A shortcut to energy savings

Advantages of infinitely variable speed adjustment

Energy savings on centrifugal pumps, fans and compressors

Total cost of ownership

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Advantages of infinitely variable
speed adjustment
400 V 50 Hz

Energy savings
Process optimisation
0 400 V, 0 50+ Hz
Smooth machine operation
l s ignal
tro
Con Less maintenance
Improved working environment
0-100+% Speed Higher productivity

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Advantages of infinitely variable
speed adjustment
Energy savings (Typical load characteristics)

Winding

conveyor belts, cranes, positive


displacement pumps, compressors

rollers, smoothing machines

centrifugal pumps and fans.

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Centrifugal pumps, fans and compressors

Considerably energy savings


Short payback time
Easy retrofit
Long lifetime of the investment
No disadvantages or eliminate them

Do you need permanently 100% of the installed capacity?

no! less or more

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Simplified Brewery Refrigeration System:
Brine pump speed Constant suction pressure Condenser fan control
according to actual load
or floating pressure depending Floating head pressure control
on actual load
Set point = Wet bulb (Ambient
PID temp, RH) + 10 C

PID
Minimum 20 C

P Pe Pc

PID
Compressor
Brine pump
T+P
P
Heat exchanger

Condenser
Evaporator

Tc
M

T Throttling device

Pe Pc
Xavier Poupeleer ing. / Danfoss KAM
www.Danfoss.be/drives 5 Feb 2007
Compressors and centrifugal pumps and fans

1.Centrifugal pumps and fans

2. Compressors

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
But we already regulate the capacity of
centrifugal pumps and fans
Flow (*) Pressure
PID

(*)

PID
M M

-The motor of the pump is connected Direct Online ( DO; star-delta; softstarter )
-The pump runs continously at full speed.
-The valve adjust the flow.
Xavier Poupeleer ing. / Danfoss KAM
www.Danfoss.be/drives 5 Feb 2007
A look at the pump caracteristics

40%
50%

60%

70%
50

75%
77%

%
45

79

%
80
Total Head (Pressure)

40

%
80
%
35 79

7 5 7%
%
7
30 70
%

25 %
60
20 50
%

15
10 # diameters
5 (#)
0
0 100 200 300 400 500 600
Flow

What happens when we change the position of the valve ?

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
convensional vs frequency drive

Diagramme : flow/pressure
1 = pump curve
2 = system curve
3 = system + valve curve
4 = pump curve at lower speed
VI= pump losses
VT= valve losses
green area = guides losses
Ps= outlet power

throttle valves, bypass systems


or inlet guide vanes frequency drive

When we change the valve position we move from system curve 2 to 3. Other working point.
For the same pressure (same flow ) the needed power (colored surface) is less than the half.
Look at the pump losses, they are lower due to lower pressure in the pump.

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
convensional vs frequency drive

Transformer Transformer

Motor VSD

Pump Motor

Throttle valve Pump

Utilized output Utilized output


The utilized output at the pump is 100% in each case. In the case of throttle control, 2,86 times the
utilized power has to be fed in. With electronic speed control, in contrast 1,6 times the utilized power
has to be fed. The losses losses are reduced to 1/3
Xavier Poupeleer ing. / Danfoss KAM
www.Danfoss.be/drives 5 Feb 2007
Drives are no cost

If for example we double the speed, the flow is doubled. The pressure loss is quadrupled because the
pressure is a quadratic function of the flow. To run the machine 4 times more couple is needed.

The power is the result of the product of the couple and speed. At double speed a power X 8
corresponds!
Payback time mostly less than one year.

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Compressors and centrifugal pumps and fans

1.Centrifugal pumps and fans

2. Compressors

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Compressor capacity regulation

100
80
%Power

60
40
20
0
0 50 100
% Capacity

Throttle valve On-Off


L-NL Variable Speed
Slide valve

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Compressor capacity regulation
Reduced average system header pressure, 0,1 bar = 1%.
Pressure stability
Load / NoLoad 2 bar
Modulation 1 bar
Variable Speed Drive 0,2 bar

Bar 120
100
80
60
40
20
0
time

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Compressor capacity regulation

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Total Cost of Ownership

Expansion and upgrade Hardware


Downtime and repair Software

Set Up and Admin Cabeling


Operation Efficiency Labour

The Danfoss solution is a Hardware that eliminates or considerably reduces all other costs

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Hardware Dilemma for a drive manufacturer
Protection
Danfoss Solution

Harmonic reactors
Cabinet IPxx

RFI filter

Options
Inverter

Motor inductor (du/dt)


common mode FC-102P11KT4E66H1BGC8XXSXXXXA0BKCXXXXD0
suppression Danfoss std
Danfoss options
PLC +
Safety Cascade
Xavier Poupeleer ing. / Danfoss KAM
www.Danfoss.be/drives 5 Feb 2007
Free Software (USB-port)

Plug and play connection of a PC


Easy use of
VLT Set-up Software
MCT 10
VLT Energy Box
Syncpos MC0 305

Saves Time and money

Commissioning is Child's play

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Installation costs

Safety Cat. 3 (EN 954-1)


Stopping Cat. 0 (EN 60204-1) Buid-up options
Simple (one-wire) cabling IP00 up to IP66
No contactor on output
Free space in cabinet

Smalest footprint on the market


Smart Logic Controller Highest ambient temp.
Cascade Controller 50C-55C
Build in filters have less heat
dissipation
Save on cabinet cooling

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Operation costs
The new VLT HMI fits all VSD needs

220Vac / 400Vac / 690Vac


0,25 kW up to 1.2 mW
IP00 / IP20 / IP21 / IP55 / IP66
Global player (24/7 service)

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Comissioning and troubleshooting

My personal menu
Quick setup
Changes made
Loggings
Application set-ups
28 languages
On board manual : Brief help text
for the function in use
MCT10
Design Guide Manuals
Friendly

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
f1

Expansion and upgrade

Adaptable and programmable

Modules can be applied independently


Buy on need to have basis
Easy upgrade
Easy commissioning
Easy service
Reliability

Flexible

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Dias nummer 22

f1 C-optionen
f31685; 17-01-2006
Downtime and repair

Fact : downtime cost of Bottle line = 5000 /h

Case Stella Artois Brewery in Leuven :


No maintenance Install base : 1000 pcs
Danfoss Quality Total failures in 2006 : 32 pcs ( 3,2%)
Global 24/7 Service 50% of 32 pcs,older than 14 Years !
Service stocks (VLT3000)
Application Support 25% in critical environments (bad
Modular concept stock reduction implementation)
25% no info about at this time

Bringing the lowest cost of ownership

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Total Cost of Ownership

Std Filtering
Modular concept Build-in intelligence
IP-Range
Expansion and upgrade Hardware options
Hardware
Downtime and repair Software
Quality USB-port
Gobal 24/7 Service Free MCT10
Free Syncpos program
Free Energy Box

Set Up and Admin


IP range
Operation Efficiency Cabeling
Hardware options
One HMI Labour Highest ambient temp
Free MCT10 Small bookstyle
LCP Help Multy languages SLC / Cascade
Danfoss Manuals Safe stop

The Danfoss solution is a Hardware that eliminates or considerably reduces all other costs

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
A new generation with new standards

Reliable Intelligent

Flexible Friendly

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Hammer Mills classic

Feeding variation based

ve
C
PL

Dri
on Current consumption

ter
Rotation Detector Bypass

r
Sta

0
IP2
ft
So
50Hz

Rotation Change

Xavier Poupeleer ing. / Danfoss KAM Cabinet


www.Danfoss.be/drives 5 Feb 2007
Hammer Mills VSD

Feeding variation based Proces


on actual Torque Monitoring
Cabinet

Torque

-//-50Hz // 50Hz // +

IP5 ve
5
Dri
Xavier Poupeleer ing. / Danfoss KAM
www.Danfoss.be/drives 5 Feb 2007
Advantages of Frequency drives on
Hammer Mills

infinitely variable speed adjustment, based on different grain types (change of impulse
force on grains)
Better product quality regulation 0-50Hz or more in both directions (possible energy
savings)
Easy and Fastest direction change
Controlled stops ( high inertia 4 to 6 times rotor inertia)
Less components (rotation-, speed detection, contactors, PLC, etc.)
Feeding device regulation based on actual torque in crusher ( Current measures involves
also magnetising current, not linear )
Local cos compensation (energy savings)
No starting current peaks (energy savings, smaller transformer needed)
Exact Feeding device regulation (closed torque PID loop)
Less maintenance, longer mechanical lifetime

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007
Thanks for your attention

You are speaking

Xavier Poupeleer ing. / Danfoss KAM


www.Danfoss.be/drives 5 Feb 2007