You are on page 1of 6

CONSTRUCTION OF PORT SERVICE ROAD AND

THIRD BRIDGE OVER MOHESH KHAL


CPA- 5

CONSULTANT: CONTRACTOR :
M/S, MONICO LIMITED
Maunsell Ltd. (Newzealand), In Association with H.B
Consultants Ltd. (Bangladesh).

DATA SHEET FOR SIEVE ANALISIS (Coarse Aggregate)

Name of Source : Lab. Reg. No.

Sample Location : Testing Date:

Sampling Date : Sample No. :

Description Use for : Concrete Work

Sieve Size Wt. Of Sample Percent Cum. Persent Percent Specified


Remarks
(MM) retained on each Sieve Retained Ratained Passing Rangs

gm % % % %
25.00 100

20.00 90 ~ 100

12.50 20 ~ 55

10.00 5 ~ 20

5.00 0~5

2.40 -

1.20 -

Pan

Total

(A) Original Dry Constant Wt. Of Sample = gm.


(B) Dry Constant Wt. Of Sample after Wash = gm.
% of Material Finer Than # 200 Sieve =

Contractor Consultant ME Lab.Engineer


Technician Contractor Consultant
Contractor ME Lab.Engineer
Technician Technician Contractor Consultant
M/S, MONICO LIMITED
CONSTRUCTION OF PORT SERVICE ROAD AND
THIRD BRIDGE OVER MOHESH KHAL
CPA- 5

CONSULTANT: CONTRACTOR :
M/S MONICO LIMITED
Maunsell Ltd. (Newzealand), In Association with H.B
Consultants Ltd. (Bangladesh).

BLENDING CHART OF SUB-BASE MATERIAL

Name of Source : Lab. Register No. :

Sample Location : Testing date :

Sampling Date : Sample No. :

Use for :

Sieve Percent Passing of Brick Percent Passing of Filling


Chips Sand Blending Specification
opening Remarks
Results Required
(mm)
100% 70% 100% 30%
50 100 70 100 30 100 100

38 94 65.8 100 30 95.80 85 ~ 100

20 39.27 27.489 100 30 57.49 55 ~ 95

10 15.64 10.948 100 30 40.95 35 ~ 75

5 8.79 6.153 100 30 36.15 25 ~ 60

2.40 6.77 4.739 99.96 29.988 34.73 15 ~ 50

0.600 5.28 3.696 97.64 29.292 32.99 7 ~ 35

0.300 4.09 2.863 52.84 15.852 18.72 6 ~ 27

0.075 1.5 1.05 2.58 0.774 1.82 3 ~ 15


CONSTRUCTION OF PORT SERVICE ROAD AND
THIRD BRIDGE OVER MOHESH KHAL
CPA- 5

CONSULTANT: CONTRACTOR :
M/S MONICO LIMITED
Maunsell Ltd. (Newzealand), In Association with H.B
Consultants Ltd. (Bangladesh).

BLENDING CHART OF AGGREGATE BASE TYPE - 1

Name of Source : Lab. Register No. :

Sample Location : Testing date :

Sampling Date : Sample No. :

Use for :

Sieve Percent Passing of Percent Passing of Filling


Crushed Stone Sand Blending Specification
opening Remarks
Results Required
(mm)

50 100

38 90~100

20 60~90

10 40~70

5 30~55

2.40 20~45

0.600 10~30

0.300 7~25

0.075 5~15
BLENDING CHART OF SUB-BASE MATERIAL

You might also like