You are on page 1of 2

A-141, EPIP, RIICO Industrial Area, Neemrana, Rajasthan, India

CERTIFICATE OF ANALYSIS
Department : Quality Control
Title : Riboflavin
Batch No. : UQ40910196 AR.No. : XL/RM/15/008
Qty. Received : 275 Kg Mfg. Date : 09/14
Date of Receipt : 02/11/2015 Exp.Date : 09/17

Manufactured By : DSM Nutional Products Asia Pacihc


Supplied By : K. Sevantilal & co. Thane
Date of Report : 28/11/2015 Sample. Qty. : 100 g
GRN. No. : RM-011 Page : 1 of 2

S. No. Tests Specifications Results


A white or almost white, crystalline powder
01 Description Complies
or colourless crystals
02 Solubility Freely soluble in water and in ethanol. Complies
First identification: A, B
03 Identification Complies
Second identification: A, C, D
3A Melting point 128 C to 131 C.
The infra red absorption spectrum of the
3B By IR sample should correspond to the similarly Complies
obtained spectrum of standard.
Ammonia should evolve which should
3C By Chemical Complies
recognisable by its odour.
3D By Chemical A yellow colour should develop. Complies

04 pH* 6.0 to 7.5 6.8


Any spot in the chromatogram obtained
with the test solution, apart from the
05 Related Substances principal spot, should not more intense than Complies
the spot in the chromatogram obtained with
the reference solution
06 Heavy metals* NMT 30 ppm < 30

07 Loss on drying Not more than 0.5 % 0.75%

Prepared By Checked By Approved By

Sign

Date
Department Quality Control Quality control Head QC
Format No.QC37/F01-00
A-141, EPIP, RIICO Industrial Area, Neemrana, Rajasthan, India
CERTIFICATE OF ANALYSIS
Department : Quality Control
Title : Riboflavin
Batch No. : UQ40910196 AR.No. : XL/RM/15/008
Qty. Received : 275 Kg Mfg. Date : 09/14
Date of Receipt : 02/11/2015 Exp.Date : 09/17

Manufactured By : DSM Nutional Products Asia Pacihc


Supplied By : K. Sevantilal & co. Thane
Date of Report : 28/11/2015 Sample. Qty. : 100 g
GRN. No. : RM-011 Page : 2 of 2

S. No. Tests Specifications Results

08 Sulfated Ash NMT 0.1 % 0.05%


Assay (Dry
09 99.0 to 101 % 99.53%
Substance)
Remarks: Sample complies / Does not complies as per Specification No. SPC/RM/014-00