Contents
Introduction pages
An independent manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 4
Four key applications: the benefit of a specialist . . . . . . . . . . . . . . . . . . . . . p. 5
Adapted solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 6
Services & Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 8
A cutting-edge laboratory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 10
For a high quality power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 11
A worldwide presence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 12
A new website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 13
Application Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 14
Fuse protection
SIDERMAT
Fuses, fuse bases FUSERBLOC combination
and fuse combination switches . . . . . . . . . . . . . . . . . . . . p. 182 p. 188 p. 230
Changeover switches
SIRCOVER and
Changeover switches, control relays COMO C SIRCOVER BY-PASS
and configuration software . . . . . . . . . . . . . . . . . . . . . . . . p. 308 p. 316 p. 328
Electronic protection
Earth leakage relays Core balance
Differential protection, voltage surge protection, RESYS M40 R WUDQVIRUPHU,&
current protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 508 p. 518 p. 522
Supervision ,QGLFDWRUVDQG
RETROFIT Line and interfaces Current transformers transducers
p. 468 p. 482 p. 488 p. 506
CORPO 308 A
The culture of independence A flexible manufacturing Responsible growth
The independence of the SOCOMEC Group structure As a Group which is open to all cultures
ensures it retains control of the decision- Backed by two European centres of and firmly committed to human values,
making process, respecting the values excellence (France and Italy), the Group also SOCOMEC promotes employee initiative
advocated by its own family shareholders and benefits from competitive production sites, and commitment. Working relationships are
shared by its employees. such as in Tunisia, and locations in the major based on the idea of partnerships and respect
With around 30 subsidiaries located on all emerging markets (India and China). for shared ethics. Through the companys
five continents, SOCOMEC has developed All sites have implemented a policy of commitment to achieving harmonious, lasting
internationally by targeting industrial and continuing development based on 'Lean development, SOCOMEC fully embraces
service applications where the quality of its management' principles; this ensures they are its responsibilities not only towards its
expertise makes all the difference. in a position to offer the quality, lead times and shareholders, employees, customers and
cost expected by our customers. partners, but also towards society as a whole
The spirit of innovation and its environment.
The focus on service SOCOMEC has been a signatory to the Global
As undisputed specialists in UPS systems, Compact since 2003.
source supply changeover, power conversion Our manufacturing expertise naturally extends
and measurement, SOCOMEC dedicates to a complete range of services designed
nearly 10% of its turnover to R&D. This means to facilitate the research, implementation
the group devotes the resources required and operation of our solutions. Our teams
to achieve its ambition: to always be at the of engineers have built their reputation on
cutting-edge of technology. reassuring closeness, specialist expertise and
a focus on customer needs.
The vision of a specialist
As a manufacturer with complete control
over its technological processes, SOCOMEC
is quite unlike the more general providers.
The Group is constantly building on its fields
of expertise in order to offer its customers
increasingly customised, better adapted
solutions.
Power Control & Safety A specialist manufacturer of electrical SOCOMEC guarantees solutions and services
equipment since 1922, SOCOMEC is the which are both relevant and efficient.
Managing power and protecting
undisputed leader in power switching and
individuals and property.
changeover solutions.
The company has always promoted the
benefits of fuses for the safety of both
individuals and equipment.
In addition, it has become a major player
in cutting-edge technology such as the
monitoring and detection of insulation defects.
Solar Power As experts in the solar energy equipment field, q ensuring the reliability of DC facilities thanks
SOCOMEC has all the specialist know-how to solutions that prevent the degradation of
Guaranteeing the safety and durability of
for implementing key strategic functions in PV insulation and electric arc failure in the DC
photovoltaic (PV) facilities.
facilities, including: current,
q safety, through specially designed load q control of very high-efficiency energy
break switches that cut the DC current conversion, via PV inverters that transform
generated by solar panels regardless of all energy generated by the solar panels into
the configuration of the installation and the power to be consumed locally or re-injected
operating conditions, into the national grid.
Energy Efficiency SOCOMEC solutions, ranging from sensors q limit reactive energy and prevent associated
to the wide choice of innovative, modular tariff penalties,
Improving building and facility energy
software packages, are driven by experts in q use the best tariffs, check supplier invoicing
efficiency.
energy efficiency. They meet the essential and accurately distribute energy bills amongst
requirements of managers or operators of consumer entities.
tertiary, industrial or local authority buildings,
and make it possible to:
q measure power consumption, identify
sources of excess consumption, and raise
occupant awareness,
In the face of increasingly SOCOMEC's support approach When you choose SOCOMEC,
important and complex energy rests on three principles: you're choosing multidisciplinary
challenges, it is vital to choose a sWKHDYDLODELOLW\RIDQ expertise in managing the
specialist partner that experienced consultant, availability, monitoring, safety and
understands fully the sWKHDELOLW\WRRIIHUDVROXWLRQWRD energy performance of low
requirements and constraints of global problem, voltage electrical installations. You
your own area of business. sWKHFUHDWLRQRIDWUXH also benefit from the
commercial partnership - a responsiveness of an
source of confidence. independent, family business
operating on a human scale.
".4-3(2$DMDQFXLDSDQR
#(1(2 LTKSHETMBSHNMLD@RTQDLDMSTMHSR
#(1(2-MDSVNQJ@M@KXRDQR
5$13$+(2$MDQFX/NVDQ,NMHSNQHMF2XRSDLRNESV@QD
Process, Oil, Gas Commercial buildings, Transport, Data centres, Healthcare buildings, Solar power, Wind
and petrochemical, Residential buildings, Telecommunications, High Rise buildings, power, Hydro-electric
Energy production, Hotel & Leisure. Public distribution, Military, Shopping centres, power
Manufacturing. Water treatment. Banking & Insurance.
R@JDXE@BSNQHMDMRTQHMFPT@KHSXB@QD
patient safety is your number 1 concern.
That's why the power supply to vital
medical equipment must never fail.
SOCOMEC recommends complete
architecture and offers a state-of-the-
art range to guarantee reliability and
productivity in healthcare buildings, in
accordance with normative requirements Green Power 2.0 STATYS
governing critical premises. UDQXGHFGDEjBHDMBX4/2 static transfer systems
".4-3(2$DMDQFXLDSDQR
#(1(2 LTKSHETMBSHNMLD@RTQDLDMSTMHSR
#(1(2-MDSVNQJ@M@KXRDQR
5$13$+(2$MDQFX/NVDQ,NMHSNQHMF2XRSDLRNESV@QD
APPLI 566 A
Specially adapted skills
Our service team consists of field personnel
Customised support
specialising in our specific domains and
experienced in the maintenance of industrial Assessment and sizing Maintenance
electrical systems. This means you benefit
Depending on your requirements, our experts A wide range of preventive or corrective
from a dual skills base:
collect and analyse all the relevant data in maintenance options designed to suit your
q technical expertise relating to the products
order to recommend the system best adapted installation and its environment, and to
that have been installed,
to your installation. ensure continuity of service of your electrical
q practical knowledge of your usage needs. networks.
Commissioning
Reassuringly close at hand Training
Installation of your equipment is carried out by
Our geographical coverage means that we are a specialist, and is totally compatible with and You will receive training, specially adapted to
close to each user and can respond quickly adapted to your use. your needs, in order to familiarise yourself with
to all requests. We can provide a complete our equipment and enable you to use it to
service from the technical diagnostics before your best advantage.
repair right up to implementation of the most
suitable solutions for your installation.
Customer-oriented service
True to our own principles, we encourage
direct and friendly contact. Our interventions
offer solutions targeted to a single problem:
Yours. Our engineers are always very attentive
to your needs, to ensure that we provide the
most relevant technical support and advice.
So you can plan your investments with SITES EN FRANCE
confidence.
CORPO 164A
For more information, please see pages
"Reactive energy power factory correction.
APPLI 540 A
CORPO 342 A
A decisive link Ongoing commitment Customised services
Located at the Companys headquarters in To adapt to the increasingly demanding These test facilities and expertise are
Benfeld, France, the Pierre Siat test laboratory standards and ever more innovative and also available to our partners who require
is one of SOCOMECs main quality pillars: its high-performance products, the Pierre Siat assistance with the qualification and
contribution to the development, qualification laboratory is constantly extending the scope of certification of their products or equipment.
and certification phases plays a decisive role its tests, investing whenever necessary in new
in the process leading to the creation of a equipment.
product or solution.
A vast range of tests
Global scale The laboratory submits all SOCOMEC
This totally independent laboratory is products and solutions (including those in
recognised by the major certification bodies enclosures) to numerous tests in the following We issue certificates
worldwide: A member of ASEFA(1) and fields: of conformity
LOVAG(2), it is accredited by COFRAC(3), UL and performance
qfunctional: component resistance and
(CTDP(4)), CSA (shared certification) and KEMA declarations upon
operating tests,
(SMT / WMT(5)). It also works in partnership request.
qdielectric: immunity to interference, dielectric
with numerous international certification insulation, overvoltage, overcurrent,
organisations(6). The quality and safety For more information, visit our web site:
qmechanical: endurance and mechanical www.socomec.fr/laboratoire-essais_fr.html
requirements specific to each country are
shocks, etc.
therefore fully taken into account.
qEnvironment: functional or electrical tests (1) Association des Stations dEssais Franaises
dAppareils lectriques basse tension (French
under extreme conditions (temperatures, salt
Specialist facilities association of low voltage electrical equipment test
spray), vibrations, etc.), stations)
With its 100 MVA (Idc 100 kA rms 1 s) short- qAC / DC endurance: in operation and under (2) Low Voltage Agreement Group
circuit platform, three 10 kA overload platforms controlled temperatures (arcs, LV / HV (3) Comit Franais dAccrditation (French accredi-
and numerous other test instruments, in outages, etc.), tation body)
facilities covering 1500 m2, the Pierre Siat (4) Client test data programme
qtemperature rise, (5) Supervised Manufacturers testing / Witnessed
laboratory is currently the 2nd largest French
qelectromagnetic compatibility (EMC), manufacturers testing
power laboratory. It combines expertise in (6) KEMA, CEBEC, UL, CSA, ASTA, Lloyds Register
electricity and mechanics, pneumatics and qmetrology,
of Shipping, Bureau Vritas, BBJ-SEP, EZU,
computing. qsafety: flammability, etc. GOST-R, etc.
Conducted during the design and production
phases, these tests guarantee the long-term
reliability of the equipment sold.
GAMME 008 W
cover a very wide range of
applications for every sector of
activity.
Key
International Sales Department
Sales, Marketing and Service
Management
1DOQDRDMS@SHUDNEjBDR
CARTE 062 A
Subsidiaries
Distributors
For your needs in Power Control & Safety and Energy Efficiency
4 100% mobility
How?
1. Download
a QR code application from your
mobile phone (QR Code Sanner Pro,
Mobiletag, ScanLife flashcode, etc.).
2. Scan
FLCD_URL_048_A_GB
4 Find answers to technical questions (FAQ)
Download section
on the Socomec
website
CORPO 286A
Download the Application Guide
Contents
FLCD_URL_010_A_GB
C
Cable clamps and cage terminals __________________________ 584
CADRYS DELTA modular_________________________________ 552
E
CADRYS enclosures _____________________________________ 551 Effective protection for your electrical installation _____________ 508
Changeover SIRCO VM1 steel enclosure ____________________ 626 Energy management _____________________________________ 406
Changeover switches SIRCO M ___________________________ 320 Enclosed changeover switches ____________________________ 622
Changeover switches standards UL and CSA ________________ 350 Enclosed fuse switches __________________________________ 604
COMBIESTER __________________________________________ 550 Enclosures & accessories _________________________________ 546
Communication accessories ______________________________ 486 Enclosures and cabinets equipped for your applications _______ 598
COMO C_______________________________________________ 316 Energy efficiency ________________________________________ 408
F M
Fuse bases _____________________________________________ 266 Management software for COUNTIS and DIRIS ______________ 464
FUSERBLOC ___________________________________________ 188 Manual motorised and automatic changeover switches ________ 312
FUSERBLOC and high speed fuses (UR) ____________________ 224 Manual Transfer Switch Equipment (MTSE) __________________ 626
FUSOMAT _____________________________________________ 238 Monitoring software and communication interfaces ___________ 406
IDE______________________________________________________44
Load break switches standards UL and CSA __________________18 PV surge protection devices ______________________________ 526
T
S Transducers ____________________________________________ 418
Transformer with integrated transducer _____________________ 504
Safety enclosures _______________________________________ 608 TVSS UL98_____________________________________________ 178
Sensor PT100 - screw type _______________________________ 505
SIDER ___________________________________________________74
SIDER polyester enclosure ________________________________ 610 U
SIDER steel enclosure____________________________________ 610
UL/CSA range (Load break switches) _________________________24
SIDERMAT _______________________________________________88
UL/CSA range (Fuse protection) ___________________________ 182
SIDERMAT combination __________________________________ 230
UL/CSA range (Changeover switches) ______________________ 308
SIRCO & SIRCO AC _______________________________________52
SIRCO DC UL98B _______________________________________ 158
SIRCO MOT PV ________________________________________ 128
SIRCO M and MV _________________________________________26
V
Voltage transformer BTV 25 _______________________________ 504
SIRCO M UL508 ________________________________________ 134
VERTELIS VISION software _______________________________ 482
SIRCO M UL98 _________________________________________ 144
SIRCO MV PV __________________________________________ 110
SIRCO polyester enclosure _______________________________ 600
SIRCO PV ______________________________________________ 116
SIRCO steel enclosure ___________________________________ 600
SIRCO UL98 ___________________________________________ 150
SIRCO VM1 ____________________________________________ 324
SIRCOVER and SIRCOVER Bypass ________________________ 328
SIRCOVER Bypass steel enclosure _________________________ 629
SIRCOVER polyester enclosure ____________________________ 625
SIRCOVER steel enclosure _______________________________ 625
SIRCOVER UL __________________________________________ 350
SURGYS D40__________________________________________ 538
SIRCO DC
UL98B SIRCO MOT PV
SN 200 to 630 A
p. 158 p. 128
p. 596
Special requests
2.".,$"@KRNL@JDR
RODBHjBNQBTRSNLHRDC
OQNCTBSR
6DVHKKGDKOXNTjMCSGD
QHFGSRNKTSHNMENQXNTQ
@OOKHB@SHNM
Please feel free to consult us.
,@BGHMDBNMSQNKONVDQCHRSQHATSHNM@MCOGNSNUNKS@HBHMRS@KK@SHNMR
switches
I
I O
O
I
O
I
O
2(1",>>$>&!
//+(>>
SIRCO
SIRCO
PV
PV
Which Which
application? function?
Load break
switches
Functions
3/4 pole load break switch
6/8 pole load break switch (1)
3/4 pole changeover switch (I-0-II) p. 328 p. 328
3/4 pole changeover switch (I-I+II-II) p. 328 p. 328
Characteristics
Operation
Manual (rotating)
Manual toggle
Trippable
Motorised p. 181 p. 181
Direct operation handle
Front
Side
External operation handle
Front
Right side
Left side
Indication of breaking
Positive break indication
Visible contacts
Switch body
Modular
(1) Please consult us.
new n ew
(1)
p. 328 p. 328
(1)
sirco-ul_022_b_1_cat
SIRCO M3, SIRCO and SIRCO V
or
These products are used as disconnecting meanswithout
Fusible Disconnect switches
restrictions ; they are heavy duty products requiring 2 inches FUSERBLOC
(50 mm) minimum of creepage distance, which gives a
maximum safety for users and installation. The short circuit
withstand of those products goes up to 200 kA.
sircom_174_a
(equivalent to CSA-C22.2 no 5) UL 508
Non fusible switches
This requirements cover Molded-case Circuit Breaker, Molded SIRCO M1 and M2
case switches and fused Molded-case switches, rated at 600
volts or less and 6 000 amperes or less.
UL508 - Industrial Control Equipment NFPA 79 Electrical Standard for industrial machinery
(equivalent to CSA-C22.2 no 14) The following types of machines are identified as industrial
These requirements cover Manual, magnetic and solidstate machinery:
Starters and Controllers, Overload relays, pushbuttons, selector
q metalworking machine tools, including machines
switches, control lights
that cut or form metal,
These products are IEC type products, smaller requiring only a
qplastics machinery,
creepage distance between phases of 1/2 inch. UL508 standard
qwood machinery, including woodworking, laminating, and
requested only 5 kA or 10 kA as short circuit withstand with
sawmill machines,
fuse protection. Their use as a disconnecting mean is therefore
limited to local disconnection of motors. These products q assembly machines,
can only be used as a disconnect mean when they have q material handling machines, including industrial robots and
been additionally tested suitable as motor disconnect. This transfer machines,
additional testing ensures that the switch as a proper closing q inspection and testing machines, including coordinate
capacity on short circuit. UL508 (switches or Circuit breakers) measuring and in-process gauging machines.
can not be used as main disconnect of a electrical panel. (i.e. in
entrance of control panels).
new
Functions
3/4 pole load break switch
6/8 pole load break switch
3/4 pole changeover switch (I-0-II)
3/4 pole changeover switch (I-I+II-II)
Characteristics
Operation
Manual (rotating)
Manual toggle
Motorised
Direct operation handle
Front
External operation handle
Front
Right side
Indication of breaking
Positive break indication
Switch body
Modular
sircm_099_a
sircm_132_a
4 pole SIRCO MV
direct operation
4 pole SIRCO M
direct operation
Strong points
Function > Total integration.
SIRCO M and MV are manually operated and Through the use of accessories,6,5&2b0 > Wide range of accessories.
modular multipolar load break switches. can be transformed into multipolar load break > Upgradeability.
They make and break under load conditions NQONKDBG@MFDNUDQRVHSBGDR
2(1".,
> Compliance to major
and provide safety isolation for any low voltage changeover switches provide on load
certifications and approvals.
circuit, particularly for machine control circuits. changeover switching between two sources
or two low voltage power circuits, as well as > Specific characteristics.
their safety isolation.
Conformity to standards
Advantages
Total integration Compliance with major certifications and > IEC 60947-3
3GD2(1".,@MC,5ETKKXHMSDFQ@SDHRNK@SHNM approvals
breaking and switching functions. 3GD2(1".,@MC,5Q@MFDNEKN@CAQD@J
6HSGHM@RHMFKDOQNCTBS2(1".,NEEDQREQNMS switches have been designed, qualified and > Other standards *
right side or left side operation. Their highly tested according to the criteria defined by available:
ETMBSHNM@KCDRHFMDM@AKDR2(1".,SNAD standards IEC 60947-3, UL508 and UL98. *See pages SIRCO UL
and CSA range
easily transformed from a load break switch This process guarantees a high quality level
to a changeover switch, offering a highly for the product which is fully adapted to
innovative modular solution for numerous arduous operating environments. Approvals and certifications(1)
applications.
General characteristics
Wide range of accessories q Double break per pole.
A single standard 3 pole load break switch q ,NTMSHMFNOSHNMR#(-Q@HKO@MDKNQ
(1) Product reference on request.
module, which can be complemented with modular panel with 45 mm front cut-out.
a choice of accessories, offers a range of q IP20 accessories.
advantages: q Severe utilisation categories Local safety enclosures
q Simplicity when choosing the device. (AC-22 and AC-23).
q Flexibility to adapt to the most varied > Fitted within a polycarbonate
applications. HQFORVXUHWKH6,5&2}0FDQ
Specific characteristics be used, for example, for
q Reduction in the cost of management and 2(1".,
storage. on-load breaking of a motor
q Positive break indication. (AC23).
q Contact point technology.
Upgradeability
q Product can be mounted directly on the
Its wide range of accessories means that door or panel side; see Door mounting kit
SGD2(1".,B@MADTOFQ@CDCDUDM@ESDQ in the accessory section.
it has been commissioned, enabling future
2(1".,5
requirements to be met.
q 5HRHAKDCNTAKDAQD@JHMFA@RDC
q Positive break indication.
sircm_029_c_2_x_cat
sircm_030_a_1_x_cat
Complete switch body for toggle operation Direct front operation with handle External operation
front, left side or right side
SIRCO MV
q 3 operations are available:
sircm_032_c_1_x_cat
sircm_034_a_2_x_cat
sircm_033_a_1_x_cat
Direct front operation External right side operation External front and left side operation
References
2(1".,
Door
External front Shaft for
Complete switch interlocked
Rating No. of External left handle external front
body with toggle Switch body Direct handle external front 4th pole
(A) poles side handle(5) for changeover and side
operation and right side
switch(5) handle(5)
handle(5)
S0 type S0 type
100 A 3P 2200 3010(1)(2)(3) I -0 I -0 2200 1010
,SXOD Black IP55 Black
1481 1111(4) IP65
Blue Black IP65 148A 5111
2299 5032 1483 1111(4)
125 A 3P 2200 3011(1)(2)(3) Red/Yellow Red/Yellow 2200 1011
IP65 IP65
(4)
1484 1111 148B 5111
2(1".,
References (continued)
2(1".,5
External Shaft for external Pre-break
No. of Switch front and right External front and side Auxiliary signal auxiliary Terminal
(4) (4)
Rating (A) poles body Direct handle side handle left side handle handle(4) contact contact shrouds
3P 2200 3110
100 A
4P 2200 4110
S0 type
I -0
S0 type S0 type
Black I -0
,ASXOD ,SXODBNMS@BS U type
3P 2200 3012 IP55 150 mm
Blue 3P
(1) 1491 0111(2) Black 1409 0615
2299 5042 -.
-" BNMS@BS-" 2294 3016(3)
IP65
125 A 2299 0001 3999 0701
Black 149A 9111 200 mm
,SXOD 4P
IP65 1409 0620
Blue -. BNMS@BS-. 2294 4016(3)
4P 2200 4012 1493 0111(2) Red/Yellow
2299 5022 2299 0011 3999 0702
IP65 320 mm
Red/Yellow 149B 9111 1409 0632
IP65
1494 0111(2)
3P 2200 3016
160 A
4P 2200 4016
(1) Standard.
(2) Defeatable handle.
(3) Top and bottom.
(4) Other handles are available. Please see accessory pages.
Accessories
Direct operation handle
SIRCO M
Rating (A) Handle colour Handle Reference
16 80 Blue ,SXOD 2299 5012(1)
acces_352_a
16 80 Red ,SXOD 2200 5013
acces_347_a
100 125 Blue ,SXOD 2200 5032(1)
,G@MCKD
(1) Standard.
,G@MCKD
SIRCO MV
Rating (A) Handle colour Handle Reference
acces_359_a
acces_344_a
100 160 Blue ,ASXOD 2299 5042(1)
100 160 Blue ,SXOD 2299 5022
(1) Standard. ,G@MCKD ,AG@MCKD
2(1".,$WSDQM@KNODQ@SHNMG@MCKD
S000 type handle
No. of Handle Defeatable
Rating (A) Type Operation External IP Reference
poles colour handle
acces_307_a_1_cat
16 80 Switch 3/4 P Front and side operation Black IP65 no 1463 5111
16 80 Switch 3/4 P Front and side operation Red/Yellow IP65 no 1464 5111
Changeover
16 80 3/4 P Front Black IP65 no 1463 5113
switches I - 0 - II
Changeover
16 80 3/4 P %QNMS Black IP65 no 1463 5114
switches I - I+II - II
S000 handle
S00 type handle
No. of Handle Defeatable
Rating (A) Type Operation External IP Reference
poles colour handle
16 80 Switch 3/4 P(1) Front and side operation Black IP55 yes 1471 1111
16 80 Switch 3/4 P(1) Front and side operation Black IP65 yes 1473 1111
16 80 Switch 3/4 P(1) Front and side operation Red/Yellow IP65 yes 1474 1111
acces_341_a_1_cat
16 80 Switch 3/4 P Left side Black IP65 no 147A 5111
16 80 Switch 3/4 P Left side Red/Yellow IP65 no 147B 5111
100 125 Switch 6/8 P Front Black IP55 yes 1471 0111
100 125 Switch 6/8 P Front Black IP65 yes 1473 0111
100 125 Switch 6/8 P Front Red/Yellow IP65 yes 1474 0111
Changeover
16 80 3/4 P Front Black IP65 yes 1473 1113
switches I - 0 - II
Changeover S00 handle
16 80 3/4 P Front Black IP65 yes 1473 1114
switches I - I+II - II
Changeover
100 125 3/4 P Front Black IP65 yes 1473 0113
switches I - 0 - II
Changeover
100 125 3/4 P Front Black IP65 yes 1473 0114
switches I - I+II - II
(1) Can also be used with 6 and 8 poles with front operation.
S0 type handle
access_343_a
Changeover
16 125 3/4 P Front Black IP65 yes 1403 2113
switches I - 0 - II
Changeover
16 125 3/4 P Front Black IP65 yes 1403 2813(1)
switches I - 0 - II
Changeover
16 125 3/4 P Front Black IP65 yes 1403 2114
switches I - I+II - II
Changeover S01 handle
16 125 3/4 P Front Black IP65 yes 1403 2814(1)
switches I - I+II - II
(1) Padlockable in 3 positions
(2) Can also be used with 6 and 8 pole devices from 16 to 40 A.
Accessories (continued)
2(1".,5$WSDQM@KNODQ@SHNMG@MCKD
S0 type handle
No. of Handle External Defeatable
Rating (A) Type Operation Reference
poles colour IP handle
Front and side
100 160 Switch 3/4 P Black IP55 yes 1491 0111
operation
acces_343_a
Front and side
100 160 Switch 3/4 P Black IP65 yes 1493 0111
operation
Front and side
100 160 Switch 3/4 P Red/Yellow IP65 yes 1494 0111
operation
100 160 Switch 3/4 P Left side Black IP65 no 149A 9111
100 160 Switch 3/4 P Left side Red/Yellow IP65 no 149B 9111
S0 handle
S1 type handle
No. of Handle External Defeatable
Rating (A) Type Operation Reference
poles colour IP handle
acces_284_a_2_cat
100 160 Switch 3/4 P Front Black IP55 yes 1411 2111
100 160 Switch 3/4 P Front Black IP65 yes 1413 2111
100 160 Switch 3/4 P Front Red/Yellow IP65 yes 1414 2111
100 160 Switch 3/4 P Right side Black IP55 no 1415 2111
100 160 Switch 3/4 P Right side Black IP65 no 1517 2111
S1 Handle
100 160 Switch 3/4 P Right side Red/Yellow IP65 no 1418 2111
100 160 Switch 3/4 P Left side Black IP65 no 141A 2111
100 160 Switch 3/4 P Left side Red/Yellow IP65 no 141B 2111
acces_346_a_1_cat
16 ... 125 S000/S00/S0 type Switch 200 mm 1407 0520
16 ... 125 S000/S00/S0 type Switch 320 mm 1407 0532
16 ... 125 S01 type Switch 200 mm 1404 0520
16 ... 125 S01 type Switch 320 mm 1404 0532
16 ... 125 S01 type Switch 400 mm 1404 0540
SIRCO M 6/8 P load break switch and 3/4 P changeover switch Use
Rating (A) Handle Type Length (mm) Reference
Standard lengths:
16 80 S00, S000 type 6/8 P and changeover switch 150 mm 1407 0515
- 150 mm,
16 80 S00, S000 type 6/8 P and changeover switch 200 mm 1407 0520
- 200 mm,
16 80 S00, S000 type 6/8 P and changeover switch 320 mm 1407 0532
- 320 mm,
100 125 S00 type 6/8 P and changeover switch 150 mm 1409 0615
- 400 mm.
100 125 S00 type 6/8 P and changeover switch 200 mm 1409 0620
Other lengths: Please consult us.
100 125 S00 type 6/8 P and changeover switch 320 mm 1409 0632
16 40 S01 type 6/8 P 200 mm 1404 0520
For 3/4 pole switches, shaft extensions are
16 40 S01 type 6/8 P 320 mm 1404 0532
for external front and side operation.
16 40 S01 type 6/8 P 400 mm 1404 0540
For 6/8 pole switches and changeover
16 80 S01 type Changeover switch 200 mm 1404 0520
switches, shaft extensions are for front
16 80 S01 type Changeover switch 320 mm 1404 0532 operation only.
16 80 S01 type Changeover switch 400 mm 1404 0540
100 125 S01 type Changeover switch 150 mm 1409 0615
100 125 S01 type Changeover switch 200 mm 1409 0620
100 125 S01 type Changeover switch 320 mm 1409 0632
For SIRCO MV
Rating (A) Handle Type Length (mm) Reference
100 ... 160 S0 type Switch 150 mm 1409 0615
100 ... 160 S0 type Switch 200 mm 1409 0620
100 ... 160 S0 type Switch 320 mm 1409 0632
100 ... 160 S1 type Switch 200 mm 1401 0620
100 ... 160 S1 type Switch 320 mm 1401 0632
100 ... 160 S1 type Switch 400 mm 1401 0640
acces_260_a_2_cat
To be ordered in
Description Handle type Reference
multiples of
Shaft guide S00 and S0 / S000 10 pieces 1419 0000
Shaft guide S01 and S1 1 piece 1429 0000
SGONKD CCHSHNM@KONKDENQ2(1".,
Use
Installation of this switched pole converts:
@ONKD2(1".,HMSN@ONKDKN@CAQD@JRVHSBG
@ONKD2(1".,HMSN@MONKDKN@CAQD@JRVHSBG
@ONKD2(1".,BG@MFDNUDQRVHSBGHMSN@ONKD
changeover switch..
Rating (A) No. of poles Type Reference
16 1P switched 2200 1000
acces_322_a
acces_323_a
acces_324_a
20 1P switched 2200 1001
25 1P switched 2200 1002
32 1P switched 2200 1003
40 1P switched 2200 1004
63 1P switched 2200 1006
80 1P switched 2200 1008 4th pole Protective -DTSQ@KONKD
100 1P switched 2200 1010 earth module
125 1P switched 2200 1011
-DTSQ@KONKD
Use
/QNUHCDR@RNKHCMDTSQ@KONKDENQ@ONKD2(1".,
N or PE
N or PE
Rating (A) No. of poles Type Reference
16 40 1P unswitched 2200 5005
sircm_078_a_1_gb_cat
63 80 1P unswitched 2200 5009
100 125 1P unswitched 2200 5011
N or PE
N or PE
Use
/QNUHCDR@OQNSDBSHUDD@QSGONKDENQ@ONKD2(1".,
Rating (A) No. of poles Type Reference
16 40 1P unswitched 2200 9005 Additional pole configuration
63 80 1P unswitched 2200 9009
100 125 1P unswitched 2200 9011
Terminal shrouds
Use
Top and bottom protection against direct contact with the terminals or connection parts.
U@HK@AKDHMNQONKDUDQRHNMRENQ2(1".,@MCHMNQONKDUDQRHNMRENQ2(1".,5
An opening on each terminal cover makes it possible to insert a temperature measurement probe.
acces_328_a
acces_329_a
For SIRCO M
Rating (A) No. of poles Position Reference
2(1".,/ 2(1".,/
16 40 1P top and bottom 2294 1005
16 40 3P top and bottom 2294 3005
63 80 1P top and bottom 2294 1009
63 80 3P top and bottom 2294 3009
100 125 1P top and bottom 2294 1011
100 125 3P top and bottom 2294 3016
For SIRCO MV
acces_327_a
Accessories (continued)
,SXOD@TWHKH@QXBNMS@BSR
Use ,@W@TWHKH@QXBNMS@BSRLNCTKDR
Pre-break and signalisation of positions 0 Pre-break is not guaranteed on the M type
@MC(AX-.
-"NQ-.@TWHKH@QXBNMS@BSR
2(1".,5
They allow to anticipate the switching of the Characteristics
main poles. They can be mounted on the -.
-"@TWHKH@QXBNMS@BSR(/VHSGEQNMS
acces_320_a
KDESNQNMSGDQHFGSRHCDNESGDCDUHBD
operation.
SIRCO M
-. -.
-"
Rating (A) Number of AC Type of AC Reference
16 125 1 AC -.
-" 2299 0001 Auxiliary contact configurations
16 125 1 AC -. 2299 0011 for SIRCO M
,@WAKNBJR,@W " Pre-break -N/QDAQD@J
SIRCO MV
Rating (A) Number of AC Type of AC Reference
100 160 1 AC -.
-" 2299 0001
100 160 1 AC -. 2299 0011
Characteristics
Operating current Ie (A)
Nominal current
Contact type 230 VAC
(A)
AC-13 AC-15
-.
-" 10 10 6
sircm_188_a_1_gb_cat
Auxiliary contact configurations for SIRCO MV
1 2 1 2
,@WHLTL4SXOD
auxiliary contacts.
sircm_098_a_1_cat
,@WHLTL,SXOD
auxiliary contact modules.
U type
sircm_048_a_1_x_cat
For SIRCO MV
Rating (A) Number of AC Type of AC Reference
100 160 1 AC -" 3999 0701
100 160 1 AC -. 3999 0702
Characteristics
Use
Operating current Ie (A)
Contact Nominal
250 VAC 400 VAC 24 VDC 48 VDC
/QDAQD@J@MCRHFM@KHR@SHNMAX-.NQ-"@TWHKH@QX
type current (A) contact.
AC-15 AC-15 DC-13 DC-13
-" 10 1.8 2.8 1.4
,@WHLTL@TWHKH@QXBNMS@BSR
.MKX@U@HK@AKDENQ
2(1".,5RVHSBGDR
-. 10 3 1.8 2.8 1.4
Conversion kit
Use
Conversion kit
This accessory enables the assembly of two 2(1".,BG@MFDNUDQRVHSBGDROQNUHCDNM for 6 or 8 pole
acces_348_a
3 pole switches (+ additional pole) in order load changeover switching between two load break
to create a: sources or two low voltage power circuits, switches
NQONKD2(1".,KN@CAQD@JRVHSBG as well as their safety isolation (I - 0 - II);
@NQONKD2(1".,BG@MFDNUDQRVHSBG
transfer without interruption of the supply is
also possible (I - I+II - II).
acces_49_a
Conversion kit
Conversion kits are supplied with a direct for changeover
front operation handle. For external operation switches I - 0 - II
the appropriate handle needs to be ordered.
Load break switches 6/8 P
Rating (A) Type Reference
16 80 6/8P switch 2269 6009
acces_350_a
acces_330_a
acces_331_a
This kit enables the direct mounting of the to install with the supplied locking nut
switch on the panel door, or on the left or mounted on the inside of the enclosure.
right side of the panel. 3 kits are available:
The connection clamps of the switch are - one for complete IP2X protection
always accessible. - one with compact design 3/4 pole
NMDHMRSDDKENQ/@MC/
For SIRCO M
Rating (A) No. of poles Description Reference
acces_332_a
16 80 3/4 P Complete IP2X protection 2299 3309
16 80 3/4 P Compact version 2299 3409
16 80 6/8 P Steel support 2299 3609
100 ... 125 3/4 P Steel support 2299 3609
6/8 pole
sircm_126_a_2_cat
side operated. 20 pieces supplied per pack.
For SIRCO M
Rating (A) Pack Reference
16 125 20 pieces 2299 9409
sircm_134_a_2_cat
operation.40 pieces supplied per pack.
For SIRCO M
Rating (A) Pack Reference
16 80 40 pieces 2299 9909
#(-Q@HKKNBJHMFBKHO
Use
3GHRKNBJHMFBKHOOQDUDMSRSGD2(1".,5EQNLRKHCHMFVGDM
#(-Q@HKLNTMSDC
For SIRCO MV
Rating (A) Type Reference
acces_337_a
5NKS@FDRDMRHMF@MCONVDQRTOOKXS@O
Use
3GHRRHMFKDONKDUNKS@FDRDMRHMFS@O@KKNVRSGDBNMMDBSHNMNEW
LL
UNKS@FDRDMRHMFNQONVDQB@AKDRSN@MX2(1".,5ONVDQSDQLHM@KVHSGNTS
reducing its connection capacity.
acces_336_a
For SIRCO MV
Rating (A) Pack Reference
100 160 2 pieces 1399 4006
5#" DC-20 A / DC-20 B 16/16 20/20 25/25 32/32 40/40 63/63 80/80 100/100 125/125
5#" DC-21 A / DC-21 B 16/16(2) 20/20(2) 25/25(2) 32/32(2) 40/40(2) 63/63(2) 80/80(2) 100/100(2) 125/125(2)
5#" DC-20 A / DC-20 B 16/16 20/20 25/25 32/32 40/40 63/63 80/80 100/100 125/125
5#" DC-21 A / DC-21 B 16/16(3) 20/20(3) 25/25(3) 32/32(3) 40/40(3) 63/63(3) 80/80(3) 100/100(3) 125/125(3)
5#" DC-20 A / DC-20 B 16/16 20/20 25/25 32/32 40/40 63/63 80/80 100/100 125/125
5#" DC-21 A / DC-21 B 16/16(4) 20/20(4) 25/25(4) 25/25(4) 25/25(4) 40/40(4) 40/40(4) 63/63(4) 63/63(4)
Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s
Rated short-time withstand current 0.3s. Icw (kA rms) 2.5 2.5 2.5 2.5 2.5 3 3 5 5
Connection
,@WHLTL"TB@AKDBQNRRRDBSHNMLL 1.5 1.5 1.5 1.5 1.5 2.5 2.5 10 10
,@WHLTL"TB@AKDBQNRRRDBSHNMLL 16 16 16 16 16 35 35 70 70
3HFGSDMHMFSNQPTDLHML@W-L 2 / 2.2 2 / 2.2 2 / 2.2 2 / 2.2 2 / 2.2 3.5 / 3.85 3.5 / 3.85 4/4.4 4/4.4
Mechanical characteristics
Durability (number of operating cycles) 100 000 100 000 100 000 100 000 100 000 100 000 100 000 100 000 100 000
.ODQ@SHMFDEENQSONKDCDUHBD-L 1 1 1 1 1 1.4 1.4 1.6 1.6
.ODQ@SHMFDEENQSONKDCDUHBD-L 1.2 1.2 1.2 1.2 1.2 1.6 1.6 2 2
Weight of a 3 pole device (kg) 0.18 0.18 0.18 0.18 0.18 0.27 0.27 0.55 0.55
Weight of a 4 pole device (kg) 0.23 0.23 0.23 0.23 0.23 0.33 0.33 0.72 0.72
Weight of a 6 pole device (kg) 0.40 0.40 0.40 0.40 0.40 0.59 0.59 1.30 1.30
Weight of a 8 pole device (kg) 0.50 0.50 0.50 0.50 0.50 0.69 0.69 1.65 1.65
Weight of a 3 pole device (kg) 0.40 0.40 0.40 0.40 0.40 0.59 0.59 1.30 1.30
Weight of a 4 pole device (kg) 0.50 0.50 0.50 0.50 0.50 0.69 0.69 1.65 1.65
(1) Category with index A = frequent operation - Category with index B = infrequent operation. (5) The power value is given for information only, the current values vary from one manufacturer
(2) one pole per polarity. to another.
(3) 3-pole device with 2 poles in series for the "+" and 1 pole for the "-". (6) For a rated operational voltage Ue = 415 VAC
(4) 4-pole device with 2 poles in series per polarity.
Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s
Rated short-time withstand current 0.3s. Icw (kA rms) 7 7 7
Connection
,@WHLTL"TB@AKDBQNRRRDBSHNMLL 10 10 10
,@WHLTL"TB@AKDBQNRRRDBSHNMLL 70 70 70
3HFGSDMHMFSNQPTDLHML@W-L 4 / 4.4 4 / 4.4 4 / 4.4
Mechanical characteristics
Durability (number of operating cycles) 50 000 50 000 50 000
.ODQ@SHMFDEENQSONKDCDUHBD-L 4 4 4
.ODQ@SHMFDEENQSONKDCDUHBD-L 4.2 4.2 4.2
Weight of a 3 pole device (kg) 0.68 0.68 0.68
Weight of a 4 pole device (kg) 0.85 0.85 0.85
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) One pole per polarity.
(3) 2 poles in series for the "+" and 1 pole for the "-".
(4) 2 poles in series per polarity.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 415 VAC.
Dimensions
2(1".,
SIRCO M 16 to 80 A
81 F 75 F
73 M 1 1
64 64 M 2
2 1
1 2
2
sircm_052_b_1_x_cat
sircm_053_b_1_x_cat
AC
AC
68
90
68
N
G
N
6 8.8 F1 T F1 8.8 6 8.8 F1 T F1 8.8
50 M5 50 M5
1. Location for: 1 switched fourth pole module (1 per device max.) or 1 unswitched 1. Location for: 1 switched fourth pole module (1 per device max.) or 1 unswitched
neutral pole or 1 protective earth module or 1 auxiliary contact. neutral pole or 1 protective earth module or 1 auxiliary contact.
2. Position for 1 auxiliary contact module only. 2. Position for 1 auxiliary contact module only.
Note: max 2 additional blocks. Note: max 2 additional blocks.
36 E
81 36 D F D 36
M
64 1
sircm_054_e_1_x_cat
50.6 J 2
1
B C 2
A
71
AC
45
68
80
N
41
25
44 8.8 F1 F1 8.8
6 T
M5
50
1. Location for: 1 switched fourth pole module (1 per device max.) or 1 unswitched A. S000 Handle
neutral pole or 1 protective earth module or 1 auxiliary contact. B. S01 Handle.
2. Position for 1 auxiliary contact only. C. S00 Handle.
Note: max 2 additional blocks.
Terminal
Overall dimensions Switch body Switch mounting Connection
Rating (A) shrouds
D min D max E min E max AC F F1 G J M N T
1640 30 235 100 372 110 45 15 68 15 30 75 15
6380 30 235 100 372 110 52.5 17.5 76 17.5 35 85 17.5
2(1".,
SIRCO M 16 to 80 A (continued)
Direct front operation for 6/8 pole load break switches External front operation for 6/8 pole load break switches or
or 3/4 pole changeover switches. 3/4 pole changeover switches.
F
J 89
F2
1 1 78 E A B C
X M 52,5
2 2
71
sircm_182_d_1_x_cat
68
45
80
N
G
45
25
6 36 44
8,8 F1 F1 8,8 43 34,7
T T 7,5
52,5
1. Location for: 1 switched fourth pole module 2. Position for 1 auxiliary contact module only. A. S000 Handle.
(1 per device max.) or 1 unswitched neutral pole or Note: max 2 additional blocks. B. S00 Handle.
1 protective earth module or 1 auxiliary contact. C. S01 Handle.
1. Location for: 1 switched fourth pole module (1 per device max.) or 1 unswitched
sircm_056_d_1_x_cat
6
8.8 F1 T F1 8.8
53
M5
A B
sircm_057_d_1_x_cat
71
AC
80
88
41
44
6
8.8 F1 T F1 8.8
53 M5
1. Location for: 1 switched fourth pole module (1 per device max.) or 2. Position for 1 auxiliary contact module only. A. S01 Handle.
1 unswitched neutral pole or 1 protective earth module or 1 auxiliary contact. Note: max 2 additional blocks. B. S0 Handle.
Dimensions (continued)
2(1".,SN /@MC/BG@MFDNUDQRVHSBG
Direct front operation for 3/4 pole changeover switches External front operation for 3 and 4 pole changeover switches
84.5
79.6
M 50 E 36
1
13.8
2
71
68
G
N
sircm_183_e_1_x_cat
F1 T 100 6
8.8
79.6
1. Location for: 1 main pole or 1 auxiliary contact (See accessories page 33 and 34).
F 2. Position for 1 auxiliary contact module only
Note: max 2 additional blocks.
2(1".,5
SIRCO MV - 100 to 160 A
Direct front operation External front operation
110 min.
2 A 2 B 357 max. C D
76 109 135 69,9 37 44
64 35 26 61 29,5
8,8 8,8
sircm_058_c_1_x_cat
124,6
131,4
71
189
88
70
6 26
53 M5 1
A. 3 poles C. S0 type handle
,@WHLTL,SXOD@TWHKH@QXBNMS@BSR
B. 4 poles D. S1 type handle
,@WHLTL4SXOD@TWHKH@QXBNMS@BSR
8,8 8,8
131,4
124,6
71
189
sircm_059_d_1_x_cat
88
70
1
6 26 2 1 2
53 M5
A. Right side operation. D. S0 type handle
,@WHLTL,SXOD@TWHKH@QXBNMS@BSR
B. 3 poles E. S1 type handle
,@WHLTL4SXOD@TWHKH@QXBNMS@BSR
C. 4 poles F. Left side operation
S000 type Right side operation With 4 xing screws With xing nut
Load break switches I I
90 90
3.2
27
22.5
45
poign_016_a_1_gb_cat
22
0 0
13.5
45 25
3.2
36
Front operation
Handle type Direction of operation Door drilling
90
90
22.5
27
45
poign_017_b_1_gb_cat
22
I II
45 25
3.2
3.2
36 13.5
S00 type Right side operation IP55 with 2 xing clips IP65 with 4 xing screws
Load break switches 40 40
I I
90 90
71 27 47
71
0 0
28
28
36
37 31
I 3
90
poign_024_a_1_gb_cat
13.5
22.5
Front operation
Handle type Direction of operation Door drilling
S00 type
IP55 with 2 xing clips IP65 with 4 xing screws With xing nut
Changeover switches 0
I-0-II and I - I+II - II or 13.5
37 37
poign_025_b_1_gb_cat
I+II 22.5
71 90
90
40
40
3
71
I II
36 27 47
28 28
9 0 90
37
78
40
poign_018_a_1_gb_cat
80
0 0
41
47
44
28
Front operation
Handle type Direction of operation Door drilling
S01 type 0
Changeover switches IP65 with 4 xing screws
or
I-0-II and I - I+II - II I+II 40
90
47
90
78
poign_019_b_1_gb_cat
I II
28
80
41
37
44
100 to 125 A
Front operation Side operation
Handle type Direction of operation Direction of operation Door drilling
S0 type Right side operation IP55 with 2 xing clips IP65 with 4 xing screws
Load break switches 40 40
I I
9 0 90
71 27 47
0 0
88
28
28
37 37 31
13.5
poign_026_a_1_gb_cat
22.5
90 90 37
78
poign_018_a_1_gb_cat
40
80
0 0
41
47
44
28
2(1".,5
100 to 160 A
S0 type Right side operation IP55 with 2 xing clips IP65 with 4 xing screws
Load break switches 40 40
I I
90 90
71 27 47
0 0
88
28
28
37 37 31
poign_026_a_1_gb_cat
13.5
0
22.5
S1 type Right side operation IP55 with 2 xing clips IP65 with 4 xing screws
Load break switches 40 40
0 I
90
90
27 47
78
I 0
28
28
70
37 31
44 Left side operation
I poign_027_a_1_gb_cat
90
> Industry.
Load break
ide_021_a_1_cat
IDE 4x40 A
ide_022_a_1_cat
Direct operation
Strong points
> Safety.
> Easy to install.
IDE 4x40 A
> Low consumption.
External operation
General characteristics
q Positive break indication.
q IP2X protection with terminal shrouds
(accessory).
q Shunt trip or undervoltage trip coil.
Advantages
Safety Easy to install
Remote tripping is especially adapted for As standard the IDE is supplied with its
protection against automatic machine restart tripping coil factory fitted and with its
after isolation and restoration of the mains connections made internally.
voltage (EN 60204.1 7.5). For IDE 125 and 160A a factory fitted auxiliary
contact is supplied as standard, simplifying
Low consumption product installation.The various fixing systems
The device coils (including undervoltage) (front or rear mount with direct or external
have a low consumption, providing increased operation) enable easy device implementation.
reliability.
ide_009_c_1_x_cat
1 1
q Available in 230 or 400 VAC versions, the IDEs can be tripped remotely via a shunt trip or undervoltage coil.
They are used to protect against automatic restarting and to prevent damage caused if the network
malfunctions and is then re-established.
N L1 L2 L3
D2 14 N L1 L2 L3
OI
OI
U >
ide_019_b_1_x_cat
N1 T1 T1 T1
ide_018_c_1_x_cat
PE T1 T2 T3 24 14
References
Base mounted
Terminal
Switch body Position covers top/
Undervoltage Switch body External operation auxiliary bottom Empty
Rating (A) No. of poles coil Shunt trip coil Direct handle 200 mm contact (2 sets) enclosure
1260 3003(1) Black IP65 Black IP65
3P 1299 5012 1299 6022 1 contact NO+NC 3/4 P
32 A 1270 3003(2) 1295 9001(5)
Red / Yellow IP65 Red / Yellow IP65 1299 5001 1299 8003
4P 1299 5013 1299 6023
1260 3004(1)(3) 1280 3004(1)(3)
3P
1270 3004(2)(3) 1290 3004(2)(3)
40 A
1260 4004(1)(3) 1280 4004(1)(3)
4P Black IP65 Black IP65
1270 4004(2)(3) 1290 4004(2)(3) 1299 6142(4) 1299 6032 1 contact NO+NC 3/4 P
1260 3007(1)(3) 1280 3007(1)(3) Red / Yellow IP65 Red / Yellow IP65 1299 0031 1299 8007
3P 1299 6143(4) 1299 6033
1270 3007(2)(3) 1290 3007(2)(3)
63 A
1260 4007(1)(3) 1280 4007(1)(3)
4P
1270 4007(2)(3) 1290 4007(2)(3)
Please consult us
1260 3013(1) 1280 3013(1)
3P
1270 3013(2) 1290 3013(2)
125 A
1260 4013(1) 1280 4013(1)
4P Black IP65 Black IP65
1270 4013(2) 1290 4013(2) 1299 5032 1299 6042 1 contact NO+NC 3/4 P
1260 3016(1) 1280 3016(1) Red / Yellow IP65 Red / Yellow IP65 1299 0021 1299 8013
3P 1299 5033 1299 6043
1270 3016(2) 1290 3016(2)
160 A
1260 4016(1) 1280 4016(1)
4P
1270 4016(2) 1290 4016(2)
(1) 230 VAC.
(2) 400 VAC.
(3) Modular device.
(4) Modular handle.
(5) This drilled pre-equipped enclosure enables immediate installation of a direct control rear
mounted IDE without auxiliary contact, with protection rating of IP65.
Door mounted
Accessories
Direct operation handle for base mounting
Rating (A) Handle colour External IP Reference
32 Black IP65 1299 5012
32 Red/Yellow IP65 1299 5013
40 63 Black IP65 1299 6142(1)
40 63 Red/Yellow IP65 1299 6143(1)
125 160 Black IP65 1299 5032
125 160 Red/Yellow IP65 1299 5033
(1) Modular handle.
ide_023_b_1_cat
Characteristics
Rating (A) Contact type Nominal current (A)
32 63 NO + NC 12
125 160 NO + NC 5
Terminal shrouds
Use
Top or bottom protection against direct contact with
terminals or connection parts.
Top and bottom pair.
Rating (A) Position Reference
32 top / bottom 1299 8003(1)
ide_035_a_1_cat
40 63 top / bottom 1299 8007(1)
125 160 top / bottom 1299 8013(1)
(1) Reference composed of 2 pieces.
Characteristics
Characteristics according to IEC 60947-3
IDE - 32 to 160 A
Thermal current Ith (40 C) 32 A 40 A 63 A 125 A 160 A
Rated insulation voltage Ui (V) 690 690 690 690 690
Uimp (kV) 6 6 6 6 6
Connection
Minimum Cu cable cross-section (mm2) 1 2.5 2.5 6 6
Maximum Cu cable cross-section (mm2) 4 10 10 70 70
Tightening torque min/max (Nm) 1.2/1.5 2/2.5 2/2.5 6/12 6/12
Mechanical characteristics
Durability (number of operating cycles) 100 000 50 000 50 000 30 000 30 000
Operating effort - 3 pole device (Nm) 0.35 0.38 0.45 1.6 2
Weight of a 3 pole device (kg) 0.26 0.35 0.39 1.35 1.45
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) The power value is given for information only, the current values vary from one manufacturer to another.
(3) For a rated operational voltage Ue = 415 VAC.
Dimensions
IDE 32 A
Direct operation with door or Direct operation with DIN-rail mounting Door interlocked external front operation
panel mounting with DIN-rail mounting
47
5
M4
4.5
58.5
72
92
ide_031_a_1_x_cat
34 55.5 67 7.3 79
4 max. 63 min. 52
106
72
4.5
34 75 91 76
1. For PE 16 mm
IDE 40 to 63 A
Direct operation with door or Direct operation with DIN-rail or Door interlocked external front operation
panel mounting back plate mounting with DIN-rail or back plate mounting
47
5 35
M4
ide_032_a_1_x_cat
100
72
76
92
83
34 68 72 18 4.3
4 max. 73 min. 76
38
96
115
144
67
ide_033_a_1_x_cat
90
80 6 min. 76
44 88 125
4 max.
sirco_456_a_1
> Network coupling.
SIRCO 3 x 250 A
direct handle
sirco_273_a_1_cat
Strong points
> Reliability and performance.
> Safety of property
and personnel.
> Simplicity.
> Easy to install.
SIRCO AC 3 x 250 A
direct handle
Enclosures
> 7KH6,5&2DQG6,5&2}$&
Function range can be easily fitted in
our enclosures and cabinets
SIRCO and SIRCO AC are manually operated multipolar load break switches. designed for electrical
They make and break under load conditions and provide safety isolation. distribution.
SIRCO are designed for 415 VAC and DC low voltage electrical circuits.
SIRCO AC are designed for heavy duty applications up to 690 VAC - AC 23.
General characteristics
q Double positive break indication given through a position indication window, located directly
on the product, and by the operating handle.
q Severe utilisation categories (AC-22 and AC-23).
q High resistance to damp heat (supplied "tropicalised").
Advantages
Reliability and performance Simplicity
The SIRCOs double breaking per pole, The standardisation of the SIRCO and
achieved through its sliding bar contact 2(1". "Q@MFDDM@AKDR@BNRSQDCTBSHNM
system, is a proven design that offers very in stock management and storage thanks to
high durability and short-circuit withstand. their shared accessories.
The quick opening and rapid closure of the
SIRCOs contacts, combined with specifically Easy to install
designed arcing chambers, provides Easy installation is facilitated thanks to:
the SIRCO AC with improved breaking
q A good centre-to-centre distance
performance.
(up to 120 mm).
q Connection up to 6x185 mm.
Safety of property and personnel
q Connection accessories which facilitate
The position indicator is located directly on connection, both flat and edgewise
the sliding bar contact mechanism, ensuring it connections.
can be seen in all circumstances.
The use of glass fibre reinforced polyester
gives the SIRCO and SIRCO AC both high
mechanical and thermal resistance.
sirco_372_b_1_cat
For ratings 2000, 2500 and 3200A, a copper bar connection kit enables the
connection between the two power terminals of one pole.
acces_223_b_2_cat
acces_220_c_2_cat
SIRCO - References
Front operation - 3 & 4 pole
Switch body Shaft for external Terminal
Rating (A) No. of poles Direct handle External handle Auxiliary contact Terminal screens
only(1) handle shrouds
3P 2600 3014 B1 type
125 A 3P 3P
4P 2600 4014 Black
2694 3014(3) 2698 3012(3)
2699 5042(2)
3P 2600 3017 4P 4P
Red
160 A 2694 4014(3) 2698 4012(3)
4P 2600 4017 2699 5043
3P 2600 3021
200 A 3P 3P
4P 2600 4021 S2 type 2694 3021(3) 2698 3020(3)
200 mm 4P 4P
3P 2600 3026 Black IP55
250 A 1400 1020 2694 4021(3) 2698 4020(3)
4P 2600 4026 1421 2111(2)
320 mm
Black IP65
3P 2600 3032 B2 type 1400 1032(2)
315 A 1423 2111
Black 500 mm
4P 2600 4032 Red IP65
2699 5052(2) 1400 1050
3P 2600 3041 1424 2111
400 A Red 3P 3P
4P 2600 4041 2699 5053 2694 3051(3) 2698 3050(3)
3P 2600 3051 4P 4P
500 A 2694 4051(3) 2698 4050(3)
4P 2600 4051
3P 2600 3064
630 A
4P 2600 4064
1st contact NO/NC
3P 2600 3081 2699 0031
800 A
4P 2600 4081 2nd contact NO/NC
2699 0032 3P
3P 2600 3099 2698 3080(3)
1000 A
4P 2600 4099 4P
200 mm 2698 4080(3)
3P 2600 3119 S4 type
CD 1250 A 1401 1520
4P 2600 4119 Black IP65
320 mm
1443 3111(2)
3P 2600 3121 1401 1532(2)
1250 A Red IP65
400 mm
4P 2600 4121 1444 3111
C2 type 1401 1540 3P
3P 2600 3161 Black 2698 3120(3)
1600 A (2)
4P 2600 4161 2799 7012 4P
Red 2698 4120(3)
3P 2600 3181 2799 7013
1800 A
4P 2600 4181
3P 2600 3200
2000 A
4P 2600 4200 V2 type
3P
3P 2600 3250 Black IP65
2698 3200(3)
2500 A 2799 7136(2) 200 mm
4P 2600 4250 4P
Red IP65 2799 3015 2698 4200(3)
3P 2600 3320 2799 7134 320 mm
3200 A
4P 2600 4320 2799 3018(2)
450 mm
3P 2600 3401 2799b
4000 A V0 type V0 type 1st/2nd contact
4P 2600 4401
Black Black IP65 NO/NC
3P 2600 3500 2799 7072(2) 2799 7155(2) included
5000 A
4P 2600 4500
(1) Device available enclosed (see "Enclosed load break switches" page 600).
(2) Standard.
(3) Top or bottom.
SIRCO AC - References
Heavy duty applications - Front operation 3 & 4 pole
Shaft for external Terminal
Rating (A) No. of poles Switch body Direct handle External handle Auxiliary contact Terminal screens
handle shrouds
3P 26AC 3020
200 A
4P 26AC 4020
3P 3P
3P 26AC 3025 2694 3021(2)(3) 2698 3020(3)
250 A
4P 26AC 4025 S2 type 4P 4P
Black 2694 4021(2)(3) 2698 4020(3)
3P 26AC 3031 J1 type IP55 200 mm
315 A Black 1421 2111(1) 1400 1020
4P 26AC 4031 1112 1111 (1)
Black 320 mm
3P 26AC 3040 J1 type IP65 1400 1032(1)
400 A Red 1423 2111 500 mm
4P 26AC 4040 1113 1111 Red 1400 1050
IP65 3P 3P
3P 26AC 3050 1424 2111 2694 3051(2)(3) 2698 3050(3)
500 A
4P 26AC 4050 4P 4P
2694 4051(2)(3) 2698 4050(3)
3P 26AC 3063
CD 630 A
4P 26AC 4063
3P 26AC 3064
630 A 1st contact NO/NC
4P 26AC 4064 2699 0031
2nd contact NO/NC
3P 26AC 3080 2699 0032
800 A 3P
4P 26AC 4080 2698 3080(2)(3)
3P 26AC 3100 S4 type 4P
200 mm
1000 A J4 type Black
1401 1520 2698 4080(2)(3)
4P 26AC 4100 Black IP65
320 mm
1142 1111(1) 1443 3111(1)
3P 26AC 3120 1401 1532(1)
Red Red
CD 1250 A 400 mm
1143 1111 IP65
4P 26AC 4120 1401 1540
1444 3111
3P 26AC 3121
1250 A 3P
4P 26AC 4121 2698 3120(2)(3)
3P 26AC 3160 4P
1600 A 2698 4120(2)(3)
4P 26AC 4160
S5 type S5 type 3P
3P 26AC 3200
Black Black IP65
(1) 200 mm 2698 3200(2)(3)
2000 A 2799 7042 1453 8111(1) 2799 3015 4P
Red Red IP65
4P 26AC 4200 320 mm 2698 4200(2)(3)
2799 7043 1454 8111 2799 3018 (1)
450 mm
3P 26AC 3400 V0 type V0 type
2799 3019 1st / 2nd 3/4P
4000 A Black Black
4P 26AC 4400 2799 7072 (1)
2799 7155 (1) included 1509 4200(4)
(1) Standard.
(2) Mandatory for voltage greater than 415 VAC.
(3) Top or bottom.
(4) Top and bottom.
SIRCO - References
Standard applications - Front operation - 6 & 8 pole
Shaft for external Terminal
Rating (A) No. of poles Switch body Direct handle External handle Auxiliary contact Terminal screens
handle shrouds
6P 2601 6013
125 A
S2 Type
8P 2601 8013 200 mm 6P 6P
B3 type Black IP55
1400 1020 2694 3014(2)(3) 1509 3012(4)
Black 1421 2111(1)
320 mm 8P 8P
4199 5012(1) Red IP65
6P 2601 6016 1400 1032(1) 2694 4014(2)(3) 1509 4012(4)
1424 2111
160 A
8P 2601 8016
6P 2601 6025 6P 6P
2694 3021(2)(3) 1509 3025(4)
250 A 8P
8P
8P 2601 8025 2694 4021(2)(3) 1509 4025(4)
C1 type S4 type
6P 2601 6040 200 mm
Black Black IP65
(1) 1401 1520
400 A 2799 7052 1443 3111(1)
320 mm
Red Red IP65 6P 6P
8P 2601 8040 1401 1532(1)
2799 7053 1444 3111 2694 3051(2)(3) 1509 3063(4)
8P 8P
6P 2601 6063 1st contact NO/NC 2694 4051(2)(3) 1509 4063(4)
2699 0061
630 A
2nd contact NO/NC
8P 2601 8063 2699 0062
6P 2601 6080
800 A
8P 2601 8080
6P 2601 6100 6P
1509 3080(4)
1000 A
C1 type 8P
8P 2601 8100 Black V1 type 1509 4080(4)
320 mm
2799 7012(1) Black IP65
2799 3018(1)
6P 2601 6120 Red 2799 7145(1)
2799 7013
1250 A
8P 2601 8120
6P 2601 6160 6P
1509 3160(4)
1600 A
8P
8P 2601 8160 1509 4160(4)
(1) Standard.
(2) Upstream or downstream at the front or rear of the device.
(3) Select 2 sets for front or rear.
(4) Upstream or downstream at the front of the device.
Accessories
Direct operation handle
SIRCO direct operation handle
No. of
Rating (A) Handle Handle colour Reference
poles
125 160 3/4 P B1 type Black 2699 5042(1)
125 160 3/4 P B1 type Red 2699 5043
125 160 6/8 P B3 type Black 4199 5012(1)
200 630 3/4 P B2 type Black 2699 5052(1)
200 630 3/4 P B2 type Red 2699 5053
acces_114_a_2_cat
acces_153_a_2_cat
acces_286_a_2_cat
250 630 6/8 P C1 type Black 2799 7052(1)
access_355_a
250 630 6/8 P C1 type Red 2799 7053
800 3200 3/4 P C2 type Black 2799 7012(1)
800 3200 3/4 P C2 type Red 2799 7013
800 1600 6/8 P C2 type Black 2799 7012(1)
800 1600 6/8 P C2 type Red 2799 7013 J1 type B2 type C2 type S5 type
4000 5000 3/4 P V0 type Black 2799 7072(1) handle handle handle handle
(1) Standard.
acces_286_a_1_cat
S5 type
Red IP65 1454 8111
4000 5000 4000 3/4 P V0 type Black IP65 2799 7155(2)(3)
(1) IP: protection degree according to IEC 60529 standard.
(2) Standard.
S3 type handle S4 type handle S5 type handle
acces_368_a_1_x_cat
135 565 500 1400 1050
135 880 750 1400 1075
165 295 200 1400 1020
165 345 250 1400 1025
315 630 400 CD 630 165 415 320 1400 1032
165 595 500 1400 1050
165 940 750 1400 1075
221 343 200 1401 1520
800 1800 630 1600 221 463 320 1401 1532
221 543 400 1401 1540
415 570 200 2799 3015
2000 3200 2000 415 690 320 2799 3018
acces_144_b_1_cat
415 820 450 2799 3019
550 680 200 2799 3015
4000 5000 4000
651 921 320 2799 3018
Accessories (continued)
Alternative S-type handle cover colours
Use
For single lever handles S1, S2, S3 type and
for double lever handle S4 type.
Other colours: Please consult us.
acces_198_a_2_cat
To be ordered
Handle colour Handle Reference
in multiples of
Light grey 50 S2, S3 type 1401 0001
Dark grey 50 S2, S3 type 1401 0011
Light grey 50 S4 type 1401 0031
S-type cover
Dark grey 50 S4 type 1401 0041
Use
Enables S-type handles to be fitted in place of older style
Socomec handles. Adapter can be utilised as a spacer to
increase the distance between the panel door and the handle
lever.
acces_187_a_1_cat
Adds 12 mm to the depth.
To be ordered
Handle colour External IP(1) Reference
in multiples of
Black 1 IP65 1493 0000
(1) IP: protection degree according to IEC 60529 standard.
acces_260_a_2_cat
Description Reference
Shaft guide 1429 0000
Auxiliary contact
Use Characteristics
Pre-break and signalling of positions 0 and I: NO/NC A/C: IP2 with front operation.
- 1 to 2 NO/NC auxiliary contacts. Connection to the control circuit
- 1 to 4 NO+NC auxiliary contacts. 6.35 mm fast-on terminal.
- 1 to 2 low level NO/NC auxiliary contacts. Electrical characteristics
30 000 operations.
acces_065_a_1_cat
NO/NC contact for 3/4 pole SIRCO and SIRCO AC
Rating (A) Position A/C Reference
125 3200 1st 2699 0031
125 3200 2nd 2699 0032
acces_076_a_1_cat
4000 5000 1st/2nd included
NO/NC low level contact for 3/4 pole SIRCO and SIRCO AC
Rating (A) Position A/C Reference
125 3200 1st 2699 0301
125 3200 2nd 2699 0302
Characteristics
Operating current Ie (A)
Current 230 VAC 400 VAC 24 VDC 48 VDC
Contact type
Rating (A) nominal (A) AC-12 AC-13/15 AC-12 AC-13/15 DC-12 DC-13 DC-14 DC-12 DC-13 DC-14
125 3200 NO/NC 16 16 4 12 3 2.5 2.5 1 2.5 1.2 0.2
125 3200 NO + NC 16 16 4 16 3 16 5 1 2.5 1.2 0.2
Inter-phase barrier
Use
Safety isolation between the terminals, essential
for use at 690 VAC or in a polluted or dusty
atmosphere.
acces_036_a_1_cat
Terminal shrouds
Use Advantage
Top or bottom protection against direct Perforations allow remote thermographic
contact with terminals or connection parts. inspection without the need to remove the
shrouds.The terminal shrouds also provide
phase separation for SIRCO and SIRCO AC
125 to 630 A.
For 3/4 poles
acces_077_a_1_cat
Rating (A) Rating (A) No. of
SIRCO SIRCO AC poles Position Reference
125 160 3P top or bottom 2694 3014(1)
125 160 4P top or bottom 2694 4014(2)
200 250 200 315 3P top or bottom 2694 3021(1)
200 250 200 315 4P top or bottom 2694 4021(2)
315 630 400 CD 630 3P top or bottom 2694 3051(1)
315 630 400 CD 630 4P top or bottom 2694 4051(2)
(1) Reference includes 3 parts for top or bottom protection.
(2) Reference includes 4 parts for top or bottom protection.
Distribution block
Use
Easy connection of several cables, downstream of the
SIRCO.
repar_020_c_2_cat
Rating No. of No of feeders per
(A) poles section (mm) Icc (kA rms)(1) Reference
160 3P 1x95 + 8x25 10 5411 3016
160 4P 1x95 + 8x25 10 5411 6016
250 3P 1x150 + 8x50 15 5411 3025
250 4P 1x150 + 8x50 15 5411 4025
400 3P 1x240 + 8x95 21 5411 3040
400 4P 1x240 + 8x95 21 5411 4040
630 3P 1x300 + 8x150 21 5411 3063
630 4P 1x300 + 8x150 21 5411 4063
Dimensions
Rating No. of
(A) poles A W E H K D R T Y
160 3P 154 286 73 46.5 261.5 36 20 4 54
160 4P 190 286 73 46.5 261.5 36 20 4 54
B
repar_003_c_1_x_cat
Terminal screens
Use
Top and bottom protection against direct contact
with terminals or connection parts.
acces_079_a_1_cat
125 160 4P top or bottom 2698 4012
200 250 200 315 3P top or bottom 2698 3020
200 250 200 315 4P top or bottom 2698 4020
315 630 400 CD 630 3P top or bottom 2698 3050
315 630 400 CD 630 4P top or bottom 2698 4050
800 CD 1250 630 CD 1250 3P top or bottom 2698 3080
800 CD 1250 630 CD 1250 4P top or bottom 2698 4080
1250 1800 1250 1600 3P top or bottom 2698 3120
1250 1800 1250 1600 4P top or bottom 2698 4120
2000 3200 2000 3P top or bottom 2698 3200
2000 3200 2000 4P top or bottom 2698 4200
4000 5000 4000 3/4 P top or bottom 1509 4200
Cage terminals
Use Material: tin-plated aluminium.
They enable a direct terminal-free connection X1
to rigid copper and aluminium conductors
with integration under the IP2X protective
cover.
X
Dimensions C
Z
born_019_a_1_x_cat
Rating (A) A A1 C E R T X X1 Z
125 160 47.5 22.5 25 12 20 3.5 8.5 M12 10
R
200 250 62 31.5 31.5 16.5 25 2.5 10.5 M16 14
315 400 71.5 32 38 9 32 5 10.5 M20 15
A1
A
500 630 76.5 37 38 9 40 5 12.5 M20 15
References
Tightening Width of
No. of Tightening
Rating (A) capacity flexible bar Reference
poles torque (Nm)
(mm) (mm)
125 160 16 95 3P 14 13 5400 3016
125 160 16 95 4P 14 13 5400 4016
200 250 16 185 3P 25 18 5400 3025
200 250 16 185 4P 25 18 5400 4025
315 400 50 240 3P 45 20 5400 3040
315 400 50 240 4P 45 20 5400 4040
500 630 70 300 3P 45 24 5400 3063
500 630 70 300 4P 45 24 5400 4063
Accessories (continued)
Copper bar connection kits
Use
To allow connection between the two power terminals of the same pole for 2000 to 3200 A
ratings (Fig. 1 and Fig 2).
For 3200 A rating, the connection pieces (part A) are delivered bridged from factory.1
Bolt sets must be ordered separately.
Further details for these specific accessories are available in the user guide downloadable from Fig. 1
www.socomec.com.
acces_220_c_1_x_cat
A
2000 2500 Bolt set - part B 1 2699 1200
3200 Connection - part A included
3200 Bolt set - part B 1 2699 1200
(1) Example for a 3 pole device equipped upstream only: Order 3 times
the indicated quantities.
Fig. 1 133.5
96.5
5
59.5
acces_224_a_1_cat
120 120 120
258
310
acces_222_b_1_x_cat
Top or bottom edgewise connection - Fig. 2 Fig.2
Quantity to order
Rating (A) Piece Reference
per pole(1) C
2000 2500 Connection - part A 1 2619 1200
2000 2 500 T piece - part C 1 2629 1200(2)
D
2000 2500 Bracket- part D 1 2639 1200(2)
3200 Connection - part A included
3200 T piece - part C 1 2629 1200 A
3200 Bracket- part D 1 2639 1200
(1) Example for a 3 pole device equipped upstream only: Order 3 times
the indicated quantities.
(2) Bolt set is provided with the accessories.
acces_225_a_1_cat
156.5
Fig.2
126.5
96.5
120 120 120 66.5
36.5
420
acces_001_a_1_x_cat
acces_005_a_1_x_cat
For SIRCO
Locking using RONIS EL11AP lock (not supplied)
Rating (A) No. of poles Operation Figure Reference
125 630 3/4 P front direct 1 2699 6008(1) Fig. 3 Fig.4
125 1800 3/4 P external front 3 1499 7701
800 3200 3/4 P front direct 2 2699 6027
1250 5000 3/4 P external front 4 2799 7002
(1) Front handle operation included.
For SIRCO AC
acces_158_a_1_x_cat
acces_004_c_1_x_cat
Locking using RONIS EL11AP lock (not supplied)
Rating (A) No. of poles Operation Figure Reference
200 CD 630 3/4 P front direct 1 2699 6011(1)
630 1600 3/4 P front direct 2 2699 6028
For SIRCO
Locking using 230 VAC undervoltage coil
(other voltages: please consult us)
Rating (A) No. of poles Operation Reference
125 630 3/4 P external front 2699 9063(1)
800 3200 3/4 P front direct 2699 9315(1)
(1) The locking system is directly mounted on the device.
q Mechanical coupling device for making switches with "n" poles of the
same or different ratings.
q Mechanical interlocking device.
bd_03_01_01
5HDFWLYHSRZHUNYDU
At 400 VAC (kvar)(5) 55 75 90 115 145 185 230 290 365
)XVHSURWHFWHGVKRUWFLUFXLWZLWKVWDQGN$UPVSURVSHFWLYH
Prospective short-circuit current (kA rms) 100 100 80 50 100 100 100 70 50
Associated fuse rating (A) 125 160 200 250 315 400 500 630 800
&LUFXLWEUHDNHUSURWHFWHGVKRUWFLUFXLWZLWKVWDQGZLWKDQ\FLUFXLWEUHDNHUWKDWHQVXUHVWULSSLQJLQOHVVWKDQVDW9$&
Rated short-time withstand current 0.3s. Icw (kA rms) 15 15 17 17 25 25 25 25 50
6KRUWFLUFXLWFDSDFLW\ZLWKRXWSURWHFWLRQ
Rated short-time withstand current 1s. Icw (kA rms) 7 7 9 9 13 13 13 13 35
Rated short-circuit making capacity without fuses Icm
11.9 11.9 15.3 15.3 26 26 26 26 73.5
(kA peak)
Connection
Maximum Cu cable cross-section (mm) 35 50 70 95 150 185 240 2 x 150 2 x 185
Minimum Cu busbar cross-section (mm) 2 x 30 x 5 2 x 40 x 5
Maximum Cu cable cross-section (mm) 50 95 95 150 240 240 240 2 x 300 2 x 300
Maximum Cu busbar width (mm) 25 25 32 32 40 40 40 50 63
Tightening torque min/max (Nm) 9/- 9/- 20/- 20/- 20/- 20/- 20/- 20/- 40/45
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 10 000 10 000 10 000 10 000 10 000 10 000 3 000
Operating effort (Nm) 6.5 6.5 10 10 10 14.5 14.5 14.5 37
Weight of a 3 pole device (kg) 1 1.5 2 2 3.5 3.5 3.5 3.5 8
Weight of a 4 pole device (kg) 1.5 1.5 2 2 4 4 4.5 4.5 10
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or phase barrier.
(3) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-".
(4) 4-pole device with 2 poles in series per polarity.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 415 VAC.
2SHUDWLRQDOSRZHULQ$&$N:(1)(5)
At 415 VAC without pre-break in AC(1) 560/560 710/710 710/710 710/710 710/710 710/710 710/710 710/710 710/710 710/710
5HDFWLYHSRZHUNYDU
At 400 VAC (kvar)(5) 460
&LUFXLWEUHDNHUSURWHFWHGVKRUWFLUFXLWZLWKVWDQGZLWKDQ\FLUFXLWEUHDNHUWKDWHQVXUHVWULSSLQJLQOHVVWKDQVDW9$&
Rated short-time withstand current 0.3s.
65 65 100 100 100 100 100 100
Icw (kA rms)
6KRUWFLUFXLWFDSDFLW\ZLWKRXWSURWHFWLRQ
Rated short-time withstand current 1s.
35 35 50 50 50 50 50 50 75 75
Icw (kA rms)
Rated short-circuit making capacity
73.5 73.5 75 75 75 80 80 80 165 165
without fuses Icm (kA peak)
Connection
Maximum Cu cable cross-section (mm) 2 x 240
Minimum Cu busbar cross-section (mm) 2 x 50 x 5 2 x 60 x 5 2 x 60 x 5 2 x 80 x 5 3 x 100 x 5 3 x 100 x 5 4 x 100 x 5 4 x 100 x 5 1 x 100 x 5 1 x 100 x 5
Maximum Cu cable cross-section (mm) 4 x 185 4 x 185 4 x 185 6 x 185 6 x 185
Maximum Cu busbar width (mm) 63 63 100 100 100 100 100 100
Tightening torque min/max (Nm) 40/45 40/45 40/45 40/45 40/45 40/45 40/- 40/- 40/- 40/-
Mechanical characteristics
Durability (number of operating cycles) 3000 3000 4000 4000 4000 3000 3000 3000 2000 2000
Operating effort (Nm) 37 37 56 56 56 75 75 75 105 105
Weight of a 3 pole device (kg) 8 8 12 12 12 22 22 22 45 45
Weight of a 4 pole device (kg) 10 10 15 15 15 25 25 25 50 50
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or phase barrier.
(3) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-".
(4) 4-pole device with 2 poles in series per polarity.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 415 VAC.
2SHUDWLRQDOSRZHULQ$&$N:(5)
At 690 VAC without pre-break AC 160 220 250 400 500 500 630
5HDFWLYHSRZHUNYDU
At 690 VAC (kvar) 160 190 250 325 400 400 450
)XVHSURWHFWHGVKRUWFLUFXLWZLWKVWDQGN$UPVSURVSHFWLYHDW9$&
Prospective short-circuit current (kA rms) 50 50 50 50 50 50 50
Associated fuse rating (A) 200 250 315 400 500 630 630
&LUFXLWEUHDNHUSURWHFWHGVKRUWFLUFXLWZLWKVWDQGZLWKDQ\FLUFXLWEUHDNHUWKDWHQVXUHVWULSSLQJLQOHVVWKDQVDW9$&
Rated short-time withstand current 0.3s. Icw (kA rms) 15 15 15 15 15 15 28
6KRUWFLUFXLWFDSDFLW\ZLWKRXWSURWHFWLRQ
Rated short-time withstand current 1s. Icw (kA rms) 8 8 8 11 11 11 20
Rated short-circuit making capacity without fuses Icm (kA peak) 22 22 22 22 22 22 40
Connection
Maximum Cu cable cross-section (mm) 70 70 70 185 240 2 x 150 2 x 185
Minimum Cu busbar cross-section (mm) 2 x 30 x 5 2 x 40 x 5
Maximum Cu cable cross-section (mm) 95 95 95 240 240 2 x 300 2 x 300
Maximum Cu busbar width (mm) 32 32 32 40 40 63 63
Tightening torque min/max (Nm) 20/- 20/- 20/- 20/- 20/- 20/- 40/45
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 10 000 5000 5000 5000 4000
Operating effort (Nm) 10 10 10 14.5 14.5 14.5 48
Weight of a 3 pole device (kg) 2 2 2 3.5 3.5 3.5 8
Weight of a 4 pole device (kg) 2 2 2 4 4 4 10
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or phase barrier.
(3) 3-pole device with 2 poles in series for the "+" and 1 pole for the "-".
(4) 4-pole device with 2 poles in series per polarity.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 690 VAC.
5HDFWLYHSRZHUNYDU
At 690 VAC (kvar) 550 750 950 950 - - -
(6)
)XVHSURWHFWHGVKRUWFLUFXLWZLWKVWDQGN$UPVSURVSHFWLYHDW9$&
Prospective short-circuit current (kA rms) 50 50 50 50 50 - -
Associated fuse rating (A) 800 800 2 x 500 1250 2 x 800 - -
&LUFXLWEUHDNHUSURWHFWHGVKRUWFLUFXLWZLWKVWDQGZLWKDQ\FLUFXLWEUHDNHUWKDWHQVXUHVWULSSLQJLQOHVVWKDQVDW9$&
Rated short-time withstand current 0.3s. Icw (kA rms) 28 55 55 53 53 53 53
Connection
Maximum Cu cable cross-section (mm) 2 x 185 2 x 240
Minimum Cu busbar cross-section (mm) 2 x 40 x 5 2 x 50 x 5 2 x 60 x 5 2 x 60 x 5 2 x 80 x 5 3 x 100 x 5 1 x 100 x 5
Maximum Cu cable cross-section (mm) 2 x 300 4 x 185 4 x 185 4 x 185 6 x 185
Maximum Cu busbar width (mm) 63 63 63 100 100 100
Tightening torque min/max (Nm) 40/45 40/45 40/45 40 40 40 40
Mechanical characteristics
Durability (number of operating cycles) 4000 4000 3000 4000 4000 3000 2000
Operating effort (Nm) 48 48 48 55 55 75 100
Weight of a 3 pole device (kg) 8 8 8 12 12 22 45
Weight of a 4 pole device (kg) 10 10 10 15 15 25 50
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or phase barrier.
(3) 3-pole device with 2 poles in series for the "+" and 1 pole for the "-".
(4) 4-pole device with 2 poles in series per polarity.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 690 VAC.
W
CA
U A
V
K
R 0
AC
BA
AA
G
N
BC
125
sirco_198_i_1_x_cat
CA
U1
90
I AD D min. 45
X1 T T T X2 H
F C 18
1. Terminal shrouds A. S2 type handle
M Z
= = Y 1
U 221 min.
V
=
= =
350
498
330
0
28
175
470
AA
210
sirco_325_d_1_x_cat
90
=
9
I 86
X1 T T T X2 140 26 60
F 166 49 61
215 14
71
1. Terminal screens A. Single lever S3 type handle
102
B. Double lever S4 type handle
C. Double lever S5 type handle
498
498
250
380
BA
sirco_448_a_1_x_cat
J T 181 71 X 71
F
15 T T T 97.5 30 (4x)
162.5
O
V
5
AB
AC
BA
AA
sirco_421_c_1_x_cat
344
X
N
P P P P P 35.5
C M L = X - 501 2 122
Overall
Rating (A) Rating (A) Switch body Switch mounting Connection
dimensions
SIRCO SIRCO AC
C F 3p. F 4p. M 3p. M 4p. N O D T V AA AB AC BA
4000 5000 4000 514 695 695 660 660 98 115.5 75 120 86 160 292 482 452
28
I 37
125
poign_010_a_1_gb_cat
47
28
24
14 14
26
45
37
.5
45
73
3.
5
20 20
28
125
37
47
28
0
poign_028_a_1_gb_cat
24
45
14 14
26
37
.5
45
73
3.
5
20 20
O 26
37
78 90 4 5.5
28
37
350
40
47
I
24
poign_011_a_1_gb_cat
20 20
26
.5
47
45
28
73
3.
5
28
60
37
210
0
47
poign_029_a_1_gb_cat
24
20 20
26
47
28
61
.5
45
73
3.
5
28
V2 Type
50
I
4 6,5
90
poign_055_a_1_gb_cat
330
50
0
31
SIRCO AC 2000 A
Front operation
Handle type Direction of operation Door drilling
S5 type
with V Escutcheon 50
I
4 6,5
90
poign_020_a_1_gb_cat
50
0
498
31
71
102
V0 type 50
0
4 6,5
poign_009_a_1_gb_cat
180
334
50
122 31
I
Connection terminal
SIRCO 125 to 630 A and SIRCO AC 200 to CD 630 A
125 160 20 25 9
V
V
4x W1 4x W1
sirco_452_b_1_x_cat
Y
V
sirco_453_b_1_x_cat
Y
V
W2 W2
X2 X1 X2 X2 X1 X2
U U
Rating (A)
SIRCO SIRCO AC U V W1 W1 X1 X2 Y
800 1000 630 1000 50 60.5 28.5 16 28.5 11 33
V1
V1
V2
V2
sirco-ac_002
X1 X1
U U
Rating (A)
SIRCO SIRCO AC U V1 V2 W X1 Y
CD 1250 A CD 1250 A 60 65 28.5 16 28.5 11
V2
X1 X1
X2 X2
X3 X3
U
Rating (A)
SIRCO SIRCO AC U V1 V2 W X1 X2 X3 Y
1250 3200 1250 1600 90 35.8 15 12.5 25 30 45 12.5
X1 X2 X3 X3 X3 X3 X2 X1
sirco_450_b_1_x_cat
5 x W
V2
V1
V3
Rating (A)
SIRCO SIRCO AC U W X1 X2 X3 V1 V2 V3
4000 5000 4000 286 13 48 35 30 86 15 15
SIDER W
$WSDQM@KEQNMSNODQ@SHNM
Strong points
SIDER_089_b_1_cat
SIDER ND W
$WSDQM@KQHFGSRHCDNODQ@SHNM
Advantages SIDER_091_b_1_x_cat
Modular product
3GDLNCTK@QCDRHFMNESGD2(#$1-#@KKNVRSGD 3
1
product to be easily adapted to suit your needs: 1. External front operation
- mixed ratings, 2. External side operation
- defining the number of poles, 3. 2x2 configurable U type auxiliary contacts for
- centring or offsetting the operating pre-break and TEST signalling
mechanism. 4. Terminal shrouds
References
Front operation
Switch body Switch body Shaft for external
Rating (A) No. of poles Direct operation External operation Direct handle External handle handle Auxiliary contact
3P 2915 3012 2921 3012
-#
4P 2915 4012 2921 4012
3P 2915 3021 2921 3020
-#
4P 2915 4021 2921 4020
1stBNMS@BS-.-"
3P 2915 3025 2921 3025 S2 type
200 mm 3999 0021(2)(3)
-# Black IP55
(1) 1400 1020 BNMS@BSR-.-"
4P 2915 4025 2921 4025 1421 2111
Black 320 mm 3999 0022(2)(3)
Black IP65
3P 2915 3031 2921 3031 3629 7901(1) 1400 1032(1) BNMS@BS-"
1423 2111
-# 500 mm 3999 0701(4)(5)
Red IP65
4P 2915 4031 2921 4031 1400 1050 BNMS@BS-.
1424 2111
3999 0702(4)(5)
3P 2915 3041 2921 3041
-#
4P 2915 4041 2921 4041
3P 2915 3051 2921 3051
-#
4P 2915 4051 2921 4051
3P 2900 3063 2900 3063
630 A
4P 2900 4063 2900 4063
3P 2900 3080 2900 3080 200 mm
800 A S4 type
Black 1401 1520 1stBNMS@BS-.-"
4P 2900 4080 2900 4080 Black IP65
2799 7012(1) 320 mm 2799 0001
1443 3111(1)
3P 2900 3120 2900 3120 Red 1401 1532(1) 2ndBNMS@BS-.-"
1DC8DKKNV(/
1250 A 2799 7013 400 mm 2799 0002
1444 3111
4P 2900 4120 2900 4120 1401 1540
2S@MC@QC
TWHKH@QXRHFM@KBNMS@BS3XOD2
%NQCHQDBSNODQ@SHNM
%NQDWSDQM@KNODQ@SHNM
TWHKH@QXRHFM@KBNMS@BS3XOD4
References (continued)
Side operation
Switch body
Switch body External right side Shaft for external
Rating (A) No. of poles Direct operation operation Direct handle External handle handle Auxiliary contact
3P 2915 3012 2921 3012
-#
4P 2915 4012 2921 4012
3P 2915 3021 2921 3020
-#
4P 2915 4021 2921 4020
1stBNMS@BS-.-"
3P 2915 3025 2921 3025 S2 type
3999 0021(2)(3)
-# Black IP55
(1) BNMS@BSR-.-"
4P 2915 4025 2921 4025 1425 2111
Black 200 mm 3999 0022(2)(3)
Black IP65
3P 2915 3031 2921 3031 3629 7901(1) 1400 1020(1) BNMS@BS-"
1427 2111
-# 3999 0701(4)(6)
1DC8DKKNV(/
4P 2915 4031 2921 4031 BNMS@BS-.
1428 2111
3999 0702(4)(6)
3P 2915 3041 2921 3041
-#
4P 2915 4041 2921 4041
3P 2915 3051 2921 3051
-#
4P 2915 4051 2921 4051
3P 2905 3063 2905 3063
630 A
4P 2905 4063 2905 4063
Black
3P 2905 3080 2905 3080 2799 7052(1)
800 A S3 type
"NMUDQRHNMJHS 1stBNMS@BS-.-"
4P 2905 4080 2905 4080 Black IP65
2799 7070(5) (1) 200 mm 2799 0011
1437 3111
3P 2905 3120 2905 3120 Red 1404 1520(1) 2ndBNMS@BS-.-"
1DC8DKKNV(/
1250 A 2799 7053 2799 0012
1438 3111
4P 2905 4120 2905 4120 "NMUDQRHNMJHS
(5)
2799 7070
3P 2905 3160 2905 3160
1600 A
4P 2905 4160 2905 4160
2S@MC@QC
TWHKH@QXRHFM@KBNMS@BS3XOD2
%NQCHQDBSNODQ@SHNM
%NQDWSDQM@KNODQ@SHNM
"NMUDQRHNMJHSMDBDRR@QXENQ@MXCHQDBSNODQ@SHNM
TWHKH@QXRHFM@KBNMS@BS3XOD4
Accessories
Direct operation handle
For front operation
Rating (A) Handle colour Reference
-#v-# Black 3629 7901
v Black 2799 7012(1)
acces_153_a_1_cat
v Red 2799 7013
2S@MC@QC
acces_148_a_1_cat
-#v-# Black 3629 7901
v Black 2799 7052
v Red 2799 7053
acces_150_a_1_cat
-#-# Black S2 type IP65 1423 2111
-#v-# Red S2 type IP65 1424 2111
v Black S4 type IP65 1443 3111(2)
acces_151_a_1_cat
v Red S4 type IP65 1444 3111
(/OQNSDBSHNMCDFQDD@BBNQCHMFSN($"RS@MC@QC
2S@MC@QC
S2 type handle
acces_152_a_1_cat
-#v-# Black S2 type IP55 1425 2111
-#v-# Red S2 type IP65 1428 2111
v Black S3 type IP65 1437 3111
v Red S3 type IP65 1438 3111
(/OQNSDBSHNMCDFQDD@BBNQCHMFSN($"RS@MC@QC
S4 type handle
Description Reference
acces_260_a_2_cat
To be ordered
Handle colour in multiples of External IP(1) Reference
Black 1 IP65 1493 0000
(/OQNSDBSHNMCDFQDD@BBNQCHMFSN($"RS@MC@QC
Accessories (continued)
Alternative S type handle cover colours
Use
For single lever handles S1, S2 and S3 .SGDQBNKNTQR/KD@RDBNMRTKSTR
types and double lever handle, S4 type.
acces_198_a_1_cat
To be ordered
Handle colour in multiples of Handle Reference
Light grey 50 Type S1, S2 14010001
Dark grey 50 Type S1, S2 1401 0011
Light grey 50 S4 type 1401 0031
Dark grey 50 S4 type 1401 0041
acces_144_b_1_cat
acces_369_a_1_cat
For front operation
Dimension X Shaft length
Rating (A) (mm) (mm) Type Reference
-#v-# v 200 mm 10 x 10 1400 1020
-#v-# v 320 mm 10 x 10 1400 1032
-#v-# v 500 mm 10 x 10 1400 1050
v v 200 mm 15 x 12 1401 1520
v v 320 mm 15 x 12 1401 1532
v v 400 mm 15 x 12 1401 1540
For side operation
acces_202_a_1_x_cat
acces_203_a_1_x_cat
Dimension Y Shaft length
Rating (A) (mm) (mm) Type Reference
-#v-# v 80 mm 10 x 10 included
-#v-# v 200 mm 10 x 10 1400 1020
v v 200 mm 15 x 12 1404 1520 X Y
and I: Characteristics
acces_056_a_1_cat
SN-.-"@TWHKH@QXBNMS@BSR -.-" "(/7
SN-.NQ-"@TWHKH@QXBNMS@BSR Electrical characteristics
SN-.
-"@TWHKH@QXBNMS@BSR
30 000 operations.
acces_047_a_2_cat
acces_056_a_1_cat
30 000 operations.
NO/NC contact
Rating (A) Position AC Reference
-#v-# 1st 3999 0021
-#v-# 2 3999 0022
v 1st 2799 0011
v 2nd 2799 0012
NC contact
Rating (A) Position AC Reference
Characteristics
-#v-# 1 to 4 3999 0701 Operating current Ie (A)
S type auxiliary contacts for signalisation - Front and right side operation
Use Electrical principle
Signalling of positions 0 and I, 3GD-.
-"2SXOD@TWHKH@QXBNMS@BSRB@M
SN-.
-"@TWHKH@QXBNMS@BSR
ADBNMEHFTQDC@R-.NQ-"
Connection to the control circuit Electrical characteristics
By terminals with a max. cross-section of 30 000 operations.
acces_051_a_2_cat
10 mm.
Terminal shrouds
Use Perforations allow remote thermographic
Top or bottom protection against direct inspection without the need to remove the
contact with terminals or connection parts. shrouds.
Advantage
Rating (A) No. of poles Position Reference
acces_093_a_1_cat
Accessories (continued)
Terminal screens
Use
Top or bottom protection against direct contact with terminals or connection parts.
acces_058_a_1_cat
Rating (A) No. of poles Position Reference
v 3P top or bottom 2998 3080
v 4P top or bottom 2998 4080
v 3P top or bottom 2998 3120
v 4P top or bottom 2998 4120
"@FDSDQLHM@KR
Use
"NMMDBSHNMNEA@QDBNOODQB@AKDRNMSNSGDSDQLHM@KRVHSGNTSKTFR
Connections
Flexible cable Rigid cable
acces_053_a_1_cat
cross-section cross-section Flexible bar Stripped
Rating (A) (mm2) (mm) width (mm) over (mm)
-# v v 13 22
-#v-# v v 18 27
-#v-# v v 20 34
-#v v v 24 34
X1
Dimensions
Rating (A) A A1 C R X X1 Z
-# 47.5 22.5 25 20 8.5 M12 10 X
-#v-# 62 31.5 31.5 25 10.5 M16 14
acces_091_a_1_x_cat
-#v-# 71.5 32 38 32 10.5 M20 15 Z
-#v 76.5 37 38 40 12.5 M20 15
Inter-phase barrier
Use
Safety isolation between the terminals,
DRRDMSH@KENQTRD@S5 "NQHM@ONKKTSDC
or dusty atmosphere.
acces_036_a_1_cat
acces_042_a_1_x_cat
acces_084_a_1_x_cat
Locking using RONIS EL11AP lock (not supplied)
Rating (A) Operation Figure Reference Fig. 1
-#v-# front direct 1 3629 7913(1)
v front direct 2 2799 7007(2) Fig.2
acces_158_a_1_x_cat
acces_157_a_1_x_cat
Rating (A) Operation Figure Reference
-#v-# external front 3 1499 7702
.SGDQRODBHEHB@BBDRRNQHDR
q Mechanical coupling device for combining switches of the same or different ratings.
q Mechanical interlocking device.
q Mechanical plates and escutcheon for standard systems.
"G@Q@BSDQHRSHBR@BBNQCHMFSN($"
-#SN-#
Thermal current Ith at 40C ND 125 A ND 200 A ND 250 A ND 315 A ND 400 A ND 500 A
Rated insulation voltage Ui (V) 800 800 800 800 800 800
Rated impulse withstand voltage Uimp (kV) 8 8 8 8 8 8
Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s
Prospective short-circuit 0.3s (kA rms) 15 15 17 17 17 17
Connection
,HMHLTL"TB@AKDBQNRRRDBSHNMLL2)
,HMHLTL"TATRA@QBQNRRRDBSHNMLL2)
,@WHLTL"TB@AKDBQNRRRDBSHNMLL2) 120 120 240 240 2 x 150 2 x 150
,@WHLTL"TATRA@QVHCSGLL 20 20 32 32 45 45
3HFGSDMHMFSNQPTDLHM-L 9 9 20 20 20 20
Mechanical characteristics
Durability (number of operating cycles)(6) 10 000 10 000 10 000 10 000 10 000 10 000
.ODQ@SHMFDEENQS-L 10 10 12 12 15 15
6DHFGSNE@ONKDCDUHBDJF 1.8 1.8 3.2 3.2 4.8 4.8
6DHFGSNE@ONKDCDUHBDJF 2.3 2.3 4.5 4.5 6.1 6.1
"@SDFNQXVHSGHMCDW EQDPTDMSNODQ@SHNM"@SDFNQXVHSGHMCDW!HMEQDPTDMSNODQ@SHNM
3GDONVDQU@KTDHRFHUDMENQHMENQL@SHNMNMKXSGDBTQQDMSU@KTDRU@QXEQNL
6HSGSDQLHM@KRGQNTCRNQOG@RDA@QQHDQ
NMDL@MTE@BSTQDQSN@MNSGDQ
ONKDCDUHBDVHSGONKDRHMRDQHDRENQSGD
@MCONKDENQSGD
%NQ@Q@SDCNODQ@SHNM@KUNKS@FD4D5 "
ONKDCDUHBDVHSGONKDRHMRDQHDRODQONK@QHSX
630 to 1600 A
Thermal current Ith at 40C 630 A 800 A 1250 A 1600 A
Rated insulation voltage Ui (V) 1000 1000 1000 1000
Rated impulse withstand voltage Uimp (kV) 12 12 12 12
Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s
Prospective short-circuit 0.3s (kA rms) 50 50 100 100
Connection
,HMHLTL"TB@AKDBQNRRRDBSHNMLL2) 2 x 150 2 x 185
,HMHLTL"TATRA@QBQNRRRDBSHNMLL2) 2 x 30 x 5 2 x 40 x 5 2 x 60 x 5 2 x 80 x 5
,@WHLTL"TB@AKDBQNRRRDBSHNMLL2) 2 x 300 2 x 300 4 x 185 6 x 240
,@WHLTL"TATRA@QVHCSGLL 63 63 100 100
3HFGSDMHMFSNQPTDLHML@W-L 20 20 20 40
Mechanical characteristics
Durability (number of operating cycles)(6) 5 000 4 000 4 000 3 000
.ODQ@SHMFDEENQS-L 45 45 45 65
6DHFGSNE@ONKDCDUHBDJF 8 8.5 11 16.5
6DHFGSNE@ONKDCDUHBDJF 9.5 10 14 20.5
"@SDFNQXVHSGHMCDW EQDPTDMSNODQ@SHNM"@SDFNQXVHSGHMCDW!HMEQDPTDMSNODQ@SHNM
3GDONVDQU@KTDHRFHUDMENQHMENQL@SHNMNMKXSGDBTQQDMSU@KTDRU@QXEQNL
6HSGSDQLHM@KRGQNTCRNQOG@RDA@QQHDQ
NMDL@MTE@BSTQDQSN@MNSGDQ
ONKDCDUHBDVHSGONKDRHMRDQHDRENQSGD
@MCONKDENQSGD
%NQ@Q@SDCNODQ@SHNM@KUNKS@FD4D5 "
ONKDCDUHBDVHSGONKDRHMRDQHDRODQONK@QHSX
Dimensions
Front operation
SIDER ND 125 to ND 500 A
Direct front operation
L 4 T T
R
2
I
70
AC
BA
AA
N
sider_059_b_1_x_cat
1. Terminal shrouds
0 Y
W
NQ-.-" "RENQOQDAQD@J@MCRHFM@KKHMF
1 Z
H T
C A
Terminal
Rating Overall dimensions shrouds Switch body Switch mounting Connection
(A) A 3p. A 4p. C AC H L N R T W Y Z AA BA
-# 160 196 178 268 82 36 130 5 36 8 3 20 162 141
-# 160 196 178 268 82 36 130 5 36 8 3 20 162 141
-# 232 322 173 350 77 31 162 6 60 10 3 20 195 165
-# 232 322 173 350 77 31 162 6 60 10 3 20 195 165
-# 280 346 173 360 77 31 172 6 66 10 3 20 214 175
-# 280 346 173 360 77 31 172 6 66 10 3 20 214 175
R
K
78
1
AC
BA
AA
N
125
sider_103_c_1_x_cat
2
45 W
K
3 20 T T
NQ-.-" "RENQOQDAQD@J@MCRHFM@KKHMF
F
2. Terminal shrouds
Front operation
SIDER 630 to 1600 A
A 160
F Z
12.5 M 70.6 Y 295 min. 60
U W 1
CA
11
V
460
220
BA
AA
80
350
0
330
sider_061_f_1_x_cat
CA
X1 T T T X2 30
90
240 14
I
1. Terminal screens
Overall
Rating dimensions Switch body Switch mounting Connection
(A) A 3p. A 4p. F 3p. F 4p. M 3p. M 4p. T U V W X1 X2 Y Z AA BA AC
630 463 543 358 438 255 335 80 40 50 13 42.5 52.5 6 106 300 260 20
800 463 543 358 438 255 335 80 50 60 47.5 47.5 6 106 320
1250 555 675 430 550 347 467 120 63 65 46.5 60.5 7 107 330
1600 555 675 430 550 347 467 120 80 80 46.5 60.5 15 111 360
Dimensions (continued)
Side operation
SIDER ND 125 to ND 500 A
External side operation
H
4 T1 T2 J 25
L
R
K
3
sider_090_d_1_x_cat
AC
BA
AA
125
2
W
45
K
Terminal
shrouds Overall dimensions Switch body Switch mounting Connection
Rating (A) AC F 3p. F 4p. H J K L N R T W AA BA T1 T2
-# 268 148 184 137 54 53 36 130 5 36 8 162 141 36 36
-# 268 148 184 137 54 53 36 130 5 36 8 162 141 36 36
-# 350 234 294 132 85 77.5 31 162 6 60 10 195 165 60 60
-# 350 234 294 132 85 77.5 31 162 6 60 10 195 165 60 60
-# 360 252 318 132 91 73 31 172 6 66 10 214 175 66 66
-# 360 252 318 132 91 73 31 172 6 66 10 214 175 66 66
SIDER 630 to 1600 A
Direct side operation External side operation
201 F
Z = M = 72
Y U W 1 2
CA
I
460
220
BA
AA
sider_065_d_1_x_cat
28
90
CA
210
11
0
30 X1 T T T X2
240 A
61
1. Terminal screen
2. Max length with shaft extension: 111 mm
S2 type
0
90
78
Right side operation
I
I 40
125
9 0
47
45
28
S3 type
78
poign_012_b_1_gb_cat
37
210
61
S4 type
37
78 0
90
40
350
poign_012_b_1_gb_cat
I
47
28
60
"NMMDBSHNMSDQLHM@K
SIDER 800 A SIDER 1250 A SIDER 1600 A
9
16 x 11 13
10 33
20 40
15
sider_073_a_1_x_cat
sider_074_a_1_x_cat
sider_075_a_1_x_cat
17 25
8.5 33 8.5 19 25 19 20 40 20
50 63 80
SIDERMATW
$WSDQM@KEQNMSNODQ@SHNM
Strong points
References
Front operation - Switch body with a shunt trip coil 230 VAC
Shaft for Auxiliary Auxiliary
Rating No. of External external contact contact Terminal Terminal Inter phase
(A) poles Switch body Direct handle handle handle position tripping shrouds screens barrier
3P 3500 3026
250 A
4P 3500 4026
3P
3P 3500 3041
3998 3040(2)
400 A
4P
4P 3500 4041 3998 4040(2)
3P 3500 3064
630 A
4P 3500 4064 S3 type
Black
1st contact
IP55
3P 3500 3081 200 mm NO/NC 3P
1431 3511(1) 1 contact
Black 1401 1520 3999 0051 3998 3063(2)
800 A NO/NC
3999 6203 320 mm 2nd contact 4P
4P 3500 4081 S3 type 3999 0031
1401 1532(1) NO/NC 3998 4063(2)
Red/Yellow
3999 0052
IP55
3P 3500 3121 1432 3511
1250 A
3P
4P 3500 4121
2998 0003
3P 4P
3P 3500 3161 2998 0004
2998 3120(2)
1600 A
4P
4P 3500 4161 2998 4120(2)
3P 3500 3180
1800 A included
4P 3500 4180
2S@MC@QC
3NOANSSNL
Side operation - Switch body with a shunt trip coil 230 VAC
Shaft for Auxiliary Auxiliary
Rating No. of External external contact contact Terminal Terminal Inter phase
(A) poles Switch body Direct handle handle handle position tripping shrouds screens barrier
3P 3505 3026
250 A
4P 3505 4026
3P
3P 3505 3041 3998 3040(2)
400 A
4P 3505 4041 4P
S3 type 3998 4040(2)
3P 3505 3064 Black
630 A 1st contact
4P 3505 4064 IP55
Black NO/NC
3P 3505 3081 1435 3511(1) 1 contact 3998 3063(2)
3999 6012(1) 200 mm 3999 0051
800 A NO/NC
4P 3505 4081 Red 1403 1520 2nd contact 3998 4063(2)
S3 type 3999 0031
3999 6013 NO/NC
3P 3505 3121 Red
1250 A 3999 0052 3P
IP55
4P 3505 4121 2998 0003
1436 3511 3P
3P 3505 3161 2998 3120(2) 4P
1600 A 2998 0004
4P 3505 4161 4P
2998 4120(2)
3P 3505 3180
1800 A included
4P 3505 4180
2S@MC@QC
3NOANSSNL
Accessories
Door interlocked external operation
For front operation
Rating (A) Handle Handle colour External IP(1) Reference
250 1800 S3 type Black IP55 1431 3511(2)
250 1800 S3 type Red/Yellow IP55 1432 3511
(/OQNSDBSHNMCDFQDD@BBNQCHMF 2S@MC@QC
SN($"RS@MC@QC
acces_166_a_2_cat
acces_151_a_2_cat
Rating (A) Handle Handle colour External IP(1) Reference
250 1800 S3 type Black IP55 1435 3511(2)
250 1800 S3 type Red IP55 1436 3511
(/OQNSDBSHNMCDFQDD@BBNQCHMF 2S@MC@QC
SN($"RS@MC@QC
S3 type handles
acces_156_a_2_cat
For external side operation
Rating (A) Handle colour Reference
250 1800 Black 3999 6012
250 1800 Red 3999 6013
acces_198_a_2_cat
For single lever S3 type handles. Other colours: Please consult us.
Colour To be ordered in multiples of Handle Reference
Light grey 50 S3 1401 0001
Dark grey 50 S3 1401 0011
- 320 mm.
For front operation
Dimension X Shaft length
Rating (A) (mm) (mm) Reference
250 630 275 439 200 mm 1401 1520
250 630 275 559 320 mm 1401 1532(1)
800 296 460 200 mm 1401 1520
800 296 580 320 mm 1401 1532(1)
1250 1800 291 455 200 mm 1401 1520
acces_203_a_1_x_cat
2S@MC@QC
acces_049_a_1_cat
Note: the shunt trip coil must not be supplied front operation: 3500 3026.
for more than 5 s. q SIDERMAT fitted with a non-standard coil
A 230 VAC shunt trip coil is fitted as 2 references: SIDERMAT 250 A,
standard to the switch body. To have 3 pole, front operation, fitted with a 110 Shunt trip coil
an alternative coil, one of the references VAC undervoltage trip coil: 3500 3026 +
opposite must be added to the switch 3991 3110.
reference.
acces_050_a_1_cat
Undervoltage trip coil
Characteristics References
Shunt trip coil Replacement Alternative
Alternating voltage (V) Shunt trip coil tripping coil factory fitted coil
24 48 110 230 400
(+5% to -20%)(1) Voltage Reference Reference
Consumption on inrush (VA) 80 100 100 120 120 24 VAC 3990 1024 3991 1024(1)
Direct voltage (V)
12 24 48 110 220 48 VAC 3990 1048 3991 1048(1)
(+5% to -20%)
110 VAC 3990 1110 3991 1110(1)
Consumption on inrush (W) 80 100 100 120 120
230 VAC 3990 1220 included
-NSD3GDRGTMSSQHOBNHK5 "LTRSMNSADRTOOKHDCENQLNQDSG@MR
400 VAC 3990 1380 3991 1380(1)
RGTMSSQHOBNHKHRRTHSDCENQSGDRS@MC@QCCDUHBD
12 VDC 3991 2012(1)
24 VDC 3990 2024 3991 2024(1)
48 VDC 3990 2048 3991 2048(1)
Undervoltage AC trip coil
110 VDC 3990 2220 3991 2220(1)
Alternating voltage (V)
(+5% to -10%)
24 48 110 230 400 220 VDC
3NADNQCDQDC@SSGDR@LDSHLD@RSGDRVHSBG
3991 2220(1)
Permanent consumption (VA) 13 13 13 13 20
Consumption on inrush (VA) 13 13 13 13 20 Undervoltage trip coil
Minimum maintaining voltage (V) 15 25 60 140 200 Replacement Alternative
tripping coil factory fitted coil
Voltage Reference Reference
Undervoltage DC trip coil
24 VAC 3990 3024 3991 3024(1)
Direct voltage (V)
12 24 48 110 220 48 VAC 3990 3048 3991 3048(1)
(+5% to -10%)
Permanent consumption (W) 13 13 13 13 13 110 VAC 3990 3110 3991 3110(1)
Consumption on inrush (W) 13 13 13 13 13 230 VAC 3990 3220 3991 3220(1)
Minimum maintaining voltage (V) 6 15 25 60 140 400 VAC 3990 3380 3991 3380(1)
12 VDC 3990 4012 3991 4012(1)
Delayed undervoltage trip coil 24 VDC 3990 4024 3991 4024(1)
Voltage Time (ms) Reference 48 VDC 3990 4048 3991 4048(1)
230 VAC 430 3993 3230(1) 110 VDC 3990 4110 3991 4110(1)
400 VAC 410 3993 3400(1) 220 VDC 3990 4220 3991 4220(1)
3NADNQCDQDC@SSGDR@LDSHLD@RSGDRVHSBG
3NADNQCDQDC@SSGDR@LDSHLD@RSGDRVHSBG
Accessories (continued)
Auxiliary contact
Use Characteristics
Pre-break and signalling of positions 0 and I: NO/NC auxiliary contact: IP2X.
1 to 2 NO/NC auxiliary contacts. Electrical characteristics:
Coil tripping 30 000 operations.
1 to 2 NO/NC auxiliary contacts.
Connection to the control circuit
By 6.35 mm fast-on terminal.
acces_048_a_1_cat
Characteristics References
NO/NC position contact NO/NC position contact
Operating current Ie (A) Rating (A) Position AC Reference
Current 250 VAC 400 VAC 24 VDC 48 VDC 250 1800 1st 3999 0051
Rating (A) nominal (A) AC-13 AC-13 DC-13 DC-13 250 1800 2nd 3999 0052
250 1800 16 12 8 14 6
NO/NC low level position contact
Rating (A) Position AC Reference
250 1800 1st 3999 0111
NO/NC changeover contact, signalling coil tripping
250 1800 2nd 3999 0112
Operating current Ie (A)
Current 250 VAC 400 VAC 24 VDC 48 VDC NO/NC contact signalling coil tripping
Rating (A) nominal (A) AC-13 AC-13 DC-13 DC-13 Rating (A) Position AC Reference
250 1800 16 12 8 12 2 250 1800 1 3999 0031
Terminal shrouds
Use Perforations allow remote thermographic
Top or bottom protection against direct inspection without the need to remove the
contact with terminals or connection parts. shrouds.
Advantage
acces_212_a_2_cat
250 630 4P top or bottom 3998 4040
800 3P top or bottom 3998 3063
800 4P top or bottom 3998 4063
Terminal screens
Use
Top or bottom protection against direct
contact with terminals or connection parts.
Inter-phase barrier
Use
Safety isolation between the terminals, essential for use at 690 VAC or in
a polluted or dusty atmosphere.
Rating (A) No. of poles Reference
acces_036_a_2_cat
acces_010_b_1_x_cat
- using a padlock (not supplied) and factory handle,
integrated into the handle. Padlocking, in - locking using RONIS EL11AP lock
external front operation, locks the door. (not supplied).
Locking using RONIS EL11AP lock (not supplied) Lock RONIS 1104A
Rating (A) Operation Reference
250 630 direct 3999 6107
800 1800 direct 3999 7007
Cage terminals
Use
Connection of bare copper cables onto the terminals (without lugs).
Connections
Flexible cable Rigid cable
cross-section cross-section Flexible bar Stripped
Rating (A) (mm2) (mm) width (mm) over (mm)
acces_053_a_2_cat
250 16 185 16 185 18 27
400 50 240 50 300 20 34
630 70 300 70 300 24 34
Dimensions
Rating X1
(A) A A1 C R X X1 Z
acces_091_a_1_x_cat
250 62 31.5 31.5 25 10.5 M16 14
X
400 71.5 32 38 32 10.5 M20 15
Z
630 76.5 37 38 40 12.5 M20 15
References
Rating (A) No. of poles Reference A1
Connection
Minimum Cu cable cross-section (mm2) 95 185 2 x 150 2 x 185 4 x 240
Minimum Cu busbar cross-section (mm2) 2 x 30 x 5 2 x 40 x 5 2 x 60 x 5 2 x 80 x 5
Maximum Cu cable cross-section (mm2) 240 240 2 x 300 2 x 300 4 x 185 6 x 240 8 x 240
Maximum Cu busbar width (mm) 40 40 50 63 100 100 100
Tightening torque min (Nm) 20 40 40 20 40 40
Mechanical characteristics
Durability (number of operating cycles) 8000 8000 5000 5000 5000 3000 3000
Weight of a 3 pole device (kg) 6.5 7 8 11 14 19 21
Weight of a 4 pole device (kg) 7.5 8 9.5 13 16 21.5 23.5
"@SDFNQXVHSGHMCDW EQDPTDMSNODQ@SHNM"@SDFNQXVHSGHMCDW!HMEQDPTDMSNODQ@SHNM
6HSGSDQLHM@KRGQNTCRNQOG@RDA@QQHDQ
/NKDRB@MMNSADITWS@ONRDC
ONKDCDUHBDVHSGONKDRHMRDQHDRODQONK@QHSX
3GDONVDQU@KTDHRFHUDMENQHMENQL@SHNMNMKXSGDBTQQDMSU@KTDRU@QXEQNLNMDL@MTE@BSTQDQSN@MNSGDQ
%NQ@Q@SDCNODQ@SHNM@KUNKS@FD4D5 "
V1
K1
AC
N
AA
sdmat_061_b_1_x_cat
190
V2
210
X T H
2
J C
E min. 61
1. Terminal shrouds 2. Reset fuse 70
Terminal
Overall dimensions shrouds Switch body Switch mounting Connection
A A E F F J J P P X X
Rating (A) 3p. 4p. W C min AC 3p. 4p. H 3p. 4p. K1 M N 3p. 4p. R T U V1 V2 W 3p. 4p. Y Z AA
250 435 495 309 248 275 388 285 345 148 253 313 115 210 180 10 70 7 65 32 35 43 11 31 46 3 67 238
400 435 495 309 248 275 388 285 345 148 253 313 115 210 180 10 70 7 65 32 35 43 13 31 46 5 69 238
630 435 495 318.5 248 275 388 285 345 148 253 313 115 210 180 10 70 7 65 32 35 43 13 31 46 8 72 257
800 491 570 350 262 296 470 346 426 178 308 388 160 250 250 20 100 9 80 50 60 60 15 36 65 7 72 320
A
F 160
16 M Z
250
U Y 2
9
V
AC
AA
250
B
190
210
sdmat_062_b_1_x_cat
1
59 120
J 256,5
E min. 61
1. Reset fuse 70
2. Terminal screens
Terminal
Overall dimensions shrouds Switch body Switch mounting Connection
Rating (A) A 3p. A 4p. W E min AC F 3p. F 4p. J 3p. J 4p. M 3p. M 4p. U V Y Z AA
1250 582 702 355 291 480 437 557 400 520 345 465 63 65 7 106 330
1600 582 702 370 291 479 437 557 400 520 345 465 80 80 15 110 360
1800 582 702 370 291 479 437 557 400 520 345 465 100 80 15 110 360
W
V1
K1
R
190
372,5
AC
N
AA
sdmat_036_c_1_x_cat
V2
210
Y
H X T
1 A
279,5
D 61
1. Reset fuse 70
2. Terminal shrouds
Terminal
Overall dimensions shrouds Switch body Switch mounting Connection
P P X X
Rating (A) A 3p. A 4p. D 3p. D 4p. AC F 3p. F 4p. H K1 M N 3p. 4p. R T U V1 V2 W 3p. 4p. Y Z AA
250 365 425 357 417 388 285 345 148 115 210 180 10 70 7 65 32 35 43 11 31 46 3 67 238
400 365 425 357 417 388 285 345 148 115 210 180 10 70 7 65 32 35 43 13 31 46 5 69 238
630 365 425 357 417 388 285 345 148 129 210 180 10 70 7 65 45 49 49 13 31 46 8 72 257
800 421 501 413 493 470 346 426 178 160 250 250 20 100 9 80 50 60 60 15 36 65 7 72 320
160 F
Z 16 M
sdmat_037_d_1_x_cat
250
U R 9 2
90
190
372,5
250
AC
AA
==
V
70
210
Y
1 43 120 120 120 62
279,5 A
D 61
1. Reset fuse 70
2. Terminal screens
Terminal
Overall dimensions shrouds Switch body Switch mounting Connection
Rating (A) A 3p. A 4p. D 3p. D 4p. AC F 3p. F 4p. M 3p. M 4p. U V Y Z AA
1250 522 641 504 624 480 437 557 345 465 63 65 7 106 330
1600 522 641 504 624 479 437 557 345 465 80 80 15 110 360
1800 522 641 504 624 479 437 557 345 465 100 80 15 110 360
S3 type 20 20 I
0
78
RESET 70 90
47 90 37
47
1414
20 20
I
0
sdmat_075_a_1_gb_cat
210
70
37
1414
61 RESET
Connection terminal
SIDERMAT 800 A SIDERMAT 1250 A SIDERMAT 1600 A SIDERMAT 1800 A
19x11 15 16 x 11 13 13
sdmat_057_a_1_x_cat
sdmat_045_a_1_x_cat
sdmat_044_a_1_x_cat
sdmat_043_a_1_x_cat
20 40
20 40
30
33
17 25
10
30 19 25 19 20 40 20 25 50 25
33 63 80 100
50
> Buildings.
switches
sirco-mc_003_a_1_cat
sirco-mc_002_a_1_cat
Strong points
> Compact.
> High breaking capacity
up to 1000 VDC.
> Safety.
> Easy assembling.
SIRCO MC PV 25 A - 1000 VDC SIRCO MC PV 25 A - 1000 VDC
DIN rail mounting Door mounting
Check it out!
> Need an enclosed switch?
No problem with our specific
Function product department. We
have solutions for any
SIRCO MC PV are DC load break switches. They make and break under load conditions and requirement.
provide optimum safety isolation for any PV circuit.
Advantages
Compact Safety
Thanks to its compact design, the limitation q Pre-bridging is factory-achieved for easier,
coff_380_a_1_cat
of space within the combiner box or the solar quicker and safer connection.
inverter is greatly reduced. q Direct access to connection terminals for
adequate tightening.
High breaking capacity up to 1000 VDC.
q Making and breaking capacity under load Easy mounting
conditions up to 1000 VDC. Three mounting possibilities are available for Conformity to standards
q Specific photovoltaic test beyond optimum integration and time saving:
QDPTHQDLDMSRAXRS@MC@QC($"
q DIN rail or back plate mounting. > IEC 60947-3
q Door mounting. > UL508i(1)
q Quick Fix mounting to save time when
integrating into solar inverters.
SIRCO MC PV SIRCO MC PV
DIN-rail mounting Door mounting
Multi-circuit breaking
q The SIRCO MC PV for double circuits (2 MPPT: Maximum Power Point Tracking) enables connection of two independent photovoltaic panel strings
to a single switch in order to reduce the costs of the global solution.
Inverter 1 Inverter 2
+ - + -
7 1 5 7
sirco-mc_024_a_1_x_cat
sirco-mc_045_a_1_gb_cat
RHQBNLB>>@
8 2 6 8
+ - + -
Panel 1 Panel 2
Inverter
- +
1 3 5
sirco-mc_025_a_1_x_cat
sirco-mc_013_b_1_gb_cat
AC AC
sirco-mc_020_a
2 4 6
- Panel
+
References
2(1".,"/55#"#(-Q@HKNQA@BJOK@SDLNTMSHMF
Number of poles No of poles Direct External Shaft for Auxiliary
Rating (A) Circuit type by PV polarity(3) AC current Switch body handle(1) handle external handle contact
MC0 type
30 A PV + AC circuit 1 P+, 1P- 2P 21PV 2162 Blue
MC1 type
2119 0012(2) Black
Double PV circuit 2 x (1P+, 1P-) - 21PV 5102 (/
Blue MC01 1 contact
2119 3312(2) vLL
type NC+NO
Single PV circuit 2 P+, 1 P- - 21PV 3124 2107 0516
2119 1012 2119 0001
Red / Yellow
(/
PV + AC circuit 2 P+, 1 P- 2P 21PV 3184
40 A 2119 3313
Blue MC01
Double PV circuit 2 x (1P+, 1P-) - 21PV 6124 type
2119 1412
Shaft for
Number of poles No of poles Direct External external Auxiliary
Rating (A) Circuit type by PV polarity(3) AC current Switch body handle(1) handle handle contact
Blue MC0
type
2119 0012(2)
Single PV circuit 2 P+, 1 P- 21PV 3722
Blue MC01
25 A type
2119 1012
2(1".,"/55#"#NNQLNTMSHMF
External
Number of poles No of poles External handle Switch body handle Auxiliary
Rating (A) Circuit type by PV polarity(1) AC current Switch body "switch body" "Quick Fix" "Quick Fix" contact
40 A Red/Yellow
(/
PV + AC circuit 2 P+, 1 P- 2P 21PV 3284 21PV 3384 2139 3313
Red/Yellow
(/
40 A Single PV circuit 2 P+, 1 P- 21PV 4854 21PV 4954 2139 3313
Accessories
Direct operation handle
Use
The direct operation conversion kit requires an additional
LLCHRS@MBDNMD@BGRHCDNESGD@MCONKDCDUHBD
Handle 45 mm modular
Rating (A) colour Type of locking Handle DIN front plate Reference
acces_305_a_1_cat
v Blue - MC0 type yes 2119 0012(1)
O@CKNBJ
v Blue MC01 type yes 2119 1012
mm
(1) Standard handle.
MC0 handle
2 MPPT 600 V
Handle 45 mm modular
Rating (A) colour Type of locking Handle DIN front plate Reference
30 Blue - MC0 type yes 2119 0012
@BBDR>>@>>B@S
O@CKNBJ
30 Blue MC01 type yes 2119 1012
mm
O@CKNBJ
40 Blue MC01 type yes 2119 1412
mm
2 MPPT 1000 V
Handle 45 mm modular MC01 handle
Rating (A) colour Type of locking Handle DIN front plate Reference
O@CKNBJ
25 Blue MC01 type yes 2119 1412
mm
Use
The external control will force the operator user-friendly and adapted to meet
@BBDR>>@>>B@S
to safely disconnect and isolate the solar requirements of residential installations,
cell strings prior to any intervention. large roofs and ground-based generators.
External controls are
Door mounting
Rating (A) Handle Handle colour Type of locking External IP(1) Reference MC4 handle
(2)
v MC2 type Blue - IP55 2129 0112
@BBDR>>@>>B@S
@BBDR>>@>>B@S
MC1 and S000 shafts can be adjusted and MC1 type:
cut depending on the need. q LL@ITRS@AKDTOSNLL
S000 type:
q 150 mm S000 type shaft
q 200 mm
acces_308_a_1_x_cat
q 320 mm
DIN rail or back plate mounting
Rating (A) Handle Dimension X (mm) Length (mm) Reference
v MC1 type v 2107 0516
v S000 type v 150 2107 0515
v S000 type v 200 2107 0520 X
v S000 type v 320 2107 0532
Terminal shrouds
Use For SIRCO MC PV
Top or bottom protection against direct contact Rating (A) Type of mounting No. of poles Position Reference
with the terminals or connection parts. 1 and 3 v rail / door mounting 1P top or bottom 2194 1004
poles are available. v rail / door mounting 3P top or bottom 2194 3004
The SIRCO MC PV load break switch is pre-
bridged. Terminal covers are mounted on the
top or bottom free space of the device.
Possibility to assemble a terminal shroud on the + - - - - -
bridge side by removing the insulating material
sirco-mc_011_d_1_cat
of the series connection bar (irreversible step). + - - + + + + - - + + + + -
@BBDR>>@>>B@S
+ - - + + -
Terminal shrouds 3 pole
Accessories (continued)
Auxiliary contact
Use Rating (A) Type of mounting Contact(s) Contact type Reference
These auxiliary contacts signalling position 0 and 1 can be normally DIN-rail / back plate
v 1 contact NO + NC 2119 0001
open or normally closed contacts. They can be fixed on the left or mounted
right side of the switch body and/or on the power additional pole. v Door mounted 1 contact NO + NC 2129 0001
Connections
Min./max cross-sections: 1 mm/4 mm Characteristics according to IEC 60947-5-1
3HFGSDMHMFSNQPTD
-L Operating current Ie (A)
230 VAC 400 VAC 690 VAC
Contact
Rating (A) type Thermal current Ith (A) AC-15 AC-15 AC-15
v NO + NC 4 2
sirco-mc_012_a_1_cat
"G@Q@BSDQHRSHBR@BBNQCHMFSN($"
25 to 40 A
Thermal current Ith at 40C(1) 25 A 30 A 40 A
Rated insulation voltage Ui (V) 1000 1000 1000
Rated impulse withstand voltage Uimp (kV) 8 8 8
Connection
Minimum Cu cable cross-section 1.5 1.5 1.5
Maximum Cu cable cross-section (mm2) 10 10 10
Tightening torque mini / maxi (Nm) 1.2 1.2 1.2
Mechanical characteristics
Durability (number of operating cycles) 30 000 30 000 30 000
Operating effort (Nm) 0.8 0.8 0.8
Weight of 2 pole PV device (kg) 0.110 0.110 -
Weight of a 3 pole PV device (kg) 0.125 0.125 0.125
Weight of 2 a pole PV and 2 pole AC device (kg) 0.180 0.180 -
Weight of a 3 pole PV and 2 pole AC device (kg) - -
Weight of a 4 pole PV device (kg) - -
Weight of a 4 pole PV device, 2 double PV circuit (kg) 0.145 0.145 -
6DHFGSNE@ONKD/5CDUHBDCNTAKD/5BHQBTHSJF - - 0.250
(1) For other temperatures: Please consult us.
Dimensions
DIN rail mounting - Direct operation
73.5 91.5 91.5
52 42 42
5 5
3.8 A B
sirco-mc_004_b_1_x_cat
70
65
60
3 4 5 3 78
4
2 1
48.5 48.5
25 67.5 67.5
3.8
sirco-mc_005_b_1_x_cat
3 4 5 3 66
70
65
60
78
2 1
25 55 32
Door mounting
44.5 51 34
1 2
RHQBNLB>>A>>W>B@S
3 4 5 3
55
5. AC or PV power pole.
A. MC2 handle.
max. 5
37
Dimensions
"Quick Fix" door mounting
60 36 60 35
44.5 50 50
1 2
A B
RHQBNLB>>A>>W>B@S
3 4 5 3
55
55
17
37
1. Terminal shrouds 1P. 4. AC power pole. A. MC3 handle
2. Terminal shrouds 3P. 5. AC or PV power pole. B. MC4 handle
3. Auxiliary contact.
3.8 A
RHQBNLB>>@>>W>B@S
70
65
60
78
2 2
4.65
1 1
48
25 71
3.8
RHQBNLB>>@>>W>B@S
66
70
65
60
78
2 2
1 1
25 66.5 32
MC1 type I
32 90 4.5
14
66
0
OFF 0
0 OFF
33
66
36
S000 type I
90
3
27
ONHFM>>@>>FA>B@S
13
45
45 25 36 3.2
Door mounting
Front operation
Handle type Direction of operation Door drilling
MC2 type I
90
16.5
37
39 10 24 12.5
MC3 type
Quick Fix I
90 3.2
22.5
12.5
48
48 36
55 56
MC4 type
Quick Fix
I
32 90 3.2
22.5
12.5
ONHFM>>@>>FA>B@S
0
66
0
OFF 0 OFF
33
66
Poles connections
Switching of polarities + and -
Single PV circuit PV and AC circuit Double PV circuit
RHQBNLB>>@>>W>B@S
sirco-mc_025_a_1_x_cat
sirco-mc_024_a_1_x_cat
Direct operation
Rating Single PV circuit PV and AC circuit Double PV circuit
5#" 21PV 2102 21PV 2162 21PV 5102
Inverter Inverter Inverter 1 Inverter 2
- + - + + - + -
1 5 1 3 5 7 1 5 7
AC AC
sirco-mc_044_a_1_gb_cat
sirco-mc_013_a_1_gb_cat
sirco-mc_045_a_1_gb_cat
2 6 2 4 6 8 2 6 8
- + - + + - + -
Panel Panel Panel 1 Panel 2
1 3 5
1 3 5
RHQBNLB>>@>>FA>B@S
RHQBNLB>>@>>FA>B@S
RHQBNLB>>@>>FA>B@S
AC AC 2 4 6 2 4 6
2 4 6
2 4 6 - + + - + +
Inverter 1
Inverter 2
Panel 1
Panel 1
Panel 2
Panel 2
- + +
- + + Panel Inverter Panel
Panel Inverter Panel
1 3 5 7
sirco-mc_048_a_1_gb_cat
2 4 6 8
- - + +
Inverter
Inverter
Panel
Panel
RHQBNLB>>@>>W>B@S
sirco-mc_024_a_1_x_cat
sirco-mc_025_a_1_x_cat
Door mounting
Rating Single PV circuit PV and AC circuit Double PV circuit
5#" 21PV 2202 21PV 2262 21PV 5202
21PV 2302 21PV 2362 21PV 5302
Inverter 1 Inverter 2
Inverter Inverter - + - +
+ - + -
RHQBNLB>>@>>FA>B@S
sirco-mc_008_a_1_gb_cat
sirco-mc_050_a_1_gb_cat
7 1 5 7
1 5 1 3 5
AC AC
8 2 6 8
2 6 2 4 6
- + - +
+ - + - Panel 1 Panel 2
Panel Panel
Inverter Panel
- -
sirco-mc_051_a_1_gb_cat
sirco-mc_010_a_1_gb_cat
1 3 5 1 3 5
AC AC
2 4 6 2 4 6
+ + - + + -
Panel Inverter Panel Panel Inverter
1 3 5 7
sirco-mc_052_a_1_gb_cat
2 4 6 8
+ + - -
Inverter
Inverter
Panel
Panel
> Buildings.
switches
Strong points
Conformity to standards
Function
> IEC 60947-3
SIRCO MV PV are manually operated multipolar load break switches. They make and break
under load conditions and provide optimum safety isolation for any PV circuit. > IEC 60364-4-410
> IEC 60364-7-712
Advantages
Modular device Patented switching technology Approvals and certifications(1)
SIRCO MV PV are devices whichare DIN-rail or SIRCO MV PV benefit from proven breaking
backplate mountable and can be integrated into technology based on a system of double
a modular panel with a 45 mm front cut-out. break contacts with arc extinguishing
chambers. (1) Product reference on request.
A complete solution
References
SIRCO MV PV 800 VDC - DIN rail or back plate mounting
Rating Circuit No. of Shaft for external
Switch body Direct handle External front handle Auxiliary contact Bridging bar
(A) type poles front handle
63 A 3P 22PV 3106
S0 Type S0 type
Black IP55 150 mm
(1)(2)
1491 0111 1409 0615
80 A 3P 22PV 3108 Black IP65 200 mm 1 contact
(2)
1493 0111 1409 0620 NC+NO
Red / Yellow IP65 320 mm 2299 0001(3)
Blue M0b
(1) 1494 0111(2) 1409 0632 1 contact 2 NC
Single PV 2299 5042 1 piece
100 A 3P 22PV 3110 2299 0011(3)
circuit Blue M0 type 2209 0016
S1 type S1 type 1 contact NO
2299 5022
Black IP55 200 mm 3999 0701
1411 2111(2) 1401 0620 1 contact NC
125 A 3P 22PV 3012 Black IP65 320 mm 3999 0702
1413 2111(2) 1401 0632
Red / Yellow IP65 400 mm
1414 2111(2) 1401 0640
160 A 3P 22PV 3016
(1) Standard.
(2) Defeatable handle.
(3) Signalling contact only.
63 A 4P 22PV 4106
S0 Type S0 type
Black IP55 150 mm
(1)(2)
1491 0111 1409 0615
80 A 4P 22PV 4108 Black IP65 200 mm 1 contact
(2)
1493 0111 1409 0620 NC+NO
Red / Yellow IP65 320 mm 2299 0001(3)
Blue M0b
(1) 1494 0111(2) 1409 0632 1 contact 2 NC
Single PV 2299 5042 2 pieces
100 A 4P 22PV 4110 2299 0011(3)
circuit Blue M0 type 2209 2016
S1 Type S1 type 1 contact NO
2299 5022
Black IP55 200 mm 3999 0701
1411 2111(2) 1401 0620 1 contact NC
125 A 4P 22PV 4012 Black IP65 320 mm 3999 0702
1413 2111(2) 1401 0632
Red / Yellow IP65 400 mm
1414 2111(2) 1401 0640
160 A 4P 22PV 4016
(1) Standard.
(2) Defeatable handle.
(3) Signalling contact only.
Accessories
Direct operation handle
M0b type direct handle
acces_268_a_2_cat
Rating (A) Handle colour Reference
63 ... 160 Blue 2299 5042(1)
(1) Standard.
M0b handle
M0 tpe compact direct operation handle
Rating (A) Handle colour Reference
acces_285_a_2_cat
63 ... 160 Blue 2299 5022
M0 handle
acces_279_a_2_cat
solar cell strings, or located close to the Opening the door when the switch is on
inverter, we recommend the use of a door "ON" position is possible by defeating the
interlocked external handle for safety. interlocking function with the use of a tool
(authorised persons only). The interlocking
function is restored when the door is
re-closed.
S0 type handle
acces_284_a_2_cat
S1 type handle - Front operation I - 0
Handle
Rating (A) Handle External IP(1) Reference
colour
63 ... 160 S1 type Black IP55 1411 2111(2) S1 type handle
63 ... 160 S1 type Black IP65 1413 2111(2)
63 ... 160 S1 type Red/Yellow IP65 1414 2111(2)
(1) IP: protection degree according to IEC 60529 standard.
(2) Defeatable handle.
- 150 mm
- 200 mm Other lengths: Please consult us.
For SIRCO MV PV
Rating (A) Handle type Length (mm) Reference
63 ... 160 S0 type 150 mm 1409 0615 Shaft for S0 type handle for
SIRCO MV PV 63 ... 160 A
63 ... 160 S0 type 200 mm 1409 0620
63 ... 160 S0 type 320 mm 1409 0632
acces_369_a_1_cat
Auxiliary contact
Use
M-type U-type
Signalisation of positions 0 and I by Pre-break and signalisation by NO or NC
NO+NC or 2 NO auxiliary contacts. They auxiliary contact.
can be mounted on the right side on the Max 2 auxiliary contacts.
sircm_048_a_1_x_cat
2(1".,5/5
4OSN@TWHKH@QXBNMS@BS
sircm_075_b_2_cat
modules can be installed.
M type
Rating (A) Contact(s) Contact type Reference
63 ... 160 1 contact NO + NC 2299 0001(1)
M type U type
63 ... 160 1 contact 2 NC 2299 0011(1)
(1) Signalling contact only.
1 2 1 2
U type
Rating (A) Contact(s) Contact type Reference
63 ... 160 1 AC NO 3999 0701
sircm_098_a_1_cat
63 ... 160 1 AC NC 3999 0702
M type
Auxiliary contact configurations for SIRCO MV PV
1. Maximum 2 "U" type auxiliary contacts.
2. Maximum 2 "M" type auxiliary contacts modules (4 A/C).
Terminal shrouds
Use Advantage
Top and bottom protection against direct contact Perforations allow remote thermographic
with the connection parts (set of 2 units). inspection without the need to remove the
shrouds. The terminal shrouds also provide phase
separation.
For SIRCO MV PV
Rating (A) No. of poles Position Reference
63 ... 160 3P top and bottom 2294 3016
63 ... 160 4P top and bottom 2294 4016
Enclosed switches
Our SIRCO MV PV can be delivered For local safety disconnection, SOCOMEC Available on request:
enclosed, please consult us. Close to the - a leader on the market - offers the widest - Enclosures made of steel or stainless steel
installation, they guarantee: range of enclosed switches. Whatever the sheet metal (painted for sea environments
Disconnection under DC load between the level of safety is, we are able to meet all or brushed), or insulating materials
inverters and PV generators (necessary your requirements (disconnection, switching - Specific colours (enclosure paint, handle)
according to the IEC 60364-712 standard). for mechanical maintenance, emergency - Specific dimensions
breaking).
- Specific connections: class II quick
- Enclosed solar load break switches connectors
- Enclosed fuse combination switches
- Enclosed changeover switches For any request of customised products,
- Complete integrated equipment please consult us.
Connection
Maximum Cu rigid cable cross-section (mm) 70 70 70 70 70
Tightening torque min (Nm) 4 4 4 4 4
Tightening torque max (Nm) 5 5 5 5 5
Mechanical characteristics
Operating effort (Nm) 4.2 4.2 4.2 4.2 4.2
Weight of a 3 pole device (kg) 0.7 0.7 0.7 0.7 0.7
Weight of a 4 pole device (kg) 0.9 0.9 0.9 0.9 0.9
Dimensions
SIRCO MV PV 63 to 160 A
Direct front operation External front operation
110 min.
2 A 2 B 357 max. C D
76 109 135 69,9 37 44
64 35 26 61 29,5
8,8 8,8
124,6
131,4
71
189
88
sircm_058_c_1_x_cat
70
6 26
53 M5 1
S0 type IP55 with 2 xing clips IP65 with 4 xing screws With xing nut
40 40 3
I
90
13.5
71 27 47
sircm_038_a_1_gb_cat
88
28
28
22.5
37
37 31
Front operation
Handle type Direction of operation Door drilling
40 40
0
90
27 47
78
poign_039_a_1_gb_cat
I
28
28
70
44 37 31
SIRCO_307_b_1_gb_cat
+ + -
Load Load
> Buildings.
switches
Strong points
Function
Conformity to standards
SIRCO PV are manually operated multipolar load break switches.
They make and break under load conditions and provide safety isolation for any low voltage > IEC 60947-3
circuit dedicated to photovoltaic applications. > IEC 60364-4-410
> IEC 60364-7-712
> UL 98B(1)
Advantages (1) See page 158.
References
Single PV circuit 750 VDC - Back plate mounting
Number of Number of
poles of the pole(s) in series Shaft for
Rating (A) Circuit type device per polarity Switch body Direct handle(2) External handle external handle Bridging bars
100 A 26PV 3010
125 A 26PV 3012
160 A 26PV 3016
2609 0025
200 A 26PV 3020 S2 type
200 mm
J1 type Black IP55
1400 1020
250 A 26PV 3025 Black 1421 2111(1)
320 mm
1112 1111(1) Black IP65
315 A 26PV 3031 1400 1032(1)
Red 1423 2111
500 mm
1113 1111 Red IP65
400 A 26PV 3040 1400 1050
1424 2111
2609 2050
500 A 26PV 3050
630 A 26PV 3063
Single PV circuit 3P 2P+, 1P- 2609 0080
800 A 26PV 3080
1000 A 26PV 3100 200 mm
J4 type S4 type 2609 1100
1401 1520
1250 A 26PV 3120 Black Black IP65
320 mm
1142 1111(1) 1443 3111(1) (1)
1600 A 26PV 3160 1401 1532 2609 1160
Red Red IP65
400 mm
1143 1111 1444 3111
2000 A 26PV 3200 1401 1540 2609 1200
2500 A
Please consult us - - -
3200 A
(1) Standard.
(2) Other types of operation handle available. see "Accessories" pages.
(1) Standard.
(2) Other types of operation handle available. see "Accessories" pages.
References (continued)
Single PV circuit 1000 VDC - Back plate mounting
Number of Number of
poles of the pole(s) in series Shaft for
Rating (A) Circuit type device per polarity Switch body Direct handle(2) External handle external handle Bridging bars
100 A 26PV 4010
125 A 26PV 4012
160 A 26PV 4016
2609 2025
200 A 26PV 4020 S2 type
200 mm
J1 type Black IP55
1400 1020
250 A 26PV 4025 Black 1421 2111(1)
320 mm
1112 1111(1) Black IP65
315 A 26PV 4031 1400 1032(1)
Red 1423 2111
500 mm
1113 1111 Red IP65
400 A 26PV 4040 1400 1050
1424 2111
2609 4050
500 A 26PV 4050
630 A 26PV 4063
2609 2080
800 A Single PV circuit 4P 2 P+, 2 P- 26PV 4080
1000 A 26PV 4100 2x
200 mm
J4 type S4 type 2609 1100
1250 A 26PV 4120 1401 1520
Black Black IP65
320 mm
1142 1111(1) 1443 3111(1) 2x
1600 A 26PV 4160 1401 1532(1)
Red Red IP65 2609 1160
400 mm
1143 1111 1444 3111 2x
2000 A 26PV 4200 1401 1540
26091200
2500 A
Please consult us - - - -
3200 A
(1) Standard.
(2) Other types of operation handle available. see "Accessories" pages.
(1) Standard.
(2) Other types of operation handle available. see "Accessories" pages.
(1) For an operating voltage of 1200 VDC, the 3 poles at the front of the device must be connected in series for one polarity, and the 3 poles at the rear must be connected in series for the other.
(2) Other types of operation handle available. See "Accessories" pages.
(3) Standard.
(1) For an operating voltage of 1500 VDC, the 4 poles at the front of the device must be connected in series for one polarity, and the 4 poles at the rear must be connected in series for the other.
Accessories
Direct operation handle
acces_114_a_1_cat
Red 1113 1111
100 800
Black 2799 7052
acces_129_b_1_cat
C1 type
Red 2799 7053
6/8 P
Black 1132 1111(1)
J3 type
acces_153_a_1_cat
Red 1133 1111
B2 type handle
Black 2799 7012
C2 type
Red 2799 7013
1000 1250 3/4/6/8 P
Black 1142 1111(1)
J4 type
Red 1143 1111 C1-type handle
Black 2799 7012 C2-type handle
C2 type
Red 2799 7013
3/4 P
1600 2000 Black 1142 1111(1)
J4 type
Red 1143 1111
6/8 P V1 type Black 2799 7074(1)
(1) Standard.
acces_355_a
J1 type handle
acces_151_a_2_cat
Front operation
Rating (A) No. of poles Handle Handle colour External IP(1) Reference S4 type handle
Black IP55 1421 2111(1)
3/4/6/8 P S2 type Black IP65 1423 2111
acces_286_a_2_cat
acces_260_a_2_cat
to engage the extension shaft with a
misalignment of up to 15 mm.
Description Reference
Shaft guide 1429 0000
acces_187_a_1_cat
door and the handle lever.
To be ordered
Handle colour External IP(1) in multiples of Reference
Black IP65 1 1493 0000
(1) IP: protection degree according to IEC 60529 standard.
acces_198_a_1_cat
Handle To be ordered
colour in multiples of Handle Reference
Light grey 50 S1, S2, S3 type 1401 0001
Dark grey 50 S1, S2, S3 type 1401 0011
Accessories (continued)
Auxiliary contact
Use Characteristics
Pre-break and signalling of positions 0 and I: -.-" "(/VHSGEQNMSNODQ@SHNM
SN-.-"@TWHKH@QXBNMS@BSR Connection to the control circuit
SN-.
-"@TWHKH@QXBNMS@BSR 6.35 mm fast-on terminal.
SNKNVKDUDK-.-"@TWHKH@QXBNMS@BSR
Electrical characteristics
30 000 operations.
acces_076_a_1_cat
NO/NC contact for 3/4 poles
Rating (A) Position A/C Reference
1st 2699 0031
100 3200
2nd 2699 0032
Characteristics
Operating current Ie (A)
230 VAC 400 VAC 24 VDC 48 VDC
Contact type AC-12 AC-15 AC-12 AC-15 DC-12 DC-14 DC-12 DC-14
-.-" 16 4 12 3 16 1 2.5 0.2
-"+NVKDUDK 16 4 12 3 16 1 4 0.3
-.
-" 16 4 12 3 16 1 4 0.3
Terminal shrouds
Use Advantage
Top or bottom protection against direct Perforations allow remote thermographic
contact with terminals or connection parts. inspection without the need to remove the
acces_077_a_1_cat
shrouds.
The terminal shrouds also provide phase
separation for SIRCO PV from
SN
Single PV circuit Single PV circuit Dual PV circuit 750 VDC or single Dual PV circuit 1000 VDC or
750 VDC 1000 VDC PV circuit 1200 VDC single PV circuit 1500 VDC
Quantity to be Quantity to be Quantity to be Quantity to be
Rating (A) ordered Reference ordered Reference ordered Reference ordered Reference
100 500 1 2694 3021 1 2694 4021 2 2694 3021 2 2694 4021
630 800 1 2694 3051 1 2694 4051 2 2694 3051 2 2694 4051
Terminal screens
Use
acces_079_a_1_cat
Top and bottom protection against direct contact with terminals or connection parts.
Single PV circuit Single PV circuit Dual PV circuit 750 VDC or Dual PV circuit 1000 VDC or
750 VDC 1000 VDC single PV circuit 1200 VDC single PV circuit 1500 VDC
Rating (A) Position Reference Position Reference Position Reference Position Reference
100 500 Top or bottom 2698 3020 Top or bottom 2698 4020 Top or bottom 1509 3025 Top or bottom 1509 4025
630 800 Top or bottom 2698 3050 Top or bottom 2698 4050 Top or bottom 1509 3063 Top or bottom 1509 4063
1000 1250 Top or bottom 2698 3080 Top or bottom 2698 4080 Top and bottom 1509 3080 Top and bottom 1509 4080
1600 Top or bottom 2698 3120 Top or bottom 2698 4120
Top and Top and Top or bottom 2698 3199 Top or bottom 2698 4199
2000 2698 3199 2698 4199
bottom bottom
Inter-phase barrier
Use For 100 to 800 A SIRCO PV, the inter-phase
Safety isolation between the terminals. barriers allow insulation between poles
connected in series.
acces_036_a_1_cat
Rating (A) No. of poles Pack Reference
100 500 3P 2 pieces 2998 0023
100 500 4P 3 pieces 2998 0024
630 800 3P 2 pieces 2998 0013
630 800 4P 3 pieces 2998 0014
1000 3200 3P/4P - included
acces_334_a_1_cat
Single PV circuit Single PV circuit Dual PV circuit 750 VDC or Dual PV circuit 1000 VDC or
750 VDC 1000 VDC single PV circuit 1200 VDC single PV circuit 1500 VDC
Quantity to be Quantity to be Quantity to be Quantity to be
Rating (A) ordered Reference ordered Reference ordered Reference ordered Reference
100 315 1 2609 0025 1 2609 0025 2 2609 0025 2 2609 0025
400 500 1 2609 2050 1 2609 4050 2 2609 2050 2 2609 4050
630 800 1 2609 0080 1 2609 2080 2 2609 0080 2 2609 2080
1000 1250 1 2609 1100 2 2609 1100 2 2609 1100 4 2609 1100
1600 1 2609 1160 2 2609 1160
2(1) 2609 1200 4(1) 2609 1200
2000 1 2609 1200 2 2609 1200
(1) For 1200 VDC products, order 4 times reference 2609 1200. For 1500 VDC products, order 6 times reference 2609 12000.
1800 A, the padlock on the external front For 6/8 pole: please consult us.
operation handle also locks the door,
Locking using RONIS EL11AP lock (not supplied)
Rating (A) No. of poles Operation Figure Reference
Fig. 3 Fig.4
100 800 3/4 P front direct 1 2699 6008
100 800 3/4 P external front 3 1499 7701
Locking using 230 VAC undervoltage coil (other voltages: please consult us)
acces_158_a_1_x_cat
acces_004_c_1_x_cat
Characteristics
Characteristics according to IEC 60947-3
SIRCO PV - 100 to 400 A
Rated current I (A) 100 A 125 A 160 A 200 A 250 A 315 A 400 A
Rated insulation voltage Ui (V) - 3/4 P device 1200 1200 1200 1200 1200 1200 1200
Rated insulation voltage Ui (V) - 6/8 P device 1500 1500 1500 1500 1500 1500 1500
Rated impulse withstand voltage Uimp (kV) 12(1) 12(1) 12(1) 12(1) 12(1) 12(1) 12(1)
Connection
Maximum Cu rigid cable cross-section (mm) 35 50 70 95 120 185 240
Maximum Cu busbar width (mm) 32 32 32 32 32 32 32
3HFGSDMHMFSNQPTDLHM-L 20 20 20 20 20 20 20
3HFGSDMHMFSNQPTDL@W-L 26 26 26 26 26 26 26
Mechanical characteristics
Durability (number of operating cycles)
.ODQ@SHMFDEENQS-L 10 10 10 10 10 10 10
Weight of a 3 pole device (kg) 2 2 2 2 2 3.5 3.5
Weight of a 4 pole device (kg) 2.5 2.5 2.5 2.5 2.5 4 4
(1) The delivered spacers have to be installed.
Connection
Maximum Cu rigid cable cross-section (mm) 2x150 2x185 2x240 2x240 2x240 - -
Maximum Cu busbar width (mm) 32 40 50 63 63 100 100
3HFGSDMHMFSNQPTDLHM-L 20 40 40 40 40 40 40
3HFGSDMHMFSNQPTDL@W-L 26 45 45 45 45 45 45
Mechanical characteristics
Durability (number of operating cycles)
.ODQ@SHMFDEENQS-L 10 14.5 14.5 37 37 56 56
Weight of a 3 pole device (kg) 3.5 3.5 3.5 8 8 12 12
Weight of a 4 pole device (kg) 4 4 4 10 10 15 15
(1) The delivered spacers have to be installed.
Dimensions
100 to 2000 A - Single PV circuit
Direct front operation External front operation
M Z
J1 J2 Y 1
W
CA
U A
V
K
R 0
AC
BA
AA
G
N
BC
125
1. Terminal shrouds
sirco_198_i_1_x_cat
A. S2 type handle
CA
U1
90
I AD D min. 45
X1 T T T X2 H
F C 18
Overall Terminal
dimensions shrouds Switch body Switch mounting Connection
D F F J1 M M X1 X1
Rating (A) C min AC AD 3p. 4p. G H 3p. J1 4p. K BC 3p. 4p. N R T U U1 V W 3p. 4p. X2 Y Z AA BA CA
100 250 25 25 21.5 160 130
125 135 290 60 180 230 116 79 80 105 34 160 210 80 5.5 50 11 33 33 27 3.5 22.5 15
315 500 115 35 35 26.5 170 140
630 800 160 165 402 90 230 290 170 128 75 135 55 210 270 140 7 65 45 45 41.5 13 42.5 37.5 37.5 5 37.5 260 220 20
1000 50 61 15 321
103 280 360 127.5 167.5 255 335 47.5 47.5 7 46.5
1250 215 221 470 - 140 - 165 175 9 - 60 - 65 16x11 - 330 - -
1600 2000 118 372 492 173.5 233.05 492 467 90 44 12.5x5 53.5 53.5 8 47.5 288
100 to 2000 A - Dual PV circuit and single PV circuit from 1200 to 1500 VDC
Direct front operation External front operation
A Z1
10 M Z
Y Y B
U 8.5 1
W
CA
2 sirco-pv_029_b_1_x_cat
A
350
AC
BA
AA
II I
0
125
L1
CA
H HA
E min.
I
X T T T H
60 45
J C 18
Terminal Switch
Overall dimensions shrouds Switch body mounting Connection
A A M M X X
Rating (A) 3p. 4p. C E min AC H HA J 3p. J 4p. 3p. 4p. N T U V W 3p. 4p. Y Z Z1 AA BA CA
100 250 25 21.5
262 312 218 208 436 280 148 223 273 196 246 116 50 11 61 61 3.5 30 124 160 130 15
315 500 25 35 26.5
630 800 319 379 295 285 513 401 225 272 332 246 306 176 65 45 41.5 13 70.5 65.5 5 43 180 260 220 20
1000 50 60.5
386 466 459 306.5 386.5 255 336 80 15 48 48 7 253.5 321 25.5
1250 375 425 577 298 29 250 60 65 66.5
1600 2000 478 598 461 388.5 518.5 357 467 120 90 44 12.5 54 54 8 255.5 288 15
28
I 37
125
poign_010_a_1_gb_cat
47
28
24
14 14
26
45
37
.5
45
73
3.
5
20 20
S3 type
Front operation
Handle type Direction of operation Door drilling
S3 type I
78
90
37
40
poign_035_a_1_gb_cat
210
47
28
61
S4 type
Front operation
Handle type Direction of operation Door drilling template
O 26
37
78 90 4 5.5
28
37
350
40
47
I
poign_011_a_1_gb_cat
24
20 20
26
.5
47
45
28
73
3.
5
28
60
S5 type
Front operation
Handle type Direction of operation Door drilling
S5 type
with V Escutcheon 50
I
4 6,5
90
poign_037_a_1_gb_cat
50
0
498
31
71
102
V1 type
Front operation
Handle type Direction of operation Door drilling
V1 type 50
I
4 6,5
545
50
poign_011_a_1_gb_cat
31
122
sirco_031_a_1_x_cat
15
81
13
12
11
19
22.5 65 22.5 5
9
128,5
100
12,5
sirco_033_a_1_x_cat
sirco_032_a_1_x_cat
33
12,5
22,95
11
15 30 5
5 8
33 47 8,5 5
60 60
130
12,5
sirco_034_a_1_x_cat
12,5
22,95
15 30 5
5 8
60 60
71
> Buildings.
Load break
sirco-pv_016_a_1_cat
Strong points
SIRCO MOT PV are three or four pole motorised load break switches.
They make and break under load conditions and provide safety isolation for any low voltage A complete solution
circuit dedicated to photovoltaic applications.
> SUNSYS IFB
(Intelligent Field Box).
Advantages Smart connection box to link
Patented safety disconnection system for General characteristics solar panels to the inverter.
firefighters q 2 stable positions (I, 0).
With its remote electrical control, the q /NRHSHUDAQD@JHMCHB@SHNM
2(1".,.3/5B@MADTSHKHRDCSNOQNUHCD q 43., -4RDKDBSNQ
safety disconnection for firefighters, meeting q /@CKNBJHMFHMONRHSHNMONRHSHNM(VHSGNOSHNM
the remote disconnection requirements of the
q Up to 1000 VDC.
installation, closing to facilitate periodic tests
coff_380_a_1_cat
References
2(1".,.3/55#"
2(1".,.3/55#"
Accessories
Bridging bars for connecting poles in series
Use
The bridging bars facilitate the connection "NMMDBSHNMCH@FQ@LR2DD/NKDR
of poles in series, allowing the below connections in serie", page 133.
configurations:
q Bottom/Bottom
q Top/Top
q Top/Bottom
q Top/Bottom
Number of poles of
Rating (A) the device in series Pack Reference
2 1 piece 2609 0025
4 2 pieces 2609 2025
400 ... 630 2 1 piece 2609 0063
400 ... 630 4 2 pieces 2609 2063
Auxiliary contact
Use Connection to the control circuit
/QDAQD@J@MCRHFM@KHR@SHNMNEONRHSHNM( !X
LLE@RSNMSDQLHM@K
SN-.-"@TWHKH@QXBNMS@BSR@R Electrical characteristics
standard). 30 000 operations.
Low level auxiliary contacts:
@BBDR>>@>>B@S
/KD@RDBNMRTKSTR
Characteristics
Operating current Ie (A)
Nominal 250 VAC 400 VAC 24 VDC 48 VDC
Rating (A) current (A) AC-13 AC-13 AC-13 AC-13
200 630 16 12 8 14 6
References
RUQ>>@>>B@S
Rating (A) Contact(s) Reference
200 630 2nd 4109 0021
Terminal shrouds
acces_206_a_2_cat
bars connected.
Terminal screens
Use
Top and bottom protection against direct contact with
terminals or connection parts.
@BBDR>>@>>B@S
400 ... 630 / top and bottom 1509 3063
400 ... 630 / top and bottom 1509 4063
Use
Enables padlocking in position I (product can be padlocked in
position 0 as standard).
@SXR>>@>>B@S
Accessories (continued)
Key handle interlocking system
Use
With the product in manual mode, it enables Locking in both positions (I-0) requires,
KNBJHMFHMONRHSHNMTRHMF@1.-(2$+ / in addition, the 2 position padlocking
lock. Factory fitted. accessory.
atys_101_a_1_cat
Rating (A) Reference
200 630 1509 1006
"G@Q@BSDQHRSHBR@BBNQCHMFSN($"
200 to 630 A
Thermal current Ith at 40C 200 A 250 A 400 A 500 A 630 A
Rated insulation voltage Ui (V) 1200 1200 1200 1200 1200
Rated impulse withstand voltage Uimp (kV) 8 8 12 12 12
Power supply
230 VAC min./max. (VAC)
Connection
Rigid Cu cable cross-section (mm2) 120 240 W W
,@WHLTL"TATRA@QVHCSGLL 32 32 40 40 40
3HFGSDMHMFSNQPTDLHM-L 20 20 40 40 40
Mechanical characteristics
Durability (number of operating cycles)(1) 8000 8000
Weight of a 3 pole device (kg)
Weight of a 4 pole device (kg) 6 6 8 8 8
(1) Improved endurances: Please consult us.
Dimensions
2(1".,.3/5SN
J
M J1
U
3
W
CA
V
6
=
Fix. 195
Fix. 180
101
AC
BA
AA
223
=
140
CA
10.5 Y
2
85
10 X T T T 11
F Z2
4
A H
C
sirco_311_b_1_x_cat
1
Fix. 195
Fix. 180
138
W 20 5
7
CA
9 U
101
50.5
1. Locking bracket 4. Terminal shrouds
2. Maximum handle radius, operating angle 2 x 90. 5. Dimension of the cut-out
3. Mounting spacers. 6. Handle
Terminal Switch
Overall dimensions Switch body Connection
Rating (A) shrouds mounting
A 3p. A 4p. C AC F 3p. F 4p. H J 3p. J 4p. M 3p. M 4p. T U V W X 3p. X 4p. Y Z Z1 AA BA CA
200
280 328 184 160 210 30 11 33 33
160 130
280 328 184 160 210 30 11 33 33
160 130
400 394
400 221 244 304 210 13
190 260 220 20
394
400 221 244 304 210 13
190 260 220 20
630 394
400 221 244 304 210 13
190 260 220 20
/NKDBNMMDBSHNMRHMRDQHDR(1)
3 poles - bottom / top 4 poles - bottom / bottom
-
RHQBN>>A>>FA>B@S
RHQBN>>A>>FA>B@S
+
+ -
Load
Load
(1) Other connections: refer to mounting instructions
sircm_133_a
sircm_132_a
Conformity to standards(1)
sircm_174_a
Function
SIRCO M UL/CSA non fusible disconnect switches are compact modulable and modular UL508 non-metallic
switches. They make and break under load conditions and provide safety isolation for any low polycarbonate 4.4x enclosed
voltage circuit, particularly for machine and control circuits. SIRCO M
S00 type I - 0
Black 1P
16 A 3P 2205 3000 2200 3000
3R, 12(1) 2200 1000
1473 1111
Red/Yellow
3R, 12(1) 1P
20 A 3P 2205 3001 2200 3001
1474 1111 2200 1001
Black
4, 4X(1) S00 and 1P
1P
25 A 3P 2205 3002 2200 3002 147D 1111 S0 type 2294 1005(3)
150 mm
2200 1002
3P
Red/Yellow 5.9 in M type
4, 4X(1) 1407 0515 1 AC 2294 3005(3)
147E 1111 NO + NC
Blue 1P 2299 3409
32 A 3P 2205 3003 2200 3003 200 mm 2299 0001
2299 5012 2200 1003
S0 type 7.9 in
I-0 1407 0520 1 AC 2 NC
Black 2299 0011
1, 3R, 12(1) 320 mm
1P
40 A 3P 2205 3004 2200 3004 1483 1111 12.6 in
2200 1004
1407 0532(2)
Red/Yellow
1, 3R, 12(1)
1484 1111 1P
63 A 3P 2205 3006 2200 3006
2200 1006 1P
Black 4, 4X(1) 2294 1009(3)
148D 1111
3P
Red/Yellow 1P 2294 3009(3)
80 A 3P 2205 3008 2200 3008 4, 4X(1) 2200 1008
148E 1111
Unswitched
No. of Enclosed Switched fourth Unswitched protective earth
Rating (A) poles switches Enclosure size pole module neutral pole module Auxiliary contacts Terminal shrouds
Configuration
2. Additional pole.
2.67
8.27
4.37
210
68
sircm-ul_007_a_1_x_cat
sircm-ul_008_a_1_x_cat
3.62 111
152.5
4.37
6.38
111
0.13 92
150
162
5.9
7.32
198
6
7.8
186
3.62
92
3.4
0.02
0.4
4
0.16
0.4
0.02
3.9
99
4.94
125.5
Size 1 Size 2
Accessories
Direct operation handle
acces_277_a_2_cat
16 80 Blue M00 type 2299 5012
M00 handle
acces_264_a_2_cat
Front and right side handles I - 0
Rating (A) Handle colour Handle Nema type Reference
16 80 Black S00 type 3R, 12 1473 1111
16 80 Red/Yellow S00 type 3R, 12 1474 1111 S00 handle
16 80 Black S00 type 4, 4X 147D 1111
16 80 Red/Yellow S00 type 4, 4X 147E 1111
16 80 Black S0 type 1, 3R, 12 1483 1111
acces_279_a_2_cat
16 80 Red/Yellow S0 type 1, 3R, 12 1484 1111
16 80 Black S0 type 4, 4X 148D 1111
16 80 Red/Yellow S0 type 4, 4X 148E 1111
Accessories (continued)
Shaft guide for external handle
Use
This accessory enables handle to engage extension shaft with a misalignment of
up to 15 mm.
Required for a shaft lenght from 320 mm.
acces_260_a_2_cat
Handle type Reference
S00 and S0 1419 0000
sircm_072_b_1_cat
40 1P switched 2200 1004
63 1P switched 2200 1006(1) switches into a 4 pole.
80 1P switched 2200 1008(1)
(1) Not UL.
N or PE
63 80 1P unswitched
N or PE
switch into a 3-pole + solid
(1) Not UL. neutral.
sircm_078_a_1_gb_cat
Earth module
N or PE
Use
N or PE
N or PE
N or PE
Terminal shrouds
Use
Top and bottom additional protection Perforation on each terminal cover
against direct contact with the enables remote thermographic
terminals or connection parts. 1 or 3 inspection without dismantling.
pole are available.
sircm_049_a_1_cat
sircm_075_b_2_cat
They can be mounted on the left or A300.
on the right side of the device.
sircm_081_a_1_x_cat
Auxiliary contacts configurations for SIRCO M
Conversion kit
Use
sircm_050_c_2_cat
sircm_097_b_2_x_cat
These accessories enable the assembly of
2 switches in order to achieve:
- 6 or 8 pole switches
- 3 or 4 pole open or close transition
changeover switches.
Conversion kit for 3 and
Conversion kit for 6 or 8 pole 4-pole changeover switches
load break switches (I - 0 - II) or (I - I+II - II)
Rating (A) Type Reference
16 80 Load break switches 6/8 P 2269 6009
16 80 Changeover switch 3/4 pole (I - 0 - II) 2209 6009
sircm_086_b_1_cat
16 80 Changeover switch 3/4 pole (I - I+II - II) 2299 6009
Use
This kit enables direct mounting of The external handle is quick and easy
the switch on the panel door or on to install due to an internal locking
the right or left side of the panel. nut mounted on the inside of the
enclosure.
sircm_051_b_2_cat
Characteristics
Characteristics according to UL508/CSA22.2#14 suitable as motor disconnect
SIRCO M UL508 - 16 to 80 A
General use rating 16 A 20 A 25 A 32 A 40 A 63 A 80 A
Short circuit rating at 600 VAC (kA) 65 65 65 65 10/65 50/65 50/65
Type of fuse J J J J J J J
Max fuse rating (A) 30 30 30 30 60/30 100/60 100/60
Connection terminals
Solid - 1 wire #14 - #10 #14 - #10 #14 - #10 #14 - #10 #14 - #10 #14 - #10 #14 - #10
Solid - 2 wires 2x #12 2x #12 2x #12 2x #12 2x #12 2x #12 2x #12
Stranded - 1 wire #14 - #4 #14 - #4 #14 - #4 #14 - #4 #14 - #4 #14 - #1 #14 - #1
Stranded - 2 wires 2x (#14 - #12) 2x (#14 - #12) 2x (#14 - #12) 2x (#14 - #12) 2x (#14 - #12) 2x (#10 - #6) 2x (#10 - #6)
Auxiliary contacts
Electrical characteristics A300 A300 A300 A300 A300 A300 A300
Mechanical characteristics
Endurance (number of operating cycles) 100 000 100 000 100 000 100 000 100 000 100 000 100 000
Operating torque (lbs.in/Nm) 7/0.8 7/0.8 7/0.8 7/0.8 7/0.8 8.9/1 8.9/1
Connection
Minimum Cu cable cross section (mm) 1.5 1.5 1.5 1.5 1.5 2.5 2.5
Maximum Cu cable section (mm2) 16 16 16 16 16 35 35
Tightening torque min / max (Nm) 2 / 2.2 2 / 2.2 2 / 2.2 2 / 2.2 2 / 2.2 3.5 / 3.85 3.5 / 3.85
(1) A/B: Category with index A = frequent operation - Category with index B = infrequent operation.
(2) The power value is given for information only, the current values vary from one manufacturer to another.
(3) For a rated operating voltage Ue = 400 VAC.
3.19
81 2.95
2.87 75
73 F 2.52 F 1
2.52 M 1 64 M 2
64 2 1
1 2
2
sircm_052_b_1_gb_cat
sircm_053_b_1_gb_cat
2.67
AC
68
2.68
N
AC
90
68
G
2.79
1.77
3.15
2.68
71
AC
68
45
80
N
1.61
41
sircm-ul_002_a_1_gb_cat
0.98
25 1.73
44 0.35 F1 F1 0.35
8.8 T 8.8
0.23
6 M5
1.96
50
1. Position for 1 switched fourth pole module (1 per device max.) or 1 unswitched neutral pole or 1 earth module or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 additional blocks.
Overall dimensions Terminal shrouds Switch body Switch mounting Connection
Rating (A) Units D min D max E min E max AC F F1 G J M N T
in 1.18 9.25 3.94 14.64 4.33 1.77 0.59 2.67 0.59 1.18 2.95 0.59
16 to 40
mm 30 235 100 372 110 45 15 68 15 30 75 15
in 1.18 9.25 3.93 14.64 4.33 2.06 0.69 2.99 0.69 1.38 3.35 0.69
63 to 80
mm 30 235 100 372 110 52.5 17.5 76 17.5 35 85 17.5
Direct front handle for 6/8-pole load break switches External front handle for 6/8-pole load break switches
or 3/4-pole changeover switches or 3/4-pole changeover switches
F
J 3.50
F2 89
1 X M 2.06 1 E 1.42
2 2 3.07 36
52.5 78
sircm_055_c_1_gb_cat
2.79
2.67
71
1.77
68
G
N
45
0.24
0.35 F1 F1 0.35 6 1.69 1.36
8.8 T T 0.29 8.8 43 34.7
2.06 7.5
52.5
1. Position for 1 switched fourth pole module (1 per device max.) or 1 unswitched neutral pole or 1 earth module or 1 auxiliary contact.
2. Position for 1 auxiliary contact only.
Note: Maximum of 4 additional blocks.
0 0
1.10
28
1.42
36 1.22
31
sircm-ul_015_a_1_gb_cat
0.53
13.5
0.88
22.5
I I 1.57
40
0.11
3.07 90 90 3
78 4 0.27
47
0.53
13.5
poign_048_b_1_gb_cat
2.79
71
0 0
1.10
28
1.42
36 1.22 0.88
31 22.5
Front operation
Handle type Direction of operation Door drilling
Typ S00
With 4 xing screws With xing nut
Changeover switches 0 0.53
or 13.5
1.45 0.88
I+II
37 22.5
90
sircm_013_b_1_gb_cat
2.79
90
71 0.12
40
3
2.79
71
I II
1.41 4 0.27
1.10
36 47
28
sircm_100_a_1_cat
Strong points
Conformity to standards(1)
References
UL98 Non Fusible Disconnect switches
S00 type I - 0 1P
30 A 3P 2201 3003
Black 2201 1003
4, 4X
147D 1111
150 mm 5.9 in M type
Red/Yellow 1407 0515 1 AC
1P
4, 4X NO + NC
2294 1011(3)
Blue 147E 1111 200 mm 7.9 in 1P 1P 1P 2299 0001
60 A 3P 2201 3006
2299 5032 1407 0520 2201 1006 2200 5011(2) 2200 9011(2)
3P
S0 type I - 0 M type
2294 3016(3)
Black 320 mm 12.6 in 1 AC 2 NC
4, 4X 1407 0532(1) 2299 0011
148D 1111
Red/Yellow 4, 4X 1P
100 A 3P 2200 3010 148E 1111 2200 1010
(1) Shaft guide reference 14190000, is required for shaft length over 15.7 inches (400 mm).
(2) Not UL.
(3) Top and bottom.
Accessories
Direct operation handle
acces_283_a_2_cat
Rating (A) Colour Handle Reference
30 ... 100 Blue M01 type 2299 5032
M01 handle
acces_264_a_2_cat
enclosure when the switch is in the "ON" interlocking function with the use of a tool
position (only if the handle is fitted on the (authorised persons only).
door). The interlocking function is restored
when the door is closed. The handle is
padlockable with 3 padlocks.
S00 handle
Front and right side handles I - 0
Rating (A) Handle colour Handle Nema type Reference
acces_279_a_2_cat
16 80 Black S00 type 3R, 12 1473 1111
16 80 Red/Yellow S00 type 3R, 12 1474 1111
16 80 Black S00 type 4, 4X 147D 1111
16 80 Red/Yellow S00 type 4, 4X 147E 1111
16 80 Black S0 type 1, 3R, 12 1483 1111
16 80 Red/Yellow S0 type 1, 3R, 12 1484 1111
16 80 Black S0 type 4, 4X 148D 1111
16 80 Red/Yellow S0 type 4, 4X 148E 1111
S0 handle
- 320 mm.
sircm_072_b_1_cat
Solid neutral pole
Rating (A) No. of poles Type Reference Use
30 100 1P unswitched 2200 5011(1) Transforms the 3-pole
N or PE
N or PE
switch into a 3-pole + solid
(1) Not UL.
neutral.
sircm_078_a_1_gb_cat
Earth module
N or PE
Use
N or PE
N or PE
N or PE
Rating (A) No. of poles Type Reference
30 100 1P unswitched 2200 9011(1) Adds 1 earth module pole to the
(1) Not UL. switch-disconnector.
Terminal shrouds
Use
Top and bottom additional
protection against direct contact Perforation on each terminal cover
sircm_049_a_1_cat
with the terminals or connection enables remote thermographic
parts. 1 or 3 pole are available. inspection without dismantling.
Use
Pre-break and signalisation of positions 0 Characteristics
and I by NO+NC or 2 NO auxiliary contacts. A300.
sircm_075_b_2_cat
Characteristics
Characteristics according to UL98/CSA22.2#4
SIRCO M UL98 - 30 to 100 A
General use rating 30 A 60 A 100 A
Short-circuit rating at 480 VAC (kA) 100 100 100
Short circuit rating at 600 VAC (kA) 100 100 25
Type of fuse J J J
Max fuse rating (A) 30 60 100
Connection terminals
Solid - 1 wire #12 - #10 #12 - #10 #12 - #10
Stranded - 1 wire #12 - 2/0 #12 - 2/0 #12 - 2/0
Mechanical characteristics
Endurance (number of operating cycles) 10000 10000 10000
Operating torque (lbs.in/Nm) 12.4/1.4 12.4/1.4 12.4/1.4
Auxiliary contacts
Electrical characteristics A300 A300 A300
Connection
Min. connection section/ (mm2) 2.5 2.5 10
Max. connection section/ (mm2) 70 70 70
(1) Category with index A = frequent operation.
(2) A/B: Category with index A = frequent operation - Category with index B = infrequent operation.
(3) The power value is given for information only, the current values vary from one manufacturer to another.
(4) For a rated operating voltage Ue = 400 VAC.
2.95
75 F
2.52 1 1. Position for 1 switched fourth pole module (1 per device max.) or 1
64 M 2 unswitched neutral pole or 1 earth module or 1 auxiliary contact.
1
2 2. Position for 1 auxiliary contact only.
Note: Maximum of 4 additional blocks.
AC
G
sircm_056_c_1_gb_cat
0.24
0.35 F1 T F1 0.35
6 8.8 8.8
2.09
53 M5
sircm-ul_003_a_1_gb_cat
36
3.19
81 3.07
2.52 78 1.18 min./7.91 max. 1.42
64 30 min./201 max. 36
1.02
1.99 26
50.6 0.51
13 1
1
2
2
B C
124.6
131.4
71
4.90
3.15
7.44
5.17
189
80
1.61
41
1.73
44
I I 1.57
40
0.11
3.07 90 90 3
78 4 0.27
47
0.53
13.5
2.79
71
0 0
poign_048_b_1_gb_cat
1.10
28
1.42
36 1.22 0.88
31 22.5
sirco-ul_022_b_1_cat
Strong points
> Reliability.
SIRCO 3 x 200 A
sirco_093_b_1_cat
Conformity to standards(1)
SIRCO 3 x 600 A > IEC 60947-3
> UL98,
Guide WHTY,
Function file E201138 *
SIRCO non fusible disconnect switches are heavy duty switches that break and make power > CSA Pending
circuits on and off load and provide safety isolation. 22.2#4,
These switches are extremely durable and are tested and approved for use in the most
Class 4652-04,
demanding applications.
file 703166
References
3P 2700 3060 3P 3P
2798 3060(4) 3954 3060
600 A
4P 4P
4P 2700 4060 2798 4060(4) 3954 4060
200 mm
3P 2700 3080 S3 type
7.9 inches
Contact holder
800 A 1401 1520
Black 3999 0720(5)
4P 2700 4080 4, 4X
320 mm
Black 143D 3111(1) Contact NO
12.6 Inches
3799 6012 3999 0701
3P 2700 3100 1401 1532 3P 3P
Red/Yellow
4, 4X Contact NC 2798 3120(4) 3954 3120
1000 A 400 mm
143E 3111(1) 3999 0702 4P 4P
4P 2700 4100 15.7 Inches 2798 4120(4) 3954 4120
1401 1540
3P 2700 3120
1200 A
4P 2700 4120
Accessories
Direct operation handle
acces_114_a_1_cat
Accessories (continued)
External operation handle
Use
The interlocking function of the front Opening the door when the switch is in the
acces_150_a_1_cat
external handle prevents the user from "ON" position is possible by defeating the
opening the door of the enclosure when the interlocking function with the use of a tool
switch is in the "ON" position or when the (authorised persons only). The interlocking
switch is padlocked in the "OFF" position function is restored when the door is closed.
(S1, S2, S3 and S4 type handles only). S2 type handle
Front handle I - 0
Rating (A) Handle Colour Nema type Reference
100 ... 400 S2 type Black 1, 3R, 12 142F 2111
100 ... 400 S2 type Red/Yellow 1, 3R, 12 142G 2111
100 ... 400 S2 type Black 4, 4X 142D 2111
acces_166_a_2_cat
acces_152_a_2_cat
100 ... 400 S2 type Red/Yellow 4, 4X 142E 2111
600 1200 S3 type Black 4, 4X 143D 3111
600 1200 S3 type Red/Yellow 4, 4X 143E 3111
600 1200 S4 type Black 4, 4X 144D 3111
600 1200 S4 type Red/Yellow 4, 4X 144E 3111
S3 type handle
Front handle heavy duty I - 0 with metallic lever S4 type handle
Rating (A) Handle Colour Nema type Reference
acces_236_a_2_cat
100 ... 400 S2 type Black 4, 4X 142D 2911
100 ... 400 S2 type Red/Yellow 4, 4X 142E 2911
600 1200 S3 type Black 4, 4X 143D 3911
600 1200 S3 type Red/Yellow 4, 4X 143E 3911
600 .... 1200 S4 type Black 4, 4X 144D 3911
Heavy duty S2 type handle
600 1200 S4 type Red/Yellow 4, 4X 144E 3911
acces_144_b_1_cat
acces_369_a_1_cat
600 1200 8.70 ... 18.23 221 ... 463 S3, S4 type 12.6 320 1401 1532
600 1200 8.70 ... 21.38 221 543 S3, S4 type 15.7 400 1401 1540
X
acces_260_a_2_cat
Description Reference
Shaft guide 1429 0000
Auxiliary Contacts
Use Electrical characteristics
Pre-break and signalling of positions 0 and I. A300 for 100 to 400 A.
A600 for 600 to 1200 A.
NO/NC contact for 100 ... 400 A
Rating (A) No. of AC Reference
100 ... 400 1st 2799 0021
100 ... 400 2nd 2799 0022
acces_076_a_1_cat
NO/NC contact for 100 ... 400 A
Rating (A) No. of AC Reference
100 ... 400 1st 2799 0121
100 ... 400 2nd 2699 0122
Auxiliary contact holder for 600 ... 1200 A
acces_045_a_1_cat
Rating (A) Type Reference
600 ... 1200 Holder 3999 0720(1)
600 ... 1200 NO 3999 0701
600 ... 1200 NC 3999 0702
(1) Please order the holder.
Terminal screens
Use
Top or bottom protection against direct contact with terminals or connection parts.
Rating (A) No. of poles Position Reference
100 ... 200 3P top 2798 3021
100 ... 200 3P bottom 2798 8021
100 ... 200 4P top / bottom 2798 4021
400 3P top 2798 3041
400 3P bottom 2798 8041
acces_079_a_1_cat
400 4P top / bottom 2798 4041
600 3P bottom 2798 3060(1)
600 4P bottom 2798 4060(1)
800 1200 3P bottom 2798 3120(1)
800 1200 4P bottom 2798 4120(1)
(1) Load side screen, the line side is included with the switch.
Terminal lugs
Use
Connection of bare copper cables onto the lugs (without lugs).
No wires Lugs per
Rating max (A) Wires range per lug kit Wires Reference
100 ... 200 6 - 300MCM 1 2 Cu / Al 3954 2020
100 ... 200 6 - 300MCM 1 3 Cu / Al 3954 3020
100 ... 200 6 - 300MCM 1 4 Cu / Al 3954 4020
400 2 - 600MCM 1 2 Cu / Al 3954 2040
400 2 - 600MCM 1 3 Cu / Al 3954 3040
400 2 - 600MCM 1 4 Cu / Al 3954 4040
400 2x (#6 - 350MCM) 2 2 Cu / Al 3954 2041
400 2x (#6 - 350MCM) 2 3 Cu / Al 3954 3041
ul_032_a
Characteristics
Characteristics according to UL98/CSA22.2#4
Connection terminals
Min. connection section / AWG #6 #6 2x #6 / #2 2x #2 4x #2 4x #2 4x #2
2x 350 /
Max. connection section / AWG 300MCM 300MCM 2x 600MCM 4x 600MCM 4x 600MCM 4x 600MCM
600MCM
Mechanical characteristics
Endurance (number of operating cycles) 10000 8000 6000 6000 3500 3500 3500
Operating torque (lbs.in/Nm) 88.5/10 88.5/10 128.3/14.5 327.5/37 442.5/50 442.5/50 442.5/50
Auxiliary contacts
Electrical characteristics A300 A300 A300 A600 A600 A600 A600
(1) 2 pole in series.
(2) 3 pole in series.
Connection
Min. Cu cable cross section (mm) 35 70 185 2 x 150 2 x 185 2 x 240
Min. Cu busbar section (mm) 2 x 30 x 5 2 x 40 x 5 2 x 50 x 5 2 x 60 x 5
J1 U Z
Y 1
R1
CA
V
K
AC
AA
N
sirco-ul_011_a_2_x_cat
R2
T AD 1. Terminal shrouds
F C
Overall Terminal
dimensions shrouds Switch body Switch mounting Connection
Rating J1 J1 M M
(A) Unit C AC AD F 3p. F 4p. H 3p. 4p. K 3p. 4p. N R1 R2 T U V W Y Z AA CA
in 3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.7 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6
100
mm 94.6 256 77.5 180 230 107 55 105 45.6 160 210 135 9 7 50 25 30 11 3.5 34.4 160 15
in 3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1,18 0,43 0,14 1,35 6,3 0,6
200
mm 94.6 256 77.5 180 230 107 55 105 45.6 160 210 135 9 7 50 25 30 11 3,5 34,4 160 15
in 4.92 16 4.15 9.05 11.4 6.53 2.95 5.31 2.65 8.26 10.6 7.67 0.35 0.27 2.56 1.77 1.97 0.43 0.2 2.08 10.2 0.8
400
mm 128 406 115 230 290 166 75 135 67,5 210 270 195 9 7 65 45 50 13 5 53 260 20
600 A
H M
Z J
0.51
13
Y
N1
X
AC
AA
N
sirco_107_d_1_x_cat
3.15
80
F
Terminal
shrouds Switch body Switch mounting Connection
Rating (A) Unit AC F 3p. F 4p. H J 3p. J 4p. M 3p. M 4p. N N1 AA Z
in 18.12 11 14.17 5.5 5 6.59 10.03 13.19 6.88 2.34 12.6 1.85
600
mm 460 280 360 140 127.5 167.5 255 335 175 59.5 320 47
H 1.57 M
40
Z J
0.78 0.78
0.43
20 20
11
N1
X
AC
N
N2
sirco_228_d_1_x_cat
8.85
225
4.72
120
F
sirco_267_b_1_x_cat
5.31
135
7.48
190
3.35
Mounting orientation 85
3/4 pole
sirco-ul_028_a_1_x_cat
S2 type
0 40
90
78 47
sircm-pv_006_b_1_gb_cat
I
28
125
37
45
600 to 1200 A
Front operation
Handle type Direction of operation Door drilling template
sircm-ul_007_b_1_gb_cat
78
I
28
28
70
44 37 31
600 to 1200 A
Front operation
Handle type Direction of operation Door drilling
S4 type
I
78
37
90
350
28
0
sircm-ul_006_a_1_gb_cat
47
40
60
2
1.49
1
1.3
35
4.7
38
51 0.53
13.46
0.45 2.8 0.63
49.30
1.94
sirco-ul_026_a_1_cat
sirco_115_b_1_x_cat
sirco_116_b_1_x_cat
31.75
1.25
1.12
28.6
0.25
11.13
0.44
6.35
1.8
46
2.87
73
Strong points
technology.
switches
sirco-ul_004_b_cat
Conformity to standards
SIRCO
SIRCO
PV
PV
References
3/4-pole load break switches
Bridging bars for
Rated voltage Direct operation Shaft for external
Rating (A) No. of poles Switch body External operation connecting poles
(VDC) handle handle
in series
600 3P 27DC 3011 S2 type 1 piece
100 A Black 200 mm 2709 0021
1000 4P 27DC 4011 1, 3R, 12 7.9 inches (100 to 200A)
600 3P 27DC 3021 142F 2111(1) 1400 1020 2 pieces
Red/Yellow 2x
250 A 1, 3R, 12 320 mm
1000 4P 27DC 4021 Black 2709 0025
142G 2111(1) 12.6 inches (250A)
2699 5052
Black 1400 1032
600 3P 27DC 3041 4, 4X
142D 2111(1) 400 mm 1 piece
400 A Red/Yellow 15.7 inches
1000 4P 27DC 4041 2709 0041
4, 4X 1400 1040(2)
142E 2111(1)
600 3P 27PV 3060 S3 type
Black 4, 4X
200 mm 1 piece
600 A 143D 3111(1)
1000 4P 27PV 4060 7.9 inches 2709 0061
Red/Yellow 4, 4X
143E 3111(1) 1401 1520
320 mm
750 3P 27DC 3081 Black S4 type 1 piece
800 A 12.6 inches
2799 7012 Black 2709 0081
1000 4P 27DC 4081 1401 1532
4, 4X 400 mm
750 3P 27DC 3121 144D 3111(1) 15.7 Inches
Red/Yellow 1 piece
1200 A 1401 1540(2)
1000 4P 27DC 4121 4, 4X 2709 0121
144E 3111(1)
750 3P 27DC 3162
1600 A V1 type 320 mm 2 pieces
1000 4P 27DC 4162
2799 7062 Black 3R, 12 12.6 inches 2x
750 3P 27DC 3201 2799 7145 4199 3018 2709 0121
2000 A
1000 4P 27DC 4201
(1) Defeatable handle.
(2) Shaft guide reference 1429 0000 is required for shaft length over 15.7 inches (400mm).
Accessories
External operation
Use Example
The door interlocked external operation handle The locking function of the enclosure in
acces_150_a_1_cat
includes a padlockable handle, a conversion kit the "ON" position will force the operator to
and must be combined with a shaft extension. safely disconnect and isolate the solar cell
acces_236_a_2_cat
In a combiner box, located close to the solar strings prior to any intervention. Opening the
cell strings, or located close to the inverter, we door when the switch is on "ON" position is
recommend to use a door interlocked external possible by defeating the locking function
handle for its safety features. using a tool (authorized persons only).The S2 type handle
interlocking function is restored when the
Reinforced S2 type handle
door is closed back.
Front operation I - 0, 3/4 poles
Nema degree of
Rating (A) Handle Handle colour Reference
protection
100 400 S2 type Black 1, 3R, 12 142F 2111(1)
100 400 S2 type Red/Yellow 1, 3R, 12 142G 2111(1)
100 400 S2 type Black 4, 4X 142D 2111(1)
100 400 S2 type Red/Yellow 4, 4X 142E 2111(1)
600 S3 type Black 4.4X 143D 3111(1)
600 S3 type Red/Yellow 4.4X 143E 3111
800 1200 S4 type Black 4, 4X 144D 3111(1)
800 1200 S4 type Red/Yellow 4, 4X 144E 3111(1)
1600 2000 V1 type Black 1, 3R, 12 2799 7145
acces_152_a_2_cat
(1)
Defeatable handle.
access_189_a
acces_166_a_2_cat
Accessories (continued)
Shaft for external handle
Use
acces_369_a_1_cat
Standard lengths: Other lengths: Please consult us.
- 7.9 in / 200 mm,
- 12.6 in / 320 mm,
- 15.7 in / 400 mm.
acces_144_b_1_cat
Dimension X Dimension Length Length
Rating (A) Handle Reference
(inches) Y (mm) (inches) (mm)
100 200 6 11.6 295 S2 type 7.9 200 1400 1020
100 200 6 16.3 415 S2 type 12.6 320 1400 1032
100 200 6 19.4 495 S2 type 15.7 400 1400 1040
400 8 12.9 203 328 S2 type 7.9 200 1400 1020
400 8 17.6 203 448 S2 type 12.6 320 1400 1032
400 8 20.7 203 528 S2 type 15.7 400 1400 1040
600 8.70 13.50 221 343 S3 type 7.9 200 1401 1520
600 8.70 18.23 221 463 S3 type 12.6 320 1401 1532
600 8.70 21.38 221 543 S3 type 15.7 400 1401 1540
acces_202_a_1_x_cat
800 1200 12 14.4 221 366 S4 type 7.9 200 1401 1520
800 1200 12 19.1 221 486 S4 type 12.6 320 1401 1532
800 1200 12 22.2 221 566 S4 type 15.7 400 1401 1540
2000 20 28.1 508 714 S5, V1 type 12.6 320 4199 3018
X
2000 20 39.4 508 794 S5, V1 type 15.7 400 4199 3019
Use Dimensions
For handles S2, S3 and S4. Increases the distance between the handle
grip and the door by 12 mm, for better
handling.
To be ordered
Colour Nema degree of protection Reference
in multiples of
Black 1, 3R, 12 10 1493 0000
acces_187_a_3_cat
Handle To be ordered
Handle Reference
colour in multiples of
Light grey S2, S3 type 50 1401 0001
Dark grey S2, S3 type 50 1401 0011
Light grey S4 type 50 1401 0031
Dark grey S4 type 50 1401 0041
Auxiliary contact
Use Electrical characteristics
Pre-break and signalling of positions 0 and I: A300.
- 1 to 2 NO/NC auxiliary contacts,
- 1 to 2 low level NO/NC auxiliary contacts.
acces_076_a_1_cat
NO/NC contact for 3/4 poles Low level NO/NC contact for 3/4 poles
Rating (A) Position AC Type Reference Rating (A) Position AC Type Reference
100 1200 1 contact NO/NC 2799 0021 100 1200 1 contact NO/NC 2799 0121
100 1200 2 contacts NO/NC 2799 0022 100 1200 2 contacts NO/NC 2799 0122
1600 2000 1 contact NO/NC 4159b 1600 2000 1 contact NO/NC 4159b
Terminal screen
Use
Top or bottom protection against direct contact with terminals or connection parts.
For 3/4 poles
acces_079_a_1_cat
Rating (A) No. of poles Operating principle Reference
100 250 3P top 2798 3021
100 250 3P bottom 2798 8021
100 250 4P top or bottom 2798 4021
400 3P top 2798 3041
400 3P bottom 2798 8041
400 4P top or bottom 2798 4041
600 3P top or bottom 2798 3060
600 4P top or bottom 2798 4060
800 1200 3P top or bottom 2798 3120
800 1200 4P top or bottom 2798 4120
1600 2000 3P top or bottom 2798 6122
1600 2000 4P top or bottom 2798 8122
Cage terminals
Use
Connection of bare copper cables onto the terminals (without lugs).
.OSHNM@KE@MNTSJHSENQQ@SHMFRNESN ENQBNMMDBSHMFRDUDQ@KB@AKDRSNSGDRVHSBG
Max. number
Rating max Type of
Numbrer and size of cables of connections Quantity Reference
(A) cable
per terminal
100 250 1 conductorr (#6-300MCM) 1 Cu / Al 2 lugs 3954 2020
ul_032_a
100 250 2 conductors (#4-2/0) 1 Cu / Al 2 lugs 3954 2025
400 1 conductor (#2-600MCM) 1 Cu / Al 2 lugs 3954 2040
400 2 conductors (#6-350MCM) 1 Cu / Al 2 lugs 3954 2041
600 2 conductors (#2-600MCM) 1 Cu / Al 2 lugs 3954 2060
800 1200 2 conductors (#2-600MCM) 2 Cu / Al 2 lugs 3954 2060
800 1200 2 conductors (#2-600MCM) 3(1) Cu / Al 3 lugs 3954 3060
1600 2000 2 conductors (#2-600MCM) 2(2) Cu / Al 2 lugs 3954 2060
1600 2000 2 conductors (#2-600MCM) 3(3) Cu / Al 3 lugs 3954 3060
(1) Order a fan out kit reference 2709 1203 for connecting 3 connectors per terminal (6 in total for the switch).
(2) 2 connectors per terminal with the connection kit 2729 1200.
(3) 3 connectors per terminal with the connection kits 2729 1201 and 2709 1202.
Accessories (continued)
Copper bars connection kits
Use Fig. 1
To allow connection between the two power terminals from a same
pole for 2000 A ratings. (Fig. 1, Fig. 2 and Fig. 3)
Fig. 3
acces_312_b_1_x_cat
Top or bottom flat connection
Quantity to order Number of
Rating (A) Figure Reference
per pole terminals
1600 2000 1 1 2 2729 1200
acces_314_b_1_x_cat
1600 2000 2 1 3 2729 1202
Fig.2
acces_313_b_1_x_cat
Quantity to order Number of
Rating (A) Figure Reference
per pole terminals
1600 2000 3 1 3 2729 1201
Characteristics
as per standards UL98/CSA22.4#4 and UL98B(6)
Rating (A) 100 A 250 A 400 A 600 A 800 A 1200 A 1600 A 2000 A
Connection terminals
Min. connection wire range/ AWG (2) #6 #6 2x#6 2x#2 4x#2 4x#2 4x#2 4x#2
Max. connection wire range/ AWG (2) 300MCM 300MCM 600MCM 2x 600MCM 6x 600MCM(5) 6x 600MCM(5) 6x 600MCM(5) 6x 600MCM(5)
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 6 000 6 000
Operating effort (lbs.in/Nm) 88.5/10 88.5/10 128.3/14.5 327.5/37 495.7/56 663.9/75 663.9/75 663.9/75
Auxiliary contact
Electrical characteristics A300 A300 A300 A300 A300 A300 A300 A300
Thermal current Ith at 40C 160 A 250 A 630 A 800 A 1000 A 1400 A 1400 A 2200 A
Rated insulation voltage Ui (V) 1 200 1 200 1 200 1 200
Rated impulse withstand voltage Uimp (kV) 12 12 12 12 12 12 12 12
Dimensions (in/mm)
100 to 400 A
M
J1 U Z
Y 1
R1
CA
V
K
AC
AA
N
sirco-ul_011_a_1_x_cat
R2
T AD
F C 1. Terminal shrouds
Overall Terminal
Switch body Switch mounting Connection
dimensions shrouds
Rating (A) Measurement
F F J1 J1 M M
F AC AD H K N R1 R1 T U V W Y Z AA AC
3p. 4p. 3p. 4p. 3p. 4p.
100 250 in 3.72 10.1 3.05 7.09 9.06 4.22 2.17 4.13 1.8 6.3 8.27 5.31 0.35 0.27 1.97 0.98 1.18 0.43 0.14 1.35 6.3 0.6
100 250 mm 94.6 256 77.5 180 230 107 55 105 45.6 160 210 135 9 7 50 25 30 11 3.5 34.4 160 15
400 in 4.92 16 4.51 9.05 11.4 6.53 2.95 5.31 2.65 8.26 10.6 7.6 0.35 0.27 2.56 1.77 1.97 0.43 0.2 2.08 10.2 0.8
400 mm 128 406 115 230 290 166 75 135 67.5 210 270 195 9 7 65 45 50 13 5 53 260 20
600 A
M AD
J 1 Z
U Y
W
CA
V
AC
AA
N
sirco-ul_005_c_1_x_cat
F 1. Terminal screens.
Terminal
Switch body Switch mounting Connection
Rating (A) Measurement shrouds
AC AD F 3p. F 4p. J 3p. J 4p. K M 3p. M 4p. N T U V W Y Z AA AC
600 in 18.12 5.5 11.02 14.17 5 6.59 2.34 10.04 13.19 6.88 3.15 1.97 2.38 0.41 0.28 1.83 12.64 0.82
600 mm 460 140 280 360 127.5 167.5 59.5 255 335 175 80 50 60.5 10.5 7 46.5 321 20.9
M Z 0.41
= = Y 10.5
U
V
13 / 330
= 0.28 / 7 =
23.78 / 604
1.10
28
= =
0
1.49
38
0.82
AA
21
1.02 1.49 1.02
90
sirco-ul_040_b_1_x_cat
0.35 26 38 26
9
I 3.54
X1 T T T X2 7.87 / 200 1.02 / 26 90
F 8.90 / 226
1600 to 2000 A
0.41
10.5
svr-ul_004_b_x_cat
13.5
1.49
38
343
0.82
21
3.54
90
11.85
301
4.92
125
11.34
9.84
250
288
11.85
301
S2 type
0 40
90
78 47
28
poign_013_a_1_gb_cat
125
37
45
600 A
Front operation
Handle type Direction of operation Door drilling
S3 type I
78
90
37
40
poign_035_a_1_gb_cat
210
47
28
61
S4 type
I
78
37
90
350
28
0
poign_036_a_1_gb_cat
47
40
60
1200 to 2000 A
Front operation
Handle type Direction of operation Door drilling
V1 type 50
I
4 6,5
poign_037_a_1_ca_cat
545
0
50
31
122
Jumpers (in/mm)
100 to 250 A 400 A
sirco-ul_009_a_1_x_cat
12.5 50 12.5 4
0.47 0.59
3.19
15
81
sirco-ul_008_a_1_x_cat
12
0.43
0.75
19
11
600 A 800 A
0.98 3.15 0.98
25 80 25
0.55
14
0.43
11
87.5
3.44
0.41
3.94
100
10.5
sirco-ul_048_b_1_x_cat
sirco-ul_047_a_1_x_cat
1.02 1.49
26 8.27 38 0.315
0.2 210 8
1.69
5 43
1200 to 2000 A
122.5
4.82
sirco-ul_049_b_1_x_cat
0.41
10.5
1.02 1.49
26 8.27 38 0.315
210 8 2.8
71
Mounting orientation
3/4 poles
sirco-ul_028_a_1_x_cat
1.3
35
4.7
16 0.27
0.45 7 2.8 0.63
1.52 11.6 71.5 15.88
1.26
32
38.8
sirco-ul_038_a_1_x_cat
sirco-ul_010_a_1_x_cat
sirco_115_b_1_x_cat
1.12
28.6
11.13
0.79
0.44
0.2
1.8
20
46
5
51 0.53
13.46
49.30
1.94
0.40
10.2
3.15
80
1.19
30.23
31.75
sirco-ul_026_b_1_cat
sirco_116_b_1_x_cat
1.25
0.25
6.35
2.87
73
2 x 350MCM 2 x 600MCM
Strong points
technology.
switches
Conformity to standards
sirco-ul_023_a_1_cat
Function
It is possible to operate on load two switches Easier connection and integration.
with one handle. Higher voltage: by connecting the two
Space saving: the overall footprint is similar to switches in series it is possible to switch on
the footprint of a standard 3 or 4 pole device. load higher voltage than 1000 VDC.
Thus providing significant space saving Double the rating: by connecting the two
opportunities within the overall assembly switches in parallel on the outgoing side.
and specifically compared to using separate
switches.
General characteristics
q Patended switching technology. q Suitable for use in accordance with
q Positive break indication. NEC Art 690 edition 2011.
q Up to 1000 VDC according to q Up to 1500VDC according to IEC 60947-3.
UL98B/CSA C22.2#4.
Switch 1
Switch 2
q The double stack disconnect from SOCOMEC interlocks mechanically 2 disconnects 3 or 4 poles.
With one handle the user can operate on load both disconnects synchronously.
sirco-ul_044_a_1_gb_cat
Switch 1
I = Switch 1+ Switch 2
Switch 2
q As both disconnects are operating synchronously the user can link the output of each device.
sirco-ul_045_a_1_gb_cat
q Following the Kirchhoffs law "At any node (junction) in an electrical circuit, the sum of currents
flowing into that node is equal to the sum of currents flowing out of that node" or in our case
Iswitch1 + Iswitch2 = Ioutput.
- + q R@MDW@LOKD@TRDQBNTKCCHRBNMMDBS VHSG@CNTAKD
+ q This solution really reduces the footprint of the disconnect.
LOAD /
CHARG
E / CAR
GA
Switch 1+2
q Following the second Kirchhoffs law "The principle of conservation of energy implies that the
sirco-ul_046_a_1_gb_cat
directed sum of the electrical potential differences (voltage) around any closed network is zero".
q On the schematic above this would mean that Vswitch1 + Vswitch2 = Vtotal.
q And this implies that more poles are in series, higher is the achievable voltage.
- + q Following this principle SOCOMEC created a disconnect with 8 poles in series which allows
SGDTRDQSNCHRBNMMDBS.-+. #5#"
+ q RUNKS@FDRGHFGDQSG@M5#"@QDMNSQDBNFMHYDCAX4+2.".,$"RDKEBDQSHEHDCSGHR
LOAD /
CHARG
E / CAR
configuration in its laboratory in France.
GA
References
6 & 8 poles switches
Max Number No. of Shaft for external Jumpers for connecting
Rating (A) of circuits Max Breaking Voltage (VDC) poles Switch body External handle handle poles in series
S2 type
2 2 x 600 VDC 6P 27DC 6011 Black 200 mm
1 piece
100 A 1, 3R, 12 7.9 inches
2709 0021
Frame 2x4 142F 2111(1) 1400 1020 (100 to 200 A)
2 2 x 1000 VDC or 1x 1500 VDC 8P 27DC 8011 Red/Yellow
1, 3R, 12 320 mm
142G 2111(1) 12.6 inches
Black 1400 1032
2 2 x 600 VDC 6P 27DC 6021 4, 4X
2 pieces
250 A 142D 2111(1) 400 mm /
Frame 2x4 Red/Yellow 15.7 inches 2 x 2709 0021
4, 4X 1400 1040(2) (250 A)
2 2 x 1000 VDC or 1x 1500 VDC 8P 27DC 8021
142E 2111(1)
S3 type 200 mm
2 2 x 600 VDC 6P 27DC 6041 Black 4, 4X 7.9 inches
(1)
400 A 143D 3111 1401 1520 1 piece
Frame 2x5 Red/Yellow 320 mm 2709 0041
2 2 x 1000 VDC or 1x 1500 VDC 8P 27DC 8041 4, 4X 12.6 inches
143E 3111(1) 1401 1532
Accessories
S type handle Raiser
Use Dimensions
S type handle raiser. Adds 12 mm to the depth.
Handle raiser for S1 to S4 handles.
acces_187_a_3_cat
To be ordered
Colour Nema degree of protection in multiples of Reference
Black 1, 3R, 12 10 1493 0000
Accessories
External handle
Use Opening the door when the switch is on
The interlocking function of the front "ON" position is possible by defeating
external handle prevents the user from the locking function with the use of a tool
opening the door of the enclosure when the (authorized persons only).
acces_150_a_1_cat
switch is in the "ON" position (if the handle The interlocking function is restored when
is door mounted S-type handles only). the door is closed back.
acces_236_a_2_cat
Front operation I - 0, 6/8 poles
acces_166_a_2_cat
Nema degree of
Rating (A) Handle Handle colour protection Reference S2 type handle
100 250 S2 type Black 1, 3R, 12 142F 2111(1)
Reinforced S2 type handle
100 250 S2 type Red/Yellow 1, 3R, 12 142G 2111(1)
100 250 S2 type Black 4, 4X 142D 2111(1)
100 250 S2 type Red/Yellow 4, 4X 142E 2111(1)
400 S3 type Black 4, 4X 143D 3111(1) S3 type handle
400 S3 type Red/Yellow 4, 4X 143E 3111(1)
600 1000 S5 Type Black 1, 3R, 12 145F 8113(1)
600 1000 V1 type Black 1, 3R, 12 2799 7145(1)
(1) Defeatable handle.
acces_286_a_2_cat
acces_152_a_2_cat
(1) Locking bracket in metal.
(2) Defeatable handle.
acces_198_a_3_cat
Handle To be ordered
colour Handle by multiples of Reference
Light grey S1 to S3 type 50 1401 0001
Dark grey S1 to S3 type 50 1401 0011
Light grey S4 type 50 1401 0031
Dark grey S4 type 50 1401 0041
100 200 12 22.1 305 562 S2 type 15.7 400 1400 1040
400 16 18.4 406 467 S3 type 7.9 200 1401 1520
400 16 23.1 406 587 S3 type 12.6 320 1401 1532
400 16 26.3 406 667 S3 type 15.7 400 1401 1540
600 1000 20 28.1 508 714 V1/S5 type 12.6 320 4199 3018
600 1000 20 31.3 508 794 V1/S5 type 15.7 400 4199 3019 X
Accessories (continued)
Shaft guide for external handle
Use
To guide the detachable external control shaft in the handle.
This accessory enables handle to engage shaft with a misalignment of up to 15 mm.
Required for a shaft lenght over 320 mm.
Description Reference
Shaft guide for S1 to S4 type handles 1429 0000
Auxiliary contact
Use Electrical characteristics
Pre-break and signalling of positions 0 and I: A300.
- 1 to 2 NO/NC auxiliary contacts,
- 1 to 2 low level NO/NC auxiliary contacts.
NO/NC contact for 6/8 poles
acces_076_a_1_cat
Rating (A) Position AC Type Reference
100 1000 NO/NC 4159 0021
Low level NO/NC contact for 6/8 poles
Rating (A) Position AC Type Reference
100 1000 1st contact NO/NC 4159 0022
Terminal screen
Use
Top or bottom protection against direct contact with terminals or connection parts.
For 6/8 poles
Rating (A) No. of poles Position Reference
100 200 6P top and bottom 4158 3021
acces_079_a_1_cat
100 200 8P top and bottom 4158 4021
400 6P top or bottom 4158 3041(1)
400 8P top or bottom 4158 4041(1)
600 6P top or bottom 1609 3063(1)
600 8P top or bottom 1609 4063(1)
800 1000 6P top or bottom 2798 6120
800 1000 8P top or bottom 2798 8120
(1) Please order 2 reference sfor line and load protection.
Terminal lugs
Use
Connection of bare copper cables onto the terminals (without lugs).
Number of lugs Type of
Rating max (A) Type of luge per terminal cable Package Reference
100 250 1 conductor (#6-300MCM) 1 Cu / Al 2 lugs 3954 2020
100 250 2 conductors (#4-2/0) 1 Cu / Al 2 lugs 3954 2025
400 1 conductor (#2-600MCM) 1 Cu / Al 2 lugs 3954 2040
400 2 conductors (#6-350MCM) 1 Cu / Al 2 lugs 3954 2041
ul_032_a
3N@KKNVBNMMDBSHNMADSVDDMSGDSVNONVDQSDQLHM@KREQNL@R@LDONKDENQSN
ratings (Fig. 1, Fig. 2 and Fig. 3).
Fig. 3
Top or bottom flat connection
Rating (A) Quantity to order per switch Nb lug capacity Reference
800...1000 Fig. 1 1 2 2729 1200 Fig. 2
800...1000 Fig. 2 1 3 2729 1202
acces_313_b_1_x_cat
acces_314_b_1_x_cat
sirco-ul_012_a_1_gb_cat
Connection diagrams:
(1) Other connections: refer to mounting instructions.
Characteristics
Characteristics according UL98/CSA22.4#4 and UL98B
Rating (A) 100 A 250 A 400 A 600 A 800 A 1000 A
Connection terminals
Min. connection section / AWG(2) #6 #6 2x #6 2x #2 4x #2 4x #2
Max. connection section / AWG(2) 300MCM 300MCM 600MCM 2x 600 6x 600MCM(4) 6x 600MCM(4)
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 6 000 6 000
Operating torque (lbs.in/Nm) 88.5/10 88.5/10 128.3/14.5 327.5/37 495.7/56 495.7/56
Auxiliary contacts
Electrical characteristics A300 A300 A300 A300 A300 A300
(1) 50 ms without fuse. (3) Increased endurances: Please consult us.
(2) AWG : dimensions of the American cable. (4) max 6x 600MCM with spreader 2729 1203.
0.53
13.3
0.98 132.5
1.37 6.30 (3P) - 8.26 (4P) 1.51
25
35 160 (3P) - 210 (4P) 38.5
1.18
30
0.43
11
132.5
5.21
2.67
68
0.35
6.30
5.31
1.35
0.29
160
7.5
0.27
sirco-ul_042_b_1_x_cat
132.5
5.21
132.5
1.97 5.21 6.93
50 176
9.60 (3P) - 11.57 (4P)
244 (3P) - 294 (4P)
400 A
Z1
Z
T T Y
Y
U
CA
W
R1
V
I
sirco-ul_016_a_1_x_cat
AC
BA
AA
0
N
R2
X
M AD
K C
1. Terminal shrouds.
A. S2 type handle.
Overall Terminal
Rating dimensions shrouds Case Switch mounting Connection
(A) Mesurement C AC AD K 3p. K 4p. M 3p. M 4p. N R1 R2 T U V W X Y Z Z1 AA BA AC
400 in 10.39 15.75 9.72 9.61 11.97 8.27 10.63 7.68 0.35 0.27 2.56 1.77 1.97 0.50 0.43 0.20 2.07 7.48 10.24 8.66 0.79
400 mm 264 400 247 244 304 210 270 195 9 7 65 45 50 12.7 11 5 52.6 190 260 220 20
600 A
15.19 (3P) - 18.34 (4P)
386 (3P) - 466 (4P)
3.15 13.66
80 347
9.09
9.05
231
230
13.38
340
9.84
250
sirco-ul_017_a_1_x_cat
1.96
4.92
125
50
0.98
9.09
231
25
1.12 0.82
28.5 21
2.61
66.5
2.02 Fix 10.04 (3P) - 13.18 (4P) 9.98
51.5 Fix 255 (3P) - 335 (4P) 253.5
14.56
370
0.41
10.5
800 to 1000 A
0.41
10.5
13.5
1.49
38
343
0.82
21
3.54
90
11.85
301
4.92
125
sirco-ul_043_b_1_x_cat
11.34
9.84
250
288
11.85
301
0.55
14
0.47 0.59
15
sirco-ul_008_a_1_x_cat
sirco-ul_009_a_1_x_cat
sirco-ul_047_a_1_x_cat
3.19
81
0.43
12
11
3.94
100
0.43
11
0.75
19
0.89 2.56 0.89 0.2
22.5 65 22.5 5
0.2
5
800 A 1000 A
122.5
4.82
87.5
3.44
0.41
10.5 0.41
sirco-ul_048_b_1_x_cat
sirco-ul_049_b_1_x_cat
10.5
1.02 1.49
26 8.27 38 0.315
210 8 1.02 1.49
1.69 26 38 0.315
8.27
43 210 8 2.8
71
1.3
35
4.7
0.63 37.5
25
1
16 0.27
7 2.8 0.63
0.45 71.5 15.88
1.26
1.52 11.6
32
38.8
sirco_115_b_1_x_cat
sirco-ul_010_a_1_x_cat
sirco-ul_038_a_1_x_cat
11.13
0.44
1.12
28.6
1.8
46
0.79
0.2
20
2
38
51 0.53
13.46
49.30
1.94
0.40
10.2
sirco-ul_029_a_1_x_cat
3.15
sirco-ul_026_b_1_cat
sirco_116_b_1_x_cat
80
1.19
30.23
31.75
1.25
0.25
6.35
2.87
73
2 x 350MCM
6/8 pole - 600 A
2x 600MCM
sirco-ul_030_a_1_x_cat
S2 type I
3.07
1.46
90
78
37
1.57
40
0
sirco-ul_032_a_1_gb_cat
4.92
125
1.77
45 1.10 4 0.27
47
28
400 A
Front operation
Handle type Direction of operation Door drilling
S3 type I
78
90
37
40
210
poign_035_a_1_gb_cat
47
28
61
600 to 1000 A
Front operation
Handle type Direction of operation Door drilling
V1 type 1.97
50
I
4 0.25
4 6.5
21.46
545
poign_037_a_1_us_cat
0
1.97
50
1.22
4.80 31
122
Front operation
Handle type Direction of operation Door drilling
S5 type
with V Escutcheon 1.97
50
I
4 0.25
90 4 6.50
1.97
50
0
19.6
498
1.22
poign_020_a_1_us_cat
31
2.80
71
4
102
Strong points
Conformity to standards(1)
> UL508,
Guide NRNT,
sirco_123_a_2_cat
File E224992
> IEC 60947-3
Customised solutions
SIRCO
3 pole
> Please consult us.
Function
The TVSS Surge Switch is an extremely compact, high performance, manually operated,
non-fused switch. It is specifically designed to withstand the high surge current of 200 kA
VHSG@MWRV@UDENQLRDDMHMSNC@XRSQ@MRHDMSUNKS@FD2TQFD/QNSDBSHUD#DUHBD2/#
applications. Socomec Surge Switch uses a unique contact design that actually clamp contacts
tighter during a surge.
General characteristics
q J RRGNBJV@UDVHSGRS@MC
q Rated 100 A 600 VAC UL508 general use.
q High electrical and mechanical endurance.
L1
L2
L3
L4
Surge switch
sirco-ul_021_a_1_x_cat
TVSS
References
TVSS SURGE SWITCH - Front operation - 3/4 pole
Rating (A) No. of poles Switch body Direct handle Door interlocked external Shaft for external handle Terminal shrouds
S1 type
Black
141F 2111
/ 2700 3017 200 mm
S1 type
1400 1020
Black Red/Yellow /
R 2699 5042 141G 2111 2694 3014(1)
320 mm
200 KA
1400 1032
600 VAC Red S1 type /
2699 5043 Black 2694 4014(1)
400 mm
141D 2111
/ 2700 4017 1400 1040
S1 type
Red/Yellow
141E 2111
(1) Top or bottom.
UL characteristics
UL 508 100 A 600 VAC General use
#HLDMRHNMRHMLL
3 pole 4 pole
3.62
3.62
92
92
0.83 0.83
21 1.77 2.95 21 2.95 2.95
1.38 45 75 0.35 1.37 0.79 75 75
0.35
3.5 0.79 9 3.5 20 9
20 2.16
2.16
5.5
5.5
4.53
3.35 115
4.52
0.1
3.35 115
2.5
2.56
65
85
0.39
85
10
0.4
10
sirco-ul_020_a_1_gb_cat
sirco-ul_019_a_1_gb_cat
0.39 0.39
2.56 0.79 2.56 10 0.78
65 10 1.42 20 65 1.42 20
1.1 36 0.86 36
28 22 6.69
5.51
140 170
Despite already offering a wide range of load break switches, SOCOMEC also
manufactures specific products suitable for all your requirements. Some of these
switches
products can be seen on these two pages, however this list does not include them all.
Please, feel free to consult us.
q 240 kA peak.
Multipolar SIRCO
SOCOMEC can provide switches up to 16 poles.
sirco_256_a_1_cat
12 pole SIRCO.
sirco_338_a_1_x_cat
sirco_363_a_2_cat
References
Rating (A) 40 63 80 100 125 160
Power supply
No. of poles Reference Reference Reference Reference Reference Reference
voltage
4P 230 VAC 1923 4004 1923 4006 1923 4008 1923 4010 1923 4012 1923 4016
References
160 to 400 A
FUSOMAT Contact us
SIDERMAT
FUSOMAT combination
250 to 1250 A 1600 to 1800 A
p. 238 p. 230
Fuses
Distribution protection Semiconductor protection
BS88 NFC/DIN
gG fuses gG fuses UR fuses
2 to 1250 A 0.16 to 1250 A 10 to 2000 A
p. 272 p. 278 p. 224
Motor protection
new
Fuse base
160 to 2500 A RM - RMS p. 604
p. 266 p. 262
6SHFLFSURGXFWV
Photovoltaic applications 6DVHKKGDKOXNTjMCSGD
right solution for your
application.
new n ew n ew Please feel free to consult us.
SOCOMEC has always promoted the benefits of fuses for both personal and equipment Useful information
safety. Fuse protection offers lots of benefits compared to circuit breakers in a large
number of applications. q"NMSQNKKDCAXSGD'5+5SQ@MRENQLDQ
Fuse switches provide a guarantee of reliable breaking and protection from power sensor, the fuse breaker switches
distribution to motor protection. Summary of the main benefits: with tripping function are the best
way of ensuring its general breaking
q Significant limitation of short circuits q Simplified discrimination and protection functions.
The thermal and mechanical effects Fuses allow total discrimination, regardless
generated during a short circuit can be of the short circuit level. This is ensured as q/QNSDBSHNMVHSGGHFGRODDC41
considerable. The speed at which a fuse soon as the ratio of ratings between the fuses is the only way to effectively
can cut out means it offers a much greater upstream and downstream fuse is at least protect the semiconductors used in
limitation of the short circuit current than 1:6. This characteristic guarantees perfect electronic equipment (variable speed
provided by circuit breaker technology continuity of the energy supplied drives, etc.) against short circuits.
(see fig. 1). (see an example in fig. 2).
ms
Mini x 1.6
fuser_641_b
Time (s)
100 A 160 A
fuser_493_c_gb
appli_563_a
Current
With over 90 years' experience, SOCOMEC offers a range of switches and components for Additional products
building a complete fuse protection solution. Our partnership also brings you additional benefits:
We also offer you a large range of
devices for electronically guaranteeing
personal and equipment safety
(differential protection, protection against
A responsive commercial A wide voltage surges).
network range
See our section on "Electronic
Our teams of engineers have built their Whatever your area of activity (industry, protection", page 508.
reputation on a reassuring closeness, data centre, photovoltaics, etc.), you'll find
specialist expertise and a commitment to the solution to your electrical protection
listening. requirements in this product family.
High-quality Customised
products solutions
SOCOMEC is renowned among its customers Are your requirements outside
sgys_076_a_1_cat
for the reliability of its fuse solutions. of the standard offering? As a specialist
resys_081_a
manufacturer, we can adapt our devices to
suit your specific requirements. Get in touch
with us or your usual contact to discuss your
options.
We're certain you'll find the answers to your questions about electrical protection on the Profuse
International website: www.profuseinternational.com
The site includes a detailed presentation of the customer benefits of fuse technology:
q4RDQR@EDSX
flcd-url_051_a
q1DKH@AKDHMRS@KK@SHNMR
q"NRSR@UHMFR
q$MUHQNMLDMS@KKXEQHDMCKXRNKTSHNM
INTERNATIONAL
make a smart choice for your electrical protection
application? operation?
Industry
new
FUSERBLOC FUSERBLOC SIDERMAT RM - RMS Fuse bases Industrial fuses Industrial fuses
BS88 UL combination & BS88 NFC/DIN
NFC/DIN FUSOMAT
20 to 1250 A 30 to 800 A 250 to 1800 A 32 to 100 A 160 to 2500 A 0,16 to 1250 A 2 to 1250 A
p. 188 p. 248 p. 230 - 238 p. 262 p. 266 p. 272 p. 278
Applications
Transformer output
Distribution panels
Main switchboards
Cable ducting
Motor circuits
Semiconductor protection
Photovoltaic installations
Operation
Manual
Trippable
Position of direct operation handle
Front
Side XSWRb$
Panel mounting XSWRb$ XSWRb$
Position of external operation handle
Front
Right side XSWRb$
Left side
Centred operation Please consult us Please consult us
Indication of breaking
Positive break indication
Visible contacts
Fuse
NFC/DIN
BS
UL
Other
Positive break
Which handle Which type of
indication or
location? fuse?
visible breaking?
Power electronics
Photovoltaic
(variable speed drives, inverters)
n ew new new
50 to 1250 A 32 to 50 A 32 to 600 A
p. 224 p. 288 p. 298 p. 304 p. 306
FUSERBLOC
630 to 1250 A
Strong points
fuser_539_a_1_cat
A complete range.
q Whether it is 3 pole + switched neutral or q From 32 to 400 A, the FUSERBLOC is q From 630 to 1250 A, the FUSERBLOC
3 pole + solid neutral, the FUSERBLOC available in 2, 3 or 4 poles with direct right allows direct and external front left or
20 to 32 A with direct front operation side operation. right side operation in 2, 3 or 4 poles.
and external operation is the best suited
solution in compact design.
fuser_705_a_1_cat
fuser_706_a_2_cat
fuser_704_a_1_cat
q With external operation, it is possible to q For ratings 20 to 400 A, the flat mounting q Maintenance of outputs from the DC common
operate the device in 3 ways: kit provides a compact solution ideally bus. The FUSERBLOC LMDC is the most
- Front operation suited to withdrawable applications. compact solution and the most economical
- Right side operation for your maintenance requirements (please
consult us).
- Left side operation.
fuser_702_a_2_cat
fuser-lm_002_a
fuser_703_a_1_cat
References
BS 88 - External front and side operation - 20 to 160 A
TEST Changeover
Rating (A) Reference External External Shaft Integrated
Number of Reference External external Terminal U type
Fuse size Changeover front right side extensions solid
poles Switch I-0 front handle front handle shrouds(3) A/C (2)
Frame size I - 0 - II handle I-0 handle I -0 for handle neutral link
I-0 TEST I - 0 - II
2P 3841 2016
160 A
B1-B2 3P 3841 3016 3880 3016
14
4P 3841 6016 3880 6016
(1) Standard.
(2) 4 auxiliary contacts as standard without additional contact holder.
(3) Top/bottom.
(4) For fuse size A4: max diameter 31 mm.
TEST Changeover
Rating (A) Reference External External Shaft Integrated
Number of Reference External external Terminal U type
Fuse size Changeover front right side extensions solid
poles Switch I-0 front handle front handle shrouds(3) A/C (2)
Frame size I - 0 - II handle I-0 handle I -0 for handle neutral link
I-0 TEST I - 0 - II
2P 3841 2019 2P
3998 2016
CD 200 A
3P
A3-A4 (5) 3P 3841 3019 3880 3019 3829 9320
3998 3016
13 A
4P
4P 3841 6019 3880 6019 3998 4016
2P 3841 2021
200 A
B1-B2 3P 3841 3021 3880 3021
15
4P 3841 6021 3880 6021
Black Black Black Black 3829 9325
S2 type S2 type S2 type S2 type
2P 3841 2024 IP55 IP65 IP55 IP55
250 A 1421 2111(1) 1423 2115(1) 1425 2111(1) 1421 2113(1)
320 mm
B1-B2-B3 3P 3841 3024 3880 3024
1400 1032
15 Red/Yellow Red/Yellow Red/Yellow Red/Yellow 2P
4P 3841 6024 3880 6024 S2 type S2 type S2 type S2 type 3998 2025
IP65 IP65 IP65 IP65 3P
1424 2111 1424 2115 1428 2111 1424 2113 3998 3025
2P 3841 2032 4P
315 A 3998 4025
B1-B2-B3 3P 3841 3032 3880 3032
1 contact
16
NO
4P 3841 6032 3880 6032 3999 0701
3829 9339
2P 3841 2038 1 contact
400 A NC
B1-B2- 3999 0702
3P 3841 3038
B3-B4
16
4P 3841 6038
2P 3821 2063
630 A
Black
C1-C2 3P 3821 3063
S3 type
17 2P
IP65
4P 3821 6063 3898 2080
1433 3111(1)
Black 3P
3829 9308
S3 type 3898 3080
2P 3821 2080 Red/Yellow
IP65 4P
S3 type
800 A 1437 3111(1) 3898 4080
IP65 320 mm
C1-C2-C3 3P 3821 3080
1434 3111 1400 1232
17 Red/Yellow
4P 3821 6080 S3 type
IP65
1438 3111
2P 3821 2120 3898 2120
Black
1250 A
S4 type
D1 3P 3821 3120 3898 3120 3829 9312
IP65
18
1443 3111(1)
4P 3821 6120 3898 4120
(1) Standard.
(2) 4 auxiliary contacts as standard without additional contact holder.
(3) Top/bottom.
(4) 8 AC as standard without support (the support is for 8 additional auxiliary contacts).
(5) For fuse size A4: max diameter 31mm
References (continued)
BS 88 - Direct operation - 20 to 160 A
Side direct
Rating (A) Reference Reference Handle key
Number of handle Direct front Auxiliary Terminal Cage
Fuse size Side direct Direct front interlocking
poles operation handle contacts shrouds(3) terminals
Frame size operation operation accessories(2)
switch
3P 3641 3000
20 A
3 P + switched 1 contact
A1 3641 4000
neutral NO/NC
0
3 P + solid A-type
3641 5000 3999 0001(1)
neutral Black
3629 4012
3P 3641 3001 2 contacts
NO/NC
CD 32 A
3 P + switched A-type
A1 3641 4001
neutral 3999 0002(1)
0
3 P + solid
3641 5001
neutral
Standard Standard
2P 3625 2003 consult us
32 A
A1 3P 3625 3003 consult us
1
4P 3625 6003 consult us
Black
3629 7903
3629 7900
2P 3625 2006 consult us
63 A
A2-A3 3P 3625 3006 consult us
2
4P 3625 6006 consult us
Side direct
Rating (A) Reference Reference Handle key
Number of handle Direct front Auxiliary Terminal Cage
Fuse size Side direct Direct front interlocking
poles operation handle contacts shrouds(3) terminals
Frame size operation operation accessories(2)
switch
2P 3625 2019 consult us
CD 200 A
A3-A4 (4) 3P 3625 3019 consult us 2P
13 A 3998 2016 3P
4P 3625 6019 consult us 3P 5400 3016
2P 3625 2021 consult us 3998 3016 4P
200 A 4P 5400 4016
B1-B2 3P 3625 3021 consult us 3998 4016
5 1 contact
4P 3625 6021 consult us NO/NC
A-type
2P 3625 2024 consult us 3P
250 A Black 3999 0021(1)
5400 3025
B1-B2-B3 3P 3625 3024 consult us 3629 7901 consult us 3629 7913
4P
5 2 contacts
4P 3625 6024 consult us 5400 4025
NO/NC
A-type 2P
2P 3625 2032 consult us
315 A 3999 0022(1) 3998 2025
B1-B2-B3 3P 3625 3032 consult us 3P
6 3998 3025 3P
4P 3625 6032 consult us 4P 5400 3040
2P 3625 2039 consult us 3998 4025 4P
400 A 5400 4040
B1-B2-B3-B4 3P 3625 3039 consult us
6
4P 3625 6039 consult us
(1) Max. 2 contacts.
(2) Lock not included.
(3) Top/bottom.
(4) For fuse size A4: max diameter 31 mm.
Side direct
Rating (A) Reference Reference Handle key
Number of handle Direct front Auxiliary Terminal Cage
Fuse size Side direct Direct front interlocking
poles operation handle contacts shrouds(3) terminals
Frame size operation operation accessories(2)
switch
References
NFC and DIN - External front and right side operation - 25 to 125 A
Rating (A) / External TEST External Changeover Shaft for Integrated
Switch Changeover Auxiliary Terminal
Fuse / No. of poles front external front right side external front external solid neutral
I-0-TEST switch I-0-II contacts(2) shrouds(1)
Frame size handle handle handle handle handle link
2P 3831 2005
50 A S1 type S1 type
14 x 51 3P 3831 3005(1) 3870 3005
11 Black Black
4P 3831 6005(1) 3870 6005 IP65 IP65
1411 2111 1413 2115 Standard
2P 3831 2006
63 A Red/Yellow Red/Yellow
00C 3P 3831 3006(1) 3870 3006 IP65 IP65
12 1414 2111 1414 2115
4P 3831 6006(1) 3870 6006
2P 3831 2010
U-type
100 A
320 mm
22 x 58 3P 3831 3010(1) 3870 3010 (2)
1400 1032 1 contact
13
3999 0600
4P 3831 6010(1) 3870 6010 S2 type S2 type S2 type S2 type
2P
2P 3831 2011 Black Black Black Black
IP65 IP55
3998 2016
125 A IP55 IP55
3P
22 x 58 3P 3831 3011 3870 3010 1421 2111 1423 2115 14252111 1421 2113 3829 9310
3998 3016
13
4P
4P 3831 6011 3870 6010 Red/Yellow Red/Yellow Red/Yellow Red/Yellow
3998 4016
IP65 IP65 IP65 IP65
2P 3831 2012 1424 2111 1424 2115 1428 2111 1424 2113
125 A
00 3P 3831 3012 3870 3011
13
4P 3831 6012 3870 6011
(1) Available enclosed (see page "Enclosed fuse switches" page XXX).
(2) Top/bottom.
(3) Maximum 4 contacts.
NFC and DIN - External front and right side operation - 160 to 1250 A
Rating (A) / TEST External Changeover Shaft for Integrated
No. of Changeover External Auxiliary Terminal
Fuse / Switch I-0 external front right side external external solid neutral
poles switch I-0-II front handle contacts shrouds(2)
Frame size handle handle front handle handle link
2P 3831 2015
160 A
00 3P 3831 3015 3870 3015 2P
13 U-type 3998 2016
4P 3831 6015 3870 6015 3P
3829 9320
2P 3831 2016 1 contact 3998 3016
160 A S2 type S2 type S2 type S2 type 3999 0600 (3)
4P
0 3P 3831 3016(1) 3870 3016 3998 4016
14 Black Black Black Black
4P 3831 6016(1) 3870 6016 IP55 IP65 IP55 IP55
320 mm
1421 2111 1423 2115 1425 2111 1421 2113
2P 3831 2024 1400 1032
250 A Red/Yellow Red/Yellow Red/Yellow Red/Yellow
1 3P 3831 3024(1) 3870 3024 IP65 IP65 IP65 IP65 2P 3829 9325
15 1424 2111 1424 2115 1428 2111 1424 2113 U-type 3998 2025
4P 3831 6024(1) 3870 6024 3P
2P 3831 2039 1 contact 3998 3025
(4)
400 A 3999 0600 4P
2 3P 3831 3039(1) 3870 3039 3998 4025 3829 9339
16
(1)
4P 3831 6039 3870 6039
2P 3811 2063 S3 type
630 A
3 3P 3811 3063(1) 2P
17 Black
IP65
3898 2080
4P 3811 6063(1) 3P
1433 3111 3829 9308
2P 3811 2080 3898 3080
800 A S3 type 4P
Red/Yellow
3 3P 3811 3080 3898 4080
IP65 Black
17 1434 3111
4P 3811 6080 IP65
320 mm
1437 3111
2P 3811 2081 1400 1232
800 A S4 type
Red/Yellow
4 3P 3811 3081 IP65 2P
18 Black
IP65 1438 3111 3898 2120
4P 3811 6081 3P
1443 3111 3829 9312
2P 3811 2120 3898 3120
1250 A 4P
Red/Yellow
4 3P 3811 3120 3898 4120
IP65
18 1444 3111
4P 3811 6120
(1) Available enclosed (see "Enclosed fuse switches" page XXX).
(2) Top/bottom.
(3) Maximum 4 contacts.
(4) Maximum 8 contacts.
References (continued)
NFC and DIN - Direct operation - 25 to 125 A
Rating (A) Lock for fuse Handle key
Direct side Direct front Auxiliary Terminal Cage
Fuse size No. of poles Direct handle protection interlocking
operation operation contacts shrouds terminals
Frame size cover accessories(6)
3P 3631 3002
25 A
3 P + switched
10 x 38 3631 4002
neutral
0
3 P + solid
3631 5002
neutral
A-type
3P 3631 3003 1 contact
NO/NC
CD 32 A 3999 0001(3)
3 P + switched Black
10 x 38 3631 4003 (1)(2)
neutral 3629 4012
0 A-type
3 P + solid 2 contacts
3631 5003 NO/NC Standard
neutral
3999 0002(3)
3P 3631 3004
Standard Standard
32 A
3 P + switched
14 x 51 3631 4004
neutral
0
3 P + solid
3631 5004
neutral
Rating (A)
Direct side and front
Fuse size No. of poles Direct front handle Direct side handle Auxiliary contacts Terminal shrouds
operation
Frame size
2P 3811 2063
630 A
3 3P 3811 3063 2P
17 3898 2080(3)
4P 3811 6063
Black 3P
3899 6011(1)(2) 3898 3080(3)
2P 3811 2080
800 A 4P
3 3P 3811 3080 U-type 3898 4080(3)
17
4P 3811 6080 1 contact NO
Black
3999 0701(4)
3899 7911
2P 3811 2081
800 A 1 contact NC
4 3P 3811 3081 3999 0702(4) 2P
18 3898 2120(3)
4P 3811 6081
Black 3P
3899 7011(1)(2) 3898 3120(3)
2P 3811 2120
1250 A 4P
4 3P 3811 3120 3898 4120(3)
18
4P 3811 6120
Accessories
Direct operation handle
For front operation
Rating (A) Frame size Figure no. Handle colour Reference
20 ... 32 0 1 Black 3629 4012
acces_147_a_2_cat
20 ... 32 0 1 Red 3629 4013
32 ... 400 11 ... 16 2 Black 3629 7910
acces_261_a
630 ... 800 17 2 Black 3899 6011
800 ... 1250 18 3 Black 3899 7011
Fig. 1 Fig.2
For right side operation
Rating (A) Frame size Figure no. Handle colour Reference
acces_148_a_2_cat
32 ... 63 1/2 4 Black 3629 7900
100 ... 400 36 4 Black 3629 7901
fuser_707_a
acces_262_a
630 ... 1250 17 ... 18 5 Black 1437 7911
acces_149_a_2_cat
Frame Handle Handle Defeatable
Rating (A) Operation External IP(1) Reference
size type colour handle
CD 25 63 0/11/12 S1 Black I-0 IP55 Yes 1411 2111
acces_164_a_2_cat
CD 25 63 0/11/12 S1 Black I-0 IP65 Yes 1413 2111
CD 25 63 0/11/12 S1 Red/Yellow I-0 IP65 Yes 1414 2111
CD 25 63 0/11/12 S1 Black I - 0 - Test IP65 Yes 1413 2115
CD 25 63 0/11/12 S1 Red/Yellow I - 0 - Test IP65 Yes 1414 2115 S1 type handle
100 400 13 16 S2 Black I-0 IP55 Yes 1421 2111 S2 type handle
100 400 13 16 S2 Black I-0 IP65 Yes 1423 2111
100 400 13 16 S2 Red/Yellow I-0 IP65 Yes 1424 2111
100 400 13 16 S2 Black I - 0 - Test IP55 Yes 1423 2115
100 400 13 16 S2 Red/Yellow I - 0 - Test IP65 Yes 1424 2115
S3 type handle
acces_236_a_2_cat
100 400 13 16 S2 Black IP65 Yes 142D 2911
100 400 13 16 S2 Red/Yellow IP65 Yes 142E 2911
acces_235_a_2_cat
800 1250 18 S4 Black IP65 Yes 144D 3911
800 1250 18 S4 Red/Yellow IP65 Yes 144E 3911
(1) IP: protection degree according to IEC 60529 standard.
S3 type handle
acces_187_a_1_cat
handle lever.
To be ordered
Handle colour External IP(1) Reference
in multiples of
Black 1 IP65 1493 0000
(1) IP: protection degree according to IEC 60529 standard.
acces_198_a_1_cat
To be ordered
Handle colour Handle Reference
in multiples of
Light grey 50 Type S1, S2 1401 0001
Dark grey 50 Type S1, S2 1401 0011
Light grey 50 S4 type 1401 0031
Dark grey 50 S4 type 1401 0041
Accessories (continued)
Front operation shaft support accessory
Use
This support maintains shaft position for extension shafts greater than 320 mm in length.
fuser_698_a_2_cat
Rating (A) Frame size Reference
50 400 11 16 3899 0400
acces_260_a_2_cat
Description Reference
Shaft guide 1429 0000
acces_369_a_1_cat
- 500 mm.
Rating (A) Frame size Shaft length (mm) Reference
CD 20 CD 32 0 200 1401 0520
CD 20 CD 32 0 320 1401 0532
CD 20 CD 32 0 400 1401 0540(1)
acces_203_a_1_x_cat
CD 25 CD 32 0 S 36 159 200 1401 0520
50 400 11 16 S 36 172 200 1400 1020
630 1250 17/18 S 15 150 200 1400 1220
BS88 for external front operation NFC and DIN For external front operation
Switch body Bar rating Rating (A) Frame size Bar rating (A) Reference
Rating (A) Reference
acces_130_a_1_cat
size (A) 100 125 13 125 3829 9310
acces_131_a_1_cat
100 13 125 3829 9310 160 13 160 3829 9320
CD 160 160 14 200 3829 9320
13a 200 3829 9320
CD 200 250 15 250 3829 9325
160 14 200 3829 9320 400 16 400 3829 9339
200 250 15 250 3829 9325 630 800 17 800 3829 9308
315 400 16 400 3829 9339 800 1250 18 1250 3829 9312
630 800 17 800 3829 9308
1250 18 1250 3829 9312
acces_199_a_2_cat
CD 160 50 1/11 50 27 3629 9227
13 a 200 36 3629 9237
CD 200 63 2/12 63 32 3629 9232
160 14 160 50 3629 9250 100 160 3/13 160 36 3629 9236
200 250 15 250 60 3629 9260 160 4/14 160 50 3629 9250
315 400 16 400 66 3629 9266 250 5/15 250 60 3629 9260
400 6/16 400 60 3629 9266
630 800 17 800 94 3629 9294 630 800 17 800 94 3629 9294
1250 18 1250 120 3629 9212 800 1250 18 1250 120 3629 9212
Solid links
fusib_124_a_2_cat
fusib_123_a_2_cat
BS88 switches
Rating (A) Frame size Fuse size Imax (A) Reference
32 11 A1 32 3629 9003
63 12 A2-A3 63 3629 9006
100 13 A4 160 3629 9010 NFC and DIN switches
CD 160 13a A3-A4 160 3629 9010 Rating (A) Frame size Fuse size Imax(A) Reference
160 14 A4 160 3629 9010 50 1/11 14 x 51 50 6029 0000
160 14 B1-B2 200 3629 9016 63 2/12 00C 160 6420 0000
CD 200 13a A3-A4 160 3629 9010 100 125 3/13 22 x 58 125 6039 0000
200 15 B1-B2 200 3629 9016 125 160 3/13 00 160 6420 0000
250 15 B1-B2-B3 315 3629 9025 160 4/14 0 160 6421 0000
315 16 B1-B2-B3 315 3629 9025 250 5/15 1 250 6421 0001
400 16 B1-B2-B3-B4 400 3629 9040 400 6/16 2 400 6421 0002
630 800 17 C1-C3 800 3629 9063 630 800 17 3 630 6421 0003
1250 18 D1 1250 3629 9120 800 ... 1250 18 4 1250 6441 0005
Accessories (continued)
A-type auxiliary contacts
Use Connection to the control circuit
Pre-break and position 0 and I signalling by 1 or 2 By 6.35 mm fast-on terminal.
NO /NC auxiliary contacts. Electrical characteristics
For low level use, specific auxiliary contacts: 30 000 operations.
please consult us.
References
NO / NC auxiliary contacts
acces_046_a_1_cat
Rating (A) Frame size Contact(s) Reference
CD 20 CD 32 0 1 3999 0001
CD 20 CD 32 0 2 3999 0002
32 400(1) 16 1 3999 0021(2)
32 400(1) 16 2 3999 0022(2)
(1) Side direct operation switch only.
(2) A type auxiliary contacts cannot be mounted in conjunction with integrated solid neutral.
Characteristics
acces_047_a_2_cat
Operating current Ie (A)
Current
Rating (A) 250 VAC 400 VAC 24 VDC 48 VDC
nominal (A)
AC-13 AC-13 DC-13 DC-13
CD 20 400 16 4 2 12 2
acces_056_a_1_cat
References
NC auxiliary contacts
Rating (A) Frame size Contact(s) Reference
CD 20 1250 0 18 1 3999 0702
NO auxiliary contacts
Rating (A) Frame size Contact(s) Reference
CD 20 1250 0 18 1 3999 0701
B
Characteristics
Operating current Ie (A)
250 VAC 400 VAC 24 VDC 48 VDC
Rating (A) AC-15 AC-15 DC-13 DC-13
CD 20 1250 3 1.8 2.8 1.4
acces_051_a_2_cat
Electrical principle 30 000 operations.
The NO + NC S-type auxiliary contacts can be
configured as 2 NC or 2 NO.
References
S-type auxiliary contacts 0-I
for external front and right-side operation (Standard operation)
Rating (A) Frame size Contact type Reference
32 1250 11 18 NC+NO 3999 0041
acces_083_a_1_cat
for external front and right-side operation (TEST operation)
Contact
Rating (A) Frame size Description Reference
type
32 400 11 16 NC+NO TEST + ON 3999 0141
32 400 11 16 2O TEST + ON 3999 0241
Characteristics
Switch body for signalling auxiliary contact Important:
Contact type Operation type Reference
S-type Standard 3999 0003
> For the 400 A rating, an
ST-type TEST 3999 0103
adaptation kit reference
Current
Operating current Ie (A) 3999 0000 must be ordered
Rating (A) 250 VAC 400 VAC in addition to the auxiliary
nominal (A)
AC-13 AC-13 contact kit.
32 1250 20 10 8
Terminal shrouds
Use
Top or bottom IP20 protection (on the front) Two sets required to fully shroud both incoming
against direct contact with terminals or and outgoing terminals.
connection parts.
Accessories (continued)
NFC and DIN fuse blown indication
Use Connection to the control circuit
For fuse cartridge with striker 6.35 mm fast-on terminal.
(size 14 x 51 22 x 58 ; 0 ; 1 ; 2 ; 3 and 4). Mechanical characteristics
Electrical principle 30 000 operations.
A NO/NC auxiliary contact detects that the fuse
has blown.
References
NO/NC type auxiliary contacts for 2 pole
Rating (A) Frame size Fuses Contact(s) Reference
50 11 14 x 51 1st 3994 0405
100 125 13 22 x 58 1st 3994 0210
160 14 0 1st 3994 0216
250 15/16 1-2 1st 3994 0225
400 16 2 1st 3894 0440
630 17 3 1st 3894 1206
fuser_311_a_1_cat
800 1250 18 4 1st 3894 1212
NO/NC type auxiliary contacts for 3 pole
Rating (A) Frame size Fuses Contact(s) Reference
CD 32 0 14 x 51 1st 3994 0303
50 11 14 x 51 1st 3994 0405
100 125 13 22 x 58 1st 3994 0310 DDMM for cylindrical fuses
160 14 0 1st 3994 0316
250 15/16 1-2 1st 3994 0325
400 16 2 1st 3894 0440
630 17 3 1st 3894 1306
800 1250 18 4 1st 3894 1312
50 250 11 2nd 3994 1901
400 16 2 2nd 3994 1902
630 1250 16 - 2 3994 1901
NO/NC type auxiliary contacts for 4 pole or 3 pole + neutral
Rating (A) Frame size Fuses Contact(s) Reference
50 11 14 x 51 1st 3994 0405
fuser_312_a_1_cat
100 125 13 22 x 58 1st 3994 0410
160 14 0 1st 3994 0416
250 15/16 1-2 1st 3994 0425
400 16 2 1st 3894 0440
630 17 3 1st 3894 1406
800 1250 18 4 1st 3894 1412 DDMM for NH fuses
50 250 11 2nd 3994 1901
400 16 2 2nd 3994 1902
630 1250 16 - 2 3994 1901
Characteristics
Operating current Ie (A)
Current
Rating (A) 250 VAC 400 VAC 24 VDC 48 VDC
nominal (A)
AC-13 AC-13 DC-13 DC-13
CD 32 ... 1250 16 4 3 12 2
acces_310_a
Cage terminals
Use
Connection of bare copper cables onto the terminals (without lugs).
References
Rating max (A) Frame size No. of poles Reference
CD 20 63 0 12 2/3/4P integrated
100 160 13/14 3P 5400 3016
100 160 13/14 4P 5400 4016
acces_053_a_1_cat
250 15 3P 5400 3025
250 15 4P 5400 4025
400 16 3P 5400 3040
400 16 4P 5400 4040
Connections
Flexible cable Rigid cable Flexible bar Stripped over X1
Rating (A) cross-section (mm2) cross-section (mm) width (mm) (mm)
100 160 16 95 16 95 13 22
250 16 185 16 185 18 27
400 50 240 50 300 20 34 X R
Dimensions
acces_092_a_1_x_cat
Z
acces_091_a_1_x_cat
Rating (A) A A1 C R X X1 Z C
100 160 47.5 22.5 25 20 8.5 M12 10
250 62 31.5 31.5 25 10.5 M16 14 A
400 71.5 32 38 32 10.5 M20 15
A1
acces_042_a_1_x_cat
CD 20 1250 0 18 external front 2 1499 7701
32 63 1/2 direct 1 3629 7903
100 400 3 6 direct 1 3629 7913
630 1250 17 18 direct 3829 7923
Fig. 1
Locking using K-type CASTELL lock (not supplied)
Rating (A) Frame size Operation Figure n Reference
CD 20 1250 0 18 external front 3 1499 7702
Fig.2 Fig. 3
Label holder
Use
Recognisable self-adhesive label allowing identification of the devices.
To be ordered
Dimensions W x H (mm) Reference
in multiples of
acces_044_a_1_cat
18 x 13 50 7769 9999
Short-circuit capacity
Rated peak withstand current (kA peak)(6) 5.5 5.5 5.5 5.5 9 7.6 10.6 20
Connection
Minimum Cu cable cross-section (mm2) 2.5 2.5 2.5 2.5 6 6 10 25
Maximum Cu cable cross-section (mm2) 16 16 16 16 25 25 25 95
Maximum busbar width (mm) 20
Min. / Max. tightening torque min (Nm) 2/- 2/- 2/3 2 2.5/3 2.5/3 2.5/3 8.3/13
Mechanical characteristics
Durability (number of operating cycles) 20 000 20 000 20 000 20 000 10 000 10 000 10 000 10 000
Weight of 3 P switch (kg) 0.48 0.48 0.48 0.50 0.80 0.80 1 1.5
Weight of 4 P switch (kg) 0.50 0.50 0.50 0.52 1 1 1.3 2
Weight of 1 P extra (kg) 0.2 0.2 0.3 0.5
Frame pitch (mm) 32 27 32 36
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or terminal screen.
(3) 4-pole device with 2 pole in series by polarity.
(4) Poles cannot be juxtaposed.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 400 VAC.
(7) Fuse 800 A, 690 VAC does not exist, tests conducted with bars.
* For fuse size A4: max diameter 31 mm.
** Please ensure that fuse let through current does not exceed short-circuit capacity of the switch (kA peak).
125 to 200 A
Thermal current Ith (40C) 125 A 125 A 160 A CD 160 A 160 A 160 A CD 200 A 200 A
NFC/DIN fuse size -/22 x 58 -/00 -/00 A3-A4*/- A4/0 B1-B2/- A3-A4*/- B1-B2/-
Frame size for direct operation 3 3 3 4 4 5
Switch body size for front and side operation 13 13 13 13 A 14 14 13 A 15
Rated insulation voltage Ui (V) 750 750 750 750 750 750 750 750
Rated impulse withstand voltage Uimp (kV) 8 8 8 8 8 8 8 8
690 VAC AC-23 A / AC-23 B 100(2)/100(2) 100(2)/100(2) 125(2)/125(2) 125(2)/125(2) 125(2)/125(2) 125(2)/125(2) 125(2)/125(2) 200(2)/160(2)
220 VDC DC-20 A / DC-20 B 125/125 125/125 160/160 160/160 160/160 160/160 160/160 200/200
220 VDC DC-21 A / DC-21 B 100/100 100/100 125/125 125/125 125/125 125/125 125/125 200/200
440 VDC DC-22 A / DC-22 B 125(3)/125(3) 125(3)/125(3) 160(3)/160(3) 160(3)/160(3) 160(3)/160(3) 160(3)/160(3) 160(3)/160(3) 200(3)/200(3)
440 VDC DC-23 A / DC-23 B 100(3)/100(3) 100(3)/100(3) 125(3)/125(3) 160(3)/160(3) 125(3)/125(3) 125(3)/125(3) 125(3)/125(3) 200(3)/200(3)
Short-circuit capacity
Rated peak withstand current (kA peak)(6) 20 20 20 20 22.7 22.7 20 32.5
Connection
Minimum Cu cable cross-section (mm2) 35 35 35 35 50 50 35 95
Maximum Cu cable cross-section (mm2) 95 95 95 95 95 95 95 240
Maximum busbar width (mm) 20 20 20 20 20 20 20 32
Tightening torque min (Nm) 8.3/13 8.3/13 8.3/13 8.3/13 8.3/13 8.3/13 8.3/13 20/26
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 10 000 10 000 10 000 10 000 10 000 10 000
Weight of 3 P switch (kg) 1.5 1.5 1.8 1.8 1.8 1.8 1.8 3.2
Weight of 4 P switch (kg) 2 2 2.3 2.3 2.3 2.3 2.3 4.5
Weight of 1 P extra (kg) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1.3
Frame pitch (mm) 36 36 36 36 50 50 36 60
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or phase barrier.
(3) Poles cannot be juxtaposed.
(4) 4-pole device with 2 poles in series per polarity.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 400 VAC.
(7) Fuse 800 A, 690 Vac does not exist, tests conducted with bars.
Short-circuit capacity
Rated peak withstand current (kA peak)(6) 32.5 40 40 70 80 80 90
Connection
Minimum Cu cable cross-section (mm2) 95 185 185 2 x 150 2 x 185
Maximum Cu cable cross-section (mm2) 240 240 240 2 x 300 2 x 300 4 x 185 4 x 185
Maximum busbar width (mm) 32 45 45 63 63 80 80
Tightening torque min (Nm) 20/26 20/26 20/26 40/45 40/45 40/45 40/45
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 10 000 8 000 8 000 5 000 5 000
Weight of 3 P switch (kg) 3.2 4.8 4.8 16 17 25 25
Weight of 4 P switch (kg) 4.5 6.1 6.1 20 21.5 30 30
Weight of 1 P extra (kg) 1.3 1.3 1.3 3 3
Frame pitch (mm) 60 66 66 94 94 120 120
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or terminal screen.
(3) 4-pole device with 2 pole in series by polarity.
(4) Poles cannot be juxtaposed.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 400 VAC.
(7) Fuse 800 A, 690 VAC does not exist, tests conducted with bars.
** Please ensure that fuse let through current does not exceed short-circuit capacity of the switch (kA peak).
External operation
BS88 - FUSERBLOC CD 20 to CD 32 A in size A1
External front operation
44 102 min. 96
1
6.5 37.5 15
44
19 35
14
79.5
98
vfuser_292_d_1_x_cat
70
65 5.2
98 83
98
45
fuser_295_c_1_x_cat
70
70
65 5.2
98 83
fuser_440_b_1_x_cat
65 5.2
98 83
External operation
NFC and DIN - FUSERBLOC 25 to 32 A in size 10 x 38
External front operation External side operation
14
79.5
98
45
fuser_291_d_1_x_cat
79.5
98
45
fuser_294_c_1_x_cat
70
70
70
65 21.5 5.2
65 21.5 5.2
21.5 17
21.5 17
1. With 1 U-type AC: 130 mm.
With 2 U-type AC: 155 mm.
44 102 min. 96
1
6.5 44 36 min. 96 36 min. 44
6.5 37.5 15
44 52.5
44 19
19 35
14
79.5
98
45
fuser_292_d_1_x_cat
fuser_295_c_1_x_cat
79.5
98
70
70
70
65 5.2
65 5.2
98 83
98 83
fuser_440_b_1_x_cat
79.5
98
70
65 5.2
98 83
4.8 14.5
68
15 24
1
6
2
12
6.2
27 27
121 (3P)
148 (4P)
23.5* W
31 31 x 27 45 35
3 18
Z
2
4 5
x 106
*x 52.5
126.5
118
59
2
fuser_624_b_1_x_cat
X 27 27
* to use if pre-break auxiliary contact number > 4 1. S-type auxiliary contact NO + NC to use if block number > 4
W: 84.5 for BS88; 87 for NFC and DIN 2. Rear connection (option)
X: 153 only for DIN 3. 1 or 2 pre-break auxiliary contact (fuse blown indication)
Y: 85 only for DIN 4. 1 to 4 pre-break auxiliary contact for signalisation
Z: 26 only for DIN 5. Additional contact holder for U-type AC
S1 type
Box size 0 0.78 0.78 I
0 20 20
65 1.46
TEST 90 4 0.27 90
47 4 0.27 37
20
47
0.78
3.07
0.55
14
78
I 0
2.75
70
fuser_712_a_1_gb_cat
0.55
14
20
0.78
*x 5.5 29
min 50
4.8 14.5 max 230
68
15 24
1
6
2 12 6.2
32 32
136 (3P)
168 (4P)
min W
max X
132
31 36 x 32 50 18 35
3
2
4
x 106
*x 52.5
126.5
118
59
2
fuser_625_b_1_x_cat
5.4
32 32
* to use if pre-break auxiliary contact number > 4 1. S-type auxiliary contact NO + NC to use if block number > 4
W: 124 + N x 23.5 for BS88; 139 for NFC and DIN 2. Rear connection (option)
X: 145 + N x 23.5 for BS88; 145 for NFC and DIN 3. 1 to 4 pre-break auxiliary contact for signalisation
Y: 159 only for DIN 4. Additional contact holder for U-type AC
Z: 145 only for DIN
* x 5.5 29
4.8 14.5 min 50
max 230
68
41
2
8
20 8.7
36 36
148 (3P)
184 (4P)
min 139
max 145
132 40 x 36 54 18 35
31 5.4
3 4
53
fuser_626_a_1_x_cat
2.5
x 52.5*
x 127
126.5
141
162
62
6
2.5
141
8.5
53
2.5 20
19.5 36 36
X
* to use if pre-break auxiliary contact number > 4 1. S-type auxiliary contact NO + NC to use if block number > 4
X: 179 for BS88 / NFC and DIN 100 to 125 A 2. Rear connection (option)
189 for NFC and DIN 125 to 160 A 3. 1 to 4 pre-break auxiliary contact for signalisation
4. 1 or 2 pre-break auxiliary contact (fuse blown indication)
5. Terminal shrouds
6. Additional contact holder for U-type AC
68
1
39
2
10
18
8.7
36 36
148 (3P)
184 (4P)
min 145
max 225
139
36 40 x. 36 54 18 35
53
3
3
5
x. 52.5*
x. 130
126.5
141
162
78
3
8.5
53
4
fuser_627_b_1_x_cat
3 18
20 36 36
* to use if pre-break auxiliary contact number > 4 3. 1 to 4 pre-break auxiliary contact for signalisation
1. S-type auxiliary contact NO + NC to use if block number > 4 4. Terminal shrouds
2. Rear connection (option) 5. Additional contact holder for U-type AC
BS88 - FUSERBLOC 160 A in fuse size A4 & B1-B2 NFC and DIN - FUSERBLOC 160 A in fuse size 0
*x 5.5 29
4.8 14.5
min 50
max 23
68
1
41
2
8
20 8.7
50 50
190 (3P)
240 (4P)
min 145
max 225
136.5 54 x 50 68 18 35
31 5.4
3 4
2.5
x 52.5*
x 140
126.5
141
62
2.5
174
fuser_628_b_1_x_cat
5 8.5
20
* to use if pre-break auxiliary contact number > 4 4. 1 or 2 pre-break auxiliary contact (fuse blown indication)
1. S-type auxiliary contact NO + NC to use if block number > 4 5. Terminal shrouds
2. Rear connection (option) 6. Additional contact holder for U-type AC
3. 1 to 4 pre-break auxiliary contact for signalisation
*x 5.5 29
4.8 14.5
min 50
max 230
68
1
52
17
2
32
11
60 60
234 (3P)
294 (4P)
min 154 64 x 60 3P 86 25 35
max 225 4P 146
146 6.4
75
31
4
2.5
6
*x 52.5
x 162
126.5
195
84
166
2.5
185
fuser_629_b_1_x_cat
75
11
5
2.5 32
19.5 60 60
251
* to use if pre-break auxiliary contact number > 4 4. 1 or 2 pre-break auxiliary contact (fuse blown indication)
1. S-type auxiliary contact NO + NC to use if block number > 4 5. Terminal shrouds
2. Rear connection (option) 6. Additional contact holder for U-type AC
3. 1 to 8 pre-break auxiliary contact for signalisation
BS88 - FUSERBLOC 315 A in fuse size B1-B2-B3 NFC and DIN - FUSERBLOC 400 A in fuse size 2
FUSERBLOC 400 A in fuse size B1-B2-B3-B4
*x 5.5 29
4.8 14.5
min 50
max 230
68
auxiliary contact (fuse blown indication)
5. Terminal shrouds
6. Additional contact holder for U-type AC
1
54
2
14.5
50
11
66 66
252 (3P)
318 (4P)
min 157 70 x 66 91 25 35
max 225
149 6.4
31
75
4
3
6
*x 52.5
x 172
126.5
175
205
84
3
200
fuser_630_b_1_cat
75
5
11
3 50
20 66 66
260
47
0.78
3.07
0.55
14
fuser_713_a_1_gb_cat
78
I 0
0.55
14
20
0.78
4.92
125
E min. J1 J
fuser_634_e_1_x_cat
H 14
1
20
8.2
AC
AA
BA
N
DA
W
2
U T T
Y
Z T T
DB
Terminal Switch
Dimensions Switch body Connection
Rating Frame shrouds mounting
Fuse size
(A) size A 3 A 4 E E F3 F4 J3 J4 J1 J1
AC H DA DB N T U W Y Z AA BA
P P min max P P P P 3P 4P
32 A1 11 264 318 100(1) 146(1) 242 296 87 102 129 138 165 85 153 90 27 118
63 A2-A3 12 294 358 124 145 272 336 116.5 121 153 157 189 159 145 90 32 118
100 A4 13 318 390 124 145 268 296 368 116(2) 133 169 169 205 141 179 128 36 20 8.5 2.5 19.5 162 141
CD
A3-A4 13 A 318 390 145 225 268 296 368 139 133 169 169 205 128 36 18 8.5 3 20 162 141
160
160 A4 14 402 502 124 225 268 380 480 136.5 176 226 212 262 174 229 128 50 20 8.5 2.5 19.5 162 141
160 B1-B2 14 402 502 130 225 268 380 480 136.5 176 226 212 262 174 229 128 50 20 8.5 2.5 19.5 162 141
CD
A3-A4 13 A 318 390 145 225 268 296 368 139 133 169 169 205 128 36 18 8.5 3 20 162 141
200
200 B1-B2 15 490 610 130 225 345 468 588 146 213 273 263 323 185 251 155 60 32 11 2.5 19.5 195 166
250 B1-B2-B3 15 490 610 154 225 345 468 588 146 213 273 263 323 185 251 155 60 32 11 2.5 19.5 195 166
315 B1-B2-B3 16 526 658 154 225 355 504 636 149 231 297 281 347 200 260 168 66 50 11 3 20 205 175
400 B1-B2-B3-B4 16 526 658 157 225 355 504 636 149 231 297 281 347 200 260 168 66 50 11 3 20 205 175
(1) 1 AC: + 23.5 mm / 2 AC: + 47 mm.
(2) 132 mm with 2 AC.
E min. J1 J
fuser_634_e_1_x_cat
H 14
1
20
8.2
AC
AA
BA
N
DA
W
2
U T T
Y
Z T T
DB
Terminal Switch
Overall dimensions Switch body Connection
Rating Fuse Frame shrouds mounting
(A) size size A A E E F F J J J1 J1
AC H DA DB N T U W Y Z AA BA
3p 4p min max 3P 4P 3P 4P 3P 4P
14 x
50 11 264 318 100(1) 146(1) 121 148 87(1) 102 129 138 165 85 153 90 27 118
51
(2)
63 00C 12 294 358 125 145 136 168 116.5 121 153 158 189 159 145 90 32 118
22 x (2)
100 13 318 390 135 145 268 148 184 116 133 169 169 205 141 187 128 36 20 8.5 2.5 19.5 162 141
58
22 x
125 13 318 390 135 145 268 148 184 116(2) 133 169 169 205 141 179 128 36 20 8.5 2.5 19.5 162 141
58
125 00 13 318 390 135 145 268 148 184 126.5 133 169 169 205 141 193 128 36 20 8.5 2.5 19.5 162 141
160 00 13 318 390 135 145 268 148 184 126.5 133 169 169 205 141 193 128 36 20 8.5 2.5 19.5 162 141
160 0 14 402 502 145 225 268 190 240 136.5 176 226 212 262 174 229 128 50 20 8.5 2.5 19.5 162 141
250 1 15 490 610 154 225 345 234 294 146 213 273 263 323 185 251 155 60 32 11 2.5 19.5 195 166
400 2 16 526 658 157 225 355 252 318 149 231 297 281 347 200 260 168 66 50 11 3 20 205 175
112 96
91.5 6.5 37.5 15
44
19
14
79.5
45
98
fuser_148_c_1_x_cat
65 5.2
98 83
FUSERBLOC 32 to 400 A
2 H T J 3
AD
R
S
70
AC
BA
AA
N
DA
1 Y
fuser_064_b_1_x_cat
31 W
U T
C AB
DB A
14
14
79.5
45
98
79.5
98
45
fuser_148_c_1_x_cat
fuser_138_c_1_x_cat
65 5.2
65 21.5 5.2
98 83
21.5 17
FUSERBLOC 50 to 400 A
2 H T J 3
AD
R
S
70
AC
BA
AA
N
DA
1 Y
31 W
fuser_064_b_1_x_cat
U T
C AB
DB A
85.5
14.5 11.5
10.5 4
min 265
68
2
46
3
20
51 min 15
94 94
364 (3P)
458 (4P)
min 265
250 Fix 284 (3P)
Fix 378 (4P)
155 65 34
85.5
79.5 11
235.5
7
22
x 250
300
260
90
7
235.5
fuser_631_b
300
5 7
85.5
13 9
59
51
380 94 94
1. Direct operation
2. S-type auxiliary contact NO + NC
3. Rear connection (option)
4. 1 to 8 pre-break auxiliary contact for signalisation
5. Terminal shrouds
47
0.78
47
78
0.55
14
I 90
20
0.78
0.55
14
fuser_714_a_1_gb_cat
210
0 0.55 0.55
1.46 14 14
37
61
85.5
14.5 11.5
2. S-type auxiliary contact NO + NC
3. Rear connection (option)
4. 1 to 8 pre-break auxiliary contact for signalisation 10.5
5. Terminal shrouds
4
min 304
68
2
46
3
120 120 min 15
442 (3P)
562 (4P)
79.5 11
34
237.5
7
22
x 250
260
300
90
7
237.5
fuser_632_b_1_x_cat
87.5
7
355
59
120 120
5
295
S3 type
Box size 18
3.07 I
78
90
210
0
37
47
61
20 20
S4 type
0 1414
78 90
350
I
fuser_715_a_1_gb_cat
60
Strong points
FUSERBLOC
630 to 1250 A
> Limitation of short-circuit
current.
Large range
fuser_439_a_1_cat
Function Advantages
FUSERBLOC fuse combination switches Limitation of short-circuit current
combined with high speed fuses (UR) The limitation of short-circuit current provided
provide optimal breaking and making on by the fuse solution is the most performant
load, safety isolation and protection of power and economical on the market (UR fuses).
semiconductors (variable speed drives,
inverters)
Characteristics
FUSERBLOC for 690 VAC UR cylindrical fuses
FUSERBLOC CD 50 A for fuse size 14 x 51
Fuse rating (A) 10 12 16 20 25 32 40 50
Max. I for the FUSERBLOC (A) 10 12 16 20 25 29 36 40
FUSERBLOC CD 125 A for fuse size 22 x 58
Fuse rating (A) 20 25 32 40 50 63 80 100
Max. I for the FUSERBLOC (A) 20 25 32 40 50 63 71 85
References
Direct side operation
Fuse rating (A) Auxiliary contact pre-break
No. of poles Switch body Direct handle
Frame size and position
2P 3615 2005
50 A / 14 x 51 Black
3P 3615 3005
1 3629 7900 1 contact NO/NC
4P 3615 6005 3999 0021
2P 3615 2011 2 contacts NO/NC
125 A / 22 x 58 Black 3999 0022
3P 3615 3011
3 3629 7901
4P 3615 6011
Accessories
Other accessories: See the FUSERBLOC pages
Characteristics
FUSERBLOC for DIN 43620 UR knife-edge fuses
FUSERBLOC 160 A for fuse size 000 and 00
Fuse rating (A) 10 16 20 25 32 40 50 63 80 100 125 160 200 250 315
Max. I for the FUSERBLOC (A) 10 16 20 25 32 32 37 44 51 92 105 121 140 140 140
FUSERBLOC 250 A for fuse size 1*
Fuse rating (A) 40 50 63 80 100 125 160 200 250 315 350 400
Max. I for the FUSERBLOC (A) 40 50 63 80 100 125 155 178 205 210 215 220
FUSERBLOC 400 A for fuse size 2
Fuse rating (A) 200 250 315 350 400 450 500 550 630 700
Max. I for the FUSERBLOC (A) 200 250 285 310 330 330 340 340 350 350
FUSERBLOC 630 A for fuse size 3
Fuse rating (A) 500 550 630 700 800 900 1000
Max. I for the FUSERBLOC (A) 360 380 420 450 480 500 510
References
Direct side operation
2P 3811 2063
Black IP65 Black IP65 200 mm
630 A / 3 1433 3111 1437 3111 1400 1220
3P 3811 3063 3890 8063(1)
17 Red / Yellow IP65 Red / Yellow IP65 320 mm
1434 3111 1438 3111 1400 1232
4P 3811 6063 3890 9063(1)
(1) Terminal shrouds for FUSERBLOC fitted fuse blown microswitch.
Accessories
FUSERBLOC for DIN 43620 UR knife-edge fuses
Terminal shrouds for FUSERBLOC fitted fuse blown microswitch
Use
Protection against direct contact with live parts situated in the fuse
compartment for FUSERBLOC fitted with UR fuses with fuse blown
auxiliary contacts.
Accessories(2) Options(3)
No. of
Rating (A) Fuses (1) References References
poles
160 00 2P 3990 7015 3999 7015
160 00 3P 3990 8015 3999 8015
160 00 4P 3990 9015 3999 9015
160 0 2P 3990 7016 3999 7016
160 0 3P 3990 8016 3999 8016
160 0 4P 3990 9016 3999 9016
250 1 2P 3990 7024 3999 7024
250 1 3P 3990 8024 3999 8024
acces_221_a
Characteristics
FUSERBLOC for UR fuses type K/50
FUSERBLOC V 800 A for BK fuses size 2
Fuse rating (A) 400 450 500 550 630 700 800 900 1000 1100 1250
Max. I for the FUSERBLOC (A) 380 420 440 450 500 520 530 530 530 540 550
FUSERBLOC 1250 A for fuse size 3
Fuse rating (A) 500 550 630 700 800 900 1000 1100 1250 1400 1500 1600 1800 2000
Max. I for the FUSERBLOC (A) 500 550 620 630 720 790 870 940 1050 1100 1100 1100 1100 1100
References
Front operation
Auxiliary
Fuse
Rating (A) / Shaft for contact pre- Terminal
No. of poles Switch body only(1) Direct handle External handle protection
Fuse external handle break and shrouds
covers
position
800 A / 3P 3680 3081 Black IP55
200 mm
2 4P 3680 6081 1443 3111(2)
Please consult 1400 1220 Please consult Please consult Please consult
Red / Yellow
1250 A / 3P 3680 3121 us 320 mm us us us
IP65
3 1400 1232
4P 3680 6121 1444 3111
(1) Please consult us.
(2) Standard.
Characteristics
FUSERBLOC for UR fuses type K/110
FUSERBLOC 250 A for fuse size 1* (690 VAC)(1)
Fuse rating (A) 40 50 63 80 100 125 160 200 250 315 350 400 450 500 550 630
Max. I for the
40 50 63 80 100 120 140 165 195 215 230 240 240 240 230 240
FUSERBLOC (A)
(1)
FUSERBLOC 400 A for fuse size 1* (690 VAC)
Fuse rating (A) 200 250 315 350 400 450 500 550 630 700 800 900
Max. I for the FUSERBLOC (A) 145 165 200 220 240 265 290 310 340 370 395 395
FUSERBLOC 500 A for fuse size 2* (690 VAC)(1)
Fuse rating (A) 400 450 500 550 630 700
Max. I for the FUSERBLOC (A) 320 345 370 390 425 460
FUSERBLOC 630 A for fuse size 2 to 690 VAC(1)
Fuse rating (A) 800 900 1000 1100 1250
Max. I for the FUSERBLOC (A) 495 545 590 610 620
FUSERBLOC 800 A for fuse size 3 to 690 VAC(1)
Fuse rating (A) 500 550 630 700 800 900 1000 1100 1250 1400 1500 1600 1800 2000
Max. I for the FUSERBLOC (A) 370 395 440 480 535 590 645 695 760 800 800 800 800 800
FUSERBLOC 1250 A for fuse size 3 Please consult us.
(1) For UR fuses type K/110 1250 VAC, please consult us.
References
External right side or front operation switch
Auxiliary contact
Rating (A) / Direct side Direct front Fuse protection
No. of poles Switch body pre-break and Terminal shrouds
Fuse handle handle covers
signalisation
250 A / 2P 36U1 2024
2P 2P
1* 3P 36U1 3024 Black 3990 2839(1) 1 contact NO/NC 3998 2025
400 A / 2P 36U1 2039 3629 7901 3P 3999 0021 3P
1 3990 3839(1) 3998 3025
3P 36U1 3039
500 A / 2P 38U1 2050
2 3P 38U1 3050
2P 2P
630 A / 2P 38U1 2063 Black 3890 2U63(1) 3898 2080
1 contact NC
2 3P 38U1 3063 Black 3899 6011 3P 3999 0701 3P
1437 7911 3890 3U63(1) 1 contact NO 3898 3080
800 A / 2P 38U1 2080
3 3999 0702
3P 38U1 3080
(1)
1250 A / 2P 38U1 2120 Black 3890 2U12 3898 2120
3 3P 38U1 3120 3899 7011 3890 3U12(1) 3898 3120
(1) Terminal shrouds for FUSERBLOC fitted fuse blown microswitch.
2P 38U1 2024
250 A /
1* S2 type S2 type
3P 38U1 3024 Black IP55 Black IP55 2P 2P
1421 2111 1425 2111 320 mm 3990 2839(1) 3998 2025
S2 type S2 type 1400 1032 3P 3P
2P 38U1 2039 Red IP65 Red/yellow IP65 3990 3839(1) 3998 3025
400 A / 1424 2111 1428 2111
1
3P 38U1 3039
2P 38U1 2050
500 A /
2
3P 38U1 3050
S3 type 1 contact NC
Black IP65 2P 3999 0701 2P
2P 38U1 2063
630 A / 1433 3111 3890 2U63(1) 1 contact NO 3898 2080
2 S3 type 3P 3999 0702 3P
3P 38U1 3063 Red/Yellow IP65 S3 type 3890 3U63(1) 3898 3080
1434 3111 Black IP65
1437 3111 320 mm
2P 38U1 2080
800 A / S3 type 1400 1232
3 Red/Yellow IP65
3P 38U1 3080 1438 3111
Accessories
FUSERBLOC for UR fuses type K/110
Terminal shrouds for FUSERBLOC fitted fuse blown microswitch
Use
Protection against direct contact with live parts situated in the fuse
compartment for FUSERBLOC fitted with UR fuses with fuse blown
auxiliary contacts.
Accessories(1) Option(2)
No. of
acces_221_a
Strong points
A complete range
References
NFC and DIN - Front operation - Switch body with a shunt trip coil - 230 VAC
Rating (A) / No. of Direct External Shaft for 1st position Terminal Terminal Inter phase
Fuse(4) poles Switch body handle handle external handle AC Tripping AC shrouds top screens top barrier
3P 3520 3063 3998 3063
630 A /
3
4P 3520 6063 3998 4063
3P 3520 3080
800 A /
4
4P 3520 6080
(1) Standard.
(2) Bottom terminals protection screen as standard.
(3) Only one of the two T4 fuses should be equipped with striker.
(4) For the fuses: see page 236 "NFC-DIN industrial fuselinks 0.16 to 1250 A".
* Two size 4 DIN fuses in parallel per pole.
Accessories
Direct front operation handle
acces_156_a_2_cat
630 1800 Red consult us
acces_151_a_2_cat
acces_166_a_2_cat
Alternative S-type handle cover colours
Use
For single lever S3 type handles.
Other colours: consult us.
acces_198_a_2_cat
Colour To be ordered by multiple Reference
Light grey 50 1401 0001
Dark grey 50 1401 0011
acces_049_a_1_cat
Voltage Reference Reference
24 VAC 3990 1024 3991 1024
48 VAC 3990 1048 3991 1048
110 VAC 3990 1110 3991 1110
230 VAC 3990 1220 included
400 VAC 3990 1380 3991 1380
Undervoltage trip coil
12 VDC 3990 2012 3991 2012
24 VDC 3990 2024 3991 2024
48 VDC 3990 2048 3991 2048
acces_050_a_1_cat
110 / 200 VDC 3990 2220 3991 2220
Auxiliary contacts
References
NO/NC position contact
Rating (A) Position AC Reference
630 1800 1st 3999 0051
630 1800 2nd 3999 0052 acces_048_a_1_cat
Accessories (continued)
Fuse blown indication
Use
For DIN fuse cartridges with striker. NO/NC changeover contact
Rating (A) No. of poles Position AC Reference
Electrical principle 630 1800 3/4 P 1st included
A NO/ NC auxiliary contacts detects that the fuse has blown.
Characteristics
Connection to the control circuit
Operating current Ie (A)
By 6.35 mm fast-on terminal. 250 VAC 400 VAC 24 VDC 48 VDC
Nominal
Rating (A) current (A) AC-13 AC-13 DC-13 DC-13
Electrical characteristics 630 1800 16 12 8 12 2
30 000 operations.
Terminal shrouds
Use Advantages
Top or bottom protection against direct Perforations allowing remote thermographic
contact with terminals or connection parts. inspection without removal.
acces_212_a_2_cat
Rating (A) No. of poles Position Reference
630 3P top 3998 3063
630 4P top 3998 4063
Terminal screens
Use Rating (A) No. of poles Position Reference
Top or bottom protection against direct 800 1600 3P top 2998 3120
contact with terminals or connection parts. 800 1600 4P top 2998 4120
1800 3P top 2998 3180
1800 4P top 2998 4180
800 1800 3/4 P bottom included
of the handle.
Rating (A) Operation Reference
- using RONIS 1104 A lock
630 1250 front direct 3999 7007
JDX!"SNADLNTMSDCCHQDBSKX
on the padlockable handle, 1600 1800 front direct 3999 6117
- locking using RONIS EL11AP lock 630 1800 external front 1499 7701
(not supplied).
Short-circuit capacity
Rated peak withstand current (kA peak)(6) 55 80 100 120 120
Connection
Minimum Cu cable section (mm2) 2 x 150 2 x 185 4 x 240
Minimum Cu busbar section (mm2) 2 x 30 x 5 2 x 40 x 5 2 x 60 x 5 2 x 80 x 5
Maximum Cu cable section (mm2) 2 x 300 2 x 300 4 x 185 6 x 240 8 x 240
Maximum Cu busbar width (mm) 50 63 100 100 100
Tightening torque min (Nm) 20 20 40
Mechanical characteristics
Durability (number of operating cycles) 5000 5000 5000 3000 3000
Weight of 3 P switch (kg) 20 25 27 54 59
Weight of 4 P switch (kg) 24 30 32 70 75
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or phase barrier.
(3) Poles cannot be juxtaposed.
(4) 4-pole device with 2 pole in series by polarity.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 400 VAC.
Dimensions
SIDERMAT combination 630 A
Direct front operation
60
1
175
665
515
190
sdmat_006_c_1_x_cat
60 15
2
8 13 80 80 73.5 114
3p: 307 - 4p: 387
1
165
190
585
765
sdmat_005_a_1_x_cat
75 15
120 120 91 2
8 3p: 382 - 4p: 502 109
190
748
778
sdmat_013_a_1_x_cat
38
2
8 120 120 91
3p: 382 - 4p: 502 118
240
190
748
778
sdmat_014_e_1_x_cat
38
2
8 120 120 91
3p: 382 - 4p: 502 118
Connection terminals
SIDERMAT combination - 630 A SIDERMAT combination
800 to 1250 A
15
16 x 11
sdmat_052_a_1_x_cat
sider_074_a_1_x_cat
30
33
17 25
10
30
19 25 19
19 x 11 33
50 63
80 100
13
20 40
50
sdmat_059_a_1_x_cat
sdmat_054_a_1_x_cat
sdmat_055_a_1_x_cat
40
40 20
40 20
40 13
13
90
Strong points
A complete range
Configurations
5
3
1. Direct front operation.
2. External front operation. 4
3. NO/NC position AC.
4. NO/NC AC wired to ready mounted
transmission coil.
5. Terminal shrouds.
fusom_060_b_1_x_cat
2
1
References
BS88 - Front and side operation - Switch body with a shunt trip coil - 230 VAC
Front Side Shaft for Auxiliary Auxiliary
Rating (A) No. of operation operation Direct External external contact contact Terminal Terminal Inter phase
Fuse (1) poles Switch body Switch body handle(2) handle handle position tripping shrouds(3) screens(4) barrier
(1) For the fuses: see page 230 "BS88 industrial fuselinks".
(2) Standard.
(3) Top/bottom.
(4) Bottom terminals protection screen as standard.
References
NFC and DIN - Front operation - Switch body with a shunt trip coil - 230 VAC
3P 3650 3026
250 A / 1
4P 3650 6026 3P 3P
3994 1304 3998 3040(2)
4P 4P
3P 3650 3041 3994 1404 3998 4040(2)
Black
400 A / 2
3999 6201(1)
4P 3650 6041
S3 type
Black 1st contact
3P 3650 3064 IP55 200 mm NO/NC 3P 3P
1431 3511(1) 1401 1520 3999 0051 1 contact 3994 1306 3998 3063(2)
630 A / 3 NO/NC
S3 type 320 mm 2nd contact 3999 0031 4P 4P
4P 3650 6064 Red/yellow 1401 1532(1) NO/NC 3994 1406 3998 4063(2)
IP55 3999 0052
1432 3511
3P 3650 3080
800 A / 4
4P 3650 6080 3P 3P 3P
3994 1312 3998 3120(3) 2998 0003
Black
3999 6012(1)
4P 4P 4P
3P 3650 3121 3994 1412 3998 4120(3) 2998 0004
1250 A / 4
4P 3650 6121
(1) Standard.
(2) Top/bottom.
(3) Bottom terminals protection screen as standard.
NFC and DIN - Side operation - Switch body with a shunt trip coil - 230 VAC
3P 3655 3026
250 A
/1
4P 3655 6026 3P 3P
3994 1304 3998 3040(2)
4P 4P
3P 3655 3041 3994 1404 3998 4040(2)
400 A
/2
4P 3655 6041
S3 type
Black 1st contact
3P 3655 3064 IP55 NO/NC 3994 1306 3998 3063(2)
1435 3511(1) 3999 0051 1 contact
630 A Black 200 mm
NO/NC
/3 3999 6012(1) 1403 1520
S3 type 2nd contact 3999 0031
4P 3655 6064 Red NO/NC 3994 1406 3998 4063(2)
IP55 3999 0052
1436 3511
3P 3655 3080
800 A
/4
4P 3655 6080 3P 3P 3P
3994 1312 3998 3120(3) 2998 0003
4P 4P 4P
3P 3655 3121 3994 1412 3998 4120(3) 2998 0004
1250 A / 4
4P 3655 6121
(1) Standard.
(2) Top/bottom.
(3) Bottom terminals protection screen as standard.
Accessories
Direct handle
Front operation
Rating (A) Handle colour Reference
250 630 Black 3999 6201
acces_156_a_2_cat
800 1250 Black 3999 6012
250 1250 Red consult us
Side operation
Rating (A) Handle colour Reference
250 1250 Black 3999 6012
250 1250 Red 3999 6013
External handle
Front operation
Handle
Rating (A) type Handle colour External IP Reference
250 1250 S3 Black IP55 1431 3511
250 1250 S3 Red IP55 1432 3511
acces_166_a_2_cat
acces_151_a_1_cat
Side operation
Handle
Rating (A) type Handle colour External IP Reference
250 1250 S3 Black IP55 1435 3511
250 1250 S3 Red IP55 1436 3511
S3 type handle S3 type handle
acces_187_a_1_cat
To be ordered
Handle colour in multiples of External IP(1) Reference
Black 1 IP65 1493 0000
(1) IP: protection degree according to IEC 60529 standard.
Side operation
Rating (A) Dimension Y (mm) Shaft length (mm) Type Reference
250 1250 78 200 200 15 x 12 1403 1520 X Y
Auxiliary contact
Use Connection to the control circuit
Pre-break and signalling of positions 0 and I: By 6.35 mm fast-on terminal.
1 to 2 NO/NC auxiliary contacts. Characteristics
Coil tripping Auxiliary contact NO/NC IP2.
1 to 2 NO/NC auxiliary contacts. Electrical characteristics
30 000 operations.
acces_048_a_1_cat
250 1250 2nd AC 3999 0112
NO/NC contact signalling coil tripping
Rating (A) Position AC Reference
250 1250 1 AC 3999 0031
Accessories (continued)
Current-reducing resistor for undervoltage trip coil
Terminal shrouds
Use Advantage
Top or bottom protection Perforations allowing
against direct contact with remote thermographic
terminals or connection inspection without removal.
parts.
Rating (A) No. of poles Position Reference
250 400 3P top or bottom 3998 3040(1)
3998 4040(2)
acces_213_b_1_cat
250 400 4P top or bottom
630 3P top or bottom 3998 3063(1)
630 4P top or bottom 3998 4063(2)
(1) Reference composed of 3 pieces.
(2) Reference composed of 4 pieces.
Terminal screen
Use
Top or bottom protection against direct contact with
terminals or connecting parts.
Rating (A) No. of poles Position Reference
fusom_059_a_1_cat
Cage terminals
Use
Connection of bare copper cables onto the terminals (without lugs).
References
Rating max (A) No. of poles Reference
250 3P 5400 3025
acces_053_a_1_cat
250 4P 5400 4025
400 3P 5400 3040
400 4P 5400 4040
500 ... 630 3P 5400 3063
500 ... 630 4P 5400 4063
Connections
Flexible cable Rigid cable Width
cross-section cross-section flexible bar Stripped
Rating (A) (mm )2 2
(mm ) (mm) over (mm) X1
acces_091_a_1_x_cat
250 16 185 16 185 18 27
acces_092_a_1_x_cat
400 50 240 50 300 20 34 R
X
500 ... 630 70 300 70 300 24 34
Z
C
Dimensions
A
Rating (A) A A1 C R X X1 Z
A1
250 62 31.5 31.5 25 10.5 M16 14
400 71.5 32 38 32 10.5 M20 15
500 ... 630 76.5 37 38 40 12.5 M20 15
acces_010_b_1_x_cat
q using RONIS 1104 A lock (key BC 3318) to be mounted directly on the padlockable handle.
q Locking using CASTELL K (not supplied)
q Locking using RONIS EL11AP (not supplied).
Label holder
Use
Recognisable self-adhesive label allowing identification of the devices.
acces_044_a_1_cat
Short-circuit capacity
Rated peak withstand current (kA peak)(6) 30 45 60 80 80
Connection
Min. connection wire range 95 185 2 x 150
Minimum Cu busbar section (mm2) 2 x 30 x 5 2 x 60 x 5 2 x 60 x 5
Maximum Cu cable section (mm2) 240 240 2 x 300 4 x 185 4 x 185
Maximum Cu busbar width (mm) 40 40 50 100 100
Tightening torque min (Nm) 20 20 40 20
Mechanical characteristics
Durability (number of operating cycles) 8000 8000 5000 5000 5000
Weight of a 3 pole device (kg) 7 8 16 28 28
Weight of a 4 pole device (kg) 8.5 9.5 19 33 33
(1) Category with index A = frequent operation - Category with index B = infrequent operation.
(2) With terminal shrouds or phase barrier.
(3) Poles cannot be juxtaposed.
(4) 4-pole device with 2 pole in series by polarity.
(5) The power value is given for information only, the current values vary from one manufacturer to another.
(6) For a rated operational voltage Ue = 400 VAC.
Dimensions
Front operation
BS88 - FUSOMAT 250 to 800 A
NFC and DIN - FUSOMAT 250 to 630 A
Direct front operation
External front operation
A Z
F
P M
U Y 1
W
V1
K1
AC
BA
AA
B
N
fusom_046_d_1_x_cat
190
V2
210
R 2
X T H 1
J C E min. 61
1. Terminal shrouds.
2. Reset 70.
Terminal
Dimensions shrouds Switch body Switch mounting Connection
J J P P X X
Rating (A) A 3p. A 4p. B C E AC F 3p. F 4p. H 3p. 4p. K1 M N 3p. 4p. R T U V1 V2 W 3p. 4p. Y Z AA BA
250 435 495 305 307 297 343 380 285 345 221 253 313 115 210 180 10 70 7 65 32 35 43 11 31 46 3 67 238 208
400 435 495 305 307 293 343 380 285 345 221 253 313 115 210 180 10 70 7 65 32 35 43 13 31 46 5 69 238 208
630 490,5 570,5 350 348 341 440 470 345,5 425,5 268 308 388 150 250 250 20 100 9 80 50 50 50 13 36 65 7 72 300 260
800 490,5 570,5 350 348 341 440 470 345,5 425,5 268 308 388 150 250 250 20 100 9 80 50 50 50 13 36 65 7 72 300 -
330
F
16 M 76 106
7 1 1
80
4
165
509
363
250
190
fusom_048_f_1_x_cat
68
2
210
Strong points
Conformity to standards(1)
Advantages
Improved safety A complet range of functions
q On load make and break power circuit q Compact footprints.
applications. q Front or side operation.
q Double break by phase. q Flange operation.
q Touch safe covers. q NFPA 79 compliant kits.
q Voltage sensing terminals.
High breaking capacity.
q Up to 200 kA Short circuit rating.
References
Fusible disconnect
Rating (A) U type
Fuses Front external External right Shaft external auxiliary Terminal
Frame size No. of poles Switch body Direct handle handle side handle handle NFPA79 kit contacts shrouds
3P 3710 3003
S0 type
200 mm
CD 30 A 7.9 inches
3 P + switched Black
CC 3710 4003 S0 type 1405 0620
neutral 3729 4012
1 Black IP65 320 mm
I-0 12.6 inches
1, 3R, 12 1405 0632
3 P + solid 1493 0111 400 mm
3710 5003 4, 4X 15.7 inches
neutral
149D 0111 1405 0640
3729 4532
S1 type S1 type
Black IP65 200 mm
3P 3710 3004
I-0 7.9 inches
1, 3R, 12 1401 0520
141F 2111 320 mm
CD 30 A 4, 4X 12.6 inches
3 P + switched 141D 2111 1401 0532
J 3710 4004 3729 4014
neutral 400 mm
2
15.7 inches
1401 0540
3 P + solid
3710 5004
neutral
1 contact NC
3999 0701
standard
1 contact NO
3999 0702
2P 3861 2004
30 A
J 3P 3861 3004
4 S1 type
Black
I-0
1, 3R, 12 S1 type S1 type
4P 3861 6004 Defeatable Black I - 0 4, 4X 200 mm
141F 2111 141H 6111 7.9 inches
Black I-0 S1 type 1400 1020
3729 7540
3629 7910 4, 4X Red / yellow
Defeatable I-0 320 mm
2P 3861 2005 141D 2111 4, 4X 12.6 inches
I - 0 - Test 141I 6111 1400 1032
4, 4X
Defeatable
60 A 141D 2115
J 3P 3861 3005
4
4P 3861 6005
References (continued)
Rating (A)
fuses No. of Front external External right Shaft for U type auxiliary Terminal
Frame size poles Switch body Direct handle handles side handle(1) external handle NFPA79 kit contacts shrouds
2P 3861 2006
60 A
J 3P 3861 3006
5
4P 3861 6006
S2 type standard
2P 3861 2010 Black
I-0
100 A 1, 3R, 12 S2 type
J 3P 3861 3010 Defeatable S1 type 3729 7540
5 Black
142F 2111 I-0 200 mm
4P 3861 6010 4, 4X 7.9 inches
Black Black 142H 6111 1400 1020
3629 7910 I-0
2P 3861 2020 4, 4X Defeatable 320 mm 3898 2020
142D 2111 Red / yellow 12.6 inches
200 A I - 0 4, 4X
J 3P 3861 3020 1400 1032 3898 3020
Black 142I 6111
6 1 contact type
I - 0 - Test
4P 3861 6020 NC 3898 4020
4, 4X Defeatable
3999 0701
142D 2115 1 contact type
2P 3861 2038 NO 3898 2038
400 A 3999 0702
J 3P 3861 3038 3729 7544 3898 3038
7
4P 3861 6038 3898 4038
2P 3850 2060
600 A
J 3P 3850 3060 S3 type S3 type
8 Black 200 mm 2P
4P 3850 6060 I-0 7.9 inches 3898 2080
Black 1, 3R, 12 1400 1220 3P
3729 7552
3859 6011 Defeatable 3898 3080
2P 3850 2080 143F 3111 320 mm 4P
800 A 4, 4X Defeatable 12.6 inches 3898 4080
L 3P 3850 3080 143D 3111 1400 1232
8
4P 3850 6080
NFPA79 accessories
Flange handle for flange operation
Use
Meets both UL508A and NFPA79 requirements.
The handle will operate the switch by cable or rod.
sirco_246_a_1_cat
Rating (A) Type Nema type Reference
30 200 Standard handle 1, 3, 3R, 4, 12 3729 9002(1)
30 200 Chrome plated handle 1, 3, 3R, 4, 4X, 12 3729 9003(1)
(1) Defeatable handle.
Cable operator
Use
Link between the flange handle and the switch, please order the flange handle,
sirco_247_a_1_cat
the mechanism and a cable length of your choice.
ul_042_b_1
120 3000 3729 9994
Rod operator
Use
Link between the flange handle and the switch. The rod flange is an
economical solution, please order the flange handle and a rod kit.
ul_043_a
Rating 30 ... 200 A
For enclosure depth (inches) For enclosure depth (mm) Reference
8 24 203 613 3729 9904
Accessories
Direct handle
acces_147_a_2_cat
600 ... 800 Black J/L 2 3859 6011
acces_261_a
Fig.1
Fig. 2
External handle
Use
The locking function of the front external Opening the door when the switch is in the
handle prevents the user from opening the "ON" position is possible by defeating the
door of the enclosure when the switch is in interlocking function with the use of a tool
acces_263_a_2_cat
the "ON" position, and when the switch is (authorised persons only).
padlocked in the OFF position (S1, S2, S3 The interlocking function is restored when
and S4 type handles only). the door is re-closed.
acces_149_a_2_cat
CD 30 1 S0 type 1, 3R, 12 I-0 Red/Yellow 1494 0111
CD 30 1 S0 type 4, 4X I-0 Black 149D 0111
CD 30 1 S0 type 4, 4X I-0 Red/Yellow 149E 0111
CD 30 60 3/4 S1 type 1, 3R, 12 I-0 Black 141F 2111
CD 30 60 3/4 S1 type 1, 3R, 12 I-0 Red/Yellow 141G 2111 S1 type handle
CD 30 60 3/4 S1 type 4, 4X I-0 Black 141D 2111 141D 2911
CD 30 60 3/4 S1 type 4, 4X I-0 Red/Yellow 141E 2111 141E 2911
CD 30 60 3/4 S1 type 4, 4X I - 0 - Test Black 141D 2115 141D 2915
CD 30 60 3/4 S1 type 4, 4X I - 0 - Test Red/Yellow 141E 2115 141E 2915
acces_164_a_2_cat
60400 5/6/7 S2 type 1, 3R, 12 I-0 Black 142F 2111
60400 5/6/7 S2 type 1, 3R, 12 I-0 Red/Yellow 142G 2111
60400 5/6/7 S2 type 4, 4X I-0 Black 142D 2111 142D 2911
60400 5/6/7 S2 type 4, 4X I-0 Red/Yellow 142E 2111 142E 2911
60400 5/6/7 S2 type 4, 4X I - 0 - Test Black 142D 2115 142D 2915 S2 type handle
60400 5/6/7 S2 type 4, 4X I - 0 - Test Red/Yellow 142E 2115 142E 2915
600800 8 S3 type 1, 3R, 12 I-0 Black 143F 3111
600800 8 S3 type 1, 3R, 12 I-0 Red/Yellow 143G 3111
600800 8 S3 type 4, 4X I-0 Black 143D 3111 143D 3911
600800 8 S3 type 4, 4X I-0 Red/Yellow 143E 3111 143E 3911
acces_187_a_1_cat
Handle colour Pack qty External degree of protection (IP) Reference
Black 10 IP65 1493 0000
acces_198_a_1_cat
Handle colour Pack qty Handle Reference
Light grey 50 S2, S3 type 1401 0001
Dark grey 50 S2, S3 type 1401 0011
Light grey 50 S4 type 1401 0031
Dark grey 50 S4 type 1401 0041
acces_145_b_1_cat
- 7.9 in / 200 mm,
- 12.6 in / 320 mm,
- 15.7 in / 400 mm.
acces_369_a_1_cat
CD 30 4.02 ... 14.37 102 ... 365 S0-type 12.6 320 1405 0632
CD 30 4.02 ... 17.52 102 ... 445 S0-type 15.7 400 1405 0640
CD 30 4.02 ... 9.65 102 ... 245 S1 type 7.9 200 1401 0520
CD 30 4.02 ... 14.37 102 ... 365 S1 type 12.6 320 1401 0532
CD 30 4.02 ... 17.52 102 ... 445 S1 type 15.7 400 1401 0540
30 ... 100 5.3 ... 9.06 135 ... 230 S2, S3 Type 7.9 200 1400 1020
200 5.7 ... 9.06 145 ... 230 S2, S3 Type 7.9 200 1400 1020
400 7.87 ... 10.24 200 ... 260 S2, S3 Type 7.9 200 1400 1020
30 ... 100 5.3 ... 13.78 135 ... 350 S2, S3 Type 12.6 320 1400 1032
200 5.7 ... 13.78 145 ... 350 S2, S3 Type 12.6 320 1400 1032
acces_202_a_1_cat
400 7.87 ... 14.96 200 ... 380 S2, S3 Type 12.6 320 1400 1032
30 ... 100 5.3 ... 16.93 135 ... 430 S2, S3 Type 15.7 400 1400 1040
200 5.7 ... 16.93 145 ... 430 S2, S3 Type 15.7 400 1400 1040
400 7.87 ... 18.1 200 ... 460 S2, S3 Type 15.7 400 1400 1040 X
600 ... 800 10.63 ... 11.97 270 ... 304 S3 Type 7.9 200 1400 1220
600 ... 800 10.63 ... 16.69 270 ... 424 S3 Type 12.6 320 1400 1232
600 ... 800 10.63 ... 19.84 270 ... 504 S3 Type 15.7 400 1400 1240
Accessories (continued)
Shaft guide for external handle
Use
This accessory enables handle to engage shaft with a misalignment of up to 15 mm.
Required for a shaft length over 400 mm for S1 to S3 handles and for a shaft lenght
from 320 mm for S0 handle.
acces_260_a_2_cat
Description Reference
Shaft guide for S1 to S3 handles 1429 0000
Shaft guide for S0 handle 1419 0000
acces_056_a_1_cat
HMSDQKNBJDC "R
- For CD 30A/CC, a maximum of 4 ACs
(8 with an additional holder),
- For CD 30A/J, maximum 2 ACs
(6 with an additional holder),
- For 30 to 200A/J, maximum 4 ACs,
- For 400 to 800A/L, maximum 8 ACs.
NO auxiliary contacts
Rating (A) Number of contacts Reference
CD 30 800 1 3999 0701
acces_043_a_1_x_cat
NC auxiliary contacts
A
Rating (A) Number of contacts Reference
B
CD 30 800 1 3999 0702
@MC.-RHFM@KKDCAXSN-.
-"
auxiliary contacts.
Terminal shrouds
Use
Top or bottom protection against direct contact with terminals or connection parts.
2 sets required to fully shroud both line and load terminals.
Front and side operation
Rating (A) No. of poles Reference(1)
30 100 2/3/4 P as standard
200 2P 3898 2020
200 3P 3898 3020
fuser_314_a_1_cat
200 4P 3898 4020
400 2P 3898 2038
400 3P 3898 3038
400 4P 3898 4038
600 800 2P 3898 2080
600 800 3P 3898 3080
600 800 4P 3898 4080
(1) Top or bottom.
Terminals lugs
Use
Connection of cables to the terminals.
Rating (A) Wires range No wires per lug Lugs per kit Wires Reference
CD 30 #14 - #10 1 Cu as standard
30 #14 - #10 1 Cu as standard
30 60 #10 - #6 1 Cu as standard
ul_032_a
60 100 #12 - #1 1 Cu as standard
200 #6 - 300MCM 1 2 Cu / Al 3954 2020
200 #6 - 300MCM 1 3 Cu / Al 3954 3020
200 #6 - 300MCM 1 4 Cu / Al 3954 4020
400 #2 - 600MCM 1 2 Cu / Al 3954 2040
400 #2 - 600MCM 1 3 Cu / Al 3954 3040
400 #2 - 600MCM 1 4 Cu / Al 3954 4040
400 2 x (#6 - 350 MCM) 2 2 Cu / Al 3954 2041
400 2 x (#6 - 350 MCM) 2 3 Cu / Al 3954 3041
400 2 x (#6 - 350 MCM) 2 4 Cu / Al 3954 4041
600 2 x (#2 - 600MCM) 1 2 Cu / Al 3954 2060
600 2 x (#2 - 600MCM) 2 3 Cu / Al 3954 3060
600 2 x (#2 - 600MCM) 2 4 Cu / Al 3954 4060
Solid links
Rating (A) Fuses No of links per kit Reference
60 J 3 3799 9006
60 J 4 3799 8006
100 J 3 3799 9010
fuser-ul_013_a_1_cat
Mechanical endurance
Endurance (number of operating cycles) 10 000 10 000 10 000 10 000 10 000 10 000 8 000 6 000 5 000 5 000
Connection
Min. connection cross-section/ (mm2)(2) #14 #14 #10 #10 #12 #12 #6 #2 or 2 x #6 2 x #2 2 x #2
2 (2) 600MCM or
Max. connection cross-section/ (mm ) #10 #10 #6 #6 #1 #1 300MCM 2 x 600MCM 2 x 600MCM
2 x 350MCM
Dimensions (in/mm)
FUSERBLOC CD 30 A / CC - Frame size 1
H
F
Z
J J1
N1
AA
fuser_655_a_1_x_cat
H1
H F
Z J J1
N1
fuser_656_a_1_x_cat
AA
N
Switch body Switch mounting Connection
Rating (A) / Fuse Unit F H J J1 N N1 AA Z
in 4.13 3.89 1.47 0.59 3.30 1 4.56 1.12
CD 30 A / J
mm 105 99 37.5 15 84 25.5 116 28.5
5.87
149.3 4.84
1.41 123
1.46 1.41
36 37.2 36
fuser-ul_001_a_1_x_cat
102.1
5.35
4.02
136
Dimensions (continued)
FUSERBLOC 60 to 100 A / J - Frame size 5
5.87 4.81
149.3 122.2
1.41
1.41 1.46 36
36 37.2
fuser-ul_002_a_1_x_cat
7.32
6.77
5.23
186
172
133
fuser-ul_003_a_1_x_cat
11.46
291.3
165.2
134.2
6.50
5.28
7.67
195
1.41
36
5.11 1.96
130 50
Note for width:
For 2 pole device decrease overall width by 1.96/50mm.
For 4 pole device increase overall width by 1.96/50mm.
7.5
7
180
198 (3P) - 264 (4P)
111.1
75
101.25
fuser-ul_004_c_1_x_cat
202.5
240
194
209
390
101.25
24.9
75
3.12 0.43
79.5 11
0.27
7
fix 9.84
fix 250
10.23
11.81
126.5
300
260
18.54
3.54
471
5
90
fuser_631_b_1_gb_cat
0.27
7
11.81
300
0.27
3.36
85.5
7 0.51 0.35
13 9
2.32
59 2
14.96 51 3.7 3.7
380 94 94
14.33 (3P) - 18.03 (4P)
Note for width: 364 (3P) - 458 (4P)
For 2 pole device decrease overall 3 pole width by 3.7/94mm.
Dimensions (continued)
FUSERBLOC 30 to 400 A FUSERBLOC 600 to 800 A
Front direct handle Front direct handle
2.36
60
1.57 1.79
40 45.5
sirco-ul_027_a_1_x_cat
7.48
190
5.31
135
sirco_267_b_1_x_cat
3.35
85
External handle dimensions (in / mm)
FUSERBLOC CD 30 A - Frames 1 / 2
Front operation Side operation
Handle type Direction of operation Direction of operation Door drilling
S0 type
With 4 xing screws
3.07 I I
78 40
90 90
3.46
88
47
1.45 0 0
37
28
31
fuser-ul_015_a_1_gb_cat
0.53
13.5
0.88
22.5
FUSERBLOC CD 30 to 60 A - Frames 1 / 2 / 4
Front operation Side operation(1)
Handle type Direction of operation Door drilling Direction of operation Door drilling
S1 type
I
I
1.46
9 0 1.46
37 37
90
4 0.27 4 0.27
20
20
47
0.78
47
0.78
3.07
78
0 0
fuser-ul_015_b_1_gb_cat
2.75
65
70
20
20
0.78
0.78
4 0.27 37 4 0.27 37
90
20
20
47
0.78
47
0.78
3.07
78
0
0
65
fuser-ul_016_b_1_gb_cat
20
20
0.78
0.78
4.92
125
4 0.27 37
90
78
20
47
0.78
0
20
0.78
fuser-ul_017_b_1_gb_cat
210
0.55 0.55
14 14
61
2.88
25
38
1.3
35
1
4.7
2 73.15
51 0.53
0.45 2.8 0.63 13.46 0.40
1.52 11.6 71.5 15.88
49.30
10.2
1.94
38.8
3.15
80
sirco_115_b_1_x_cat
sirco-ul_010_a_1_x_cat
sirco-ul_026_a_1_cat
1.19
30.23
sirco_116_b_1_x_cat
1.12
28.6
31.75
11.13
1.25
0.44
1.8
0.25
46
2.87
6.35
73
600 kcmil
300 kcmil 2 x 350 kcmil 2 x 600 kcmil max
Strong points
Large range
rm_061_a_1_cat
RM
32 A rm_062_a_1_cat Conformity to standards
RM and RMS are modular fuse disconnect switches for cylindrical fuses. They provide safety
disconnection and protection against overloads and short-circuits in any low voltage electrical circuit.
- RM: fuse disconnect switches without signalisation (for fuses without striker).
- RMS: fuse disconnect switches with pre-break, position signalisation and blown indication
auxiliary contact.
Advantages
Improved safety Specific format and accessories.
q Omnipolar and simultaneous breaking. q Modular DIN 45 mm cut-out.
q High dielectric strength. Protection IP2X. q Interlocking with accessory available.
References
RM - Device without signalisation
To be ordered To be ordered
No. of poles Reference Reference
in multiples of in multiples of
1 P with 1 AC 6 5702 5011 6 5703 5011
2 P with 2 AC 3 5702 5012 3 5703 5012
3 P with 1 AC 2 5702 5013 2 5703 5013
3 P with 1 AC N 1 5703 5014
3 P + N with 1 AC 1 5702 5014
4 P with 2 AC 1 5703 5016
(1) The signalisation auxiliary contact provides the pre-break, fuse presence and also signals a blown fuse.
Think about it
10x38 RMs equipped with 0.5A gG fuses provide effective protection for voltage inputs and auxiliary
supplies for all our electronic devices (DIRIS, COUNTIS, ISOM, RESYS differential relays, etc.).
Accessories
Auxiliary contact
Use
q Pre-break, presence and fuse blown for RMS 50 and 100:
1 or 2 NO/NC auxiliary contacts
acces_365_a
Connection
acces_366_a
By 6.35 mm fast-on terminal.
Operating
Characteristics current Ie (A)
250 VAC
Rating (A) Contact type AC-13
50 100 NO/NC contact 5
50 100 Two level NO/NC contacts 0.1
acces_367_a
References
NO/NC contact for RMS
Rating (A) Contact(s) Reference
50 1 P with 1 AC 5702 9901
50 3 P with 1 AC 5702 9903
50 3 P with 2 AC 5702 9030
100 1 P with 1 AC 5703 9901
100 3 P with 1 AC 5703 9903
100 3 P with 2 AC 5703 9030
acces_068_a_1_x_cat
Rating (A) Contact(s) Reference
50 1 P with 1 AC 5702 9911 1 4 2
50 3 P with 1 AC 5702 9913
100 1 P with 1 AC 5703 9911
100 3 P with 1 AC 5703 9913
rm_063_a_1
rm_064_a_1
Rating (A) Reference
32 5701 9040
50 5702 9040
100 5703 9040
CLIC !
Dimensions
RM 32 A Single and multipolar RM / RMS 50 A
70 106
52,5 100,7 79,5
58 35 76 53
rm_027_a_1_x_cat
40 17,5 49,5 26,5
rm_047_b_1_x_cat
45
78
40
110
20 6
35,3
40
74,8
49,5
47
49,5
Strong points
Base
Base
size 1
IP2X > High electrical safety.
> Fuse blown detection.
Function
> Different fixing types.
SOCOMEC fuse bases provide fixed, unipolar or multipolar support for knife edge fuses.
Advantages
Conformity to standards
High electrical safety Fuse blown detection
q High dielectric strength. When used with fuses with strikers, it is > IEC 60269-1
q Protection IP2X (standard or optional possible to collect the fuse blow detection
> IEC 60269-2
depending on models). information thanks to an auxiliary contact.
Different fixing types > IEC 60269-2-1
High breaking capacity
Protection against overloads and short- DIN rail or back plate mounting available > NF EN 60269-1
circuits thanks to fuses with a high breaking (depending on models). > NF C 63211
capacity (100 kA rms). > VDE 0636-10
> DIN 43620
Functional diagram
Functional diagram
(for further details see
4 the installation
instructions supplied
with the product).
2
socle_016_c_1_x_cat
5
3
References
Fuse bases for fuses with or without a striker from 160 to 630 (U = 690 V)
Back plate mounted device
Rating 160 A 160 A 250 A 400 A 630 A
Fuse size 00 0 1 2 3
To be ordered
No. of poles Reference Reference Reference Reference Reference
in multiples of
1P 3 6500 1010 6501 1010 6501 1011 6501 1012 6501 1013
3P 1 6500 1030 6501 1030 6501 1031 6501 1032 6501 1033
DIN rail-mounted device
To be ordered
No. of poles Reference Reference Reference Reference Reference
in multiples of
1P 3 6500 1110 6501 1110 6501 1111 6501 1112 6501 1113
3P 1 6500 1130 6501 1130 6501 1131 6501 1132 6501 1133
Options: IP20 kit
No. of poles Reference Reference Reference Reference Reference
1 P (1) 6510 1010 6511 1010 6511 1011 6511 1012 6511 1013
3 P(2) 6510 1030 6511 1030 6511 1031 6511 1032 6511 1033
(1) IP20 single-pole kit consisting of 2 connecting blocks, 2 phase separation shields, 2 terminal shrouds and 1 fuse cover.
(2) IP20 three-pole kit consisting of 2 connecting blocks for the ends, 2 phase separation shields for the ends, 6 terminal shrouds and 3 fuse covers.
Accessories
To be ordered
Description of accessories Reference Reference Reference Reference Reference
in multiples of
Connecting block - set of 1 piece 2 6500 0033 6500 0030 6500 0031 6500 0031 6500 0032
Phase separation shield - set of 1 piece 2 6500 0001 6500 0002 6500 0003 6500 0003 6500 0004
Terminal shrouds - set of 1 piece 6 6500 0010 6500 0011 6500 0012 6500 0013 6500 0014
Fuse cover - set of 1 piece 3 6500 0020 6500 0021 6500 0022 6500 0022 6500 0023
Dimensions
Fuse base 160 A size 00 Fuse base 160 to 630 A size 0, 1, 2 and 3
K K
F I F I C
G 9 18.5 J C G J D
2
D
M
M
P
Q
socle_076_a_1_x_cat
Q
socle_075_a_1_x_cat
N
B
A
E
L
H
N
L
B
A
Rating Fuse
A W C D E F G H I J K L M N O P Q
(A) size
160 00 122 100 37 22 86 59.5 23 114 38.5 85 M8 25 8
160 0 170 150 47 24 122 63 29 74 144 48.5 91.5 185 8 25 7.5 15
250 1 200 175 60 28 148 77.5 35 80 192 66 123 250 10 25 30 10.5 20.5
400 2 225 200 60 32 148 88 35 80 192 66 123 250 12 25 30 10.5 20.5
630 3 240 210 60 38 148 97 35 80 224 82 143 270 12 25 30 10.5 20.5
References
Unipolar fuse bases for fuses with a striker from 160 to 630 A (U = 690 V)
Back plate mounted device without AC
Rating 160 A 250 A 400 A 630 A
Fuse size 0 1 2 3
No. of poles Reference Reference Reference Reference
1P 6501 1010 6501 1011 6501 1012 6501 1013
DIN rail-mounted accessory without AC
No. of poles Reference Reference Reference Reference
1P 6501 1110 6501 1111 6501 1112 6501 1113
Accessories
Presence and fuse blown signalling AC (DDMM)
No. of poles Reference Reference Reference Reference
1P 6500 0040 6500 0041 6500 0042 6500 0043
Characteristics
NO/NC contact
Nominal current In (A) 250 VAC 16 16 16 16
Dimensions
Fuse base 160 to 630 A size 0, 1, 2 and 3
B C
Rating (A) Fuse size A W C
160 0 193 65,5 90
socle_057_a_1_x_cat
250 1 215 76 98
400 2 227 76 102
630 3 235 76 102
A
References
Multipolar fuse bases for fuses with a striker from 160 to 400 A (U = 690 V)
Back plate mounted device with presence and fuse blown signalling AC (DDMM)
Rating 160 A 250 A 400 A
Fuse size 0 1 2
No. of poles Reference Reference Reference
2P 6301 2016 6301 2024 6301 2039
3P 6301 3016 6301 3024 6301 3039
4P 6301 4016 6301 4024 6301 4039
Auxiliary contacts for fuse blown indication
Position AC Reference Reference Reference
1st AC included included included
2nd 3994 1901 3994 1901 3994 1901
Terminal shrouds (1 piece)
No. of poles Reference Reference Reference
2P 3998 2016 3998 2025 3998 2025
3P 3998 3016 3998 3025 3998 3025
4P 3998 4016 3998 4025 3998 4025
Dimensions
Fuse base 160 to 400 A size 0
C1 A
socle_044_a_1_x_cat
7 J1 x. J J1 4
R
J2
x. K
U
B
H
T 4 J3 X
Y P P
Rating
Fuse size A 2p. A 3p. A 4p. W C C1 H J J1 J2 J3 K P R T U X Y
(A)
160 0 111 161 211 162 229 136,5 174 50 60 20,5 5,4 140 50 20 2,5 141 8,5 19,5
250 1 131 191 251 195 251 146 185 60 60 7,5 6,4 162 60 32 2,5 166 11 19,5
400 2 143 209 275 205 260 149 200 66 66 2,5 6,4 172 66 50 3 175 11 20
References
Fuse bases for fuses with or without a striker from 1000 to 2500 A (U = 690 V)
Device without presence and fuse blown signalling (DDMM)
Rating 1000 A 1250 A 2500 A 2500 A 2500 A
Fuse size 4 4 2x4 2 x 4 (S) 6
No. of poles Reference Reference Reference Reference Reference
1P 6431 0004 6431 0005 6431 0006 6431 0007(1)
(1) Without solid link.
Dimensions
Fuse base 1000 to 2500 A size 4 Fuse base 2500 A, size 2 x 4
90 118
145/188* 118
65 125
socle_007_b_1_gb_cat
70
90
socle_006_d_1_x_cat
9
340
25
380
9
25
30 45 30
30
11
25
5 13
40
17
T
20
25 50 10
Y
31
* with fuse blown indicator
Rating (A) Y (mm) T (mm)
1000 25 4
1250 30 9
Fuse base 2500 A, size 2 x 4 (S) Fuse base 2500 A, size 6 (for neutral)
118
298 100
253
181
socle_008_b_1_x_cat
9
socle_024_a_1_x_cat
30
25
30
410
25
150
206
360
9
14
4
50
40
25
50 10
20
15 40 13
36 90 31
References
Unipolar fuse bases for UR fuses
L shape bracket 00/80 (distance between centres 80) 690 VAC 1000 VAC 1400 VAC
Thermal current Ith at 40C Type of fuse Reference Reference Reference
200 00 bolted connection 170A 6080
400 00 bolted connection 170H 1007
Knife-edge fuses /80 (distance between centres 80)
Thermal current Ith at 40C Type of fuse Reference Reference Reference
1250(1) from 1* to 3 170H 3004
(1) For current > 1250 A, please consult us.
Dimensions
Bracket 00/80 - 200 A - 1000 VAC Knife-edge /80 - 1250 A - 1000 VAC
Ref: 170H 1007 Ref.: 170H 3004
M8 80
M8 A-A
M10
M8
50.5
77
40.5
19 6
64
A
27
145 43 A 60
126 205 85
80
150
socle_052_a_1_x_cat
socle_054_a_1_x_cat
25
40
4 x 7 (M6) 25 min. 14
9
M10
M8 110
A-A
M10
M8
77
64
A
27
A 60
205 85
180
socle_053_a_1_x_cat
40
9
M10
Strong points
fusib_134_a_1_cat
fusib_135_a_1_cat
fusib_139_a_1_cat
fusib_142_a_1_cat
> High reliability.
fusib_154_a_1_cat
A1 NIT/NITD > Safety.
A2 TIA/AAO
B2 TF/DD
C1 TM/EF Conformity to standards(1)
D1 TLU/GH
F2 ES/ESD
> IEC 60269-1
> IEC 60269-2
> IEC 60269-2-1
> NF EN 60269-1
Function > NF C 63-210
SOCOMEC industrial fuses protect installations and people against overcurrents for any low > NF C 63211
voltage electrical circuit. > VDE 0636-10
> DIN 43620
(1) Product reference on request.
Advantages
High level performance High reliability
q High breaking capacity 120 kA at 500 V, q Absolute protection over time guaranteed Available on request
80 kA at 690 V. by the simplicity of manufacture and
q High short-cicuit limitation capacity. function (Joule effect). > EDF application:
q Simple, reliable discrimination. T2 fuses, in accordance
Safety with standard HN 63 - S20.
q The energy given off whilst eliminating the > 690 V knife-edge fuses.
fault is contained within the cartridge. > UL and CSA fuses for
North American markets.
References
Distribution industrial fuselinks (type gG)
References (continued)
Distribution industrial fuselinks (type gG)
C1(1) C2(1) C3(1) D1(1) D1(1)
TM / EF TTM / FF TLM / GF TLU / GH TXU / GH
Rating Voltage
(A) (VAC) Reference Voltage (VAC) Reference Voltage (VAC) Reference Voltage (VAC) Reference Voltage (VAC) Reference
355 415 6C10 0355
400 415 6C10 0400
450 550 6C20 0450
500 550 6C20 0500
560 550 6C20 0560
630 550 6C20 0630
710 550 6C30 0710 550 6D10 0710
800 550 6C30 0800 550 6D10 0800
1000 550 6D10 1000
1250 550 6D10 1250
(1) Centre bolted tag type fuselinks.
Accessories
Fuse holders for offset blade type fuselinks
References
Rating Voltage Output
fusib_144_a_1_cat
(A) Size (VAC) Color connection Type Pack qty Reference
32 F1 550 black front/rear 32NNSF 10 5F10 0032
32 F1 550 black front/rear 32NNNSFBS 10 5F10 0132
32 F1 550 black rear/rear 32NNSBS 10 5F10 0232
32 F1 550 white front/rear 32NNSFW 10 5F10 1032
32 F1 550 white front/rear 32NNSFBSW 10 5F10 1132
Voltage: 550 VAC.
32 F1 550 white rear/rear 32NNSBSW 10 5F10 1232
63 F2 550 black front/rear 63ENSF 5 5F20 0063
63 F2 550 black front/rear 63ENSFBS 5 5F20 0163
63 F2 550 black rear/rear 63ENSBS 5 5F20 0263
63 F2 550 white front/rear 63ENSFW 5 5F20 1063
63 F2 550 white front/rear 63ENSFBSW 5 5F20 1163
63 F2 550 white rear/rear 63ENSBSW 5 5F20 1263
Accessories
Rating (A) Size Output connection Type Pack qty Reference
busbar connecting
32 F1 32BCSNNS 1 5F10 0001
systems
busbar connecting
63 F2 63BCSENS 1 5F20 0001
systems
32 F1 solid neutral links 32NNL 1 5F10 0002
63 F2 solid neutral links 63ENL 1 5F20 0002
References
Rating Voltage Output
(A) Size (VAC) Color connection Type Pack qty Reference
32 A1 660 black front/front CM32FC 10 5A10 0032
32 A1 660 white front/front CM32FCW 10 5A10 1032
fusib_143_a_1_cat
32 A2 660 black front/front CM32F 10 5A20 0032
32 A2 660 white front/front CM32FW 10 5A20 1032
63 A3 660 black front/front CM63F 5 5A30 0063
63 A3 660 white front/front CM63FW 5 5A30 1063
100 as A3 660 black front/front CM100F 5 5A30 0100
100 as A3 660 white front/front CM100FW 5 5A30 1100 Voltage: 660 VAC.
Output connection: front / front.
Accessories
Rating (A) Size Output connection Type Pack qty Reference
32 A1 rear connection studs 32BSC 10 5A10 0001
32 A2 rear connection studs 32BS 10 5A20 0001
63 ... 100 A3 rear connection studs 63 / 100BS 5 5A30 0001
32 A1 - A2 lockable safety carrier 32LSC 3 5A20 0002
63 ... 100 A3 lockable safety carrier 63 / 100LSC 3 5A30 0002
32 ... 100 A1 - A3 ganging link pack GLP 1 5A30 0003
32 ... 100 A1 - A3 neon indicator (90 - 660 VAC) NI 3 5A30 0004
32 ... 100 A1 - A3 security clip CMSC 10 5A30 0005
Characteristics
Distribution industrial fuselinks (type gG)
fusib_114_b_1_cat
fusib_116_a_1_cat
fusib_103_c_1_cat
Strong points
gG fuse
from 0.5 to 125 A > High level performances.
> High reliability.
> Improved safety.
aM type fuse
from 6 to 1250 A gG fuse
from 6 to 315 A
Conformity to standards
Function
SOCOMEC industrial fuses protect installations and people from overcurrents for any low
voltage electrical circuit.
Advantages
High level performances Improved safety
q High breaking capacity - 120 kA at The energy released whilst eliminating the fault
5J @S5
(fuse blowing) is contained within the cartridge
q High short-circuit (no degassing).
limitation capacity.
q Simple and reliable discrimination.
High reliability
q Absolute protection over time guaranteed
by the simplicity of manufacture and
function (Joule effect).
q No downgrading of fuse characteristics over
time.
References
gG type fuses (in multiples of 10)
10 x 38 14 x 51 14 x 51 22 x 58 22 x 58
without striker without striker with striker without striker with striker
Voltage Voltage Voltage Voltage Voltage
Rating (A) Reference Reference Reference Reference Reference
(VAC) (VAC) (VAC) (VAC) (VAC)
0.5 500 6012 0000
1 500 6012 0001 6022 0001
2 500 6012 0002 6022 0002 500 6052 0002 6032 0002
4 500 6012 0004 6022 0004 500 6052 0004 6032 0004 6062 0004
6 500 6012 0006 6022 0006 500 6052 0006 6032 0006 6062 0006
500 6012 0008 6022 0008 500 6052 0008 6032 0008 6062 0008
10 500 6012 0010 6022 0010 500 6052 0010 6032 0010 6062 0010
12 500 6012 0012 6022 0012 500 6052 0012 6032 0012 6062 0012
16 500 6012 0016 6022 0016 500 6052 0016 6032 0016 6062 0016
20 500 6012 0020 6022 0020 500 6052 0020 6032 0020 6062 0020
25 500 6012 0025 6022 0025 500 6052 0025 6032 0025 6062 0025
32 400 6012 0032 500 6022 0032 500 6052 0032 6032 0032 6062 0032
40 500 6022 0040 500 6052 0040 6032 0040 6062 0040
50 400 6022 0050 400 6052 0050 6032 0050 6062 0050
63 6032 0063 6062 0063
500 6032 0080 500 6062 0080
100 500 6032 0100 500 6062 0100
125 400 6032 0125 400 6062 0125
Description of accessories
Description of accessories
Reference Reference Reference Reference Reference
Solid cylindrical link 6019 0000 6029 0000 6029 0000 6039 0000 6039 0000
References (continued)
*MHEDDCFDETRDR-'F&SXOD
000/00C 00 0 0 1 1
without striker without striker without striker with striker without striker with striker
(in multiples of 3) (in multiples of 3) (in multiples of 3) (in multiples of 3) (in multiples of 3) (in multiples of 3)
Voltage Voltage Voltage Voltage Voltage Voltage
Rating (A) Reference Reference Reference Reference Reference Reference
(VAC) (VAC) (VAC) (VAC) (VAC) (VAC)
6 500 6600 0006
10 500 6600 0010
16 500 6600 0016 500 6702 0016
20 500 6600 0020 500 6702 0020
25 500 6600 0025 500 6702 0025
32 500 6600 0032 500 6702 0032 6852 0032
40 500 6600 0040 500 6702 0040 6852 0040
50 500 6600 0050 500 6702 0050 6852 0050
63 500 6600 0063 500 6702 0063 6852 0063 500 6712 0063
500 6600 0080 500 6702 0080 6852 0080 500 6712 0080 6862 0080
100 500 6600 0100 500 6702 0100 6852 0100 500 6712 0100 6862 0100
125 500 6692 0125 500 6702 0125 500 6852 0125 500 6712 0125 6862 0125
160 500 6692 0160 500 6702 0160 500 6852 0160 500 6712 0160 6862 0160
200 500 6702 0200 500 6852 0200 500 6712 0200 6862 0200
250 500 6712 0250 500 6862 0250
315 400 6712 0315 500 6862 0315
Description of accessories
2 2 3 3 4 4
without striker with striker without striker with striker without striker with striker
(in multiples of 3) (in multiples of 3) (to this unit) (to this unit) (to this unit) (to this unit)
Voltage Voltage Voltage Voltage Voltage Voltage
Rating (A) Reference Reference Reference Reference Reference Reference
(VAC) (VAC) (VAC) (VAC) (VAC) (VAC)
100 500 6722 0100
125 500 6722 0125 6872 0125
160 500 6722 0160 6872 0160
200 500 6722 0200 6872 0200
250 500 6722 0250 6872 0250
315 500 6722 0315 6872 0315 500 6732 0315 6882 0315 500 6746 0315 500 6896 0315
400 500 6722 0400 500 6872 0400 500 6732 0400 6882 0400 500 6746 0400 500 6896 0400
500 500 6722 0500 500 6872 0500 500 6732 0500 6882 0500 500 6746 0500 500 6896 0500
630 500 6732 0630 500 6882 0630 500 6746 0630 500 6896 0630
500 6732 0800 500 6746 0800 500 6896 0800
500 6746 0900 500 6896 0900
1000 500 6746 1000 500 6896 1000
1250 500 6746 1200 500 6896 1200
Description of accessories
Description of accessories
2 2 3 3 4 4
without striker with striker without striker with striker without striker with striker
(in multiples of 3) (in multiples of 3) (to this unit) (to this unit) (to this unit) (to this unit)
Voltage Voltage Voltage Voltage Voltage Voltage
Rating (A) Reference Reference Reference Reference Reference Reference
(VAC) (VAC) (VAC) (VAC) (VAC) (VAC)
100 500 6723 0100
125 500 6723 0125
160 500 6723 0160 6873 0160
200 500 6723 0200 6873 0200
250 500 6723 0250 6873 0250
315 500 6723 0315 6873 0315 500 6733 0315 6883 0315 500 6747 0315 500 6897 0315
400 500 6723 0400 6873 0400 500 6733 0400 6883 0400 500 6747 0400 500 6897 0400
500 500 6723 0500 500 6873 0500 500 6733 0500 6883 0500 500 6747 0500 500 6897 0500
630 500 6733 0630 500 6883 0630 500 6747 0630 500 6897 0630
500 6747 0800 500 6897 0800
1000 500 6747 1000 500 6897 1000
1250 500 6747 1200 500 6897 1200
Description of accessories
Accessories
Solid cylindrical link
Use
Solid link to be used in conjunction with the neutral pole
of cylindrical fused disconnecting switches.
RHYDRWWW
To be ordered
Rating (A) Size Reference
in multiples of
fusib_123_a_1_cat
32 W 10 6019 0000
50 14 x 51 10 6029 0000
100 W 10 6039 0000
Solid links
Use
Solid link to be used in conjunction with fuse bases or knife-edge
ETRDCCHRBNMMDBSHMFRVHSBGDRFDMDQ@KKXEHSSDCNMSGDMDTSQ@KONKD
6 sizes: 000/00C/00-0-1-2-3-4.
fusib_124_a_1_cat
Rating (A) Size Tightening Reference
160 000/00C/00 elastic 6420 0000
160 0 elastic 6421 0000
315 1 elastic 6421 0001
400 2 elastic 6421 0002
630 3 elastic 6421 0003
1250 4 blocked 6441 0005
Operating handle
Use
fusib_122_a_1_cat
%NQHMRDQSHMF@MCDWSQ@BSHMFJMHEDDCFDETRDRRHYDRSN
Type Reference
Operating handle 6401 0011
Dimensions
Cylindrical fuses (NF)
Without striker - with striker
D
Standard dimensions (mm) as per IEC 60269-2-1
ETRHA>>A>>W>B@S
Size A B C D E
E
W 10.3 10.5
A
14 x 51 14.3 51
7.5
W 22.2 16.2 7.5
C
B
00 15 6 54 30 35 11
D 0 127.5 15 6 40 35 11
F C 1 137.5 20 6 75 52 53 40 11
E 2 152.5 25 6 75 60 61 11
A G 3 152.5 32 6 75 75 76 60 11
4 203 16 150 105 110 11
With striker
A B F G H M2 X
M2 Size C D E I K L M1
maxi mini maxi maxi maxi mini mini
I
ETRHA>>B>>W>B@S
H
0 127.5 15 6 45 35 11.5 14 25 13 11
B
1,5
100 kA cr.
8 1250
7 1000
6 800
5 630
500
4
400
3 315
250
200
2 160
1,5 125
100
80
10 kA 63
50
8 40
7 32
6 25
5 20
4 16
12
3
10
8
Cut-off current kA peak
2 6
1,5 4
8
7
6 1
5
3
catec_112_f_1_gb_cat
1,5
100 A
1,5 3 6 1,5 3 6 1,5 3 6
2 4 8 2 4 8 2 4 8
catec_227_c_1_fr_cat
2 690 V A2t total
107 500 V at rated voltages
7 440 V
5
3
2 A2t of pre-arcing
106
7
5
3
2
I2t (Amperes2 seconds )
105
7
5
3
2
104
7
5
3
2
10 3
catec_225_c_1_gb_cat
7
5
3
2
102
7
5
3
2
101
6 16 25 40 63 100 160 250 400 630 900 1250
10 20 32 50 80 125 200 315 500 800 1000
Fuse In (A)
1000
1250
400
200
250
500
630
800
315
100
125
160
40
20
25
50
63
80
32
10
12
16
2
6
8
1
4000
3000
2000
1500
1000
800
600
400
300
0,5
200
150
100
80
60
40
30
20
15
10
8
6
5
4
3
Pre-arcing time (s)
2
0,25
1,5
1
0,8
0,6
0,4
0,3
0,2
0,15
0,1
catec_111_c_1_gb_cat
0,07
0,05
0,025
0,015
0,01
0,007
0,004
1,5 3 5 7 1,5 3 5 7 1,5 3 5 7 1,5 3 5 7 1,5 3 5 7
2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8
IC (kA)
100
9 1250
8
7 1000
800
6
5 630
425
400
4 355
315
3 250
200
160
2 125
100
80
63
10 50
9
8 40
7 35
32
6
5 25
4 20
16
3 10
6
2
Cut-off current (kA peak)
1
9
8
7
6
5
0,1 Ip (kA)
3 5 7 9 3 5 7 9 3 5 7 9
catec_114_g_1_gb_cat
2 4 6 8 2 4 6 8 2 4 6 8
0,1 1 10 100
2
5 125
7.30
7.6
10
7 160 7.73
5
3 200 12.3 13.7
2
224 14.0 14.0
104
7 250 15.3 17.0
5
3 315 26.0 20.6
catec_226_c_1_gb_cat
2 355 25.2
103 400
26.5 23.5
7
5
425
3
2 500
34
102 630
7
5 70
3
2 1000
1 1250
6 16 25 35 50 80 125 200 315 400 500 800 1250
10 20 32 40 63 100 160 250 355 425 630 1000
16
20
25
32
35
40
50
63
80
6
1000
2
100
2
10
Pre-arcing time (s)
2
1
2
0,1
5
catec_113_d_1_gb_cat
2
0,01
3 5 3 5 3 5 3 5
2 4 6 8 2 4 6 8 2 4 6 8 2 4
10 100 1000 10000
fusib_071_a_2_cat
fusib_066_a_2_cat
fusib_072_a_2_cat
UR type fuses DIN 43620 UR DIN 43653 K/50/80/110 type UR fuses
with or without striker Knife edge fuses Bracket fuse Notched
Strong points
fusib_069_a_2_cat
fusib_070_a_2_cat
fusib_076_a_2_cat
EK/76/86/91 type fuses BK/50/75/80 type fuses T/80 type fuses BT/60 type fuses
Notched Threaded bolted tag Brackets Threaded bolted tag
A complete range
References
690 VAC UR Fuses - Size 14 x 51
14 x 51 UR 14 x 51 UR
without striker with striker
In rms value Pre-arcing I2t when Operating I2t at 690 V Losses at In To be ordered
(A) cold (A2s) rms (A2s) (W) Protection in multiples of Reference Reference
5 1.6 11 1.5 aR 10 170N 1405
10 3.6 38.5 4 aR 10 170N 1410 170L 1410
15 8.6 70 5.5 aR 10 170N 1415 170L 1415
20 26 230 6 aR 10 170N 1420 170L 1420
25 46.5 375 7 aR 10 170N 1425 170L 1425
32 68 600 7.6 aR 10 170N 1432 170L 1432
40 84 750 8 aR 10 170N 1440 170L 1440
50 200 1800 9 aR 10 170N 1450 170L 1450
Description of accessories
Reference Reference
Fuse combination switch recommended (see page 188) FUSERBLOC FUSERBLOC
Fuse holder recommended (see page 262) RM 50 RMS 50
Description of accessories
Reference Reference
Fuse combination switch recommended (see page 188) FUSERBLOC FUSERBLOC
Fuse holder recommended (see page 262) RM 100 RMS 100
References (continued)
690 VAC UR fuses - Size 0000
DIN 43653
Brackets(1)(2)
In rms value (A) Pre-arcing I2t when cold (As) Operating I2t at 1250 V rms (A2s) Losses at In (W) Protection Reference
10 3.8 25.5 3.5 gR 170M 0158
16 8.5 56.5 4.5 gR 170M 0159
20 15 105 5 gR 170M 0160
25 23.5 160 8 gR 170M 0161
32 43.5 290 9 gR 170M 0162
40 77.5 515 11 gR 170M 0163
50 135 915 12 aR 170M 0164
63 260 1750 13 aR 170M 0165
80 485 3250 17 aR 170M 0166
100 860 5700 18 aR 170M 0167
(1) UL / CSA.
(2) Without striker.
(3) With striker.
Description of accessories
Reference Reference
(1)
Fuse base recommended 170H 1007
(1) Direct mounting on busbar.
Description of accessories
Description of accessories
Reference Reference
Fuse blown auxiliary contact 170H 0235 170H 0235
(1)
Fuse base recommended 170H 1007
(1) Direct mounting on busbar.
Description of accessories
Reference
Fuse blown auxiliary contact 170H 0236
Fuse base recommended 6501 1010(1)
Fuse combination switch recommended (see page 188) FUSERBLOC
References (continued)
690 VAC UR fuses - Size 1*
BK/50
K/80 K/110 EK/76 Threaded bolted
Notched Notched Notched tag
In rms Pre-arcing I2t Operating I2t Losses
value (A) when cold (As) at 660 V rms (A2s) at In (W) Protection Reference Reference Reference Reference
40 40 270 9 aR 170M 3108(1) 170M 3258(1) 170M 3358(1) 170M 3458(1)
50 77 515 11 aR 170M 3109(1) 170M 3259(1) 170M 3359(1) 170M 3459(1)
63 115 770 14 aR 170M 3110(1) 170M 3260(1) 170M 3360(1) 170M 3460(1)
80 185 1250 18 aR 170M 3111(1) 170M 3261(1) 170M 3361(1) 170M 3461(1)
100 360 2 450 21 aR 170M 3112(1) 170M 3262(1) 170M 3362(1) 170M 3462(1)
125 550 3 700 26 aR 170M 3113(1) 170M 3263(1) 170M 3363(1) 170M 3463(1)
160 1100 7 500 30 aR 170M 3114(1) 170M 3264(1) 170M 3364(1) 170M 3464(1)
200 2200 15000 35 aR 170M 3115(1) 170M 3265(1) 170M 3365(1) 170M 3465(1)
250 4200 28500 40 aR 170M 3116(1) 170M 3266(1) 170M 3366(1) 170M 3466(1)
315 7000 46500 50 aR 170M 3117(1) 170M 3267(1) 170M 3367(1) 170M 3467(1)
350 10000 68500 55 aR 170M 3118(1) 170M 3268(1) 170M 3368(1) 170M 3468(1)
400 15000 105000 60 aR 170M 3119(1) 170M 3269(1) 170M 3369(1) 170M 3469(1)
450 21000 140000 65 aR 170M 3120(1) 170M 3270(1) 170M 3370(1) 170M 3470(1)
500 27000 180000 70 aR 170M 3121(1) 170M 3271(1) 170M 3371(1) 170M 3471(1)
550 34000 230000 75 aR 170M 3122(1) 170M 3272(1) 170M 3472(1)
630 48500 325000 80 aR 170M 3123(1) 170M 3273(1) 170M 3473(1)
(1) UL / CSA.
Description of accessories
Reference Reference Reference Reference
Fuse blown auxiliary contact 170H 0069 170H 0069 170H 0069 170H 0069
Fuse base recommended 170H 3004 170H 3006 170A 0601(1) (2)
Description of accessories
Description of accessories
Fuse combination switch recommended (see page 188) FUSERBLOC FUSERBLOC FUSERBLOC
(1) Single-pole base 400 A Size 2 (see page 266). (2) Imax = 400 A. (3) Direct mounting on busbar.
Description of accessories
Fuse combination switch recommended (see page 188) FUSERBLOC FUSERBLOC FUSERBLOC
(1) Single-pole base 630 A Size 3 (see page 266). (2) Imax = 710 A. (3) Direct mounting on busbar.
References (continued)
1250 VAC UR fuses - Size 1*
K/110 BK/75 BK/80
Brackets(1) Threaded bolted tag(1) Threaded bolted tag(1)
In rms value Pre-arcing I2t Operating I2t Losses at
(A) when cold (As) @S5QLR 2s) In (W) Protection Reference Reference Reference
50 135 1 100 15 aR 170M 3238 170M 3388 170M 3438
63 215 1 750 20 aR 170M 3239 170M 3389 170M 3439
80 420 3 350 25 aR 170M 3240 170M 3390 170M 3440
100 750 5 950 30 aR 170M 3241 170M 3391 170M 3441
125 1 450 11 500 35 aR 170M 3242 170M 3392 170M 3442
160 2 600 21 000 40 aR 170M 3243 170M 3393 170M 3443
200 5 150 41 000 45 aR 170M 3244 170M 3394 170M 3444
250 9 200 73 000 55 aR 170M 3245 170M 3395 170M 3445
315 18 500 150 000 60 aR 170M 3246 170M 3396 170M 3446
350 27 000 220 000 65 aR 170M 3247 170M 3397 170M 3447
400 53 000 335 000 70 aR 170M 3248 170M 3448
(1) UL.
Description of accessories
Description of accessories
Description of accessories
Description of accessories
Accessories
Fuse blown auxiliary contact
Connection
6.3 x 0.8 mm fast-on connection.
Electronics principle
An auxiliary contact detects if a fuse has blown.
fusib_051_a_1_cat
Electrical characteristics
Voltage (VAC) Nominal current (A)
250 2
Size A W C D E
14 x 51 51 11 4 59 14.3
B
A 22 x 58 58 15 4 66 22.2
D
Size A W C D E F G H K
B 0000 54 100 78 19 18 17 8 1.5
G C 000 54 100 78 40 21 20 51 8 2
00 54 100 78 51 30 28 67 10 2
H
E
B
fusib_021_b_1_x_cat
G C Size A W C E F G H I K
0000 54 78 65 18 13 19 7 10 1.5
H
00 54 95 70 36 32 23 9 10 2
E
I
DIN 43620
A
Size A W C D E F G
G
000 54 79 48 21 35 6 15
fusib_022_c_1_x_cat
0 68 125 60 35 35 6 15
C
E B 1* 71 135 58 45 40 6 20
2 72 150 71 55 48 6 26
F
3 72 150 88 76 60 6 33
D
BT/60
64
54
16
M8
30
6
fusib_023_b_1_x_cat
48
62
1 50 108 78 69 53 6 25 11
H
2 50 108 78 77 61 6 25 11
D1 I
3 51 109 78 92 76 6 30 11
E B
K/110
G
Size A W C D1 E G H I
E
1* 50 134 108 59 45 6 22 11
1 50 138 108 69 53 6 25 11
2 50 138 108 77 61 6 25 11
3 51 139 108 92 76 6 30 11
1* 50 102 76 59 45 6 18 9 13
1 50 111 86 69 53 6 25 11 11
H
2 50 126 91 77 61 6 30 13 12
D I 3 51 126 91 92 76 6 36 13 13
J E B
G
E
BK/50
A
fusib_030_b_1_x_cat
Size A W D E F G H
H
F
1* 50 51 59 45 M8 5 17
1 50 51 59 53 M8 8 20
G
E 2 50 51(1) 77 61 M10 10 24
B
3 51 53(2) 92 76 M12 10 30
(1) B = 65 mm for ratings 1100 to 1250 A.
D
I 1 80 138 108 69 53 6 25 11
D1
2 80 138 108 77 61 6 25 11
E B
3 81 139 108 92 76 6 30 11
G
E
2 74 75 77 61 M10 10 24
G 3 74 76 92 76 M12 10 30
E B
BK/80
Size A W D E F G H
D
1* 80 81 59 45 M8 5 17
E
1 80 81 69 53 M8 8 20
2 80 81 77 61 M10 10 24
3 81 83 92 76 M12 10 30
fusib-pv_018_a_1_cat
fusib-pv_021_a_1_cat
fusib_013_a_1_cat
fusib_026_a_1_cat
Strong points
When to protect
A PV string requires an over-current protection when its own maximum admissible reverse
current characteristic (Irm) is less than the current generated by the rest of the installation
(current generated by the "Nc-1" other strings).
How to protect
The overload protection is to be applied at each of the two polarities, regardless of whether the
DC installation is earthed or not.
q Melting and reliably clearing the fault before the PV modules are damaged by the reverse current.
In < IRM
PV panels
- -
+ + +
+ + +
- -
- -
Fuse Fuse
protection Level 1 protection
(10x38 (10x38 Level 1
Junction box
and RM) and RM) Junction box
fusib_179_a_1_gb_cat
Disconnect Disconnect
switch switch
- -
+
+
Fuse
protection
(NH and Level 2
bases) Junction box
Disconnect
switch
-
+
Surge arrester
Inverter
References
gPV cylindrical Fuses
10 x 38 14 x 51
Rating Rated voltage Dissipated power
Breaking capacity Reference Reference
(A) U DC (V) W@ In W @ 0.8 In
1 1000 0.76 0.43 30 kA 60PV 0001
2 1000 1.54 0.84 30 kA 60PV 0002
3 1000 1.35 0.74 30 kA 60PV 0003
4 1000 1.84 1.08 30 kA 60PV 0004
6 1000 2.50 1.40 30 kA 60PV 0006
8 1000 2.57 1.47 30 kA 60PV 0008
10 1000 2.58 1.51 30 kA 60PV 0010
12 1000 2.61 1.42 30 kA 60PV 0012
15 1000 2.44 1.08 30 kA 60PV 0015
16 1000 2.70 1.56 30 kA 60PV 0016
20 1000 2.99 1.75 30 kA 60PV 0020
25 1000 5.1 2.7 10 kA 60PV 0C25
32 1000 6.2 3.3 10 kA 60PV 0C25
Size Striker A W C
10 x 38 without 10.3 38 10.5
A
C
B
W C G
Size Striker
maxi maxi maxi maxi
G
20A
1A
2A
3A
4A
6A
8A
10000
1000
100
Prearcing time (s)
10
10x38 gPV
0.1
fusib-pv_002_a_1_gb_cat
0.01
0.001
1 10 100 1000
25A
32A
10000
1000
100
Prearcing time (s)
10
14x51 gPV
1
0.1
fusib-pv_003_b_1_gb_cat
0.01
0.001
1 10 100 1000
160A
125A
32A
40A
50A
63A
80A
10000
1000
100
Prearcing time (s)
10
NH1 gPV
0.1
fusib-pv_004_b_1_gb_cat
0.01
0.001
10 100 1 000 10 000
200A
315A
250A
10000
1000
100
Prearcing time (s)
10
2XL gPV
1
0.1
fusib-pv_005_b_1_gb_cat
0.01
0.001
10 100 1 000 10 000
Time-current characteristics
350A
500A
630A
400A
10000
1000
100
Prearcing time (s)
10
3L gPV
0.1
fusib-pv_006_b_1_gb_cat
0.01
0.001
10 100 1 000 10 000
Strong points
rm-pv_0045_a_1_cat
rm-pv_004_a_1_cat
RM PV 10x38 RM PV 10x38
Conformity to standards
32 A 50 A
> IEC 60947-3
> IEC 60269
> NF EN 60269-1
> VDE 0636-10
> DIN 43620
Function
RM PV are modular fuse disconnect switches for cylindrical gPV fuses. They provide safety
disconnection and protection against overcurrents in any low DC voltage photovoltaic applications.
RM are fuse disconnect switches with or without light indicators for fuses without striker.
Advantages
Improved safety Specific format and accessories.
q Rated voltage of 1000 VDC. q Modular DIN 45 mm cut-out.
q Self-extinguishing thermoplastic material. q Interlocking with accessory available.
q Protection IP2X.
References
RM PV
32 A 50 A
10 x 38 14 x 51
No. of poles Reference Reference
56DC 0015 56PV 1401
1 P with signalling 56PV 0L15
)XVHUDWLQJ
Fuse rating (A) 1 20 25 32
Power
Rated dissipated power (W) 3 5
'HVLJQFXUUHQWGHUDWLQJFRHIILFLHQWIRU1SROHVLGHE\VLGH
N=13 1 1
N=46 0.8 0.8
N=79 0.7 0.7
- 0.6 0.6
Connection
Minimum Cu cable cross-section (mm2) 0.75 1.5
Maximum Cu rigid cable cross-section (mm) 10 35
Tightening torque (Nm) 2.5 2.5 3
0HFKDQLFDOFKDUDFWHULVWLFV
Weight of 1 P (kg) 0.1 0, 15
Dimensions
RM PV 10 x 38 RM PV 14 x 51
100.7
79.5 76
61 49.5
56 17.5
rm-pv_002_a_1_x_cat
rm-pv_003_a_1_x_cat
110
78
45
45
2.5
16.5
3.2
35.3
10 43
49.5 26.5
Strong points
socle-pv_004_a_1_cat
Conformity to standards
Function
SOCOMEC fuse bases provide fixed, unipolar or multipolar support for knife edge fuses
dedicated to PV applications.
Advantages
Improved safety Fuse blown indication
q Rated voltage of 1000 VDC. Possibility to collect the fuse blown indication
q Self-extinguishing thermoplastic material. (Please see section PV fuses).
q Kit IP2X (depending on models).
Different fixing types
Product dedicated to PV applications. DIN rail or back plate mounting available
Protection against reverse currents thanks to (depending on models).
gPV fuses dedicated to PV applications.
References
Back plate mounted device
Rating 30-160 A 200-355 A 400-600 A
Fuse size NH1 2XL 3L
No. of poles Reference Reference Reference
1P 65PV 1011 65PV 1112 65PV 1113
Dimensions
Fuse bases 30 to 160 A - NH1 size Fuse bases 200 to 600 A - 2XL and 3L sizes
K
C
F C
G D
M
M
P
P
H
B
A
socle-pv_005_a_1_x_cat
socle-pv_001_a_1_x_cat
Q
H
N
B
A
E
L
O
O
D G
F
K
Rating Fuse
A W C D E F G H K L M N O P Q
(A) size
30 160 NH1 200 175 60 28 148 77.5 35 80 123 250 M10 25 30 10.5 20.5
200 355 2XL 287 257 64 30 - 100 37 140 103 - M10 17.5 30 10.5 -
400 600 3L 307 270 68 40 - 103 38 140 - - M12 25 30 10.5 -
Enclosed
ATyS M
p. 630
ATyS M 6s ATyS M 6
p. 366 p. 366
SIRCOVER UL
ATyS C30 / C40 p. 350
p. 404
Photovoltaic applications
SIRCOVER PV
200 to 630 A
p. 365
innovates to ensure ever more efficient (up to 3200 A), our standard range department will study and define your
continuity in electrical distribution. of changeover switches covers most
switches
O
I
II
GE
O O
I I
II II
O
I
II
U
P
loads loads
S
S
atys_844_a_gb
atys_846_a_gb
Critical Critical
atys_845_a
loads loads
Tower/building application
All our changeover switches are From 40 to 3200 A, our ATS Bypass The experience we have
available in enclosed versions. solution enables the automatic gained from different
changeover switch to be completely projects has led us to
isolated while guaranteeing the continuity develop numerous special
of the installation's power supply. products (make-before-break contact
or mixed pole motorised changeover
switches, specific software, etc.).
Please contact us if you have any
specialist requirements.
ATYS-P 001 A
ATyS S range from 40 to 160 A
Back-to-back
configuration
from 40 to 125 A
ATYSM 007 A
ATYS-S 018 A
ATyS S ATyS Sd ATyS M 3s ATyS M 6s ATyS M 6e ATyS ATyS d ATyS t ATyS g ATyS p
Switching applications Switching applications for Any switching application
with Genset(s) industrial or office buildings with Transformers and/or Gensets
Motorised automatic or remote controlled version
Remotely controlled (RTSE)
Automatic (ATSE)
Dual power supply
Integrated
Automatic controller switching functionalities
Not integrated
Transformer/Transformer application
Transformer/Genset application
Specific functionalities
On load and off load tests (1)
Programming of genset startup
Power management
Communication options
Integrated webserver option
(1) Test on load only.
How many
poles ?
Changeover
switches
Number of poles
3P
4P
Switch operation
I-0-II
I-I+II-II
Bypass
Indication of breaking
Positive break indication
Visible contacts
Operating handle
Front direct/external operation
Door mountable switch
b
(1) Depending on the version. From 125 to 3200A for SIRCOVER I-0-II; from 125 to 1800A for SIRCOVER I-I+II-II and from 125 to 1600A for SIRCOVER Bypass.
What kind
What kind of
of breaking
operations ?
indication ?
Type of transfer
Manual emergency transfer using handle
Remote controlled transfer through volt-free contacts (RTSE)
Automatic transfer (ATSE)
Number of poles
b3
3
b3
ATyS S range: back to back products ATyS range: back to back products
40 to 100 A 125 to 3200 A
new new new new new n ew new
como_178_a_1
Strong points
COMO C COMO C > High number of operations.
I-I+II-II 4P 63 A I-0-II 3P 25 A
> Flexibility.
> Pre-installed bridging bars.
> Compact Design.
Function
COMO C are manual multipolar changeover switches with positive break indication. They Conformity to standards
provide changeover, source inversion or switching under load between two low voltage power
circuits, as well as their safety isolation. > IEC 60947-3
Configurations
1
como_168_b_1_x_cat
4
Functional diagram (for further details see the installation
instructions supplied with the product).
1. IP54 handle.
5
2. Enclosure door.
3. Door interlocking mechanism with shaft.
4. Switch body
5. DIN rail mounting device.
6. Back plate mounting device.
References
Accessories
IP54 handle
Padlockable handle
Rating (A) Handle colour Reference
25 40 Black/Grey 4259 1042
25 40 Red/Yellow 4259 1043
acces_110_a_1_cat
63 100 Black/Grey 4259 1082
63 100 Red/Yellow 4259 1083
Non-padlockable handle
Rating (A) Switching type Reference
25 I - II 4259 2022
25 I - 0 - II and Bypass 4259 3022
25 I - I+II - II 4259 4022
4259 2042
acces_142_b_1_cat
40 I - II
40 I - 0 - II and Bypass 4259 3042
40 I - I+II - II 4259 4042
63 100 I - II 4259 2082
63 100 I - 0 - II and Bypass 4259 3082
63 100 I - I+II - II 4259 4082
acces_072_a_1_cat
Other lengths: Please consult us.
Rating (A) Length (mm) Reference
25 40 200 mm 4259 5042
63 100 200 mm 4259 5082
Dimensions
COMO C 25 A
Direct operation front mounting Direct operation rear mounting Door interlocked external operation
10 10 10
36 10 10 14.3 10
como_113_e_1_x_cat
50
56
64
48
64
48
B
B
A
A
A
B
12.5 36
L 48 12.5 48 75 min. 10
10
L L
A. 1st auxiliary contact
B. 2nd auxiliary contact
COMO C 40 A
Direct operation front mounting Direct operation rear mounting Door interlocked external operation
14.3 10 14.3 10 10
36 18 18 18
como_114_g_1_x_cat
50
56
64
64
B
B
A
A
L 60 10 60 75 min. 10
L
48 48
L
A. 1st auxiliary contact
B. 2nd auxiliary contact
COMO C 63 to 100 A
Direct operation front mounting Direct operation rear mounting Door interlocked external operation
10 36
14.5 14.5
10 10
36 18 36 18 18
como_115_g_1_x_cat
75.2
75.2
71
71
A
A
B
L 66 L 10 66 80 min. 10
48 48 L
A. 1st auxiliary contact
B. 2nd auxiliary contact
sircm_192_a_1_cat
Strong points
Conformity to standards
SIRCO M
(((/
Function
SIRCO M are manually operated three or four pole modular switches with positive break indication.
They provide changeover, source inversion or switching under load between two low voltage
power circuits, as well as their safety isolation.
Advantages
Secured breaking. On load switching
SIRCO M switches include contact point The SIRCO M changeover switch comprises
technology and double break per phase as two mechanically interlocked load break
standard, enabling safe, optimal operation of switches which are tested in accordance with
LV electrical circuits. IEC 60947-3. Its AC23 characteristics enable
it to perform on load changeover switching.
Modular device
Thanks to their modular format, SIRCO M
changeover switches can be fixed to a
#(-Q@HK@A@BJOK@SDNQ@LNCTK@QO@MDK
References
External handle External handle Shaft extension
with position 0 with 3 position for external Auxiliary Terminal
Rating (A) No. of poles Switch body Direct handle padlocking padlocking front handle contact shrouds Bridging kit
3P 2230 3002
25 A S00, S000 type
S000 type 150 mm 1P 3P
4P 2230 4002
I - 0 - II 1407 0515 2294 1005(2) 2299 3005
Black IP65 3P 4P
3P 2230 3004 1463 5113(1) 200 mm 2294 3005(2) 2299 4005
40 A 1407 0520
4P 2230 4004 Blue S00 type S01 type
2239 5012 I - 0 - II I - 0 - II 320 mm
Red Black IP65 Black IP65 1407 0532
3P 2230 3006 2239 5013 1473 1113(1) 1403 2813 M type contact
63 A S01 type NO + NC
4P 2230 4006 S01 type 200 mm 1P 3P
2299 0001
I - 0 - II 1404 0520 2294 1009(2) 2299 3009
Black IP65 3P 4P
3P 2230 3008 M type contact
1403 2113(1) 320 mm 2294 3009(2) 2299 4009
2 NO
80 A 1404 0532 2299 0011
4P 2230 4008
3P 2230 3010
S00 type
100 A
150 mm
4P 2230 4010 Blue S00 type 1P
1409 0615
2239 5022 I - 0 - II 2294 1011(2)
200 mm
Red Black IP65 3P
3P 2230 3011 1409 0620
2239 5023 1473 0113 2294 3016(2)
320 mm
125 A
1409 0632
4P 2230 4011
(1) Defeatable handle. OHDBDR%NQTORSQD@LNQCNVMRSQD@LOQNSDBSHNMNMNMDRHCDNESGDBG@MFDNUDQRVHSBG
Accessories
See "SIRCO M switches", page 31.
Dimensions
WR$
Direct front operation for 3/4 pole changeover switches External front operation for 3/4 pole changeover switches
F
J 89
F2
1 1 78 E A B C
X M 52,5
2 2
sircm_182_a_1_x_cat
71
68
45
80
N
G
45
25
6 36 44
8,8 F1 F1 8,8 43 34,7
T T 7,5
52,5
WR$
Direct front operation for 3/4 pole changeover switches External front operation for 3/4 pole changeover switches
84.5
79.6
M 50 E 36
1
13.8
2
71
68
G
N
sircm_183_d_1_x_cat
F1 T 100 6
8.8
79.6
+NB@SHNMENQL@HMONKDor@TWHKH@QXBNMS@BS2DD@BBDRRNQHDRO@FD 34).
/NRHSHNMENQ@TWHKH@QXBNMS@BSNMKXSGHRBNMS@BSHRENQRHFM@KHR@SHNMNMKX
Note: Maximum 4 additional blocks (3 pole changeover can be fitted with either one main pole and one A/C block,
or two A/C blocks per side; 4 pole changeover can be fitted with only one A/C block per side).
Front operation
Handle type Direction of operation Door drilling
90
90
22.5
27
45
22
poign_017_b_1_gb_cat
I II
45 25
3.2
3.2
36 13.5
Front operation
Handle type Direction of operation Door drilling
S01 type 0
Changeover switches IP65 with 4 xing screws
or
I-0-II and I - I+II - II I+II 40
90
47
90
78
poign_019_b_1_gb_cat
I II
28
80
41
37
44
WR$
Front operation
Handle type Direction of operation Door drilling
S00 type
IP55 with 2 xing clips IP65 with 4 xing screws With xing nut
Changeover switches 0
I-0-II and I - I+II - II or 13.5
37 37
I+II 22.5
71 90
90
40
40
3
poign_025_b_1_gb_cat
71
I II
36 27 47
28 28
comut_065_b_1
Strong points
Advantages
Safety isolation Modular device
SIRCO VM1 changeovers enable completely SIRCO VM1 changeover switches offer a
secure switching thanks to positive break range of installation configurations: DIN rail,
indication and double visible breaking. The backplate or modular panel.
user can assess the condition of the device
either during a preventive check or before an Reduced depth
operation. With its side-by-side switch arrangement, the
SIRCO VM1 changeover can be utilised in
panels with a reduced depth.
Configurations
2
comut_021_b_1_x_cat
References
VM1 changeover switches I-0-II
Shaft for external IP20 bridging
Rating (A) No. of poles Switch body Direct handle External handle handle bars (2) Auxiliary contact
3P 4430 3006(1)
63 A
4P 4430 4006(1)
3P 4430 3008(1)
80 A 200 mm 3P
4P 4430 4008(1) Black S1 type
1402 0820 4499 3006
1 auxiliar contact
4439 5012 Black IP65 NO/NC
3P 4430 3010 (1) 320 mm 4P
1413 2113 4439 0001
100 A 1402 0832 4499 4006
(1)
4P 4430 4010
3P 4430 3012
125 A
4P 4430 4012
(1) Available enclosed (see "Enclosed changeover switches" page 600).
(2) IP: protection degree according to IEC 60529 standard.
Accessories
Direct operation handle
Accessories (continued)
Alternative S-type handle cover colours
Use
acces_198_a_1_cat
For single lever type S1 handles. Other colours: Please consult us.
Colour To be ordered in multiples of Reference
Light grey 50 1401 0001
Dark grey 50 1401 0011
acces_187_a_2_cat
To be ordered
Colour External IP(1) Reference
in multiples of
Black 1 IP65 1493 0000
(1) IP : protection degree according to IEC 60529 standard.
acces_146_b_1_cat
- 200 mm,
- 320 mm.
Switching type I - 0 - II
Dimension X
Rating (A) Shaft length (mm) Reference
(mm)
63 125 128 290 200 mm 1402 0820
acces_202_a_1_x_cat
63 125 128 410 320 mm 1402 0832
Switching type I - I + II - II
Dimension X
Rating (A) Shaft length (mm) Reference
(mm)
63 125 128 290 200 mm 1403 0820
63 125 128 410 320 mm 1403 0832 X
Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s(6)
Rated short-time withstand current 0.3s. Icw (kA rms) 4.5 4.5 4.5 4.5
Connection
Minimum Cu cable cross-section (mm2) 4 4 4 4
Maximum Cu cable cross-section (mm2) 50 50 50 50
Tightening torque mini / maxi (Nm) 6 6 6 6
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 10 000 10 000
Weight of 3 P switch (kg) 1.2 1.2 1.4 1.4
Weight of 4 P switch (kg) 1.4 1.4 1.6 1.6
(1) Category with index A = frequent operation - Category with index B = infrequent operation. (5) For a rated operational voltage Ue = 400 VAC.
(2) With terminal shrouds or phase barrier. (6) Value for coordination with any circuit-breaker ensuring tripping in less than 0.3s. For coordi-
(3) 4-pole device with 2 poles in series per polarity. nation with specific circuit-breaker references, higher short-circuit current values are available.
(4) The power value is given for information only, the current values vary from one manufacturer Please consult us.
to another.
Dimensions
63 to 125 A
Direct front operation External front operation
0 1. Max connection
- Rigid: 50 mm2,
90
- Flexible: 35 mm2
90
I
1 2. 6 -sided 5 - Pozidriv no. 1
215
52 slot 4.5 mm.
182.5 19.5 I II
13 6 90.5 3. Bridging bar
75 75 69.5
44 128 mini 44 4. Handle mounting with
90
2 or 4 screws 7 mm.
115.5
= =
105
45
94
0 20 20
comut_013_e_1_x_cat
70
4
89
78
90 3
1414
21 21 21 44.5
2
II 37
svr_099_b_1_cat
SIRCOVER
3200 A
Strong points
Specific features
SIRCOVER AC I-0-II
> On load switching AC-33.
SIRCOVER Bypass
125 A
Conformity to standards
> ,(&
> ,(&
Function
SIRCOVER are manual multipolar changeover switches with positive break indication.
The family includes three ranges:
Approvals and certifications(1)
q SIRCOVER AC for dead time switching (I-0-II),
q SIRCOVER for overlapping contact switching (I-I+II-II), and
q SIRCOVER Bypass. This version is a combination of three interlocked switches enabling use
with 3 + 6 poles or 4 + 8 poles.
(1) Product reference on request.
They provide switching, source inversion and changeover under load for two low voltage power
circuits, as well as their safety isolation by double breaking per pole.
Enclosed solution
q SIRCOVER with overlapping contacts q All SIRCOVER can be utilised with a direct
(I-I+II-II) are 3 or 4 pole devices available front or external operation handle.
from 125 to 1800 A. They are available in a
steel enclosure from 125 to 1600 A.
svr_136_a_1_x_cat
q Copper bar connection kits enable the connection between the two power terminals of the same pole (fig.1 & fig.2) and the bridging of the
poles on the top or bottom side of the switch (fig.3), for ratings 2000, 2500 and 3200 A.
acces_231_a_1_cat
References
SIRCOVER AC I-0-II
Shaft for Auxiliary Terminal Terminal
Rating (A) No. of poles Switch body Direct handle External handle external handle Bridging bars contact shrouds screens
3P 41AC 3013
125 A
4P 41AC 4013
3P 3P
3P 41AC 3016 2694 3014(3)(4) 1509 3012
160 A 4109 0019
4P 4P
4P 41AC 4016
2694 4014(3)(4) 1509 4012
3P 41AC 3020
200 A
4P 41AC 4020
3P 41AC 3025
250 A J2 type S2 type 4109 0025
200 mm
4P 41AC 4025 Blue Black IP55
1400 1020
1122 1111 1421 2113 3P 3P
320 mm
3P 41AC 3031 Red Black IP65
2694 3021(3)(4)
1400 1032(1) 1509 3025
315 A 1123 1111 1423 2113(1) 4P 4P
4P 41AC 4031
2694 4021(3)(4) 1509 4025
4109 0039
3P 41AC 3039
400 A
4P 41AC 4039
3P 41AC 3080
800 A
4P 41AC 4080
4109 0080 3P
3P 41AC 3100 1509 3080(5)
1000 A
4P
4P 41AC 4100
J3 type 1509 4080(5)
3P 41AC 3120 200 mm
Blue S4 type
1250 A 1401 1520 4109 0120
1132 1111 Black IP65
4P 41AC 4120 320 mm
Red 1443 3113
1401 1532(1)
1133 1111
3P 41AC 3160
1600 A
3P
4P 41AC 4160 1509 3160(5)
4109 0160
4P
3P 41AC 3180
1800 A
1509 4160(5)
4P 41AC 4180
3P 41AC 3200
2000 A
4P 41AC 4200 200 mm
2799 3015
3P 41AC 3250 S5 type S5 type 1st contact
320 mm (6)
2500 A Black Black IP65 NO/NC included
2799 3018(1)
4P 41AC 4250 2799 7042 1453 8113 included
450 mm
3P 41AC 3320 2799 3019
3200 A
4P 41AC 4320
(1) Standard.
(2) 2 pieces supplied, one for position I and one for position II.
(3) To fully shroud front, rear, top and bottom 4 references required.
(4) To shroud front switch top and bottom 2 references required.
(5) 2 pieces supplied, one for top side and another for bottom side.
(6) See "Copper bar connection kits" page 335.
SIRCOVER I - I+II - II
Shaft for Auxiliary Terminal Terminal
Rating (A) No. of poles Switch body Direct handle External handle external handle Bridging bar contact shrouds screens
3P 4190 3013(1)
125 A
4P 4190 4013(1)
3P 4190 3016(1) 3P 3P
2694 3014(4)(5) 1509 3012
160 A 4109 0019
4P 4P
4P 4190 4016(1) 2694 4014(4)(5) 1509 4012
3P 4190 3019
200 A
4P 4190 4019
3P 4190 3080(1)
800 A 4109 0080
4P 4190 4080(1) 3P
1509 3080(6)
4P
3P 4190 3120(1) 1509 4080(6)
1250 A 4109 0120
4P 4190 4120(1) 200 mm
S4 type
Black 1401 1520
(2) Black IP65
2799 7052 320 mm
3P 4190 3160(1) 1443 3114(2)
1401 1532(2)
1600 A
4P 4190 4160(1) 3P
1509 3160(6)
4109 0160
4P
3P 4190 3180 1509 4160(6)
1800 A
4P 4190 4180
References (continued)
SIRCOVER Bypass
Switch body Shaft for Auxiliary Terminal Terminal
Rating (A) No. of poles I-0-II Direct handle External handle external handle Bridging bar contact shrouds screens
S2 type
3+6P 4100 7016(1) Black IP55
200 mm 3P 3P
Black 1400 1020 4109 0019 2694 3014(4)(5) 1509 3012
160 A 1421 2113(2)
4199 5012 320 mm 4P 4P
Black IP65
4+8P 4100 9016(1) 1400 1032(2) 2694 4014(4)(5) 1509 4012
1423 2113
Accessories
Direct operation handle
SIRCOVER AC I-0-II
Rating (A) Handle colour Handle type Reference
125 630 Blue J2 type 1122 1111
125 630 Red J2 type 1123 1111
800 1800 Blue J3 type 1132 1111
800 1800 Red J3 type 1133 1111
acces_129_b_1_cat
acces_356_a_1_cat
acces_153_a_2_cat
2000 3200 Black S5 type 2799 7042(1)
SIRCOVER I - I+II - II
Rating (A) Handle colour Handle type Reference
125 630 Black B3 type 4199 5012
800 1800 Black C1 type 2799 7052
SIRCOVER Bypass
Rating (A) Handle colour Handle type Reference J2 type handle C1 type handle
125 200 Black B3 type 4199 5012
C2 type handle
250 630 Black C1 type 2799 7052
800 1600 Black C2 type 2799 7012(1)
(1) Double lever handle
acces_286_a_1_cat
2000 3200 I - 0 - II IP65 S5 type 1453 8113(2)
acces_152_a_2_cat
acces_151_a_1_cat
To be ordered
Colour in multiples of Handle Reference
Light grey 50 S2, S3 type 1401 0001
Dark grey 50 S2, S3 type 1401 0011
Light grey 50 S4 type 1401 0031
Dark grey 50 S4 type 1401 0041
Accessories (continued)
Shaft guide for external operation
Use Required for shaft lengths over 320 mm.
To guide the shaft extension into the
external handle.
This accessory enables handle to engage
extension shaft with a misalignment of up
acces_260_a_2_cat
to 15 mm.
Description Reference
Shaft guide 1429 0000
acces_369_a_1_cat
- 320 mm,
- 450 mm.
SIRCOVER AC I-0-II and SIRCOVER I-I+II-II
Rating (A) Length (mm) Dimension X (mm) Reference
125 400 200 210 310 1400 1020
125 400 320 210 430 1400 1032
500 630 200 280 390 1400 1020
500 630 320 280 510 1400 1032
acces_144_b_1_cat
800 1800 200 425 577 1401 1520
800 1800 320 425 697 1401 1532
2000 3200 200 653 ... 803 2799 3015
2000 3200 320 653 923 2799 3018
2000 3200 450 653 1053 2799 3019
SIRCOVER Bypass
Rating (A) Length (mm) Dimension X (mm) Reference
125 200 200 320 450 1400 1020
125 200 320 320 570 1400 1032
acces_202_a_1_x_cat
250 400 200 298 420 1401 1520
250 400 320 298 540 1401 1532
500 630 200 417 539 1401 1520
500 ... 630 320 417 659 1401 1532
800 1600 200 550 ... 680 2799 3015
800 1600 320 550 800 2799 3018 X
800 1600 450 550 930 2799 3019
Bridging bars
Use SIRCOVER AC I-0-II SIRCOVER Bypass
For creating a common connection For SIRCOVER Bypass, two sets and SIRCOVER I-I+II-II
between switches I & II, on the top of bridging bars are needed as the
acces_205_a_2_cat
acces_226_b_1_x_cat
terminals of the same pole for 2000 to Bolt sets must be ordered separately.
3200 A ratings (Fig. 1 and Fig 2).
- top or bottom bridging connection (Fig. 3). Further details for these specific
accessories are available in the user guide
downloadable from www.socomec.com.
252
Top or bottom flat connection - Fig. 1 74 74
acces_232_a_1_cat
37 37 60
Quantity to order
Rating (A) Piece per pole(1) Reference
2000 2500 Connection - part A 2 2619 1200
155
129
2000 2500 Bolt set - part B 2 2699 1200
acces_228_b_1_x_cat
the indicated quantities.
acces_233_a_1_cat
3200 Connection - part A included
3200 T piece - part C 2 2629 1200(2)
210
acces_230_b_1_x_cat
Rating (A) Piece per pole(1) Reference
2000 2500 Connection - part A 2 2619 1200 A
2000 2500 Bolt set - part B 2 2699 1200
2000 2500 Bar - part E 1 4109 0250(2)
2000 2500 T piece - part C 1 2629 1200(2)
(1) Example for 3 pole device equipped upstream only: Order 3 times the
indicated quantities.
(2) Bolt set is provided with the accessories.
Auxiliary contact
Use Connection to the control circuit
Pre breaking and signalling of positions I 6.35 mm fast-on terminal.
and II: 1 or 2 NO/NC auxiliary contacts in Electrical characteristics
svr_058_a_1_cat
Characteristics
Operating current Ie (A)
acces_065_a_1_cat
Accessories (continued)
Terminal shrouds
Use Advantage
Protection against direct contact with Perforations allow remote thermographic
terminals or connecting parts. inspection without the need to remove the
shrouds.
acces_206_a_2_cat
No. of
Rating (A) poles Position Reference
125 200 3P top / bottom / front (I) / rear (II) 2694 3014(1)(2)
125 200 4P top / bottom / front (I) / rear (II) 2694 4014(1)(2)
250 400 3P top / bottom / front (I) / rear (II) 2694 3021(1)(2)
250 400 4P top / bottom / front (I) / rear (II) 2694 4021(1)(2)
500 630 3P top / bottom / front (I) / rear (II) 2694 3051(1)(2)
500 630 4P top / bottom / front (I) / rear (II) 2694 4051(1)(2)
(1) To shroud front switch top and bottom 4 references required for a SIRCOVER
and 6 references for a SIRCOVER Bypass.
(2) To shroud front switch top and bottom 2 references required for a SIRCOVER
and a SIRCOVER Bypass.
Terminal screens
Use
Top and bottom protection against direct contact with terminals or
connection parts.
Rating (A) No. of poles Position Reference
acces_207_a_2_cat
125 200 3P top / bottom 1509 3012
125 200 4P top / bottom 1509 4012
250 400 3P top / bottom 1509 3025
250 400 4P top / bottom 1509 4025
500 630 3P top / bottom 1509 3063
500 630 4P top / bottom 1509 4063
800 1250 3P top / bottom 1509 3080
800 1250 4P top / bottom 1509 4080
1600 1800 3P top / bottom 1509 3160
1600 1800 4P top / bottom 1509 4160
2000 3200 3/4P top / bottom included
acces_061_a_1_x_cat
SIRCOVER Bypass Operation Figure Reference
acces_001_a_1_x_cat
125 630 125 200 direct 2 4109 1002(1)
250 630 direct 3 Please consult us
800 1800 800 1600 direct 3 4109 1004(2)
2000 3200 direct 3 4109 2007(2)
125 1800 125 630 external 4 1499 7701(2)
2000 3200 800 1600 external 4 2799 7002(2)
(1) Specific handle included.
(2) This locking facility can be configured by the user in the 3 positions.
Fig. 3 Fig.4
acces_158_a_1_x_cat
800 3200 800 1600 direct 3 Please consult us
q Connection accessories.
q Low level auxiliary contacts.
5DWHGRSHUDWLRQDOFXUUHQWV,H$DFFRUGLQJWR,(&
Rated voltage Utilisation category A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1)
415 VAC AC-31 A / AC-31 B 125 160 200 250 315 400 500 630
415 VAC AC-32 A / AC-32 B 200 315 400 500 500
415 VAC AC-33 A / AC-33 B 200 200 200 400 400
)XVHSURWHFWHGVKRUWFLUFXLWZLWKVWDQGDVSHU,(&DW9$&
Prospective short-circuit current (kA rms) 100 (5) 100 (5) 50 (5) 50 50 50 50 50
Associated fuse rating (A) 125 160 200 250 315 400 500 630
&LUFXLWEUHDNHUSURWHFWHGVKRUWFLUFXLWZLWKVWDQGZLWKDQ\FLUFXLWEUHDNHUWKDWHQVXUHVWULSSLQJLQOHVVWKDQV
Rated short-time withstand current 0.3s Icw (kA rms) 12 (5) 12 (5) 12 (5) 15 15 15 17 17
6KRUWFLUFXLWZLWKVWDQGZLWKRXWSURWHFWLRQDVSHU,(&DW9$&
Rated short-time withstand current 1s Icw (kA rms) 7 (5) 7 (5) 7 (5) 8 8 8 10 10
Rated short-circuit making capacity Icm (kA peak) 11.9 11.9 11.9 22 22 22 17 17
Rated short-time withstand current 60ms Icw
10 (6) 10 (6) 10 (6) 10 12.6
(kA rms) as per IEC 60947-6-1 at 415 VAC
Connection
Minimum Cu cable cross-section (mm2) 35 50 70 95 150 185 240 2 x 150
Minimum Cu busbar cross-section (mm2) 2 x 30 x 5
Maximum Cu cable cross-section (mm2) 50 95 120 150 240 240 2 x 185 2 x 300
Maximum Cu busbar width (mm) 25 25 25 32 32 32 50 50
Tightening torque mini / maxi (Nm) 9/13 9/13 9/13 20/26 20/26 20/26 20/26 20/26
Mechanical characteristics
Durability (number of operating cycles)
Weight of 3 P switch (kg) 2.9 2.9 2.9 3.8 3.9 3.9 8.6 9.1
Weight of 4 P switch (kg) 4.1 4.1 4.1 4.6 4.9 4.9 10.4 11.1
(1) Category with index A = frequent operation - Category with index B = infrequent operation. (4) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s.
(2) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-".4-pole device with 2 pole For coordination with specific circuit-breaker references, higher short-circuit current values are
in series by polarity. available. Please consult us.
(3) The power value is given for information only, the current values vary from one manufacturer (5) Data at 415 VAC
to another. (6) Data at 30 ms
800 to 3200 A
Thermal current Ith at 40C 800 A 1000 A 1250 A 1600 A 1800 A 2000 A 2500 A 3200 A
Rated insulation voltage Ui (V) 1000 1000 1000 1000 1000 1000 1000 1000
Rated impulse withstand voltage Uimp (kV) 12 12 12 12 12 12 12 12
5DWHGRSHUDWLRQDOFXUUHQWV,H$DFFRUGLQJWR,(&
Rated voltage Utilisation category A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1)
415 VAC AC-31 A / AC-31 B 800 1000 1250 1600 1800 2000 2500 3200
415 VAC AC-32 A / AC-32 B 800 1000 1250 1600 1600 2000 2000 2000
415 VAC AC-33 A / AC-33 B 800 800 800 1000 1000 1250 1250 1250
)XVHSURWHFWHGVKRUWFLUFXLWZLWKVWDQGDVSHU,(&DW9$&
Prospective short-circuit current (kA rms) 50 100 100 100 100
Associated fuse rating (A) 800 1000 1250 2 x 800 2 x 800
&LUFXLWEUHDNHUSURWHFWHGVKRUWFLUFXLWZLWKVWDQGZLWKDQ\FLUFXLWEUHDNHUWKDWHQVXUHVWULSSLQJLQOHVVWKDQV
Rated short-time withstand current 0.3s Icw (kA rms) 47 64 64 78 78 78 78 78
6KRUWFLUFXLWZLWKVWDQGZLWKRXWSURWHFWLRQDVSHU,(&DW9$&
Rated short-time withstand current 1s Icw (kA rms) 26 35 35 50 50 50 50 50
Rated short-circuit making capacity Icm (kA peak) 48 73.5 73.5 110 110 110 110 110
Rated short-time withstand current 60ms Icw
16 20 25 32 32 40 50 50
(kA rms) as per IEC 60947-6-1 at 415 VAC
Connection
Minimum Cu cable cross-section (mm2) 2 x 185 2 x 240
Minimum Cu busbar cross-section (mm2) 2 x 40 x 5 2 x 50 x 5 2 x 60 x 5 2 x 80 x 5 3 x 100 x 5 2 x 100 x 10 2 x 100 x 10 2 x 100 x 10
Maximum Cu cable cross-section (mm2) 2 x 300 4 x 185 4 x 185 6 x 185 6 x 185
Maximum Cu busbar width (mm) 63 63 63 100 100 100 100 100
Tightening torque min (Nm) 20/26 20/26 20/26 40/45 40/45 40/45 40/45 40/45
Mechanical characteristics
Durability (number of operating cycles)
Weight of 3 P switch (kg) 20.5 21.0 21.6 25.7 25.7 42.0 42.0 52.3
Weight of 4 P switch (kg) 24.8 25.6 26.2 32.0 32.0 52.9 52.9 66.6
(1) Category with index A = frequent operation - Category with index B = infrequent operation. (4) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For
(2) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-".4-pole device with 2 pole coordination with specific circuit-breaker references, higher short-circuit current values are
in series by polarity. available. Please consult us.
(3) The power value is given for information only, the current values vary from one manufacturer (5) Data at 415 VAC.
to another.
SIRCOVER I-I+II -II and SIRCOVER Bypass - Characteristics according to IEC 60947-3
125 to 400 A
)XVHSURWHFWHGVKRUWFLUFXLWZLWKVWDQGDVSHU,(&DW9$&
Prospective short-circuit current (kA rms) 100 100 50 50 18
Associated fuse rating (A) 125 160 200 250 400
&LUFXLWEUHDNHUSURWHFWHGVKRUWFLUFXLWZLWKVWDQGZLWKDQ\FLUFXLWEUHDNHUWKDWHQVXUHVWULSSLQJLQOHVVWKDQV
Rated short-time withstand current 0.3s Icw (kA rms) 15 15 15 17 17
Connection
Minimum Cu cable cross-section (mm2) 35 50 50 95 185
Minimum Cu busbar cross-section (mm2)
Maximum Cu cable cross-section (mm2) 50 95 95 150
Maximum Cu busbar width (mm) 25 25 25 32 32
Tightening torque min (Nm) 9 9 9 20 20
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 10 000 10 000 10 000
Weight of 3 P switch (kg) 2.9 2.9 2.9 3.8 3.9
Weight of 4 P switch (kg) 4.1 4.1 4.1 4.6 4.9
(1) Category with index A = frequent operation - Category with index B = infrequent operation. (5) The power value is given for information only, the current values vary from one manufacturer
(2) With terminal shrouds or phase barrier. to another.
(3) 4-pole device with 2 poles in series per polarity. (6) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s.
(4) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-". For coordination with specific circuit-breaker references, higher short-circuit current values
are available. Please consult us.
500 to 1800 A
Thermal current Ith at 40C 500 A 630 A 800 A 1250 A 1600 A 1800 A
Rated insulation voltage Ui (V) 800 1000 1000 1000 1000 1000
Rated impulse withstand voltage Uimp (kV) 8 12 12 12 12 12
)XVHSURWHFWHGVKRUWFLUFXLWZLWKVWDQGDVSHU,(&DW9$&
Prospective short-circuit current (kA rms) 100 70 50 100 100 100
Associated fuse rating (A) 500 630 800 1250 2 x 800 2 x 800
&LUFXLWEUHDNHUSURWHFWHGVKRUWFLUFXLWZLWKVWDQGZLWKDQ\FLUFXLWEUHDNHUWKDWHQVXUHVWULSSLQJLQOHVVWKDQV
Rated short-time withstand current 0.3s Icw (kA rms) 25 25 50 65 100 100
Connection
Minimum Cu cable cross-section (mm2) 240 2 x 150 2 x 185
Minimum Cu busbar cross-section (mm2) 2 x 30 x 5 2 x 40 x 5 2 x 60 x 5 2 x 80 x 5 2 x 80 x 5
Maximum Cu cable cross-section (mm2) 240 240 2 x 300 2 x 300 4 x 185 6 x 185
Maximum Cu busbar width (mm) 40 50 63 63 100 100
Tightening torque min (Nm) 20 20 20 20 40 40
Mechanical characteristics
Durability (number of operating cycles) 5 000 5 000 3 000 3 000 3 000 3 000
Weight of 3 P switch (kg) 9.1 9.1 20.5 21.6 25.7 25.7
Weight of 4 P switch (kg) 11.1 11.1 24.8 26.2 32 32
(1) Category with index A = frequent operation - Category with index B = infrequent operation. (6) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For
(2) With terminal shrouds or phase barrier. coordination with specific circuit-breaker references, higher short-circuit current values are
(3) 4-pole device with 2 poles in series per polarity. available. Please consult us.
(4) 3-pole device with 2 pole in series for the "+" and 1 pole for the "-".
(5) The power value is given for information only, the current values vary from one manufacturer
to another.
Dimensions
SIRCOVER 125 to1800 A
Direct front operation External front operation
A Z1
10 M Z
II
Y Y B
U 8.5 1
W
CA
V
2
A
350
AC
BA
AA
II I
0
125
L1
svr_072_i_1_x_cat
CA
H HA
X T T T H E min.
I
60 45
J C 18
Terminal
Overall dimensions shrouds Switch body Switch mounting Connection
A A J J M M X X
Rating (A) 3p. 4p. C E min AC H HA 3p. 4p. 3p. 4p. N T U V W 3p. 4p. Y Z Z1 AA BA CA
125 221 251 218 208 436 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 135 115 10
160 221 251 218 208 436 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 135 115 10
200 221 251 218 208 436 235 148 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 135 115 10
250 262 312 218 208 436 280 148 25 223 273 196 246 116 50 25 30 11 61 61 3.5 30 124 160 130 15
315 262 312 218 208 436 280 148 25 223 273 196 246 116 50 35 35 11 61 61 3.5 30 124 170 140 15
400 262 312 218 208 436 280 148 25 223 273 196 246 116 50 35 35 11 61 61 3.5 30 124 170 140 15
500 319 379 295 285 513 401 225 25 272 332 246 306 176 65 32 37 13 70.5 65.5 5 43 180 235 205 15
630 319 379 295 285 513 400 225 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 260 220 20
800 386 466 375 425 577 459 298 29 306.5 386.5 255 336 250 80 50 60.5 15 48 48 7 66.5 253.5 321 26.5
1000 386 466 375 425 577 459 298 29 306.5 386.5 255 336 250 80 50 60.5 15 48 48 7 66.5 253.5 321 26.5
1250 386 466 375 425 577 459 298 29 306.5 386.5 255 336 250 80 60 65 16x11 48 48 7 66.5 255.5 330 29.5
1600 478 598 375 425 577 461 298 29 388.5 518.5 347 467 250 120 90 43.5 12.5x5 54 54 8 66.5 255.5 288 15
1800 478 598 375 425 577 461 298 29 388.5 518.5 347 467 250 120 90 43.5 12.5x5 54 54 8 66.5 255.5 288 15
498
461
258
250
380
svr_150_a_1_x_cat
II
Z
U 8.5 Y Y Y
W
CA
V
2
AC
BA
AA
N I II I
0
L1
CA
X T T T
I
H
J C 18
=
250 to 630 A
A B C C. External double lever handle: 800 to
1600 A
330
1. Terminal shrouds
svr_070_i_1_x_cat
61
Terminal
Overall dimensions shrouds Switch body Switch mounting Connection
M
Rating A A E J 3+6 J 4+8 M 3+6 4+8 X X
(A) 3+6p. 4+8p. C min AC H HA p. p. p. p. N T U V W 3+6p. 4+8p. Y Z Z1 Z1 AA BA CA
125 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 219 135 115 10
160 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 219 135 115 10
200 221 251 313 320 235 243 25 182 212 156 186 101 36 20 25 8.5 56 50 3.5 28 124 219 135 115 10
250 262 312 313 298 280 243 25 223 273 196 246 116 50 25 30 11 61 61 3.5 30 124 219 160 130 10
400 262 312 313 298 280 243 25 223 273 196 246 116 50 35 35 11 61 61 3.5 30 124 219 170 140 15
500 319 379 432 417 401 362 25 272 332 246 306 176 65 32 37 13 70.5 65.5 5 43 180 317 235 205 15
630 319 379 432 417 400 362 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 317 260 220 20
800 386 466 560 550 459 479 29 306.5 386.5 255 335 250 80 50 60.5 15 48 48 7 66.5 253.5 439.5 321 26.5
1250 386 466 560 550 459 479 29 306.5 386.5 255 335 250 80 60 65 16x11 48 48 7 66.5 253.5 439.5 320 29.25
1600 478 598 560 550 461 479 29 388.5 518.5 347 467 250 120 90 43.5 12.5x5 54 54 8 66.5 253.5 439.5 288 15
Connection terminals
SIRCOVER and SIRCOVER SIRCOVER and SIRCOVER SIRCOVER 1600 to 3200 A
Bypass 800 A Bypass 1250 A SIRCOVER Bypass 1600 A
9 12.5
16 x 11
5 5
12.5
10 33
15
28.5
15
svr_098_a_1_x_cat
svr_078_b_1_x_cat
svr_077_a_1_x_cat
25 25
15.25
30 30
8.5 33 8.5 45 45
15.75 28.5 15.75
50 90
60
4 5.5
28
90
2 6.5
28
47
.5
37 37
I II 47 47
poign_030_a_1_gb_cat
1414
125
24
22
14 14
14 14
26
45
.5
79
45
45
73
3.
D (1)
5
20 20 20 20
28
78 90 2 6.5
28
.5
90
37 37
350
1414
47 47
I II
poign_031_a_1_gb_cat
24
22
14 14
14 14
26
D (1)
.5
79
45
45
73
3.
5
20 20 20 20
60
25
50
50
poign_023_a_1_gb_cat
90
II
31 4 x 6.5 31 3 x 6.5
71
102
Front operation
Handle type Direction of operation Door drilling
S2 type With lock With lock
0 RONIS EL11AP CASTELL K
90 20 20
90
26 37
78
4 5.5
28
2 6.5
28
47
.5
I II 37 37
47 47
poign_032_a_1_gb_cat
1414
125
24
22
14 14
14 14
26
45
.5
79
45
45
73
3.
D (1)
5
20 20 20 20
Front operation
Handle type Direction of operation Door drilling
S3 type 0 With lock With lock
RONIS EL11AP CASTELL K
90 20 20
90
78 26 37
47 4 5.5
28
2 6.5
28
.5
I II
37 37
1414
poign_033_a_1_gb_cat
47 47
210
24
22
14 14
14 14
26
.5
79
45
45
D (1)
73
3.
5
61 20 20 20 20
Front operation
Handle type Direction of operation Door drilling
C type With lock
CASTELL K
50 50
II 96
28
90
4 6.5
300
0
25
poign_022_a_1_gb_cat
50
50
90
I
31 4 x 6.5 31 3 x 6.5
> Industry.
Changeover
svr_133_a
Strong points
SIRCOVER ATS Bypass
I-0-II 12+4P
> Stable positions.
> Secured breaking.
> On load switching.
Function > A complete solution.
SIRCOVER ATS Bypass switches are manual four pole changeover switches with positive break
indication. They are designed to isolate ATS type electrical equipment (automatic transfer switch)
or UPS, with minimum interruption to the load supply. Integrating a SOCOMEC changeover switch Conformity to standards
into the installation enables source selection when in Bypass (see operating principle below).
> IEC 60947-3
Advantages
Stable positions Secured breaking
SIRCOVER ATS Bypass switches have 3 Simultaneous upstream and downstream
stable positions which are not affected by isolation and fully visualised breaking.
voltage drops or vibrations.
A complete solution
On load switching The SIRCOVER ATS Bypass is a single
3G@MJRSNHSR "BG@Q@BSDQHRSHBRSDRSDC product offering a genuine solution
HM@BBNQC@MBDVHSGRS@MC@QC($" incorporating both an equipment isolation
the SIRCOVER ATS Bypass enables on load function and a switching function.
switching.
Operating principle
T2 T1
In Bypass position:
S2 q Without SIRCOVER: The load is supplied directly
S2
by one of the two power sources (transformer T1 for example).
q With a SIRCOVER: The supply source
SIRCOVER can be selected.
II1 II2
S1
ATS
atys_569_d_1_gb_cat
S2
II3 I
BY-PASS ATS
Load
References
125 A
/ 4100 9813
/
4109 4019
/ /
160 A
/ 4100 9816 200 mm 2694 4014 (2)(3) 1509 4012(4)
1401 1520
S3 type S3 type
Black IP65 Black IP65 320 mm /
250 A
/ 4100 9825
(.(( (.(( 1401 1532 4109 4025
1433 3113 1433 3113
LL
1401 1540 / / /
/ 4100 9840
4109 4039 2694 4021(2)(3) 1509 4025(4)
st
1 contact
NO/NC
/ included / /
630 A
/ 4100 9863
4109 4063 nd
2 contact 2694 4051 (2)(3) 1509 4063(4)
NO/NC
4109 0021(1)
800 A
/ 4100 9880
/
4109 4080
1000 A
/ 4100 9881
Black IP65
Black Included with the Please consult /
(((
2799 7062 external handle us 1509 4080(4)
2799 7147
1250 A
/ 4100 9882
/
4109 4160
1600 A
/ 4100 9886
(1) 2 pieces: one for position I and one for position II.
(2) To fully shroud front, rear, top and bottom 8 references required.
(3) To shroud front switch top and bottom 4 references required.
(4) For complete front protection, order the reference twice.
Accessories
Key handle interlocking system
acces_001_a_1_x_cat
Fig. 3
"G@Q@BSDQHRSHBR@BBNQCHMFSN($"
125 to 1600 A
Thermal current Ith at 40C 125 A 160 A 250 A 400 A 630 A 800 A 1000 A 1250 A 1600 A
Rated insulation voltage Ui (V) 800 800 800 800 1000 1000 1000 1000 1000
Rated impulse withstand voltage Uimp (kV) 8 8 8 8 12 12 12 12 12
Connection terminals
SIRCOVER ATS Bypass 800 to 1000 A SIRCOVER ATS Bypass 1250 to 1600 A
9 12.5
5 5
12.5
10 33
svr_098_a_1_x_cat
15
15
RUQ>>@>>W>B@S
25 25
8.5 33 8.5 30 30
45 45
50
90
Dimensions
SIRCOVER ATS Bypass 125 to 630 A
Direct front operation External front operation
A Z1
M
Z
W 6 8.5
U Y Y
CA
V
II I A
BA
AA
210
210
CA
19
@SXR>>B>>W>B@S
H 25
H E min.
1 61
X T T T T T T X 61
J J1 A. S3 type handle for external front operation: 125 to 630 A.
1. Max length with shaft extension: E min + 50 mm.
Overall Switch
Rating dimensions Switch body mounting Connection
(A) A 8p. E min H J 8p. J1 8p. M 8p. N T U V W X 8p. Y Z Z1 AA BA AC
125 610 2601 193 238 338 101 36 20 25 8.5 3.5 135 115 10
160 610 2601 193 238 338 101 36 20 25 8.5 3.5 135 115 10
250 2601 193 295 396 691 116 50 25 30 11 83.5 3.5 160 130 10
2601 193 295 396 691 116 50 35 35 11 83.5 3.5 15
630 850 358 816 65 50 13 91.5 5 62 199 235 220 20
90
V
250
380
AA
BA
545
@SXR>>A>>W>B@S
CA
X T T T J1 T T T X 19
J J 344
425 E min. = 460 110
Overall Switch
dimensions Switch body mounting Connection
Rating (A) A 8p. J 8p. J1 8p. M 8p. T V X 8p. Y Z AA BA AC
800 1 055 510.5 189 1 021 80 60.5 81.5
321 268 26.5
1000 1 055 510.5 189 1 021 80 60.5 81.5
321 268 26.5
1250 1 320 195 1 286 120 88 8 85.5 288 258 15
1600 1 320 195 1 286 120 88 8 85.5 288 258 15
S3 type 0 V type
90 20 20
90
50
78 II
47
I II 90
ONHFM>>@>>FA>B@S
4 6.5
ONHFM>>@>>FA>B@S
1414
545
0
210
50
90
D (1)
I 31
61
Conformity to standards(1)
> UL98,
switches
Guide WHTY,
svr-ul_014_b_1_cat
file 201138
> UL1008,
Guide WPYV,
file 317092
> CSA 22.2#4,
Class 4651-02
(1) Product reference on request.
svr-ul_013_a_2_cat
Function
SIRCOVER UL UL1008/98 are heavy duty manual transfer switches. They ensure switching
transfer of sources or transfer of two low voltage circuits on load as well as their safety
disconnection.
These switches are extremely durable and are tested and approved for use in the most
demanding applications, such as resitive load or total system applications.
Advantages
Stable positions On load switching
SIRCOVERs have three stable positions The SIRCOVER UL enables secure and reliable
which are not affected by voltage drops or switching, without the need for pre-breaking
vibrations, thus protecting your load against upstream.
network interference.
Compact design
The Sircover are based on a back-to-back
switching technology, providing a compact
solution.
svr_136_a_2_cat
References
UL 1008 and UL98
2P 4150 2011
4P 4150 4021
2P 4150 2041
2P
4159 2041 2P & 3P
3P 4158 3041
400 A 3P 4150 3041
4159 3041 4P
S3 type 4P 4158 4041
Black 4159 4041
4P 4150 4041 I - 0 - II
4, 4X S3, S4 type
143D 3113 200 mm
7.9 inches
3P 4150 3060 3P 3P
1401 1520
Black 4159 3063 1609 3063
600 A
4199 7012 320 mm 4P 4P
4P 4150 4060 12.6 Inches 4159 4063 1609 4063
1401 1532
400 mm
3P 4150 3080 15.7 Inches
1401 1540 Contact NO/NC
800 A
as standard
4P 4150 4080 S4 type
3P 3P
Black
Black 4159 3080 1609 3080
I - 0 - II
4199 7062 4P 4P
4, 4X
3P 4150 3120 4159 4080 1609 4080
144D 3813(1)
1200 A
4P 4150 4120
Accessories
Direct handle
Rating (A) Colour Handle type Reference
100 400 Black 1 lever 4199 4012
600 1200 Black 2 lever 2799 7042
acces_129_a_1_cat
External handle
Handle Lockable in Use
Rating (A) type Colour Nema type 3 positions Reference The handle interlocking function prevents the user from opening
100 ... 200 S2 Black 4, 4X no 142D 2113
the door of the enclosure when the switch is in the "ON" position.
100 ... 200 S2 Red/Yellow 4, 4X no 142E 2113
100 ... 200 S2 Black 1, 3R, 12 no 142F 2113 Opening the door when the switch is in the "ON" position is possible
100 ... 200 S2 Red/Yellow 1, 3R, 12 no 142G 2113 by defeating the interlocking function (Not S5 and V handles) with the
100 ... 200 S2 Black 4, 4X yes 142D 2813 use of a tool (authorized persons only).
100 ... 200 S2 Red/Yellow 4, 4X yes 142E 2813 The interlocking function is restored when the door is re-closed.
100 ... 200 S2 Black 1, 3R, 12 yes 142F 2813
100 ... 200 S2 Red/Yellow 1, 3R, 12 yes 142G 2813
400 ... 600 S3 Black 4, 4X no 143D 3113
400 ... 600 S3 Red/Yellow 4, 4X no 143E 3113
acces_150_a_1_cat
400 ... 600 S3 Black 1, 3R, 12 no 143F 3113
400 ... 600 S3 Red/Yellow 1, 3R, 12 no 143G 3113
400 ... 600 S3 Black 4, 4X yes 143D 3813
400 ... 600 S3 Red/Yellow 4, 4X yes 143E 3813
400 ... 600 S3 Black 1, 3R, 12 yes 143F 3813
400 ... 600 S3 Red/Yellow 1, 3R, 12 yes 143G 3813
800 ... 1200 S4 Black 4, 4X no 144D 3113
800 ... 1200 S4 Black 1, 3R, 12 no 144E 3113
800 ... 1200 S4 Black 1, 3R, 12 no 144E 3113
800 ... 1200 S4 Red/Yellow 1, 3R, 12 no 144G 3113
800 ... 1200 S4 Black 4, 4X yes 144D 3813
800 ... 1200 S4 Red/Yellow 4, 4X yes 144E 3813
800 ... 1200 S4 Black 1, 3R, 12 yes 144F 3813
acces_151_a_1_cat
acces_152_a_1_cat
acces_286_a_2_cat
800 ... 1200 S4 Red/Yellow 1, 3R, 12 yes 144G 3813
800 ... 1200 S5 Black 1, 3R, 12(1) no 1453 8113
800 ... 1200 S5 Red/Yellow 1, 3R, 12(1) no 1454 8113
800 ... 1200 V1 Black 1, 3R, 12(1) no 4199 7149
(1) For 4, 4X please consult us.
100 ... 200 S2 type 15.7 400 10 22.1 254 562 1400 1040
400 S3 type 7.9 200 12 18.4 305 467 1401 1520
400 S3 type 12.6 320 12 23.1 305 587 1401 1532
400 S3 type 15.7 400 12 26.3 305 667 1401 1540
600 S3 type 7.9 200 20 23.4 508 594 1401 1520
600 S3 type 12.6 320 20 28.1 508 714 1401 1532
600 S3 type 15.7 400 20 31.3 508 794 1401 1540
acces_202_a_1_x_cat
800 ... 1200 S4 type 7.9 200 20 23.4 508 594 1401 1520
800 ... 1200 S4 type 12.6 320 20 28.1 508 714 1401 1532
800 ... 1200 S4 type 15.7 400 20 31.3 508 794 1401 1540
800 ... 1200 V1 / S5 type 12.6 320 20 28.1 508 714 4199 3018
800 ... 1200 V1 / S5 type 15.7 400 20 31.3 508 794 4199 3019 X
Bridging bars
Use
Creation of a common point, above or below the switch, between positions I and II.
Rating (A) No. bridging bar Reference
100 200 2 4159 2021
acces_205_a_1_cat
100 200 3 4159 3021
100 200 4 4159 4021
400 2 4159 2041
400 3 4159 3041
400 4 4159 4041
600 3 4159 3063
600 4 4159 4063
800 1200 3 4159 3080
800 1200 4 4159 4080
acces_207_a_1_cat
400 4P 4158 4041
600 6P 1609 3063
600 4P 1609 4063
800 1200 3P 1609 3080
800 1200 4P 1609 4080
Auxiliary contacts
Use Electrical characteristics
Pre-break and signalisation of positions . A300.
For low level ACs and other ACs contact us.
acces_065_a_1_cat
NO/NC auxiliary contact
Rating (A) Contact (s) Reference
100 ... 400 NO/NC on position 1 and 2 4159 0021
Low level NO/NC
100 ... 400 4159 0022
on position 1 and 2
600 ... 1200 NO/NC on position 1 and 2 as standard
Terminal lugs
Use
Connection of bare copper cables onto the terminals (without lugs).
No wires Lugs
Rating (A) Wires range per lug per kit Wires Reference
100 ... 200 6 - 300MCM 1 2 Cu / Al 3954 2020
100 ... 200 6 - 300MCM 1 3 Cu / Al 3954 3020
100 ... 200 6 - 300MCM 1 4 Cu / Al 3954 4020
400 4 - 600MCM 1 2 Cu / Al 3954 2040
400 4 - 600MCM 1 3 Cu / Al 3954 3040
ul_032_a
Characteristics
Characteristics according to UL1008
100 to 1200 A
General use rating (A) 100 A 200 A 400 A 600 A 800 A 1200 A
Operation voltage 600 600 600 600 600 600
Short circuit rating at 600 VAC (kA) 100 100 65 100 100 100
Type of fuse J J J L L L
Max. fuse rating (A) 200 400 600 800 1000 1600
Short circuit rating with circuit breaker (kA/ms) 10 / 25 10 / 25 14 / 50 35 / 50 35 / 50 35 / 50
Mechanical endurance
Endurance (number of operating cycles) 6050 6050 6050 6050 3550 3550
Connection terminals
Min. connection section / AWG #6 #6 #4 / 2 x #6 2x #2 4x #2 4x #2
600MCM /
Max. connection section / AWG 300MCM 300MCM 2x 600MCM 4x 600MCM 4x 600MCM
2x 350MCM
Mechanical characteristics
Endurance (number of operating cycles) 10000 8000 6000 6000 3500 3500
Operating torque (lbs.in/Nm) 88.5/10 88.5/10 128.3/14.5 327.5/37 442.5/50 442.5/50
Auxiliary contacts
Electrical characteristics A300 A300 A300 A300 A300 A300
(1) With 2 poles in series (2) With 3 poles in series (3) General use rating at 600 VDC with 3 poles in series
Mounting orientation
SIRCOVER - 100 to 400 A SIRCOVER - 600 to 1200 A
sirco-ul_029_a_1_x_cat
sirco-ul_030_a_1_x_cat
Dimensions (in/mm)
100 to 200 A
6.37
162
5.21
0.53
13.3
132.5 0.98
1.51 6.30 (3P) - 8.26 (4P) 1.37
25
38.5 160 (3P) - 210 (4P) 35
1.18
30
0.43
11
132.5
5.21
2.67
68
0.35
5.31
1.35
6.30
0.29
160
7.5 9
0.27
7
132.5
5.21
132.5
5.21
svr-ul_015_a_x_cat
6.93 1.97
176 50
9.60 (3P) - 11.57 (4P)
244 (3P) - 294 (4P)
400 A
9.41
239
1.38
0.49
20
7.48
45
190
2.04 8.26 (3P) - 10.63 (4P) 1.37
52 210 (3P) - 270 (4P) 35
1.96
50
0.5
13
203
8
2.70
68.5
10.23
7.67
0.29
195
260
7.5
0.35
9
0.27
7
6.53
166
203
8
svr-ul_016_a_x_cat
6.51 2.56
165.5 65
11.85 (3P) - 14.21 (4P)
301 (3P) - 361 (4P)
600 A
0.41
10.5
14.56
370 Fix 10.04 (3P) - 13.18 (4P)
9.98 2.02
253.5 Fix 255 (3P) - 335 (4P) 51.5
0.82 1.12
28.5
2.61
66.5
21
9.09
231
0.98
25
4.92
125
1.96
50
13.38
9.84
250
340
9.05
9.09
svr-ul_003_a_x_cat
230
231
13.66 3.15
347 80
15.19 (3P) - 18.34 (4P)
386 (3P) - 466 (4P)
13.5
1.49
38
343
0.82
21
11.65 Fix 13.66 (3P) - 18.38 (4P) 2.02
296 Fix 347 (3P) - 467 (4P) 51.5
4.24 1.02 1.49 1.02 4.72
107 26 38 26 120
3.54
90
11.85
301
4.92
125
11.34
9.84
250
288
svr-ul_004_b_x_cat
11.85
301
2
1
1.3
1.49
35
4.7
38
51 0.53
13.46
0.45 2.8 0.63
49.30
1.94
sirco-ul_026_b_1_cat
1.19
sirco_115_b_1_x_cat
sirco_116_b_1_x_cat
30.23
31.75
1.25
1.12
28.6
0.25
11.13
0.44
6.35
1.8
46
2.87
73
2 x 600 kcmil
External handles dimensions (in/mm)
SIRCOVER 100 and 200 A
Front operation
Handle type Direction of operation Door drilling
S2 type
I
3.07 90
0.79
D (1)
78
20
0
4.92
125
svr-ul_010_a_1_gb_cat
20
0.79
1.77 14 14 47
45
II
0.79
78
20
0
svr-ul_012_a_1_gb_cat
0.79
20
8.27
9
210
0
0.55 0.55
II 14 14
2.36
61
0.55
78
14
13.77
350
svr-ul_011_a_1_gb_cat
14
0.55
90
D (1)
I
2.36
60
S5 type
with V Escutcheon
II 50
90
4 6,5
498
0
50
90
poign_023_a_1_gb_cat
I
31
71
102
Front operation
Handle type Direction of operation Door drilling
V1 type 50
1.97
II
90
4 0.25
4 6.5
21.46
545
sirco-ul_031_a_1_gb_cat
1.97
0
50
90
1.22
4.80 I 31
122
for PV applications.
svr-pv_003_a_1_cat
Strong points
Function
Conformity to standards
SIRCOVER PV switches are manual multipolar changeover switches with positive break
indication. They ensure source inversion or changeover under load of two photovoltaic > IEC 60947-3
installation circuits.
Advantages
Stable positions Patented safety disconnection A compact solution.
SIRCOVER PV switches have three stable A glass fibre reinforced polyester break
positions which are not affected by voltage chamber with an arc extinguishing system > The products are available in
drops or vibrations. provides a patented safety disconnection enclosures.
system offering rapid extinguishing of the
Secured breaking electric arc up to 1000 VDC and current
interruption up to 630 A.
Simultaneous upstream and downstream
isolation and positive break indication.
Application
The choice of the material cannot be separated from the concept of energy management.
Many applications may require continuous power supply during a PV generator fault, when an isolated site has been electrified, in developing
countries, in telecommunications or pumping. SIRCOVER PV changeover switches ensure source inversion or switching under load between two
circuits.
Source transfer: manual changeover Equipment earthing as for a string of Load inverter : switching the power supply
between two photovoltaic sources or a photovoltaic panels. from one load to another in order to guarantee
photovoltaic source and a generator set. continuous power supply during maintenance
operations.
comut_035_a_1_x_cat
comut_036_a_1_x_cat
comut_037_a_1_x_cat
Functional diagram
2
svr_103_c_1_x_cat
References
SIRCOVER PV I-0-II
Accessories
Direct operation handle
Rating (A) Handle colour Handle type Reference
200 630 Black Single lever 4199 5012
acces_114_a_1_cat
External operation handle
Use
Door interlocked external front operation handles include an escutcheon,
are padlockable and must be utilised with an extension shaft.
acces_150_a_1_cat
S3 type handle
acces_187_a_1_cat
To be ordered
Handle colour External IP(1) in multiples of Reference
Black IP65 1 1493 0000
(1) IP: protection degree according to IEC 60529 standard.
acces_198_a_2_cat
To be ordered
Colour in multiples of Handle Reference
Light grey 50 S2, S3 type 1401 0001
Dark grey 50 S2, S3 type 1401 0011
acces_260_a_2_cat
misalignment of up to 15 mm.
Required for a shaft length over 320 mm.
Description Reference
Shaft guide 1429 0000
acces_369_a_1_cat
Standard lengths: Other lengths: Please consult us.
- 200 mm,
- 320 mm.
Dimension X
Rating (A) Length (mm) (mm) Type Reference
200 250 200 210 310 10 x 10 1400 1020
Type 10x10
acces_144_b_1_cat
Type 10x10
acces_202_a_1_cat
Accessories (continued)
Bridging bars
Use
For creating a common connection between switches I & II, on the
top or bottom side of the SIRCOVER, to enable, for example, the
load to be fed from either incoming source (I or II).
acces_205_a_2_cat
svr_124_a_1_cat
Rating (A) No. of poles Section (mm) Mounting Reference
200 250 1P 25 x 2.5 client 4109 0025
200 250 2P 25 x 2.5 client 4109 2025
400 630 1P 50 x 5 client 4109 0063
400 630 2P 50 x 5 client 4109 2063
Auxiliary contact
Use Connection to the control circuit
Pre breaking and signalling of positions 6.35 mm fast-on terminal.
I and II: 1 or 2 NO/NC auxiliary contacts Electrical characteristics
in each position. Low level auxiliary 30 000 operations.
acces_065_a_1_cat
contacts: please consult us.
Characteristics
Operating current Ie (A)
Nominal 250 VAC 400 VAC 24 VDC 48 VDC
Rating (A) current (A) AC-13 AC-13 AC-13 AC-13
200 630 16 12 8 14 6
svr_058_a_1_cat
References
NO/NC changeover contact
Rating (A) Contact(s) Reference
200 630 1st/2nd 4109 0021
Terminal shrouds
Use Advantage
Protection against direct contact with Perforations allow remote thermographic
acces_206_a_2_cat
Terminal screens
Use
Top and bottom protection against direct contact with terminals or
connection parts.
Rating (A) No. of poles Position Pack Reference
200 250 3P top / bottom 1 1509 3025
acces_207_a_2_cat
200 250 4P top / bottom 1 1509 4025
400 630 3P top / bottom 2 1509 3063
400 630 4P top / bottom 2 1509 4063
acces_061_a_2_x_cat
determined as standard or configured by
the user by removing the pre-formed tabs.
Padlocking and locking can be combined.
Padlocking in position I, 0 or II
Rating (A) Operation Figure Reference
200 250 external 1 1423 2813
Fig. 1
acces_001_a_1_x_cat
Locking using RONIS EL11AP lock in position 0 (not supplied)
Rating (A) Operation Figure Reference
200 630 direct 2 4109 1006(1)
200 630 external 3 1499 7701
(1) Specific handle included.
Fig. 3
Connection
Rigid Cu cable cross-section (mm2) 95 120 240 2 x 150 2 x 185
Maximum Cu busbar width (mm) 32 32 32 40 40
Tightening torque min (Nm) 20 20 20 40 40
Mechanical characteristics
Durability (number of operating cycles)(1) 10 000 10 000 5 000 5 000 5 000
Weight of a 3 pole device (kg) 3,8 3,8 9 9 9
Weight of a 4 pole device (kg) 4,6 4,6 11 11 11
(1) Improved endurances: Please consult us.
Dimensions
SIRCOVER 200 to 630 A
Direct front operation External front operation
A Z1
10 M Z
Y Y
II
U 8.5 1
W
CA
A B
2
AC
BA
AA
II I
0
svr_072_i_1_x_cat
125
L1
210
CA
H HA
X T T T H E min.
I
J C 18 45 61
Terminal
Overall dimensions shrouds Switch body Switch mounting Connection
Rating X X
(A) A 3p. A 4p. C E min AC H HA J 3p. J 4p. M 3p. M 4p. N T U V W 3p. 4p. Y Z Z1 AA BA CA
200 262 312 218 208 436 280 148 25 223 273 196 246 116 50 25 30 11 61 61 3,5 30 124 160 130 15
250 262 312 218 208 436 280 148 25 223 273 196 246 116 50 25 30 11 61 61 3,5 30 124 160 130 15
400 319 379 295 285 514 400 225 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 260 220 20
500 319 379 295 285 514 400 225 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 260 220 20
630 319 379 295 285 514 400 225 25 272 332 246 306 176 65 45 50 13 70.5 65.5 5 43 180 260 220 20
26 37
78
4 5.5
28
2 6.5
28
47
.5
I II 37 37
47 47
1414
125
24
poign_032_a_1_gb_cat
22
14 14
14 14
26
45
.5
79
45
45
73
3.
D (1)
5
20 20 20 20
Front operation
Handle type Direction of operation Door drilling
S3 type 0 With lock With lock
RONIS EL11AP CASTELL K
90 20 20
90
78 26 37
47 4 5.5
28
2 6.5
28
.5
I II
37 37
1414
47 47
210
24
poign_033_a_1_gb_cat
22
14 14
14 14
26
.5
79
45
45
D (1)
73
3.
5
61 20 20 20 20
-
sirco_305_b_1_gb_cat
sirco_307_b_1_gb_cat
+
+ -
Load Load
ATyS M 3s
I-0-II 4P
Strong points
ATySm_007_a_1_cat
ATySm_214_a_1_cat
Advantages
Proven technology Choice of configuration interface
(1) Product reference on request.
Two mechanically interlocked SIRCO MV ATyS M 6 automatic changeover switches
load break switches provide rapid switching, are available with a simple or an advanced
excellent dynamic withstand and a high integrated configuration and control interface:
number of operations. q ATyS M 6s are configured through
the adjustment of dip switches and
Stable positions potentiometers.
The ATyS M has three stable positions q ATyS M 6e are configured through the use
which are not affected by voltage drops or of pushbuttons and a display.
vibrations, thus protecting your load against
network interference. Return to position 0
Depending on its configuration, the
Secure operation 3X2,DDM@AKDR@QDSTQMSNONRHSHNM
ATyS M provide positive break indication, if the power is cut.
confirming switch position, and a back-up
manual operation function.
Modes of operation
ATySm_015_b_1_cat
ATySm_016_b_1_cat
ATySm_014_b
ATySm_029_b
ATySm_042_a_1_gb_cat
order II
position I
position O
position II
no Manual
Switch to position 0 operation
Semi automatic mode
yes
End t stop to position 0 Example (generator application):
End t source 1 availability
Source 1 : priority power source
Switch to position II Source 1 availability Source 2 : backup power source
Configuration t : timer
ATyS M 6s ATyS M 6e
q Common points between the three-phase and single-phase versions: q Applications: Transformer/Genset, Transformer/Transformer,
- 2 potentiometers (normal supply loss and return time delays) with or without priority.
- 2 dip-switches (Pause for 2 seconds in position 0 during switching I<->II ; q Display + keyboard (Device configuration; Displays supply measurements;
Transformer/Transformer or Transformer/Genset application). Test and control mode access).
q 4 LEDs (Source availability indicators; "AUT" Automatic mode; Fault). q LEDs (Product Power On ; Source availability indicators; Position indication;
q 3 inputs for external control (Inhibition of the automatic mode; Remote test on "AUT" Automatic mode; TEST/CONTROL Mode ; Fault).
load (Priority selection for Transformer/Transformer); Manual retransfer from q 3 configurable inputs.
the alternate supply to the normal supply). q 3 configurable output relays.
q 1 NO bi-stable output relay for generator starting/stopping. q 1 configurable output relay for generator starting/stopping.
q 1 NC relay for product availability. q Connection of a remote interface ATyS D10 or D20.
q Specific to three-phase ATyS M: q RS485 MODBUS communication (COM version).
-2 additional potentiometers (Nominal voltage; Voltage/frequency thresholds)
- 2 additional dip switches (50 or 60 Hz; network selection)
q Specific to the single-phase ATyS M:
/1&ATSSNMUNKS@FD@MCMNLHM@KEQDPTDMBX@TSNBNMEHFTQ@SHNM
References
ATyS M 3s
Voltage sensing
Power supply and power supply Auxiliary contact
Rating (A) No. of poles voltage ATyS M 3s Bridging bars tap Terminal shrouds block
2P 230 VAC 1323 2004
40 A
4P 230 VAC 1323 4004 1st A/C block
2P 230 VAC 1323 2006 included
63 A
4P 230 VAC 1323 4006 2P
2P 230 VAC 1323 2008 1309 2006 2nd A/C block
80 A Separate common
4P 230 VAC 1323 4008 4P 2 pieces 2 pieces
1309 4006 points
2P 230 VAC 1323 2010 1399 4006 2294 4016(1)
100 A 1309 0001(2)
4P 230 VAC 1323 4010
2P 230 VAC 1323 2012 Linked common
125 A
4P 230 VAC 1323 4012 points
2P 230 VAC 1323 2016 1309 2016 1309 0011(2)
160 A
4P 230 VAC 1323 4016 1309 4016
(1) For the three-phase version (4 P), for upstream and downstream protection, please order the reference twice. For the single-phase version (2 P) please order the reference once.
(2) 1 NO/NC contact block for positions I, 0 and II.
ATyS M 6s
Voltage sensing
and power Terminal Auxiliary contact
Rating (A) No. of poles Network (VAC) ATyS M 6s Bridging bars supply tap shrouds block Sealable cover
2P 230 1353 2004
40 A 4P 127/230 1353 4004
4P 230/400 1354 4004
2P 230 1353 2006
63 A 4P 127 / 230 1353 4006
4P 230 / 400 1354 4006
2P 230 1353 2008 2P 1 piece
1309 2006
80 A 4P 127 / 230 1353 4008
4P Separate common
4P 230 / 400 1354 4008 1309 4006 2P
points
2P 230 1353 2010 2 pieces 2 pieces 1359 2000
1309 0001(2)
100 A 4P 127 / 230 1353 4010 1399 4006 2294 4016(1) 4P
1359 0000
4P 230 / 400 1354 4010 Linked common
2P 230 1353 2012 points
125 A 4P 127 / 230 1353 4012 1309 0011(2)
4P 230 / 400 1354 4012
2P
2P 230 1353 2016
1309 2016
160 A 4P 127 / 230 1353 4016
4P
4P 230 / 400 1354 4016 1309 4016
(1) For the three-phase version (4 P), for upstream and downstream protection, please order the reference twice. For the single-phase version (2 P) please order the reference once.
(2) 1 NO/NC contact block for positions I, 0 and II.
ATyS M 6e
Voltage sensing
Rating ATyS M 6e + and power Terminal Auxiliary Remote control
(A) No. of poles Network (VAC) ATyS M 6e COM Bridging bars supply tap shrouds contact block interface
4P 127 / 230 1363 4004 1383 4004
40 A
4P 230 / 400 1364 4004 1384 4004
4P 127 / 230 1363 4006 1383 4006
63 A 1 piece
4P 230 / 400 1364 4006 1384 4006
4P 127 / 230 1363 4008 1383 4008 4P Separate
80 A ATyS D10
4P 230 / 400 1364 4008 1384 4008 1309 4006 common points
2 pieces 2 pieces 1599 2010
(1) 1309 0001(2)
4P 127 / 230 1363 4010 1383 4010 1399 4006 2294 4016 ATyS D20
100 A 1599 2020
4P 230 / 400 1364 4010 1384 4010 Linked common
points
4P 127 / 230 1363 4012 1383 4012 1309 0011(2)
125 A
4P 230 / 400 1364 4012 1384 4012
4P 127 / 230 1363 4016 1383 4016 4P
160 A
4P 230 / 400 1364 4016 1384 4016 1309 4016
(1) For upstream and downstream protection please order the reference twice.
(2) 1 NO/NC contact block for positions I, 0 and II.
Accessories
Bridging bars
Use
For providing a common connection between switches I & II on the incoming or outgoing
side of the ATyS M (outgoing side only for ATyS M 6), to enable, for example, the load to be
supplied from either incoming source (I or II).
The bridging bar set does not reduce the connection capacity of the ATyS Ms cage terminals.
atysm_025_a
Rating (A) No. of poles Reference
40 125 2P 1309 2006
160 2P 1309 2016
40 125 4P 1309 4006
160 4P 1309 4016
atysm_026_a
SGDBNMMDBSHNMNEW
LLUNKS@FD connection capacity.
RDMRHMFNQONVDQB@AKDRSN@MX 3X2,
Rating (A) Pack Reference
40 160 2 pieces 1399 4006
Terminal shrouds
Use Required quantity
Protection against direct contact with For upstream and downstream protection
terminals or connecting parts. with a three-phase ATyS M two sets are
Advantages of the terminal shrouds required. For the single-phase version only
Perforations allow remote thermographic one set is required.
atysm_027_a
inspection without the need to remove the
shrouds. Tamper seals can be fitted for
increased security.
Auxiliary contact
Use
Auxiliary contacts for position indication. A reduced (4 cables instead of 6). The ATyS M
maximum of two auxiliary contact blocks 3s is supplied as standard with one auxiliary
can be fitted to each product. Each auxiliary contact block fitted; this A/C block has
access_353_a
Accessories (continued)
Sealable cover
Use
atysm_043_a_2_cat
It prevents access to the configuration panel of the ATyS M 6s.
Polycarbonate enclosure
Use
Dedicated to the implementation of a three-phase ATyS M, it
enables easy access to a compact changeover solution.
atysm_001_a
Rating (A) H x W x D (mm) Reference
40 160 385 x 385 x 193 1309 9006
atysm_039_a_1_x_cat
@CCHSHNM@KRO@BDSNSGDDMBKNRTQDHMNQCDQSNBNMMDBSLLB@AKDRSN
the ATyS M.
Rating (A) Reference
40 160 1309 9007
Residential enclosure
Use
Dedicated to the implementation of a single-phase ATyS M, it
provides a compact IP41 changeover solution with easy access.
atysm_196_a_1_cat
Rating (A) H x W x D (mm) Reference
40 160 410 x 305 x 150 1309 9056
Auto-transformer
Use
For use with ATyS M 6 in 400 VAC three-phase applications without a distributed neutral. As the
ATyS M 6 has integrated measurement and power supply circuits, a neutral connection is required
trafo_165_a_1
for 400 VAC three-phase applications. When no neutral connection is available this autotransformer
(400/230 VAC, 400 VA) provides the 230 VAC required for the ATyS M 6 to function.
Rating (A) Reference
40 160 1599 4121
atys_564_c_1_cat
ATyS M 6e, via the RJ45 connection front of a panel.
atys_565_c_1_cat
cable. Protection degree: IP21
Maximum connection distance: 3 m. Door mounting
ATyS D10 2 holes 22.5.
To display source availability and ATyS M connection via RJ45 cable, 96 x 96 22.5
position indication on the front panel not isolated.
of an enclosure. Cable available as an accessory.
36
Protection degree: IP21
atys_161_a_1_x_cat
atys_597_a_1_cat
40
Description of accessories Reference
20
ATyS D10 1599 2010
ATyS D20 1599 2020
= =
Interfaces are powered from the ATyS M Drillings
acces_209_a_2_cat
To connect between a remote interface RJ45 8 wire straight-through, non isolated
(type D10 or D20) and an ATyS M 6e. cable. Length 3m.
acces_319_a_1_cat
Each power connection terminal is provided with separation screens.
Rating (A) Reference
40 160 1399 4017(1)
For complete conversion, order 3 times the reference.
Dimensions
ATyS M 40 to 160 A
Single-phase ATyS M Three-phase ATyS M
235 340
52 116 52 104 176
116 116
13 26 13 26
atysm_204_a_1_x_cat
131.5
131.5
245
350
143
45
245
1
350
143
45
1
atysm_034_a_1_x_cat
18 18
6 x M6
222 324
46 46
53 53
73.5 73.5
1. Auxiliary contact blocks (2 max). 1. Auxiliary contact blocks (2 max).
atysm_008_b_1_x_cat
atysm_207_a_1_x_cat
1 : position I control
A A
2 : position II control
atysm_040_e_1_x_cat
3 : position 0 control
atysm_205_a_1_x_cat
1 preferred source
A
A 2 alternate source
atysm_206_a_1_x_cat
atysm_212_a_1_x_cat
Three-phase ATyS M 6e
8
9
A
RJ RS 1 preferred source
atysm_211_a_1_x_cat
2 alternate source
1 - 2 - 3 : programmable inputs
4 - 5 - 6 : programmable outputs
B 7 : genset start / stop control
8 : RJ 45 for connecting a ATyS D10/D20 remote interface
9 : RS485 for communication on versions with COM.
4 5 6 7
A: bridging bar (accessories)
B: auxiliary contact block - 1 NO/NC contact per position I , 0, II (accessories)
207 208 209 210 43 44 53 54 63 64 73 74
1 3
2
1 2
Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s
Rated short-time withstand current 0.3s Icw (kA rms) 7 7 7 7 7 7
Connection
Minimum connection cross-section 10 10 10 10 10 10
Maximum Cu cable cross-section (mm2) 70 70 70 70 70 70
Tightening torque (Nm) 5 5 5 5 5 5
Power supply
Power supply voltage 230 VAC min / max (VAC) (ATyS M 3s and ATyS M 6s) 176/288 176/288 176/288 176/288 176/288 176/288
Power supply voltage 230 VAC min / max (VAC) (ATyS M 6e) 160/305 160/305 160/305 160/305 160/305 160/305
Mechanical characteristics
Durability (number of operating cycles) 10 000 10 000 10 000 10 000 10 000 10 000
Weight of single-phase versions - without packaging (kg) 2.8 2.8 2.8 2.8 2.8 2.8
Weight of single-phase versions - with packaging (kg) 3.5 3.5 3.5 3.5 3.5 3.5
Weight of three-phase versions - without packaging (kg) 3.5 3.5 3.5 3.5 3.5 3.5
Weight of three-phase versions - with packaging (kg) 4.2 4.2 4.2 4.2 4.2 4.2
(1) Category with index A = frequent operation - Category with index B = infrequent operation. (4) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For
(2) For a rated operational voltage Ue = 400 VAC. coordination with specific circuit-breaker references, higher short-circuit current values are
(3) Between the command given and reaching of position at Un (under nominal conditions). available. Please consult us.
(5) Only on ATyS M 3s.
> Heating.
switches
atys-s_018_a
Strong points
Easy integration
ATyS S products can be easily installed inside
enclosures.
Their design, and in particular their compact
size, enables integration within most 200 mm
deep enclosures.
References
Terminal
Rating (A) No. of poles Power supply ATyS S Bridging bars Voltage tap Terminal retainer DIN rail
shrouds
4P 24/48 VDC 9506 4004
4P 12 VDC 9505 4004
40 A
4P 2 x 230 VAC 9513 4004
9599 4001
4P 230 VAC 9503 4004
4P 24/48 VDC 9506 4006
4P 12 VDC 9505 4006
63 A
4P 2 x 230 VAC 9513 4006
9599 4001
4P 230 VAC 9503 4006
Source side
4P 24/48 VDC 9506 4008 2 pieces
4P 12 VDC 9505 4008 9594 4012
4P 2 pieces 4 modules
80 A
4P 2 x 230 VAC 9513 4008 9509 4012 9599 4003 9599 4002
Load side
2 pieces
9599 4001
4P 230 VAC 9503 4008
9594 9012
4P 24/48 VDC 9506 4010
4P 12 VDC 9505 4010
100 A
4P 2 x 230 VAC 9513 4010
9599 4001
4P 230 VAC 9503 4010
4P 24/48 VDC 9506 4012
4P 12 VDC 9505 4012
125 A
4P 2 x 230 VAC 9513 4012
9599 4001
4P 230 VAC 9503 4012
Accessories
Bridging bars
Use
For bridging power terminals on the top or bottom side of the switch
atys-s_019_a
Rating (A) No. of poles Reference
40 125 4P 9509 4012
Voltage tap
Use
Enables the required power supply for ATyS S 230 VAC and ATyS Sd
products to be tapped directly from the product's incoming power
atys-s_022_a
terminals. Can also be utilised in applications without neutral, to
provide 400 VAC to the autotransformer.
Terminal retainer
Use
These clips have a dual function:
- To prevent direct access to the power supply and control terminals and
atys-s_021_a
- To secure these connector terminals.
Terminal shrouds
Use
IP2X protection against direct contact with terminals or
connecting parts.
atys-s_020_a
atys-s_020_a
Terminal shrouds for the load side
Rating (A) Pack Reference
40 125 2 pieces 9594 9012
DIN rail
Use
This 4-module DIN rail can be installed directly on the front of Rating (A) Reference
the ATyS S and can be utilised, for example, for the installation 40 125 9599 4002
of a surge protection device.
Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s(1)
Rated short-time withstand current 0.3s. Icw (kA rms) 3.5 3.5 3.5 3.5 3.5
Connection
Maximum Cu cable cross-section (mm2) 50 50 50 50 50
Tightening torque mini / maxi (Nm) 1.2/3 1.2/3 1.2/3 1.2/3 1.2/3
Power supply
Power supply 12 VDC min / max (VDC) 9/15 9/15 9/15 9/15 9/15
Power supply 24/48 VDC min / max (VDC) 17/62 17/62 17/62 17/62 17/62
Power supply 230 VAC min / max (VAC) 160/310 160/310 160/310 160/310 160/310
Mechanical characteristics
Durability (number of operating cycles) 10 000
Weight ATyS S and ATyS Sd 4 P (kg) 3 3 3 3 3
(1) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s. For coordination with specific circuit-breaker references, higher short-circuit current values are available.
Please consult us.
1 preferred source
2 alternate source
1 2 1 : position 0 control
2 : position I control
3 : position II control
4 : auxiliary contact, closed when the switch is in
position 0
5 : auxiliary contact, closed when the switch is in
101102
201202
7
8
position II
atys_830_a_1_x_cat
1 preferred source
2 alternate source
1 2
1 : position 0 control
2 : position I control
3 : position II control
4 : auxiliary contact, closed when the switch is in
atys_832_a_1_x_cat
position 0
301302
position II
6 : auxiliary contact, closed when the switch is in
4 5 6
position I
317 316 315 314 04 01 24 21 14 11 7 : power supply kit: 230 VAC (160-310 VAC)
1 2 3
ATyS S DC version
1 preferred source
1 2 2 alternate source
1 : position 0 control
2 : position I control
3 : position II control
4 : auxiliary contact, closed when the switch is in
position 0
atys_831_b_1_x_cat
401402
position II
4 5 6 6 : auxiliary contact, closed when the switch is in
position I
317 316 315 314 04 01 24 21 14 11 7 : power supply 12 VDC (9-15 VDC) or 24 VDC /
48 VDC (17-62 VDC) depending on the version.
1 2 3
Dimensions
104.5 8 15
11 26.5 27.5 26.5
37
72
100 100
143.5
90.6
106
113
94
72
25
115.2 74 44
198 100
181 42.5
14
M6 125
2
3
45
16
6.4
atys-s_024_a_1_x_cat
Connection terminal
14
atys-s_024_a_1_x_cat
M6
16
users, the ATyS range is constantly evolving the needs of your application.
switches
WEB
SERVE
OPTIONR
Automatic controller
Automatic controller Functions for
Remote to manage
Dual power to manage energy management
Transfer transformer /
supply transformer /
Switch transformer
genset applications Communication options
applications
ATYS-S 027 B
ATyS S
*HQHUDWRUJHQHUDWRU
ATyS C40
ATYS-S 028 B
ATyS S
7UDQVIRUPHUWUDQVIRUPHU
ATyS Sd
> OEM.
switches
Strong points
atys_d_001_a_1_cat
Conformity to standards
Function
> IEC 60947-6-1
The ATyS and ATyS d are three-phase motorised changeover switches with positive break > IEC 60947-3
indication. They enable the on load transfer of two three-phase supplies via remote volt-free
contacts, from either an external automatic controller, using pulse logic, or a switch.
They are intended for use in low voltage power systems where interruption of the load supply
is acceptable during transfer.
Enclosed solution
> Please consult us.
Advantages
External automatic controller
Watchdog relay to check product Extended power supply range
availability ATyS and ATyS d products offer greater > The ATyS and ATyS d
ATyS and ATyS d products are equipped with availability thanks to their extensive power are compatible with our
a Watchdog relay which constantly monitors supply range of 208 to 277 VAC 20%. $7\6}&H[WHUQDOFRQWUROOHUV
the product, thereby securing your installation. (for transformer/transformer
This relay informs the user of the product's ATyS d: ATyS with integrated DPS and transformer/generator
availability, i.e. whether it is operational and In addition to the functions offered by the DSSOLFDWLRQVDQG$7\6}&
ready for source switching. ATyS, the ATyS d incorporates supply FRQWUROOHUV}
redundancy without the need for additional (for generator/generator
Integrated auxiliary contacts wiring. This is obtained by integrating a double applications).
As part of the product monitoring function, the RTOOKXHMCDODMCDMSRTOOKHDRCHQDBSKXVHSGHM
ATyS and ATyS d enable the transmission of the product.
information relating to their position.
This is possible thanks to the standard
integration of an auxiliary contact for each
position.
References
applications.
switches
atys_t_001_a_1
Strong points
Conformity to standards
> IEC 60947-6-1
> IEC 60947-3
Advantages
Rapid commissioning Functions adapted to
ATyS t switches offer significant time saving transformer/transformer applications
during commissioning (process takes 2 to ATyS t products are automatic changeover
LHMTSDR
!DB@TRDSGDXG@UDNMKXSVN switches intended specifically for transformer/
potentiometers and four DIP switches, a transformer applications. Their integrated
simple screwdriver is all you need to configure controller has been designed to provide all the
the parameters. functions necessary for these applications,
For added simplicity, they also offer an including monitoring the voltage and
autoconfiguration function which enables frequency of both sources, for three-phase
automatic adjustment of the rated voltage and and single-phase networks.
frequency.
References
3P 9543 3012
125 A
4P 9543 4012
3P 3P
3P 9543 3016 2694 3014(2) 1509 3012
160 A 4109 0019
4P 4P
4P 9543 4016
2694 4014(2) 1509 4012
3P 9543 3020
200 A
4P 9543 4020
3P 9543 3025
250 A 4109 0025
4P 9543 4025
3P 3P 1599 0002(4) 1599 0003(4)
3P 9543 3031 2694 3021(2) 1509 3025
315 A
4P 4P
4P 9543 4031
2694 4021(2) 1509 4025
4109 0039
3P 9543 3040
400 A
4P 9543 4040
3P 9543 3050
500 A 4109 0050
4P 9543 4050 3P 3P
2694 3051(2) 1509 3063(3)
3P 9543 3063 4P 4P
2694 4051(2) 1509 4063(3)
630 A 4109 0063
4P 9543 4063
400/230 VAC
1599 4064
3P 9543 3080
800 A
4P 9543 4080
4109 0080
3P 9543 3100 3P
1000 A 1509 3080(3)
4P 9543 4100 4P
1509 4080(3)
3P 9543 3120
1250 A 4109 0120 1599 0032(4)
4P 9543 4120
3P 9543 3160
1600 A
3P
4P 9543 4160 1509 3160(3)
4109 0160 1599 0004(4)
4P
3P 9543 3180 (3)
1800 A
1509 4160
4P 9543 4180
3P 9543 3200
2000 A
4P 9543 4200
3P 9543 3250
2500 A included included
4P 9543 4250
3P 9543 3320
3200 A
4P 9543 4320
applications.
switches
Strong points
atys_g_001_a_1
Conformity to standards
> IEC 60947-6-1
> IEC 60947-3
Advantages
Rapid commissioning Functions adapted to
ATyS g switches offer significant time saving transformer/generator applications
during commissioning (process takes ATyS g products are automatic changeover
@OOQNWHL@SDKXLHMTSDR
!DB@TRDSGDX switches intended specifically for
have only four potentiometers and four DIP transformer/generator applications. Their
switches, a screwdriver is all that is needed to integrated controller has been designed to
configure the parameters. provide all the functions necessary for these
For added simplicity, they also offer an applications, including monitoring the voltage
autoconfiguration function which enables and frequency of both sources, for three-
automatic adjustment of the rated voltage and phase and single-phase networks.
frequency.
Generator test functions
To ensure compatibility with
transformer/generator applications, ATyS g
switches integrate the following generator test
functions:
Test on load and test off load.
References
3P 9553 3025
250 A 4109 0025
4P 9553 4025
3P 3P 1599 0002(4) 1599 0003(4)
3P 9553 3031 2694 3021(2) 1509 3025
315 A
4P 4P
4P 9553 4031
2694 4021(2) 1509 4025
4109 0039
3P 9553 3040
400 A
4P 9553 4040
3P 9553 3050
500 A 4109 0050
4P 9553 4050 3P 3P
2694 3051(2) 1509 3063(3)
3P 9553 3063 4P 4P
2694 4051(2) 1509 4063(3)
630 A 4109 0063
4P 9553 4063
400/230 VAC
1599 4064
3P 9553 3080
800 A
4P 9553 4080
4109 0080
3P 9553 3100 3P
1000 A 1509 3080(3)
4P 9553 4100 4P
1509 4080(3)
3P 9553 3120
1250 A 4109 0120 1599 0032(4)
4P 9553 4120
3P 9553 3160
1600 A
3P
4P 9553 4160 1509 3160(3)
4109 160 1599 0004(4)
4P
3P 9553 3180
1800 A
1509 4160(3)
4P 9553 4180
3P 9553 3200
2000 A
4P 9553 4200
3P 9553 3250
2500 A included included
4P 9553 4250
3P 9553 3320
3200 A
4P 9553 4320
communication.
atys_003_b_1_cat
Strong points
Conformity to standards
Function > IEC 60947-6-1
ATyS p is a range of three-phase automatic changeover switches with positive break indication. > IEC 60947-3
They incorporate all the functions offered by the ATyS g, as well as functions designed for power
management and enabling communication.
In automatic mode they enable the monitoring of, and the on load changeover switching between,
two power supply sources, in accordance with the parameters configured via pushbuttons and an
LCD screen. Enclosed solution
They are intended for use in low voltage power systems where interruption of the load supply is
acceptable during transfer. > Please consult us.
Advantages Webserver
Front panel
3
1. Slots for optional plug-in modules.
!@BJKHS+"#CHROK@X
1 3. Source availability and position indication LEDs.
4. Pushbuttons for programming and mode selection.
atys-p_001x_a_1
Plug-in modules
q 12KHMJVHSG)!42,.#!42 protocol
RODDCTOSNA@TCR
diris_449_a_1_cat
2 inputs - 2 outputs
ATyS p q Each module has 2 programmable inputs and
2 programmable outputs available.
Ethernet communication
diris_777_a_1_cat
q $SGDQMDSKHMJVHSG,.#!423"/NQ
)!42,.#!42134NUDQ3"/
diris_834_a
MODBUS gateway
q $SGDQMDSKHMJVHSG,.#!423"/NQ
Number of usable modules per product: )!42,.#!42134NUDQ3"/
A maximum of four modules can be fitted to q "NMMDBSHNMNESN12)!42,.#!42RK@UDR
each ATyS p, however with the installation of q Embedded Ethernet Webserver software.
either Ethernet communication module only two
additional modules can be installed.
.MKXNMDOTKRDNTSOTSNMD@M@KNFTDNTSOTS@MC Analogue outputs
diris_448_a_1_cat
Pulse outputs
q 2 configurable pulse outputs (type, weight and
CTQ@SHNMNMJ6GJU@QG@MCJ5 G
References
3P 9573 3025
250 A 4109 0025
4P 9573 4025
3P 3P 1599 0002(4)
3P 9573 3031 2694 3021(2) 1509 3025
315 A
4P 4P
4P 9573 4031
2694 4021(2) 1509 4025
4109 0039
12)!42
3P 9573 3040
400 A ,.#!42
4P 9573 4040 communication
4825 0092
3P 9573 3050
500 A 4109 0050 2 inputs /
4P 9573 4050 3P 3P 2 outputs
2694 3051(2) 1509 3063(3) 4825 0094
3P 9573 3063 4P 4P
2694 4051(2) 1509 4063(3) Ethernet
630 A 4109 0063
communication
4P 9573 4063
4825 0203 400/230 VAC
1599 4064
3P 9573 3080
Ethernet
800 A
communication +
4P 9573 4080
4109 0080 12,.#!42
3P 9573 3100 3P gateway
1000 A 1509 3080(3) 4825 0204
4P 9573 4100 4P
1509 4080(3) Analogue outputs
3P 9573 3120 4825 0093
1250 A 4109 0120 1599 0032(4)
Pulse outputs
4P 9573 4120
4825 0090
3P 9573 3160
1600 A
3P
4P 9573 4160 1509 3160(3)
4109 0160
4P
3P 9573 3180
1800 A
1509 4160(3)
4P 9573 4180
3P 9573 3200
2000 A
4P 9573 4200
3P 9573 3250
2500 A included included
4P 9573 4250
3P 9573 3320
3200 A
4P 9573 4320
References
Key handle
3 position Door protective Mounting Remote control
Rating (A) No. of poles ATyS p DC power supply interlocking
padlocking surround spacers interface
system
3P 9573 3012
125 A
4P 9573 4012
3P 9573 3016
160 A
4P 9573 4016
3P 9573 3020
200 A
4P 9573 4020
3P 9573 3025
250 A
4RHMFKNBJ
4P 9573 4025 1.-(2$+ /
(1)
1599 0003 1539 0012 1 set of 2 spacers
in position 0
3P 9573 3031 1509 0001
315 A
1509 1006(1)
4P 9573 4031
3P 9573 3040
400 A
4P 9573 4040
12 VDC / 230 VAC
3P 9573 3050 1599 5012
500 A
24 VDC / 230 VAC
4P 9573 4050
1599 5112
3P 9573 3063 ATyS D20
630 A
9599 2020
4P 9573 4063 +
RJ45 cable
3P 9573 3080
connection
800 A
4P 9573 4080 1599 2009
3P 9573 3100
1000 A
4P 9573 4100
3P 9573 3120
1250 A
4P 9573 4120
3P 9573 3160
1600 A
4RHMFKNBJ
4P 9573 4160 1.-(2$+ /
1599 0004(1) 1539 0080
in position 0
3P 9573 3180
1800 A
1509 1004(1)
4P 9573 4180
3P 9573 3200
2000 A
4P 9573 4200
3P 9573 3250
2500 A
4P 9573 4250
3P 9573 3320
3200 A
4P 9573 4320
Accessories
Terminal shrouds
Changeover
Use Advantages
switches
IP2X protection against direct contact with Perforations allow remote thermographic
terminals or connecting parts. inspection without the need to remove the
shrouds.
Rating (A) No. of poles Position Reference
acces_206_a_2_cat
125 200 3P SNOANSSNLEQNMS(QD@Q(( 2694 3014(1)(2)
125 200 4P SNOANSSNLEQNMS(QD@Q(( 2694 4014(1)(2)
250 400 3P SNOANSSNLEQNMS(QD@Q(( 2694 3021(1)(2)
250 400 4P SNOANSSNLEQNMS(QD@Q(( 2694 4021(1)(2)
500 630 3P SNOANSSNLEQNMS(QD@Q(( 2694 3051(1)(2)
500 630 4P SNOANSSNLEQNMS(QD@Q(( 2694 4051(1)(2)
(1) To shroud front switch top and bottom 2 references required.
(2) To fully shroud front, rear, top and bottom 4 references required.
Terminal screens
Use
Top and bottom protection against direct For upstream and downstream protection,
contact with terminals or connection parts. order the reference once.
acces_207_a_2_cat
125 200 3P top / bottom 1509 3012
125 200 4P top / bottom 1509 4012
250 400 3P top / bottom 1509 3025
250 400 4P top / bottom 1509 4025
500 630 3P top / bottom 1509 3063
500 630 4P top / bottom 1509 4063
800 1250 3P top / bottom 1509 3080
800 1250 4P top / bottom 1509 4080
1600 1800 3P top / bottom 1509 3160
1600 1800 4P top / bottom 1509 4160
2000 3200 3P top / bottom 1509 3200
2000 3200 4P top / bottom 1509 4200
!QHCFHMFA@QR
Use
For bridging power terminals on the top or bottom side of the switch.
.MDOHDBDQDPTHQDCODQONKD
acces_205_a_2_cat
acces_226_b_1_x_cat
Q@SHMFR%HF
@MC%HF
www.socomec.com.
SNONQANSSNLAQHCFHMFBNMMDBSHNM%HF
For 3200 A rating, the connection pieces
O@QS @QDCDKHUDQDCAQHCFDCEQNLE@BSNQX
252
74 74
Top or bottom flat connection - Fig. 1 37 37 60
acces_232_a_1_cat
Quantity to order
Rating (A) Piece Reference
per pole(1)
155
129
2000 2500 Connection - part A 2 2619 1200
2000 2500 !NKSRDSO@QS! 2 2699 1200
Fig.2
3200 Connection - part A included
acces_228_b_1_x_cat
3200 !NKSRDSO@QS! 2 2699 1200
Quantity to order
Rating (A) Piece Reference
per pole(1)
acces_233_a_1_cat
3200 T piece - part C 2 2629 1200(2)
210
Quantity to order
Rating (A) Piece Reference Fig. 3
per pole(1)
acces_230_b_1_x_cat
2000 2500 !NKSRDSO@QS! 2 2699 1200 B
2000 2500 !@QO@QS$ 1 4109 0250(2)
2000 2500 T piece - part C 1 2629 1200(2)
A
BBDRRNQHDRBNMSHMTDC
Autotransformer 400/230 VAC
Use Rating (A) Reference
For applications without neutral, this autotransformer provides the 230 VAC 125 3200 1599 4064
required to power these ATyS products.
DC power supply
Use Rating (A) Operating voltage Reference
Allows an ATyS to be supplied from a 12 or 24 VDC source. 125 1800 12 VDC / 230 VAC 1599 5012
To be positioned as close as possible to the DC power supply source. 125 1800 24 VDC / 230 VAC 1599 5112
atys_606_a_1_cat
Routing of the conductors is controlled, integrate the power supply.
which means that no specific protective
device is necessary for these connections.
atys_603_a_2_cat
1250 1559 3120
1600 1800 1559 3160
2000 3200 1559 3200
atys_595_a_2_cat
For
Rating (A) Reference
125 630 1529 0012
800 1800 1529 0080
Auxiliary contact
Use
Pre-breaking and signalling of positions Low level auxiliary contacts: Please consult us.
I and II. Each reference provides a single If additional auxiliary contacts are required
E@BSNQXEHSSDC-.-"BNMS@BSENQANSG please consult us.
acces_065_a_1_cat
positions.
Mounting spacers
Use This accessory may also be used to replace
Increases the distance between the rear the original mounting spacers.
atys_009_a_2_cat
ONVDQSDQLHM@KR@MCSGDA@BJOK@SDAXLL
security by preventing unauthorised use of required the -K should not be added to the
product. product reference.
This is a factory fitted option which must be
requested when ordering the ATyS switch
3X2 3X2CSF@MCO
3NNQCDQSGHRNOSHNM
simply add -K after the ATyS reference.
ONRHSHNMO@CKNBJHMF(((
Use Rating (A) Reference
Enables the ATyS to be padlocked in
atys_854_a_1_cat
BBDRRNQHDRBNMSHMTDC
Key handle interlocking system
Use
With the product in manual mode, it enables +NBJHMFHM@KKSGQDDONRHSHNMR(((QDPTHQDR
KNBJHMFHMONRHSHNMTRHMF@1.-(2$+ / in addition, the "3 position padlocking"
KNBJE@BSNQXEHSSDC
accessory.
atys_853_a_1_cat
Rating (A) Reference
125 630 1509 1006
800 3200 1509 1004
Current transformers
Use - For ATyS p only
4RDCVHSG 3X2ORVHSBGDRBTQQDMS
transformers enable information to be
obtained on the load current.
trafo_077_b_1_cat
Reference
trafo_025_a_2_cat
See page 488.
atys_016_c_1_cat
$SGDQMDSBNLLTMHB@SHNM
12)!42,.#!42F@SDV@X
4825 0204
DLADCCDC$SGDQMDSVDARDQUDQRNESV@QD
Analogue outputs 4825 0093
Pulse outputs 4825 0090
Remote interfaces
Use ATyS D20 - for ATyS p
To display source availability and position In addition to the functions of
indication on the front of a panel. SGD 3X2#SGD#CHROK@XR
Interfaces are powered from the ATyS measurements and enables ATyS p mode
changeover switch, via the RJ45 control and configuration from the front of
a panel. Protection degree: IP21.
atys_564_d_1_cat
atys_565_d_1_cat
connection cable.
Maximum connection distance: 3 m.
Door mounting
ATyS D10 - for ATyS d, t and g 2 holes 22.5. ATyS changeover switch
To display source availability and position connection via RJ45 cable, not isolated.
indication on the front panel of an Cable available as an accessory.
Interfaces are powered from the ATyS. Drillings
enclosure. Protection degree: IP21.
96 x 96 22.5
atys_161_a_1_x_cat
36
atys_597_a_1_cat
Description of accessories Reference
40
ATyS D10 9599 2010
20
ATyS D20 9599 2020
= =
acces_209_a_2_cat
For ATyS d, t, g and p
Type Length Reference
RJ45 cable 3m 1599 2009
Sealable cover
Use - for ATyS t and g
atysm_043_a_2_cat
Prevents access to the ATyS t and g
configuration potentiometers and DIP switches
RD@KRRTOOKHDC
800 to 3200 A
Thermal current Ith at 40C 800 A 1000 A 1250 A 1600 A 1800 A 2000 A 2500 A 3200 A
1@SDCHMRTK@SHNMUNKS@FD4i5 1000 1000 1000 1000 1000 1000 1000 1000
1@SDCHLOTKRDVHSGRS@MCUNKS@FD4impJ5 12 12 12 12 12 12 12 12
Courants assigns demploi Ie (A) selon CEI 60947-3
Rated voltage Utilisation category A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1) A/B(1)
415 VAC " "! 800/800 1000/1000 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3200/3200
415 VAC " "! 800/800 1000/1000 1250/1250 1600/1600 1800/1800 -/2000 -/2500 -/3200
415 VAC " "! 800/800 1000/1000 1250/1250 1600/1600 1600/1600 -/2000 -/2500 -/3200
415 VAC " "! 800/800 1000/1000 1250/1250 1250/1250 1250/1250 -/1600 -/1600 -/1600
500 VAC " "! 800/800 1000/1000 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3200/3200
500 VAC " "! 800/800 1000/1000 1250/1250 1600/1600 1600/1600 -/2000 -/2500 -/3200
500 VAC " "! 630/630 800/800 1000/1000 1000/1000 1000/1000
500 VAC " "! 400/400 630/630 800/800 800/800 800/800
690 VAC " "! 800/800 1000/1000 1250/1250 1600/1600 1800/1800 2000/2000 2500/2500 3200/3200
690 VAC " "! 800/800 1000/1000 1250/1250 1600/1600 1600/1600 -/2000 -/2500 -/3200
690 VAC " "! 630/630 800/800 1000/1000 1600/1600 1600/1600
690 VAC " "! 400/400 630/630 800/800 1000/1000 1000/1000
220 VDC #" #"! 800/800 1000/1000 1250/1250 1600/1600 1800/1800
220 VDC #" #"! 800/800 1000/1000 1250/1250 1250/1250 1250/1250
220 VDC #" #"! 800/800 1000/1000 1250/1250 1250/1250 1250/1250
220 VDC #" #"! 800/800 1000/1000 1250/1250 1250/1250 1250/1250
440 VDC #" #"! 800/800 1000/1000 1250/1250 1600/1600 1800/1800
440 VDC #" #"! 800/800 1000/1000 1250/1250 1250/1250 1250/1250
440 VDC #" #"! 800/800 1000/1000 1250/1250 1250/1250 1250/1250
440 VDC #" #"! 800/800 1000/1000 1250/1250 1250/1250 1250/1250
Rated operational currents Ie (A) according to IEC 60947-6-1
Rated voltage Utilisation category
415 VAC "! 800 1000 1250 1600 1800 2000 2500 3200
415 VAC "! 800 1000 1250 1600 1600 2000 2000 2000
415 VAC "! 800 800 800 1000 1000 1250 1250 1250
Fuse protected short-circuit withstand as per IEC 60947-3 at 415 VAC
/QNRODBSHUDRGNQSBHQBTHSBTQQDMSJ QLR 50 100 100 100 100
RRNBH@SDCETRDQ@SHMF 800 1000 1250 2x800 2x800
Circuit breaker protected short-circuit withstand with any circuit breaker that ensures tripping in less than 0.3s(3)
1@SDCRGNQSSHLDVHSGRS@MCBTQQDMS
R(BVJ QLR 47 64 64 78 78 78 78 78
Short-circuit withstand without protection as per IEC 60947-3 at 415 VAC
1@SDCRGNQSSHLDVHSGRS@MCBTQQDMSR(BVJ QLR 26 35 35 50 50 50 50 50
Rated short-circuit making capacity 48 73.5 73.5 110 110 110 110 110
1@SDCRGNQSSHLDVHSGRS@MCBTQQDMSLR(BVJ QLR@RODQ($"
16 20 25 32 32 40 50 50
60947-6-1 at 415 VAC
Connection
,@WHLTL"TB@AKDBQNRRRDBSHNMLL 2 x 185 2 x 240
,HMHLTL"TATRA@QBQNRRRDBSHNMLL 2 x 40 x 5 2 x 50 x 5 2 x 60 x 5 2 x 80 x 5 3 x 100 x 5 2 x 100 x 10 2 x 100 x 10 2 x 100 x 10
,@WHLTL"TB@AKDBQNRRRDBSHNMLL 2 x 300 4 x 185 4 x 185 6 x 185 6 x 185
,@WHLTL"TATRA@QVHCSGLL 63 63 63 100 100 100 100 100
3HFGSDMHMFSNQPTDLHMHL@WH-L 20/26 20/26 20/26 40/45 40/45 40/45 40/45 40/45
Switching time (Standard setting)
(((NQ(((R 2.6 2.6 2.6 2.6 2.6 2 2 2
(NQ((R 1.6 1.6 1.6 1.6 1.6 1 1 1
#TQ@SHNMNEDKDBSQHB@KAK@BJNTS(((RLHMHLTL 1.5 1.5 1.5 1.6 1.6 1 1 1
Power supply
LHML@W5 " 166/332 166/332 166/332 166/332 166/332 166/332 166/332 166/332
Control supply power demand
/NVDQRTOOKX5 "HMQTRGMNLHM@K5 3X2 460/184 460/184 460/184 460/230 460/230 812/322 812/322 812/322
/NVDQRTOOKX5 "HMQTRGMNLHM@K5 3X2CSFO 482/206 482/206 482/206 482/252 482/252 834/344 834/344 834/344
Mechanical characteristics
#TQ@AHKHSXMTLADQNENODQ@SHMFBXBKDR
6DHFGS 3X2/JF 27.9 28.4 28.9 33.1 33.1 50.7 50.7 61.0
6DHFGS 3X2/JF 32.2 32.9 33.6 39.4 39.4 61.6 61.6 75.3
6DHFGS 3X2C/JF 28.5 29.0 29.5 33.7 33.7 51.3 51.3 61.6
6DHFGS 3X2C/JF 32.8 33.5 34.2 40.0 40.0 62.2 62.2 75.9
6DHFGS 3X2SFO/JF 29.0 29.5 30.0 34.2 34.2 51.8 51.8 62.1
6DHFGS 3X2SFO/JF 33.3 34.0 34.7 40.5 40.5 62.7 62.7 76.4
(1) Category with index A = frequent operation - Category with index B = infrequent operation. (3) Value for coordination with any circuit breaker that ensures tripping in less than 0.3s.
(2) 3-pole device with 2 poles in series for the "+" and 1 pole for the "-". 4-pole device with For coordination with specific circuit-breaker references, higher short-circuit current values
ONKDRHMRDQHDRAXONK@QHSX
are available. Please consult us.
301 3022 5 : closure of this contact enables the position control orders
6 : product availability relay
6 7 8 9 7 : auxiliary contact, closed when the switch is in position II
312 313 314 315 316 317 63A 64A 24 14 04 13 8 : auxiliary contact, closed when the switch is in position I
9 : auxiliary contact, closed when the switch is in position 0
5 4 3 2 1
ATyS d
1 preferred source
2 alternate source
1 2
1 : position 0 control
2 : position 1 control
3 : position II control
4 : priority control position 0
1022 101
201 2022
atys_826_a_1_x_cat
ATyS t
1 preferred source
2 alternate source
2 1
1 : position 0 control
F2 F1 2 : position 1 control
3 : position II control
201 202
102 101
N
L2
L3
L2
switch is in position II
8 : auxiliary contact, closed when the
63B 64B 417 416 415 414 413
15
14
switch is in position I
13 9 : auxiliary contact, closed when the
12 switch is in position 0
10 : remote display D10
11 : electronic unit availability relay
11 12 : automatic operation inhibited
atys_827_a_1_x_cat
5 4 3 2 1
ATyS g
1 preferred source
2 alternate source
1 : position 0 control
2 1
2 : position 1 control
3 : position II control
F2 F1 4 : priority control position 0
5 : closure of this contact enables the
201 202
102 101
position control orders
6 : motorisation unit availability relay
203 204 205 206
N
7 : auxiliary contact, closed when the switch
L2
L3
is in position II
L3
L2
8 : auxiliary contact, closed when the switch
L1
N
is in position I
207 208 209 210
16 63B 64B 417 416 415 414 413 15 9 : auxiliary contact, closed when the switch
14 is in position 0
17
13 10 : remote display D10
12
11 : electronic unit availability relay
19 12 : automatic operation inhibited
72 71 74
RJ
ATyS p
1 preferred source
2 alternate source
1 : position 0 control
2 1 2 : position 1 control
3 : position II control
F2 F1 4 : priority control position 0
5 : closure of this contact enables the position
201 202
102 101
control orders
6 : motorisation unit availability relay
203 204 205 206
L3
position II
L3
L2
position I
207 208 209 210
15
16 9 : auxiliary contact, closed when the switch is in
14
17 22 position 0
13
18 12 10 : remote control interface D20
19 11 : electronic unit availability relay
72 71 74
11
12-17 : programmable inputs
20 18 : auxiliary power supply for the use of optional
10 modules
21
RJ
atys_829_b_1_x_cat
FDMDQ@SNQRS@QSHMF@MCRSNOOHMFNQCDQ-"
6 7 8 9
FDMDQ@SNQRS@QSHMF@MCRSNOOHMFNQCDQ-.
21 : 4 slots for optional modules
312 313 314 315 316 317 63A 64A 24 14 04 13
22 : current transformer connection
5 4 3 2 1
Dimensions
ATyS 125 to 630 A
J
M J1 3
U
4 1. Locking bracket with 3
W padlocks max
2. Maximum handle radius,
CA
270
3. Connection and disconnection
119
6
area
=
Fix. 195
Fix. 180
4. Spacers
101
AC
BA
AA
223
5. Terminal shrouds
=
6. Handle
120
140
V
CA
10.5 Y Y 48
2 3
88
10 X T T T 11 Z1
3 5
Z2
atys_837_a_1_x_cat
A H
C
Fix. 195
Fix. 180
W 1
7
CA
9 U
Terminal Switch
Overall dimensions Body Connection
Rating (A) shrouds mounting
A 3p. A 4p. C AC F 3p. F 4p. H J 3p. J 4p. J1 M 3p. M 4p. T U V W X 3p. X 4p. Y Z1 Z1 AA BA CA
125 304 334 244 233 286.5 317 151 154 184 34 120 150 36 20 25 9 28 22 3.5 38 134 135 115 10
160 304 334 244 233 286.5 317 151 154 184 34 120 150 36 20 25 9 28 22 3.5 38 134 135 115 10
200 304 334 244 233 286.5 317 151 154 184 34 120 150 36 20 25 9 28 22 3.5 38 134 135 115 10
250 345 395 244 288 328 378 152 195 245 35 160 210 50 25 30 11 33 33 3.5 39.5 133.5 160 130 15
315 345 395 244 288 328 378 152 195 245 35 160 210 50 25 30 11 33 33 3.5 39.5 133.5 160 130 15
400 345 395 244 288 328 378 152 195 245 35 160 210 50 35 35 11 33 33 3.5 39.5 133.5 170 140 15
500 394 454 320.5 402 377 437 221 244 304 34 210 270 65 45 50 13 42.5 37.5 5 53 190 260 220 20
630 394 454 320.5 402 377 437 221 244 304 34 210 270 65 45 50 13 42.5 37.5 5 53 190 260 220 20
U
250
V
6
169
=
250
200
AC
AA
B
280
=
166
166
atys_838_a_1_x_cat
2 Y 5 Y 48
12.5 X T T T 12.5 3
F Z1 3
253.5 94
1
1. Locking bracket with 3 padlocks max 293
2. Maximum handle radius, operating angle 2 x 90. 391.5
3. Connection and disconnection area
4. Terminal screens
5. Inter phase barrier
6. Handle
Overall Terminal
Body Switch mounting Connection
Rating (A) dimensions shrouds
B AC F 3p. F 4p. J 3p. J 4p. M 3p. M 4p. T U V X Y Z1 AA
800 370 461 504 584 306.5 386.5 255 335 80 50 60.5 47.5 7 66.5 321
1000 370 461 504 584 306.5 386.5 255 335 80 50 60.5 47.5 7 66.5 321
1250 370 461 504 584 306.5 386.5 255 335 80 60 65 47.5 7 66.5 330
1600 380 531 596 716 398.5 518.5 347 467 120 90 44 53 8 67.5 288
1800 380 531 596 716 398.5 518.5 347 467 120 90 44 53 8 67.5 288
II
A
M 51.5 569 90
90
125
330
461
258
250
380
I
50
atys_839_a_1_x_cat
4 6,5
50
31
Cut of dimensions
ATyS 125 to 630 A ATyS 800 to 1800 A
ATyS ATyS d, t, g, p ATyS ATyS d, t, g, p
138
138 20
20
138
20
138
20
214
165
atys_840_a_1_x_cat
atys_841_a_1_x_cat
atys_842_a_1_x_cat
atys_843_a_1_x_cat
150
101
50.5
50.5
50.5
50.5
Connection terminals
ATyS 800 to 1000 A ATyS 1250 A ATyS 1600 to 3200 A
9 16 x 11 12.5
5 5
12.5
15 28.5
10 33
svr_098_a_1_x_cat
15
svr_077_a_1_x_cat
svr_078_b_1_x_cat
15
25 25
8.5 33 8.5 15.75 28.5 15.75 30 30
50 60 45 45
90
Strong points
ATyS C30 controller > Auxiliary power supply.
ATYS_599_C
General characteristics
ATyS C30 ATyS C40
q ATyS D10 or D20 connection available. q Dual genset controller with a redundant
q Inputs for auxiliary contact position genset application cycle (basic cycle).
information. q 1U measurement on each source -
q 3U measurement on network 1 and 1U on generator 1 & generator 2.
network 2. q 3 programmable inputs for the following
q 2 programmable inputs for the following functions: start/stop transfer cycle, manual
functions: test on/off load, manual retransfer, automatic inhibit
retransfer, priority source selection, q 1 programmable output for the following
automatic inhibit ETMBSHNMRRNTQBD@U@HK@AHKHSXHMENQL@SHNM
q Up to 2 programmable outputs for the and circuit breaker control.
following functions: source availability q 2 generator control contacts
information, load shedding relay and circuit (Gen1 & Gen2).
breaker control.
q 1 relay output for generator control.
Advantages
Auxiliary power supply Extended compatibility of use
Two versions of the ATyS C30 are available. The product is used with Socomec
One version with an AC supply via the changeover switches, or those using identical
measurement inputs and another with a DC technology. It is also compatible with
auxiliary supply. contactor and circuit breaker technologies.
Modular device
The ATyS C30 and C40 are modular products
(6 modules, 105 mm wide) which can be DIN rail
mounted.
Configurations
ATyS C30: ATyS C40:
Transformer/transformer and transformer/generator applications Generator/generator applications
4 5
ATyS C30 ATyS ATyS C40
D10/D20
3 4 3 3
G1 1 1 G2
1 2 2
atys_566_c_1_x_cat
atys_149_g_1_x_cat
ATyS S ATyS S
ATyS Sd ATyS Sd
ATyS ATyS
ATyS d ATyS d
ATyS M3s ATyS M3s
Electrical characteristics
Supplied from measurement circuit 110 400 VAC
DC power supply 9 30 VDC
Measurement range v5 "
Frequency 50/60 Hz
Accuracy
Terminals
6 7 8 9 10 6 7 8 9 10
ATyS C30 ATyS C40
13 13
13 14 23 24 33 34 43 44 53 54 301302 303 304 305 306 DC- DC+ 13 14 23 24 33 34 43 44 53 54 301 302 303 304 305 306 DC- DC+
atys_567_b_1_x_cat
atys_418_c_1_x_cat
1 2 3 4 5 1 2 3 4 5
11 12 11 12
N L3 L2 L1 L1 L3 L3 L1 L1 L3
103 104 105 106 203 205 104 106 203 205
1. Generator start / stop control 9. I1: programmable input 1. Generator G1 start / stop control 8. AC2: auxiliary contact position 2
2. Position 1 control 10. I2: programmable input 2. Position 1 control 9. I1: programmable input
3. Position 2 control 11. Source 1 : 3 U network 3. Position 2 control 10. I2: programmable input
4. O1: programmable output measurement and power supply
4. O1: programmable output 11. Generator G1 : 1U measurement
5. O2: programmable output 12. Source 2 : 1 U network
5. Generator G2 start / stop control 12. Generator G2 : 1U measurement
6. AC1: auxiliary contact position 1 measurement and power supply
6. AC1: auxiliary contact position 1 13. DC power supply 9-30 VDC
7. AC1: auxiliary contact position 0 13. DC power supply 9-30 VDC
(version 1599 3031) 7. I3: programmable input
8. AC0: auxiliary contact position 2
References
ATyS C30 ATyS C40
Type Reference Reference
Supplied from measurement circuit 1599 3030
DC power supply 1599 3031 1599 3040
RETROFIT
Line
p. 468
CORPO 213A
O pti mi
q Significantly reduce your energy costs.
q Easily communicate internally and
externally your environment oriented
se
actions.
se
ly
a
An
The three steps in the Energy Efficiency policy.
VERTE 108 A
SYDIV 111 A
Save time, reduce space and have peace of mind by choosing We offer a range of services to
Socomec. help you identify and meet your
energy performance objectives:
Compact devices: from single Guaranteed connections:
- assessment and sizing,
COMPACT DIN 1 module meters to 96x96 protection against
DESIGN ROBUST - commissioning,
multifunction measurement OG@RDMDTSQ@KHMUDQRHNM
devices, our products are and wiring errors detection, - software adaptation and
compact. commissioning is faster and customisation,
the equipment is guaranteed to - customised maintenance,
operate correctly.
- end-of-life product
Robust terminals: we only Intuitive ergonomics: replacement,
QUICK use high quality cable lugs with
CONFIGURATION
Socomec products are - customised training.
appropriate tightening torques. designed to reduce the
configuration time. Contact your agency for
further information.
Reliable ranges: our ranges
RELIABLE
always respect the major
international standards such
@R($"
($"/,#@MC
$-,(#
Specifiers
The assurance of an adapted solution that conforms to the most
stringent standards.
Solutions adapted to Products compliant with major
ADAPTED your requirements: our IEC standards:
SOLUTION COMPLIANT
comprehensive offer helps you - All DIRIS devices comply with
find the perfect product with the requirements of the IEC
the needed functions. 61557-12. This guarantees a
In addition: high level of performance in
- We help you to define the metrological, mechanical and
right system perfectly suited environmental terms.
to your customer needs. - All COUNTIS comply with
- As a specialist manufacturer the requirements of the MID
we are able to adapt our directive B+D module
devices to your specific (EN 50470-1, EN 50470-3
needs. ensuring measurement
accuracy and products are
tamper-proof.
Our offer, comprising products, software and services are perfectly Take advantage of a complete manufacturers offer that is flexible
suited to LV electrical installations, but also are an ideal solution for and multi-utility compatible, and one that provides:
HV facilities thanks to the DIRIS A and DIRIS N measuring units. q cost-effective products: COUNTIS E energy meters with direct
In addition, the flexibility of our products and their extensive ranges connection up to 100 A, COUNTIS ECi multi-utility pulse collector
enable contractors and users to choose the right product for each type (electricity, water, gas, analogue values, etc.),
of network (single, three-phase, etc.) and the load to be measured. q advanced products: DIRIS A multifunction measuring units and
DIRIS N network analysers,
q indispensible range accessories: current transformers,
measurement indicators, communication interfaces, etc.
DIRIS N
COUNTIS COUNTIS
DIRIS E00 COUNTIS
E00 A40 E40
DIRIS
A10
M
DIRIS
A20
COUNTIS
Water, gas, air
COUNTIS E30 Gateway
ECi TCP/IP RS485
CO
UN
TIS
COUNTIS
E 50
CO
UN
TIS
E Ci3
E50 PLC
Gateway
TCP/IP RS485
B TM
M
C
S
/
mesur_112_c_fr_cat
VERTELIS software
Selection guide
VERTELIS
Supervision )6
?
01/03/
10
02/03/
10
03/03/
10
VISION
DIRIS N
analysis
+
Power DIR
IS
A20
DIRIS A
monitoring TEST
I
V
F
OK
P
PF
& RETROFIT Line
+
E
PROG
Energy COUNTIS E
& RETROFIT Line
DIRIS 887 C
metering
Active energy meters: COUNTIS E E00 / E02 E03 / E04 E10 / E11 / E12 E13 / E14 E15 / E16 E20 / E21 E23 / E24
p. 420 p. 420 p. 422 p. 422 p. 422 p. 424 p. 424
Main specifications
0,'(1bPRGXOH%'FHUWLILFDWLRQ ( ( ( ( ( (
5602'%86
560%86
&DVH PRGXOH PRGXOH PRGXOHV PRGXOHV PRGXOHV PRGXOHV PRGXOHV
Functions
7RWDOSDUWLDOHQHUJ\N:K ((
$FWLYHSRZHU5HDFWLYHSRZHU
'XDOWDULIIIRUN:K (( (
7RWDOSDUWLDOHQHUJ\NYDUK
N9$
/RDGFXUYH
0HDVXUHPHQW,9346)DQG3)YLD
FRPPXQLFDWLRQ
&7FRQQHFWLRQLQGLFDWLRQ
%LUHFWLRQDOHQHUJ\FRQVXPSWLRQDQGSURGXFWLRQ
Accuracy
$FWLYHHQHUJ\,(& FODVV FODVV FODVV FODVV FODVV FODVV FODVV
5HDFWLYHHQHUJ\DFFRUGLQJWR,(&
$FWLYHHQHUJ\(1b FODVV%( FODVV%( FODVV%( FODVV%( FODVV%( FODVV%(
Characteristics
0HWURORJLFDO/('
3XOVHRXWSXW :K :K :K :K :K :K :K
6HDOLQJFRYHU0,'YHUVLRQRQO\ ( ( ( ( ( (
3KDVHQHXWUDOLQYHUVLRQSURWHFWLRQ
E25 / E26 E30 / E31 / E32 E33 / E34 E35 / E36 E63 E40 / E41 / E42 E43 / E44 E45 / E46 E50 E53
p. 424 p. 426 p. 426 p. 426 p. 432 p. 428 p. 428 p. 428 p. 430 p. 430
( ( ( (
FODVV FODVV FODVV FODVV FODVV FODVV FODVV FODVV FODVV FODVV
FODVV FODVV FODVV FODVV FODVV
FODVV%( FODVV%( FODVV%( FODVV%( FODVV&( FODVV&( FODVV&(
:K :K :K FRQILJXUDEOH
( ( ( ( ( ( (
CO
UN
TIS
E 63
CO
UN
TIS
485 PC
E Ci3
232
Which Which
application? functions?
& power quality
Multifunction metering
Applications
(MFM)
n ew
As standard:
As standard:
1 logical input for pulse
1 input for tariff selection/
metering or remote device 1 programmable output for
remote device status
status pulse report, alarm report
1 programmable output for
1 programmable output for or remote device command
pulse report, alarm report
pulse report, alarm report RS485 JBUS/MODBUS
or remote device command
or remote device command communication
RS485 JBUS/MODBUS (for
RS485 MODBUS
1 reference)
(for 2 references)
Which
Which Which
communication
dimensions? options?
protocol?
Power monitoring Power monitoring & Power monitoring & residual current Power quality & network analysis
(PMD) events analysis (PMD) monitoring (PMD+RCM) (PQA)
by temperature sensor by temperature sensor by temperature sensor internal + by temperature sensor
optional optional
100
to
400
250
to
200 * 200 1000 250
to 300 to to
1600 to 1600 300 1500
400 to 400
1500 to to
2000 *
2000 2000 1000 400
750 600 to
to
to to 4000 1200
1000 * 1500 to
3000 to 4000 1200
2000 1000
3000 to to
3000 5000
105.5 123.5 184.8 184.8 129 117 167 150 175 106 158 198 243
96 120 172 172 88 96 129 99 100 93 125 155 195
58 58 52 52 48 68 78 58 55 58 58 58 79
44 55 85 100
63x10 80x10 100x10 123x30 60x30 84x34 100x55 103x41 128x38 33x23 85x55 125x85 165x85
50x10 (x2) 60x30 80x10 (x3) 100x10 (x3)
60x10 (x2)
Which
Which function?
characteristics?
& power quality
Analogue devices
AC and DC measurements
p. 506
Characteristics
Type DIN - ROTEX - MODULAR
Scale, display or output Deviation 90 and 240
Mounting Panel or modular DIN rail mounting
Dimensions 48x48 - 72x72 - 96x96 - 144x144 (mm)
AC measurement
Direct from 1 to 100 A Standard, thermal or changeover switch
Current measurement Via a CT (1A or 5A) ammeter
Scale: In; 1.2 In; 5 In
Direct from 6 to 600 V Scale: Un; 1.2 Un
Voltage measurement Via a VT with a 100 or 110V secondary Standard or changeover switch voltmeter
Voltage from 40 to 440 V Scale: 0.8 cap - 1 - 0.2 ind or 0.5 cap - 1 -
Power factor measurement Direct or via a CT (1A or 5A) 0.5 ind
or 0 cap - 1 - 0 - 1 ind
Voltage from 40 to 440 V Scale: Pn; 1.2Pn; Qn; 1.2Qn
Active and reactive power measurement Direct or via a CT (1A or 5A)
Pulse and hour counters Voltage from 12 to 400 VAC with or without reset
DC measurement
Direct from 50 wA to 50 A On shunt 60 mV; 100 mV;150 mV
Current measurement
Pulse and hour counters Voltage from 2 to 220 VDC with or without reset
Synchronisation devices Other electrical values
Phase meters Navy applications
Other measurements
Temperature measurement Railway applications
Threshold indicators
Customised solutions
Scale and calibration
Sectors and coloured marking
IP54 - IP65 - Tropicalisation
Customising
Anti vibrations
DG - DGM - DG2M CS - CM -- CR
3 Digits to 4 Digits 1/2 Standard analogue output, RS 232 or RS 235
Panel mounting; Modular surface-mounted casing or modular DIN rail mounting; racks
72x36; 72x36; 72x72; 96x96 (mm) CS: 45, 75 or 150mm; CM: 3, 6 or 9 modules; CR 19
Direct from 1 to 5 A Standard, multi-indicators, RMS ammeter Direct from 1 to 5 A Output current 1, 5, 10, 20 mA and 4...20 mA
Via a CT (1A or 5A) programmable, threshold Via a CT (1A or 5A) Output voltage 1, 5, 10 V and 2...10V
Self-supplied or auxiliary power supply
Direct from 1.999 to 600 V Programmable, threshold, RMS or standard Direct from 40V to 400V Output current 1, 5, 10, 20 mA and 4... 20 mA
Via a VT with a 100 or 110V secondary voltmeter Via a VT with a 100 or 110V secondary Output voltage 1, 5, 10 V and 2...10V
Self-supplied or auxiliary power supply
Voltage from 40 to 600 V Frequencies 0-999.9 Hz and 40-999.9 Hz Voltage from 40 to 440 V Self-supplied or auxiliary power supply
Direct or via a CT (1A or 5A) Output current 1, 5, 10, 20 mA and 4... 20 mA
0.8 cap - 1 - 0.2 ind or 0.5 cap - 1 - 0.5 ind Output voltage 1, 5, 10 V and 2...10V
Voltage from 40 to 600 V 0 cap - 1 - 0 ind Voltage from 40 to 440 V Self-supplied or auxiliary power supply
Direct or via a CT (1A or 5A) Direct or via a CT (1A or 5A) Output current 1, 5, 10, 20 mA and 4... 20 mA
0.8 cap - 1 - 0.2 ind or 0.5 cap - 1 - 0.5 ind Output voltage 1, 5, 10 V and 2...10V
Voltage from 40 to 440 V Scale: Pn; 1.2Pn; Qn; 1.2Qn Voltage from 40 to 440 V Self-supplied or auxiliary power supply
Direct or via a CT (1A or 5A) Direct or via a CT (1A or 5A) Output current 1, 5, 10, 20 mA and 4... 20 mA
Scale: Pn; 1.2Pn; Qn; 1.2Qn Output voltage 1, 5, 10 V and 2...10V
Voltage from 40 to 400 VAC with or without reset
Direct from +/- 199.9 wA to +/- 1.999 A Programmable, threshold or standard ammeter Direct from 100 wA to 5 A Output current 1, 5, 10, 20 mA and 4... 20 mA
On shunt 60 mV; 100 mV; 150 mV On shunt 60 mV; 100 mV; 150 mV Output voltage 1, 5, 10 V and 2...10V
Self-supplied or auxiliary power supply
Direct from +/- 199.9 mV to +/- 600 V Programmable, threshold or standard voltmeter Direct from 10 mV to 440 V Output current 1, 5, 10, 20 mA and 4... 20 mA
On divider from 700 to 4000 VDC On divider from 700 to 4000 VDC Output voltage 1, 5, 10 V and 2...10V
Self-supplied or auxiliary power supply
Voltage from 2 to 48 VDC with or without reset
Temperature measurement Navy applications Transducers programmable with RS 232 or RS 485 Resistance measurement
Threshold indicators Railway applications Temperature measurement
Other electrical values Multi display
new >
>
Camping sites.
Marinas.
> Shopping centres.
> Data centres.
count_244_a_1_cat
count_215_a_1
Strong points
> Compact.
> Pulse output.
> MID certified B+D module.
COUNTIS E02 - MID COUNTIS E04
> RS485 communication
(MODBUS)
tamper-proof components to
Compact
prevent fraud.
The COUNTIS E0x is only 1 module wide.
Pulse output
The pulse output enables the kWh Conformity to standards
consumption to be reported to a remote COUNTIS E0x COUNTIS E0x
system (PC/BMS) so that it can be analysed > IEC 62053-21
for billing, energy saving or energy cost class 1
management purposes.
> IEC 62053-31
MID certified B+D module
COUNTIS E products with MID certification > IEC 62052-11
provide the guaranteed accuracy required for > EN 50470-1
applications in which sub-billing of the electrical Common characteristics > EN 50470-3
energy consumed is necessary. Module
B+D certification guarantees that the design q Compact design.
and manufacturing process of products are q ,D@RTQDLDMS@BBTQ@BX
approved by an accredited laboratory. q LCD display.
Front panel
1. Terminal shrouds (COUNTIS E02 + E04).
2. MID Marking (COUNTIS E02 + E04).
3. Metrological LED (2000 pulses/kWh for E00/E02 and
OTKRDRJ6GENQ$$
1 4. kWh display.
5. Serial number (COUNTIS E02).
4
2
count_215x_a_2_cat
Electrical characteristics
Current measurement (TRMS) Output (pulsed) COUNTIS E00/E02
Type single-phase - direct 32 A Number 1
Input consumption < 2 VA Type of optocoupler 15 VDC max
Permanent overload 32 A Fixed pulse weight 100 Wh
Intermittent overload 30 Imax for 10 ms Pulse duration 100 ms
Minimum current measured 20 mA Operating conditions
Voltage measurements (TRMS)
Operating temperature - 10 + 55 C
Range of measurement 196 264 VAC
Storage temperature - 20 + 70 C
Input consumption 8 VA
Relative humidity
Permanent overload 264 VAC
Energy accuracy Communication COUNTIS E03/E04
Active (according to IEC 62053-21) Class 1 Link RS485
Active (according to EN 50470) Class B Type 2 3 half duplex wires
Power supply Protocol MODBUS RTU
Self-supplied yes MODBUS speed 1200 38400 bauds
Case
17.5 / 19 61/63
47/49 COUNTIS E00/E02 COUNTIS E03/E04
Type modular modular
Number of modules 1 1
Dimensions W x H x D 17.5 x 85 x 61 19 x 87 x 63
Case degree of protection IP 20 IP 20
Front degree of protection IP 50 IP 50
85/87
45
Connection
N N
L L
L L
N N
+ -
count_213_b_1_x_cat
count_239_a_1_x_cat
References
COUNTIS E00 COUNTIS E02 COUNTIS E03 COUNTIS E04
Type Reference Reference Reference Reference
Direct 32 A 4850 3019
Direct 32 A - MID 4850 3020
Direct 32 A - with MODBUS communication via RS485 4850 3029
Direct 32 A - with MODBUS communication via RS485 - MID 4850 3030
count_246_a_1_cat
Strong points
RS485 communication (MODBUS MID certified B+D module > IEC 62053-21
or M-BUS) or pulse output COUNTIS E products with MID certification class 1
To enable the remote reporting of energy provide the guaranteed accuracy required for > IEC 62053-31
consumption, COUNTIS E1x are provided applications in which sub-billing of the electrical > IEC 62052-11
with either a pulse output or an RS485 energy consumed is necessary. Module
> EN 50470-1
communication output, with MODBUS or B+D certification guarantees that the design
M-BUS protocol. In addition to their reporting and manufacturing process of products are > EN 50470-3
functions, COUNTIS E1x with RS485 can be approved by an accredited laboratory.
configured remotely and enable access to
multi-measurement values.
Dual-tariff metering
Two tariffs are available and can be easily
accessed through the meters display. Each
tariff can be utilised to assign energy metering
to different time slots (high and low demand
hours) or different sources (normal/backup).
Models Key functions
E10 Pulse output
E11 Dual tariff (2 partial counters) + Pulse output
E12 Dual tariff + MID (Reset impossible) + Pulse output
E13 MODBUS RS485 communication
E14 MODBUS RS485 communication + MID (Reset impossible)
E15 M-BUS communication
E16 M-BUS communication + MID (Reset impossible)
Front panel
1. Terminal shrouds (COUNTIS E12).
2. Backlit LCD display.
1
3. MID Marking (COUNTIS E12).
4. Serial number (COUNTIS E12).
5. Navigation key.
2 5 6. Metrological LED (1000 pulses/kWh).
count_216x_a_2_cat
3 4
Electrical characteristics
Current measurement COUNTIS E10E12 COUNTIS E13E16 Output (pulsed) COUNTIS E10/E11/E12
single-phase single-phase Type of optocoupler IEC 62053-31 Class A (20 ... 30 VDC)
Type
direct 63 A direct 80 A Number 1
Input consumption 0.8 VA max. 0.8 VA max. Fixed pulse weight 100 Wh
Startup current (Ist) 40 mA 20 mA
Pulse duration 100 ms
Minimum current (Imin) 0.5 A(1) 0.25 A
Transition current (Itr) 1 A(2) 0.5 A Operating conditions COUNTIS E10E12 COUNTIS E13E16
Reference current (Iref) 10 A(3) 5A Operating temperature -10 to 55 C -25 to 55 C
Permanent overload (Imax) 63 A 80 A Storage temperature -20 to 70 C -25 to 70 C
Intermittent overload 1890 A max for 10 ms 2400 A max for 10 ms Relative humidity
Voltage measurement Communication COUNTIS E13/E14/E15/E16
Range of measurement 5
5
Link RS485
Consumption (VA) 0.5 VA max. 0.5 VA max.
Type 2 3 half duplex wires
Permanent overload 280 V phase-neutral 300 V phase-neutral
Energy accuracy Protocol MODBUS RTU
Active (according to IEC 62053-21) Class 1 Class 1 MODBUS speed 4800 38400 bauds
Power supply M-BUS speed 300 9600 bauds
Self-supplied yes (1) I(min)
(SQ
Frequency 50/60 Hz 3GD@BBTQ@BXBK@RRHRFT@Q@MSDDCADSVDDM(SQ@MC(max
(3) IQDE = IAA@RDBTQQDMS (SQENQCHQDBSBNMMDBSHNM".4-3(2
Case
62.5 / 64
COUNTIS E10E12 COUNTIS E13E16
54 45
Type modular modular
Number of modules 3 3
Dimensions W x H x D 54 x 90 x 62.5 mm 54 x 90 x 64 mm
COUNTIS E10
Case degree of protection IP 20 IP 20
Error Partial
Front degree of protection IP 51 IP 51
count_190_b_1_x_cat
90
45
63A
230VAC 50/60Hz 0.5-10(63)A
C=1Wh/imp Rigid cable cross-section 1.5 to 16 mm2 1.5 to 50 mm2
Flexible cable cross-section 1 to 16 mm2 1.5 to 50 mm2
Weight 170 g 170 g
Connection
N N N
L L L L L L
+ - 120 + - NC + - + -
count_181_c_1_x_cat
count_240_a_1_x_cat
count_241_a_1_x_cat
4 6 8 10 1 3 2 1 2 3 4 5 6 L1 L1 N 1 2 3 4 5 6 L1 L1 N
T1/2 L L N RS485 T1/2* T1/2
COUNTIS E10/E11/E12 COUNTIS E13/14 COUNTIS E15/16
-NS@U@HK@AKDNM".4-3(2$
References
COUNTIS E10 COUNTIS E11 COUNTIS E12 COUNTIS E13 COUNTIS E14 COUNTIS E15 COUNTIS E16
Type Reference Reference Reference Reference Reference Reference Reference
direct 63 A 4850 3000
direct 63 A - Dual tariff 4850 3001
direct 63 A - Dual tariff and MID 4850 3002
direct 80 A - with MODBUS communication via RS 485 4850 3031
direct 80 A - with MODBUS communication via RS 485 - MID 4850 3032
direct 80 A - wih M-BUS communication 4850 3033
direct 80 A - with M-BUS comminucation - MID 4850 3034
count_248_a_1_cat
count_232_a
Strong points
COUNTIS E20 COUNTIS E23
> RS485 communication
(MODBUS or M-BUS) or
pulse output.
Function Principle diagram
> Dual-tariff metering.
The COUNTIS E2x is a modular active > Detection of connection errors.
electrical energy meter displaying the energy
and power consumed (kWh and kW) directly > MID certified B+D module.
on its backlit LCD display. It is designed for
three-phase load metering and is used for
direct connections of up to 63 A.
Conformity to standards
Front panel
1. Backlit LCD display.
2. Navigation key.
3. Reset key.
4. Metrological LED (1000 pulses/kWh).
count_177x_b_1_cat
2
3
4
1
Electrical characteristics
Current measurement COUNTIS E20/E21 COUNTIS E23E26 Output (pulsed) COUNTIS E20/E21
three-phase three-phase
Type Number 1
direct 63 A direct 63 A
0.8 VA max. per 0.8 VA max. per Type of optocoupler IEC 62053-31 Class A (20 ... 30 VDC)
Input consumption Fixed pulse weight 100 Wh
phase phase
Startup current (Ist) 40 mA 15 mA Pulse duration 100 ms
Minimum current (Imin) 0.5 A(1) 0.25 A Operating conditions COUNTIS E20/E21 COUNTIS E23E26
Transition current (Itr) 1 A(2) 0.5 A Operating temperature -10 to 55 C -25 to 55 C
Reference current (Iref) 10 A(3) 5A
Permanent overload (Imax) 63 A 63 A Storage temperature -20 to 70 C -25 to 70 C
Intermittent overload 1890 A max for 10 ms 1890 A max for 10 ms Relative humidity
Voltage measurement Communication COUNTIS E23/E24/E25/E26
Range of measurement
5
5
Link RS485
Consumption (VA) 2 VA max. 2 VA max. Type 2 3 half duplex wires
280 V phase-neutral /
Permanent overload 276 V phase-neutral Protocol MODBUS RTU
480 V phase-phase
Energy accuracy MODBUS speed 1200 38400 bauds
Active (according to IEC 62053-21) Class 1 M-BUS speed 300 9600 bauds
Power supply
Self-supplied yes (1) I(min)
(SQ
Frequency 50 Hz 3GD@BBTQ@BXBK@RRHRFT@Q@MSDDCADSVDDM(SQ@MC(max
(3) IQDE = IAA@RDBTQQDMS (SQENQCHQDBSBNMMDBSHNM".4-3(2
Case
62.5 / 64
COUNTIS E20/E21 COUNTIS E23E26
72 45
Type modular modular
Number of modules 4 4
Dimensions W x H x D 72 x 90 x 62.5 mm 72 x 90 x 64 mm
COUNTIS E20 Case degree of protection IP20 IP20
count_191_b_1_x_cat
45
Connection
N N
L1 L1 L1 L1
L2 L2 L2 L2
L3 L3 L3 L3
count_182_b_1_x_cat
count_183_a_1_x_cat
+ - + -
2 4 6 1 3 5 7 9 11 2 4 6 8 10 1 3 5 7 9 11
N L1 L1 L2 L2 L3 L3 N T1/2 L1 L1 L2 L2 L3 L3
COUNTIS E20 COUNTIS E21
N N
L1 L1 L1 L1
L2 L2 L2 L2
L3 L3 L3 L3
count_242_a_1_x_cat
count_243_a_1_x_cat
120 - + NC + - + -
N 1 2 4 5 6 7 L1 L1 L2 L2 L3 L3 N 1 2 4 5 6 7 L1 L1 L2 L2 L3 L3
T1/2* RS485 T1/2
COUNTIS E23/E24 COUNTIS E25/E26
-NS@U@HK@AKDNM".4-3(2$
References
COUNTIS E20 COUNTIS E21 COUNTIS E23 COUNTIS E24 COUNTIS E25 COUNTIS E26
Type Reference Reference Reference Reference Reference Reference
direct 63 A - three-phase 4850 3003
direct 63 A - three-phase - Dual tariff 4850 3004
direct 63 A - with MODBUS communication via RS485 4850 3035
direct 63 A - with MODBUS communication via RS485 - MID 4850 3036
direct 63 A - with M-BUS communication 4850 3037
direct 63 A - with M-BUS communication - MID 4850 3038
> Industry.
> Infrastructure.
> Data centres.
count_219_a
Strong points
COUNTIS E32 - MID
4. Serial number
6 ".4-3(2$$ Permanent overload (Imax) 100 A
7 and E36). Intermittent overload 3000 A max for 10 ms
5. Navigation key. Voltage measurement
6. Reset key. Range of measurement
5
3 4 7. Metrological LED. Consumption (VA) 2
Permanent overload 280 V phase-neutral / 480 V phase-phase
Energy accuracy
Active (according to IEC 62053-21) Class 1
Case Active (according to EN 50470) Class B
Power supply
62.5 Self-supplied yes
126 45 Frequency 50 / 60 Hz
Output (pulsed)
Number 1
Type of optocoupler IEC 62053-31 class A (20 ... 30 VDC)
COUNTIS E30
Fixed pulse weight 100 Wh
count_192_b_1_x_cat
Error Partial
45
Operating conditions
RESET
100A
3X230(400)VAC 50/60Hz 0.5-20(100)A
C=2Wh / imp Operating temperature -10 to 55 C
Storage temperature -20 to 70 C
Relative humidity
Communication
Link RS485
Type 2 3 half duplex wires
Type modular Protocol MODBUS RTU / M-BUS
Number of modules 7 MODBUS speed vA@TCR
Dimensions W x H x D 126 x 90 x 62.5 mm M-BUS speed vA@TCR
Case degree of protection IP20 (1) I(min)
(SQ
Front degree of protection IP51 3GD@BBTQ@BXBK@RRHRFT@Q@MSDDCADSVDDM(SQ@MC(max
(3) IQDE = IAA@RDBTQQDMS (SQENQCHQDBSBNMMDBSHNM".4-3(2
Display type backlit LCD display
Rigid cable cross-section 2.5 to 35 mm2
Flexible cable cross-section 2.5 to 35 mm2
Weight 490 g
Connection
N N N
1 1 1
L1 L1 L1 L1 L1 L1
1 1 1
L2 L2 L2 L2 L2 L2
1 1 1
L3 L3 L3 L3 L3 L3
count_184_c_1_x_cat
count_188_e_1_x_cat
count_185_c_1_x_cat
+ - + - + -
2 4 6 1 3 5 7 9 11 2 15 17 13 1 3 5 7 9 11 2 4 6 8 10 1 3 5 7 9 11
N L1 L1 L2 L2 L3 L3 N RS485 L1 L1 L2 L2 L3 L3 N T1/2 L1 L1 L2 L2 L3 L3
COUNTIS E30 COUNTIS E33/E34/E35/E36 COUNTIS E31/E32
F& LETRDRL@W
References
COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS
E30 E31 E32 E33 E34 E35 E36
Type Reference Reference Reference Reference Reference Reference Reference
100 A direct 4850 3005
100 A direct - Dual tariff 4850 3006
100 A direct - Dual tariff - MID 4850 3007
100 A direct with RS485 MODBUS communication (1) 4850 3012
100 A direct with RS485 MODBUS communication - MID(1) 4850 3013
100 A direct with M-BUS communication (1) 4850 3025
100 A direct with M-BUS communication - MID(1) 4850 3026
Management software for COUNTIS See page 464
S@QHEERSGQNTFG12BNLLTMHB@SHNM
> Industry.
> Infrastructure.
> Data centres.
Strong points
6
7 6. Reset key. ,HMHLTLBTQQDMS(min) 50 mA(1)
8
,DSQNKNFHB@K+$#
Transition current (Itr) 250 mA(2)
8. Programming key. Reference current (Iref) 5 A(3)
3 4 Permanent overload (Imax) 6A
Intermittent overload 120 A for 0.5 s
Voltage measurement
Range of measurement
5
Case Consumption (VA) 2 VA
Permanent overload 280 V phase-neutral / 480 V phase-phase
62.5 Energy accuracy
72 45 Active (according to IEC 62053-21) Class 1
Active (according to EN 50470) "K@RR!
Power supply
Self-supplied yes
COUNTIS E40
Error Partial
Frequency 50 / 60 Hz
count_193_b_1_x_cat
Output (pulsed)
90
45
PROG
RESET
Number 1
3X230(400)VAC 50/60Hz 0.05-5(6)A
C=0.1Wh/imp Type of optocoupler IEC 62053-31 Class A (20 ... 30 VDC)
Pulse weight 100 Wh, 1 kWh, 10 kWh, 100 kWh
50 ms, 100 ms, 200 ms, 400 ms, 800 ms,
Pulse duration
1000 ms, 1500 ms
Operating conditions
Type modular Operating temperature -10 to 55 C
Number of modules 4 Storage temperature -20 to 70 C
Dimensions W x H x D 73 x 90 x 62.5 mm Relative humidity
Case degree of protection IP20 Communication
Front degree of protection IP51 Link RS485
Display type backlit LCD display Type 2 3 half duplex wires
Rigid cable cross-section 1.5 to 10 mm2 Protocol ,.#!42134,!42
Flexible cable cross-section 1 to 6 mm2 ,.#!42 speed 4800 38400 bauds
Weight 230 g ,!42RODDC 300 9600 bauds
(1) I(min)
(SQ
3GD@BBTQ@BXBK@RRHRFT@Q@MSDDCADSVDDM(SQ@MC(max
(3) IQDE = IAA@RDBTQQDMS (SQENQCHQDBSBNMMDBSHNM".4-3(2
Connection
Recommendation:
- For IT earthing systems, it is recommended that the CT secondary is not connected to earth.
- When disconnecting the COUNTIS, the secondary of each current transformer must be short-circuited. This operation can be carried out automatically by a
2.".,$"/3(@M@BBDRRNQXVGHBGHRHMBKTCDCHMSGHRB@S@KNFTD
/KD@RDQDEDQSNO@FD428
N N N
L1 L1 L1
L2 L2 L2
count_189_f_1_x_cat
count_187_d_1_x_cat
count_186_c_1_x_cat
L3 L3 L3
1 1 1 1 1 1 1 1 1
+ - + - + -
4 6 12 14 16 2 1 3 5 7 9 11 RS485 12 14 16 2 1 3 5 7 9 11 4 6 8 10 12 14 16 2 1 3 5 7 9 11
U1 U2 U3 N S1 S2 S1 S2 S1 S2 U1 U2 U3 N S1 S2 S1 S2 S1 S2 T1/2 U1 U2 U3 N S1 S2 S1 S2 S1 S2
L1 L2 L3
COUNTIS E40 L1 L2 L3 COUNTIS E43/E44/E45/E46 L1 L2 L3 COUNTIS E41/E42
%TRDR
F&
BK@RR""
References
COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS
E40 E41 E42 E43 E44 E45 E46
Type Reference Reference Reference Reference Reference Reference Reference
Via CT 4850 3008
Via CT - Dual tariff 4850 3009
5H@"3#T@KS@QHEE,(# 4850 3015
5H@"3VHSG12,.#!42BNLLTMHB@SHNM(1) 4850 3017
5H@"3VHSG12,.#!42BNLLTMHB@SHNM,(#(1) 4850 3014
5H@"3VHSG,!42BNLLTMHB@SHNM(1) 4850 3027
5H@"3VHSG,!42BNLLTMHB@SHNM,(#(1) 4850 3028
,@M@FDLDMSRNESV@QDENQ".4-3(2 See page 464
S@QHEERSGQNTFG12BNLLTMHB@SHNM
> Industry.
> Infrastructure.
> Data centres.
count_196_b_1_cat
Conformity to standards
count_197_b_1_x_cat
Common characteristics
COUNTIS E50 > IEC 62053-23
q Measurement accuracy: 0.5%.
class 2
q Large backlit LCD display.
> IEC 62053-22
q Direct access to multi-measurement
class 0.5S
and metering values. CO
Electrical characteristics
count_196x_b_2_cat
Current measurement
Type three-phase on CT/5A up to 6000 A
Input consumption
5 1 2 3 4 5
Startup current (Ist) 40 mA
Minimum current (Imin) 50 mA(1) Case
Transition current (Itr) 250 mA(2)
Reference current (Iref) 5 A(3)
92 +- 0.0
0.8
Permanent overload (Imax) 6A
Intermittent overload 50 A for 1 s
Voltage measurement
Range of measurement 86 520 VAC
Input consumption < 0.1 VA
Permanent overload 800 VAC
count_194_c_1_x_cat
Energy accuracy
Reactive (according to IEC 62053-23) Class 2 CO
U
96 NT
IS
Power supply
Self-supplied no
20
Auxiliary power supply Us 110 400 VAC / 125 350 VDC +/-10 % 60
Frequency 45 65 Hz
96
Output (pulsed)
Number 1
Type 100 VDC - 0.5 A - 10 VA Type Panel mounting
Max. number of operations 8 Dimensions W x H x D 96 x 96 x 80 mm
Operating conditions Case degree of protection IP30
Operating temperature -10 55 C Front degree of protection IP52
Storage temperature -20 85 C Display type backlit LCD display
Relative humidity 95 % Voltage and current connection cross-section 0.5 2.5 mm
(1) I(min)
(tr Current connection cross-section 1.5 6 mm
(2) The accuracy class is guaranteed between Itr and Imax. Weight 370 g
(3) I(ref) = I(b)A@RDBTQQDMS ((tr) for direct connection COUNTIS.
Connection
Recommendation: - When disconnecting the COUNTIS, the secondary of each current transformer
- For IT earthing systems, it is recommended that the CT secondary is not must be short-circuited. This operation can be carried out automatically by a
connected to earth. SOCOMEC PTI, an accessory which is included in this catalogue.
Please consult us.
Low voltage balanced network Low voltage unbalanced network
3/4 wires with 1 CT 3/4 wires with 3 CTs 3 wires with 2 CTs
N P1 L1
N
P1 P1 S1 P1
L1 L1 L2
S1 S2 S1 S2 S1 S2
L2 L2 L3
L3 P1 L3
S1 S2
1 1 1 1 1 1
1 1 1
diris_392_d_1_x_cat
diris_395_d_1_x_cat
diris_397_d_1_x_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
Use of 1 CT reduces by 0.5% the accuracy of the phases, Use of 2 CT reduces by 0.5% the accuracy of the phases,
the current of which is worked out by vector calculation. the current of which is worked out by vector calculation.
Additional information
Communication via RS485 link AC & DC auxiliary power supply
110 / 400 VAC (IEC)
120 / 350 VDC (IEC)
1 1
LIYCY-CY
diris_400_h_1_x_cat
diris_398_c_1_x_cat
0V - + A U X
ON
RS485 1. Fuses 0.5 A gG / 0.5 A class CC.
Strong points
COUNTIS E63
> Compact.
> Advanced multi-
measurement functions.
Function Principle diagram > Detection of connection errors.
The COUNTIS E63 is a modular active
electrical energy meter which provides
Conformity to standards
metering for three single-phase loads, with
direct connection of up to 100 A. It directly
> IEC 62053-21
displays the total and partial energy and
class 1
power (kWh and kW) consumed by each
single-phase load. > IEC 62053-31
> IEC 62053-11
Management software
count_205_a_1_x_cat
CO
UN
TIS
E 63
COUNTIS E63 > To get the most effective
use from your Socomec
measurement and metering
devices, we offer a range of
dedicated software tools.
See page 464.
432.
Advantages
Compact Detection of connection errors
Due to the integration of three single-phase The product is protected against phase/
meters in the same case (7 modules wide), neutral inversion and detects wiring errors. This
SGD".4-3(2$OQNUHCDRRHFMHEHB@MS simplifies the installation and commissioning,
space-saving. thereby reducing associated costs, and
ensures that the device operates correctly.
Advanced multi-measurement functions
Advanced multi-measurement functions are
available via RS485 MODBUS communication:
q Instantaneous currents: I1, I2, I3
q Instantaneous voltages: U1, U2, U3
q Instantaneous power: 3P, 3S
q Instantaneous power factors: 3PF
q Load curves for each of the 3 phases:
Viewing of average positive active power
consumption over a programmable period.
Front panel
1. Backlit LCD display
2. Navigation key
3. Reset key
,DSQNKNFHB@K+$#
count_201x_a_1_cat
2
3
4
$KDBSQHB@KBG@Q@BSDQHRSHBR
Current measurement Power supply
Type 3 x single-phase - direct 100 A Self-supplied yes
Input consumption 0.5 VA max. per phase Frequency 'Y
Startup current (Ist) 80 mA Operating conditions
Minimum current (Imin) 0.5 A Operating temperature -10 to 55 C
Transition current (Itr) 2A Storage temperature -20 to 70 C
Reference current (Iref) 20 A Relative humidity
Permanent overload (Imax) 100 A Communication
Intermittent overload 3000 A max for 10 ms Link RS485
Voltage measurement Type 2 3 half duplex wires
Range of measurement 230 ... 400 V +/- 20 % Protocol MODBUS RTU
Consumption on inrush (VA) 2 MODBUS speed 4800 38400 bauds
Permanent overload 280 V phase-neutral / 480 V phase-phase
Energy accuracy
BSHUD@BBNQCHMFSN($" Class 1
Case
62.5 Type modular
126 45 Number of modules 7
Dimensions W x H x D WW
LL
Case degree of protection IP20
Front degree of protection IP51
count_203_a_1_x_cat
COUNTIS E60
Error Partial
Display type backlit LCD display
90
45
C=2Wh / imp
Flexible cable cross-section 2.5 to 35 mm2
3 x phases 100A
Weight F
Connection
N
L1 L1
L2 L2
L3 L3
BNTMS>>A>>&!>B@S
+ - 0
2 15 17 13 1 3 5 7 9 11
N RS485 L - 1 - L L - 2 - L L - 3 - L
COUNTIS E63
References
COUNTIS E63
Type Reference
3 x single phase - 100 A direct with RS485 MODBUS communication 4850 3016
Strong points
kWh
PC
VERTELIS
Software
Advantages
Up to 7 multi-utility meters and RS485 MODBUS communication
2 analogue sensors q Centralisation and transmission of pulse and
q 7 logical inputs + 2 analogue inputs. analogue data to a supervision station.
q Total, partial and programmable metering q Remote configuration of COUNTIS ECi
(day, week, month, year). device.
Load curves Improved customisation
Load curves are available for each of the 7 q Selection of the measuring unit:
logical inputs. J6GL3, liters.
A history of average values are available for q Selection of the currency unit: , K, , $.
the 2 analogue inputs (ECi3). Values can be displayed in the unit of your
choice and energy costs can be directly
calculated.
Tolerance 10 %
Frequency 45 / 65 Hz
2 Consumption 5 VA
Insulation voltage 3.5 kV
3 Communication
Link RS485
Type 2 3 half duplex wires
Protocol MODBUS RTU
1 4
MODBUS speed 9600 38400 bauds
Inputs
Number 7
Case Control voltage (integrated) 1030 VDC
Minimum signal width 10 ms
73 67 Maximum signal width 2s
44 Minimum duration between 2 pulses 30 ms
Edge triggering rising
Analogue inputs (ECi3)
Number 2
Current 25 mA
Accuracy 0.5 %
count_208_a_1_x_cat
45
Consumption 0.1 VA
Operating conditions
Operating temperature -10 +55 C
Storage temperature -20 +70 C
Relative humidity 95 %
Type modular
Number of modules 4
Dimensions W x H x D 73 x 90 x 67 mm
Case degree of protection IP20
Front degree of protection IP51
Display type backlit LCD display
Terminal blocks type fixed
Rigid cable cross-section 1 10 mm2
Flexible cable cross-section 0.5 6 mm2
Weight 215 g
Connection
Us 31 : logical input n1. 13-15-17 : RS485 link.
32 : logical input n2.
1 2 3 4 5 6 7 33 : logical input n3. 5-6 : Analogue input n1.
1 1 34 : logical input n4. 7-8 : Analogue input n2.
R = 120 35 : logical input n5. 9-10 : output.
count_209_a_1_x_cat
References
COUNTIS ECi2 COUNTIS ECi3
Auxiliary power supply Us Reference Reference
230 / 400 VAC 4853 0000
230 / 400 VAC + 2 analogue inputs 4853 0001
> Industry.
> Infrastructures.
> Data centres.
diris_791_c_1_cat
DIRIS A10 Strong points
Function Principle diagram > Easy to use.
The DIRIS A10 is a modular multifunction > Integrated temperature
meter for measuring electrical values in low sensor.
voltage networks. > Detects wiring errors.
It allows all electrical parameters to be > &RPSOLDQWZLWK,(&}
displayed and utilised for communication and/
or output functions.
Front panel
power factor.
2 5. Direct access key for energies.
3 6. Pushbutton for hour meter, temperature and programming menu access.
4 7. Metrological LED.
5
6
7
Case
64
72 44
Type modular
Number of modules 4
Dimensions W x H x D 72 x 90 x 64 mm
DIRIS A 10 Case degree of protection IP 30
diris_809_a_1_x_cat
I TEST
Front degree of protection IP 52
V F
Display type backlit LCD display
45
90
P PF
E OK
Voltage and current connection cross-
C PROG 4 mm2
section
C=0,1Wh/imp
Electrical characteristics
Current measurement on high-impedance inputs (TRMS) Energy accuracy
Via CT primary 9 999 A Active (according to IEC 62053-22) Class 0.5 S
Via CT secondary 5A Reactive (according to IEC 62053-23) Class 2
Measurement range 0 11 kA Auxiliary power supply
Input consumption 0.6 VA Alternating voltage 110 277 VAC
Measurement updating period 1s AC tolerance 15 %
Accuracy 0.2 % Frequency 50 / 60 Hz
Permanent overload 6A Consumption < 3 VA
Intermittent overload 10 In for 1 s Digital output (pulses or on/off)
Voltage measurements (TRMS) Number 1
Direct measurement between phases 50 500 VAC Type 20 / 30 VDC - 0.5 A - 10 VA
Direct measurement between phase and neutral 28 289 VAC Max. number of operations 8
Input consumption
5 Input (tariff)
Measurement updating period 1s Number 1
Accuracy 0.2 % Type 0 VAC: T1 / 200-277 VAC: T2
Permanent overload 800 VAC Communication
Power measurement Link RS485
Measurement updating period 1s Type 2 3 half duplex wires
Accuracy 0.5 % Protocol MODBUS RTU
Power factor measurement MODBUS speed 2400 38400 bauds
Measurement updating period 1s Operating conditions
Accuracy 0.5 % Operating temperature - 10 + 55 C
Frequency measurement Storage temperature - 20 + 70 C
Measurement range 45 65 Hz Relative humidity 85 %
Measurement updating period 1s
Accuracy 0.1 %
Connection
Recommendation:
- For IT earthing systems, it is recommended that the CT secondary is not connected to earth.
- When disconnecting the DIRIS, the secondary of each current transformer must be short-circuited. This operation can be carried out automatically by
a SOCOMEC PTI, an accessory which is included in this catalogue. Please consult us.
- It is recommended that the earthing point for the DIRIS A10 and the current transformer secondaries are not earthed at the same time.
/RZYROWDJHEDODQFHGQHWZRUN
3/4 wires with 1 CT 6LQJOHSKDVH 7ZRSKDVH
N P1 P1
P1 L1 L1
L1 S1 S2 S1 S2
S1 S2 N L2
L2
L3
1 1 1 1 1 1
diris_810_a_1_gb_cat
diris_811_a_1_gb_cat
diris_812_a_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC.
/RZYROWDJHXQEDODQFHGQHWZRUN
N P1 L1 P1 L1
P1 L1 S1 S2 L2 S1 P1 L2
S1 S2 L2 P1 L3 S1 S2 L3
P1 L3 S1 S2
S1 S2
1 1 1
diris_813_a_1_gb_cat
diris_814_a_1_gb_cat
diris_815_a_1_gb_cat
1 1 1
1 1 1
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
1. Fuses 0.5 A gG / 0.5 A class CC. Use of 2 CTs reduces by 0.5% the accuracy of the Use of 2 CTs reduces by 0.5% the accuracy of the
phases, the current of which is worked out by vector phases, the current of which is worked out by vector
calculation. calculation.
1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC.
Additional information
&RPPXQLFDWLRQYLD56OLQN AC auxiliary power supply
1 1
LIYCY-CY
diris_821_d_1_x_cat
diris_820_a_1_x_cat
0V - + 20 22
AUX
RS485
Terminals
diris_816_a_1_x_cat
12 14 16 2 20 22 1 3 5 7 9 11 18
V1 V2 V3 VN A U X S1 S2 S1 S2 S1 S2
I1 I2 I3
DIRIS A10
AUX: auxiliary power supply Us. 66 current inputs.
999 91 voltage inputs.
diris_819_b_1_x_cat
diris_816_a_1_x_cat
diris_818_a_1_x_cat
1 3 15 17 4 6 8 10
0V + - OUT 1 IN 1
RS485
References
Basic device DIRIS A10
Description Reference
DIRIS A10 (available in light grey on request) 4825 0010
DIRIS A10 with RS485 MODBUS communication (available in light grey on request) 4825 0011
Description of accessories To be ordered in multiples of Reference
Fuse disconnect switches for the protection of voltage inputs (type RM) 3 poles 4 5601 0018
Fuse disconnect switches for the protection of the auxiliary supply (type RM) 1 pole + neutral 6 5601 0017
Fuses type gG 10x38 0.5 A 10 6012 0000
Current transformer range 1 See page 488
Management software for DIRIS See page 464
diris_896_a
Strong points
Functions
Multi-measurement Metering Events
q Currents q Active energy: +/- kWh Alarms on all electrical values
- instantaneous: I1, I2, I3, In q Reactive energy: +/- kvarh Communications
- maximum average: I1, I2, I3, In Harmonic analysis Digital RS485 (MODBUS)
q Voltages & frequency q Total harmonic distortion (level 31) Input
- instantaneous: U1, U2, U3, U12, U23, U31, F - Currents: thd I1, thd I2, thd I3, thd ln q Pulse metering
q Power - Phase-to-neutral voltage: thd U1, thd U2, thd q Remote device status
- instantaneous: 3P, YP, 3Q, YQ, 3S, YS U3, (4 wire networks)
Output
- maximum average: YP, YQ, YS - Phase-to-phase voltage: thd U12, thd U23,
q Remote command of device
q Power factors thd U31, (3 wire networks)
q Alarm report
- instantaneous: 3PF, YPF
q Pulse report
Front panel
1 2 3 4 5
Case
68 +- 0.0
0.7
PR
E 49,4
OG
72
Accessories
Current transformers
(see page 488)
trafo_077_b_2_cat
trafo_024_a_2_cat
Electrical characteristics
Current measurement (TRMS) Energy accuracy
Via CT primary 9 999 A Active (according to IEC 62053-21) at 50 Hz Class 1
Via CT secondary 1 or 5 A Active (according to IEC 62053-21) at 60 Hz Class 2
Measurement range 0 11 kA Reactive (according to IEC 62053-23) Class 2
Input consumption 0.6 VA Operating conditions
Measurement updating period 1s Operating temperature - 10 + 55 C
Accuracy at 50 Hz 0.5 %
Storage temperature - 20 + 85 C
Accuracy at 60 Hz 1%
Permanent overload 6A Relative humidity 95 %
Intermittent overload 10 In for 1 s Auxiliary power supply
Voltage measurements (TRMS) Alternating voltage 220 277 VAC
Direct measurement between phases 69 690 VAC AC tolerance 15 %
Direct measurement between phase and neutral 40 400 VAC Frequency 50 / 60 Hz
VT primary 400 000 VAC Consumption 3 VA
VT secondary 60, 100, 110, 173, 190 VAC Digital pulse and control input
Input consumption
5 Number 1
Measurement updating period 1s Type optocoupler 8 to 30 VDC
Accuracy at 50 Hz 0.5 % Minimum signal width 10 ms
Accuracy at 60 Hz 1% Minimum duration between 2 pulses 18 ms
Permanent overload 800 VAC Communication
Power measurement Link RS485
Measurement updating period 1s Type 2 3 half duplex wires
Accuracy at 50 Hz 1% Protocol MODBUS RTU
Accuracy at 60 Hz 2% MODBUS speed 1200 38400 bauds
Power factor measurement Pulse, alarm and control output
Measurement updating period 1s Number 1
Accuracy at 50 Hz 0.5 % Power supply 8 to 30 VDC
Accuracy at 60 Hz 1% Minimum signal width 10 ms
Frequency measurement Minimum duration between 2 pulses 18 ms
Measurement range 45 65 Hz Type of optocoupler IEC 62053-31 Class A (5 ... 30 VDC)
Measurement updating period 1s 100 Wh,1 kWh, 10 kWh, 100 kWh,
Pulse weight
Accuracy 0.1 % J6GJ6G
Pulse length LRLRLRvLR
Terminals
diris_889_b_1_x_cat
V1 V2 V3 VN A U X S1 S2 S1 S2 S1 S2
66current inputs.
I1 I2 I3
diris_891_c_1_x_cat
+ - NC - + - +
OUT IN
RS485
Connection
Recommendation:
- For IT earthing systems, it is recommended that the CT secondary is not connected to earth.
- When disconnecting the DIRIS, the secondary of each current transformer must be short-circuited.
440.
This operation can be carried out automatically by a SOCOMEC PTI, an accessory which is included in this catalogue. Please consult us.
1 1 1
diris_392_d_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3
P1 L1 P1 L1
N S1
P1 S1 S2 P1
L1 L2 L2
S1 S2 P1 S1 S2
L2 L3 L3
P1 L3 S1 S2
S1 S2
1 1 1 1 1 1
1 1 1
diris_395_d_1_gb_cat
diris_397_d_1_gb_cat
diris_396_d_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
1. Fuses 0.5 A gG / 0.5 A class CC. Use of 2 CTs reduces by 0.5% the accuracy of the phases, Use of 2 CTs reduces by 0.5% the accuracy of the phases,
the current of which is worked out by vector calculation. the current of which is worked out by vector calculation.
1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC.
Additional information
&RPPXQLFDWLRQYLD56OLQN AC auxiliary power supply
1 1
LIYCY-CY
diris_893_a_1_gb_cat
diris_892_a_1_x_cat
+ - NC A U X
RS485
1. Fuses 0.5 A gG / 0.5 A class CC.
References
Basic device DIRIS A17
Auxiliary power supply Us Reference
220 ... 277 VAC with pulse output 4825 0101
220 ... 277 VAC with RS485 MODBUS communication 4825 0102
220 ... 277 VAC with RS485 MODBUS communication 4825 0103
Accessories
Description of accessories To be ordered in multiples of Reference
Fuse disconnect switches for the protection of voltage inputs (type RM) 3 poles 4 5601 0018
Fuse disconnect switches for the protection of the auxiliary supply (type RM) 1 pole + neutral 6 5601 0017
Fuses type gG 10x38 0.5 A 10 6012 0000
Current transformer range 1 See page 488
Management software for DIRIS See page 464
> Industry.
> Infrastructure.
> Data centres.
diris_750_a_1_cat
Functions
Front panel
1 2 3 4 5
Case
92 +- 0.0
0.8
96 DIR
IS
A2 + 0.8 Voltage and other connection cross-section 0.2 2.5 mm2
0
92 - 0.0
Current connection cross-section 0.5 6 mm2
I
Weight 400 g
5/TE
ST V
4
F
P
PF
20
OK
PR
E 60
OG
96
Plug-in modules
DIRIS A20
1 Output
DIRIS_445_a_1_cat
Communication
DIRIS_447_a_1_cat
Accessories
Current transformers ,3SURWHFWLRQ Panel mounting kit
(see page 488) IRUD[PPFXWRXW
trafo_077_b_2_cat
DIRIS_720_a_2_cat
trafo_024_a_2_cat
DIRIS_718_b_1_cat
Electrical characteristics
Current measurement on high-impedance inputs (TRMS) Energy accuracy
Via CT primary 9 999 A Active (according to IEC 62053-22) Class 0.5 S
Via CT secondary 5A Reactive (according to IEC 62053-23) Class 2
Measurement range 0 11 kA Auxiliary power supply
Input consumption 0.6 VA Alternating voltage 110 400 VAC
Measurement updating period 1s AC tolerance 10 %
Accuracy 0.2 % Direct voltage 120 350 VDC
Permanent overload 6A DC tolerance 20 %
Intermittent overload 10 In for 1 s Frequency 50 / 60 Hz
Voltage measurements (TRMS) Consumption 10 VA
Direct measurement between phases 50 500 VAC Pulse or alarm output
Direct measurement between phase and neutral 28 289 VAC Number 1
Input consumption
5 Type 100 VDC - 0.5 A - 10 VA
Measurement updating period 1s Max. number of operations 8
Accuracy 0.2 % Communication
Permanent overload 800 VAC Link RS485
Power measurement Type 2 3 half duplex wires
Measurement updating period 1s Protocol MODBUS RTU
Accuracy 0.5 % MODBUS speed 1400 38400 bauds
Power factor measurement Operating conditions
Measurement updating period 1s Operating temperature - 10 + 55 C
Accuracy 0.5 % Storage temperature - 20 + 85 C
Frequency measurement Relative humidity 95 %
Measurement range 45 65 Hz
Measurement updating period 1s
Accuracy 0.1 %
Terminals
V1 V2 V3 VN A U X S1 S2 S1 S2 S1 S2
I1 I2 I3 AUX: auxiliary power supply Us.
V1, V2, V3 & VN: voltage inputs.
DIRIS A20
0V - + 1 1 8 19
0n OUT 1
RS485 R = 120
Connection
Recommendation:
- For IT earthing systems, it is recommended that the CT secondary is not connected to earth.
- When disconnecting the DIRIS, the secondary of each current transformer must be short-circuited. This operation can be carried out automatically by a SOCOMEC
PTI, an accessory which is included in this catalogue. Please consult us.
diris_394_d_1_x_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3
I1 I2 I3
Use of 1 CT reduces by 0.5% the accuracy of the phases, 1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC.
the current of which is worked out by vector calculation.
1. Fuses 0.5 A gG / 0.5 A class CC.
3/4 wires with 3 CTs 3 wires with 2 CTs 3 wires with 2 CTs
P1 L1 P1 L1
N
P1 S1 S2 L2 S1 S2 L2
L1
S1 S2
L2
P1 L3 P1 L3
P1 L3 S1 S2 S1 S2
S1 S2
diris_396_d_1_gb_cat
diris_397_d_1_gb_cat
diris_395_d_1_gb_cat
1 1 1 1 1 1
1 1 1
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
1. Fuses 0.5 A gG / 0.5 A class CC. Use of 2 CTs reduces by 0.5% the accuracy of the Use of 2 CTs reduces by 0.5% the accuracy of the
phases, the current of which is worked out by vector phases, the current of which is worked out by vector
calculation. calculation.
1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC.
Additional information
LIYCY-CY 1 1
diris_398_c_1_x_cat
diris_400_h_1_x_cat
0V - + A U X
ON
RS485
References
> Industry.
> Data centres.
> Infrastructures.
DIRIS A41
diris_581_f_1_gb_cat
user has access to all the measurements > Detects wiring errors.
required for successfully carrying out energy Ethernet
> Customisable.
efficiency projects and ensuring the electrical
> Webserver function.
distribution is monitored. DIRIS A40 DIRIS A40 DIRIS A40
Front panel
1. Backlit LCD display.
2. Direct access key for currents and test function.
3. Direct access key for voltages and frequency.
4. Direct access key for active, reactive, and apparent powers and power factor.
5. Direct access key for maximum and average current and power values.
6. Direct access key for harmonic values.
7. Direct access key for energies, hour meter and programming menu.
diris_744x_a_1_cat
1 2 3 4 5 6 7
Plug-in modules
Pulse outputs
diris_445_a_1_cat
&RPPXQLFDWLRQ02'%86
diris_447_a_1_cat
352),%86 DP communication
SUB-D9 link with PROFIBUS DP protocol (speed up to 12 Mbauds).
diris_773_a
diris_777_a_1_cat
Ethernet communication
q Ethernet connection with MODBUS TCP or MODBUS RTU over TCP protocol.
q Embedded Webserver function (1).
(WKHUQHWFRPPXQLFDWLRQZLWK5602'%86JDWHZD\
diris_776_a_1_cat
q Ethernet connection with MODBUS TCP or MODBUS RTU over TCP protocol.
q Connection of 1 to 247 RS485 MODBUS slaves.
q Embedded Webserver function (1).
Analogue outputs
DIRIS A41* A maximum of 2 modules may be connected, providing up to 4 analogue outputs.
diris_448_a_1_cat
LQSXWVRXWSXWV
A maximum of 3 modules may be connected, providing up to 6 inputs and 6 outputs.
diris_449_a_1_cat
3U, Ppred, Qpred, Spred, internal TC, TC 1, TC2, TC3 and hour meter,
- remote control,
- timed remote control.
- 2 inputs for pulse metering.
* with a factory fitted neutral CT module.
Memory
diris_682_a_1_cat
Temperature
Temperature indication:
- internal,
- external sensor PT 100 (TC 1), (1) See "Management software for DIRIS" p. 464.
- external sensor PT 100 (TC 2), (2) See "external sensor PT 100" p. 505.
Accessories
Current transformers ,3SURWHFWLRQ 3DQHOPRXQWLQJNLWIRUD[PPFXWRXW
(see page 488)
trafo_077_b_2_cat
trafo_024_a_2_cat
diris_718_b_1_cat
diris_720_a_2_cat
Terminals
DIRIS A40
66 current inputs
diris_569_a_1_x_cat
V1 V2 V3 VN A U X S1 S2 S1 S2 S1 S2
$8; auxiliary power supplies Us
I1 I2 I3
99991 voltage inputs
DIRIS A40
DIRIS A41
V1 V2 V3 VN A U X S1 S2 S1 S2 S1 S2 S1 S2
I1 I2 I3 IN $8; auxiliary power supplies Us
99991voltage inputs
DIRIS A41
Communication module Pulse output module Analogue output module
diris_571_a_1_x_cat
diris_572_a_1_x_cat
1 2 3 4
diris_573_a_1_x_cat
0V - + 1
5 6 7 8
0n + - + -
RS485 R = 120 0/4-20 mA 0/4-20 mA
OUT 1 OUT 2 OUT 1 OUT 2
DIRIS A40 / A41 DIRIS A40 / A41 DIRIS A40 / A41
RS485 link. pulse output n1. analogue output n1.
5 selectable internal resistance pulse output n2. analogue output n2.
for RS485 end of line termination.
diris_753_a_1_gb_cat
19 20 21 22 23 24 25 26
9 10 11 12 17 18
sensor 1 sensor 2
OUT 1 OUT 2 + -
diris_574_b_1_x_cat
A-Cd A-Cd IN
synchro 27 28 29 30
1 3 14 15 16 DIRIS A40 / A41 sensor 3
- + - + DIRIS A40/A41
IN 1 IN 2 synchronisation input. Sensor 1 Sensor 2 Sensor 3
DIRIS A40 / A41 red red red
relay output n1. red red red
relay output n2. white white white
opto input n1. white white white
opto input n2.
10 BASE T 10 BASE T 0V - + 1
100 BASE T 100 BASE T 0n
RS485
RJ45 RJ45 gateway R = 120
DIRIS A40/A41 DIRIS A40/A41
Electrical characteristics
Current measurement on insulated inputs (TRMS) 2 inputs / 2 outputs module: Outputs (alarms / control)
Via CT primary 9 999 A Number of relays 2(1)
Via CT secondary 1 or 5 A Type 250 VAC - 5 A - 1150 VA
Measurement range 0 11 kA 2 inputs / 2 outputs module: Phototransistor inputs
Input consumption
5 Number 2(1)
Measurement updating period 1s Power supply 10 30 VDC
Accuracy 0.2 % Minimum signal width 10 ms
Permanent overload 6A Minimum duration between 2 pulses 18 ms
Intermittent overload 10 In for 1 s Type phototransistors
Voltage measurements (TRMS) Pulse output module
Direct measurement between phases 50 700 VAC Number of relays 2
Direct measurement between phase and neutral 28 404 VAC Type 100 VDC - 0.5 A - 10 VA
VT primary 500 000 VAC Max. number of operations 8
VT secondary 60, 100, 110, 173, 190 VAC Analogue output module
Frequency 50 / 60 Hz Number of outputs 2(2)
Input consumption
5 Type insulated
Measurement updating period 1s Range 0 / 4 20 mA
Accuracy 0.2 % Load resistance
Permanent overload 800 VAC Maximum current 30 mA
Current-voltage product MODBUS communication module
Limitation for 1A CT 10 000 000 Link RS485
Limitation for 5A CT 10 000 000 Type 2 3 half duplex wires
Power measurement Protocol MODBUS RTU
Measurement updating period 1s MODBUS speed 4800 38400 bauds
Accuracy 0.5 % PROFIBUS-DP communication module
Power factor measurement Link SUB-D9
Measurement updating period 1s Protocol PROFIBUS DP
Accuracy 0.5 % PROFIBUS speed 9.8 kbauds 12 Mbauds
Frequency measurement Ethernet communication module
Measurement range 45 65 Hz Connection RJ45
Measurement updating period 1s Speed 10 base T / 100 base T
Accuracy 0.1 % Protocol MODBUS TCP or MODBUS RTU over TCP
Energy accuracy Temperature module (inputs)
Active (according to IEC 62053-22) Class 0.5 S Type PT100
Reactive (according to IEC 62053-23) Class 2 Connection 2, 3 or 4 wires
Auxiliary power supply Dynamic - 20 C ... 150 C
Alternating voltage 110 400 VAC Accuracy +/- 1 digit
AC tolerance 10 % Maximum length 300 cm
Direct voltage 120 350 VDC / 12 48 VDC Operating conditions
DC tolerance 20 % / - 6 + 20 % Operating temperature - 10 + 55 C
Frequency 50 / 60 Hz
Storage temperature - 20 + 85 C
Consumption 5
Relative humidity 95 %
(1) Max. 3 modules / DIRIS.
(2) Max. 2 modules / DIRIS.
Case
+ 0.8
92 - 0.0
DIR
96 IS
A4
0 92
+ 0.8
- 0.0
35
60
96
Connections
5HFRPPHQGDWLRQWhen disconnecting the DIRIS, the secondary of each current transformer must be short-circuited. This operation can be carried out
automatically by a SOCOMEC PTI, an accessory which is included in this catalogue. Please consult us.
In TNC neutral systems it is recommended to use the functional earth module.
1 1 1
diris_392_d_1_x_cat
1 1 1
diris_393_d_1_x_cat
diris_394_d_1_x_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
Use of 1 CT reduces by 0.5% the accuracy of the phases, 1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC.
the current of which is worked out by vector calculation.
1. Fuses 0.5 A gG / 0.5 A class CC.
diris_396_d_1_x_cat
diris_397_d_1_x_cat
1 1 1 1 1 1 1 1 1
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
1 1 1
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 S1 S2
I1 I2 I3 IN
1. Fuses 0.5 A gG / 0.5 A class CC.
Additional information
&RPPXQLFDWLRQYLD56OLQN Connection of voltage transformer for HV networks AC & DC auxiliary power supply
110 / 400 VAC (CEI)
L1 120 / 350 VDC (CEI)
L2
L3
1 1
LIYCY-CY
diris_400_h_1_gb_cat
diris_399_b_1_x_cat
diris_398_c_1_x_cat
A U X
0V - +
ON
V1 V2 V3 N
RS485
1. Fuses 0.5 A gG / 0.5 A class CC.
References
DIRIS A41
Basic device DIRIS A40 with CT on the
neutral
Auxiliary power supply Us Reference Reference
110 ... 400 VAC / 120 ... 350 VDC 4825 0201 4825 0202
12 ... 48 VDC 4825 1201 4825 1202
Options
Plug-in modules(1) Reference Reference
Pulse outputs 4825 0090 4825 0090
RS485 MODBUS communication 4825 0092 4825 0092
Analogue outputs 4825 0093 4825 0093
2 inputs / 2 outputs 4825 0094 4825 0094
Communication Sub D9 PROFIBUSDP(2) 4825 0205 4825 0205
Memory 4825 0097 4825 0097
Embedded Webserver function (2). 4825 0203 4825 0203
Ethernet communication + RS485 MODBUS gateway (Embedded Webserver function)(2) 4825 0204 4825 0204
Temperature inputs 4825 0206 4825 0206
(1) Ease of integration for additional functions (maximum 4 slots on A40 and 3 on A41).
(2) Dimension of the plug-in module: 2 slots.
Accessories
To be ordered To be ordered
Description of accessories Reference Reference
in multiples of in multiples of
IP65 protection 1 4825 0089 1 4825 0089
Panel mounting kit for a 144 x 96 mm cut-out 1 4825 0088 1 4825 0088
Fuse disconnect switches for the protection of voltage inputs (type RM) 3 poles 4 5601 0018 4 5601 0018
Fuse disconnect switches for the protection of the auxiliary supply (type RM)
6 5601 0017 6 5601 0017
1 pole + neutral
Fuse type gG 10x38 0.5 A 10 6012 0000 10 6012 0000
Current transformer range 1 See page 488 1 See page 488
Ferrite to be associated with communication modules 1 4899 0011 4899 0011
Temperature sensor PT100 - M6 screw type 1 4825 0208 1 4825 0208
Temperature sensor PT100 - M6 eyelet type 1 4825 0209 1 4825 0209
Management software for DIRIS See page 464
DIRIS A60
DI
RIS
> Industry.
A6
0
> Infrastructure.
Ethernet
> Data centres.
DIRIS A40 DIRIS A40 DIRIS A40
RS485
General
measurement
report
PC
CHQHR>>B>>FA>B@S
VERTELIS
software
solution
Curves for
current
DIRIS A60 per phase
Strong points
Function PLC
Front panel
!@BJKHS+"#CHROK@X
#HQDBS@BBDRRJDXENQBTQQDMSRSDLODQ@STQDR@MCSDRSETMBSHNM
#HQDBS@BBDRRJDXENQUNKS@FDR@MCEQDPTDMBX
#HQDBS@BBDRRJDXENQ@BSHUDQD@BSHUD@MC@OO@QDMSONVDQR@MCONVDQE@BSNQ
#HQDBS@BBDRRJDXENQL@WHLTL@MC@UDQ@FDBTQQDMSUNKS@FD@MCONVDQU@KTDR
#HQDBS@BBDRRJDXENQG@QLNMHBRU@KTDR
CHQHR>W>@>>B@S
#HQDBS@BBDRRJDXENQDMDQFHDRGNTQLDSDQ@MCOQNFQ@LLHMFLDMT
1 2 3 4 5 6 7
Pulse outputs
q BNMEHFTQ@AKDOTKRDNTSOTSRSXODVDHFGS@MCCTQ@SHNM
NMJ6GJU@QG@MCJ5 G
CHQHR>>@>>B@S
Communication MODBUS
q 12KHMJVHSG,.#!42 protocol (speed up to
A@TCR
DIRIS A60*
CHQHR>>@>>B@S
Ethernet communication
q $SGDQMDSBNMMDBSHNMVHSG,.#!423"/NQ
,.#!42134NUDQ3"/OQNSNBNK
q $LADCCDC6DARDQUDQETMBSHNM.
CHQHR>>@
Ethernet communication
CHQHR>>@>>B@S
ZLWK5602'%86JDWHZD\
q $SGDQMDSBNMMDBSHNMVHSG,.#!423"/NQ,.#!42134
* With integrated memory module. over TCP protocol.
q "NMMDBSHNMNESN12,.#!42RK@UDR
q $LADCCDC6DARDQUDQETMBSHNM.
Analogue outputs
CHQHR>>@>>B@S
q L@WHLTLNELNCTKDRL@XADBNMMDBSDCOQNUHCHMF
TOSN@M@KNFTDNTSOTSR
q /DQLNCTKDNTSOTSR@RRHFM@AKDSN
3I, In, 3V, 3U, F, YP, YQ, YS, Y/%+"(RXR5RXR4RXR
Ppred, Q pred, Spred, TC internal, TC 1, TC 2, TC3
@MCSN5#"ONVDQRTOOKX
LQSXWVRXWSXWV
q L@WHLTLNELNCTKDRL@XADBNMMDBSDCOQNUHCHMFTOSNHMOTSR
CHQHR>>@>>B@S
and 6 outputs.
q /DQLNCTKDNTSOTSR@RRHFM@AKDSN
LNMHSNQHMF((M54%YP, YQ, YS, Y/%+"3'#(3'#(M
THD 3V, THD 3U, Ppred, Qpred, Spred, TC internal, TC 1, TC2,
TC3 and hour meter,
- remote control,
- timed remote control,
q 2 inputs for pulse metering.
Temperature
CHQHR>>@>>B@S
3DLODQ@STQDHMCHB@SHNM
- Internal
$WSDQM@KRDMRNQ/33"
$WSDQM@KRDMRNQ/33"
$WSDQM@KRDMRNQ/33"
(1) See "Management softwares for DIRIS" p. 464.
(2) See "External sensor PT 100" p. 505.
BBDRRNQHDR
Current transformers Split-core current ,3SURWHFWLRQ Panel mounting kit
(see page 488) transformers for a 144 x 96 mm cut-out
SQ@EN>>@>>B@S
SQ@EN>>A>>B@S
#(1(2>>@>>B@S
#(1(2>>A>>B@S
Terminals
DIRIS A60
66 current inputs
#(1(2>>@>>W>B@S
V1 V2 V3 VN A U X S1 S2 S1 S2 S1 S2
AUX: auxiliary power supplies Us
I1 I2 I3 99991 voltage inputs
DIRIS A60
#(1(2>>@>>W>B@S
#(1(2>>A>>FA>B@S
0V - + 1 10 BASE T 10 BASE T 0V - + 1
0n
100 BASE T 100 BASE T 0n
RS485 R = 120 RS485
RJ45
RJ45 gateway R = 120
DIRIS A60 DIRIS A60
DIRIS A60
12KHMJ
5 RDKDBS@AKDHMSDQM@KQDRHRS@MBD 12F@SDV@XQDRHRSNQ
ENQ12DMCNEKHMDSDQLHM@SHNM
1RDKDBS@AKDHMSDQM@KQDRHRS@MBD
ENQ12DMCNEKHMDSDQLHM@SHNM
#(1(2>>@>>FA>B@S
1 2 3 4 19 20 21 22 23 24 25 26
9 10 11 12
sensor 1 sensor 2
OUT 1 OUT 2
#(1(2>>A>>W>B@S
A-Cd A-Cd
OUT 1 OUT 2 27 28 29 30
DIRIS A60 sensor 3
1 3 14 15 16
DIRIS A60
pulse output n1. - + - +
3 - 4 : pulse output n2. IN 1 IN 2
DIRIS A60
9 - 10 : relay output n1.
Analogue output module relay output n2.
13 - 14 : opto input n1.
#(1(2>>@>>W>B@S
Electrical characteristics
Current measurement on insulated inputs (TRMS) 2 inputs / 2 outputs module: Outputs (alarms / control)
Via CT primary -TLADQNEQDK@XR 2
Via CT secondary NQ Type 5 " 5
Measurement range vJ 2 inputs / 2 outputs module: Phototransistor inputs (pulse metering)
Input consumption
5 -TLADQ 2
Measurement updating period 1s Power supply v5#"
BBTQ@BX
Minimum signal width LR
Permanent overload ,HMHLTLCTQ@SHNMADSVDDMOTKRDR LR
Intermittent overload (n for 1 s Type phototransistors
Voltage measurements (TRMS) Pulse output module
#HQDBSLD@RTQDLDMSADSVDDMOG@RDR v5 " -TLADQNEQDK@XR 2
#HQDBSLD@RTQDLDMSADSVDDMOG@RD@MCMDTSQ@K v5 " Type 5#"
5
VT primary 5 " ,@W
MTLADQNENODQ@SHNMR
VT secondary 5 " Analogue output module
Frequency 'Y -TLADQNENTSOTSR 2
Input consumption
5 Type insulated
Measurement updating period 1s Range vL
BBTQ@BX
+N@CQDRHRS@MBD
Permanent overload 5 " Maximum current L
Current-voltage product MODBUS communication module
+HLHS@SHNMENQ "3 +HMJ 12
+HLHS@SHNMENQ "3 Type vG@KECTOKDWVHQDR
Power measurement Protocol ,.#!42134
Measurement updating period 1s ,.#!42 speed vA@TCR
BBTQ@BX
Ethernet communication module
Power factor measurement Connection 1)
Measurement updating period 1s Speed A@RD3A@RD3
BBTQ@BX
Protocol ,.#!423"/NQ,.#!42134NUDQ3"/
Frequency measurement Temperature inputs
Measurement range v'Y Type /3
Measurement updating period 1s Connection NQVHQDR
BBTQ@BX
Dynamic "
"
Energy accuracy BBTQ@BX +/- 1 digit
BSHUD@BBNQCHMFSN($" "K@RR
2 Maximum length BL
1D@BSHUD@BBNQCHMFSN($" Class 2 Operating conditions
Auxiliary power supply Operating temperature v
"
KSDQM@SHMFUNKS@FD v5 " Storage temperature v
"
"SNKDQ@MBD Relative humidity
Direct voltage v5#" (1) Max. 3 modules / DIRIS.
DC tolerance (2) Max. 2 modules / DIRIS.
Frequency 'Y
Consumption 5
Case
0
- 0.0
35
60
96
Connection
Low voltage balanced network for DIRIS A60
Recommendation:6GDMCHRBNMMDBSHMFSGD#(1(2SGDRDBNMC@QXNED@BGBTQQDMSSQ@MRENQLDQLTRSADRGNQSBHQBTHSDC
3GHRNODQ@SHNMB@MADB@QQHDCNTS
@TSNL@SHB@KKXAX@2.".,$"/3(VGHBGB@MADENTMCHMSGD2.".,$"B@S@KNFTDOKD@RDBNMRTKSTR
1 1 1 1 1 1
diris_392_d_1_x_cat
diris_393_d_1_x_cat
CHQHR>>C>>W>B@S
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
4RDNE"3QDCTBDRAX
SGD@BBTQ@BXNESGDOG@RDR 1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC.
SGDBTQQDMSNEVGHBGHRVNQJDCNTSAXUDBSNQB@KBTK@SHNM
1. Fuses 0.5 A gG / 0.5 A class CC.
diris_396_d_1_x_cat
CHQHR>>C>>W>B@S
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
CCHSHNM@KHMENQL@SHNM
&RPPXQLFDWLRQYLD56OLQN Connection of voltage transformer for HV networks AC & DC auxiliary power supply
L1
L2 110 / 400 VAC (IEC)
L3 120 / 350 VDC (IEC)
1 1
LIYCY-CY
CHQHR>>A>>W>B@S
CHQHR>>G>>W>B@S
CHQHR>>B>>W>B@S
A U X
0V - +
ON
V1 V2 V3 N
RS485
References
Basic device DIRIS A60
Auxiliary power supply Us Reference
5 "
5#" 4825 0207
Options
Plug-in-modules(1) Reference
Pulse outputs 4825 0090
12,.#!42 communication 4825 0092
M@KNFTDNTSOTSR 4825 0093
2 inputs / 2 outputs 4825 0094
$SGDQMDSBNLLTMHB@SHNMDLADCCDC$SGDQMDS6DARDQUDQ 4825 0203
$SGDQMDSBNLLTMHB@SHNM
12,.#!42F@SDV@XDLADCCDC$SGDQMDS6DARDQUDQ 4825 0204
Temperature inputs 4825 0206
(1) Easy integration of additional functions (maximum 3 slots per device).
(2) Dimension of the plug-in module: 2 slots.
Options
Description of accessories To be ordered in multiples of Reference
(/OQNSDBSHNM 1 4825 0089
/@MDKLNTMSHMFJHSENQ@WLLBTSNTS 1 4825 0088
%TRDCHRBNMMDBSRVHSBGDRENQSGDOQNSDBSHNMNEUNKS@FDHMOTSRSXOD1,ONKDR 5601 0018
%TRDCHRBNMMDBSRVHSBGDRENQSGDOQNSDBSHNMNESGD@TWHKH@QXRTOOKXSXOD1,ONKD
MDTSQ@K 6 5601 0017
%TRDSXODF&W
6012 0000
%DQQHSDSNAD@RRNBH@SDCVHSGBNLLTMHB@SHNMLNCTKDR 1 4899 0011
Current transformer range 1 See page 488
3DLODQ@STQDRDMRNQ/3,RBQDVSXOD 1 4825 0208
3DLODQ@STQDRDMRNQ/3,DXDKDSSXOD 1 4825 0209
Management softwares for DIRIS See page 464
> Industry.
> Infrastructure.
diris_876_a_1_cat
Strong points
> Compact.
DIRIS A80 > Patented pending.
Function /QHMBHOKDCH@FQ@L > Management softwares.
DIRIS A80HR@BNLOKDSDO@MDKLNTMSDC > &RPSOLDQWZLWK,(&}
LTKSHETMBSHNMLDSDQVGHBGHMBNQONQ@SDR
> Conformity to standard
RCM current monitoring (Residual Current
(1}
,NMHSNQHMFENQMDSVNQJRVHSG3-2@MC DIRIS A80 DIRIS A80
CHQHR>>A>>FA>B@S
TT neutral systems, and enhanced data DI
RIS
A8
0
DI
RIS
A8
0
RS-485
RTOOKHDR@KKSGDLD@RTQDLDMSRQDPTHQDC Main
> ,(&
meter panel
ENQDMDQFXDEEHBHDMBXOQNIDBSRVGHKDHSR FODVV6
PC
1",ETMBSHNMOQNUHCDROQDUDMS@SHUD VERTELIS
D@QSGKD@J@FDHMENQL@SHNMDRRDMSH@KHM software
solution
> ,(&
BQHSHB@K@OOKHB@SHNMRSN@UNHCHMRS@KK@SHNM Currents
per phase
FODVV
RGTSCNVMR
curve
> ,(&
PLC > ,(&
Advantages > (1
%QNMSO@MDK Accessories
&RUHEDODQFHWUDQVIRUPHU,&
!@BJKHS+"#CHROK@X
2DDO@FD 522)
#HQDBS@BBDRRJDXENQSGDBTQQDMSR1",ETMBSHNM
and alarm reset.
#HQDBS@BBDRRJDXENQUNKS@FDR@MCEQDPTDMBX
#HQDBS@BBDRRJDXENQ@BSHUDQD@BSHUD@MC@OO@QDMSONVDQR
@MCONVDQE@BSNQ
diris_876x_a_1_cat
SNQD>>@
#HQDBS@BBDRRJDXENQL@WHLTL@MC@UDQ@FDBTQQDMSUNKS@FD
@MCONVDQU@KTDR
#HQDBS@BBDRRJDXENQG@QLNMHBU@KTDR@MCSGDBNMMDBSHNM
and RCM test functions.
#HQDBS@BBDRRJDXENQDMDQFHDRGNTQLDSDQ
@MCOQNFQ@LLHMFLDMT
1 2 3 4 5 6 7
Plug-in modules
DIRIS A80
CHQHR>>@>>B@S
Communication MODBUS
q 12KHMJVHSG,.#!42OQNSNBNK
RODDCTOSNA@TCR
diris_777_a_1_cat
#(1(2>>@>>B@S
Ethernet communication
q $SGDQMDSBNMMDBSHNMVHSG,.#!423"/NQ,.#!42134NUDQ3"/
OQNSNBNK
q $LADCCDC6DARDQUDQETMBSHNM(1).
diris_776_a_1_cat
Terminals
DIRIS A80
66BTQQDMSHMOTSR
CHQHR>>A>>W>B@S
V1 V2 V3 VN A U X S1 S2 S1 S2 S1 S2 S1 S2
AUX: TWHKH@QXONVDQRTOOKX4s
I1 I2 I3 IN 99991UNKS@FDHMOTSR
DIRIS A80
RCM module RCM module Memory module
1 input / 1 output RXWSXWV
CHQHR>>B>>W>B@S
diris_871_a_1_x_cat
CHQHR>>@>>W>B@S
K L K L 33 34 37 38 K L K L 33 34 35 36 17 18
+ -
IN
IN IPE OUT IN IN IPE OUT1 OUT2
synchro
DIRIS A80 DIRIS A80 DIRIS A80
./,1residual current ./,1residual current
K-L / IPE : ground fault current K-L / IPE : ground fault current
33-34 :QDK@XNTSOTSR 33-34 : QDK@XNTSOTSM
NOSNHMOTSR 35-36 :QDK@XNTSOTSM
Ethernet module Ethernet module + RS485 MODBUS gateway RS485 MODBUS module
CHQHR>>B>>FA>B@S
CHQHR>>B>>W>B@S
CHQHR>>A>>W>B@S
10 BASE T 10 BASE T 0V - + 1 0V - + 1
12F@SDV@XQDRHRSNQ
12KHMJ
5 RDKDBS@AKDHMSDQM@KQDRHRS@MBDENQ12 5 selectable internal resistance
end of line termination. ENQ12DMCNEKHMDSDQLHM@SHNM
Connections
Additional information
Communication via RS485 link Connection of voltage transformer for HV networks AC & DC auxiliary power supply
L1 110 / 400 VAC (IEC)
L2 120 / 350 VDC (IEC)
L3
1 1
CHQHR>>G>>FA>B@S
LIYCY-CY
CHQHR>>A>>W>B@S
CHQHR>>B>>W>B@S
A U X
0V - +
V1 V2 V3 N
ON
RS485
1. Fuses 0.5 A gG / 0.5 A class CC.
1 1 1 1
CHQHR>>@>>FA>B@S
CHQHR>>@>>FA>B@S
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 S1 S2 K L K L V1 V2 V3 VN S1 S2 S1 S2 S1 S2 S1 S2 K L K L
I1 I2 I3 IN I1 I2 I3 IN
IN IPE IN IPE
1. Fuses 0.5 A gG / 0.5 A class CC. 1. Fuses 0.5 A gG / 0.5 A class CC.
Electrical characteristics
Current measurement on insulated inputs (TRMS) Auxiliary power supply
5H@"3OQHL@QX 9 999 A Alternating voltage v5 "
Via CT secondary NQ AC tolerance
Measurement range vJ Direct voltage v5#"
(MOTSBNMRTLOSHNM
5 DC tolerance
,D@RTQDLDMSTOC@SHMFODQHNC 1s %QDPTDMBX 'Y
Accuracy
"NMRTLOSHNM 5
Permanent overload 6A MODBUS communication module
Intermittent overload 10 In for 1 s +HMJ 12
Voltage measurements (TRMS) 3XOD vG@KECTOKDWVHQDR
#HQDBSLD@RTQDLDMSADSVDDMOG@RDR v5 " Protocol ,.#!42134
#HQDBSLD@RTQDLDMSADSVDDMOG@RD@MCMDTSQ@K v5 " ,.#!42RODDC vA@TCR
53OQHL@QX 5 " Ethernet Communication Module
VT secondary 5 " Connection 1)
%QDPTDMBX 'Y 2ODDC 10 base T / 100 base T
(MOTSBNMRTLOSHNM
5 Protocol ,.#!423"/NQ,.#!42134NUDQ3"/
,D@RTQDLDMSTOC@SHMFODQHNC 1s %@TKSBTQQDMSLNMHSNQHMFBG@Q@BSDQHRSHBR(M@MC(PE)
Accuracy
(MOTSR(M@MC(PE
Permanent overload 800 VAC
-TLADQNEHMOTSR
Current-voltage product
Dedicated core balance transformers Q@MFD("lSQ@MRENQLDQQ@SHN
+HLHS@SHNMENQ "3 10 000 000
+HLHS@SHNMENQ "3 10 000 000 ,D@RTQDLDMSNEE@TKSBTQQDMS(M(PE L v
Power measurement Accuracy
,D@RTQDLDMSTOC@SHMFODQHNC 1s K@QLR(M@MC(PE
Accuracy
Thresholds @CITRSLDMSCDODMCHMFNMSGDKN@CBTQQDMSR
Power factor measurement Time setting 0 to 10 s
,D@RTQDLDMSTOC@SHMFODQHNC 1s +NFFHMF values, dates, durations and curves
Accuracy
-TLADQNEDUDMSR max. 1000 events
Frequency measurement Optocoupler input
Measurement range v'Y -TLADQ RODBHEHBSNSGDQDEDQDMBD
,D@RTQDLDMSTOC@SHMFODQHNC 1s /NVDQRTOOKX v5#"
,D@RTQDLDMSTOC@SHMFODQHNC
,HMHLTLRHFM@KVHCSG 10 ms
Energy accuracy ,HMHLTLCTQ@SHNMADSVDDMOTKRDR LR
BSHUD@BBNQCHMFSN($" "K@RR
2 3XOD NOSNBNTOKDQ
1D@BSHUD@BBNQCHMFSN($" "K@RR
Alarm outputs
Operating conditions
-TLADQNEQDK@XR RODBHEHBSNSGDQDEDQDMBD
.ODQ@SHMFSDLODQ@STQD v
"
2SNQ@FDSDLODQ@STQD v
" 3XOD 5 "l
Relative humidity ,@W
-NENODQ@SHNMR 10
Case
DI
96 RIS
A8
0 92
+ 0.8
- 0.0
35
60
96
References
Accessories
Description of accessories To be ordered in multiples of Reference
(/OQNSDBSHNM 1 4825 0089
/@MDKLNTMSHMFJHSENQ@WLLBTSNTS 1 4825 0088
%TRDCHRBNMMDBSRVHSBGDRENQSGDOQNSDBSHNMNEUNKS@FDHMOTSRSXOD1,ONKDR 5601 0018
%TRDCHRBNMMDBSRVHSBGDRENQSGDOQNSDBSHNMNESGD@TWHKH@QXRTOOKXSXOD1,ONKD
MDTSQ@K 6 5601 0017
%TRDRSXODF&W
10 6012 0000
%DQQHSDSNAD@RRNBH@SDCVHSGBNLLTMHB@SHNMLNCTKDR 1 4899 0011
Current transformer range 1 2DDO@FD488
"NQDA@K@MBDSQ@MRENQLDQ("
Type Toroid diameter (mm) Reference
(" 4950 6015
(" 4950 6030
(" 4950 6050
(" 80 4950 6080
(" 4950 6120
(" 4950 6200
(" 4950 6300
,@M@FDLDMSRNESV@QDRENQ#(1(2 2DDO@FD 464
Compatible with:
& power quality
COUNTIS E
Function
To get the most effective use from your Socomec measurement and metering devices, we can
provide dedicated software tools:
Easy Config software Webserver function
The Easy Config software enables quick 3GD#(1(2 RNOSHNM@K$SGDQMDSLNCTKDR
and easy remote device configuration for integrate HTML pages, enabling the
".4-3(2$".4-3(2$"H@MC#(1(2 LDSDQR
Webserver function to be directly accessed
Configuration files can be copied from and sent through a standard web browser (Internet
to these devices, or they can be created without $WOKNQDQ%HQDENW
DKHLHM@SHMFSGDMDDCENQ
BNLLTMHB@SHNM@MCRDMS@S@K@SDQSHLD
RNESV@QDHMRS@KK@SHNM
Multiple devices can be configured from a single The Webserver function enables:
file which is especially useful for OEMs and panel - monitoring of electrical values, COUNTIS ECi
builders, saving time when having to program - viewing of energy consumption,
L@MXCDUHBDRVHSGSGDR@LDBNMEHFTQ@SHNM
- managing alarms,
Analysis software - configuration of the main parameters
On the basis of an event log and the of installation,
CHROK@XDCBTQUDRSGD M@KXRHRRNESV@QD@KKNVR - viewing and extracting load curves
the analysis and extraction of quality data, SGQNTFG@
"25EHKD
as well as fault current monitoring
1DRHCT@K"TQQDMS,NMHSNQHMF
Principle diagram
DIRIS A
RS485 Software
verte_885_a_1_gb_cat
Easy Cong
PC Software
Webserver
Software
Analysis
PLC
g
nfi
r
rve
sis
Co
se
aly
sy
b
We
An
Ea
".4-3(2$VHSG12BNLLTMHB@SHNM q q
COUNTIS ECi q q
#(1(2 @MC VHSG12BNLLTMHB@SHNM q q
#(1(2 VHSG12BNLLTMHB@SHNM q q
#(1(2 VHSG$SGDQMDSBNLLTMHB@SHNMLNCTKD q q
#(1(2 @MC VHSG12BNLLTMHB@SHNMLNCTKD q q q (1) Through DIRIS A fitted with an Ethernet communication
#(1(2 @MC VHSG$SGDQMDSBNLLTMHB@SHNMLNCTKD q q q module with RS485 gateway.
CHQHR>>@>>FA>B@S
M@KXRHRRNESV@QD
Improvement to the reliability of your electrical installation can be achieved with this software through the analysis of displayed event curves
FDMDQ@SDCEQNLSGDDUDMSKNF
3GHRRNESV@QDB@MADBNMMDBSDCSNSGD#(1(2TRHMFDHSGDQ@M12,.#!42NQ$SGDQMDSBNLLTMHB@SHNMLNCTKD
3GD M@KXRHRRNESV@QDB@MADCNVMKN@CDCEQNLSGD2.".,$"VDARHSDVVV
RNBNLDB
BNL
Event log
CHQHR>>@>>FA>B@S
Webserver function
The Webserver function comprises HTML pages embedded within the optional Ethernet
BNLLTMHB@SHNMLNCTKDNESGD#(1(2 LTKSHETMBSHNMLDSDQ
3GDRDO@FDRB@MAD@BBDRRDC
UH@@MHMSDQMDSAQNVRDQRHLOKXAXDMSDQHMFSGD#(1(2 R(/@CCQDRR
3GD6DARDQUDQNEEDQRSGD
following functions:
q ,NMHSNQHMFNEDKDBSQHB@KU@KTDR
CHQHR>>@>>B@S
q 5HDVHMFDMDQFXBNMRTLOSHNM
q ,@M@FDLDMSNE@K@QLR
q 1DLNSDBNMEHFTQ@SHNMNESGDL@HMO@Q@LDSDQRENQLDSDQRVHSGHM
q 5HDVHMF@MCDWSQ@BSHMFKN@CBTQUDRSGQNTFG@
"25EHKD
CHQHR>>@>>FA>B@S
CHQHR>>@>>FA>B@S
#HROK@XENQUHDVHMFHMRS@MS@MDNTR@MC@UDQ@FDDKDBSQHB@KU@KTDR
#HROK@XENQUHDVHMFHMRS@MS@MDNTR@MC@UDQ@FDONVDQLD@RTQDLDMSR
@MCDMDQFXBNMRTLOSHNM
CHQHR>>@>>FA>B@S
3GDK@SDRS@K@QLR@QDC@SD@MCSHLDQDFHRSDQDC
3GDCTQ@SHNM@MC
U@KTDENQD@BG@K@QLKNVKHLHSU@KTDGHFGKHLHSU@KTD@RVDKK@RSGD
QDK@SDCNTSOTS@K@QLMTLADQ@QD@KRNCHROK@XDC
#@S@B@MADDWSQ@BSDCHM
BRUENQL@S
> Industry.
> Infrastructure.
> Data centres.
refit_002_a_1_cat
refit_005_a_1_cat
refit_010_a_1_cat
COUNTIS E44R DIRIS A40R TC0 36 400 A
Conformity to standards
COUNTIS:
Advantages Principle diagram > IEC 62053-21
+LJKRYHUDOODFFXUDF\ > IEC 62053-22
Low voltage distribution panel
RETROFIT Packs
&RPELQDWLRQRI&2817,65(752),7PHWHUVDQG7&2VSOLWFRUHFXUUHQW
WUDQVIRUPHUV
+ Meter all the values of the electrical network or any other energy (via the pulse
refit_002_a_1_cat
refit_010_a_1_cat
concentrator COUNTIS ECi ) in order to:
q Optimise and share energy costs,
q Reinvoice the consumption to the user (MID versions).
&RPELQDWLRQRI',5,65(752),7PXOWLPHDVXUHPHQWPHWHUVDQG7&2VSOLW
FRUHFXUUHQWWUDQVIRUPHUV
Measure and monitor all the values of the electrical network, or any other energy
+
(via the pulse concentrator COUNTIS ECi), in order to:
q Analyse energy consumption and quality,
refit_005_a_1_cat
refit_010_a_1_cat
q Identify malfunctions,
q Improve the availability of the installation.
Meters
Function
The &2817,6([5RIWKH5(752),7SDFNis an active electrical The &2817,6(5SDFNoffers MODBUS RTU communication via
energy meter designed for three-phase networks. It is connected to the RS485 and includes 4 tariffs.
network through 3 TCO's up to 600 A. &2817,6(5and (5 are MID-certified (B + D module).
The &2817,6(5RIWKH5(752),7SDFN is a totalising meter The &2817,6([5SDFNincludes an active and reactive energy
allowing direct reading of the power consumed, using a pulse output. It meter (96 x 96 mm unit).
is a double tariff meter for dual tariff invoicing. Two partial meters with reset allow the energy to be metered over a
specific period.
5HIHUHQFHV
COUNTIS E42R COUNTIS E44R COUNTIS E50R COUNTIS E53R
RETROFIT Pack RETROFIT Pack RETROFIT Pack RETROFIT Pack
Kit CT Ratio Reference Reference Reference Reference
Energy meter kWh MID + 3 TCO 100 A / 1 A 4850 4915 4850 4916
Energy meter kWh MID + 3 TCO 250 A / 1 A 4850 4925 4850 4926
Energy meter kWh MID + 3 TCO 400 A /1 A 4850 4935 4850 4936
Energy meter kWh MID + 3 TCO 600 A / 1 A 4850 4945 4850 4946
Energy meter kWh + 3 TCO 100 A / 1 A 4850 4917 4850 4918
Energy meter kWh + 3 TCO 250 A / 1 A 4850 4927 4850 4928
Energy meter kWh + 3 TCO 400 A /1 A 4850 4937 4850 4938
Energy meter kWh + 3 TCO 600 A / 1 A 4850 4947 4850 4948
Technical characteristics(1)
COUNTIS E42R COUNTIS E44R COUNTIS E50R COUNTIS E53R
Current measurement
Type TC/1 A up to 600 A TC/1 A up to 600 A TC/1 A up to 600 A TC/1 A up to 600 A
Input consumption 0.2 VA per phase 0.2 VA per phase < 0.6 VA < 0.6 VA
Overload 24 A / 0.5 s 24 A / 0.5 s 10 In for 1 s 10 In for 1 s
Permanent overload 1.2 A 1.2 A 1.2 A 1.2 A
Minimum current measured 10 mA 10 mA 3 mA 3 mA
Voltage measurement
Range of measurement 230 400 V 15 % 230 400 V 15 % 28 520 VAC 28 520 VAC
Input consumption 2 VA 2 VA < 0.1 VA < 0.1 VA
Permanent overload 280 V 280 V 800 VAC 800 VAC
Energy accuracy
Active (according to EN 50470) Class C Class C
Active (according to IEC 62053-22) Class 0.5 S Class 0.5 S
Reactive (according to IEC 62053-23) Class 2 Class 2
(1) Features not mentioned are identical to those of COUNTIS E4x and E5x standard products.
Multi-measurement meters
Function
',5,6$5(752),7SDFNVinclude a multifunction meter and 3 TCO's The ',5,6$5 and ',5,6$5 packs include a 96 x 96 mm
TOSN
panel mount multifunction meter, dedicated to low voltage networks.
It ensures the user has access to all the measurements required for
The ',5,6$5SDFNincludes a modular format multifunction meter successfully carrying out energy efficiency project and ensuring the
for measuring electrical values in low voltage networks. It allows all electrical distribution is monitored. For more information, please see
electrical parameters to be displayed and utilised for communication the standard DIRIS A20 pages.
and/or output functions.For further details on functions see the The ',5,6$5 pack offers advanced features and a larger choice of
standard DIRIS A10 pages. options. Please see the standard DIRIS A40 pages for more information.
5HIHUHQFHV
A10R without COM A10R with COM A20R A40R
Kit CT Ratio Reference Reference Reference Reference
DIRIS A10R + 3 TCO 100 A / 1 A 4825 4911
DIRIS A10R + 3 TCO 250 A / 1 A 4825 4921
DIRIS A10R + 3 TCO 400 A /1 A 4825 4931
DIRIS A10R + 3 TCO 600 A / 1 A 4825 4941
DIRIS A10R with COM + 3 TCO 100 A / 1 A 4825 4912
DIRIS A10R with COM + 3 TCO 250 A / 1 A 4825 4922
DIRIS A10R with COM + 3 TCO 400 A /1 A 4825 4932
DIRIS A10R with COM + 3 TCO 600 A / 1 A 4825 4942
DIRIS A10R + 3 TCO 100 A / 1 A 4825 4913
DIRIS A20R + 3 TCO 250 A / 1 A 4825 4923
DIRIS A20R + 3 TCO 400 A /1 A 4825 4933
DIRIS A20R + 3 TCO 600 A / 1 A 4825 4943
DIRIS A40R + 3 TCO 100 A / 1 A 4825 4914
DIRIS A40R + 3 TCO 250 A / 1 A 4825 4924
DIRIS A40R + 3 TCO 400 A /1 A 4825 4934
DIRIS A40R + 3 TCO 600 A / 1 A 4825 4944
Technical characteristics(1)
DIRIS A10R +
DIRIS A10R communication DIRIS A20R DIRIS A40R
Current measurement on high-impedance inputs (TRMS)
Via CT primary 600 A 600 A 600 A 600 A
Via CT secondary 1A 1A 1A 1A
Input consumption 0.6 VA 0.6 VA 0.6 VA
5
Measurement updating period 1s 1s 1s 1s
Accuracy 0.2 % 0.2 % 0.2 % 0.2 %
Permanent overload 1.2 A 1.2 A 1.2 A 1.2 A
Intermittent overload 10 In for 1 s 10 In for 1 s 10 In for 1 s 10 In for 1 s
Voltage measurements (TRMS)
Direct measurement between phases 50 500 VAC 50 500 VAC 50 500 VAC 50 700 VAC
Direct measurement between phase and neutral 28 289 VAC 28 289 VAC 28 289 VAC 28 404 VAC
VT primary 500 000 VAC
VT secondary 60, 100, 110, 173, 190 VAC
Input consumption
5
5
5
5
Measurement updating period 1s 1s 1s 1s
Accuracy 0.2 % 0.2 % 0.2 % 0.2 %
Permanent overload 800 VAC 800 VAC 800 VAC 760 VAC
Power measurement
Measurement updating period 1s 1s 1s 1s
Accuracy 0.5 % 0.5 % 0.5 % 0.5 %
(1) Characteristics that are not listed are identical to those of the standard DIRIS A10, A20 and A40 range.
Technical characteristics
TCO 24 TCO 36
Reference Reference Reference Reference
TCO 182T 4910 182T 4925 182T 4940 182T 4960
H
refit_017_a_1_gb_cat
P
L
Services
Take advantage of the advice offered by an energy specialist
Socomec offers a full range of customised q Implementation
services for your energy efficiency requirements q Training
and can help you find the best solution: q Electrical facility audit
q Project engineering.
sydiv_069_a_1_gb_cat
For more details download our Service brochure available on our web site :
www.socomec.com or contact your SOCOMEC office.
Zoom
Think about it
&2817,6(&L
count_207_a_1_cat
9(57(/,66XSHUYLVLRQ
> Industry.
DIRIS_755_a_1_cat
DIRIS_754_a_1_cat
> Infrastructure.
> Health care buildings.
> Data centres.
DIRIS_762_a_1_gb_cat
DIRIS N
Function
DIRIS N300 / N600 are multifunction network To ensure these aims are achieved, the
analysers designed for in-depth analysis #(1(2-HMBKTCDRSGDENKKNVHMFETMBSHNMR Strong points
of electrical networks in order to improve q measurement of electrical values and
their availability and efficiency. They actively temperatures, > Easy to use.
contribute to procedures for optimising the q management of energy and allocation of > Customisable.
operation of your electrical networks. other utilities (water, gas),
They enable you to: > Powerful.
q monitoring of all parameters,
q improve the efficiency of the facility, > Accurate.
q control/command of apparatus,
q reduce production costs, q analysis of the network quality > Conformity to standard
q optimise operating costs, (waveform, EN 50160 report), (1}
q optimise maintenance costs, q communication.
&DMDQ@KBG@Q@BSDQHRSHBRNESGD#(1(2-@MC-
3GDU@RSL@INQHSXNESGDETMBSHNMRADKNV@QD@U@HK@AKD@RMTLDQHB@KU@KTDRHMRS@MS@UDQ@FDLHMHLTL@MCL@WHLTL
values), graphs (wave captures and 1/2 period RMS) and logs.
M Measurements: Monitoring:
DIRIS N...
Communication:
- Currents, voltages, frequency - Display of an alarm and status log. 12TRHMF,.#!42
(instant, average, minimum - Indication of the parameter !@RD3@MC!@RD3$SGDQMDS
@MCL@WHLTL
concerned, the status at time T, the ,.#!423"/
- Direct, inverse and homopolar duration and date/time of the start 42!ONQSRGNRSCDUHBD
voltages. and end of the event. .ODM" -HMSDQM@KATRENQ#(1(2.
5NKS@FDTMA@K@MBD
modules).
- Active, reactive, apparent
and predictive power. DIRIS N600:
- Power factor. Control/Command The user also has the following
- Fresnel diagram. (only with the DIRIS O): functions:
- Temperatures. - Controls and commands the - Flicker (Pst and Plt).
position of the remote devices. - EN 50160 report.
0 123
e Energy management:
- Active, reactive and apparent energy
- Programmes the logical functions to
create automatic processes.
5NKS@FDSQ@MRHDMSRR@LOKHMFR
5NKS@FD@MCBTQQDMSHMSDQG@QLNMHBR
meters.
- Impulse meters (up to 20 meters).
- Timestamped meters
(up to 8 meters).
Q
Network and event
quality analysis:
- Load curves. - Dips, surges and voltage cut-offs.
- Crest factor.
5NKS@FD@MCBTQQDMSG@QLNMHBR
- Mains signalling voltages.
A hub of innovation
The DIRIS N, developed using innovative technology, has enabled some functions to reach a new level.
diris_827_a_1_cat
This software reproduces the screens of the DIRIS D600 identically q Quality Parameters
on a PC. Any user can therefore access all the data to save time and q Diagnosis.
increase readability: q Configuration.
q Measurements
q Energies "NLLTMHB@SHNMADSVDDMSGD/"@MCSGD#(1(2-TMHSRHRUH@$SGDQMDS
q Events RHLTKS@MDNTRCHROK@XNERDUDQ@K#(1(2-HRONRRHAKD
Multi-display of Transformer_1
M instantaneous measurements 18/02/2009 10:18
V 18.39 kvar
Q 59.71 kvar FP
F 50.01 Hz
AVG STOP
Load curve displayed Total and partial consumption displayed per time slot
kW
600
P 690,0 kW
500
400
CHQHR>>@>>FA>B@S
diris_842_a_1_gb_cat
300
200
100
27/11/2012 10:18:05
0 Page 12/12
12 14 16 18 20 22 0 2 4 6 8 10 H
diris_786_b_1_gb_cat
Case
DIRIS N300/N600
287
150
CHQHR>>@>>W>B@S
DIRIS N 600
148
135
123
CHQHR>>@>>B@S
46
6.5 61
DIN-rail mounting
diris_794_a_1_cat
DIRIS D600
90
diris_796_a_1_cat
CHQHR>>@>>W>B@S
+ 0.8
92
- 0.0
151 33
84
DIRIS O
DIRIS O
146
135
123
diris_798_a_1_cat
CHQHR>>A>>W>B@S
diris_799_a_1_cat
7 44
72 58
.OSHNMR
DIRIS D 600: an ergonomic remote colour TFT graphic interface
CHQHR>>@>>B@S
2
I2 = 272.5 A 147.0
diris_782_b_1_gb_cat
I2 I1
V3 = 220.8 V 261.0
I3 = 230.0 A 243.0
Vn = 54.00 V 0.000
0 In = 9400 A 32.00 A single DIRIS D 600 interface can be used
FP1= 0,885
FP2= 0,791 to display information from several DIRIS N
FP3= 0,774
In P1= 16.20 kW through windows on the screen dedicated to
I3 P2= 18.90 kW
P3= 16.92 kW measurement, analysis of consumption and
20/02/2009 15:57:28
240 energy quality, along with their associated
STOP SAVE
events and curves.
diris_755_a_1_cat
q Acquire and apply the positions of breaker components, contactors, sensors, etc.
q Centralise pulses from water, gas and electricity meters.
q Apply information from analogue sensors (temperature, flow, humidity level, pressure, etc.).
q Actuate breaker components, perform load shedding actions upon alarms. The inputs/outputs can be activated via logic equations.
Characteristics
DIRIS N300/N600 DIRIS D600 DIRIS O DIRIS O: 2 analogue DIRIS O: 2 analogue
remote interface 4 inputs - 2 outputs inputs 0/420 mA outputs 0/420 mA
Auxiliary power supply
Alternating voltage v5 "
AC tolerance 10 %
Frequency 50 / 60 Hz
Direct voltage v5#" 5#"(1) 5#"(1) 5#"(1) 5#"(1)
DC tolerance 10 % 10 % 10 % 10 % 10 %
2.5 mm2 pull-out 2 point 2.5 mm2 pull-out 2 point 2.5 mm2 pull-out 2 point 2.5 mm2 pull-out 2 point 2.5 mm2 pull-out 2 point
Connection
terminal block terminal block terminal block terminal block terminal block
Mechanical
Consumption 10 W 1.5 W
6 2.5 W
Type modular modular modular modular
Number of modules 16 4 4 4
#HLDMRHNMR6W'W# WW
WW WW WW WW
Cut-out W
5HAQ@SHNMR IEC 60068-2-6 compliant IEC 60068-2-6 compliant IEC 60068-2-6 compliant IEC 60068-2-6 compliant IEC 60068-2-6 compliant
Protection degree IP40 (panel face), IP20 (unit) IP52 IP52 (panel face), IP20 (unit) IP40 (panel face), IP20 (unit) IP 40 (panel face), IP20 (unit)
Weight F 600 g 200 g 210 g 220 g
(1) Auxiliary supply or via DIRIS N300/N600 (limited to 15 W) or Power over Ethernet or Power over Can
DIRIS N300/N600 DIRIS D600 DIRIS O DIRIS O DIRIS O
remote interface 4 inputs - 2 outputs 2 analogue inputs 2 analogue outputs
0/420 mA 0/420 mA
Communication
Link RS485 ETHERNET ETHERNET !42./3(.- !42./3(.- !42./3(.-
Type G@KECTOKDWVHQDR G@KECTOKDWVHQDR
,.#!42 TCP or Proprietary in TCP Proprietary in CAN Proprietary in CAN
Protocol ,.#!42134 Proprietary in CAN mode
proprietary mode mode mode
,.#!42 speed 9.6 115.2 kbauds
Address 000 256
2.5 mm2 pull-out W1)ONHMS W1)ONHMS W1)ONHMS W1)ONHMS W1)ONHMS
Connection
ONHMSSDQLHM@KAKNBJ straight cable straight cable straight cable straight cable straight cable
Characteristics
Characteristics of the PMD (IEC 61557-12) Memory
Evaluation of the power supply quality (possible function) - Memory size ,!
PMD classification SD Environment
Temperature K55 ,@W
NODQ@SHMFSDLODQ@STQD -10 +55 C
Humidity + Altitude - ,@W
RSNQ@FDSDLODQ@STQD -25 70 C
.ODQ@SHMFODQENQL@MBDBK@RRNE@BSHUDONVDQNQ@BSHUD Humidity 0 75 % RH
0.2
energy (if possible function) Salt spray EN 60068-2-52
Startup duration 50 seconds Protection degree IEC 60259
Characteristics of the functions/ Sine vibrations IEC 60068-2-6
Evaluation of the power supply quality (IEC 61557-12) Dry heat test (operation and storage) IEC 60068-2-2
P (Total active power) - class 0,2 5 % In to 2 In Wet heat cyclic test ($"
Qv (reactive power) - class 1 5 % In to 2 In In-operation and storage cold test IEC 60068-2-1
Sv - class 0.2 5 % In to 2 In Product standards and certification
Ea - class 0.2 5 % In to 2 In Product standard IEC 61557-12 ed. 1
Erv - class 1 5 % In to 2 In Active energy metering ($"BK@RR
2
Eapv - class 0.2 5 % In to 2 In Reactive energy metering ($"BK@RR
f - class 0.02 Fnom 15 % Measurement standards and certification
I - class 0.1 0.1 In to 2 In Harmonics and interharmonics
In / Inc - class 0.1 0.1 In to 2 In IEC 61000-4-7
measurement method
4BK@RR
Flicker measurement method IEC 61000-4-15
PFv - class 0.5 PF = 0.5 lag. to 0.5 lead. Supply power quality measurement method ($"
Pst / Pit - class 5 (complies IEC 61000-4-15) 0 20 Characteristics of the voltage supplied by public
4CHOBK@RR
4nSN4n EN 50160
distribution networks
4RVKBK@RR
4nSN4n Communication standards and certification
4SQ vJ5 RS485 TIA-485A
4HMSBK@RR
v4n 32!!
4MA@BK@RR
($$ %
4MABK@RR
Ethernet
>2DBSHNM
4GBK@RR
>2DBSHNM
THDu - class 1 Protocol standards and certification
THD-Ru - class 1 RS485 ,.#!42
Ih - class 1 Ethernet ,.#!42
THDi - class 2 42! 42!
THD-Ri - class 1 CAN (2.
Msv - class 1 DIRIS D600 interface
Measurements Display TFT
Network type three-phase without neutral or with neutral Dimensions WOHWDKR
Number of power outlets NQ Dimension
W
LL
Measurement category 5B@S(((($" DIRIS O 4i2o-d (4 inputs/2 outputs): inputs
! DWBDOSENQSDLONQ@K@FFQDF@SHNM Number 4
Measurement method class
($" Type phototransistors
TRMS up to level 50 Power supply v5#"
10 240 Hz (at the nominal network Minimum current 1 mA
Measurement sampling frequency
frequency) ,@HMHMRTK@SHNMENQ5 "/G-MDSVNQJ
J5 "QLRLHMTSD
Transient sampling frequency 1 MHz that is 1 s Leakage path LL
Instantaneous measurements Number of switchings 108 operations
one second
refresh frequency
DIRIS O 4i2o-d (4 inputs/2 outputs): outputs
Plot refresh frequency 1 60 minutes
Number of operations 5
Event log refresh frequency 1 60 s
5 "5#"
Voltage inputs Power supply
5 6
Number of voltage inputs /G@RD
-DTSQ@K
$@QSG Number of relays 2
5 "OG@RD-DTSQ@K@MC5 Leakage path LL
Nominal voltage without TP
AC (phase/phase)
,@HMHMRTK@SHNMENQ5 "/G-MDSVNQJ
J5 "QLRLHMTSD
OQHL@QXL@WHLTL
DIRIS O 2i-a inputs (2 analogue inputs)
5NKS@FDSQ@MRENQLDQ J5 "2DBNMC@QX
5 " Number 2
Permanent overload 5 " Scale 0 / 4 20 mA
Frequency 45 65 Hz NEETKKRB@KDVGHBGHR
Accuracy
L
Insulation 5B@S(((
,@W
HLODC@MBDNEHMOTSR
Connection
LLOTKKNTSONHMSSDQLHM@KAKNBJ
,@HMHMRTK@SHNMENQ5 "/G-MDSVNQJ
J5 "QLRLHMTSD
Current inputs
Leakage path LL
Number of current inputs /G@RD
-DTSQ@K
DIRIS O 2o-a outputs (2 analogue outputs)
Nominal current without CT 5A
Number of outputs 2
Current transformers OQHL@QXL@W 2DBNMC@QXNQ Scale 0 / 4 20 mA
Input consumption
5 Load resistance
Permanent overload 20 A
NEETKKRB@KDVGHBGHR
Accuracy
Intermittent overload 20 In / 1s
L
Insulation main ,@WHLTLBTQQDMS 25 mA
Connection 6 mm2ONHMSEHWDCSDQLHM@KAKNBJ ,@HMHMRTK@SHNMENQ5 "/G-MDSVNQJ
J5 "QLRLHMTSD
USB Leakage path LL
'NRSKNVONVDQL L@W 1
Device 1
Terminals
DIRIS N300/N600
Lower terminal blocks
CHQHR>>A>>W>B@S
A U X V1 V2 V3 VN S1 S2 S1 S2 S1 S2 S1 S2
I1 I2 I3 IN
- + - + - + BUS MODULES 1
0V - + 10 BASE T 10 BASE T
pulse pulse synchronisation OPTIONS 0n 100 BASE T 100 BASE T
output output input R = 120 RS485
1 2 RJ45 RJ45 RJ45
termination resistances ETHERNET DISPLAY
DIRIS N300 / N600
DIRIS O
Upper terminal blocks (shared by all modules) DQDORJXHRXWSXWVbP$
diris_804_a_1_gb_cat
CHQHR>>@>>W>B@S
BUS MODULES BUS MODULES 1
- + + - + -
OPTIONS OPTIONS 0n 5 6 7 8
R = 120 AUX Out 1 Out 2
RJ45 RJ45
DIRIS O DIRIS O
CHQHR>>@>>W>B@S
+ - + - + - + - + - + - + - + -
13 14 15 16 17 18 19 20 9 10 11 12 1 2 4 4
In 1 In 2 In 3 In 4 Out 1 Out 2 In 1 In 2
DIRIS O DIRIS O
References
DIRIS N300/N600
Description Reference
#(1(2- 4826 0001
DIRIS N600 4826 0002
Optional DIRIS D600
Description Reference
DIRIS D600 (remote interface) 4826 0003
DIRIS O
Description Reference
#(1(2.HNCCHFHS@KHMOTSRCHFHS@KNTSOTSR 4826 0071
#(1(2.H@@M@KNFTDHMOTSR 4826 0072
#(1(2.N@@M@KNFTDNTSOTSR 4826 0073
Accessories
Description of accessories To be ordered in multiples of Reference
%TRDCHRBNMMDBSRVHSBGDRENQSGDOQNSDBSHNMNEUNKS@FDHMOTSRSXOD1,ONKDR 4 5601 0018
%TRDCHRBNMMDBSRVHSBGDRENQSGDOQNSDBSHNMNESGD@TWHKH@QXRTOOKXSXOD1,ONKD
MDTSQ@K 6 5601 0017
%TRDRSXODF&W
10 6012 0000
Current transformer range See page 488
> Industry.
> Building.
> Infrastructure.
> Local authority.
verte_027_a_1_cat
Strong points
verte_015_c_1_gb_cat
The first step in your Energy Efficiency
approach, VERTELIS VISION is a > Display of multi-utility load
solution composed of an industrial PC curves.
DIRIS A40
with embedded software (Vertelis box). Its
functionalities can be accessed from any
terminal (PC, pad, etc.) using a standard Services & Technical
Internet browser (Internet Explorer,
CO
UN
TIS
E Ci3 Assistance
Firefox, etc.). Its purpose is to collect data RS485
from DIRIS A, DIRIS N, COUNTIS E and COUNTIS ECi DIRIS A20 Ethernet
> Our expertise extends to a
COUNTIS ECi products for report analysis Software BO complete offer of customised
VERTELIS VISION
X services like installation audit,
and event log or alarm management
purposes.
Load curve commissioning, training,
Communication between the Vertelis
maintenance, and project
box and the devices is achieved either by
Single device engineering.
report
PC PC
means of the Ethernet network or a serial
RS485 port. General
measurement
report
Advantages
Turnkey solution Dedicated Industrial PC
For easy and quick implementation, The VERTELIS VISION software is pre-installed
our solution includes software in a dedicated industrial PC offering an
pre-configuration, commissioning enduring and reliable solution.
& maintenance. Display of multi-utility load curves
Report auto-configuration Key element to check that your contract tariff
Only devices, their hierarchy and energy tariffs is adapted to your consumption.
should be defined.
Functionalities
The VERTELIS VISION solution communicates The user can also have access to: All of this information is based on the
with all SOCOMEC products included in the q The logs of the selected electrical values measurements reported on a device or set of
installation. Thanks to manual or automatic over a defined time period. devices.
measurements, instantaneous or logged q The alarms (measurements, consumptions, For easy and quick implementation,
data reports are accessible using an internet status) the VERTELIS VISION solution includes
browser (Internet Explorer 9, Firefox). q Indications of malfuntions arising from the commissioning. Other services can be
It offers the easy supervision of the installation. provided by SOCOMEC, so do not hesitate to
instantaneous energy consumed by furnaces, q A manual or automatic report extraction. consult us.
manufacturing facilities, office buildings, etc.
General characteristics
The VERTELIS VISION solution makes it q Remotely set the date and time, the reset of Communication with SOCOMEC products:
possible to: indexes and the relay status. q Connection type: RS485, Ethernet.
q Supervise up to 50 measurement points. q Show the load or average curves (10, 15, q Supported protocols:
q Depending on the product characteristics, 20 or 30 min) and the related value charts Modbus RTU.
view energy indexes, electrical values for DIRIS A40/A60/A80 and Modbus TCP.
(U, I, FP, f, harmonics, etc.) and alarms. COUNTIS Ci / ECi.
Modbus RTU over TCP.
q View curves and statistics of the data logs q Set the automatic release of reports.
Languages
selected.
Multi-language software, includes the
following as standard: English, French,
Spanish, German, Italian, Dutch, Turkish.
Check it out
Supervision software
VERTELIS HYPERVIEW
Functionalities
General instantaneous reports Single device instantaneous reports
Measurements, indexes and inputs/outputs are presented in charts. Depending on the characteristics of the device selected, the following pages are
The data availability and content can vary depending on the selected device. available:
The user can decide to include each device in his reports. - measurements,
These pages are automatically refreshed over a defined period of time. - index,
They can also be extracted manually. - quality,
- inputs/outputs.
These pages are automatically updated over a defined period of time.Data can
be extracted in *.csv format.
Measurements
The 'Measures' page displays the following data:
verte_016_a_1_gb_cat
- currents,
- phase to neutral voltages,
- phase to phase voltage,
- frequency,
- power factors,
- active, reactive and apparent power
- impulse metering inputs (DIRIS A).
Measurements
verte_019_a_1_gb_cat
The page presenting the measurement general report shows the following data
for the selected device:
- currents,
- phase to neutral voltages,
- phase to phase voltage,
- frequency,
- active, reactive and apparent power per phase,
- power factors,
Index
- impulse metering inputs (DIRIS A).
Digital data viewing depends on the device characteristics:
If data is not available for a specific device or if the network setting is not - index of electrical values,
compatible, a dash (-) is displayed in the corresponding field. - values ol pulse meters,
- time index,
- index per tariff category.
Quality
verte_017_a_1_gb_cat
For the selected DIRIS A or N, viewing of harmonic curves and distortion rate
charts:
- the 3 currents and the neutral (depending on the network type),
- the phase to phase and phase to neutral voltages
(depending on the network type).
Index
verte_020_a_1_gb_cat
The 'Index' page shows the following data categories for all the DIRIS and
COUNTIS selected:
- partial electrical values,
- total electrical values,
- partial indexes,
- total indexes.
verte_018_a_1_gb_cat
Functions
Log file Index report
The VERTELIS VISION software has been designed to analyse the remotely They display a chart including the multi-utility indexes with the following
reported data stored over a selected period, that is: information:
- statistics and stored data, - start value,
- reports of indexes, - end value,
- load curves. - consumption difference in the corresponding utility unit,
- consumption difference in a unit common to all utilities,
Statistic reports and history logs - average cost over the period.
verte_028_a_1_gb_cat
- measures,
- quality,
- events.
verte_026_a_1_gb_cat
Statistics on Quality
The minimum, average and maximum values per day over the selected period for Alerts
analysed data are displayed. Data is displayed under curve and chart format.
Different types of notifications can be managed:
- alarms released by the DIRIS A,
- alarms about index differences,
- value alarms about the average, minimum and maximum
currents, voltage and power values reported.
E-mail alerts are sent to users by means of a message server.
Four web pages arealso available to view:
- alarms in progress,
verte_024_a_1_gb_cat
- alarms recorded,
- statistics on a specific alarm,
- alarm notifications.
Tools
Quality history logs They give access to the various tools needed for the correct operation of the
It is possible to view the graph and chart of stored measurements over the software as well as to a specific tool to create curves from the log file.
selected period. Example:
Curve for following up electricity consumption, external temperature and load curves
over a selected period.
verte_029_a_1_gb_cat
verte_025_a_1_gb_cat
inter_141_h_1_gb_cat
4OSNCDUHBDRB@MAD OR
connected to the interface programmable
logic controllers
CO
UN
TIS
E Ci3
inter_142_g_1_gb_cat
RS485 communication port. CO
UN
TIS
E Ci3
References
Description of accessories Reference
External USB / RS485 interface unit 4899 0110
LINE-B
devices can be exceeded.
RS422/RS48
REPEATER 5
One solution to this technical OR RS232 / RS485
PWR RDA
RDB BLA
BLB T+ T-
LINE-B
R+ R-
PWR RDA
RDB BLA
BLB T+ T-
LINE-B
R+ R-
DIRIS A40 COUNTIS ECi
Interface
restriction is to install an
RS422/RS485 RS422/RS485
REPEATER REPEATER
CO
UN
programmable TIS
E Ci3
logic controllers
interface which amplifies
LINE-A LINE-A
POWER POWER
R- R-
R+ T- R+ T-
T+ T+
inter_011_a
N N
L L
the signal over a further RS485 DIRIS A40 COUNTIS ECi RS485
LINE-A
OR
R-
R+ T- T+
POWE
R L@SA@TCRENQ others
1200 m
1200 m
CDUHBDR
N
L
systems
inter_143_h_1_gb_cat
References
Auxiliary power supply Us Frequency Reference
95 240 VAC / 110 250 VDC 50 Hz 4899 0120
4RHMFSGDSDKDOGNMDMDSVNQJ13",NCDL1212
Function
PC
On some sites it is not possible RS232 RS485
to connect all the devices using
a single cable. In some cases,
the distances may be such
OR Modem Modem
that the investment would be programmable
CO
UN
TIS
E Ci3
inter_144_g_1_gb_cat
@R@L@RSDQ12BNMMDBSDC
Modem
CHQDBSKXSN/"NQRK@UD12
connected to slave devices, via
MDSVNQJ
DIRIS A40 DIRIS A20
References
Auxiliary power supply Us Frequency Reference
22 240 VAC / 12 48 VDC 50 Hz 4899 0200
4RHMFSGD$SGDQMDSMDSVNQJ$SGDQMDS1212HMSDQE@BD
Function PC
Ethernet network
This interface enables RS485
programmable
These interfaces can be logic controllers
configured differently to suit
inter_057_a
CO
UN
TIS
E Ci3
inter_145_h_1_gb_cat
COUNTIS ECi DIRIS A40
RS485
CO
UN
TIS
E Ci3
DIRIS N The accessories listed in these pages represent a selection from our range.
COUNTIS
C
We can supply many other solutions upon request, such as SHDSL interfaces,
DIRIS E00 COUNTIS
C
A40 E40
EHAQDNOSHBR12&2,&/12@MCOQNSNBNKBNMUDQSDQHMSDQE@BDR
DIRIS
A10
M
DIRIS
A20
COUNTIS
C Need something integrating into your network?
UNTIS E30 Gateway
diris_581_d_1_gb_cat
ECi
CO
C
UNT
TIS
TCP/IP RS485
Our Services and Technical Assistance department will fully integrate all your
COUNTIS
C
E 50
E50 PLC
2.".,$"CDUHBDR
3GHRSD@LNEDWODQSRNEEDQR@BNLOKDSDQ@MFDNEBTRSNLHRDC
Gateway
solutions, including technical site audit and solution specification, commissioning,
TCP/IP RS485
training, maintenance, and project engineering.
B TM
M
C
S
/
> Industry.
> Service sector.
trafo_108_a_1_cat
Three-phase CT trafo_012_a_1_cat
Strong points
Bar-through CT
> An adapted accuracy class.
> A wide range of ratings and
dimensions.
trafo_077_b_1_cat
trafo_010_a_1_cat
Conformity to standards
Split-core CT Cable-through CT > IEC 61869-2
> IEC 61439-1
Function Advantages
SOCOMEC current transformers deliver to the An adapted accuracy class Other products
secondary a standard current proportional to In order to get the best of your DIRIS
the primary current and adapted to the rating multifunction meters and COUNTIS energy SOCOMEC also offer
of the associated device. They are equipped meters, we can provide current transformers customised solutions:
as standard with removable terminal covers with the following accuracy classes:
and double terminals allowing the secondary > 1 A secondary.
0.2s; 0.5; 1 or 3.
to be short-circuited without any risk. A wide range of ratings and dimensions > Double or triple primary ratio.
They are mounted using two screw-on metal Your measurement process can be optimised > Voltage transformer.
brackets or, in certain cases, by a clip-on DIN- whatever your needs in terms of ratings, space > Summation CTs.
rail fastener. The connections are made by requirements, conductor sizing or accuracy class.
screws or by fast-on terminals. A wide range of combinations are available in our
q Accuracy class: 0.2s - 0.5 or 1. standard range with specific versions available on
q Dielectric quality: 3 kV - 50 Hz - 1 min. request (other ratios, tropicalisation and specific
q Operating frequency: 50 - 60 Hz. frequency, class or burden).
q Permanent overload: 1.2 In. Quick and easy to mount
q Insulation class: E (120 C). Our current transformers are adapted to
any type of mounting: edgewise or flat
mounting, DIN-rail or back-plate mounting.
Implementation is easy and rapid.
trafo_014_b_1_cat
trafo_015_b_1_cat
Accessories
TRB 60 TRB 70 TRB 135
Description of accessories Reference Reference Reference
DIN-rail mounting 192T 0003 192T 0005(1)
Sealable cover 192T 0105 192T 0103 192T 0101(2)
(1) Not available for 50 A rating
(2) For 125 and 150 A ratings, use reference 192T 0103
Certificate of performance
Each class 0.2s current transformer is supplied with an individual certificate of performance, attesting to its accuracy.
K L K L
K L
75.5
85.5
107
trafo_036_a_1_x_cat
trafo_038_a_1_x_cat
trafo_162_a_1_x_cat
40 50
60 70 50 50
70 67
82
T2RB115 TRB 135
64 43 70
k I
1
k l
100
85
5
K L
31
40
LH2P2
trafo_037_a_1_x_cat
trafo_113_a_1_x_cat
0.5
52 50
65 70 50
92 112
135 1 25 to 100 A: M8 x 25
115
DIN-rail
yes yes no no
mounting
5
#HLDMRHNMR@QDCHEEDQDMSENQ31!VHSG@MC Q@SHMFR
#HLDMRHNMR@QDCHEEDQDMSENQ31!VHSG@MC Q@SHMFR
35
trafo_166_a_1_x
50 60
70 77
92
86
116
136
Associated transducers
Transducer to be associated with adapted
current transformers:
r Class 0.5.
r(MOTSNQ
r Output: UH - 8 4 +
- 0-20 mA, 0-10 V (type CEA-VA) IA
+ 7 3 -
trafo_060_a_1_x_cat
L P
Dimensions (mm)
Converter For CT Height (mm) Width (mm) Depth (mm)
trafo_071_a_1_gb_cat
Cable-through CT
References
TCA 14 TCA 21 TCA 22 T2CA 225
Class Class Class Class Class
Primary Secondary(1) 1 Reference 1 0.5 Reference 1 Reference 0.2s Reference
40 A 5A 1 192T 1404
50 A 5A 1 192T 1405
60 A 5A 1.5 192T 1406 1 VA 192T 2006
75 A 5A 1.5 192T 1407 1.5 VA 192T 2007
80 A 5A 1.5 VA 192T 2008
100 A 5A 2.5 192T 1410 1.5 VA 192T 2010 1 VA 192T 2022
125 A 5A 2.5 192T 1412 1.5 VA 192T 2012
150 A 5A 2.5 192T 1415 1.5 VA 192T 2015 1.5 VA 192T 2023 1.5 VA 192U 2215
200 A 5A 2.5 VA 192T 2020 2.5 VA 192T 2024 2.5 VA 192U 2220
250 A 5A 2.5 VA 192T 2016 3.75 VA 192T 2025 5 VA 192U 2225
300 A 5A 2.5 VA 192T 2017 3.75 VA 192T 2030 5 VA 192U 2230
400 A 5A 5 VA 192T 2034 5 VA 192U 2240
500 A 5A 5 VA 192T 2035(2) 10 VA 192U 2250
600 A 5A 5 VA 192T 2036(2) 10 VA 192U 2260
2DBNMC@QX NMQDPTDRS
#HLDMRHNMRNE3"
Accessories
TCA 14 TCA 21 TCA 22 T2CA 225
Description of accessories Reference Reference Reference Reference
DIN-rail mounting 192T 0006 192T 0006 192T 0007 192T 0003
Copper guide tube 8.5 mm (1) 192T 0020
Copper guide tube 12.5 mm(1) 192T 0021 192T 0023
Copper guide tube 16.5 mm(1) 192T 0024
Sealable cover 192T 0105
(1) For centralising cables within the CT aperture.
Dimensions
TCA 14 TCA 21 TCA 22 T2CA 225
45 45 49.5 61
k I
k I
k I
65
k I
65
22.5
65
trafo_164_a_1_x_cat
trafo_039_a_1_x_cat
trafo_042_a_1_x_cat
trafo_110_a_1_x_cat
14
78.5
75.5
27
21 22.5
27
K P1
27
K P1 K P1
24 30
31
44 47 24 28.5
62 44 48.5 KP1
40
60
Bar or cable-through CT
References
TCB 17-20 TCB 26-30 T2CB 26-30 TCB 28-30
Class Class Class Class Class Class
Primary Secondary(1) 1 Reference 0.5 1 Reference 0.2s Reference 0.5 1 Reference
50 A 5A 1 VA 192T 2305
60 A 5A 1 VA 192T 2106 1 VA 192T 2306
75 A 5A 1 VA 192T 2107 1.5 VA 192T 2307
80 A 5A 1.25 VA 192T 2108 1.5 VA 192T 2308 1.25 VA 192T 2408
100 A 5A 1.5 VA 192T 2110 1.5 VA 192T 2310 1.5 VA 192T 2410
125 A 5A 1.5 VA 192T 2112 1.5 VA 192T 2312 2.5 VA 192T 2412
150 A 5A 2.5 VA 192T 2115 1.5 VA 192T 2315 1.5 VA 192U 2315 2.5 VA 192T 2415
160 A 5A 2.5 VA 192T 2116
200 A 5A 2.5 VA 192T 2120 2.5 VA 192T 2320 2.5 VA 192U 2320 2.5 VA 192T 2420
250 A 5A 5 VA 192T 2125 5 VA 192T 2325 2.5 VA 192U 2325 2.5 VA 192T 2425
300 A 5A 5 VA 192T 2130 5 VA 192T 2330 5 VA 192U 2330 2.5 VA 192T 2430
400 A 5A 5 VA 192T 2140 5 VA 192T 2340 5 VA 192U 2340 5 VA 192T 2440
500 A 5A 5 VA 192T 2350 5 VA 192U 2350 5 VA 192T 2450
600 A 5A 5 VA 192T 2360 5 VA 192U 2360
750 A 5A 5 VA 192T 2375 5 VA 192U 2375
(1) Secondary 1 A: on request.
Accessories
TCB 17-20 TCB 26-30 TCB 26-40 TCB 32-40
Description of accessories Reference Reference Reference Reference
DIN-rail mounting 192T 0007 192T 0003 192T 0003 192T 0005
Sealable cover 192T 0105 192T 0105 192T 0103
References
TCB 44-50 TCB 44-63 T2CB 44-63
Class Class Class
Primary Secondary(1) 0.5 Reference 0.5 Reference 0.2s Reference
150 A 5A 1.5 VA 192T 5015
200 A 5A 2.5 VA 192T 5020 1.5 VA 192T 6420
250 A 5A 5 VA 192T 5025 1.5 VA 192T 6425
300 A 5A 5 VA 192T 5030 2.5 VA 192T 6430 5 VA 192U 6430
400 A 5A 10 VA 192T 5040 5 VA 192T 6440 5 VA 192U 6440
500 A 5A 10 VA 192T 5050 10 VA 192T 6450 10 VA 192U 6450
600 A 5A 10 VA 192T 5060 10 VA 192T 6460 10 VA 192U 6460
750 A 5A 10 VA 192T 5075 10 VA 192T 6475 10 VA 192U 6475
800 A 5A 15 VA 192T 5080 10 VA 192T 6480
1000 A 5A 15 VA 192T 5090 15 VA 192T 6490 10 VA 192U 6490
1200 A 5A 15 VA 192T 5092 15 VA 192T 6492 10 VA 192U 6492
1250 A 5A 15 VA 192T 5095 15 VA 192T 6493 10 VA 192U 6493
1500 A 5A 15 VA 192T 6495 10 VA 192U 6495
1600 A 5A 15 VA 192T 6494
(1) Secondary 1 A: on request.
Accessories
TCB 44-50 TCB 44-63 TCB 55-80 TCB 85-100 TCB 100-125
Description of accessories Reference Reference Reference Reference Reference
Sealable cover 192T 0102 192T 0102 192T 0102 192T 0106 192T 0106
Bar or cable-through CT
Dimensions
TCB 17-20 TCB 26-30 and T2CB 26-30 TCB 28-30 TCB 26-40
49.5 61 49.9
61
40.5
17.5
k I
10.5
k I
k I
65
70
75.5
2 k I
20.5
30.5
2
10.5
6
75.5
27
29
trafo_045_a_1_x_cat
12.5
18.5
K P1
6
K P1
32
2
trafo_044_a_1_x_cat
K P1
trafo_041_a_1_x_cat
33
15.5 10.5
trafo_055_b_1_x_cat
K P1
20.5 30.5 20.5
28.5 40 30.5 32
48.5 60 40
60
TCB 32-40 and T2CB 32-40 TCB 44-50 TCB 44-63 and T2CB 44-63
71 86 96
k I k I k I
88.5
105.5
98.5
30.5
32
30.5
16
30.5
12.5
10.5
4
4
4
36.75
4
43.25
48.25
K P1
trafo_040_a_1_x_cat
KP1
trafo_043_a_1_x_cat
KP1
10.5
trafo_046_a_1_x_cat
40.5 40.5
50.5 50.5
50
65 63.5
70
85 70
95
k I
184.8
184.8
10.5
123.5
30.5
31
51
31
51
0
10
5
5
5
58.5
82
82
trafo_048_a_1_x_cat
KP1
trafo_049_a_1_x_cat
k-P1
k-P1
trafo_047_a_1_x_cat
60.5 95
80.5 81
95 95 101
120 101 121
122 172
172
Bar or cable-through CT TCB 17-20 TCB 26-30 T2CB 26-30 TCB 26-40 TCB 28-30 TCB 32-40 T2CB 32-40
30 x 10 (x 1) / 30 x 10 (x 1) / 40 x 12 (x 1) / 40 x 10 (x 1) / 40 x 10 (x 1) /
Bar (mm) 20 x 5 (x 1) 30 x 10 (x 1)
20 x 10 (x 12) 20 x 10 (x 12) 32 x 18 (x 1) 30 x 5 (x 12) 30 x 5 (x 12)
cable (mm) 17.5 26 26 26 28 32 32
H x W x D (mm) 65 x 49.5 x 50 75.5 x 61 x 48 75.5 x 61 x 48 75.5 x 61 x 48 70 x 49.9 x 68 88.5 x 71 x 58 88.5 x 71 x 58
DIN-rail mounting yes yes yes yes no yes yes
Bar or cable-through CT TCB 44-50 TCB 44-63 T2CB 44-63 TCB 55-80 TCB 85-100 TCB 100-125
80 x 10 (x 1) /
50 x 12 (x 1) / 63 x 10 (x 1) / 63 x 10 (x 1) / 100 x 10 (x 12) / 123 x 30 (x 1) /
Bar (mm) 60 x 30 (x 1) /
40 x 10 (x 12) 50 x 10 (x 12) 50 x 10 (x 12) 80 x 10 (x 13) 100 x 10 (x 13)
60 x 10 (x 12)
cable (mm) 44 44 44 55 85 100
H x W x D (mm) 98.5 x 86 x 58 105.5 x 96 x 58 105.5 x 96 x 58 123.5 x 120 x 58 184.5 x 172 x 52 184.5 x 172 x 52
Associated transducers
trafo_060_a_1_x_cat
rOutput:
- 0-20 mA, 0-10 V (model CEA-VA),
l 6 2 +
trafo_074_a_1_cat
L P Dimensions (mm)
Converter For CT Height (mm) Width (mm) Depth (mm)
Type 1 TCB 26-30 50.5 60 32.5
Type 1 TCB 26-40 50.5 60 32.5
trafo_071_a_1_gb_cat
H
Bar-through CT
References
TBA 60 TBA 80 TBA 100 T2BA 100
Class Class Class Class Class
Primary Secondary 0.5 1 Reference 0.5 Reference 0.5 Reference 0.2s Reference
200 A 5A 2.5 VA 192T 7020
250 A 5A 2.5 VA 192T 7025
300 A 5A 2.5 VA 192T 7030 2.5 VA 192T 7530
400 A 5A 5 VA 192T 7040 5 VA 192T 7540
500 A 5A 5 VA 192T 7050 5 VA 192T 7550
600 A 5A 10 VA 192T 7060 5 VA 192T 7560 5 VA 192T 8060
750 A 5A 10 VA 192T 7075 5 VA 192T 7575 5 VA 192T 8075
800 A 5A 10 VA 192T 7080 10 VA 192T 7580 5 VA 192T 8080
1000 A 5A 15 VA 192T 7090 15 VA 192T 7590 5 VA 192T 8090
1200 A 5A 15 VA 192T 7092 15 VA 192T 7592 10 VA 192T 8092 5 VA 192U 8092
1250 A 5A 15 VA 192T 7093 15 VA 192T 7593 10 VA 192T 8093 5 VA 192U 8093
1500 A 5A 15 VA 192T 7095 15 VA 192T 7595 15 VA 192T 8095 5 VA 192U 8095
1600 A 5A 15 VA 192T 7094 15 VA 192T 7594 15 VA 192T 8094
2000 A 5A 15 VA 192T 7596 15 VA 192T 8096 5 VA 192U 8096
2500 A 5A 30 VA 192T 8097 10 VA 192U 8097
3000 A 5A 30 VA 192T 8098(1) 10 VA 192U 8098
4000 A 5A 30 VA 192T 8099(1)
#HLDMRHNMR@QDCHEEDQDMSENQ3! VHSG@MC OQHL@QX
Accessories
TBA 60 TBA 80 TBA 100 T2BA 100 TBA 103 T2BA 103 TBA 127 T2BA 127
Description of accessories Reference Reference Reference Reference Reference Reference Reference Reference
Sealable cover 192T 0102 - 192T 0102 192T 0102 - - 192T 0102 192T 0102
Dimensions
TBA 60 TBA 80 TBA 100 and T2BA 100
k I
117
k I
84
129
31
214
55.5
59
60
trafo_050_a_1_x_cat
trafo_059_a_1_x_cat
trafo_082_a_1_x_cat
S2 S1
96.5
k-P1
50 34 k-P1
60.5 69
88 96
100
100.5
129
TBA 103 and T2BA 103 TBA 127 and T2BA 127
S2 S1
150
38
103
175
128
69
trafo_054_a_1_x_cat
trafo_052_a_1_x_cat
17.5
LP2
41
17
99
17.7 42.8 17.7
100
Bar-through CT TBA 60 TBA 80 TBA 100 T2BA 100 TBA 103 T2BA 103 TBA 127 T2BA 127
Bar (mm) 60 x 30 84 x 34 100 x 55 100 x 55 103 x 41 103 x 41 128 x 38 128 x 38
H x W x D (mm) 129 x 88 x 78 117 x 96 x 68 167 x 129 x 78 (1) 167 x 129 x 78 150 x 99 x 58 150 x 99 x 58 175 x 100 x 55 175 x 100 x 55
#HLDMRHNMR@QDCHEEDQDMSENQ3! VHSG@MC OQHL@QX
Dimensions
TCB3 18-20 TCB3 22-30
35 35 45 45
k I k I k I
18 k I k I k I 22
75
65
10
5
trafo_111_a_1_x_cat
trafo_112_a_1_x_cat
L1 KP1 L2 L3
L1 KP1 L2 L3
20 30
115 150
References
TCA 13 - 3P
Class
Primary Secondary(1) 1 Reference
3 x 50 A 5A 1 VA 192T 1905
3 x 60 A 5A 1.25 VA 192T 1906
3 x 75 A 5A 1.5 VA 192T 1907
3 x 80 A 5A 1.5 VA 192T 1908
3 x 100 A 5A 2.5 VA 192T 1910
3 x 125 A 5A 2.5 VA 192T 1912
3 x 150 A 5A 2.5 VA 192T 1915
3 x 160 A 5A 2.5 VA 192T 1916
(1) Secondary 1 A: on request.
Dimensions
TCA 13 3P
54
44
L 7
Split-core CT
References
TO 23 TO 58 TO 812 TO 816
Class Class Class Class Class Class Class
Primary Secondary 1 3 Reference 0.5 1 Reference 0.5 1 Reference 0.5 Reference
100 A 5A 1.25 VA 192T 4601
150 A 5A 1.5 VA 192T 4602
200 A 5A 2.5 VA 192T 4603
250 A 5A 1.5 VA 192T 4604 1.5 VA 192T 4625 1.5 VA 192T 4725
300 A 5A 3.75 VA 192T 4605 2.5 VA 192T 4630 2.5 VA 192T 4730
400 A 5A 5 VA 192T 4606 1 VA 192T 4640 2.5 VA 192T 4740
500 A 5A 2.5 VA 192T 4650 2.5 VA 192T 4750
600 A 5A 2.5 VA 192T 4660 2.5 VA 192T 4760
750 A 5A 2.5 VA 192T 4675 2.5 VA 192T 4775
800 A 5A 2.5 VA 192T 4680 2.5 VA 192T 4780
1000 A 5A 5 VA 192T 4610 5 VA 192T 4710 10 VA 192T 4810
1250 A 5A 7.5 VA 192T 4712 10 VA 192T 4812
1500 A 5A 7.5 VA 192T 4715 10 VA 192T 4815
1600 A 5A 10 VA 192T 4814
2000 A 5A 10 VA 192T 4820
2500 A 5A 10 VA 192T 4825
3000 A 5A 15 VA 192T 4830
4000 A 5A 15 VA 192T 4840
5000 A 5A 15 VA 192T 4850
Dimensions
B C Dimensions (mm)
D
Type A (mm) B (mm) C (mm) D (mm) E (mm)
TO 23 106 93 58 23 33
TO 58 158 125 58 55 85
TO 812 198 155 58 85 125
trafo_078_e_1_x_cat
Fixed by M5 new
Summation CT
Reference
BSA 02 BSA 03 BSA 04
Primary Secondary Reference Reference Reference
5 + 5/5 A 5A 192T 0802
5 + 5 + 5/5 A 5A 192T 0803
5 + 5 + 5 + 5/5 A 5A 192T 0904
Dimensions
BSA 02 et BSA 03 BSA 04
57 65
136.5
90
29.5
54
trafo_073_b_1_x_cat
trafo_069_b_1_x_cat
50 55 95 60
80 122
127 156
shunt_008_a_1_cat
shunt_007_b_1_cat
shunt_006_b_1_cat
Function
SOCOMEC shunts provide indirect measurement of direct current by creating
a standardised voltage drop.
Characteristics
q Voltage drop: 100 mV q (MRQ@SHMF
for nominal rating. q 5 In / 5s rating 600 to 1500 A
q Accuracy class: 0.5. q (MRQ@SHMF
q Permanent overload: 1.2 In.
References
DIN series
Rating(1) Secondary voltage drop Reference
1A 100 mV 192S 2101
4A 100 mV 192S 2104
6A 100 mV 192S 2106
10 A 100 mV 192S 2110
15 A 100 mV 192S 2112
25 A 100 mV 192S 2114
40 A 100 mV 192S 2116
60 A 100 mV 192S 2118
100 A 100 mV 192S 2120
150 A 100 mV 192S 2125
200 A 100 mV 192S 2220
250 A 100 mV 192S 2235
300 A 100 mV 192S 2230
400 A 100 mV 192S 2240
600 A 100 mV 192S 2250
1000 A 100 mV 192S 2255
1500 A 100 mV 192S 2260
2500 A 100 mV 192S 2165
4000 A 100 mV 192S 2170
6000 A 100 mV 192S 2175
(1) Other ratings : Please consult us.
Dimensions
DIN Series: 1 to 25 A
Fig. 1
B Rating(1) Figure A B C D E F G H I
1A 1 90 28 20 8 78
11 F
4A 1 90 28 20 8 78
6A 1 90 28 20 8 78
10 A 1 90 28 20 8 78
15 A 1 90 28 20 8 78
25 A 1 90 28 20 8 78
shunt_011_a_1_x_cat
135
40 A 2 123 33 20 8 103
115 60 A 2 123 33 20 8 103
A 100 A 2 123 33 20 8 103
H 150 A 2 123 33 20 8 103
200 A 2 168 55 30 15 10 10 128 30
250 A 2 168 55 30 15 10 10 128 30
300 A 2 168 55 40 20 10 10 128 30
30
F
F
shunt_010_a_1_x_cat
C
E
shunt_009_a_1_x_cat
C
D
H
A H
A
(military standard).
Other regulations
Characteristics Dimensions
H1 L
Case degree of protection IP55 H F
Terminal protection degree IP20
Connection cross-section 2.5 mm2
Weight 82 g
pti_003_a_1_x_cat
Rating (A) D1 E F H H1 I L
E
D1
2.5
2
Use
trans_116_a_1_gb_cat
1.5
The protection transformers are used for 1
thermal relays. They protect the low power
terminal relays against the motor inrush 0.5
current.
Primary current (In)
Available in primary wound version for current
1 2 3 4 5
between 1 to 75 A - (1 A secondary, 2 VA, Cl.
1). Please consult us. References
Rating (A) Secondary Class 1 Reference
100 1A 2 192T 0710
150 1A 2 192T 0715
200 1A 2 192T 0720
300 1A 2 192T 0730
400 1A 2 192T 0740
500 1A 2 192T 0750
trans_117_a_1_x_cat
20 5 3000
- Accuracy at +150 C: 0,33 C.
6,5
30 10 3000
300 A 192Y 0430 192Y 0530 192Y 0830 192Y 0630 192Y 0930
400 A 192Y 0440 192Y 0540 192Y 0840 192Y 0640 192Y 0940
500 A 192Y 0450 192Y 0550 192Y 0850 192Y 0650 on request
600 A 192Y 0460 192Y 0560 on request on request 192Y 0960
750 A 192Y 0475 on request 192Y 0875 192Y 0675 192Y 0975
800 A 192Y 0480 192Y 0580 192Y 0880 192Y 0680 192Y 0980
Measurement and conversion of the input Voltage transformers are used specifically for supplying measurement
value read at the primary of a transformer in a equipment, therefore it is not recommended to connect other components
directly proportional voltage signal. which could affect accuracy. This is due to the effect of the phase shift
BTV 25 products are voltage transformers. error. If the consumption is greater than 25 VA, another transformer must
be added.
Characteristics References
Primary Secondary Power Reference
Accuracy class 1% 230 VAC 100 VAC 25 VA 192M 2020
Dielectric quality 3 kV for 1 min. 400 VAC 100 VAC 25 VA 192M 2030
Operating frequency 50 - 60 Hz 440 VAC 100 VAC 25 VA 192M 2044
Permanent overload 1.2 Un 500 VAC 100 VAC 25 VA 192M 2050
600 VAC 100 VAC 25 VA 192M 2060
660 VAC 100 VAC 25 VA 192M 2066
Connection 800 VAC 100 VAC 25 VA Please consult us
Dimensions
Secondaire a b 103
trafo_072_a_1_gb_cat
70 112
trafo_070_a_1_x_cat
97
Primaire A B
R
R 3.25
100
104
56
83
70
N(S)
96
Measurement devices
& power quality
Transducers
They provide conversion of an AC electrical value (A, V, Hz, Cos phi, W, Var)
into a DC signal, with standardised current or voltage.
They are available in surface-mount casings (CS range).
trans_071_a_2_cat
These devices are designed for DIN rail or back plate mounting.
Type CS transducers are available in two sizes:
q 75 mm for current, voltage and frequency converters,
q 150 mm for power or three-phase converters.
Consult us.
Modular transducers
Available in:
q 3-DIN module housings (52.5 mm) for current,
voltage and frequency converters,
trans_076_a_2_cat
q 6-DIN module housings (105 mm) for current (output 4-20 mA),
voltage (output 4-20 mA) converters,
q 9-DIN module housings (157.5 mm) for power or three-phase converters.
Consult us.
Analogue meters
Selector switches
Digital meters
They measure all types of electrical values (A, V, Hz, Cos phi, P, Q...).
The range:
amper_032_a_2_cat
cosph_001_a_2_cat
voltm_019_a_2_cat
Hour counters
Often combined with analogue meters in an electrical panel, hour counters count
compt_001_a_2_cat
new new
Core balance
RESYS P40 transformers type A
p. 520 p. 522
CORPO 213A
Protection against overvoltages
new new
SURGYS SURGYS SURGYS
G51-PV G100-F G140-F
p. 526 p. 528 p. 530
new
SURGYS SURGYS SURGYS
G50-FE G40-FE G70
p. 532 p. 534 p. 536
n ew
SURGYS SURGYS SURGYS
D40 E10 Low current
p. 538 p. 540 p. 542
All electrical installations, particularly those With long-term experience in industry Important:
which incorporate sensitive receivers, must and complete knowledge of installation
protection
Electronic
be appropriately protected or monitored standards, SOCOMEC guarantees much Sound knowledge of your electrical
against indirect contact, earth leakage more than the supply of high-performance network is essential to ensure the
currents, short circuits or even temporary products. Our expertise extends to services successful outcome of your protection
voltage surges. such as: project.
q audits of your LV installation, In fact, the choice of electronic
In the section titled Electronic protection, q defining protection requirements, protection products and their place of
we have grouped together all the devices q perfect integration of products in your installation depend on:
which protect your installation against these electrical distribution system, qSGDSXODNESGDRTOOKXRNTQBD
various hazards: q commissioning, qSGDKDMFSGNESGDBNMCTBSNQR
q RESYS earth leakage relays q product training and related installation qSGDSXOD@MCM@STQDNESGDDKDBSQHB@K
Please refer to our "Differential protection" standards, receivers connected to the network.
selection guide p. 512. q provision of turnkey supervision solutions.
q SURGYS surge arresters
Please refer to our "Protection against
overvoltages" selection guide p. 514. Contact us now to see how we can help
Services & Technical
with your project.
Assistance:
Our expertise at your service.
p. 14
SITE 221 A
SOCOMEC's SURGYS surge protection Designed for compatibility with all types of The benefits of varistor technology:
device ensures the electrical receivers are electrical installation The majority of SURGYS surge protection
protected against temporary voltage surges SURGYS surge protection devices cover both devices are based on varistor technology.
from various sources: strong and weak currents. Different versions The use of varistors offers numerous benefits,
q indirect effects of a lightning strike, are available depending on: including the flow of a significant discharge
q operations on an industrial network, q the type or class of tests current and the absence of follow current. The
q disruptive loads (switched-mode power (1, 2, 3 or weak currents), absence of follow current is a major benefit as
supplies, inductive loads, etc.). q the operating voltage (Uc), it is responsible for tripping the installation's
Lightning rods are selected on the basis of q the network configuration (single-phase / residual differential protection devices.
normative criteria (e.g. minimum In value) and three-phase with or without neutral / DC), In addition, some versions of the SURGYS
installation-specific constraints (e.g. high q the level of discharge currents (Iimp, Imax, In), protection devices (G40-FE, D40 and E10
lightning density with use of a corresponding in differential mode and the weak current
q the protection level (Up),
discharge current). range) use other technology (varistor/arrester
q the protection technology (varistors,
or arrester/diode combinations) which can
arresters, clipping diodes),
significantly improve the level of protection.
q the functions (differential mode, pluggability,
remote signalling, etc.).
Which
Which need?
application?
protection
Electronic
new new
Which type of
protection?
Isolated sites
new
RESYS M40R
p. 518
A type
30 mA 30 A
0 10s
2
Modular
44
new n ew new
Protection
Type Type 2 Types 1 and 2 Type 1 Types 1 and 2 Types 1 and 2
Mode MC / MD (*) MC MC MC MC / MD
Characteristics
500 - 600 - 800 -
Nominal voltage Un 230 / 400 VAC 230 / 400 VAC 230 / 400 VAC 230 / 400 VAC
1000 - 1500 VDC (*)
Neutral system TT, TN, IT TT, TN, IT TT, TN, IT TT, TN
600 - 720 - 960 -
Voltage UC 400 VAC 400 VAC 400 VAC 400 VAC
1200 - 1800 VDC (*)
Level of protection UP 2.2 - 2.8 - 2 - 2.2 - 4.5 kV 2 kV 2.5 kV 1.3 kV 1.5 kV
Nominal discharge current In 15 kA 40 kA 50 kA 12.5 kA 20 kA
Max. discharge current Imax 40 kA 100 kA 140 kA 50 kA 40 kA
Discharge current Iimp (per pole) 25 kA 25 kA 12.5 kA 15 kA
Plug-in modules
Remote signalling (*)
MC: Common Mode with respect to earth.
MD: Differential Mode between active conductors.
(*) specific to the reference
Sites exposed to frequent lightning strikes or industrial networks Sensitive electrical receivers
Strategic installations subject to lightning strikes
subject to operational voltage surges or loads
Protection of RS422/485
Bus protection Protection of analogue line,
connection, T2 digital phone
(Profibus, Fieldbus, modem, autocom, phone alarm,
connection, Ethernet 10baseT
LONworks, Interbus) ADSL
connection
new new n ew
Type 2 Type 2 Types 2 and 3 Low currents Low currents Low currents
MC MC / MD (*) MC / MD (*) MC / MD MC / MD MC / MD
230 / 400 VAC 230 / 400 VAC 230 / 400 VAC (*) 6V 48 V 150 V
400 VAC 255 - 400 VAC (*) 255 - 400 VAC (*) 8V 53 V 170 V
> Manufacturing.
Electronic
Strong points
Applications
RESYS M40
resys_050_d_1_x_cat
300 m A BE 2
BE 3
Case
Type modular
Number of modules 2.5
45
61
85
Dimensions W x H x D 44 x 85 x 63.5
resys_056_a_1_x_cat
For single phase applications, only the live and neutral need to be passed
RESET TEST
through the C.T.
50 m max Cabling: for distances > 1 m, use twisted pair cable between the unit and C.T.
Do not connect the shield to earth.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
230 V 115 V O
RESYS M40
References
RESYS M40
Auxiliary power supply Us(1) Reference
115 / 230 VAC 4941 3723(2)
400 VAC 4941 3740(2)
12 125 VDC 4941 3602(2)
(1) Other rating: Please consult us. (2) References and characteristics of closed, split core and rectangular toroids: see Core balance transformers type A p. 522.
resys_082_a_1_cat
Strong points
Advantages
Automatic reclosing Applications
This function provides protection, particularly
in isolated sites or for processes requiring
a restart in the event of transient faults
(continuity of service ensured in the absence
of a maintenance team).
Fully configurable
q CITRSLDMSNE(MEQNL
SN
RESYS M40R
q Time delay 0 to 10 s.
situation.
Tripping accuracy
by TRMS measurement. RESYS M40R
Improves immunity to nuisance tripping.
The RESYS M40R relay must be combined with an auto-
Instantaneous display of permanent matic tripping/reclosing breaking device:
leakage currents. - a motorised switch
The LED bargraph provides a real-time display - a device fitted with an undervoltage coil
of fluctuations in leakage currents. - a contactor.
Front panel
CITRSLDMS(M
2 - "ON" LED.
1$2$3OTRGATSSNM
4 - TRIP alarm LED.
resys_078_a_1_x_cat
+$#!@QFQ@OGW(M
6 - "TEST" pushbutton.
7 - Time delay setting.
Characteristics
Auxiliary power supply Us Alarm
Frequency v'Y automatic reset
Alarm configuration mode
"NODQ@SHMFYNMD 0.8 1.15 Us (6x max, then recording)
#"NODQ@SHMFYNMD 0.8 1.05 Us Reset manual by pushbutton / using terminal
Max. consumption 5 "6#" Output contacts
Insulation (according to IEC 60664-1 standard) Number of contacts 2
Rated insulation voltage 5 " Type of ALARM 1 contact inverter
Rated impulse voltage
J55 "J55 " Type of ALARM 2 contact simple
Degree of pollution "K@RR Characteristics contact ALARM 1 5 " 5
Threshold values Characteristics contact ALARM 2 5 " 5
(MRDSSHMF
ALARM 1 operating mode negative security(1)
Accuracy of tripping v(M ALARM 2 operating mode positive security (1)
Domain of network frequency v'Y (1) Negative security: relay activated in case of alarm / Positive security: relay not activated in
case of alarm.
Time delay setting
R
Reclosing
Operating conditions
Nb of automatic reclosing attempts 6 max
Operating temperature - 20 + 55 C
Time delay between two reclosing
R
Storage temperature v
"
Reset of automatic reclosing counter (tCR) 15 min.
Case
Type modular
resys_056_a_1_x_cat
For single phase applications, only the live and neutral need to be passed
RESET TEST through the C.T.
resys_079_a_1_x_cat
50 m max
Cabling: for distances > 1 m, use twisted pair cable between the unit and C.T.
Do not connect the shield to earth.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
230 V 115 V O
RESYS M40R
References
RESYS M40R
Auxiliary power supply Us(1) Reference
5 " 4941 3724
5 " 4941 3741
(1) Other rating: Please consult us.
> Manufacturing.
Electronic
resys_081_a_1_cat
Strong points
the device.
Tripping accuracy by TRMS measurement.
Improves immunity to nuisance tripping.
Improved immunity to EMC interferences
The device has new electronics which improve
electromagnetic compatibility.
Applications
300 mA
BE 2
BE 3
Front panel
(MRDSSHMF
2. Time delay setting.
"NMEHFTQ@SHNMLHBQNRVHSBGDRW
resys_081x_a_2_cat
5
6 4. "ON" LED.
7 5. "RESET" pushbutton.
8 6. TRIP alarm LED.
+$#A@QFQ@OGW(M
8. "TEST" pushbutton.
1 2 3 4
"G@Q@BSDQHRSHBR
Auxiliary power supply Us Alarm
Frequency v'Y Alarm configuration mode RSNQ@FD@TSNL@SHBQDRDS
"NODQ@SHMFYNMD 0.8 1.15 Us Alarm factory setting storage
#"NODQ@SHMFYNMD 0.8 1.05 Us Reset L@MT@KAXOTRGATSSNMTRHMFSDQLHM@K
"NMRTLOSHNM 5 "6#" Output contacts
Insulation (according to IEC 60664-1 standard) Number of contacts 2
Rated insulation voltage 5 " 3XODNE + 1,BNMS@BS 5 " 5
Rated impulse voltage
J55 "J55 " 3XODNE + 1,NQ/1$ + 1,BNMS@BS 5 " 5
Degree of pollution "K@RR + 1,NODQ@SHMFLNCD ONRHSHUDMDF@SHUDRDBTQHSX(1)
Threshold values + 1,NQ/1$ + 1,NODQ@SHMFLNCD positive security(1)
%@BSNQXRDSSHMFNE + 1,NODQ@SHMFLNCD negative security
(MRDSSHMF
%@BSNQXRDSSHMFNE + 1,NODQ@SHMFLNCD positive security
Accuracy of tripping v(M (1) Negative security: relay activated in case of alarm / Positive security: relay not activated in
Domain of network frequency v'Y case of alarm.
Operating conditions
Time delay setting
4 - 10 s
/1$ + 1,QDK@XSQHOOHMF (M Operating temperature v
"
'XRSDQDRHRNESGD/1$ + 1,QDK@X (M Storage temperature v
"
"@RD
Type panel mounting
Dimensions W x H x D 48 x 48 x 107
"@RDOQNSDBSHNMHMCDW IP40
48
resys_057_b_1_x_cat
"@AKHMFENQCHRS@MBDRLTRDSVHRSDCO@HQB@AKDADSVDDMSGDTMHS@MC"
3
RESET TEST
Do not connect the shield to earth.
resys_055_b_1_x_cat
50 m max
1 2 3 4 5 6
(-)
7
(+) 8 9 10 11 12
230 V
RESYS P40
References
RESYS P40
Auxiliary power supply Us(1) Reference
5 " 4942 3711(2)
5 " 4942 3723(2)
v5#" 4942 3602(2)
(1) Other rating: Please consult us. (2) References and characteristics of closed, split core and rectangular toroids: see "Core balance transformers type A" p. 522.
Description of accessories Reference
Soft protection cover IP65 4942 0000
> Industry.
protection
> Infrastructure.
Electronic
tore_015_a_1_cat
tore_016_a_1_cat
CORE BALANCE
TRANSFORMER (WR)
Strong points
systems (6IC).
> A patented cable locator
(6IC).
CORE BALANCE
TRANSFORMER (6IC)
Function Conformity to standards
The installation of protection or signalling The core balance transformers (toroids) > IEC 60044-1
resources such as earth leakage protection proposed by SOCOMEC meet requirements
relays involves the use of core balance in terms of measurement sensitivity and are
transformers. suitable for earth leakage protection relays
Active conductors pass through the aperture RESYS M40/P40 and DIRIS A80.
of the core balance transformer, providing "KNRDCRDQHDR("61@MC3%1NQ
the differential summation of vector currents ROKHSBNQDRDQHDR62SXODRRTHS@KKVHQHMF
which enables the detection of leakage configurations.
currents.
Advantages
A complete product range A patented cable locator (6IC)
q All dimensions and types are available q The SOCOMEC cable locator is a patented
for compatibility with any bar and cable innovation. The cable is perfectly centralised
configurations or diameters. in the core balance transformer to ensure
A wide range of fixing systems (6IC) accurate measurement and enhanced
q 6IC core balance transformers can be immunity to network interferences. It also
mounted on DIN-rail, on back-plate or enables direct mounting of the core balance
directly on the cable. These products can transformer onto the cable.
be adapted into confined spaces with high
integration constraints and provide easy
and rapid cabling.
Implementation
All of the active conductors must be passed
through the detection toroid's aperture. Installation of the detection toroids
The protective conductor must pass on the PE N L1 L2L3 PE N L1 L2 L3 L+ L-
outside of the toroid or pass once for each
direction.
isom_087_a_1_x_cat
Characteristics
Dimensions
"KNRDCSNQNHCR("RDQHDR
Dimensions (mm)
A E Weight
Type A B C D E F G (kg)
(" 53 17.3 27.8 50 26 81 M4 0.10
(" 92 30 50 85 26 103.5 M4 0.13
(" 102.5 50 50 90 26 125 M5 0.18
B (" 116 80 75 105 26 142.5 M5 0.22
(" 163 120 100 150 26 182.5 M6 0.38
F
tore_032_a_1_x_cat
B
H
A
A
Detail A
D
B
D
2.5
G F
F
C
tore_027_f_1_gb_cat
tore_024_a_1_x_cat
2,5
6,1
Dimensions (continued)
2OKHSBNQDSNQNHCR62RDQHDR
45
Dimensions (mm)
Weight
Type A B C D E (kg)
6.3
62W 50 80 78 114 145 0.9
62W 80 80 108 144 145 1.1
62W 80 120 108 144 185 1.4
C
D
A
32 32
E 59
References
"KNRDCSNQNHCRSXOD ("RDQHDR
Type Rated operational current In (A) Toroid diameter (mm) Reference
(" 36 15 4950 6015(1)
(" 65 30 4950 6030(1)
(" 85 50 4950 6050(1)
(" 160 80 4950 6080(1)
(" 250 120 4950 6120(1)
(" 400 200 4950 6200(1)
(" 630 300 4950 6300(1)
(1) Toroids for RESYS relays M40 / P40 and DIRIS A80.
1DBS@MFTK@QBKNRDCSNQNHCRSXOD 61@MC3%1RDQHDR
Type Toroid diameter (mm) Reference
61W 70 x 175 4795 0717(1)
61W 115 x 305 4795 1130(1)
61W 150 x 350 4795 1535(1)
TFR 200 x 500 200 x 500 4795 2050(1)
(1) Toroids for RESYS relays M40 / P40 and DIRIS A80.
BBDRRNQHDRENQ("SNQNHCR
Cable locator
Enables the cables to be centred in the toroids aperture. Use of this accessory allows the core
terre_040_a_1_cat
balance transformer to be directly mounted onto the cables.
Mounting bracket
terre_038_a_1_cat
,NTMSHMFAQ@BJDSLL 4950 0001
,NTMSHMFAQ@BJDSLL 4950 0002
,NTMSHMFAQ@BJDSLL 4950 0003
,NTMSHMFAQ@BJDSLL 4950 0003
,NTMSHMFAQ@BJDSLL 4950 0004
,NTMSHMFAQ@BJDSLL 4950 0005
terre_042_a_1_cat
Detachable screw terminal 4950 0041
terre_043_a_1_cat
Sealable protection cover 4950 0020
DIN-rail clip
For DIN-rail mouting SOCOMEC core balance transformers
terre_037_a_1_cat
sgys_076_a_1_cat
Strong points
Applications
Main incoming protection in a photovoltaic network:
q SURGYS G51-PV is installed on the DC side, in the combiner box, close to the solar cell strings, for
protecting the downstream DC equipment from the indirect effects of lightning.
q SURGYS AC, SURGYS D40 for instance, is installed downstream of the inverter for load protection.
sgys_077_a_1_x_cat
120
Iscw 15/0
pv 2.2/440
.4
70
A 120
Iscw 15/0
pv 2.2/440
.4
70 120
A
Iscw 15/0
pv 2.2/440
.4
70
A
Case
D
LNCTKDRCHLDMRHNMR6W'W#5#" 54 x 90 x 77 mm
H
sgys_091_a
Strong points
SURGYS G100-F 1 pole
Applications
q Upstream location of the distribution surge
arresters.
q TGBT + building protected against lightning
either:
- through lightning conductors
Lightning rod
- through mesh cages.
q TGBT in buildings subjected to high level
risk of lightning strikes such as classified
installations, installations located in areas
prone to high density of lightning strikes,
high-rise buildings, presence of antenna G1
SURGYS
towers, chimneys.
00-
F
G1
00-
F
G100-F
q Sites located at high altitude.
q Distribution board of a building with presence
of Lightning Protection Systems.
sgys_086_a_1_gb_cat
SURGYS
E10
Connection
Series arrangement Parallel arrangement
L1 L1 L1 L1
L2 L2 L2 L2
L3 L3 L3 L3
N N N N
BT network Installation
DP ( 125 A) Installation DP
BT network
L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N
T: Remote signalling
T
sgys_085_a_1_gb_cat
12
11
sgys_084_a_1_gb
14
14
11
12
References
SURGYS G100-F
No. of poles Number of side-by-side modules Reference
2 4 4981 1020
3 6 4981 1030
4 8 4981 1040
Description of accessories Reference
Spare plug-in module m-G100-F 4981 1019
> Industry.
protection
FULWLFDOQRQFULWLFDO
sgys_054_b_1_cat
Modular design
Easy assembling.
Applications
q Upstream location of the distribution surge
arresters
q TGBT + building protected against lightning
DHSGDQSGQNTFGKHFGSMHMFBNMCTBSNQR
- through mesh cages.
Lightning rod
q TGBT in buildings subjected to high level risk of
lightning strikes such as classified installations,
installations located in areas prone to high
density of lightning strikes, high-rise buildings,
presence of antenna towers, chimneys.
q Sites located at high altitude. SURGYS
q Distribution board of a building with presence of G1
40-
F
G1
40-
F
G140-F
Lightning Protection Systems.
sgys_016_d_1_gb_cat
SURGYS SURGYS
D40 E10
sgys_054x_b_2_cat
q Remote signalling contact.
q Absence of follow current. 1
q Possibility of parallel or series arrangement.
q %TRDBNLAHM@SHNMRVHSBGQDBNLLDMCDC 2 3
%42$1!+."RDDO@FD188).
Case Characteristics
L P Network
35 Network type 230 / 400 VAC
Neutral systems TT-TN-IT
Nominal voltage Un 400 VAC
Maximum voltage Uc 400 VAC
sgys_011_a_1_gb_cat
Protection characteristics
Level of protection Up 2.5 kV
,@WHLTLCHRBG@QFDBTQQDMSRGNBJR(max 140 kA
-NLHM@KCHRBG@QFDBTQQDMSRGNBJRR(n 50 kA
Residual voltage at Iimp 1.5 kV
Type modular (LOTKRDBTQQDMSRGNBJR(imp 25 kA
2P dimensions W x H x D 70 x 90 x 67 mm Mode of protection common
3P dimensions W x H x D 105 x 90 x 67 mm Associated characteristics
Residual current Ic < 2 mA
Dimensions W x H x D in 4 poles 140 x 90 x 67 mm
Response time tr < 25 ns
Case degree of protection IP20 Follow current If none
Terminal block degree of protection IP20 Rated conditional short circuit current Icc 50 kA
Case material polycarbonate UL94-5VA Recommended disconnectors fuses gG 125 A
Network connection cross-section 10 50 mm2 Type of disconnection indicator mechanical
Number of disconnection indicators 3
Earth connection cross-section 10 50 mm2
Remote signalling contact
Number of contacts per pole 1
Connection Contact type inverter
AC making capacity 3A
Series arrangement DC making capacity 2A
L1 L1 AC nominal voltage 125 VAC
L2 L2 DC nominal voltage 30 VDC
L3 L3
N Sustained current 2A
N
Connection type screw block
DP ( 125 A) Installation Max. cross-section of terminal connections 1.5 mm2
LV network
L/N L/N L/N L/N L/N L/N L/N L/N Operating conditions
T: Remote signalling
Operating temperature v
"
sgys_025_b_1_gb_cat
Parallel arrangement
L1 L1
L2 L2
L3 L3
N N
LV network Installation
DP
SURGYS G100-F
No. of poles Number of side-by-side modules Reference
2 2 4981 1521
T
3 3 4981 1531
4 4 4981 1541
> Industry.
protection
non critical).
sgys_090_a
Applications
q Main switchboard or main distribution panel
of a building, equipped with electronic devices
(multi-function measurement devices, PLC,
etc.) with presence of lightning conductors or
protection through meshed cages.
Lightning rod
q Main switchboard equipped with electronics
in buildings subjected to high level risk of
lightning strikes such as classified installations,
installations located in areas prone to high
density of lightning strikes, high-rise buildings.
q Main switchboard equipped with PLC, BMS
SURGYS
or CTM, remote monitoring, technical alarms, G5
0-F
E
G50-FE
G5
0-F
E
modems...
q High-rise buildings safety main switchboard.
q Lift machinery unit located in the higher
part of the building.
sgys_089_a_1_gb_cat
DC making capacity 2A
AC nominal voltage 250 VAC
DC nominal voltage 30 VDC
Sustained current 2A
9
Connections
Parallel arrangement
L1
L2
L3
N
BT network Installation
DP
T : Remote signalling
DP : Protection device
L L L N (Fuses)
sgys_088_b_1_gb_cat
References
SURGYS G50-FE
No. of poles Number of side-by-side modules Reference
2 2 4981 0520
3 3 4981 0530
4 4 4981 0540
Description of accessories Reference
Spare plug-in module m-G50-FE 4981 0519
> Industry.
protection
Strong points
SURGYS G40-FE 2 poles > Recommended in case
of risk of direct impact
of lightning strikes.
Function > Varistor technology.
The SURGYS G40-FE surge arrester is designed to ensure the protection of your low voltage > End of service life indicator.
distribution installations and your electrical equipment. It acts against industrial operation
overvoltages and overvoltages owing to lightning. > Remote signalling.
This type of Surge Protective Device is particularly recommended in case of risk of direct impact > Thermal disconnector.
of lightning strikes at the main switchboard level, containing electronic devices sensitive to
overvoltages.
Conformity to standards
Advantages > NF EN 61643-11
Recommended in case of risk of direct End of service life indicator > IEC 61643-11
impact of lightning strikes End of service life indication for internal
Thanks to an admitted impulse current (Iimp) of components.
15 kA (surge 10/350 s), it is suitable for use Remote signalling
on main switchboards. The remote plug-in signalling contact allows
Varistor / spark-gaps technology alarm report to a supervision station.
This technology ensures an optimum Thermal disconnector
OQNSDBSHNMKDUDKKNVUNKS@FD4O
J5 The built-in disconnection device ensures
as well as an improved type 1/type 2 there is no damage on the installation in case
coordination. of end of service life.
Applications
q Main switchboard or main distribution panel of a
building, equipped with electronic devices (multi-
function measurement devices, PLC, etc.) with
presence of lightning conductors or protection Lightning
through meshed cages. conductor
q Main switchboard equipped with electronics
in buildings subjected to high level risk of
lightning strikes such as classified installations,
installations located in areas prone to high
density of lightning strikes, high-rise buildings.
q Main switchboard equipped with PLC, BMS G4
0-FE
modems...
q High-rise buildings safety main switchboard.
SURGYS
G40-FE
q Lift machinery unit located in the higher part of
sgys_017_d_1_gb_cat
the building.
q Safety inverter units.
q Main switchboard or remote sites containing
electronics.
PLC
DIRIS
sgys_052x_b_2_cat
q Protection in common mode.
q End of service life indicator. 1
q Remote signalling contact.
q Absence of follow current.
q Fuse combination switch recommended: 2 3
FUSERBLOC (see page 126).
Characteristics
Network Remote signalling contact
Network type 5 " Number of contacts per pole 1
Neutral systems TT-TN Contact type inverter
Nominal voltage Un 5 " AC making capacity 3A
Maximum voltage Uc 5 " DC making capacity 2A
Temporary overvoltage at industrial frequency UT 5 " AC nominal voltage 5 "
Protection characteristics DC nominal voltage 5#"
Level of protection Up (NF EN 61643-11)
J5 Sustained current 2A
Maximum discharge current (1 shock 8/20 s) Imax 40 kA Connection type plug-in screw terminal
Nominal discharge current (15 shocks 8/20 s) In 20 kA Max. cross-section of terminal
1.5 mm2
Residual voltage atimp 5 connections
Impulse current (1 shock 10/350 s) Iimp 15 kA Operating conditions
Mode of protection common Operating temperature -40 +85 C
Associated characteristics Storage temperature -40 +85 C
Residual current Ic < 10 A
(1) Value complies with article 534.1.5.3 of standard NF C 15-100: higher ratings may however
Response time tr < 100 ns be used if reinforced continuity of service of the lightning rod branch is desired.
Follow current If none
Rated conditional short circuit current Icc 50 kA
Recommended disconnectors fuses gG 125 A(1)
Type of disconnection indicator mechanical
Number of disconnection indicators 1
Case
W D Type modular
35 Dimensions W x H x D in 2 poles 70 x 90 x 67 mm
Dimensions W x H x D in 3 poles 105 x 90 x 67 mm
Dimensions W x H x D in 4 poles 140 x 90 x 67 mm
Case degree of protection IP20
sgys_035_a_1_gb_cat
Connections
Series arrangement Parallel arrangement
L1 L1 L1 L1
L2 L2 L2 L2
L3 L3 L3 L3
N N N N
DP ( 125 A) Installation DP
LV network Installation
sgys_038_a_1_gb_cat
LV network
sgys_026_b_1_gb_cat
L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N L/N
T T
References
SURGYS G40-FE
No. of poles Number of side-by-side modules Reference
2 2 4981 0420
3 3 4981 0430
4 4 4981 0440
> Industry.
protection
Advantages
Monobloc base with plug-in module Remote signalling
Customised solutions
The SURGYS is supplied complete and ready The remote plug-in signalling contact allows
for installation. Its Monobloc base is fitted with alarm report to a supervision station. > Specific shock and vibration
replaceable plug-in modules which, at the end treatment + tropicalisation
of their service life, can be easily and quickly End of service life indicator (type W): please consult us.
replaced without having to disconnect the End of service life indication for internal
Monobloc base. components.
Applications
q Main power control switchboard.
q Main safety switchboard.
q Main switchboard to high power inverters.
q Distribution boards of remote sites.
q Protection of electrotechnical equipment
such as motors, switching devices, control
devices...
SURGYS
G70
sgys_077_a_1_x_cat
SURGYS SURGYS
D40 E10
sgys_027_b_1_gb_cat
L L L N (fuses)
14
11
12
3
Characteristics
Network Remote signalling contact
Network type 230 / 400 VAC Contact type inverter
Neutral systems TT-TN-IT AC making capacity 0.5 A
Nominal voltage Un 400 VAC DC making capacity 2A
Maximum voltage Uc 400 VAC AC nominal voltage 250 VAC
Temporary overvoltage at industrial frequency UT 400 VAC DC nominal voltage 30 VDC
Protection characteristics Sustained current 2A
Level of protection Up 1.8 kV Connection type through screw block
Maximum discharge current (1 shock 8/20 s) Imax 70 kA Max. cross-section of terminal connections 1.5 mm2
Nominal discharge current (15 shocks 8/20 s) In 30 kA Operating conditions
Mode of protection common Operating temperature -40 +85 C
Associated characteristics Storage temperature -40 +85 C
Residual current Ic < 1 mA (1) Value complies with article 534.1.5.3 of standard NF C 15100: higher ratings may
Response time tr < 25 ns however be used if reinforced continuity of service of the lightning rod branch is desired.
Follow current If none
Rated conditional short circuit current Icc 25 kA
Recommended disconnectors fuses gG 100 A(1)
Type of disconnection indicator mechanical
Number of disconnection indicators 2
Case
D
Type monobloc design
2P dimensions W x H x D 36 x 90 x 67 mm
L L L N 3P dimensions W x H x D 54 x 90 x 67 mm
Dimensions W x H x D in 4 poles 72 x 90 x 67 mm
Case degree of protection IP20
H
W 44
60.8
References
SURGYS G70
No. of poles Number of side-by-side modules Reference
2 2 4982 1720
3 3 4982 1730
4 4 4982 1740
Description of accessories Reference
Spare plug-in module m-G70 4982 0719
> Industry.
protection
> Infrastructure.
Electronic
Strong points
Applications
q Power distribution unit (downstream of a main
switchboard).
q Autonomous power supply units such as
generator sets, medium power UPS.
q Machine equipment unit.
SURGYS
G70
sgys_077_a_1_x_cat
SURGYS SURGYS
D40 E10
Level of protection Up
5 (MC/MD)
Maximum discharge current (1 shock 8/20 s) Imax 40 kA
Nominal discharge current (15 shocks 8/20 s) In 20 kA
Mode of protection common and differential
Associated characteristics
3 Residual current Ic < 1 mA
Response time tr < 25 ns
Follow current If none
Rated conditional short circuit current Icc 25 kA
Recommended disconnectors fuses gG 50 A(1)
Type of disconnection indicator mechanical
Number of disconnection indicators 1
Case Remote signalling contact
D Contact type inverter
AC making capacity 0.5 A
DC making capacity 2A
AC nominal voltage 250 VAC
L L L N DC nominal voltage 30 VDC
Sustained current 2A
Connection type screw terminal block
Max. cross-section of terminal connections 1.5 mm2
H
Operating conditions
Operating temperature -40 +85 C
Storage temperature -40 +85 C
(1) Value complies with article 534.1.5.3 of standard NF C 15100: higher ratings may however
be used if reinforced continuity of service of the lightning rod branch is desired.
sgys_012_f_1_gb_cat
10.6
W 44
60.8
Connection
Type monobloc design L1
Dimensions W x H x D in 2 poles 36 x 90 x 67 mm L2
L3
Dimensions W x H x D in 3 poles 54 x 90 x 67 mm N
Dimensions W x H x D in 4 poles 72 x 90 x 67 mm LV network Installation
DP
Case degree of protection IP20
Terminal block degree of protection IP20
T : Telesignalling
Case material polycarbonate UL94-V0 DP : Protection device
L L L N
Earth connection cross-section 4 25 mm2 (Fuses)
Network connection cross-section 4 25 mm2 D40 D40 D40 D40 T
sgys_072_a_1_fr_cat
12
11
14
14
11
12
References
SURGYS D40
No. of poles Neutral systems Mode of protection Number of side-by-side modules Reference
2 TT, TN, IT MC(1) 2 4982 1422
3 TT, TN, IT MC(1) 3 4982 1432
4 TT, TN, IT MC(1) 4 4982 1442
2 TT, TN MC(1) / MD(2) 2 4982 1424
4 TT, TN MC(1) / MD(2) 4 4982 1444
Description of accessories Mode of protection Reference
Spare plug-in module m-D40 MC(1) 4982 0419
Spare plug-in module m-D40 MC(1) / MD(2) 4982 0418
(1) Common mode. (2) Differential mode.
> Industry.
protection
> Infrastructure.
Electronic
Strong points
Advantages
Monobloc base with plug-in modules Remote signalling
The SURGYS is supplied complete and ready The remote plug-in signalling contact allows
for installation. Its Monobloc base is fitted with alarm report to a supervision station.
replaceable plug-in modules which, at the end
of their service life, can be easily and quickly
replaced without having to disconnect the
Monobloc base.
Applications
SURGYS
G70
SURGYS SURGYS
D40 E10
sgys_042_e_1_x_cat
PC PC PC
sgys_070x_a_1_cat
2 Maximum voltage Uc 400 VAC (MC) 255 VAC (MC/MD)
5. Plug-in module
Temporary overvoltage at
400 VAC
industrial frequency UT
5
Protection characteristics
1.3 kV (MC) 1.5
Level of protection (MC/MD) Up(1)
/ 0.9 kV (MC/MD)
Maximum discharge current
10 kA
3
(1 shock 8/20 s) Imax
Nominal discharge current
Cases 5 kA
(15 shocks 8/20 s) In
D Voltage Uoc 10 kV
Mode of protection common and differential
Associated characteristics
L L L N
Residual current Ic < 1 mA
sgys_043_d_1_gb_cat Response time tr < 25 ns
Follow current If none
H
Connection
AC version DC version
Common mode (MC) and differential mode (MC/MD) protection
L1 L+
L2 L
L3
N
LV network Installation
DP
L/N
T : Remote signalling
DP : Protection device
sgys_071_a_1_gb_cat
sgys_041_a_1_x_cat
L L L N
(Fuses)
E10
E10 E10 E10 E10 T
12
11
14
14
11
12
References
Applications AC SURGYS E10-AC Applications DC SURGYS E10-DC
No. of poles Neutral systems Mode of protection Reference No. of poles Network voltage Reference
2 TT, TN, IT MC(1) 4983 1125 2 12 VDC 4983 2601
3 TT, TN, IT MC(1) 4983 1135 2 24 VDC 4983 2602
4 TT, TN, IT MC(1) 4983 1145 2 48 VDC 4983 2604
2 TT, TN MC(1) / MD(2) 4983 1126 Spare module for DC application SURGYS E10-DC
4 TT, TN MC(1) / MD(2) 4983 1146 Network voltage Reference
Spare plug-in module for AC application SURGYS E10-AC 12 VDC 4983 9901
Mode of protection Reference 24 VDC 4983 9902
MC(1) / MD(2) 4983 0198 48 VDC 4983 9904
MC(1) 4983 0199 (1) Differential mode. (2) Common mode.
> Manufacturing.
Electronic
sgys_093_a
Strong points
SURGYS RS-3 SURGYS mA-3x2
> Versions 1 pair or 2 pairs
(model x2).
> Plug-in modules.
Function > End of service life indicator.
For protection against transient overvoltages of equipment connected to telecommunication and > Direct earthing.
data transmission networks the SURGYS range includes 3 surge arrester models: > Common mode / differential
mode protection.
q SURGYS RS-3.
q SURGYS mA-3. Conformity to standards
q SURGYS TEL-3.
> NF EN 61643-21
> IEC 61643-21
Advantages
NEW Direct earthing
Versions 1 pair or 2 pairs (model x2). Earth bonding is made using a DIN rail
Ultra-compact design if multi-pair protection fixing clip.
is needed.
Common mode / differential mode
NEW protection
Plug-in modules The differential mode offers an improved
Rapid maintenance for end of service life protection efficiency.
modules.
Applications
SURGYS RS-3 SURGYS mA-3 SURGYS TEL-3
q Protection of the q Field bus: q Analogue telephone line:
RS422/RS485 connections. - Profibus (DP, PA, FMS), - modem,
q Digital telephone line T2. - Fieldbus (H1, H2), - automatic switch,
q ETHERNET connection (10 baseT). - LONworks, - telephone alarm,
- Interbus, - DSL.
q Measurement loops, measurement acquisition
cards:
- current loops 0 / 4-20 mA,
- analog signals 0 to 10 V.
q Regulation, control loops.
q RS232 connections.
q Numeris network (RNIS-T0).
q Specialised telephone connections.
Sensor
Phone line
Communicating
product Line 0 - 20 mA RTC line T2 line
SURGYS
RS-3
SURGYS
mA-3
sgys_023_g_1_gb_cat
sgys_024_e_1_gb_cat
sgys_022_f_1_gb_cat
SURGYS SURGYS
TEL-3 RS-3
SURGYS
RS-3
Connecting
g Modem Modem
bus Measuring
transducer
PC
Front panel
1. Plug-in module
2. Mounting on DIN rail ensuring earthing
4
3. Connection 1 pair
4. Connection 2 pairs
3 3
2 2
sgys_093x_a_1
1 1
Characteristics
Case
Version 1 pair
65
13
Line
Type modular
Dimensions W x H x D 13 x 90 x 65 mm
1 2 Case degree of protection IP20
Terminal block degree of protection IP20
sgys_082_a_1_gb_cat
1 2
Load
Version 2 pairs
68
18
Line
1 3 5
Type modular
7 9 11 Dimensions W x H x D 18 x 90 x 68 mm
sgys_080_a_1_cat
2 4 6
Load
Connections
Version 1 pair Version 2 pairs
Network Network
L1 L2 2L1 1L2 1L2 2L2
Shield
Shield
Earth Earth
sgys_032_ h_1_gb_cat
sgys_081_a_1_gb_cat
Shield
Shield
References
Versions 1 pair Versions 2 pairs
SURGYS RS-3 mA-3 TEL-3 RS-3x2 mA-3x2 TEL-3x2
Reference Reference Reference Reference Reference Reference
Protection of high speed data and telephone networks 4986 3020 4986 3021
Protection of measurement-control-regulation circuits and field bus 4987 3420 4987 3421
Protection of telephone networks 4985 3170 4985 3171
Enclosures Busbar
Enclosures in polyester with Steel units Enclosures For dimensioning
sealed cover
Rigid copper
CADRYS
bars
CADRYS DELTA
COMBIESTER enclosures
p. 558
modular
p. 550 p. 551 p. 552
Flexible
copper bars
p. 558
new
Distribution Insulated
copper braids
High power
p. 560
Cable clamps
and cage Distribution
Terminals terminals blocks
p. 582 p. 584 p. 586 Busbar
supports
Mid power p. 562
Distribution
blocks Mounting accessories
p. 586
Mounting
rails and
proles
p. 592
All the components to facilitate the use of your Did you know?
Enclosures
Enclosure
Busbar
Busbar supports
Copper bars
Copper braids
Thermal
control
Air conditioning
Ventilation
systems
Heating systems
vign_054_c
combi_003_a_1_cat
combi_001_a_1_cat
Strong points
> Safety.
> Extended range.
> Protection degree:
COMBIESTER COMBIESTER IP65 and IK9.
with transparent cover constructible version
> Flexibility: assembling.
Available on request
kdrys_299_a_1_cat
Strong points
CADRYS ST with solid door
CADRYS SP with transparent door > Safety.
> Wide range.
Conformity to standards
Available on request
> Monobloc
CADRYS cabinet
for automation
CADRYS SH with solid door equipment
and electrical
distribution.
Function
CADRYS wall-mounted enclosures are General characteristics
intended to include automation or control q Double bar locking.
equipment. q Bottom closing plate with pressed neoprene
seal,
q Concealed hinges.
q Earthing screw.
Available on request
q Door profiles perforated every 25 mm.
q Casing and solid door, polyester epoxy > Special paint,
paint RAL 7035.
> Specific cutouts (enclosures,
q Reversible doors. plates...)
> Specific dimensions.
> Enclosures with top and
Advantages bottom openings.
Safety Wide range
q These enclosures ensure electrical safety A wide range is available to meet any
with a degree of protection IP55 (casing requirement:
edge in channel form, robot positioned q 22 models for the SI range.
polyurethane seal). q 36 models for the ST range.
q A folded and welded casing provides an q 22 models for the SH range.
improved rigidity and a high resistance q 17 models for the SP range.
to chemicals (carbon steel FE 40 +
70 polyester epoxy paint; stainless steel
304 L brushed and polished).
Strong points
kdrys_460_a_1_cat
kdrys_418_b_1_cat
CADRYS DELTA
Conformity to standards
Function
> IEC 60529
CADRYS DELTA enclosures are modular They can be placed side by side, back to
steel enclosures. They are intended to include back and/or side to back. They can be > IEC 61439-2
automation or electrical equipment. delivered pre-assembled or, on request, in kit > NF C 15-100
form. > NF C 20010
> IEC 62208
Advantages
q Thanks to its galvanised sheet structure, q CADRYS DELTA are provided as standard
&$'5<6b'(/7$ ensures the role with a reversible hing system for easy
of a FARADAY cage, thus reducing access.
electromagnetic interferences and ensuring
correct earth bonding. q Specific configurations can be proposed
as per customer's specifications. (colour,
q CADRYS DELTA enclosures are provided dimension, factory pre-assembling, etc.).
with 100 mm reinforced handling feet which
can be fitted with a bottom panel.
q Single-wing CADRYS DELTA enclosures
have left/right reversible doors requiring no
tools.
1
kdrys_471_b_2_x_cat
kdrys_509_a_1_x_cat
kdrys_510_a_1_x_cat
kdrys_511_a_1_x_cat
kdrys_512_a_1_x_cat
kdrys_513_a_1_x_cat
Coupling side by side Coupling back to back Coupling back to back Juxtaposition in an L Juxtaposition in an L Juxtaposition in an L with
+ side doors with busbar housings front and rear doors
External options
Tripod Busbar housing
The frame elements are assembled q Fits in between the top panel
kdrys_426_a_1_cat
by screwing onto a tripod. and the top of the cubicle.
q Takes bars up to 160 mm high.
kdrys_304_a_1_cat
Side panels
q Thanks to a special anchoring
system, the side and back panels
are easily mounted.
Back panel q The side panel can be replaced
The back panel can by a door without the addition
be replaced by a door or removal of any accessories.
without the addition
or removal of any
accessories.
kdrys_432_a_2_cat
kdrys_433_a_1_cat
kdrys_428_a_1_cat
Door
The door can be reversed without
removing the handle or hinges
in 3 easy steps:
1. Remove the hinge pins. Handle
2. Reversing of the door. q An ergonomic automatic locking
3. Replace the hinge pins. handle that does not require the use
of a key.
This handle cannot be locked with
the door open (CNOMO system).
kdrys_429_a_1_cat
kdrys_430_a_1_cat
kdrys_431_a_1_cat
1 2 3
Bases
q The bases have 4 removable sides
made of folded 1.2 mm steel.
The angle pieces are 3 mm steel
reinforced by welding. Juxtaposition
q They are designed to allow several The juxtaposition of cubicles side or
bases to be stacked so as to back to back is achieved using a kit that
obtain the height required. guarantees IP55 sealing.
kdrys_ 407_a_1-_cat
kdrys_406_a_1_cat
Internal options
kdrys_289_a_1_cat
kdrys_434_a_1_cat
kdrys_435_a_1_cat
kdrys_436_a_1_cat
kdrys_209_a
Solid plate Notched mounting profiles
A system of slides and clips facilitate the q These facilitate the positioning
positioning of the plates and holds them in of the nuts and provide support
place during assembly. during assembly.
q These provide good slip
resistance, particularly in the
event of vibration during
kdrys_314 _b_2_cat
transport.
kdrys_438_a_1_cat
kdrys_437_a-1_cat
Internal door
q This allows the mounting of control
auxiliaries and measuring devices
Nuts
protected by a solid
The clip-on nuts fit onto the mounting or transparent front
profiles and perforated plates whilst also door.
providing earthing. q It is fixed onto the
Kdrys_440_a_1_cat
pitch of 25 mm.
Structural profiles
q In 1.75 mm steel double perforated
every 25 mm so as to allow made-
to-measure dimensions.
q These profiles allow the direct
mounting of SOCOMEC SBC 10
Gland plate and 20 bar supports.
q The closing plate is fixed in place by a knurled nut.
q It is tightened manually with no tools required.
Kdrys_282_a_1_cat
Kdrys_281_a_1_cat
Kdrys_441_a_1_cat
Kdrys_442_a_1_cat
Edgewise mounting
Number of bars per phase
Bar section
l x e (mm) I II III IIII
20 x 4 240 430 600 750
15 x 5 220 390 540 650
barre_001_a_1_cat
References
Solid bars
L = 1750 L = 2900 L = 5800
To be ordered by To be ordered by To be ordered in
multiple1 bar multiple1 bar multiples of
5 or 10 bars
l x e (mm) Weight (kg/ml) Reference Reference Reference
20 x 4 0.71 4510 2004 4513 2004 4514 2004(1)
25 x 5 1.11 4510 2505 4513 2505 4514 2505(1) l
32 x 5 1.42 4510 3205 4513 3205 4514 3205(1)
40 x 5 1.78 4510 4005 4513 4005 4514 4005(1)
50 x 5 2.22 4510 5005 4513 5005 4514 5005(1)
63 x 5 2.80 4510 6305 4513 6305 4514 6305(1)
barre_002_a_1_x_cat
80 x 5 3.56 4510 8005 4513 8005 4514 8005(2)
100 x 5 4.45 4510 9005 4513 9005 4514 9005(2) L
125 x 5 5.56 4510 9205 4513 9205 4514 9205(2)
30 x 10 2.67 4510 3010 4513 3010 4514 3010(2)
50 x 10 4.45 4510 5010 4513 5010 4514 5010(2) e
60 x 10 5.33 4510 6010 4513 6010 4514 9205(2)
80 x 10 7.11 4510 8010 4513 8010 4514 8010(2)
100 x 10 8.89 4510 9010 4513 9010 4514 9010(2)
125 x 10 11.11 4510 9210 4513 9210 4514 9210(2) (1) To be ordered by multiple 10 bars
160 x 10 14.22 4510 9610 4513 9610 4514 9610(2) (2) To be ordered by multiple 5 bars
Pre-punched bars
25
0 = l=
To be ordered
l x e (mm) W (mm) Weight (kg/ml) Nb de rows in multiples of Reference 1 =
4511 2505 5 25
12.
25 x 5 1750 1.11 1 5
50 x 5 1750 2.22 2 5 4511 5005
63 x 5 1750 2.80 2 5 4511 6305 L
80 x 5 1750 3.56 2 5 4511 8005 25
e 0
1 l>
barre_003_a_1_x_cat
100 x 5 1750 4.45 2 5 4511 9005
4511 9205 5
125 x 5 1750 5.56 2 5
52
50 x 10 1750 4.45 2 5 4511 5010 12.
60 x 10 1750 5.33 2 5 4511 6010
80 x 10 1750 7.11 2 5 4511 8010 5
100 x 10 1750 8.89 2 5 4511 9010
12. L
Accessories
Drill-free connection accessories
Use
q Allows the drill-free connection of flexible bars or q For terminals or flexible bars with widths greater
cables onto a busbar. than 40 mm, use 2 connection accessories.
q Connection across 2 bars, 10 mm thick, placed q Secured with M10 screws, tightening torque 45Nm.
barre_020_a_1_x_cat
Strong points
Conformity to standards
Function > VDE 207 Y16
SOCOMEC insulated flexible copper bars are mainly utilised for providing the power > BS 6746
connections between series of distribution busbars and the disconnection devices within an > NF A 51-050
electrical panel.
> VDE 207 YM4
The insulated layered copper allows the flexible copper bar to be easily formed to provide a
customised solution. > DIN 40050
Characteristics
q Width of 9 to 100 mm. Insulated flexible busbar
q Copper layer thickness from 0.8 to 1 mm. q Operating-temperature range:
q Length of 2 m. from -40 C to +105 C.
q Maximum operating voltage:
Conductor 1000 VAC / 1500 VDC.
q Layers of electrolytic copper Cu/ETP, q Alternating voltage withstand
final annealing state. (10 minute test):
ADSVDDMBNQD@MCHMRTK@SHNM
J5
Insulator - between two insulating elements in
contact: 33 kV,
q High temperature co-extruded vinyl
compound on the copper strips - Conductivity: 100 IACS,
(insulation thickness: 1.5 to 2 mm). - HV < 50,
q Self-extinguisher: NFC 32200 and UL 94 V0. - Resistance to traction Rm > 200 N/cm,
q Continuous temperature withstand: 105 C. 2SQDSBGADENQDAQD@J
q Shore hardness A: 89 +/- 2. 1DRHRSHUHSX
LHBQNBL@S"
q ,NCTKDDKNMF@SHNM,O@
q 1DRHRS@MBDSNDKNMF@SHNMLHMH
q Breaking stress: 20 Mpa.
q 3Q@MRUDQR@KUNKTLDQDRHRSHUHSX
q .WXFDMHMCDW
q Scratch and tear resistant.
References Implementation
(1)
/DQLHRRHAKD@LODQ@FDENQ3"
To be ordered
400 400
l x N x e (mm) L (mm) " " " in multiples of Reference
amc_017_a_1_x_cat
x x x
9 x 2 x 0.8 2000 113 129 143 4 4518 0902
9 x 3 x 0.8 2000 140 178 4 4518 0903
9 x 4 x 0.8 2000 188 209 4 4518 0904
9 x 5 x 0.8 2000 187 214 238 4 4518 0905
WW 2000 208 238 4 4518 0906
13 x 3 x 0.5 2000 142 180 4 4518 1303
13 x 4 x 0.5 2000 189 210 4 4518 1304
13 x 5 x 0.5 2000 213 237 4 4518 1305
WW
2000 235 4 4518 1306
15.5 x 2 x 0.8 2000 191 212 4 4518 1502 Flexible bars should be mounted on insulated
15.5 x 3 x 0.8 2000 207 237 4 4518 1503 supports with a maximum distance of
15.5 x 4 x 0.8 2000 242 277 308 4 4518 1504 LL
!@QRRGNTKC@KRNADGDKCSNFDSGDQ
WW
2000 304 347 4 4518 1506 with straps, as shown in the above diagram.
15.5 x 8 x 0.8 2000 358 409 455 4 4518 1508 The distance between successive straps
15.5 x 10 x 0.8 2000 408 519 4 4518 1510 depends on the electro-dynamic constraints
20 x 2 x 1 2000 228 290 4 4518 2002
in the event of a short-circuit. The table below
20 x 3 x 1 2000 283 324 4 4518 2003
20 x 4 x 1 2000 331 378 421 4 4518 2004 gives the recommended distances between
20 x 5 x 1 2000 374 428 4 4518 2005 straps.
WW 2000 415 474 527 4 4518 2006
20 x 8 x 1 2000 488 558 4 4518 2008 Icc max.
20 x 10 x 1 2000 705 4 4518 2010 (kA rms) Distance x between straps (mm)(1)
24 x 2 x 1 2000 301 335 4 4518 2402 20 350
24 x 3 x 1 2000 373 414 4 4518 2403 25 200
24 x 4 x 1 2000 380 435 483 4 4518 2404
35 100
24 x 5 x 1 2000 429 491 4 4518 2405
WW 2000 475 542 4 4518 2406 45 70
24 x 8 x 1 2000 557 708 4 4518 2408 (1) 9 mm straps, load 80 kg.
24 x 10 x 1 2000 722 803 4 4518 2410
32 x 2 x 1 2000 331 379 421 4 4518 3202
32 x 3 x 1 2000 409 520 4 4518 3203
32 x 4 x 1 2000 544 4 4518 3204
32 x 5 x 1 2000 4 4518 3205
WW 2000 591 751 4 4518 3206
32 x 8 x 1 2000 787 4 4518 3208
32 x 10 x 1 2000 777 887 987(1) 4 4518 3210
40 x 2 x 1 2000 398 455 2 4518 4002
40 x 3 x 1 2000 490 2 4518 4003
40 x 4 x 1 2000 723 2 4518 4004
40 x 5 x 1 2000 730 812 2 4518 4005
WW 2000 703 803 893 2 4518 4006
40 x 8 x 1 2000 815 932 2 4518 4008
40 x 10 x 1 2000 915 1045 2 4518 4010
50 x 3 x 1 2000 589 749 2 4518 5003
50 x 4 x 1 2000 780 2 4518 5004
50 x 5 x 1 2000 873 971 2 4518 5005
WW 2000 838 957 2 4518 5006
50 x 8 x 1 2000 1105 1229 2 4518 5008
50 x 10 x 1 2000 1080 1234 1373 2 4518 5010
WW 2000 715 908 2 4518 6303
WW 2000 825 943 1048 2 4518 6304
WW 2000 921 1052 1171 2 4518 6305
WW 2000 1041 1187 1324 2 4518 6306
WW 2000 1157 1321 1470 2 4518 6308
WW 2000 2 4518 6310
80 x 3 x 1 2000 874 998 1110 2 4518 8003
80 x 4 x 1 2000 1149 1278 2 4518 8004
80 x 5 x 1 2000 1119 1279 1422 2 4518 8005
WW 2000 1220 1393 1550 2 4518 8006
80 x 8 x 1 2000 1393 1592 1771 2 4518 8008
80 x 10 x 1 2000 1543 2 4518 8010
100 x 4 x 1 2000 1211 1383 1538 2 4518 9004
100 x 5 x 1 2000 1343 1534 1707 2 4518 9005
WW 2000 1855 2 4518 9006
100 x 8 x 1 2000 1897 2110 2 4518 9008
100 x 10 x 1 2000 1833 2094 2329 2 4518 9010
100 x 12 x 1 2000 1993 2277 2531 2 4518 9012
(1) For ambient air temperature of 40 C I: width of bare busbar in mm.
Important: max. busbar temperature = 105 C. N: number of copper layers.
L: length of bar in metres. e: copper layer thickness in mm.
new
> Electrical distribution.
Enclosures
Strong points
Conformity to standards
Advantages
Easy to install Compatibility
q Compact and flexible. q With SOCOMEC devices.
q Length and orientation are easily adapted. q With most circuit-breakers on the market.
q Pre-mounted connection terminals reduces
installation time.
References
Connections in parallel
Facteur de correction Admissible current at an
Dimensions ambient temperature of
Rated current (no derating) X Nominal
A e L Fixing rating
2 x rated current x 0.8 Width Thickness Length 1 2 centres 35 C 45 C 55 C
(mm) (mm) (mm) (mm) (mm) (mm) (A) (A) (A) Reference
WQ@SDCBTQQDMSW
20
220
200 180 160 140 4516 1620
20
270
180 160 140 4516 1625
20
320
300 180 160 140 4516 1630
20
370
180 160 140 4516 1635
20
420
400 180 160 140 4516 1640
20
180 160 140 4516 1650
#HLDMRHNMR
X Nominal
rating 45 C A e B1 B2 C1 C2 1 2 f h
B1 B2 (A) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
160 20
30 8 12
22
h
A
20 3 30 8 12
22
1 2 400 30 10 12
7 27
tress_001_a_1_x_cat
C1 C2 630 30 10 30 12 12
12 32
f
e
sb_077_a_1_cat
sb_103_a_1_cat
Insulators
Conformity to standards
Selection guide
Edgewise mounting
Icc up to 50 kA
SB C 20 SB C 30
p. 566 p. 568
SB C 10 p. 564 SB C 10 p. 564
100 A 400 A 500 A 630 A 1000 A 1600 A 2500 A 4000 A 5800 A 7000 A
Nominal current n
SB C ER
p. 570
Icc up to 40 kA
SB C ER Power
p. 571
Icc up to 80 kA
Flat mounting
Unipolar busbar supports
Icc up
to 80 kA
100 A 400 A 500 A 630 A 1000 A 1600 A 2500 A 4000 A 5800 A 7000 A
Nominal current n
SB 7500 p. 573
Icc up to 50 kA SB P 30 p. 574
Icc up to 80 kA
Multipolar busbar supports
Other supports
Unipolar busbar supports
Icc up to 50 kA
(1)
100 A 400 A 500 A 630 A 1000 A 1600 A 2500 A 4000 A 5800 A 7000 A
Icc up to 40 kA
sb_061_b_2_cat
3 1000 2 x 5 / 1 x 10 190 50 1 5024 6310
3 1000 2 x 5 / 1 x 10 190 60 1 5024 6312
3 1000 2 x 5 / 1 x 10 190 63 1 5024 6313
3 1000 2 x 5 / 1 x 10 220 80 1 5024 6317
4 1000 2 x 5 / 1 x 10 160 25 1 5024 6504
4 1000 2 x 5 / 1 x 10 160 40 1 5024 6509
4 1000 2 x 5 / 1 x 10 190 50 1 5024 6510
4 1000 2 x 5 / 1 x 10 190 60 1 5024 6512
4 1000 2 x 5 / 1 x 10 190 63 1 5024 6513
4 1000 2 x 5 / 1 x 10 220 80 1 5024 6517
4 1000 2 x 5 / 1 x 10 220 100 1 5024 6518
Bar holder
Pack
Number of bars max x bar thickness (mm) No. of poles qty Reference
2 x 5 / 1 x 10 3 1 5024 9031(1)
2 x 5 / 1 x 10 4 1 5024 9041(1)
(1) Bar holder: 1 support without insert + 2 screws M8 + 2 nuts.
1 or 2 bars of 10 mm
sb_174_a_2_cat
4 1000 1 x 10 / 2 x 10 160 25 1 5024 6604
4 1000 1 x 10 / 2 x 10 160 40 1 5024 6609
4 1000 1 x 10 / 2 x 10 190 50 1 5024 6610
4 1000 1 x 10 / 2 x 10 190 60 1 5024 6612
4 1000 1 x 10 / 2 x 10 190 63 1 5024 6613
4 1000 1 x 10 / 2 x 10 220 80 1 5024 6617
4 1000 1 x 10 / 2 x 10 220 100 1 5024 6618
Bar holder
Pack
Number of bars max x bar thickness (mm) No. of poles qty Reference
1 x 10 / 2 x 10 3 1 5024 9034(1)
1 x 10 / 2 x 10 4 1 5024 9044(1)
(1) Bar holder: 1 support without insert + 2 screws M8 + 2 nuts.
Accessories
sb_094_a_1_x_cat
sb_177_a_1_x_cat
Characteristics
Characteristics of 3 and 4 poles with 5 mm for SB C 10
Lm
Max. L (distance between centres of supports in mm) for ax.
peak Isc 15 kA 24 kA 48 kA 63 kA 82 kA 114 kA
rms Isc 9 kA 12 kA 23 kA 30 kA 39 kA 52 kA
Bar x no. d (mm) Iz (A)(1)
25 x 5 x 1 775 475 225 175 140 100 60 330
25 x 5 x 2 675 425 200 160 125 60 590
sb_021_b_1_gb_cat
40 x 5 x 1 1000 625 300 225 175 130 60 500
40 x 5 x 2 950 575 275 225 170 125 60 850
50 x 5 x 1 1000 700 350 250 200 130 60 600
50 x 5 x 2 1000 675 325 250 200 145 60 1050 d
60 x 5 x 1 1000 775 375 300 225 130 60 700
60 x 5 x 2 1000 775 375 300 225 165 60 1200 Adhering to the maximum distances between two
63 x 5 x 1 1000 800 400 300 225 130 60 700 supports ensures the busbar supports are able to
63 x 5 x 2 1000 800 400 300 225 170 60 1250 withstand the given short circuit current values. At
these values, deformation of the copper bars may
80 x 5 x 1 1000 950 475 350 225 125 60 900
occur. These deformations are permitted by standard
80 x 5 x 2 1000 975 475 375 275 200 60 1550
IEC 60439-1 as long as they adhere to the insulation
100 x 5 x 1 1000 1000 550 400 225 125 60 1100 distances.
100 x 5 x 2 1000 1000 575 425 325 225 60 1900
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us.
sb_054_b_1_x_cat
Max. L (distance between centres of supports in mm) for
peak Isc 15 kA 24 kA 48 kA 63 kA 82 kA 114 kA
rms Isc 9 kA 12 kA 23 kA 30 kA 39 kA 52 kA
Bar x no. d (mm) Iz (A)(1)
25 x 10 x 1 1000 1000 500 375 275 200 65 Mounting of one or two bars per pole
25 x 10 x 2 1000 1000 525 400 300 200 90 850
40 x 10 x 1 1000 1000 650 475 375 250 65 700
40 x 10 x 2 1000 1000 700 525 400 275 90 1250
50 x 10 x 1 1000 1000 725 550 425 300 65 850
50 x 10 x 2 1000 1000 800 600 475 325 90 1550
60 x 10 x 1 1000 1000 800 625 475 325 65 1000
sb_045_b_1_x_cat
60 x 10 x 2 1000 1000 900 675 525 350 90 1800
63 x 10 x 1 1000 1000 825 625 475 350 65 1050
63 x 10 x 2 1000 1000 925 700 550 350 90 1850
80 x 10 x 1 1000 1000 975 725 550 400 65 1300
80 x 10 x 2 1000 1000 1000 850 650 350 90 2300
100 x 10 x 1 1000 1000 1000 850 650 400 65 1550
100 x 10 x 2 1000 1000 1000 975 675 350 90 2750
Bars joined by reversing a support
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us.
Dimensions
2 bars of 5 mm or 1 bar of 10 mm 1 or 2 bars of 10 mm
R+66
sb_187_b_1_x_cat
R+66
R
R+66
B
B
R
B
R
75 90
274 65
274 374
References
No. of Insulation No. of Thickness of B R bar height Pack
poles voltage (VAC) bars the bar (mm) (mm) (mm) qty Reference
3 1000 14 5 190 50 1 5024 8310
3 1000 14 5 190 60 1 5024 8312
3 1000 14 5 190 63 1 5024 8313
3 1000 14 5 220 80 1 5024 8317
sb_077_a_1_cat
3 1000 14 5 220 100 1 5024 8318
3 1000 14 5 245 120 1 5024 8320
3 1000 14 5 245 125 1 5024 8321
3 1000 14 5 280 160 1 5024 8324
3 1000 12 10 190 50 1 5024 7310
3 1000 12 10 190 60 1 5024 7312
3 1000 12 10 190 63 1 5024 7313
3 1000 12 10 220 80 1 5024 7317
3 1000 12 10 220 100 1 5024 7318
3 1000 12 10 245 120 1 5024 7320
3 1000 12 10 245 125 1 5024 7321
3 1000 12 10 280 160 1 5024 7324
4 1000 14 5 190 50 1 5024 8410
4 1000 14 5 190 60 1 5024 8412
4 1000 14 5 190 63 1 5024 8413
4 1000 14 5 220 80 1 5024 8417
4 1000 14 5 220 100 1 5024 8418 Our advantages
4 1000 14 5 245 120 1 5024 8420
4 1000 14 5 245 125 1 5024 8421
4 1000 14 5 280 160 1 5024 8424
> The details which make a
4 1000 12 10 190 50 1 5024 7410 difference: SB C 20 busbar
4 1000 12 10 190 60 1 5024 7412 supports have threaded holes
4 1000 12 10 190 63 1 5024 7413 which allow a protective
4 1000 12 10 220 80 1 5024 7417 screen to be attached.
4 1000 12 10 220 100 1 5024 7418
4 1000 12 10 245 120 1 5024 7420 The supports are put in place
4 1000 12 10 245 125 1 5024 7421 using threaded rods and M8
4 1000 12 10 280 160 1 5024 7424 nuts.
Bar holder
To be ordered in
No. of poles multiples of Reference
3 1 5024 9032(1)
4 1 5024 9042(1)
(1) Bar holder: 1 support without insert + 2 screws M8 + 2 nuts.
Accessories
sb_093_a_1_x_cat
sb_177_a_1_x_cat
Bar holder
Installation corner piece for
bar holder
Characteristics
Characteristics of 3 and 4 poles with 5 mm for SB C 20
Lm
Max. L (distance between centres of supports in mm) for ax.
peak Isc 63 kA 82 kA 114 kA 152 kA 165 kA 187 kA 220 kA 264 kA
sb_021_b_1_x_cat
rms Isc 30 kA 39 kA 52 kA 69 kA 75 kA 85 kA 100 kA 120 kA
d
Bar x no. (mm) Iz (A)(1)
50 x 5 x 1 625 475 350 250 225 200 175 150 90 600
50 x 5 x 2 525 400 300 225 200 175 155 130 90 1050
50 x 5 x 3 600 450 325 250 225 200 175 145 90 1450
50 x 5 x 4 675 525 375 275 250 225 175 160 90 1850
d
60 x 5 x 1 675 525 375 275 250 225 200 165 90 700
60 x 5 x 2 600 450 325 250 225 200 175 145 90 1200
Adhering to the maximum distances between two
60 x 5 x 3 675 525 375 275 250 225 175 165 90 1700 supports ensures the busbar supports are able to
60 x 5 x 4 750 575 400 300 275 250 200 175 90 2150 withstand the given short circuit current values. At
63 x 5 x 1 700 550 375 275 250 225 200 170 90 700 these values, deformation of the copper bars may
63 x 5 x 2 625 475 350 250 225 200 175 150 90 1250 occur. These deformations are permitted by standard
63 x 5 x 3 700 525 375 275 250 225 200 170 90 1800 IEC 60439-1 as long as they adhere to the insulation
63 x 5 x 4 775 600 425 325 275 250 200 175 90 2250 distances.
80 x 5 x 1 800 625 450 325 300 250 225 175 90 900
80 x 5 x 2 725 550 400 300 275 250 200 175 90 1550
80 x 5 x 3 800 625 450 325 300 275 225 175 90 2200
80 x 5 x 4 875 675 475 350 325 300 250 200 90 2750
100 x 5 x 1 900 700 500 375 350 300 250 200 90 1100
sb_063_a_1_x_cat
100 x 5 x 2 850 650 475 350 325 275 225 200 90 1900
100 x 5 x 3 925 700 500 375 350 300 250 200 90 2650
100 x 5 x 4 975 750 525 400 375 325 275 225 90 3350
125 x 5 x 1 1000 800 575 425 400 350 300 250 90 1300
125 x 5 x 2 975 750 550 400 375 325 275 225 90 2350
125 x 5 x 3 1000 800 575 425 400 350 300 250 90 3 250
Mounting of one to four
125 x 5 x 4 1000 825 575 425 400 350 300 250 90 4100
bars per pole
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us.
Dimensions
350 350
40 40
110 90
sb_066_c_1_x_cat
sb_067_c_1_x_cat
R + 80
R+80
B
B
R
386 386
Fixed interphase: q 4 poles: 90 mm
q 3 poles: 110 mm
References
No.
of Insulation No. of Thickness of B R bar Pack
poles voltage (VAC) bars the bar (mm) (mm) height (mm) qty Reference
3 1000 13 10 190 50 1 5024 5310
sb_173_a_2_cat
3 1000 13 10 190 60 1 5024 5312
3 1000 13 10 190 63 1 5024 5313
3 1000 13 10 190 70 1 5024 5315
3 1000 13 10 220 80 1 5024 5317
3 1000 13 10 220 100 1 5024 5318
3 1000 13 10 245 120 1 5024 5320
3 1000 13 10 245 125 1 5024 5321
3 1000 13 10 280 160 1 5024 5324
3 1000 13 10 325 200 1 5024 5325
4 1000 13 10 190 50 1 5024 5510
4 1000 13 10 190 60 1 5024 5512
4 1000 13 10 190 63 1 5024 5513
4 1000 13 10 190 70 1 5024 5515
4 1000 13 10 220 80 1 5024 5517
4 1000 13 10 220 100 1 5024 5518
4 1000 13 10 245 120 1 5024 5520
4 1000 13 10 245 125 1 5024 5521
4 1000 13 10 280 160 1 5024 5524
4 1000 13 10 325 200 1 5024 5525
Bar holder
Pack
No. of poles qty Reference
3/4 1 5024 9033(1)
(1) Bar holder: 1 support without insert + 2 screws M8 + 2 nuts.
Accessories
sb_122_b_1_x_cat
sb_180_a_1_x_cat
Characteristics
Characteristics of 3 and 4 poles with 10 mm for SB C 30 Lm
Max. L (distance between centres of supports in mm) for ax.
peak Isc 63 kA 82 kA 114 kA 152 kA 165 kA 187 kA 220 kA 264 kA
rms Isc 30 kA 39 kA 52 kA 69 kA 75 kA 85 kA 100 kA 120 kA
sb_021_b_1_x_cat
d
Bar x no. (mm) Iz (A)(1)
50 x 10 x 1 1000 1000 800 600 550 475 400 350 130 850
50 x 10 x 2 1000 900 650 475 450 400 325 275 130 1550
50 x 10 x 3 725 550 400 300 275 225 200 175 130 2150
60 x 10 x 1 1000 1000 875 650 600 525 450 375 130 1000
60 x 10 x 2 1000 1000 725 525 500 425 375 300 130 1800 d
60 x 10 x 3 825 625 450 325 300 275 225 175 130 2500
63 x 10 x 1 1000 1000 900 675 600 550 450 375 130 1050 Adhering to the maximum distances between two
supports ensures the busbar supports are able to
63 x 10 x 2 1000 1000 725 550 500 450 375 300 130 1850
withstand the given short circuit current values. At
63 x 10 x 3 850 650 450 350 325 275 225 200 130 2600 these values, deformation of the copper bars may
80 x 10 x 1 1000 1000 1000 750 675 600 500 425 130 1300 occur. These deformations are permitted by standard
80 x 10 x 2 1000 1000 825 625 575 500 425 350 130 2300 IEC 60439-1 as long as they adhere to the insulation
80 x 10 x 3 1000 750 550 400 375 325 275 225 130 3 200 distances.
100 x 10 x 1 1000 1000 1000 825 750 675 575 475 130 1550
100 x 10 x 2 1000 1000 925 675 625 550 475 400 130 2750
100 x 10 x 3 1000 900 650 475 425 375 325 275 130 3250
125 x 10 x 1 1000 1000 1000 925 850 750 625 525 130 1900
125 x 10 x 2 1000 1000 1000 750 675 600 500 425 130 3350
125 x 10 x 3 1000 1000 750 550 525 450 375 325 130 4650
160 x 10 x 1 1000 1000 1000 1000 925 825 700 575 130 2350
sb_162_a_1_x_cat
160 x 10 x 2 1000 1000 1000 750 700 625 525 425 130 4150
160 x 10 x 3 1000 1000 900 675 625 550 475 375 130 5800
200 x 10 x 1 1000 1000 1000 1000 1000 900 750 625 130 2850
200 x 10 x 2 1000 1000 925 700 625 550 475 400 130 5050
200 x 10 x 3 1000 1000 725 525 500 425 375 300 130 7000
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us.
Dimensions
525 525
40
40 185
130
sb_146_d_1_x_cat
sb_157_d_1_x_cat
R + 80
R + 80
B
R
560 560
Fixed interphase:
q 3 poles: 185 mm
q 4 poles: 130 mm
Our advantages
References
To be
No. ordered
Thickness of of in multiples
Description of accessories the bar (mm) poles Length Quantity of Reference
Slot for 5 mm bars 5 3 6(1) 8 5025 5105
sb_206_a_1_x_cat
Slot for 5 mm bars 5 4 8(1) 8 5025 5105
Slot for 10 mm bars 10 3 6(1) 4 5025 5110
Slot for 10 mm bars 10 4 8(1) 4 5025 5110
Rod kit (bar height 25 to 200
2(1) 4 5025 5100
mm)
(1)
380 mm profile 380 2 4 5025 5124
Order guide
480 mm profile 480 2(1) 4 5025 5125
q With three poles, order: 6 x studs, 2 x rods,
580 mm profile 580 2(1) 4 5025 5126
2 x profiles.
780 mm profile 780 2(1) 4 5025 5128
q With four poles, order: 8 x studs, 2 x rods,
2 m profile 2000 4 5025 5120 2 x profiles.
Profile for Prisma cabinet(2) 525 1(1) 1 5025 5130
(1) Quantity necessary to make 1 busbar support
(2) Kit of 2 profiles and 4 square fixings.
Characteristics
Max. L (distance between centres of supports in mm) for
peak Isc 24 kA 48 kA 63 kA 82 kA 114 kA
Lm
rms Isc 12 kA 23 kA 30 kA 39 kA 52 kA ax.
d min.
sb_021_b_1_x_cat
(1)
Bar x no. (mm) Iz (A)
50 x 5 x 1 975 475 350 275 75 600
50 x 5 x 2 900 450 325 250 175 75 1050
50 x 5 x 3 1000 525 400 300 200 75 1450
63 x 5 x 1 1000 550 425 325 200 75 700
63 x 5 x 2 1000 525 400 300 200 75 1250
63 x 5 x 3 1000 625 475 350 200 75 1800
d
80 x 5 x 1 1000 625 475 375 225 75 900
80 x 5 x 2 1000 625 475 375 225 75 1250
80 x 5 x 3 1000 725 550 425 225 75 2200
Adhering to the maximum distances between two sup-
100 x 5 x 1 1000 725 550 425 225 75 1100
ports ensures the busbar supports are able to withstand
100 x 5 x 2 1000 750 575 425 225 75 1900
the given short circuit current values. At these values,
100 x 5 x 3 1000 875 650 450 225 75 2650
deformation of the copper bars may occur. These defor-
125 x 5 x 1 1000 850 650 500 250 75 1300
mations are permitted by standard IEC 60439-1 as long
125 x 5 x 2 1000 900 675 500 250 75 2350
125 x 5 x 3 1000 1000 800 500 250 75 3250 as they adhere to the insulation distances.
50 x 10 x 1 1000 975 700 400 200 75 850
50 x 10 x 2 1000 950 675 400 200 75 1550
63 x 10 x 1 1000 1000 725 425 200 75 1050
63 x 10 x 2 1000 1000 700 400 200 75 1850
80 x 10 x 1 1000 1000 750 450 225 75 1300
80 x 10 x 2 1000 1000 750 425 225 75 2300
100 x 10 x 1 1000 1000 800 475 225 75 1550
100 x 10 x 2 1000 1000 800 450 225 75 2750
125 x 10 x 1 1000 1000 850 500 250 75 1900
125 x 10 x 2 1000 1000 850 500 250 75 3350
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us.
Dimensions
Mounting A (mm) Enclosure (mm)
q 1 to 3 bars, 5 mm thick, per pole. 380 400
q 1 or 2 bars, 10 mm thick, per pole. 480 500
580 600
q Interphase distance: min 75 mm and max 200 mm.
780 800
q Use 2 rods positioned symmetrically on the outside
of the poles or between the outermost poles. 75 5.8 75 10.8
R+73
R+73
sb_199_a_1_x_cat
sb_198_a_1_x_cat
R
R
d d d d
A A
References
To be
Thickness No. ordered
of the bar of in multiples
Description of accessories (mm) poles Length Quantity of Reference
(1)
Slot for 5 mm bars 5 3 6 8 5025 5205
Slot for 5 mm bars 5 4 8(1) 8 5025 5205
Slot for 10 mm bars 10 3 6(1) 4 5025 5210
Slot for 10 mm bars 10 4 8(1) 4 5025 5210
Rod kit (bar height 25 to 200 mm) 2(1) 4 5025 5100 Order guide
380 mm profile 380 2(1) 4 5025 5124 q With three poles, order: 6 x studs,
480 mm profile 480 2(1) 4 5025 5125 2 x rods, 2 x profiles.
580 mm profile 580 2(1) 4 5025 5126 q With four poles, order: 8 x studs,
2 x rods, 2 x profiles.
780 mm profile 780 2(1) 4 5025 5128
2 m profile 2000 4 5025 5120 (1) Quantity necessary to make 1 busbar support
Profile for Prisma cabinet(2) 525 1(1) 1 5025 5130 (2) Kit of 2 profiles and 4 square fixings.
Characteristics
Dimensions
Mounting A (mm) Enclosure (mm)
q 1 to 3 bars, 5 mm thick, per pole. 380 400
q 1 or 2 bars, 10 mm thick, per pole. 480 500
q Interphase distance: min 75 mm and max 200 mm. 580 600
q Use 2 rods positioned symmetrically on the outside 780 800
of the poles or between the outermost poles.
75 10.8 75 5.8
R+73
R+73
sb_199_a_1_x_cat
sb_198_a_1_x_cat
d d d d
A A
References
To be
Insulation voltage No. of ordered in
Support (VAC) bars Bar width (mm) multiples of Reference
SB 205 1000 13 100 6 5022 5110
SB 306 1000 13 160 6 5023 6110
Characteristics
sb_152_a_1_x_cat
Max. L (distance between centres of supports in mm) for
peak Isc 48 kA 63 kA 82 kA 114 kA 152 kA 165 kA
rms Isc 23 kA 30 kA 39 kA 52 kA 69 kA 75 kA L max.
d min.
Support Bar x no. (mm) Iz (A)(1)
SB 205 100 x 10 x 1 1000 1000 1000 1000 1000 1000 125 1550
SB 205 100 x 10 x 2 1000 1000 1000 1000 1000 1000 125 2750
d min.
SB 205 100 x 10 x 3 1000 1000 1000 1000 1000 1000 125 3850
SB 306 160 x 10 x 1 1000 1000 1000 1000 1000 1000 175 2350
SB 306 160 x 10 x 2 1000 1000 1000 1000 1000 1000 175 4150 Mounting
q SB 205: 1 to 3 bars of max. width 100 mm.
SB 306 160 x 10 x 3 1000 1000 1000 1000 1000 1000 175 5800
q SB 306: 1 to 3 bars of max. width 160 mm.
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us.
Dimensions
99 35 124 35
11 9 9 11
8
38
38
sb_175_a_1_x_cat
8
sb_176_a_1_x_cat
6 4,5 7 5
8 8
= = 20
75 100
QSB 7500 Multipolar flat mounting busbar supports with fixed interphase
References
sb_136_a_3_cat
3 1000 40-50 1 5027 5310
4 1000 40-50 1 5027 5410
Characteristics
sb_153_b_1_x_cat
d
Dimensions
No. of poles A B C J R T1 T2
A C
3 220 38 35 75 52.5 11 6
4 295 38 35 75 52.5 11 6 J
R T1 M8
sb_149_a_1_x_cat
13
7
B
8
T2 75 75
References
No. of poles Insulation voltage (VAC) Bar width (mm) Pack qty Reference
sb_123_a_3_cat
3 1000 50-100 1 5023 0310
4 1000 50-80 1 5023 0410
sb_211_a_1_cat
Mounting bracket
Description of accessories To be ordered in multiples of Reference
2 mounting brackets for SB P 30 1 5024 9002
sb_210_a_1_cat
Description of accessories To be ordered in multiples of Reference
Headless screw for attaching 1 thickness of bar 25 5119 4601
Headless screw for attaching 2 thicknesses of bar 25 5119 4602
Headless screw for attaching 3 thicknesses of bar 25 5119 4603
Characteristics
d = 123 mm
Max. L (distance between centres of supports in mm) for
peak Isc 63 kA 84 kA 110 kA 143 kA 165 kA 176 kA 187 kA 220 kA
rms Isc 30 kA 40 kA 50 kA 65 kA 75 kA 80 kA 85 kA 100 kA
Bar x no. d (mm) Iz (A)
sb_160_a_1_x_cat
50 x 5 x 1 1000 950 525 300 225 200 175 130 123 600
63 x 5 x 1 1000 925 525 300 225 200 175 130 123 700
80 x 5 x 1 1000 900 500 300 225 175 175 125 123 900
80 x 5 x 2 1000 900 500 300 225 175 175 125 123 1550
50 x 10 x 1 1000 950 525 300 225 200 175 130 123 850
50 x 10 x 2 1000 975 525 300 225 200 175 135 123 1550
63 x 10 x 1 1000 925 525 300 225 200 175 130 123 1050
63 x 10 x 2 1000 950 525 300 225 200 175 130 123 1850 L max.
80 x 10 x 1 1000 900 500 300 225 175 175 125 123 1300
sb_200_a_1_x_cat
80 x 10 x 2 1000 925 500 300 225 200 175 125 123 2 300
80 x 10 x 3 1000 950 525 300 225 200 175 130 123 3 200
d
Max. L (distance between centres of supports in mm) for
peak Isc 63 kA 84 kA 110 kA 143 kA 165 kA 176 kA 187 kA 220 kA
rms Isc 30 kA 40 kA 50 kA 65 kA 75 kA 80 kA 85 kA 100 kA
Bar x no. d (mm) Iz (A) Mounting
50 x 5 x 1 1000 1000 800 475 350 300 275 200 185
q 3 poles: 1 to 3 bars of max. width 100 mm per
63 x 5 x 1 1000 1000 800 475 350 300 275 200 185 pole, fixed interphase of 185 mm,
80 x 5 x 1 1000 1000 800 475 350 300 275 200 185 q 4 poles: 1 to 3 bars of max. width 80 mm
80 x 5 x 2 1000 1000 800 475 350 300 275 200 185 per pole, fixed interphase of 123 mm.
100 x 5 x 1 1000 1000 775 450 325 300 250 175 185 1100
100 x 5 x 2 1000 1000 775 450 325 300 250 175 185 1900
100 x 5 x 3 1000 1000 775 450 350 300 250 175 185 2650
50 x 10 x 1 1000 1000 800 475 350 300 275 200 185
50 x 10 x 2 1000 1000 800 475 350 300 275 200 185
63 x 10 x 1 1000 1000 800 475 350 300 275 200 185
63 x 10 x 2 1000 1000 800 475 350 300 275 200 185
80 x 10 x 1 1000 1000 800 475 350 300 275 200 185
80 x 10 x 2 1000 1000 800 475 350 300 275 200 185
80 x 10 x 3 1000 1000 800 475 350 300 275 200 185
100 x 10 x 1 1000 1000 775 450 325 300 250 175 185 1550
100 x 10 x 2 1000 1000 775 450 350 300 250 175 185 2750
100 x 10 x 3 1000 1000 775 450 350 300 275 175 185 3850
Dimensions
185 185 77,5 40
123 123 123 77,5 40
sb_154_c_1_x_cat
55
55
36
36
525 525
560 560
sb_104_a_2_cat
25 M6 5 21 1 5031 2506
30 M6 6 33 1 5031 3006
30 M8 8 33 1 5031 3008
35 M6 8 33 1 5031 3506
35 M8 8 33 1 5031 3508
35 M10 8 33 1 5031 3510
40 M8 10 40 1 5031 4008
40 M10 10 40 1 5031 4010
45 M8 10 41 1 5031 4508
45 M10 10 41 1 5031 4510
50 M8 14 46 1 5031 5008
50 M10 14 46 1 5031 5010
50 M12 14 46 1 5031 5012
60 M10 14 50 1 5031 6010
65 M10 18 55 1 5031 6510
70 M12 25 55 1 5031 7012
Characteristics
Mechanical Max.
Nominal Insulation characteristics tightening
Height voltage (V) voltage (VAC) (daN) torque
H (mm) Insert M AC/DC 50 Hz 1 min Peak Flexion Tention (Nm)
20(1) M4 500 3000 5500 70 170 9
20 M6 500 3000 5500 100 190 8
25 M6 500 3000 5500 170 370 12
30 M6 1000 6000 11000 200 650 22 E M
30 M8 1000 6000 11000 360 800 40
35 M6 1400 9000 16000 230 720 25
sb_105_a_1_x_cat
35 M8 1400 9000 16000 380 900 42
P
H
40 M10 2000 12000 21500 620 1100 60
45 M8 2000 12000 21500 550 1200 55
45 M10 2000 12000 21500 550 1100 65
50 M8 2000 12000 21500 650 1800 60
50 M10 2000 12000 21500 650 1700 70
50 M12 2000 12000 21500 660 13000 130
60 M10 2400 12000 27000 560 1600 85
65 M10 2400 12000 27000 750 1600 90
70 M12 2400 12000 27000 750 1500 135
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us.
sb_106_a_2_cat
25 M6 5 20 10 1 5038 2506
35 M8 8 32 15 1 5038 3508
35 M10 8 32 30 1 5038 3510
50 M8 14 46 25 1 5038 5008
50 M10 14 46 30 1 5038 5010
60 M10 16 50 25 1 5038 6010
sb_107_a_2_cat
25 M5 14 10 1 5039 2505
25 M6 20 10 1 5039 2506
35 M8 32 15 1 5039 3508
35 M10 32 30 1 5039 3510
50 M8 46 25 1 5039 5008
50 M10 46 30 1 5039 5010
60 M10 38 25 1 5039 6010
Headless screw
References
To be ordered in
Length (mm) Thread multiples of Reference
20 M6 20 5032 2006
20 M8 20 5032 2008
sb_121_a_2_cat
25 M6 20 5032 2506
25 M8 20 5032 2508
30 M6 20 5032 3006
30 M8 20 5032 3008
40 M8 20 5032 4008
40 M10 20 5032 4010
50 M12 20 5032 5012
> The indicated short-circuit withstand values will apply if the maximum distances between
two supports with hexagonal insulators are maintained. Values according to IEC 60439-1. L max.
sb_164_a_1_x_cat
d min.
General characteristics
References
Insulation To be ordered in
Support voltage (VAC) No. of bars Bar width (mm) multiples of Reference
SB 1 690 1 20-25 6 5021 0110
SB 2 690 1 32-40 6 5022 0110
Order guide
SB 1: bar of max. width 25 mm
SB 2: bar of max. width 40 mm
Characteristics
Max. L (distance between centres of supports in mm) for
peak Isc 24 kA 48 kA 63 kA 82 kA 114 kA
rms Isc 12 kA 23 kA 30 kA 39 kA 52 kA
sb_014_c_1_x_cat
d min.
Support Bar x no. (mm) Iz (A)(1) L max.
SB 1 20 x 3 x 1 650 325 250 175 135 50 210
SB 1 20 x 5 x 1 850 425 325 250 175 50 280
SB 1 25 x 5 x 1 1000 525 400 300 200 50 330
SB 2 32 x 5 x 1 1000 750 575 450 300 70 410 d min.
SB 2 40 x 5 x 1 1000 950 700 550 400 70 500
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us.
Dimensions
Support A B C J A C
SB 1 50 23 20 34
SB 2 68 23 23.5 50
sb_014_c_1_x_cat
B
6
J
References
Order guide
SB 3: 1 to 2 bars of max. width 63 mm.
Characteristics
sb_008_a_1_x_cat
Bar x no. d min. (mm) Iz (A)(1)
32 x 5 x 2 1000 1000 925 700 500 70 580
40 x 5 x 2 1000 1000 1000 1000 1000 70 700
50 x 5 x 2 1000 1000 1000 925 675 75 850
63 x 5 x 2 1000 1000 1000 1000 1000 85 1000
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us. L maxi
sb_023_b_1_f_cat
d mini
Dimensions
Support A B C J A C
SB 3 bare 65 32 28 36
SB 3 pre-equipped 65 32 28 36
sb_089_b_1_x_cat
B
8
J
References
Characteristics
Max. L (distance between centres of supports in mm) for
peak Isc 10 kA 15 kA 24 kA 38 kA 48 kA 63 kA
rms Isc 6 kA 9 kA 12 kA 19 kA 23 kA 30 kA
Support Bar x no. Iz (A)(1)
Type 1 15 x 3 x 1 950 625 400 250 175 160
Type 1 15 x 5 x 1 1000 825 500 300 175 220
Type 1 15 x 6 x 1 1000 900 550 300 200 250
Type 1 15 x 8 x 1 1000 1000 650 300 200 290
Type 1 20 x 3 x 1 1000 825 525 300 175 210
Type 1 20 x 5 x 1 1000 1000 675 300 175 280
Type 1 20 x 6 x 1 1000 1000 750 300 175 310
Type 1 20 x 8 x 1 1000 1000 775 300 175 370
Type 1 32 x 5 x 1 1000 1000 675 250 170 410
Type 1 32 x 6 x 1 1000 1000 675 250 170 460
Type 2 15 x 3 x 1 950 625 400 250 200 150 160
Type 2 15 x 5 x 1 1000 825 500 325 250 175 220
Type 2 15 x 6 x 1 1000 900 550 350 275 200 250
Type 2 15 x 8 x 1 1000 1000 650 400 325 225 290
Type 2 20 x 3 x 1 1000 825 525 325 250 200 210
Type 2 20 x 5 x 1 1000 1000 675 425 325 225 280
Type 2 20 x 6 x 1 1000 1000 750 450 375 225 310
Type 2 20 x 8 x 1 1000 1000 850 525 375 225 370
Type 2 32 x 5 x 1 1000 1000 1000 525 325 175 410
Type 2 32 x 6 x 1 1000 1000 1000 525 325 175 460
(1) Admissible nominal current for a temperature in the cabinet of 45C and 80C for the bars.
Other assembly configurations: please consult us. Note: Iz is given for solid bars only.
Dimensions
25 25 35.5 35.5 35.5
L L
50
67
35
L L
70
25 25 20.5
35
15.5
sb_041_b_1_x_cat
sb_047_a_1_x_cat
sb_036_e_1_x_cat
49.5
6.2
140
180
90
Type 1: Set of busbars including 3 (or more) equally Type 2: Set of busbars including 3 (or more) SB E 44 Fixation by oblong holes: distance between two holes
spaced SB E 44 supports. supports with doubled intermediary supports. 150 to 170 mm.
References
Pack
No. of poles Insulation voltage (VAC) Bar width (mm) qty Reference
4 690 12-30 1 5026 0460
SB P 10: 1 bar with a thickness of 5 or 10 mm, width 12, 20, 25 or 30 mm.
Characteristics
Max. L (distance between centres of supports in mm) for
peak Isc 10 kA 15 kA 24 kA 48 kA 63 kA
rms Isc 6 kA 9 kA 12 kA 23 kA 30 kA
d min.
Bar x no. (mm) Iz (A)
sb_159_a_1_x_cat
12 x 5 x 1 1000 475 175 60 180
20 x 5 x 1 1000 1000 650 165 60 280
25 x 5 x 1 1000 1000 650 160 60 338
30 x 5 x 1 1000 1000 850 200 120 60 390
25 x 10 x 1 1000 1000 1000 250 150 60 508
30 x 10 x 1 1000 1000 1000 350 200 60 580
Dimensions
242 22
15
sb_144_a_1_x_cat
17
42
62.5 67.5 54
Characteristics
Max. L (distance between centres of supports in mm) for
peak Isc 10 kA 15 kA 24 kA 48 kA 63 kA 82 kA
rms Isc 6 kA 9 kA 12 kA 23 kA 30 kA 39 kA
d min.
Bar x no. (mm) Iz (A)
20 x 5 x 1 1000 1000 800 350 200 125 50 280
sb_165_b_1_x_cat
Dimensions
245 53.5
sb_147_b_1_x_cat
50 50 50
12
114
75.5
150
born_016_a_1_cat
Conformity to standards
born_013_a_1_cat
Function
SOCOMEC power terminals provide connections for power circuits. They consist of
connection plates fixed onto insulating brackets.
Characteristics
General characteristics Composition of the range
q Tin-plated aluminium plates. q 5 terminal models from 250 to 630 A,
q High dielectric strength. with 3 and 4 poles.
q High mechanical resistance. q 2 methods of connection:
q High resistance to damp heat - by lugs,
(supplied "tropicalised"). - by cable clamps.
q Accessories: Inter-phase screen, front cover
to protect against unintentional contact.
Type 1
References Dimensions
Top Bottom 46 50 50 25 22 4
Imax(A) connections by connections by No. of poles A (mm) B (mm) Reference 11
born_001_c_1_x_cat
7
160
Type 2
References Dimensions
Imax Top connections Bottom No. of A 67 65 65 40 18 6
13x15
born_002_b_1_x_cat
(A) by connections by poles (mm) B (mm) Reference
13
7
630 lugs lugs 3P 197 206 4502 0003(1)
250
120
80
630 lugs lugs 4P 262 271 4502 0004(1)
36
15
(1) Terminals supplied without terminal shroud.
34.5 65 65 65 1
30 95
Accessories A
Type Reference
B
1. M6 screws mounting.
Protective cover for 3 pole terminals 4502 1003
Protective cover for 4 pole terminals 4502 1004
Inter-phase screen 4500 0107
Type 3
References Dimensions
born_003_c_1_x_cat
Imax Top connections Bottom No. of A 67 65 65 25 M 10 90
12.5
2.5
2
(A) by connections by poles (mm) B (mm) Reference
1
cable clamps(1) 4503 0003(2)
70
400 lugs 3P 197 206
100
250
400 lugs cable clamps (1)
4P 262 271 4503 0004(2)
(1) 185 mm2 cable clamps included.
(2) Terminals supplied without terminal shroud.
34.5 65 65 65 95
Accessories
A
B
Type Reference
Protective cover for 3 pole terminals 4502 1003
Protective cover for 4 pole terminals 4502 1004
Inter-phase screen 4500 0106
Type 4
References Dimensions
67 65 65 40
4 90
Imax Top connections Bottom No. of A 13x15
born_004_c_1_x_cat
(A) by connections by poles (mm) B (mm) Reference
cable clamps(1) 4504 0003(2)
122
150
500 lugs 3P 197 206
250
Type 5
References Dimensions
67 65 65 40
4 90
Imax No. of A 13x15
born_005_b_1_x_cat
170
250
born_034_a_1_cat
> Electrical distribution.
Enclosures
serre_001_a_1_cat
Cage terminals
Conformity to standards
Cable clamps:
> IEC 60439-1
> DIN 46206
Cage terminals
> IEC 60947-1
(if mounted to
SOCOMEC devices)
Cable clamps
> NF C 63-060
> NF C 63-062
Function Characteristics
SOCOMEC power cable clamps ensure the Cable clamps
connection of copper or aluminium cables q 3 cross-section ranges from 35 to 300 mm2
onto plates or onto bars. q 2 cable clamp models with bracket
Available in aluminium or tin-plated brass, mounting: single-double.
they provide increased mechanical resistance
and high resistance to humidity (supplied
Cage terminals
"tropicalised").
q Ratings: From 160 to 630 A.
SOCOMEC cage terminals are connection
q Number of poles: 3 and 4.
devices fixed onto the connection plates of
SOCOMEC switches, changeover switches q Material: tin-plated aluminium.
and fuse switches. They enable a direct
terminal-free connection to the rigid copper
and aluminium conductors and integration
under the IP2 protective cover.
B
5 - 10
serre_004_c_1_x_cat
Dimensions
B
Tightening capacity (mm2) A B C J J1 = J = C = J1 =
35 185 42 48 35 26 A C
95 240 54 50 45 31.5 35 - 240 mm2 150 - 300 mm2
150 300 53 50 60 33 33
born_018_a_1_cat
16 95 160 4P 14 13 5400 4016
16 185 250 3P 25 18 5400 3025
16 185 250 4P 25 18 5400 4025
50 240 400 3P 45 20 5400 3040
50 240 400 4P 45 20 5400 4040
70 300 630 3P 45 24 5400 3063
70 300 630 4P 45 24 5400 4063
Dimensions X1
Rating of switch
(A) A A1 C E R T X X1 Z X
C
born_019_a_1_x_cat
160 47.5 22.5 25 12 20 3.5 8.5 M12 10 Z
250 62 31.5 31.5 16.5 25 2.5 10.5 M16 14 R
400 71.5 32 38 9 32 5 10.5 M20 15 A1
A
630 76.5 37 38 9 40 5 12.5 M20 15
Dimensions X1 X
R
Rating of switch (A) A A1 C E R T X X1 Z E ini
born_021_a_1_x_cat
Tm
160 47.5 22.5 25 12 20 3.5 8.5 M12 10
C
250 62 31.5 31.5 16.5 25 2.5 10.5 M16 14 Z
A1
400 71.5 32 38 9 32 5 10.5 M20 15 Mini.m)
630 76.5 37 38 9 40 5 12.5 M20 15 (2 m A
repar_020_c_1_cat
repar_008_a_1_cat
repar_028_a_1_cat
repar_042_a
Function
SOCOMEC distribution blocks allow easy connection of conductors.
They are installed downstream of a load break switch, a changeover switch
or a fuse-combination switch.
Characteristics
General characteristics Composition of the range
q Insulation voltage: q 7 ratings from 80 to 360 A in 1, 2, 3
- ferrules terminal distribution block: 500 V, and 4 poles.
- modular row terminal distribution block: q 2 connection modes:
690 V, - direct or ferrules,
- wire-terminal distribution block: 1000 V. - cable lugs.
q Impulse voltage:
- ferrules terminal distribution block: 6 kV,
- modular row terminal distribution block:
6 kV,
- wire-terminal distribution block: 8 kV.
q Self-extinguishing: 960 C.
repar_027_a_2_cat
125 3/4 P 2x25 + 7x10 85 x 88 x 48 3 5420 4108
125 3/4 P 2x25 + 2x16 + 9x10 85 x 129 x 48 4.2 5420 4112
160 3/4 P 1x35 + 3x25 + 8x16(2) 90 x 160.5 x 50 6.2 5420 4016
(1) Short circuit withstand (rms value) 1 second.
(2) Maximum section of flexible cable.
Dimensions
repar_009_a_1_x_cat
Rating (A) H (mm) W (mm) D (mm)
H
P
125 98 74.5 45
175 80 71.5 42.5
L
Direct or cable connection distribution blocks which can
be clipped onto a symmetric DIN rail.
repar_039_a_1_cat
Rating (A) No. of poles Dimensions H x W x D (mm) Reference
125 4P 98 x 74.5 x 45 5410 4112
175 3P 80 x 71.5 x 42.5 5410 3017
repar_008_a_2_cat
125 65 4.4 5410 1012
175 60.5 11 5410 1017
250 86 21 5410 1025
400 86 21 5410 1040
Description of accessories Reference
Connection for rating 250 A(1) 5410 0025
Connection for rating 400 A(1) 5410 0040
(1) Linking part enabling direct assembly on the connecting lugs of the switching device.
Dimensions 30 (1)
Rating (A) Dimensions H x W x D (mm) Icc (kA rms)(1) 10.8
40
80 66 x 27 x 47 1.9 32
4
250 96 x 45 x 50 21
400 96 x 45 x 50 21
86.5
Connections
Rating (A) Power supply section (mm2) No of phases per section (mm2)
80 < 16 4 x 6 + 2 x 16
6.3 29.5
125 < 35 6 x 2.5 to 16 L P
175 16 70 10 x 2.5 to 16
250 35 120 2 x 25 + 5 x 16 + 4 x 10 Direct or cable connection distribution blocks, IP20
400 95 185 2 x 25 + 5 x 16 + 4 x 10 which can be clipped onto a symmetric DIN rail.
Phase: 5 x 1 to 6 + 2 x 1.5 to 10 /
125
Neutral: 6 x 1.5 to 10 + 4 x 1.5 to 6
175 6 x 2.5 to 16
Earth bar
References
barre_006_a_2_cat
References
repar_028_a_2_cat
With connector
Rating (A) Length leads(1) Icc (kA rms) Reference
250(2) 1 row yes 10 5420 2426
250(2) 1 row no 10 5421 2426
(1) Delivered with 6 mm2 connector leads, L = 120 mm, 12 black connectors, 12 blue connectors.
(2) Preferably the terminations will be distributed over the entire number or terminals.
Dimensions
25 60 60
Cables
repar_029_a_1_x_cat
Rating Length To be ordered in
72.4
(A) Type (mm) Colour multiples of Reference
40
40 6 mm2 cable 120 Blue 4 5421 1006
40 6 mm2 cable 120 Black 10 5421 1016 407.5 46
40 6 mm2 cable 320 Blue 10 5421 1106 423
40 6 mm2 cable 320 Black 10 5421 1116
63 10 mm2 cable 320 Blue 10 5421 1101
63 10 mm2 cable 320 Black 10 5421 1111
2.5 mm2
40 20 5421 0025
connector
2
63 6 mm connector 20 5421 0125
References
repar_042_a
Dimensions No of
Rating (A) H x W x D (mm) Phase Neutral Reference
80 50 x 24 modules x 40 3x8 2x8 5420 2408
80 50 x 36 modules x 40 3 x 12 2 x 12 5420 3608
Terminal connections
Multipolar distribution blocks
References
No of feeders per section
Rating (A) No. of poles Icc (kA rms) (mm2) Reference
160 3P 10 2 x 95 + 8 x 25 5412 3016
160 4P 10 2 x 95 + 8 x 25 5412 4016
250 3P 15 2 x 150 + 8 x 50 5412 3025
250 4P 15 2 x 150 + 8 x 50 5412 4025
400 3P 21 2 x 240 + 8 x 95 5412 3040
repar_007_b_1_cat
400 4P 21 2 x 240 + 8 x 95 5412 4040
630 3P 21 2 x 300 + 8 x 150 5412 3063
630 4P 21 2 x 300 + 8 x 150 5412 4063
Dimensions
Rating No. of P P P
==
(A) poles A B E H J K L P R T X X1 Y
X
160 3P 154 286 73 46.5 122 207 6.5 36 20 4 9 6 54
160 4P 190 286 73 46.5 158 207 6.5 36 20 4 9 6 54
H
250 3P 210 307 83 57.5 50 222 7 50 25 4 11 8 56
250 4P 260 307 83 57.5 100 222 7 50 25 4 11 8 56
400 3P 281 375 116 82.5 65 270 8 65 32 5 14.5 8.5 82 8 x X1
400 4P 346 375 116 82.5 130 270 8 65 32 5 14.5 8.5 82
K
630 3P 271 438 117 90.5 65 333 8 65 40 6 14.5 10.5 83
630 4P 346 438 117 90.5 130 333 8 65 40 6 14.5 10.5 83
L
H
repar_004_b_1_x_cat
T
R Y
J E
=A =
= =
Terminal connections distribution blocks with front
protection cover against direct contact.
References
Rating (A) No. of poles Reference
60
125/160 3P 3699 3P16 1
125/160 4P 3699 3P16
50 9 17.5
8
250/400 3P 3699 3P39
MIN 24
MAX 33
sb_186_a_1_x_cat
3 D
F
repar_012_b_1_cat
(A) (mm) poles (kA rms) supports Reference Reference
160 270 4P 25 2 5028 0421 5028 0411
160 420 4P 17 2 5028 0451 5028 0412
160 620 4P 20 3 5028 0471 5028 0413
250 270 4P 30 2 5028 0423 5028 0411
250 420 4P 22 2 5028 0453 5028 0412
250 620 4P 18 3 5028 0473 5028 0413
400 270 4P 24 2 5028 0425 5028 0411
400 420 4P 21 2 5028 0455 5028 0412
400 620 4P 13 3 5028 0475 5028 0413
Dimensions L 140
Type Pack qty Reference A P
Spacer for protection cover 1 5028 0415
M6
R
Rating (A) Nb of terminations A D E L P R
repar_040_a_1_x_cat
180
127
160 9 250 8 150 270 5 15 D
160 15 400 8 300 420 5 15
160 21 600 8 250 620 5 15
250 9 250 10 150 270 5 20
25 E
250 15 400 10 300 420 5 20
250 21 600 10 250 620 5 20 Stair type distribution blocks with threaded holes. Can be
400 8 225 12 150 270 5 32 clipped onto a symmetric DIN rail.
400 14 375 12 300 420 5 32 Factory assembled and supplied without protection cover
400 20 620 12 250 620 5 32
References
repar_030_a_2_cat
Rating (A) Connection type Reference
160 Terminal connections NB16 0000
250 Terminal connections NB16 0000
400 Terminal connections NB40 0000
630 Terminal connections NB63 0000
A
Dimensions
shunt_012_a_1_x_cat
Width max.
Rating (A) A B C D E (mm)
E
repar_020_b_1_cat
250 3P 15 1 x 150 + 8 x 50 5411 3025
250 4P 15 1 x 150 + 8 x 50 5411 4025
400 3P 21 1 x 240 + 8 x 95 5411 3040
400 4P 21 1 x 240 + 8 x 95 5411 4040
630 3P 21 1 x 300 + 8 x 150 5411 3063
630 4P 21 1 x 300 + 8 x 150 5411 4063
Dimensions
Rating (A) No. of poles A B E H K P R T Y
160 3P 154 286 73 46.5 261.5 36 20 4 54
160 4P 190 286 73 46.5 261.4 36 20 4 54
250 3P 210 307 83 57.5 279 50 25 4 56
250 4P 260 307 83 57.5 279 50 25 4 56
400 3P 281 375 116 82.5 340 65 32 5 82
K
400 4P 346 375 116 82.5 340 65 32 5 82
repar_003_c_1_x_cat
630 3P 271 438 117 90.5 410.5 65 40 6 83
630 4P 346 438 117 90.5 410.5 65 40 6 83
H R T
P P P Y
A E
Dimensions
No. of
Rating (A) poles Device A B E H K P R T Y
100/125/160 3P FUSERBLOC 110 260 61 20 233 36 20 4 39
100/125/160 4P FUSERBLOC 145 260 61 20 233 36 20 4 39
B
Conformity to standards
> EN 60715
elcha_039_a_1_cat
Function
SOCOMEC frame parts come in steel, 304 L stainless steel or aluminium
(profiles and accessories) and allow the fixing of any electrical equipment.
Configurations
11
10
QProfile C
References
Perforation
WxHxe Perforations centres Profiles To be ordered
(mm) (mm) (mm) Material length (m) in multiples of Reference
20 x 14 x 1.5 8.2 x 40 50 Steel z-b(1) 3 30 m 5000 0120
30 x 15 x 1.5 8.2 x 40 50 Steel z-b(1) 3 30 m 5000 0121
35 x 35 x 2 8.2 x 40 50 Steel z-b(1) 2 12 m 5000 0132
elcha_042_a_1_cat
35 x 35 x 2 8.2 x 40 50 Steel z-b(1) 3 18 m 5000 0122
30 x 15 x 1.5 6.3 x 18 50 Stainless steel 2 10 m 5000 1021
20 x 15 x 2 without Aluminium 2 10 m SA12 4202
20 x 15 x 2 without Aluminium 3 15 m SA13 4202
20 x 15 x 2 without Aluminium 6 30 m SA10 4202
29 x 19 x 2.5 without Aluminium 2 10 m SA12 4201
29 x 19 x 2.5 without Aluminium 3 15 m SA13 4201
29 x 19 x 2.5 without Aluminium 6 30 m SA10 4201
(1) White zinc-coated.
Accessories
Screws
Dimensions H x To be ordered
Type Insert M W (mm) For profiles in multiples of Reference
elcha_016_a_1_x_cat
Rhomboidal nut M3 15.5 x 15.5 20 x 14 100 5000 0023
Rhomboidal nut M4 15.5 x 15.5 20 x 14 100 5000 0024
Rhomboidal nut M5 15.5 x 15.5 20 x 14 100 5000 0025
Rhomboidal nut M6 15.5 x 15.5 20 x 14 100 5000 0026
Rhomboidal nut
Rhomboidal nut M8 15.5 x 15.5 20 x 14 100 5000 0028
Rhomboidal nut M8 25 x 25 30 x 15 100 5000 0029
Square nut M8 35 x 28 35 x 35 100 5000 0037
elcha_017_a_1_x_cat
Square nut M18 35 x 28 35 x 35 100 5000 0039
Rhomboidal nut M3 33 x 11 30 x 15 100 5000 0033
Rhomboidal nut M4 33 x 11 30 x 15 100 5000 0034
Rhomboidal nut M5 33 x 11 30 x 15 100 5000 0035 Square nut
Rhomboidal nut M6 34 x 20 35 x 35 100 5000 0036
Rhomboidal nut M8 34 x 20 35 x 35 100 5000 0038
elcha_018_a_1_x_cat
Straddle bracket 8.2 20 x 14 100 5000 0010
Straddle bracket 8.2 30 x 15 100 5000 0011
Straddle bracket 8.2 35 x 35 100 5000 0012
Rhomboidal nut
elcha_020_a_1_x_cat
Straddle bracket
Foam
elcha_040_a_1_cat
35 x 7.5 x 1 Without Steel z-b(1) 2 30 m 5000 0302
35 x 7.5 x 1 6.3 x 18 25 Steel z-b(1) 2 30 m 5000 0042
35 x 7.5 x 1 Without Stainless steel 2 10 m 5000 1302
(1) White zinc-coated.
elcha_043_a_1_cat
35 x 15 x 1.5 Without Steel z-b(1) 3 30 m 5000 0331
35 x 15 x 2.3 Without Steel z-b(1) 2 20 m 5000 0017
35 x 15 x 2.3 Without Steel z-b(1) 3 30 m 5000 0027
35 x 15 x 1.5 6.3 x 18 25 Steel z-b(1) 2 30 m 5000 0043
35 x 15 x 1.5 6.3 x 18 25 Steel z-b(1) 3 30 m 5000 0343
35 x 15 x 2.5 Without Aluminium 2 12 m SA12 4217
35 x 15 x 2.5 Without Aluminium 3 18 m SA13 4217
35 x 15 x 2.5 Without Aluminium 6 36 m SA10 4217
(1) White zinc-coated.
elcha_041_a_1_cat
32 x 15 x 1.5 Without Steel z-b(1) 2 30 m 5000 0307
32 x 15 x 1.5 Without Steel z-b(1) 3 30 m 5000 0308
32 x 15 x 1.5 6.3 x 18 25 Steel z-b(1) 2 30 m 5000 0044
32 x 15.5 x 1.5 Without Aluminium 2 8m SA12 4210
32 x 15.5 x 1.5 Without Aluminium 3 12 m SA13 4210
32 x 15.5 x 1.5 Without Aluminium 6 24 m SA10 4210
(1) White zinc-coated.
Accessories
Fixomega / Fixocap
Type Insert M To be ordered in multiples of Reference
Fixomega(1) M4 100 5000 0041
elcha_019_b_1_x_cat
Perforation
Perforations centres Profiles To be ordered
W x H x e (mm) (mm) (mm) Material length (m) in multiples of Reference
30 x 15 x 1 8.2 x 14.5 16.7 Galvanised steel 3 15 m 5000 4325
50 x 12 x 1 8.2 x 14.5 16.7 Galvanised steel 2 20 m 5000 4326
QL profile
WxHxe perforations Perforation Profiles To be ordered
elcha_034_a_1_cat
(mm) (mm) centres (mm) Material length (m) in multiples of Reference
30 x 30 x 2.5 8.2 25 Steel z-b(1) 2 10 m 5254 6401
30 x 50 x 2.5 8.2 25 Steel z-b(1) 2 10 m 5254 6501
30 x 30 x 2.5 8.5 x 45 55 Steel z-b(1) 2 10 m 5000 0003
40 x 40 x 2.5 8.5 x 45 55 Steel z-b(1) 2 10 m 5000 0004
(1) White zinc-coated.
QU profile
perforations Perforation Profiles To be ordered
elcha_035_a_1_cat
W x H x e (mm) (mm) centres (mm) Material length (m) in multiples of Reference
50 x 30 x 2.5 8.2 25 Steel z-b(1) 2 10 m 5254 6701
30 x 20 x 3 9 25 Aluminium 3 3m 5254 6901
(1) White zinc-coated.
QZ profile
To be
elcha_036_a_1_cat
perforations Perforation Profiles ordered in
W x H x e (mm) (mm) centres (mm) Material length (m) multiples of Reference
30 x 30 x 2.5 8.2 25 Steel z-b(1) 2 10 m 5254 6601
(1) White zinc-coated.
QRising U
To be
elcha_037_a_1_cat
perforations Perforation Profiles ordered in
W x H x e (mm) (mm) centres (mm) Material length (m) multiples of Reference
30 x 50 x 2.5 8.2 x 45 55 Steel z-b(1) 2 8m 5000 0005
(1) White zinc-coated.
Accessories
Bracket
Use Characteristics
For steel profile. Bichromate zinc-coated steel.
Number of
elcha_021_a_1_x_cat
H x W x D (mm) hole (mm) Insert M To be ordered in multiples of Reference
holes
25 x 25 x 19 2 7 25 5000 0045
25 x 25 x 19 1 6 M6 25 5000 0046
36 x 36 x 23 2 8 25 5000 0047
45 x 60 x 25 2 9x25 / 9x35 25 5254 6101
44 x 75 x 32 5 5/6 1 (Set of 6) 5119 5045
Screws
Use Characteristics
For steel profile. Bichromate zinc-coated steel.
elcha_038_a_1_x_cat
Integrated washer
Thread L (m) Class To be ordered in multiples of Reference
M6 10 8.8 100 5000 0066
M8 12 8.8 100 5000 0068
M8 16 8.8 100 5000 0069
Washer
Use Characteristics
For steel profile. Bichromate zinc-coated steel.
amc_035_a_1_x_cat
PVC border
amc_036_a_1_x_cat
Use Characteristics
PVC border for sheet metal. Colour: Ligth grey
Steel thickness (mm) To be ordered in multiples of Reference
2 25 m 7739 0025
Explosive atmospheres
SIDER SIDER
Steel-Dust Steel-Gas Photovoltaic
SN SN products
(3 / 4 / 6P) (3 / 4P)
p. 618 p. 618 We will help you
jMCSGDQHFGS
solution for your
application.
Enclosed changeover switches
Manual control
Polyester
enclosure Steel enclosure
SN SN
(3 / 4P) (3 / 4P)
p. 624 p. 624
A specialist in breaking, switching, The culmination of many years of Did you know?
& solutions
IEC 61439
Enclosed switches
Switching enclosures incorporate disconnection, breaking and interlocking of
load break switches with or without the power supply for all types of load, and
fuse protection, which are developed, can also be used as general switches for
qualified and certified for electrical equipment in a variety of applications.
distribution networks in the industrial and
RDQUHBDRDBSNQR
3GDXDM@AKDNMKN@C
2(3$
Safety enclosures
Safety enclosures are designed for For use in explosive atmospheres (gas/
installation near a motor or a machine CTRS@M 3$7UDQRHNMHR@U@HK@AKDSN
in order to isolate it from the power prevent explosions during the device's
supply voltage
3GDXBNLOQHRDL@MT@KKX opening and closing phases, which can
controlled load break switches which generate electrical arcs.
can be interlocked in the OFF position
with visible and reliable indication of the
disconnection open position.
During maintenance or inspection
operations, they guarantee the operator's
protection against the accidental startup
of electrical machines.
2(3$
Photovoltaic enclosures
Photovoltaic enclosures are designed to U@HK@AKDHMSGQDDUDQRHNMRQDRHCDMSH@K
combine photovoltaic module strings and buildings and solar fields), the SOCOMEC
to provide protection against overcurrents range of photovoltaic enclosures meets a full
or overvoltages, in order to connect them range of requirements with a manufacturer's
SNRNK@QHMUDQSDQR
3GDHQ"K@RR((BNMRSQTBSHNM guarantee.
enables them to offer maximum protection for
users against indirect contacts.
2(3$
> OEM.
& solutions
> Industries.
> Service sector buildings.
> Power distribution.
coff_295_a_1_cat
coff_292_a_1_cat
Strong points
SIRCO
in polyester enclosure > Safety of operations.
SIRCO M > Inductive load breaking (AC23).
in polycarbonate enclosure
> Complete range.
Conformity to standards
Dimensions
SIRCO M 16 to 40 A
20
68
sircm_130_c_1_cat
111
162
150
0.4
99
SIRCO M 63 to 100 A
113
15
68
sircm_131_b_1_cat
111
186
0.4
125.5
Dimensions
M
Ah
Z
coff_114_d_1_gb_cat
N
H
Z1
B1
Ab
W D 45
Top/Bottom Bottom/Bottom
connection connection
Connection M N Z Z1 Ah B1 Weight Ab B1 Weight
Rating (A) H x W x D (mm) cross-section (mm2) (mm) (mm) (mm) (mm) (mm) (mm) (kg) (mm) (mm) (kg)
125 360 x 270 x 171 50 271 361 33 120 126 5
125 360 x 270 x 201 50 271 361 62 28 166 205 6
160 360 x 270 x 171 95 271 361 33 120 126 5
160 360 x 270 x 201 95 271 361 62 28 166 205 6
250 540 x 360 x 171 150 361 541 35 200 210 8
250 540 x 360 x 201 150 361 541 55 25 279 360 10
400 720 x 540 x 201 240 541 721 42 258 258 18 316 433 23
500 720 x 540 x 201 240 541 721 51 38 258 258 18 316 433 24
> OEM.
& solutions
> Industries.
> Data centres.
> Power distribution.
> Solar applications.
coff_284_a_2_cat
coff_320_a_1_cat
FUSERBLOC
in steel enclosure
coff_319_a_1_cat
Conformity to standards
Advantages
Available on request
Safety of operation Suitable for use in a variety of applications
Enclosed FUSERBLOC provide: FUSERBLOC can be fitted with different types > Customised solutions upon
q Positive break indication and door of fuses (gG, aM, UR) with high breaking request.
interlocking. capacity, enabling them to be utilised in a
> For BS88 versions please
q Short-circuit and overcurrent protection. variety of applications.
consult us.
q Complete isolation of the fuse with double
breaking per pole (top and bottom of fuse).
q Protection to personnel against contact with
live parts.
q Protection against environmental factors.
General characteristics
q Adapted to environments subject to q Material: glass fibre reinforced polyester.
chemical, dust, contamination and q Coating: N/A.
coff_319_a_2_x_cat
References
Top/Bottom Bottom/Bottom
connection connection
(1)
Rating (A) Fuses NFC and DIN Reference Reference
3 x 50 14 x 51 3117 3005 3117 3005
4 x 50 14 x 51 3117 4005 3117 4005
3 x 100 22 x 58 3117 3010 3127 3010
4 x 100 22 x 58 3117 4010 3127 4010
3 x 160 0 3117 3016 3127 3016
4 x 160 0 3117 4016 3127 4016
3 x 250 1 3117 3025 3127 3025
4 x 250 1 3117 4025 3127 4025
3 x 400 2 3117 3040 3127 3040
4 x 400 2 3117 4040 3127 4040
(1) Fuses supplied separately; please see the fuse section of this catalogue or consult us.
Dimensions
M
Ah
Z
coff_114_d_1_gb_cat
N
H
Z1
B1
Ab
W D 45
Top/Bottom Bottom/Bottom
Connection connection connection
HxWxD cross-section M N Z Z1 Ah B1 Weight Ab B1 Weight
Rating (A) (mm) (mm2) (mm) (mm) (mm) (mm) (mm) (mm) (kg) (mm) (mm) (kg)
(1)
3 x 50 / 4 x 50 270 x 270 x 171 25 271 271 24 86 86 90 90 3
3 x 100 / 4 x 100 360 x 270 x 171 95 271 361 20 108 107 4
(1) (1) (1) (1) (1) (1) (1) (1) (1) (1)
3 x 100 / 4 x 100 540 x 270 x 201 95
3 x 160 540 x 270 x 171 95 271 541 20 220 180 6
3 x 160 540 x 270 x 201 95 271 541 60 25 220 320 8
4 x 160 540 x 360 x 171 95 361 541 20 220 180 7
4 x 160 540 x 360 x 201 95 361 541 60 25 220 320 10
3 x 250 / 4 x 250(1)
3 x 400 / 4 x 400(1)
(1) Please consult us.
General characteristics
q Adapted to environments subject to q Closing plate: N/A.
chemical, dust, contamination and q Material: glass fibre reinforced polyester.
atmospheric corrosion risks. q
coff_320_a_1_cat
Coating: N/A.
q Operation handle: S-type black padlockable q Wall mounting: 4 fixing lugs supplied, not
handle. mounted.
q Protection degree: IP55 / IK 10. q Locking system: screw.
q Colour: RAL 7030.
References
Top/Bottom Bottom/Bottom
connection connection
(1)
Rating (A) Fuses NFC and DIN Reference Reference
3 x 50 14 x 51 3167 3005 3167 3005
4 x 50 14 x 51 3167 4005 3167 4005
3 x 100 22 x 58 3167 3010 3167 3010
4 x 100 22 x 58 3167 4010 3167 4010
3 x 160 0 3167 3016 3177 3016
4 x 160 0 3167 4016 3177 4016
3 x 250 1 3167 3025 3177 3025
4 x 250 1 3167 4025 3177 4025
3 x 400 2 3167 3040 3177 3040
4 x 400 2 3167 4040 3177 4040
(1) Fuses supplied separately; please see the fuse section of this catalogue or consult us.
Dimensions
M
Ah
Z
N
H
coff_119_f_1_gb_cat
Z1
B1
Ab
W 45 D
Top/Bottom Bottom/Bottom
Connection connection connection
HxWxD cross-section M N Z Z1 Ah B1 Weight Ab B1 Weight
Rating (A) (mm) (mm2) (mm) (mm) (mm) (mm) (mm) (mm) (kg) (mm) (mm) (kg)
3 x 50 / 4 x 50 270 x 270 x171 25 271 271 24 84 88 4 84 88 4
3 x 100 / 4 x 100 360 x 270 x 171 95 271 361 20 108 108 5 108 108 5
3 x 160 540 x 270 x 171 95 271 541 260 140 6
4 x 160 540 x 360 x 171 95 361 541 20 260 140 7
3 x 160 / 4 x 160 540 x 360 x 201 95 361 541 52 24 200 289 8
3 x 250 720 x 360 x 201 240 361 721 20 328 228 15
(1)
4 x 250 720 x 360 x 201 240 361 721 20 338 218
3 x 250 / 4 x 250 720 x 360 x 201 240 361 721 51 29 255 453 18
3 x 400 / 4 x 400 720 x 540 x 201 240 541 721 25 323 223 18
3 x 400 720 x 540 x 201 240 541 721 25 40 450 403 23
(1)
4 x 400 754 x 750 x 312 240 801 618 25 40 436 484
(1) Please consult us.
References
Top/Bottom
connection
Rating (A) Fuses NFC and DIN(1) Reference
3 x CD 25 10 x 38 3033 3002
4 x CD 25 10 x 38 3033 4002
3+N x CD 25 10 x 38 3033 5002
3 x CD 32 W 3033 3003
4 x CD 32 14 x 51 3033 4003
3+N x CD 32 14 x 51 3033 5003
3 x 63 00C 3033 3006
4 x 63 00C 3033 4006
3+N x 63 00C 3033 5006
3 x 100 22 x 58 3033 3010
4 x 100 22 x 58 3033 4010
3+N x 100 22 x 58 3033 5010
3 x 160 00 3033 3016
4 x 160 00 3033 4016
3+N x 160 00 3033 5016
3 x 250 1 3033 3025
4 x 250 1 3033 4025
3+N x 250 1 3033 5025
3 x 400 2 3033 3040
4 x 400 2 3033 4040
3+N x 400 2 3033 5040
3 x 630 3 3033 3063
4 x 630 3 3033 4063
3+N x 630 3 3033 5063
3 x 800 3 3033 3080
4 x 800 3 3033 4080
3+N x 800 3 3033 5080
(1) Fuses supplied separately; please see the fuse section of this catalogue or consult us.
Accessories Dimensions
q For auxiliary contacts: Top/Bottom
(See page 203). connection
q Terminal shrouds (see page 203). Max. connection
Rating HxWxD cross-section E M N Z Ah B1 Weight
(A) (mm)(1) (mm2) (mm) (mm) (mm) (mm) (mm) (mm) (kg)
(1)
M CD 25 300 x 300 x 150 16 208 348 259 28.5 115 87
W E CD 32 300 x 300 x 150 16 208 348 259 28.5 115 87 (1)
(1)
63 300 x 300 x 150 25 208 348 259 23.8 101.5 101.5
(1)
Z 100 400 x 300 x 200 95 259 348 359 20 109.5 149.5
Ah
coff_248_f_1_gb_cat
(1)
160 400 x 300 x 200 95 259 348 359 20 109.5 149.5
(1)
250 600 x 600 x 300 240 359 648 559 22 187 247
H
N
(1)
400 600 x 600 x 300 240 359 648 559 22 184 244
(1)
630 800 x 600 x 300 2 x 300 374 648 759 59 264 276
B1
(1)
800 800 x 600 x 300 2 x 300 374 648 759 59 264 276
(1) Weight (kg): Please consult us.
D
Socomec safety enclosures are designed operations, the safety enclosures guarantee
& solutions
SITE_258_A
During maintenance or inspection
Atmosphere
Normal Explosive
Gas Dust
Environment Steel enclosure Polyester enclosure Stainless steel enclosures(1) ATEX enclosures
Chemical aggression
Mechanical risks
Dust risks
Contamination risks
Atmospheric corrosion
Risk of explosion
Safety functions
Positive break indication Visible breaking
In position 1 In position 0
COFF_036_A_2_CAT
COFF_035_A_2_CAT
COFF_234_A_1_CAT
COFF_233_A_1_CAT
Clear indication of the open or closed position of the switch via the In accordance with NF C 15 100, "an isolating device is considered
handle and its easy-to-read marking. as having visible breaking if the separation of the contacts is directly
visible." All the devices used in the safety enclosures have visible
breaking.
COFF_042_A_2_CAT
COFF_043_A_2_CAT
COFF_221_A_2_CAT
When working on the machine during the lockout phase, qualified Flush with the viewing glass and integral with the movable bar, this
personnel may perform triple handle padlocking in the open position. gives clear, at-a-glance indication of contact position, providing easier
The ergonomic handle can accommodate up to three locks. visualisation of the visible breaking.
Double locking
COFF_034_A_1_CAT
COFF_037_A_2_CAT
COFF_038_A_2_CAT
In accordance with standard 60204-1, devices located outside a It is possible to close the breaking device when the enclosure door is
closed electrical service area must be equipped with the means to open by using a tool to inhibit the double lock, thus allowing tests to be
allow them to be secured in the OFF position (disconnected state). carried out by qualified staff.
Qualified personnel may use the ergonomic handle to perform triple
handle padlocking.
COFF_047_A
COFF_163_A
COFF_156_A
coff_163_a_3_cat
Polyester enclosure
with front operation handle
Strong points
Polyester enclosure > Safety of operations.
with side operation handle
> Inductive load breaking (AC23).
> Robust product.
Function
Safety enclosures equipped with SOCOMEC switches provide emergency breaking, breaking Conformity to standards
for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit.
> IEC 60364
> IEC 60947-3
> IEC 60204-1
Advantages > IEC 61439-2
General characteristics
References
Front operation Front operation(1)(2) Side operation(1)(2)
Bottom/ Bottom/
Top/Bottom
Top/Bottom Bottom Bottom
connection
connection connection connection
Rating No. of
Reference Reference
Rating No. of (A) poles
Reference Reference
(A) poles 50 3P 3265 3005 3265 3005
125 3P 3215 3012 3225 3012 50 4P 3265 4005 3265 4005
125 4P 3215 4012 3225 4012 50 6P 3265 6005 3265 6005
125 6P 3215 6012 3225 6012 80 3P 3265 3008 3265 3008
200 3P 3215 3020 3225 3020
coff_219_a_2_cat
(1) For the mechanical indicator option, replace the second digit of the enclosure reference number with the letter V.
For example: 3V15 3012.
(2) Stainless steel enclosures, specific locking systems, terminal pre-wired/non pre-wired control auxiliary contacts, ventilation
and humidity evacuation systems or cable glands are available upon request. Please consult us.
Accessories
Auxiliary contacts
Use Mounting
For pre-breaking and signalling of q On the double locking system.
positions 0 and I of the load break q Possibility of factory mounting
1st NO/NC A/C for pre-break
coff_177_a_1_cat
2 1 4
Factory fitted
Factory fitted
Contact(s) A/C low level
A/C
auxiliary:
1st NO/NC changeover A/C
2799 0001 2799 1001(1)
EQNMSNODQ@SHNM
2nd NO / NC A/C for pre-break
2nd NO/NC changeover A/C (1)
2799 0002 2799 1002
EQNMSNODQ@SHNM
coff_003_a_1_x_cat
coff_205_c_1_cat
Locking using XOP10 lock (not included) 3290 7015 3290 7016(1)
Lock RONISEL11AP 4409 8511
Serv Trayvou XOP10 lock 4409 8601
(1) Please provide the reference number of the enclosure to be equipped.
Dimensions
Front operation
Top/Bottom Bottom/Bottom
connection connection
Connection
Rating No. of cross-section Ah B1 Weight Ab B1 Weight
(A) poles H x W x D (mm) (mm2) (mm) (mm) (kg) (mm) (mm) (kg)
Ah
Ab
Side operation
Top/Bottom Bottom/Bottom
connection connection
Connection
Rating No. of cross-section Ah B1 Weight Ab B1 Weight
(A) poles H x W x D (mm) (mm2) (mm) (mm) (kg) (mm) (mm) (kg)
50 3/4 P 270 x 180 x 171 16 84 116 3 116 3
50 6P 270 x 360 x 201 16 84 116 5 116 5
Ah
Steel enclosure
with side operation handle
coff_156_b_1_cat
Strong points
Function
Conformity to standards
Safety enclosures equipped with SOCOMEC switches provide emergency breaking, breaking
for mechanical maintenance and safety isolation in the vicinity of any low voltage final circuit. > IEC 60364
> IEC 60947-3
> IEC 60204-1
> IEC 61439-2
Advantages
Specific requests
Safety of operations Robust product
q Visible contacts and positive break indication Product has been designed for industrial > SOCOMEC can offer you
with the possibility to add a mechanical environments with either mechanical risks or
customised solutions to meet
indicator. non-explosive dust risks (galvanised steel,
thickness 2 mm, triplex glass, metal handle, etc.) your specific requirements.
q Double locked door when switch is in the
ON position. Contact your Socomec office
q Triple locking of the handle in the OFF for further information.
position.
General characteristics
References
Front operation Front operation(1)(2) Side operation(1)(2)
Bottom/ Bottom/
Top/Bottom Bottom Top/Bottom Bottom
connection connection connection connection
Rating No. of Rating No. of
(A) poles Reference Reference (A) poles Reference Reference
50 3P 3211 3005 3221 3005 50 3P 3261 3005 3271 3005
50 4P 3211 4005 3221 4005 50 4P 3261 4005 3271 4005
80 3P 3211 3008 3221 3008 50 6P 3261 6005 3271 6005
coff_156_b_1_cat
1600 3P 3211 3160 3221 3160 1250 4P 3261 4120 3271 4120
1600 4P 3211 4160 3221 4160 1600 3P 3261 3160 3271 3160
1600 4P 3261 4160 3271 4160
(1) For the mechanical indicator option, replace the second digit of the enclosure reference number with the letter V.
For example: 3V11 3005.
(2) Stainless steel enclosures, specific locking systems, terminal pre-wired/non pre-wired control auxiliary contacts, ventilation and
humidity evacuation systems or cable glands are available upon request. Please consult us.
Accessories
Auxiliary contacts
Use Mounting
For pre-breaking and signalling of q On the double locking system.
positions 0 and I of the load break q Possibility of factory mounting
coff_177_a_1_cat
Factory fitted Factory fitted low 1st NO/NC AC for pre-break 2nd NO / NC AC for pre-break
Contact(s) A/C A/C level auxiliary:
2 4 12 14
coff_003_a_1_x_cat
Red handle
Use
Red steel handle for load break or emergency stop operation.
coff_181_a_1_cat
Dimensions
Front operation
Top/Bottom Bottom/Bottom
connection connection
Connection
Rating No. of cross-section Ah B1 Weight Ab B1 Weight
(A) poles H x W x D (mm) (mm2) (mm) (mm) (kg) (mm) (mm) (kg)
H
Ab
Side operation
Top/Bottom Bottom/Bottom
connection connection
Connection
Rating No. of cross-section Ah B1 Weight Ab B1 Weight
(A) poles H x W x D (mm) (mm2) (mm) (mm) (kg) (mm) (mm) (kg)
50 3/4 P 300 x 200 x 150 16 120 130 9 160 9
H
Ab
1250 4P 1200 x 700 x 400 4 x 185 465 465 74 670 770 100
1600 3P 1200 x 600 x 400 4 x 300 445 445 75 650 790 100
P 1600 4P 1200 x 700 x 400 4 x 300 445 445 76 650 790 110
> &HPHQWZRUNV
> Mining industries.
coff_280_b_1_cat
Strong points
> 'LUHFWLYH&(
Function > ,(&
SOCOMEC ATEX enclosures incorporate three or four pole manually operated SIDER (ND) > ,(&
load break switches which make and break on load, providing emergency breaking and > ,(&
maintenance isolation for any low voltage electrical circuit which is in an area where there is a > ,(&
risk of explosion due to dust.
> 1)&
Advantages
Safety of operations Robust design Other regulations
q Visible contacts and positive break Product has been specifically designed > 'HFUHH
indication through the operating handle and for industrial environments with the risk of Machine safety
a factory fitted mechanical flag indicator, explosion due to dust (galvanised steel,
provide guaranteed position indication of thickness 2 mm, triplex glass, S-type handle > 'HFUHHQ
the contacts. metal padlocking lever). IURP
q Double locked door when switch is in the
protection of workers
ON position. Protection degree IP65 > 'HFUHHQ
q Triple locking of the handle in the OFF Protection degree of ATEX enclosures is IP65.
IURP
position. > 'HFUHH
machine compliance
Inductive load breaking (AC23)
ATEX enclosures are designed for use with
inductive loads and are able to make and
break on load (AC23).
Specific requests
> 62&20(&FDQRIIHU
customised solutions to meet
your specific requirements.
Please contact your
Socomec office for further
information.
General characteristics
Breaking device: Enclosure: Connection:
q All safety enclosures are equipped with load q Enclosures are made of a 2 mm thick q Steel safety enclosures are available with
break switches that provide visible, reliable galvanised steel. They are assembled by bottom cable entry and exit.
indication of the contacts open position. welded and deburred. q Enclosures are fitted with a top roof and a
q SIDER for 50 A, 80 A and 630 A ratings q The anti-corrosion protection is achieved bottom closing plate in the bottom part.
q SIDER ND 80 A (6P) to 400 A ratings using an epoxy polyester powder which q Connection is achieved by running cables to
q They make and break under load polymerises in the oven at 180. Paint SGDSNOSDQLHM@KRENQ @MC Q@SHMFR
conditions and provide safety isolation for coating is 60 m minimum and colour is For higher ratings, a copper bottom-bottom
any low voltage circuit. They are factory metallic gray. busbar enables easy connection of incoming
fitted with a mechanical flag indicator q The chrome-plated zamak door is cables.
(SIDER) which provides guaranteed assembled on an invisible hinge and is
position indication of the contacts. locked using an 8 mm square key.
q Wall mounting is achieved using 4 fixing lugs Miscellaneous:
Mechanical flag indicator: (factory mounted). q Two earthing bars for connection are
q As far as I am aware this option is only available in the enclosure.
possible with SIDER and not the SIDER ND. q Fuse protection screen.
If we are utilising both switch types, and the Visible breaking:
ND cannot have a flag indicator, then we q The contacts are visible through a triplex
need to advise this. This is why I made the window, located on the enclosure door. This
point to the right (mechanical flag indicator enables the operator to confirm the position
(SIDER)). Please just confirm this point. of the contacts either during a preventative
check or before an operation.
Double locking:
q This function is achieved through a simple Operation handle:
and robust mechanism using an extension
q ATEX enclosures are provided with a red
shaft. Activation with the door open remains
S-type operating handle. It is made of an
possible by authorised personnel.
insulating material and includes a metal
padlocking lever. The handle can be locked
in the OFF position using three padlocks.
References
Bottom/bottom connection
Rating (A) No. of poles Reference
50 3P 3V41 3005
50 4P 3V41 4005
80 3P 3V41 3008
80 4P 3V41 4008
80 6P 3V41 6008
125 3P 3V51 3012
coff_280_b_1_cat
Accessories
ATEX cable glands
Black polyamide
Max. cable diameter Cable gland Locknut
Diameter (mm) Min. cable diameter (mm) (mm) Reference Reference
12 3.5 6 3240 1012 3240 3012
16 5 8 3240 1016 3240 3016
coff_283_a_1_cat
16 6 10 3240 1017
20 8 13 3240 1020 3240 3020
20 10 15 3240 1021
25 13 19 3240 1025 3240 3025
32 18 25 3240 1032 3240 3032
40 24 32 3240 1040 3240 3040
50 29 38 3240 1050 3240 3050
Crude brass
Max. cable diameter Cable gland Locknut
Diameter (mm) Min. cable diameter (mm) (mm) Reference Reference
12 3 6.5 3240 2012 3240 4012
coff_329_a_1_cat
Characteristics
Dimensions
H
B1
Ab
coff_289_c_1_fr_cat
(1) 50 400 A: 45 mm
L (1) P
630 A: 61 mm
Bottom/bottom connection
Max. connection
Rating (A) No. of poles H x W x D (mm) cross-section (mm2) Ab (mm) B1 (mm) Weight (kg)
50 3/4 P 350 x 225 x 150 16 288 198 8.2
80 3/4 P 350 x 225 x 150 35 288 198 8.4
80 6P 500 x 425 x 200 35 288 198 25
125 3/4 P 500 x 425 x 200 120 225 15
160 6P 500 x 425 x 200 120 242 275 25
200 3/4 P 500 x 425 x 200 120 242 275 21.5
400 3/4 P 700 x 500 x 250 2 x 150 340 385 34.5
630 3/4 P 700 x 500 x 300 2 x 300 262 313 47
The switching market is a highly To ensure optimal functional safety, all Glossary for IEC 60947-6-1
& solutions
Typical applications
Source transfer Earthing
Solution enabling manual or automatic Earthing of equipment such as motors or
switching between two sources, either electrical lines whilst isolating them from
transformer or generator (fig. 1). their power supply in a fail-safe way (fig. 2).
SITE 493 A
Fig. 1 Fig.2
Switching of the power supply from one inversion of the succession of phases
load to another in order to guarantee supplying a motor in order to modify the
redundancy and balancing of the operating direction of rotation (fig. 4).
time for the two loads (fig. 3).
SITE 483 A
Fig. 3 Fig.4
COFF_305_B_1_CAT
COFF_339_A_2_CAT
component.
p. 630
coff_299_a_1_cat
Strong points
Conformity to standards
Function Advantages
> IEC 60947-6-1
Manually operated polyester enclosed On load operation (AC22/AC23)
> IEC 60364
changeover switches provide changeover, Manual changeover enclosures are designed
source inversion or switching under load for operation on load and are able to make > IEC 61439
between two low voltage power circuits, as and break mixed/inductive loads (utilisation > EN 60204-1
well as their safety isolation. The enclosure categories AC22/AC23).
provides protection against contact with live Robust product
parts as well as environmental factors such as Products have been designed for severe
dust, water and other hazards. industrial conditions with chemical, pollution
or atmospheric corrosion risks.
COMO C range
General characteristics References
q Adapted to environments subject to Rating No. of Switching
chemical, dust, contamination and (A) poles type A (mm) B (mm) Reference
atmospheric corrosion risks. 25 3P I - II 135 135 4221 3C02
q Operation handle: Red/yellow handle 25 4P I - II 135 135 4221 4C02
25 3P I - 0 - II 135 135 4231 3C02
q Protection degree: IP65.
coff_339_a_2_cat
SIRCOVER range
References
Top/Bottom
connection
I - 0 - II
Rating (A) No. of poles Reference
125 3P 4215 3012
125 4P 4215 4012
160 3P 4215 3016
160 4P 4215 4016
250 3P 4215 3025
coff_299_a_1_cat
Ah
Z
q Protection degree: IP55 / IK 10.
q Colour: RAL 7030 (range < 400 A), RAL 9002
Q@MFD
N
H
coff_298_b_1_cat
Strong points
(key supplied).
q Cable gland plate: top and bottom. q Miscellaneous: 2 earth connection points,
q Material: XC steel, thickness 1.5 mm. double door locking.
References
Top/Bottom
connection
Rating (A) No. of poles Reference
63 3P 4413 3006
63 4P 4413 4006
80 3P 4413 3008
80 4P 4413 4008
100 3P 4413 3010
100 4P 4413 4010
Dimensions
348
300
105.5
300
258
coff_317_a_1_x_cat
105.5
150 58
ONKXDRSDQONVCDQQ@MFD
q Wall mounting: 4 mounting brackets supplied
(not mounted).
H
N
coff_305_b_1_cat
Single-phase ATyS M 3s Three-phase ATyS 3s
in polycarbonate enclosure in steel enclosure
Strong points
order II
position I
position O
position II
(DPS) enabling transfer to all three positions when impulse can be of infinite duration
either of the two power supplies is present. device returns to zero position, if
without causing any disturbance. power supply is available.
- A zero command drives the device
into position 0, irrespective of the
status of the I and II commands.
svrmo_079_b_1_gb_cat
order I order I
atys_024_a_1_gb_cat
order 0 order 0
order II order II
position I position I
position 0 position 0
position II position II
References
Single-phase ATyS M 3s model (2P)
Rating (A) Reference
40 1823 2004
63 1823 2006
80 1823 2008
100 1823 2010
125 1823 2012
160 1823 2016
Accessories
Dimensions
305 150
q Weight: 5.5 kg.
q Connection: recommended cable size
(Cu): 25 to 70 mm2 according to rating
(maximum size of a cable: 70 mm2).
410
atysm_208_a_1_x_cat
References
Three-phase ATyS M 3s model (4P)
IP 3X IP 54
Rating (A) No. of poles Reference Reference
40 4P 1823 4004 1823 4005
63 4P 1823 4006 1823 4007
80 4P 1823 4008 1823 4009
100 4P 1823 4010 1823 4011
125 4P 1823 4012 1823 4013
160 4P 1823 4016 1823 4017
Accessories
Description Reference
Auxiliary contact (1) 1309 0001
Voltage sensing and power supply tap (2 per reference) (1) 1399 4006
Solid neutral kit (2) 1309 9008
Kit IP54 (for IP3X enclosure conversion) 1399 4016
Power connection terminals (1) 1399 4017
(1) For more details please refer to the ATyS M section of this catalogue.
(2) Solid neutral kit provides a maintained connection between both incoming and outgoing neutral terminals,
thereby providing an unswitched neutral.
Dimensions
q Weight (without accessories): 15 kg.
q Connection (without power connection
terminals): min. Cu 6 mm, max. 70 mm.
atysm_210_a_1_x_cat
600
560
References
Standard device - 230 VAC
Rating (A) No. of poles Reference
125 4P 1723 4012
160 4P 1723 4016
250 4P 1723 4025
400 4P 1723 4040
630 4P 1723 4063
800 4P 1723 4080
1000 4P 1723 4100
1250 4P 1723 4120
1600 4P 1723 4160
2000 4P 1723 4200
2500 4P 1723 4250
3200 4P 1723 4320
Accessories
Factory fitted
Description Reference
Dual power supply 1599 9001
2nd auxiliary contact: from 125 to 630 A 1599 9002
2nd auxiliary contact: from 800 to 1600 A 1599 9012
Autotransformer 400/230 VAC for three-phase networks without neutral see ATyS pages
Terminal shrouds see ATyS pages
3 position padlocking (I-0-II) 1599 9003
Customer fit
Description: Conducting neutral Reference
125 160 A 1599 1006
250 A 1599 1025
400 A 1599 1040
630 A 1599 1063
800 A 1599 1080
1000 A 1599 1100
1250 A 1599 1120
1600 A 1599 1160
Dimensions
M
W D
3
H
N
223
atys_619_d_1_gb_cat
10.5
Z1 (1) Wall mounting brackets supplied up to 400 A.
Z2 (2) Floor standing feet from 630 A
1 (increase the height (H) by 200 mm).
(3) Riser.
12.5
2
Recommended
connection
Rating (A) cross-section (mm2) H (mm) W (mm) D (mm) M (mm) N (mm) Z1 (mm) Z2 (mm) Weight (kg)
125 50 650 400 300 448 608 38 134 25
160 70 650 400 300 448 608 38 134 25
250 120 1000 650 475 698 958 39.5 134.5 45
400 240 1000 650 475 698 958 39.5 134.5 50
630 2 x 185 1000 650 475 53 190 70
800 2 x 240 1200 800 660 66.5 253.5 135
1000 4 x 150 1200 800 660 66.5 253.5 140
1250 4 x 185 1600 1000 830 66.5 253.5 270
1600 4 x 240 1600 1000 830 67.5 253.5 375
2000 8 x 150 2000 1000 1000 400
2500 8 x 185 2000 1000 1000 400
3200 8 x 240 2000 1000 1000 400
Strong points
Function
> Dedicated solution.
q Automatic Transfer Switch Equipment q From 250 to 3200 A, enclosures are
(ATSE) in enclosures provides an equipped with ATyS 6e 4P (extended > A complete range of
autonomous and complete management in control system) with a back-to-back switch configurations.
the continuity of the power supply to critical configuration, providing a more compact > Robust product.
loads. device and enabling easier connection. > Easy integration.
q From 40 to 160 A, enclosures are equipped
with ATyS M 6s (2P/4P - Simplified control
system) or ATyS M 6e (4P - extended Conformity to standards
control system), which are modular units
enabling optimised integration. > IEC 61439-2
> IEC 60947-6-1
> IEC 60947-3
Advantages
> BS 60947-6-1
Dedicated solution A complete range of configurations
The integrated ATSE has been designed The ATSE range is available in polycarbonate
and tested to provide a reliable, safe and or steel enclosures.
autonomous solution that is easy to install
and commission.
Configuration
ATyS M 6s ATyS M 6e
atysm_030_c
atysm_031_b
atysm_203_a
q Common points between the three-phase and single-phase versions: q Applications: Transformer/Genset, Transformer/Transformer, with or
- 2 potentiometers (normal supply loss and return time delays) without priority.
- 2 dip-switches (Pause for 2 seconds in position 0 during switching I<->II ; q Display + keyboard (Device configuration; Displays supply measurements; Test
Transformer/Transformer or Transformer/Genset application). and control mode access).
q 4 LEDs (Source availability indicators; "AUT" Automatic mode; Fault). q LEDs (Product Power On ; Source availability indicators; Position indication;
q 3 inputs for external control (Inhibition of the automatic mode; Remote test on "AUT" Automatic mode; TEST/CONTROL Mode ; Fault).
load (Priority selection for Transformer/Transformer); Manual retransfer from q 3 configurable inputs.
the alternate supply to the normal supply). q 3 configurable output relays.
q 1 NO bi-stable output relay for generator start /stop command (30 VDC / 2 A). q 1 configurable bi-stable output relay for generator start /stop command (30
q 1 NC relay for product availability (250 VAC / 0.5 A). VDC / 2 A).
q Specific to the three-phase ATyS M: q Connection of a remote interface ATyS D10 or D20.
- 2 additional potentiometers (Nominal voltage; Voltage/frequency thresholds) q RS485 MODBUS communication (COM version).
- 2 additional dip switches (50 or 60 Hz; network selection)
q Specific to the single-phase ATyS M:
/1&ATSSNMUNKS@FD@MCMNLHM@KEQDPTDMBX@TSNBNMEHFTQ@SHNM
On ATyS 6e models
Operation Characteristics
ATyS 6e q Single phase or three phase control of networks I and II.
ATyS 6e are equipped with 2 power inputs (same
q Independent adjustable over/undervoltage and over/under frequency
as ATyS 3e): one for supply from power source 1
SGQDRGNKCR
NESGDMNLHM@KU@KTD
and the other for supply from power source 2.
q Adjustable hysteresis thresholds linked to the threshold values.
They allow the device to be controlled electrically
q Control of phase rotation.
atys_032_c
References
Single-phase ATyS M 6s model (2P): 230 VAC network
Rating (A) No. of poles Reference
40 2P 1854 2004
63 2P 1854 2006
80 2P 1854 2008
100 2P 1854 2010
125 2P 1854 2012
160 2P 1854 2016
Accessories
Dimensions
305 150 q Weight: 5.5 kg.
q Connection: recommended cable size
(Cu): 25 to 70 mm2 according to rating
(maximum size of a cable: 70 mm2).
410
atysm_208_a_1_x_cat
Accessories
Dimensions
q Weight (without accessories): 15 kg.
q Connection (without power connection
terminals): min. Cu 6 mm, max. 70 mm.
600
560
atysm_210_a_1_x_cat
References
Standard device - 230 VAC
Rating (A) No. of poles Reference
125 4P 1763 4012
160 4P 1763 4016
250 4P 1763 4025
400 4P 1763 4040
630 4P 1763 4063
800 4P 1763 4080
1000 4P 1763 4100
1250 4P 1763 4120
1600 4P 1763 4160
2000 4P 1763 4200
2500 4P 1763 4250
3200 4P 1763 4320
Accessories
Factory fitted
Description Reference
2nd auxiliary contact from 125 to 630 A 1599 9022
2nd auxiliary contact from 800 to 1600 A 1599 9032
Autotransformer 400 / 230 VAC for three-phase networks without neutral see ATyS pages
Terminal shrouds see ATyS pages
3 position padlocking (I-0-II) 1599 9003
Customer fit
Description Reference
Solid neutral 125 160 A 1599 1006
Solid neutral 250 A 1599 1025
Solid neutral 400 A 1599 1040
Solid neutral 630 A 1599 1063
Solid neutral 800 A 1599 1080
Solid neutral 1000 A 1599 1100
Solid neutral 1250 A 1599 1120
Solid neutral 1600 A 1599 1160
ATyS D10 1599 2010
ATyS D20 1599 2020
RJ45 connecting cable 1599 2009(1)
RS485 MODBUS communication module 1599 2000
2 inputs / 2 outputs module 1599 2001
(1) Necessary to connect an ATyS D10 or D20.
Dimensions
M
W D
3
atys_621_c_1_gb_cat
H
N
280
Z1
Z2
1 (1) Wall mounting brackets supplied up to 400 A.
(2) Floor standing feet from 630 A (increase the height (H) by 200 mm).
12.5 (3) Interfaces ATyS D10 or D20 (optional).
2
Recommended
connection
Rating (A) cross-section (mm2) H (mm) W (mm) D (mm) M (mm) N (mm) Z1 (mm) Z2 (mm) Weight (kg)
125 50 650 400 300 448 608 38 134 25
160 70 650 400 300 448 608 38 134 25
250 120 1000 650 475 698 958 39.5 134.5 45
400 240 1000 650 475 698 958 39.5 134.5 50
630 2 x 185 1000 650 475 53 190 70
800 2 x 240 1200 800 660 66.5 253.5 135
1000 4 x 150 1200 800 660 66.5 253.5 140
1250 4 x 185 1600 1000 830 66.5 253.5 270
1600 4 x 240 1600 1000 830 67.5 253.5 375
2000 8 x 150 2000 1000 1000 400
2500 8 x 185 2000 1000 1000 400
3200 8 x 240 2000 1000 1000 400
Strong points
tablo_035_a_1_cat
tablo_036_a_1_cat
General characteristics
q From 40 to 3200 A - 4 poles. q AUTO / MANU selector.
q 230/400 VAC +/- 20%, 50/60 Hz, q Equipment protection degree: IP41 as
self-supplied from incoming sources. standard - Other IP upon request.
q Normal/Emergency logic control sequence. q Hinged door.
q Voltage and frequency checking of q 6@KKLNTMSHMFAQ@BJDSRRTOOKHDCTOSN
networks I and II. q Floor standing feet from 250A to 3200 A.
q Control of phase rotation. q Plug-in ATS from 160 A.
q 1 configurable output relay for generator q Phase identification.
start/stop command. q Mimic panel (3 LEDs; source availability
q Position I, 0, II control by external dry (1 and 2) and load; 16 LED mimic panel
contact. optional).
q Manual emergency operation. q Integral protection against direct contact on
q Auxiliary contacts. each functional unit.
q MODBUS communication q Steel enclosure
(factory fitted). q Colour: RAL 7035.
2 versions
Single Line ATS Bypass Double Line ATS Bypass
q It consists of 2 functions: an automatic changeover switch and a q It consists of 3 functions: an automatic changeover switch, an ATS
single Bypass line connected to the preferred supply source. Bypass and a facility for selecting between supply sources when in
Bypass.
Disconnectors
Disconnectors
Automatic Transfer Q2
Automatic Transfer Switch
Q2
Switch
Disconnectors
Disconnectors
Overlapping Function Q1
Overlapping Function Q1
Selection Source Q3
atys_800_a_1_gb _cat
atys_801_a_1_gb _cat
Load Load
Use
Normal Position: Bypass position: Test Position:
q The load is supplied by the supply source q ATS seamless transfer to the Bypass mode q From the Bypass position, changeover
defined as the preferred source. In is achieved using the bypss line via Q1 to switch Q2 can be closed to supply the
case of primary source failure, the ATS ensure continuity in the power supply to ATS and achieve operational checks,
automatically transfers the load to the the load. Changeover switch Q2 is then without jeopardizing the supply to the load.
alternate source when available. open to provide complete isolation from the Transfer to the normal position can then be
power supply sources and to ensure safe achieved.
interventions.
References
Standard product - 230 VAC for ATyS M 6e Standard product- 230 VAC for ATyS 6e
Single Line Double Line Single Line Double Line
Rating (A) No. of poles Reference(1) Reference(1) Rating (A) No. of poles Reference(1) Reference(1)
40 4P 1785 4004 1786 4004 160 4P 1785 4016 1786 4016
63 4P 1785 4006 1786 4006 250 4P 1785 4025 1786 4025
80 4P 1785 4008 1786 4008 400 4P 1785 4040 1786 4040
100 4P 1785 4010 1786 4010 630 4P 1785 4063 1786 4063
125 4P 1785 4012 1786 4012 800 4P 1785 4080 1786 4080
(1) Network 127/230 VAC, on request. 1000 4P 1785 4100 1786 4100
1250 4P 1785 4120 1786 4120
1600 4P 1785 4160 1786 4160
2000 4P 1785 4200 1786 4200
2500 4P 1785 4250 1786 4250
3200 4P 1785 4320 1786 4320
(1) Network 277 VAC, on request.
Accessories
Customer fit
Description Reference
2 inputs / 2 outputs module (ATyS 6e only) 1599 2001
Extension cabinet
Use
From 1250A to 3200 A, the standard enclosed ATS Bypass is supplied with connections to
allow for Bottom/Bottom or Bottom/Top cable entry.
In order to facilitate the wiring, we propose the use of an extension cabinet, which can be mounted
to the side of the standard ATS Bypass enclosure, when utilising all other types of connections
(TT/TB/BT). The extension cabinet also enables any necessary future adaptation.
kdrys_504_a_2_cat
Padlockable handle in position 0 Reference
1250 2000 1599 9004
2500 3200 1599 9005
sgys_069_a_1_cat
40 125 1599 9016
250 400 1599 9017
630 3200 1599 9018
Multifunction meter
Use
Multifunction meters are now available for For more information, please see pages
the display and monitoring of all the electrical 436 to 460.
parameters.
diris_750_a_1_cat
Engine Exerciser
Use
The enclosed ATS Bypass can be supplied with a genset exerciser.
(configure generator Start/Stop times, enable/disable routines, etc....).
access_276_a_1_cat
Description Reference
Engine Exerciser 1599 9006
Tinned Busbars
Use Description Reference
250 1599 9007
Tinned busbar option for severe
400 1599 9008
environmental conditions.
630 1599 9009
800 1599 9010
1000 1599 9011
1250 1600 1599 9013
2000 1599 9014
2500 3200 1599 9015
atys_761_a_1_fr_cat
Alarm
Signalling
Use LOAD
To get a global overview of the system status, an optional 16 LED mimic panel is available (voltage Q3
availability per phase and device positions). P2 P1
Q2
ATS
Mimic panel S2 S1
acces_275_b_1_x_cat
Single Line Double Line
Description Reference Reference
40 3200 1599 9033 1599 9034 Q1
Normal By-Pass
S2 S1
Dimensions
from 40 to 160 A
M W 12.5 D
W 12.5 D
0
P2 P1
0
P2 P1 D 20
D 20 Q3
H
Q3
N
H
0 OFF
Normal By-Pass ON
atys_759_c_1_gb_cat
atys_749_c_1_gb_cat
0 OFF
Normal By-Pass ON
Q1 Q2
Q1 Q2
The photovoltaic market is a highly It is therefore imperative to call on the skills Did you know?
& solutions
demanding one in terms of safety and quality. of a specialist to guarantee installations are
Within the space of a decade, it has gone as safe, durable and efficient as possible. For further information, consult our
from an experimental to an industrial stage, Its expertise in photovoltaic technology Photovoltaic Application Guide
which requires professionalisation based on enables SOCOMEC to demonstrate which can be found on our site
the standardization of components, their use the application of its experience in the www.socomec.com
and the rules for installation. search for solutions to optimise electrical
installations and combine this with
environmental protection.
Network
and all or some of this energy can be
reinjected into the national grid when the
on-site energy demands are low. When Production Conversion Connection to
mains network
local demand is greater than the energy
produced by the PV installation, the local
supply is then topped up by the national Multi-inverter installations
grid.
This architecture is designed for high-power industrial installations from a few hundred
kWc to several MWc. If there is a fault or maintenance is required, the loss of production is
q Isolated standalone installations limited to the machine in question.
These are designed to operate
independently of the national grid. They q Individually managed multi-inverter installation
can be combined with another energy This architecture is used to reduce the power of the PV inverters, splitting the PV
source (wind, generators, etc.), to form a generators and inverters over several lines.
"hybrid photovoltaic" installation.
CATEC-PV_054_A_GB
AC Connection to
protection mains network
Production DC Conversion
protection
AC Connection to
CATEC-PV_055_A_GB
Conversion
Production DC
protection
Main functions
Photovoltaic generator DC side, Inverter
q PV panels. upstream of the inverter DC/AC converter
q Switching and breaking. q Conversion of the
q Short circuit and voltage DCcurrent produced by
surge (lightning) protection. the photovoltaic panels
q Integration in double into AC current.
insulation (Class 2 q Automatic disconnection
components). (loss of insulation, mains
power, etc.).
COFF-PV_068_A
Strong points
Enclosure
selection
Safety
Connection
2 device 3
type
selection
Switching
device
selection
1
Select the enclosure in relation to its environment
Environment Steel enclosure Polyester enclosure Stainless steel enclosure ATEX enclosure
Chemical damage q q
Mechanical risks q q q q
Risk of dust q q
Risk of contamination q q q q
Atmospheric corrosion q q
Risk of explosion due to dust q
2 3 4
Define mode of connection Select the switching device Select the safety device
q HH: Top cable input and output. q Load break switches, fuse combination q Double locking
q HB: Top cable input and bottom switches, changeover switches, etc. q Positive break indication or visible breaking.
cable output. q Rating of 16 to 5000 A. q Mechanical indicator.
q BB: Bottom cable input and output. q -TLADQNEONKDRONKDRNQ7ONKDR q Locking system and interlock devices.
for a specific design.
q Types of operation handle: Direct or
External; Front (centred or not) or Side.
> Draw up the specifications and technical characteristics describing the application and the electrical properties
required, as well as your expectations in terms of equipment functions.
On this basis, SOCOMEC will define the best solution for your application.
appli_372_a
appli_372_a
coff_145_c_1_cat
coff_044_b
coff_393_a
coff_125_a_3
coff-pv_088_a
coff-pv_087_a
tablo_039_a
tablo_020_a
coff_392_a
tablo_021_a
ERDF type transformer station Low voltage switchgear distribution panels,
Cabinets and enclosures for transformer stations
distribution cabinets
(UA95, UA98, CERT TR/AR/TT/TC enclosures, current short-circuiting Long-term specialist integrator in low voltage distribution with support
device, etc.) SOCOMEC is the original manufacturer and official supplier of throughout the study process. Manufacture according to various
RTE/ERDF (French Public Electricity Company). format and service indices. Emphasis on fuse protection solutions with
optional fault finding depending on the neutral systems used.
dp_008_a
tablo_017_a
tablo_025_a
ua_005_b
dp_020_a
Non contractual document. 2013, Socomec SA. All rights reserved. - To help protect the environment, this document has been printed on PEFC paper (Programme for the Endorsement of Forest Certification)
Tel. +49 (0)7243 65 29 2 0 Tel. +91 124 4027210
info.scp.de@socomec.com info.scp.in@socomec.com
ITALY
I - 20098 San Giuliano Milanese (MI)
Tel. +39 02 9849821
info.scp.it@socomec.com
NEThERLANDS
NL - 3991 CD Houten
Tel. +31 (0)30 760 0901
info.scp.nl@socomec.com
POLAND
01-625 Warszawa
Tel. +48 91 442 64 11
info.scp.pl@socomec.com
SLOVENIA
SI - 1000 Ljubljana
Tel. +386 1 5807 860
info.scp.si@socomec.com
SPAIN
E - 08329 Tei (Barcelona)
Tel. +34 93 540 75 75
info.scp.es@socomec.com
TURKEY
34775 Istanbul
Tel. +90 (0)216 540 71 20
info.scp.tr@socomec.com
www.socomec.com