55 -/35

canale audio: 4 intrari; 1 iesire


rezolutie: CIF(352x288), 2CIF(704x288), 4CIF (704x576) PAL
HDD de 320 GB inclus
Capacitate stocare: nelimitata; HDD: 1 data/suprascriere
Inregistrare: nr. max. frame-uri captura: 100 CIF/sec PAL
Nr. maxim de frame-uri vizualizate 400 CIF / sec PAL
Redare inregistrari: viteza x1, x2, x3, x4, x8, x16, x32, x64, x128; posibilitate redare
mai multe canale in acelasi timp pe ecran; redare inregistrari sincronizata cu cea audio
Detectie miscare: rezolutie senzor 16x16; sensibilitate 10 pasi
Inregistrare pre-alarma: max. 5 sec; tip inregistrare: continua / miscare / alarma / panica;
Iesire BNC compozita; iesire VGA 1024x76860 Hz; port USB: 2 fata, 1 spate
Rata de captura posibila per canal: 25fps / 13 fps/ 7 fps / 3 fps / 2 fps / 1 fps PAL;
posibilitatea setarii independente a canalelor; inregistrare functie de timp
Intrari digitale: 16; iesiri digitale: 1 iesire de releu si 15 iesiri open collector
Backup: CD-ROM / DVD-ROM / USB / retea
Interfata PTZ: RS-485: 1; RS-232: 1; interfata RETEA: RJ-45
Zoom digital in timp real
Internet: RJ45, Ethernet; nr. max. clienti: 16; suporta DHCP si DDNS; conferinta audio
Nr. max. camere si conexiuni: 16x16; posibilitate notificare eveniment via e-mail
Functie watermark asigura autenticitatea inregistrarilor; format fisier de backup: AVI
Interfata grafica: cu Alpha blending: meniuri in mai multe limbi
Interfete de control: tastatura / tast.control PTZ / telecomanda
Program client: vizualizare prin browser; supraveghere de la distanta a inregistrarii /
arhivei; modificarea setarilor dvr-ului de la distanta, de pe statia client
Evenimente: sursa evenimentului: intrari digitale / detectie / miscare / pierdere semnal / pierdere HDD
Actiuni, functie de eveniment: inregistrare / iesiri digitale / notificare e-mail / inregistrare in
jurnal evenimente / anuntare client / atentionare tip buzz / popup video
Watch dog; detectarea inchiderii automate a aplicatiei; revenire la setarile implicite in caz de incidente
Posibilitatea revenirii la setarile din fabrica; meniuri in mai multe limbi; suporta setare
orara GMT; schimbare automata ora iarna / vara
Cautare: dupa calendar; functie de timp; dupa eveniment

Camera video color de interior DOM HV 222


Specificatii tehnice:
Camera de interior, mini-dome
Color CCD sensor
Iluminare minima: 0.6Lux/F2.0
Numar pixeli: 512x582 px PAL
Dim: 100x60; greutate: 345g
Raport semnal / zgomot (S/N): peste 48dB (AGC off)
Iris electronic: 1/60(1/50) la 1/100,000s
Mod IRIS: AES
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.56/63 -
56 - Page 56

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
56
confidetial
8/27/2017/3
5 - 56 -74
- 56 -/35

Balans de alb: ATW


Lentila: f3.6mm/F2.0
Unghi lentila 70; AGC
Iesire video: 1.0 Vp-p compozita
alimentare: DC12V; consum: 100 mA
Camera video color de exterior HV227
Specificatii tehnice:
Camera IR noapte/zi
Carcasa rezistenta la intemperii (standard IP68)
Iluminare minima: 0.6Lux / F2.0, 0Lux (15m cu IR)
Numar pixeli: 512(h)x582(v) px PAL
Dim: 100x65x63.8mm; greutate: 345g
Raport semnal/zgomot (S/N): peste 48dB (AGC off)
Iris electronic: 1/60(1/50) la 1/100,000s
Mod IRIS: AES
Balans de alb: ATW
Lentila: f3.6mm/F2.0
Unghi lentila 70
AGC; iesire video: 1.0 Vpp compozita; 75
Raza IR efectiva: 15m
Alimentare: DC12V; consum: 100mA (350mA (IR on)

Lentila varifocala 5-50mm TV 555DC-IR


Specificatii tehnice:
Lentila zi/noapte 1/3
DC Iris
Distanta focala: 5-55mm; 11x; F1.4-360
Focus manual; Zoom: manual
Iris: IG (Auto Close System)
Distanta minima fata de obiect: 0.3m la 5mm si 0.8 la 55mm
Temp. de operare: -10 ~ + 50
Unghi de vizualizare: 53.1x40.04.8x3.6
CS Mount

Monitor video color Vista Monitor LCD TFT Flat Screen DSC CANADA
Specificatii tehnice:

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.57/63 -
57 - Page 57

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
57
confidetial
8/27/2017/3
5 - 57 -74
- 57 -/35

-19 Flat Screen CCTV Monitors


1280x1024 pixels
culoare: alb
multi standard
Audio; Video; RGB; Y/C
Contrast 550:1;
Luminozitate: 270cd/m2;
Culori: 16.2 milioane;
Alimentare: 96-264V AC/12V DC
420x1902x431.5 (inc base)
Kit control DVR - C VIDEO-STRIMING - 1 bucata
Sursa alimentare in comutatie ptru camere CSD 1218-10A
Alimentare : AC-90-260V,50-60Hz
Iesiri alimentare 18x0,0,50 A 12VDC
Total10A,max 1,1A/canal
Sursa neintreruptibila tip UPS APC Smart- UPS 3000VA LCD 230V-1 bucata
Rack 19 cu accesorii + tablou de alimentare rack- 1 bucata
Mufe BNC - 52 bucati
Cabluri de legatura si interconectari
Cablurile de legatura sunt cabluri speciale pentru transmisii video, ecranate. Acestea vor fi
montate prin canalet, atasate direct pe perete in canal cablu tip MCSE1 MCSE3 sau prin tub
PVC-IPEY 20mm.
Alimentarea cu energie electrica
Alimentarea cu energie electrica se face in principal de la reteaua de 230V/50Hz.
UPS-ul, se alimenteaza direct de la reteaua electrica de 230V/50Hz.
Inregistratorul video digital-DVR-ul, monitorul LCD-TFT, camerele video cat si carcasele
termostatate ale camerelor video se alimenteaza in tampon de la reteaua electrica, prin UPS-
ul de 3000VA, aferent instalatiei, care este astfel dimensionat, ca la caderea tensiuni retelei
principale de alimentare sa tina sub tensiune instalatia de TVCI, minim 30 minute.
Consideratii generale privind sistemul de supraveghere video prin televiziune cu circuit
inchis
Conform normelor internationale si cerintelor IGPM Bucuresti, sistemul de supraveghere
video prin televiziune cu circuit inchis trebuie sa cuprinda in mod obligatoriu urmatoarele:
-Protectie mecanica completa;
-Intretinere documentata si regulata de un service autorizat si specializat;
-Sistem atestat de asiguratori;
Pentru fiecare camera se poate seta rata de inregistrare in functie de importanta si
evenimentele aparute: detectia de miscare, eveniment datorat utilizatorului, semnal primit de
la senzorii conectati la sistem, modul alarma, pierdere de semnal (imagini anterioare pierderii
semnalului).
Redarea imaginilor inregistrate (playback) se poate face atat local (de pe statia pe care
acestea sunt stocate) cat si la distanta (remote) de pe o alta statie aflata in retea. De
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.58/63 -
58 - Page 58

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
58
confidetial
8/27/2017/3
5 - 58 -74
- 58 -/35

asemenea este posibila vizualizarea in timp real a camerelor aflate pe alte statii din retea.
Imaginile inregistrate pot fi salvate sau convertite in formate foarte utilizate gen .avi precum si
in imagini statice, acestea din urma putind fi tiparite.
Marea majoritate a inregistratoarelor digitale uziteaza ca si standard de compresie H264
acesta optimizand la maxim capacitatea de stocare. Deoarece acest tip de compresie face uz
de diferenta dintre imagini successive se ia in calcul rata de transfer (bit rate) a camerei.

6.3.7.JURNAL DE CABLU, TVCI.


Nr. Crt. COD CABLU DE LA PRIN PANA LA TIP CABLU
1 TV1 DVR - CV 1 RG 59
2 TV2 DVR - CV 2 RG 59
3 TV3 DVR - CV 3 RG 59
4 TV4 DVR - CV 4 RG 59
5 TV5 DVR - CV 5 RG 59
6 TV6 DVR - CV 6 RG 59
7 TV7 DVR - CV 7 RG 59
8 TV8 DVR - CV 8 RG 59
9 TV9 DVR - CV 9 RG 59
10 TV10 DVR - CV 10 RG 59
11 TV11 DVR - CV 11 RG 59
12 TV12 DVR - CV 12 RG 59
13 TV13 DVR - CV 13 RG 59
14 TV14 DVR - CV 14 RG 59
15 TV15 DVR - CV 15 RG 59
16 TV16 DVR - CV 16 RG 59
17 TV17 DVR - CV 17 RG 59
18 TV18 DVR - CV 18 RG 59
19 TV19 DVR - CV 19 RG 59
20 TV20 DVR - CV 20 RG 59
21 TV21 DVR - CV 21 RG 59
22 TV22 DVR - CV 22 RG 59
23 TV23 DVR - CV 23 RG 59
24 TV24 DVR - CV 24 RG 59
25 TV25 DVR - CV 25 RG 59
26 TV26 DVR - CV 26 RG 59
27 TVA1 TES UPS CYY-F 3x1,5mm
28 TVA2 UPS DVR CYY-F 3x1,5mm
29 TVA3 UPS M1 CYY-F 3x1,5mm
30 TVA4 UPS M2 CYY-F 3x1,5mm
31 TVA5 UPS M3 CYY-F 3x1,5mm
32 TVA6 UPS CV 1 CYY-F 2x1mm
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.59/63 -
59 - Page 59

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
59
confidetial
8/27/2017/3
5 - 59 -74
- 59 -/35

33 TVA7 UPS CV 2 CYY-F 2x1mm


34 TVA8 UPS CV 3 CYY-F 2x1mm
35 TVA9 UPS CV 4 CYY-F 2x1mm
36 TVA10 UPS CV 5 CYY-F 2x1mm
37 TVA11 UPS CV 6 CYY-F 2x1mm
38 TVA12 UPS CV 7 CYY-F 2x1mm
39 TVA13 UPS CV 8 CYY-F 2x1mm
40 TVA14 UPS CV 9 CYY-F 2x1mm
41 TVA15 UPS CV 10 CYY-F 2x1mm
42 TVA16 UPS CV 11 CYY-F 2x1mm
43 TVA17 UPS CV 12 CYY-F 2x1mm
44 TVA18 UPS CV 13 CYY-F 2x1mm
45 TVA19 UPS CV 14 CYY-F 2x1mm
46 TVA20 UPS CV 15 CYY-F 2x1mm
47 TVA21 UPS CV 16 CYY-F 2x1mm
48 TVA22 UPS CV 17 CYY-F 2x1mm
49 TVA23 UPS CV 18 CYY-F 2x1mm
50 TVA24 UPS CV 19 CYY-F 2x1mm
51 TVA25 UPS CV 20 CYY-F 2x1mm
52 TVA26 UPS CV 21 CYY-F 2x1mm
53 TVA27 UPS CV 22 CYY-F 2x1mm
54 TVA28 UPS CV 23 CYY-F 2x1mm
55 TVA29 UPS CV 24 CYY-F 2x1mm
56 TVA30 UPS CV 25 CYY-F 2x1mm
57 TVA31 UPS CV 26 CYY-F 2x1mm

LEGENDA:
DVR Digital video recorder
CV camera de luat vederi
TES tablou electric de securitate
UPS sursa neintrerupta de tensiune

6.4. Subsistem intercomunicatii de securitate


6.4.1 Generalitati
Subsistemul de intercomunicatii are in componenta un sistem de interfonie si
videointerfonie pentru comunicatii directe si urgente in interiorul bancii si un grup de module
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.60/63 -
60 - Page 60

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
60
confidetial
8/27/2017/3
5 - 60 -74
- 60 -/35

de comunicatii de securitate fara de care eficienta sistemului de detectie si semnalizare


efractie a bancii nu ar putea avea eficienta scontata. Aceste module preiau toata gama de
semnale ( de stare, tehnice, de alarma) si le trimit pe cai de comunicatie diferite catre
dispeceratul ce monitorizeaza obiectivul, ca acesta in caz de pericol sa intervina cu personalul
specializat. Probabilitatea de defectiune simultana la toate aceste canale de comunicatie astfel
incat sa devina inoperante este foarte mica .
6.4.2 Structura subsistemului de comunicatii si amplasarea componentelor
Are in componenta urmatoarele:
- sistem de interfonie pentru intercomunicatii tip CM801 produs de Commax CANADA
- sistem videointerfon intre casierie si agentii pentru transport valori. In acest sens s-a
prevazut un kit Videointerfon tip CDV-50P produs de Commax CANADA format din
videointerfon de exterior la intrarea in SAS si un posturi interioarr videointerfon la: portar,
casierie si casier sef.
- modulGS 3055-IGGW - Modul de emulare al liniei telefonice terestre (PSTN) prin
reteaua GSM;
- In cazul in care se intrerupe comunicatia terestra comuta automat pe linia GSM. Trimite
mesaje SMS: 13 mesaje SMS. SMS-urile se pot trimite la 8 numere de telefon
diferite (max 20 digiti). Comunicator Contact ID inclus, cu 4 numere de
telefon. Control de la distanta prin SMS
Subsistem interfon.
Subsistemul de interfonie contine 2 interfoane montate la cele 2 casieri de la parter
zona preluare numerar, si se realizeaza cu echipament tip master-slave: CM801 COMAX
CANADA si anume:
- unitate centrala master CM801, Commax CANADA
- unitate centrala slave CM800, Commax CANADA
- Sursa in comutatie 220V->12V; 15W ; 1.3A
Instalatia de interfon este necesara pentru ca schibul de informatii si plata banilor de catre
casiera spre client sa se faca fara un conntact direct. Casieria este protejata cu geam securizat
antiglont. .
Subsistem videointerfon.
Subsistemul de videointerfonie se realizeaza cu echipament tip CDV-50P si camera
DRC-40CK COMMAX CANADA si are urmatoarea componenta:
Cel care raspunde primul la semnal este portarul bancii, car verifica prin intermediul
videointerfonului PAVI 01 informatia primita sosire masina transport valori, apoi anunta pe
cei desemnati sa-l insoteasca pentru a permite intrarea masini de valori in garaj si preluarea
valorilor aduse de aceasta.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.61/63 -
61 - Page 61

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
61
confidetial
8/27/2017/3
5 - 61 -74
- 61 -/35

Subsistemul de interfonie mai are instalate 2 terminale pentru vizionare semnalului


primit , unul amplasat in birou sef casier de la parter si celalalt amplasat la casierie.
Aceasta instalatie face parte din sistemul comlex de securitate al bancii
- Unitate exterioara CDV-50P, Commax CANADA
- camera color DRC40CK, Commax CANADA
- unitate interioara echipata cu ecran LCD 5, Commax CANADA
- sursa in comutatie 24-29VDC, 5A, Commax CANADA
Pentru intrarea in banca a masini de transport valori, in zona garaj masina transport
valori, se solicita permisiunea prin intermediul unitatii de interfon exterioare.

Modul GPRS T2- Modul de emulare al liniei telefonice terestre (PSTN) prin reteaua
GSM;
- In cazul in care se intrerupe comunicatia terestra comuta automat pe linia GSM. Trimite
mesaje SMS: 13 mesaje SMS. SMS-urile se pot trimite la 8 numere de telefon
diferite (max 20 digiti). Comunicator Contact ID inclus, cu 4 numere de
telefon. Control de la distanta prin SMS
Modul ETH-M1- modul comunicator universal linie telefonic/IP/GPRS
Acest modul ofera subsistemului de avertizare la efracie soluii de raportare la dispecerat via
Ethernet i/sau GSM-GPRS, ca alternativ la linia telefonic; compatibil cu orice central de
alarm, capabil s raporteze n format ADEMCO Contact ID (CID); prevzut cu 4 intrri i 4
ieiri programabile, utilizate pentru raportare la distan n mod de funcionare stand-alone,
pentru interfaarea cu modele mai vechi de centrale sau pentru automatizri locale i la
distan; toate evenimentele primite de la central sau de la propriile intrri sunt transmise la
dispecerat, pe canal GSM-GPRS sau Ethernet, n funcie de programarea prioritilor de
raportare pe cele 2 canale (linia telefonic este folosit de ctre central numai ca ultim
soluie)

6.4.3. Specificatie echipamente, interfon, videointerfon

Nr. Denumire produs Tip Cant. Producator OB


Crt. S.
1. Kit interfon pentru CM801 2 Commax -
Intercomunicatii Canada
format din 2 posturi
interfon, inclusiv sursa
alim.
2. Kit videointerfon CDV-50P 1 Commax -
format din post de DRC-40CK Canada
exterior, 3 post de
interior si sursa alim.
3. Modul comunicator ETH-M1 1 Satel Polonia -
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.62/63 -
62 - Page 62

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
62
confidetial
8/27/2017/3
5 - 62 -74
- 62 -/35

universal linie
telefonic/ IP/GPRS
4. Modul comunicator GSM LT-2 1 Satel Polonia -
GSM/GPRS
5. Modul comunicator de GPRS-T2 1 Satel Polonia -
raportare GSM/GPRS

6.4.4 Date tehnice de catalog


Kit videointerfon CDV-50P DRC-40CK
Kit video-interfonie color, 1 linie: include panou exterior, cutie de montare ingropata, monitor,
sursade alimentare
- cablare pe 3 fire + coaxial
- panou exterior standard (aluminiu anodizat)
- post interior video-interfonie digital LOFT
- sursa de alimentare 12Vca/1.5A - 18Vcc/1A
- sistem extensibil, fara sursa de alimentare suplimentara, cu inca 1 monitor sau 2 telefoane

Interfon pentru intercomunicatii CM801


- Kit intercomunicatie include posturi intercomunicatie cu rama decorativa, sursa de alimentare
- cablare pe 3 fire
- 2 x post interior pentru intercomunicatie
-2 x rama decorativa pentru post interior
-sursa alimentare 12Vca/1.5A
- sistem extensibil pana la 12 posturi interioare, fara sursa de alimentare
suplimentara

Modul GPRS -T2,


- Modul de emulare al liniei telefonice terestre
(PSTN) prin reteaua GSM
- Interfata analogica prietenoasa permite
conectarea unui post telefonic normal pe reteaua
GSM
- LED semnalizare apeluri
- LED semnalizare defecte
- 5intrari
- In cazul in care se intrerupe comunicatia
terestra comuta automat pe linia GSM
- Dual Band
- SMS/CLIP
- SMS-urile se pot trimite la 8 numere de telefon
diferite (max 20 digiti)
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.63/63 -
63 - Page 63

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
63
confidetial
8/27/2017/3
5 - 63 -74
- 63 -/35

- Comunicator Contact ID inclus, cu 4 numere de


telefon
- Control de la distanta prin SMS
- Tensiunea de alimentare: 12 VDC
- Loc pentru acumulator :2Ah/30V
- Consum : 180mA (max.)
- stand-by: 50mA
- Dimensiune: 80x57x55mm (fara antena)

ETH-M1 - Plac comunicator universal linie telefonic/IP/GPRS


- realizat pentru a oferi sistemelor de avertizare la efracie soluii de raportare la dispecerat via
Ethernet i/sau GSM-GPRS, ca alternativ la linia telefonic; compatibil cu orice central de
alarm, capabil s raporteze n format ADEMCO Contact ID (CID);
- prevzut cu 4 intrri i 4 ieiri programabile, utilizate pentru raportare la distan n mod de
funcionare stand-alone, pentru interfaarea cu modele mai vechi de centrale sau pentru
automatizri locale i la distan;
- toate evenimentele primite de la central sau de la propriile intrri sunt transmise la
dispecerat, pe canal GSM-GPRS sau Ethernet, n funcie de programarea prioritilor de
raportare pe cele 2 canale (linia telefonic este folosit de ctre central numai ca ultim
soluie);
- software GRATUIT! pentru programarea parametrilor, testare si diagnoz - Multicomm
Programmer, cu conexiune direct la PC (prin cablu de tip CrossOver) sau la distan (conexiune
Internet/Intranet sau GPRS callback);
- Tensiunea de alimentare: 12 VDC
- Consum : 120mA (max.)
- Dimensiune: 140x68x55mm

6.4.5 JURNAL DE CABLU

Nr. COD CABLU DE LA PRIN PANA LA TIP CABLU


Crt.
1. I1 IFM1 - IFS01 UTP 4x2x0,5
2. I2 IFM2 - IFS02 UTP 4x2x0,5
3. I3 SA1 - IFM1 CYY 3x1
4. I4 SA2 - IFM2 CYY 3x1
5. I5 PVIE 1 - PVI 01 UTP 4x2x0,5
6. I6 PVIE 1 - PVI 01 RG 6
7. I7 PVIE 1 - PVI 02 UTP 4x2x0,5
8. I8 PVIE 1 PVI 02 RG 6
9. I9 PVIE 1 - PVI 03 UTP 4x2x0,5
10. I10 PVIE 1 PVI 03 RG 6

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.64/63 -
64 - Page 64

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
64
confidetial
8/27/2017/3
5 - 64 -74
- 64 -/35

11. I11 TES - PI 1 CYY 3x1,5


12. I12 TES - PVIE 1 CYY 3x1,5

Unde:
PI post central interfon
IFM post abonat interfon
PVI post videointerfon
PVIE post videointerfon exterior
TES tablou electric de securitate
CLVI cutie de legaturi

7. CONDITII DE PREDARE A LUCRARII PENTRU EXPLOATARE SI


RECEPTIA LUCRARII
7.1 Conditii de receptie
Recepia preliminar a instalaiilor va consta din efectuarea verificrilor scriptice i fizice i
a msurtorilor, pentru a constata dac lucrrile au fost executate conform proiectelor ori a
modificrilor aprobate i dac au fost ndeplinite condiiile tehnice.
Verificarea scriptic se face pe baza urmtoarelor documente:
Proiectele definitive nsoite de memoriul justificativ cu toate modificrile introduse la
montaj, cu justificarea acestora (aviz proiectant, not de comand sau aviz beneficiar);
Certificate de calitate elaborate de productor;
Agremente tehnice i avize;
Procese verbale de lucrri ascunse;
Verificarea fizic va consta dintr-o examinare general a execuiei lucrrilor. Se va verifica
ndeplinirea tuturor condiiilor de funcionare. Pentru instalaiile care se ngroap sub tencuial,
verificarea calitii se efectueaz conform instruciunilor pentru lucrri ascunse.
Verificrile de calitate pentru recepia preliminar vor fi efectuate de comisia de recepie
care i va exercita atribuiile conform Regulamentul de recepie a lucrrilor de construcii i
instalaii aferente acestora aprobat prin HGR nr. 273 din 1994.
La intrarea unei faze de lucrri, respectiv la terminarea unor poriuni de instalaie, care pot
funciona sau se pot aproba independent, verificrile i probele se fac cu participarea
delegatului beneficiarului, iar rezultatele se nscriu n registrul de procese verbale.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.65/63 -
65 - Page 65

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
65
confidetial
8/27/2017/3
5 - 65 -74
- 65 -/35

La recepia final a lucrrilor, beneficiarul va solicita constructorului cartea tehnic a


lucrrii n care s fie evideniate cu cea mai mare precizie modul de execuie, eventualele
modficri acceptate de proiectant i beneficiar, inclusiv marcarea lucrrilor.
Recepia final se va face de ctre comisia de recepie care i va exercita atribuiile
conform Regulamentul de recepie a lucrrilor de construcii i instalaii aferente acestora
aprobat prin nr. 273 din 1994.
La recepia la terminarea lucrrilor se vor verifica:
cablarea sistemului din punct de vedere estetic
poziionarea echipamentelor
funcionalitatea dispozitivelor din sistem
verificare funcionalitate a sistemului
La recepia la terminarea lucrrilor firma executant va preda obligatoriu Beneficiarului
urmtoarele documente:
proiectul sistemului de detecie i avertizare incendiu;
documentaia echipamentelor instalate i instruciuni de utilizare a sistemului;
documentele care atest instruirea profesional a personalului utilizator;
jurnalul sistemului de detecie i avertizare incendiu.
n jurnalul sistemului se consemneaz evenimentele tehnice survenite n funcionarea
sa.
Pstrarea jurnalului se face de ctre beneficiarul-utilizator, la acesta avnd acces
personalul abilitat al firmei liceniate care asigur service-ul

7.2 Punerea in functiune


Verificarea calitii i funcionalitii instalaiei se va face conform prescripiilor din
documentaia tehnica a instalaiei respective.
Executantul va preda beneficiarului toate actele de atestare i verificare a calitii
lucrrilor de instalaii(procese verbale de lucrri ascunse, certificate de calitate a
materialelor, buletinelor de ncercri, etc.).
Aceste documente vor fi folosite la ntocmirea crii tehnice a construciei.
n perioada de probe se vor face toate remedierile defectelor de execuie sau de
materiale, dup care probele se vor relua.
Reparaiile datorate unor defecte de execuie sau unor defecte ale materialelor n
perioada de garanie, se vor efectua prin grija i cu costurile suportate de executant .

7.3 Exploatarea instalaiilor


Proprietatul sau o alta persoan avnd control n aceea parte a cldirii care conine
instalaia, este responsabil pentru:
Asigurarea conformitaii iniiale i continue a instalaiei sau sistemului;

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.66/63 -
66 - Page 66

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
66
confidetial
8/27/2017/3
5 - 66 -74
- 66 -/35

Scrierea procedurii pentru abordarea diferitelor alarme, avertizri i a altor


evenimente aparute n instalaie sau sistem;
Antrenarea ocupanilor pentru recunoaterea diferitelor situaii, alarme i pentru
evacuare;
Pastrarea instalaiei sau sistemului n cele mai bune condiii de funcionare;
Prevenirea alarmelor false, prin luarea de msuri adecvate pentru mpiedicarea
activrii detectoarelor prin operaii de sudare, tiere metale, fumat, nclzit,
evacuare gaze, etc. (pt instalaia de detecie i avertizare la incendii);
Asigurarea c instalaia sau sistemul este ntreinut la intervale corespunzatoare
dupa apariia unui defect sau alt eveniment care poate afecta sistemul;
inerea unui registru de evidena a interveniilor la sistem i nregistrarea tuturor
evenimentelor;
Numirea uneia sau mai multor persoane pentru ndeplinirea acestor funcii.
Numele lor trebuie scrise n registrul de eviden a interveniilor la sistem;
Jumalul instalaiei trebuie inut ntr-un loc accesibil persoanelor autorizate i trebuie
efectuate nregistrri privind toate evenimentele sistemulu

8. GARANTII
Echipamentele utilizate pentru sistemul de avertizare la incendiu vor fi avizate conform
SR-EN 54 (grup de standarde).
Toate echipamentele vor avea o garanie de minim 12 luni.

9. MODUL DE ASIGURARE A MENTENANTEI


9.1 Conditii generale privind efectuarea mentenantei
Pentru buna funcionare i siguran a sistemelor de securitate, este obligatorie
verificarea periodic a instalaiilor i mijloacelor tehnice de supraveghere i alarmare.
Verificrile tehnice periodice vor include toate operaiunile necesare pentru a menine
operaional i n stare de funcionare sistemul de detecie i avertizare incendiu, urmrindu-se
dac, sistemul este funcional n totalitatea sa, elementele de detecie au suferit deteriorri,
deplasri ori mascri care reduc din zona supravegheat i asigur transmitere la distan a
semnalelor, comanda sistemelor de protectie la incendiu.
Beneficiarul va efectua verificari saptamanale prin actionarea butoanelor manuale de
alarmare.
Beneficiarul este obligat sa anunte, societatea care efectueaza mentenanta, orice
anomalie privind functionarea instalatiei.
Toate verificrile periodice i toate interveniile se vor meniona ntr-un jurnal ce va
cuprinde verificrile tehnice periodice,evenimentele care au influenat funcionarea sistemului
consemnndu-se :
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.67/63 -
67 - Page 67

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
67
confidetial
8/27/2017/3
5 - 67 -74
- 67 -/35

- data i ora apariiei defectului


- data i ora remedierii
- componentele reparate ori nlocuite
persoanele care au executat lucrarea i semntura
9.1.2 Operatii executate de catre societatea licentiate, care efectueaza mentenanta
se controleaz registrul sistemului de detectie
se executa verificarea vizuala a sistemelor
se verific tensiunile de alimentare ale sistemelor
se examineaz conexiunile de la acumulatori;
se nlocuiesc acumulatorii care au depit perioada de funcionare
recomandat de productor;
se inspecteaz vizual centrala sistemului pentru urme de umezeal sau
alte semne de deteriorare;
se execut toate controalele i testele precizate de instalator, furnizor sau
productorul elementelor sistemului;
se informeaz la client de existena sau nu a unor modificri intervenite
asupra sistemului
se verific buna funcionare a tuturor senzorilor;
se nlocuiesc elementele de sistem pe care le consider la limita de
funcionare i care pot cauza alarme false
dac sistemul este conectat la un dispecerat zonal de monitorizare,
acesta va fi informat despre executarea ntreinerii i se va verifica modul
de transmitere a semnalelor ctre acesta

10. MASURI SPECIFICE DE SECURITATE A MUNCII

Documentaia de proiectare a fost astfel ntocmit nct s permit executarea i


utilizarea instalaiei proiectate n condiiile n care la o exploatare normal a sistemului s se
previn accidentele de munc, precum i mbolnvirile profesionale
10.1 Factorii de risc la execuia lucrrii
Factorii de risc avui n vedere la elaborare documentaiei sunt urmtorii:
Lucru la nlime.
Electrocutarea prin atingere indirect sau direct.
Contact cu corpuri ascuite.
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.68/63 -
68 - Page 68

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
68
confidetial
8/27/2017/3
5 - 68 -74
- 68 -/35

Contractul de execuie va cuprinde i clauze privind securitatea muncii cu rspunderile parilor

10.2 Msurile individuale i colective de securitatea muncii la execuia lucrrii


Fa de factorii de risc estimai pentru execuia lucrrii indicai mai sus, se impun
urmtoarele sortimente de mijloace individuale de protecia muncii care pot fi acordate conform
Ord.225/21.07.1995 a MMPS:
Casc de protecie
Mnui de protecie
Salopet de protecie
Personalul de execuie va utiliza numai utilaje sigure din punct al securitii muncii, care
au certificate de conformitate, sunt cumprate cu declaraie de conformitate relativ la
securitatea muncii i sunt marcate de conformitate pentru securitatea muncii. Sculele utilizate
vor avea mnere electroizolante, vor fi apucate numai de zona izolat, scrile care se vor
folosi trebuie sa fie electroizolante iar personalul trebuie s fie dotat i s utilizeze
echipamentul individual de protecie, respectnd principiului ,,cel puin dou mijloace
electroizolante nseriate pe calea de curent.
Echipamentele portabile i uneltele manuale utilizate vor respecta cap.4.8 din NGPM-
1996.
Executantul va utiliza pentru manevre n instalaiile electrice de joas tensiune numai
personal autorizat conform NS 65-1997.
Ca mijloace colective de protecie se recomand: semnalizarea locurilor periculoase i
atenionarea vizibil a lor cu plcue de semnalizare, instructajul specific i periodic de
protecia muncii la locul de munc, elaborarea unor instruciuni proprii de securitatea muncii,
elaborarea i respectarea unui program de securitate i sntate n munc, datarea locurilor
de munc cu trus sanitar de prim ajutor, utilizarea de scule i utilaje certificate, controlul
permanent n vederea verificrii ca au fost luate masurile privind respectarea regulilor de
securitatea muncii, etc.
La tablourile electrice de joas tensiune, pentru evitarea electrocutrii prin atingerea
indirect s-au aplicat dou masuri de protecie: una principal care este legarea la nulul de
protecie i o msur suplimentar care este conectarea la instalaia de legare la pmnt. n
partea desenat a proiectului se indica aceste masuri de protecie.
n timpul execuiei este interzis folosirea instalaiilor i a echipamentelor improvizate
sau necorespunztoare.
Pentru lucrul la nlime, conform NS 12-1995, executantul va folosi numai personal
atestat medical pentru acesta i va utiliza utilaje(platforme, scrii, etc.) sau mijloace individuale
de protecie(centuri, etc.) pentru lucru la nlime, dup caz.
n magaziile de pe antier, executantul va aplica normele de protecia muncii pentru
transportul prin purtare cu mijloace nemecanizate i depozitarea materiilor, NS 57-1997.
La manevre n instalaiile electrice scoase de sub tensiune se vor aplica prevederile art.
369 i 370 din NGPM-1996. Nu se vor face manevre cu instalaii electrice aflate sub tensiune.
Prin ,, manevr se nelege un ansamblu de operaii care conduce la schimbarea
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.69/63 -
69 - Page 69

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
69
confidetial
8/27/2017/3
5 - 69 -74
- 69 -/35

configuraiei unei instalaii electrice prin acionarea unor aparate de comutaie (NS 65-1997
anexa 1).
Pe antier i n interiorul construciilor n lucru se vor utiliza tablouri de distribuie n
execuie capsulat sau tablouri nchise n cutii prevzute cu u i cheie, conform I7/02
art.16.6.
Toate echipamentele electrice cu tensiuni periculoase trebuie legate la instalaia de
legare la nul de protecie conform STAS 12604/4-89 i STAS 12604/5-90.
Montarea echipamentelor tehnice electrice i realizarea instalaiilor electrice trebuie s
se desfoare n aa fel nct s nu se modifice concepia de proiectare. n cazuri speciale,
modificrile trebuie s se fac numai cu acordul scris al proiectantului.
n cadrul documentaiei, proiectantul a ales echipamente tehnice care sunt sigure din punct de
vedere al securitii muncii i se vor livra cu declaraie de conformitate conform Legii nr.
90/1996
10.3 Obligaiile executantului
Executantul rspunde de realizarea lucrrilor de instalaii n condiii care s asigure
evitarea accidentelor de munc. n acest scop este obligat:
S analizeze documentaia tehnic din punct de vedere al securitii muncii;
S aplice prevederile cuprinse n legislaie din punct de vedere al securitii muncii;
S execut toate lucrrile, n scopul exploatrii ulterioare a instalaiilor n condiii
depline de securitii muncii, respectnd normele/instruciile/standarde;
S remedieze toate deficienele constatate cu ocazia probelor i recepiei astfel ca
lucrarea executat s poat fi utilizat n condiii de securitate maxim posibil;
S utilizeze pe antier msurile individuale i colective de securitatea muncii astfel
ca s se evite sau s se diminueze pericolele de accidente sau mbolnviri
profesionale;
S utilizeze pentru manevre n instalaiile electrice numai electriceni autorizai
conform NS 65-1997;
S aplice n totalitate cerinele art.208 din NGPM-1996;

10.4 Obligaiile beneficiarului


Beneficiarul rspunde de preluarea i apoi exploatarea lucrrilor de instalaii n condiii
care s asigure securitatea muncii. n acest scop este obligat:
S analizeze proiectul din punct de vedere al securitii muncii;
S respecte i s aplice toate normele i normativele de securitate a muncii;
S respecte instruciunile de securitate a muncii ale echipamentelor livrate;
S fac analiza factorilor de risc de accidente i s ia masurile corespunztoare;
Pentru lucrrile de instalaii care se execut n paralel cu desfurarea procesului de
producie, s ncheie cu executantul un protocol anexat la contract n care s
delimiteze zonele de lucru pentru care rspunderea privind asigurarea msurilor de
securitate a muncii revin executantului
S aplice cerinele art.209 din NGPM-1996;
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.70/63 -
70 - Page 70

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
70
confidetial
8/27/2017/3
5 - 70 -74
- 70 -/35

n exploatare s existe obligatoriu documentele specificate n art.356 din NGPM-


1996;
S prevad mijloace de prim ajutor;
Pentru personalul care lucreaz cu video terminale s aplice NS 37-1996 i n
special art.6 i 7 care prevede obligativitatea examenului medical oftalmologic i
utilizarea de ochelari/ecrane de protecie, dac e cazul;
S prevad i s aplice msuri de prevenire i stingere a incendiilor;
S ntocmeasc proceduri de intervenie pentru caz de criz sau dezastre i s aib
pregtite echipe de intervenie, antrenate i dotate corespunztor;
S prevad sumele necesare pentru realizarea msurilor de securitatea muncii;
S-i organizeze activitatea de securitate i sntate n munc conform NGPM-
1996;
Recepia i punerea n funciune a instalaiei se va face numai dup ce s-a constat i
consemnat, cu avizul proiectantului, c s-au respectat normele de securitate a
muncii;
S nu permit accesul persoanelor neautorizate n instalaiile electrice;
S respecte n funcionare prevederile cap.4.5 din NGPM-1996;
Beneficiarul trebuie s verifice c instalaia de legare la pmnt este corespunztoare,
s se ngrijeasc s fac msurtori periodice a rezistenei prizei de pmnt i s obin
buletine de msurtori care atest c este n parametrii normali, conform legislaiei.
n locurile cu pericol de incendiu, beneficiarul trebuie s ia msuri de protecie mpotriva
descrcrilor statice, conform art. 347 din NGPM-1996;

10.5 Legislaia de securitate a muncii

La ntocmirea lucrrilor de proiectare s-a inut seama de legislaia de securitatea muncii


aflat n vigoare. Se atrage atenia executantului lucrrii i n special beneficiarului, ca utilizator
al instalaiei proiectate, c trebuie s respecte ntocmai aceast legislaie din motive morale i
datoria rspunderii juridice care prevede ca neluarea vreuneia din masurile prevzute de
dispoziiile legale referitoare la protecia muncii sau nerespectarea de ctre orice persoan a
msurilor stabilite cu privire la protecia muncii, constituie infraciune si se pedepsete ca
atare.
Dam mai jos o list restrns a acestei legislaii de care s-a inut seama la proiectare i
care trebuie completat de executant i beneficiar cu normele specifice corespunztoare.
Beneficiarul i executantul trebuie de asemenea s elaboreze i instruciuni proprii de
securitatea muncii, specifice instalaiei.
-Legea 90/1996- Norme generale de protectia muncii
-Legea 319/2006- Legea securitatii si sanatatii in munc
-HG 1425/2006 pentru aprobarea normelor metodologice de aplicare a prevederilor
legii securitatii si sanatatii in munca nr. 319/2006.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.71/63 -
71 - Page 71

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
71
confidetial
8/27/2017/3
5 - 71 -74
- 71 -/35

-HG 300/2006 - privind cerintele minime de securitate si snatate pentru santierele


temporare sau mobile.
-HG 1876/2005 privind cerintele minime de securitate si snatate referitoare la
expunerea lucratorilor la riscurile generate de vibratii
-HG 493/2006 - privind cerintele minime de securitate si snatate referitoare la
expunerea lucratorilor la riscurile generate de zgomot
-HG 971/2006 - privind cerintele minime pentru semnalizarea de securitate si/sau de
snatate la locul de munca.
-HG 1048/2006 - privind cerintele minime de securitate si snatate pentru utilizarea de
catre lucratori a echipamentelor individuale de protectie la locul de munca.
-HG 1091/2006 - privind cerintele minime de securitate si snatate pentru locul de
munc.
-HG 1146/2006 - privind cerintele minime de securitate si santate pentru utilizarea in
munc de catre lucratori a echipamentelor de munc.
-Ordin 753/2006 privind protectia tinerilor in munc.
-SR EN 12154/2006 Instalatii electrice in constructii. Partea 4:Masuri pentru
asigurarea securitatii. Capitolul 47:Utilizarea de protectie pentru asigurarea securitatii.
Sectiunea de protectie impotriva socurilor electrice
-SR EN 12154/2006 Instalatii electrice in constructii. Partea 4:Masuri de protectie
pentru asigurarea securitatii. Capitolul 47:Utilizarea masurilor de protectie pentru asigurarea
securitatii. Sectiunea 470:Generalitati. Sectiunea 471:Masuri de protectie impotriva socurilor
electrice.
-SR EN 12179:2006 - Instalatii electrice in constructii. Partea 4:Protectie pentru
asigurarea securitatii. Capitolul 46:Sectionare si comand.
-SR EN 12274-7:2006 - Instalatii electrice in constructii.Partea 4:Protectie pentru
asigurarea securitatii. Capitolul 44:Protectie impotriva supratensiunilor de origine atmosferica
sau de comutatie.
-SR EN 12326-1:2006 - Instalatii electrice in constructii. Partea 4:Protectie pentru
asigurarea securitatii. Capitolul 43:Protectia impotriva supracurentilor.
- SR EN 12697-41:2006 - Instalatii electrice in constructii. Partea 4:Masuri de protectie
pentru asigurarea securitatii. Capitolul 41:Protectia impotriva socurilor electrice.
- SR EN 10224/A1:2006*- Sisteme de detectare si de alarma la incendiu. Partea 3 :
Dispozitive sonore de alarma la incendiu.
- SR HD 384.7.702 S2 CEI 60364-7-702:2004 - Protectia impotriva trasnetului. Partea
1:Principii generale.
- SR HD 60364-7-703:2006 - Vocabular electrotehnic international. Partea 195:Legare
la pamant si protectie impotriva socurilor electrice.
- SR.CEI/TS 60479:2006 - Vocabular electrotehnic international. Partea 195:Legare la
pamant si protectie impotriva socurilor electrice.
-Normativ I7/2002
-Normativ I18-1/2001
-STAS 12604-4/89, -5/90 - Protectia impotriva electrocutarii
Cod proiect TEMA Beneficiar Intocmit Breazu Ioan
Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.72/63 -
72 - Page 72

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
72
confidetial
8/27/2017/3
5 - 72 -74
- 72 -/35

-STAS 2612/87 - Protectia impotriva electrocutarii. Limite admise-STAS 4102/85 - Piese


pentru instalatii de protectie prin legare la pamant sau la nul. in vigoare specifice lucrarilor
proiectate:
- Legea nr. 307/2006 privind apararea impotriva incendiilor;
- HGR nr. 1739/2006 pentru aprobarea categoriilor de constructii si amenajari care se
supun avizarii si/sau autorizarii privind securitatea la incendiu;
- HGR nr. 537/2007 privind sanctionarea contraventionala in domeniul apararii impotriva
incendiilor;
- OMAI nr. 712/2005 pentru aprobarea Dispozitiilor generale privind instruirea
salariatilor in domeniul situatiilor de urgenta modificat si completat cu OMAI 786/2005;
- OMAI nr. 130/2007 pentru aprobarea Metodologiei de elaborare a scenariilor de
securitate la incendiu;
- OMAI nr. 163/2007 pentru aprobarea normelor generale de aparare impotriva
incendiilor;
- OMIRA nr. 252/2007 pentru aprobarea Metodologiei de atestare a persoanelor care
proiecteaza, executa, verifica, intretin si/sau repara sisteme si instalatii de aparare
impotriva incendiilor, efectueaza lucrari de termoprotectie si ignifugare, de verificare,
intretinere si reparare a autospecialelor si/sau a altor mijloace tehnice destinate
apararii impotriva incendiilor;
- OMAI nr. 132/2007 pentru aprobarea Metodologiei de elaborare a Planului de analiza
si acoperirea riscurilor si a Structurii-cadru a Planului de analiza si acoperirea a
riscurilor;
- OMAI nr. 210/2007 pentru aprobarea Metodologiei privind identificarea, evaluarea si
controlul riscurilor de incendiu;
- OMAI nr. 105/2007 pentru modificarea OMAI 585/2005 pentru aprobarea unor masuri
privind functionarea Comisiei de recunoastere a organismelor pentru atestarea
conformitatii produselor pentru constructii cu rol in satisfacerea cerintei de securitate la
incendiu;
- OMAI nr. 106/2007 pentru aprobarea Criteriilor privind stabilirea consiliilor locale si
operatorilor economici care au obligatia de a angaja cel putin un cadru tehnic sau
personal de specialitate cu atributii in domeniul apararii impotriva incendiilor;
OMAI nr. 1474/2006 pentru aprobarea Regulamentului de planificare, organizare,
pregatire si desfasurare a activitatii de prevenire a situatiilor de urgenta.
Obiectivele proiectate nu se vor pune in functiune partial sau total nici macar pe timp
limitat , inainte de executarea integrala a tuturor instalatiilor si a constructiilor si numai dupa
asigurarea tuturor masurilor de tehnica securitatii si igiena muncii in vigoare si obtinerea
autorizatiei de constructie si functionare.
In cazul in care beneficiarul si constructorul considera ca masurile luate prin proiect
nu sunt suficiente, vor cere odata cu observatiile ce trebuie facute la proiect si in acelasi
termen legal, sa se introduca in proiect masurile suplimentare de tehnica securitatii si igiena
muncii pe care le considera necesare.

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.73/63 -
73 - Page 73

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
73
confidetial
8/27/2017/3
5 - 73 -74
- 73 -/35

De asemenea se va asigura instructajul personalului de exploatare si executie


pentru a se preintampina eventuale accidente sau imbolnaviri , facandu-se si verificarile
medicale necesare.
Beneficiarul va asigura personalului de exploatare toate echipamentele si mijloacele
de protectia muncii necesare prevazute in normativele in vigoare.
Beneficiarul si constructorul vor intocmi instructiuni proprii, speciale si specifice
tuturor locurilor de munca ce considera ca au un caracter deosebit sau pentru care normele
existente nu dau prescriptii suficiente care sa conduca la securitatea investitiei si a
personalului

NOT:

Solicitam beneficiarului modificarea proiectului de constructie prin anularea ferestrei


intre Garaj masina transport valori si Hol intrare Self Banking

ntocmit Verificat Aprobat


Ing Breazu Ioan Ing Breazu Ioan Ing Breazu Ioan

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan
Pag.74/63 -
74 - Page 74

8/27/2017
breazu Page
Proiect nr :01.2016 Data 29. 11. 2016
74
confidetial
8/27/2017/3
5 - 74 -74
- 74 -/35

Cod proiect TEMA Beneficiar Intocmit Breazu Ioan


Denumire Sistem tehnic de securitate BANCA
Verificat Breazu Ioan
proiect TRANSILVANIA Aprobat Breazu Ioan

You might also like