Professional Documents
Culture Documents
CALCULATIONS
HEAT DUTY
QS (Btu/hr) = 140420
Qt (Btu/hr) = 144405.5
LMTD
R = 6.27118644 S = 0.142169
ESTIMATE LAYOUT
Uo (Btu/hrf2oF) = 6.78
NUMBER OF TUBES
Ao (f2) = 187.0135
Area of One tube (f2) = 1.570795
hi (Btu/hrf2oF) = 21.84288
As (f2) = 0.058333
hs (Btu/hrf2oF) = 198.7437
Pt = 9.15667798 Pa
0.00132843 psi
SHELL SIDE PRESSURE DROP
Ps = 1157.19465 Pa
0.16788316 psi
INPUT BOXES
HEAT EXCHANGER DESIGN CALCULATION
CALCULATIONS
HEAT DUTY
QS (Btu/hr) = 140420
Qt (Btu/hr) = 144405.5
LMTD
R = 6.271186 S = 0.142169
ESTIMATE LAYOUT
Uo (Btu/hrf2oF) = 6.78
NUMBER OF TUBES
Ao (f2) = 122.5498
Area of One tube (f2) = 1.570795
hi (Btu/hrf2oF) = 33.04436
As (f2) = 0.058333
hs (Btu/hrf2oF) = 198.7437
Pt = 20.95621 Pa
0.00304 psi
SHELL SIDE PRESSURE DROP
Ps = 1157.195 Pa
0.167883 psi