KBG121000 12V 100Ah(10hr)

Gel battery shows some distinctive advantages over flooded battery or AGM battery,
such as super thermal stability, high deep discharge capability, good recovery from
deep discharge , even if the battery is left discharged for three days, it will recover
to 100% of capacity. With the above-mentioned advantages, the gel battery has
long service life, specially suitable for motive power applications, such as golf trailer,
sruubber, folklift,etc.The deep discharge cycles increased 50% as compared with
the AGM battery.

Battery Construction
Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte
Raw material Lead dioxide Lead ABS ABS Rubber Copper PVC Gelled acid

General Features Performance Characteristics


Nanometer SiO 2 and H 2 SO 4 gelled Nominal Voltage 12V
electrolyte technology for efficiency Number of cell 6
gas recombination of up to 99% and
Design Life 12 years
freedom from electrolyte maintenance
or water adding. Nominal Capacity 77oF(25oC)
Not restricted for air transport-complies 20 hour rate (5.00A, 10.8V) 100Ah
with IATA/ICAO Special Provision A67.
10 hour rate (9.50A, 10.8V) 95.0Ah
UL-recognized component.

Can be mounted in any orientation. 5 hour rate (17.4A, 10.5V) 87.0Ah


Computer designed lead, calcium tin alloy 1 hour rate (65.2A, 9.6V) 65.2Ah
grid for high power density. Internal Resistance
Long service life, float or cyclic
Fully Charged battery 77oF(25oC) 5mOhms
applications.
Maintenance-free operation.
Self-Discharge
Low self discharge. 3% of capacity declined per month at 20oC(average)
Case and cover avaiable in both standard Operating Temperature Range
and flame restardant ABS. Discharge -20~60oC
Dimensions and Weight Charge -10~60oC
330 / 12.99 Storage -20~60oC
Length(mm / inch)
o o
Max. Discharge Current 77 F(25 C) 900A(5s)
Width(mm / inch) 171 / 6.73
Height(mm / inch) 215 / 8.46 Short Circuit Current 2100A
Total Height(mm / inch) 220 / 8.66 Charge Methods: Constant Voltage Charge 77oF(25oC)
Approx. Weight(Kg / lbs) 32 / 70.5
Cycle use 14.4-14.7V
Maximum charging current 30A
Temperature compensation -30mV/oC
Standby use 13.6-13.8V
Temperature compensation -20mV/oC

Discharge Constant Current (Amperes at 77oF25oC)


End Point
5min 10min 15min 30min 45min 1h 3h 5h 10h 20h
Volts/Cell
1.60V 298 220 180 105 78.9 65.2 27.6 18.9 9. 75 5.20
1.65V 281 212 173 101 77.1 61.6 27.4 18.2 9. 70 5.15
1.70V 257 192 159 93.6 71.5 60.6 26.9 17.9 9. 65 5.10
1.75V 230 180 148 90.7 69.9 59.6 26.6 17.4 9. 60 5.05
1.80V 210 168 139 88.7 68.6 56.5 25.1 17.1 9. 50 5.00

Discharge Constant Power (Watts at 77oF25oC)


End Point
5min 10min 15min 30min 45min 1h 2h 3h 5h
Volts/Cell
1.60V 520 376 311 194 147 122 69.7 52.3 35.6
1.65V 491 364 306 183 143 116 66.9 50.7 35.2
1.70V 454 346 290 178 134 112 65.9 50.4 34.8
1.75V 419 339 285 173 131 109 63.7 48.6 34.2
1.80V 394 316 271 167 128 102 61.7 48.0 33.8

(Note)The above characteristics data are average values obtained within


three charge/discharge cycles not the mimimum values.
page1 of 2
KBG121000 12V 100Ah

Discharge characteristic (25OC) Constant voltage charging


o
characteristic (0.30CA,25 C)

CHARGED VOLUME
Battery voltage(V)

15.8A 9A 4.73A CHARGE VOLTAGE


22.2A
180A 90A 55.8A

CHARGE CURRENT

Discharge time

Relationship between Self-discharge characteristic


charging voltage and temperature
110

100

90

Capacity(%)
15.6 10.4 7.8 5.2 2.6
80
15.0 10.0 7.5 5.0 2.5

14.4 9.6 7.2 4.8 2.4


70

13.8 9.2 6.9 4.6 2.3 60

13.2 8.8 6.6 4.4 2.2 50

-10 0 10 20 30 40 50 60 40
0 3 6 9 12 15 18 21 24 27 30
Ambient temperature( oC)
Storage time: months

Cycle service life in relation to


Life characteristics of Standby use
depth of discharge

50% Depth of discharge

Life(year) Number of cycles(cycles)

Temperature effects on float life Temperature effects on capacity


15

10 2.27V/Cell
Life(years)

0
10 20 30 40 50
o
Temperature( C)

THE INTERNATIONAL C ERTIFICATION N ETWORK

MH25860 G4 M19906 -92 02-E-16


ISO9001:2000

Page 2 of 2