Professional Documents
Culture Documents
SPPA-T2000
Innovations
External
Network
OPC
OT OT OT OT/ET OT/DT web-server
Terminal Bus
OM ES DS
Plant Bus
Automation AP AP AP AP CM
Aux. SIMATIC
System S5 / S7
APF AG-F APT IEC 60870
Modbus
PROFIBUS-DP
PROFIBUS-PA AS-Interface
SIM Actuator/
ET200M Control Switchgear DP/PA DP/AS-i
Valve Link Link
(APF) (AG-F)
AP CM
One common System Platform SIMATIC
S5 / S7 IEC 60870
with SIMATIC S7 Modbus
APF AG-F SIMADYN
for all Automation Functions
Add
FUM FUM-F SIM-F FEM ET200M
PROFIBUS-DP
AP CM-S7
SIMATIC
S7- S7- S7- S7 IEC 60870
400FH 300 F 400 H Modbus
FUM Add
ET 200M FEM ET200M
PROFIBUS-DP
AP AP
FUM FUM
Marshalling Switch
Cabinet Gear
Field/ SIM
Junction Equipment M
Single
Box Cables Rooms M
M Remote Intelligent
M I/O Field Device
AP AS AP
620
Field Bus
SIMATIC S5 DCS Room PROFIBUS-DP SIMATIC
SIMATICS7S5
One Bussystem
PROFIBUS
FUM to integrate
FUM FUM FUM
all
different I/O
Multi Conductor Field Bus
Cables PROFIBUS-DP
Systems
and
Field Devices
Marshalling
Cabinet
Switch
Gear
FUM FUM
Field/ SIM
Junction Equipment M
Single
Box Cables Rooms M
M FUM SIM Intelligent
M Function Module Signal Modules Field Device
PU-S5 SU ES ES/DS-Server
DS PU-S7
AP AP
SIMATIC S5 CM SIMATIC S7 CM-S7
M M
PROFIBUS-DP PROFIBUS-DP
SIM SIM
M DP/PA M DP/PA
Link Link
Web-Client
PU-TME PU-S7
GET with Web-Server SU ES with Web-Server ES/DS-Server
CS 275
AP
AS 220 SIMATIC S7 CM-S7
IEC 60870
TME-IO FUM Modbus
PROFIBUS-DP
SIM
M DP/PA
Link
web4txp
2
AP AP
AS 220 SIMATIC S5 SIMATIC S7
PROFIBUS-DP PROFIBUS-DP
CPU-Type
4 Onboard Interfaces
Swappable
2 Sync-Modules for redundancy
Sync-Module
coupling with fiber optic
1 PROFIBUS DP Master
interface for periphery (FUM,
Fiber Optic Link SIM, intelligent field devices)
Plant Bus
1 2 3 4 5 6 7 8 9a 1 2 3 4 5 6 7 8 9b
1 2 Power Supply
6 CP 443-5 PROFIBUS DP
Master
7 CP 443-5 PROFIBUS DP
Master
8 CP 443-5 PROFIBUS DP
Master
9a SM 421 Digital Input
9b SM 422 Digital Output
PROFIBUS DP
Line 1 2 3 4 1 2 3 4
Plant Bus
Redundant AP
(SIMATIC S7)
AP
SIMATIC S7
FUM
FUM FUM
FUM
FUM - subrack
FUM FUM
(19 modules)
FUM typical typical
2 FUM subracks 2 FUM subracks
FUM
typical
4 FUM subracks max. 6 FUM- subracks per AP allowed
Copyright Siemens AG 2007. All rights reserved.
Page 12 March-2007 Andreas Lang Power Generation / Instrumentation & Controls / PG L5
Automation with the highest accuracy
Time resolution 1 ms
Plant bus
PROFIBUS-DP
Option: FUM 210GB-I
Time accuracy
system wide 6 ms
FUM FUM FUM
Time resolution
(typical)
1 ms
AP
SIMATIC S7
DP/AS-i
Link
AS-interface
External
Network
OPC
OT OT OT OT/DT ET/DT web-server
Plant Bus
PROFIBUS-DP
Switch (SCALANCE)
Star Coupler Switch Module (OSM/ESM)
1 GBit/s virtual Ring
10 MBit/s virtual Ring 100 MBit/s virtual Ring
Load Limiting