Warning 6 Output connector Output signal interface for valve manifold Installation (Continued) Setting
Bus statusspecific and SI unitspecific LEDs
Do not disassemble, modify (including changing the printed circuit 7 LED and switch Switches for setting of node address and Connecting cables PROFIBUS DP address setting and Fail safe setting (SETTINGS)
board) or repair. operating mode <PROFIBUS DP address setting (ADDRESS)>
Select the appropriate cables to mate with the connectors mounted on the
An injury or failure can result. 8 Mounting hole Mounting hole for connection to the valve manifold The PROFIBUS DP address is binary coded and can be set from 1 to
SI unit.
Do not operate the product outside of the specifications. 125 using the 8-element switch.
Do not use for flammable or harmful fluids. Accessories Fieldbus interface connector layout Note: Factory default setting is Address 1.
Fire, malfunction, or damage to the product can result. <Fail safe setting (OUTPUT STATE)>
Hexagon socket head cap 2 pcs. M3x30 screw for connection to the valve <EX260-SPR1/-SPR2/-SPR3/-SPR4>
Verify the specifications before use. screw manifold Set the reaction of outputs to the communication error.
Do not operate in an atmosphere containing flammable or BUS OUT: M12 5-pole socket B-coded CLEAR: Clear all outputs.
1 pc. seal cap for unused fieldbus interface HOLD: Hold the last state before communication error.
explosive gases. Seal cap No. Designation Description
connector (BUS OUT) 1 Note: Factory default setting is CLEAR.
Fire or an explosion can result.
4 5 2
1 - Unused
This product is not designed to be explosion proof. Note: Seal cap will be required only for EX260-SPR1/-SPR2/-SPR3/-SPR4.
2 RXD/TXD-N Receive/transmit data, negative
If using the product in an interlocking circuit: 3
Provide a double interlocking system, for example a mechanical 3 - Unused
ON 1 2 3 4 5 6 7 8
system. 4 RXD/TXD-P Receive/transmit data, positive
Check the product regularly for proper operation. 5 - Unused Note: Be sure to switch off the power supply before setting the switches.
Otherwise malfunction can result, causing an accident.
BUS IN: M12 5-pole plug B-coded 0: OFF, 1: ON
The following instructions must be followed during maintenance:
Turn off the power supply. No. Designation Description No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8
Switch No
3
Stop the air supply, exhaust the residual pressure and verify that the 1 - Unused 64 32 16 8 4 2 1
4 5 2
air is released before performing maintenance. 2 RXD/TXD-N Receive/transmit data, negative 1 0 0 0 0 0 0 1
Otherwise an injury can result. 1 2 0 0 0 0 0 1 0
3 - Unused
Caution 4 RXD/TXD-P Receive/transmit data, positive ADDRESS
3
-
0 0 0 0 0 1 1
5 - Unused 4 0 0 0 0 1 0 0
After maintenance is complete, perform appropriate functional : : : : : : : :
inspections. : : : : : : : :
Stop operation if the equipment does not function properly. 125 1 1 1 1 1 0 1
Safety cannot be assured in the case of unexpected malfunction.
OUTPUT CLEAR 0 -
Provide grounding to assure the safety and noise resistance of the
STATE HOLD 1 -
Fieldbus system.
Individual grounding should be provided close to the product with a
short cable.
NOTE
When conformity to UL is necessary the SI unit must be used with a
UL 1310 Class2 power supply.
EX260-TFN20