You are on page 1of 5

ATM.

BLOW DOWN VENT


Blow down quantity kg/h 275
Blow down Enthalpy Kcal/kg 202.4
C W I/L Temp C 35
Effluent temperature C 50

Vent Steam 47 kg/h


111 C

CW I/L 17%
926 kg/h
83%

Effluent
1154 kg/h

Vent Steam kg/h 47


CW flow rate kg/h 926
Effluent Flow rate kg/h 1154
Sheet 1 of 2 Rev.1
THERMAL SYSTEMS (Hyd) Pvt Ltd., Hyderabad, A.P. India
Status ORDER

DATA SHEET FOR STEAM DRUM / NORMAL Spec No. W 714 -PC- 009

CLIENT : USHA BELTRAN LTD.,

Water flow to the Boiler : 42021 kg/h


Steam Drum Operating Pressure : 54.0 kg/cm g
Steam Drum Operating Temperature : 268.69 c
Density of Saturated water : 777.5 kg/m3
Density of Saturated Steam : 27.5 kg/m3
Steam Drum Inside Diameter : 2000 mm
Steam Drum Length (WL to WL) : 5000.00 mm
Steam Drum Total Volume : 17.79 m3
Height Between Levels in mm:
Distance between NWL to CL of Drum : 0
Distance between HHWL to CL of Drum : 175
Distance between HWL to CL of Drum : 100
Distance between NWL to LWL : 100
Distance between LWL to LLWL : 150
Distance between LWL to Empty : 900
Distance between LLWL to Empty : 750
Distance between Cl of DC to Empty : 100
Partial Volumes in cu.mtrs: Steam Loading :m3/m3h
HHWL to Empty : 10.91 222
HWL to Empty : 10.05 197
NWL to Empty : 8.90 172
LWL to Empty : 7.74 152
LLWL to Empty : 6.04 130
CL of DC to Empty : 0.31
Hold - up Time in Minutes:

HHWL TO CL OF DOWNCOMER 11.77


HWL TO CL OF DOWNCOMER 10.82
NWL TO CL OF DOWNCOMER 9.53
LWL TO CL OF DOWNCOMER 8.25
LLWL TO CL OF DOWNCOMER 6.36
HHWL TO HWL 0.95
HWL TO NWL 1.28
NWL TO LWL 1.28
LWL TO LLWL 1.89

HHWL
100 100 75

0.95 Minutes
HWL

1.28 Minutes C/LOFDRUM


NWL

1.28 Minutes
LWL
150

1.89 Minutes
LLWL

6.36 Minutes
750

Size: ID2000 mm x 5000 mm Lg

The Retention time indicated above is Upto CL of DownComer


Sheet 2 of 2 Rev.1
THERMAL SYSTEMS (Hyd) Pvt Ltd., Hyderabad, A.P. India
Status ORDER

DATA SHEET FOR STEAM DRUM Spec No. W 714 -PC- 009

CLIENT : USHA BELTRAN LTD.,

50 thk
50 thk
(nom)

2100
OD
5000 (WL to WL)

1 Design Code IBR 1950 LATEST


2 Working Pressure , kg/cm,g 54.0
3 Design Pressure , kg/cm,g 59.4
4 Working Temperature , c 268.7
5 Design Temperature , c 296.7
6 Corrosion Allowance , mm 0.75
7 Stress Relieving Yes
8 Radiography Yes
9 Test Pressure , kg/cm g 89.1
10 Shape of Head ToriSpherical
11 Inspection CIB (A.P)
12 Certification Asper Code
13
14
15 MATERIAL OF CONSTRUCTION
16
17 Shell A 516 gr 70
18 Dished End A 516 gr 70
19 Nozzles A 106 gr B
20 Flanges A 516 gr 70 / A 105
21
22
23 SERVICE DATA SIZE QTY RATING
24 DN Nr CLASS
25 Safety Valve Connection 65 2 600 #
26 Steam Outlet Connection 80 16 SCH 80
27 Aux. Steam outlet - - -
28 BFW inlet 150 1 SCH 80
29 Blow down 25 / 40 1 each SCH 80
30 Riser Stubs 80 60 SCH 80
31 Down Commer Stubs 200 / 250 4/2 SCH 80
32
33 Steam Capacity 42021 kg/h
34 Drum Total Volume 17.79 m3
35 Steam Space Loading, m3/m3-h (Upto NWL) 172 < 400 ; Hence Okay
36 Hold-up Time: HHWL TO CL OF DOWNCOMER 11.77 Minutes
37 HWL TO CL OF DOWNCOMER 10.82 Minutes
38 NWL TO CL OF DOWNCOMER 9.53 Minutes
39 LWL TO CL OF DOWNCOMER 8.25 Minutes
40 LLWL TO CL OF DOWNCOMER 6.36 Minutes
PPD CKD APPD
kg/cm(a) Deg C
Steam Pressure and temp.@ B/L 2.00 157.00

STEAM PROPERTIES: BOILER SH ECO#1

Working Pressure, kg/cm2(a)= 10.00 2.00 1.30


Saturation Temperature = 179.04 119.60 105.26
Sensible Heat (h), Kcal/Kg = 181.20 - 105.36
Latent Heat (L), Kcal/Kg = 481.80 -NA- 535.42
Total Heat (Enthalpy) (H), Kcal/Kg = 663.00 645.75 640.78
Superheated Enthalpy = -NA- 664.91 -NA-
Density, kg/m3 = 5.05 1.01 957.00

You might also like