This chapter of the PER provides an overview / summary of the proposed upgrades and improvements to
the Salisbury WWTP necessary to achieve the future enhanced nutrient removal (ENR) required by their
MDE NPDES permit, improve the operational reliability of both the liquid and solids treatment processes,
and reduce the amount of biosolids the facility must dispose of by replacing the unsafe and unreliable
dryer. The information presented in this chapter is expanded upon in chapters 3 through 21 of this PER
and additional backup / supporting material can be found in the Appendices.

2.1 Flows and Loads


BC updated the basis of design presented in the CAP as a result of the data collected during the
wastewater characterization study (Appendix A) as well as additional influent and primary effluent
complimentary data collected by plant staff. Appendix B describes the development of the flows and
loads used to develop the basis of design presented in Table 1-1. These data sets indicated that the
influent TKN-to-COD ratio used during the CAP was low compared to the actual values measured during
the wastewater characterization study. This value came from very limited historical data available at the
time. BC believes the value obtained from the wastewater characterization study is more representative
of the wastewater at the City of Salisbury WWTP. Additional samples collected over the last several
months have confirmed that the higher TKN values are correct.
There are two significant changes in the design criteria in Table 1-1 and those used in the CAP. The first
is the design AADF. After the CAP, the City of Salisbury directed BC to use 8.5 mgd for the design AADF
instead of 10.2 in the CAP, because MDE will not issue the Salisbury WWTP a permit for 10.2 mgd. The
second change is the increase in influent TKN load. After the special sampling, BC recommended
increasing the design influent TKN concentration from 36.4 mg/L to 53.8 mg/L. This increased the
influent TKN load from 3,100 pounds per day to 3,800 pounds per day.

2.2 Process Flow Diagrams


Figures 2-1 and 2-2 illustrate the overall process flow diagrams (PFDs) for the recommended liquid and
solids treatment processes, respectively. Although the recommended liquid and solids treatment
processes are essentially the same as those recommended in the CAP, the following changes should be
noted:
Conversion of the Internal Recycle Valve Vault to a junction box to blend RAS and IMLR prior to the
Internal Recycle Junction Chamber (Figure 2-1).
Removal of the internal baffle wall in the primary anoxic tanks based on modeling results that
demonstrate that separation of this zone into two tanks was unnecessary (Figure 2-1).
Providing four trains for the supplemental tanks (rather than three trains) to provide additional
redundancy and allow more of the WWTP to be in-service during annual maintenance on fine
bubble diffusers (Figure 2-1).
A fourth secondary clarifier is recommended to avoid increasing the supplemental biological tank
volume to handle the higher influent TKN values that were discovered during the special sampling
and in subsequent samples collected over the past several months (Figure 2-1).

Chapter 2_Final_ Design Summary.docx 2-1


Salisbury Wastewater Treatment Plant PER Chapter 2

Addition of rotary drum thickeners to thicken the waste activated sludge (WAS) prior to the first
tank of each aerobic digester / sludge holding tank train. This will allow Salisbury the flexibility to
either co-thicken the WAS and primary sludge in the primary clarifiers or thicken the WAS
separately in the rotary drum thickeners (Figure 2-2).
Addition of a surge bin after the dryer to cool down the material and stabilize the loading process
(Figure 2-2).

Table 2-1. Influent Basis of Design for Salisbury WWTP


Parameter Value
Flow (mgd): Annual Average 8.50
Maximum Month 10.30
Maximum Day 20.00
Peak Hour 25.40
cBOD5 (lb/day) Annual Average 20,600
Maximum Month 27,650
Maximum Day 43,650
Peak Hour 56,000
TSS (lb/day) Annual Average 19,100
Maximum Month 25,600
Maximum Day 40,400
Peak Hour 51,800
TKN (lb/day) Annual Average 3,800
Maximum Month 5,100
Maximum Day 8,060
Peak Hour 10,350
TP (lb/day) Annual Average 440
Maximum Month 580
Maximum Day 920
Peak Hour 1,180
Temp (C) Winter 10
Summer 26

2-2
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

2.3 Site and Yard Piping Plans


Figures 2-3 and 2-4 illustrate the proposed site plan and yard piping plan for the recommended liquid
and solids treatment processes, respectively. The color coded highlighting on the figures is as follows:
1) Red new process unit or equipment, 2) Yellow significant modifications to existing unit processes
or equipment and 3) Green either minor or no modifications to existing unit processes or equipment.
This is a high level overview of what is described in greater detail in chapters 3 through 21 of this PER.
The modifications between these site plans and those provided in the CAP are as follows:
Installation of the new alkalinity storage and feed system where an unused secondary
containment area is currently located.
Conversion of the Internal Recycle Valve Vault to a junction box to blend RAS and IMLR prior to the
Internal Recycle Junction Chamber.
Modifications to the biosolids storage building and the installation of an adjacent mixing / loading
/ unloading pad with controlled storm water runnoff.
Relocation of the new generator area to immediately adjacent to the new Blower Building to
provide backup power to MCC-11 that distributes power to most of the new equipment proposed
for this upgrade.
A fourth secondary clarifier west of secondary clarifier 3.
Shifting the supplemental Biological Tanks north into the adjacent property that the City plans to
acquire.
Relocation of the backflow preventer on the potable water line where it enters the WWTP site.
Shifting the UV building from west of the maintenance building to east of the maintenance
building.
Addition of a storm water treatment system on the eastern end of the site near the existing
chlorine contact basins.

2.4 Hydraulic Profiles


Figures 2-5, 2-6 and 2-7 illustrate the proposed hydraulic profiles for the recommended liquid treatment
process. Figure 2-5 represents the upstream portion of the Salisbury WWTP hydraulic profile from the
Headworks through the Supplemental Biological Tanks. Figures 2-6 and 2-7 represent the hydraulic
profiles for the Salisbury WWTP from downstream of the Supplement Biological Tanks through the outfall
in the Wicomico River. These two profiles represent two options that are still being considered: 1) Keep
the existing 30-inch outfall line and elevate the new UV structure or 2) install a new 36-inch outfall line
and reduce the height of the new UV structure. Brown and Caldwell used our proprietary Profile model to
develop these profiles. Profile model outputs are in Appendix C of this report.
It should be noted that there appears to have been a disconnect between the hydraulic calculations and
the hydraulic profile prepared by OBrien and Gere (OBG) as part of the BNR/ENR upgrades project. We
have determined that there is significantly more loss between the outfall and the effluent of the existing
filter structure than shown on the hydraulic profile in the as-built drawings. Details of how we propose
to overcome this obstacle are discussed in Chapters 9, 10 and 11.

2-5
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

2.5 Design Criteria for the Recommended Improvements


Table 1-2 provides a summary of all of the design criteria for the existing (re-used) and proposed
BNR/ENR improvements at the Salisbury WWTP required to achieve the nutrient removals and improved
performance required. New unit processes or equipment is highlighted by BOLD text, whereas existing
equipment or unit processes are normal font. Details on all of this information can be found in Chapters
3 through 21, which are arranged from the upstream to downstream end of the liquid treatment train
and then from the upstream to downstream end of the solids treatment train.

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
North Side Pump Station
Firm Pumping Capacity (mgd) 21.6
Number of Pumps, Large (Duty and Standby) 3 (2+1)
Motor Size (hp) 300
Type Yeomans, Vertical, Non-Clog Centrifugal
Design Point Flow Rate of Each Pump (gpm) 7,500
Design Point Total Dynamic Head (ft) 120
Design Point Minimum Flow Rate of Each Pump (gpm) 3,750
Number of Pumps, Jockey 1
Motor Size (hp) 200
Type Vertical, Non-Clog Centrifugal
Design Point Flow Rate of Each Pump (gpm) 3,750
Design Point Total Dynamic Head (ft) 120
Design Point Minimum Flow Rate of Each Pump (gpm) 1875
Number of Dimminutors (Duty and Standby) 4 (2+2)
Capacity (mgd) 23
Size (in) (LxWxH) 36x35x36
Odor Control Type Bioscrubber/ Biofilter
Air Changes Per Hour 12
Flow Rate (CFM) 1,000
Fan Size (hp) 5
Discharge Line Meter Size 24"
Type Magnetic
South Side Pump Station
Firm Pumping Capacity (mgd) 9.1
Number of Pumps, Large (Duty and Standby) 3 (2+1)
Motor Size (hp) 300
Type Yeomans, Vertical, Non-Clog Centrifugal
Design Point Flow Rate of Each Pump (gpm) 3,150

2-11
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Design Point Total Dynamic Head (ft) 175
Design Point Minimum Flow Rate of Each Pump (gpm) 1,575
Number of Pumps, Jockey 1
Motor Size (hp) 200
Type Vertical, Non-Clog Centrifugal
Design Point Flow Rate of Each Pump (gpm) 1,575
Design Point Total Dynamic Head (ft) 175
Design Point Minimum Flow Rate of Each Pump (gpm) 787
Number of Dimminutors (Duty and Standby) 2 (1+1)
Capacity (mgd) 23
Size (in) (LxWxH) 36x35x36
Odor Control Type Bioscrubber/ Biofilter
Air Changes Per Hour 12
Flow Rate (CFM) 1,000
Fan Size (hp) 5
Discharge Line Meter Size 24"
Type Magnetic
Bar Screens
Mechanical Bar Screens, Number and Type 2, Parkson AquaGuard
Channel Size, Width/ Depth (ft) 3/5
Capacity (mgd) 15.3
Bar Spacing (in.)
Motor Size (hp) 0.5
Manual Bar Screen, Number 1
Channel Size, Width/ Depth (ft) 5 / varies 2 2.5
Capacity (mgd) 15.3
Bar Spacing (in.) 2.25
Screenings Washers
Number and Type 2, Parkson SpiraKlean
Motor Size (hp) 3
Screenings Compactors
Number and Type 2, Parkson RotoPress
Motor Size (hp) 2
Grit Removal / Pump / Concentrator/ Washer/Classifier
Vortex Unit Number and Type 2, Grit King Vortexing Grit Unit
Capacity, Each Vortex Unit (mgd) 15.3
Hayward Gordon, XR4(11)-S Torus Recessed
Type of Girt Pump Impeller

2-12
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Number of Grit Pumps 3 (1 per Unit + Shelf Spare)
Flow Rate of Each Pump (gpm) 100 / 220 / 350
Design Point Total Dynamic Head 52 / 48 / 43
Grit Pump Motor Size (hp) 15
Number of Grit Concentrators 2
Number of Grit Washers/ Classifiers 2
Primary Clarifier 1
Diameter (ft) 110
Side Water Depth at Effluent Launder (ft) 11
Surface Area (sqft) 9500
Surface Overflow Rate at 8.5 mgd (gpd/ft2) 492
Surface Overflow Rate at 25.5 mgd (gpd/ft2) 1476
Drive Motor 0.5 hp, 460 V, 1800 rpm
Primary Clarifier 2
Diameter (ft) 100
Side Water Depth at Effluent Launder (ft) 11
Surface Area (sqft) 7850
Surface Overflow Rate at 8.5 mgd (gpd/ft2) 487
Surface Overflow Rate at 25.5 mgd (gpd/ft2) 1461
Drive Motor 0.5 hp, 460 V, 1800 rpm
Primary Scum Pump Station
Type Submersible Chopper
Number (Duty, Standby) 2 (1,1)
Capacity (gpm) 200
Total Dynamic Head (ft) 44
Motor Size (hp) 10
Primary Sludge Pump Station 1
Type Progressive Cavity
Number (Duty, Standby) 2 (1,1)
Capacity (gpm) 100 - 180
Design TSS (mg/L) 40000
Motor Size (hp) 10
Primary Sludge Pump Station 2
Type Seepex, Progressive Cavity
Number (Duty, Standby) 2 (2,0)
Capacity (gpm) 50 - 150
Design TSS (mg/L) 40000

2-13
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Motor Size (hp) 7.5
Internal Recycle Pump Station
Firm Pump Capacity (mgd) 80.6
Pump Type Fairbanks-Morse VTSH
Small Pump Number (Duty, Standby) 2 (2,0)
Discharge (in.) 16
Capacity Range (mgd) 2-9
Flow Rate at BEP (gpm/ mgd) 5,500 / 7.92
Total Dynamic Head (ft) at BEP 60
Large Pump Number (Duty, Standby) 4(3,1)
Discharge (in.) 24
Capacity Range (mgd) 7 - 18
Flow Rate at BEP (gpm/ mgd) 15,000 / 21.6
Total Dynamic Head (ft) at BEP 65
Anoxic Tanks
Number of Tanks 4
Diameter (ft) 70
Depth (ft) 18
Volume of Each Tank (MG) 0.5
Total Volume of Anoxic Tanks (MG) 2.0
Number of Mixers 4 (1 per tank)
Type of Mixer Invent
Mixer Horsepower (hp) 20
Supplemental Biological Tanks
Number of Trains 4
Aerobic Zone 1 Total Volume (MG) 1.47
Side Water Depth, (ft) 20
Alpha 0.45
SOTE (%) 40
DO at ADF Conditions (mg/L) 3.0
Average Air Flow (SCFM) 4,420
Maximum Air Flow (SCFM) 8,700
Number of Diffusers 3,600
Diffuser Density (%) 14.3
Aerobic Zone 2 Total Volume (MG) 1.47
Side Water Depth, (ft) 20

2-14
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Alpha 0.50
SOTE (%) 40
DO at ADF and Peak Conditions (mg/L) 3.0
Average Air Flow (SCFM) 2,430
Maximum Air Flow (SCFM) 5,960
Number of Diffusers 2,100
Diffuser Density (%) 8.3
Aerobic Zone 3 Total Volume (MG) 1.47
Side Water Depth, (ft) 20
Alpha 0.50
SOTE (%) 40
DO at ADF and Peak Conditions (mg/L) 2.0
Average Air Flow (SCFM) 1,470
Maximum Air Flow (SCFM) 3,620
Number of Diffusers 1,350
Diffuser Density (%) 5.4
Post Anoxic Zone Total Volume (MG) 2.25
Side Water Depth, (ft) 20
Number of Mixers 8 (2 per tank)
Type of Mixer Submersible
Aerobic Mixer Horsepower (hp) 10
Re-Aeration Zone Total Volume (MG) 0.5
Side Water Depth, (ft) 20
Alpha 0.50
SOTE (%) 40
DO at ADF and Peak Conditions (mg/L) 2.0
Average Air Flow (SCFM) 530
Maximum Air Flow (SCFM) 1,780
Number of Diffusers 600
Diffuser Density (%) 7.0
Blowers Number of Blowers (Duty + Standby) 4 (3+1)
Type of Blowers Direct Drive Turbo or Integrally Geared
Capacity of Each Blower (SCFM) 6,000
Horsepower 300
Secondary Clarifiers
Number of Clarifiers 4

2-15
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Diameter of Clarifiers 1, 3, and 4 (ft) 110
Diameter of Clarifier 2 100
Sidewater Depth of Clarifiers 1, 2, and 3 (ft) 9
Sidewater Depth of Clarifier 4 (ft) 16
Flocculator Center Well Diameter (ft) 33 to 36
Flocculator Center Well Depth Clarifiers (ft) 5
Sludge Collection Mechanism Tow-Bro Type
Type of Launders Outboard
Baffles Peripheral / Stamford
ADF Surface Overflow Rate (gpd/sq ft) 236
Peak Hour Surface Overflow Rate (gpd/sq ft) 700
ADF Solids Loading Rate (lbs / day / sq ft) 7
Peak Hour Solids Loading Rate (lbs / day / sq ft) 22
Weir Loading Rate (gpd / lf) 6,240
RAS Pumping
Type of Pump Submersible
Number of Pump Stations 4 (1 per SC)
Number of Pumps Per Pump Station (Duty+Standby) 2 (2+0)
Pump Design Capacity Each Pump (MGD) 1.1 to 1.4
Total Dynamic Head at Design Capacity (ft) 10
Motor Size (hp) 15
MLSS Wasting Pumps
Type of Pump Submersible
Number of Pumps (Duty+ Standby) 2 (1+1)
Pump Design Capacity (gpm) 250
Total Dynamic Head at Design Capacity (ft) 30
Motor Size (hp) 15
WAS Pumping
Type of Pump Positive Displacement - Seepex
Number of Pumps (Duty+ Standby) 2 (1+1)
Pump Design Capacity (gpm) 150 - 180
Total Dynamic Head at Design Capacity (ft) 30
Motor Size (hp) 10
Effluent Filter Pump Station
Type of Pump Vertical Turbine
Number of Pumps (Duty + Standby) 3(2+1)

2-16
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Pump Design Capacity (gpm/MGD) 7,100 / 10.2
Total Dynamic Head at Design Point (ft) 53
Normal Operating Condition 60% Speed, 6,000 gpm
Jockey Pump (replace existing Pump) Vertical Turbine
Number of Pumps (Duty + Shelf Space) 2 (1+1)
Pump Design Capacity (gpm / MGD) 3,000 / 5
Total Dynamic Head at Design Point (ft) 53
Effluent Filters Number of Existing Filter Cells 6
Number of New Filter Cells 3
Total Filter Area (sq ft) 2,700
Phase I Loading Rates (gpm/sq ft) (Avg/Peak) 2.2 / 6.6
Phase II Loading Rates (gpm/sq ft) (Avg/Peak) 2.6 / 7.9
Ultraviolet Disinfection
Low Pressure, High Output, pen Channel
Type of System Horizontal Lamps
Number of Channels 2
Peak Flow Capacity (mgd) (Now/Future) 25.5/30.6
UV Transmittance (%) 60
Max Suspended Solids (mg/L) 7
Min UV Dose at Peak Flow (Uws/cm2) 40000
Number of Banks/ Channel (Duty, Standby) 3 (2 +1)
Number of UV Lamps per Bank (Now/Future) 56/64
Total Number of Lamps (Now/Future) 336/384
Effluent Flow Meter
Type Magnetic
Size (in) 24 (Existing) + 24 (new)
Plant Outfall Line
Pipe Size (in) 30
Capacity (mgd) 30.6

Ferric Chloride Addition System


Design Dose under Average Influent Design Conditions (gpd) 475
Number of Metering Pumps (Duty and Standby) 4 ( 3+1)
Capacity of Each Metering Pump (gph) 220
Number of Bulk Storage Tanks 3
Total Volume of Storage Tanks (gal) 48,000
Alkalinity Addition System

2-17
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Chemical Used Magnesium Hydroxide
Design Dose under Average Influent Conditions (mg/L) Maintain 50 mg/L Alkalinity
Number of Metering Pumps (Duty and Standby) 1 (1+shelf spare)
Capacity of Each Metering Pump (gph) 50
Number of Recirculation Pumps (Duty and Standby) 1 (1+0)
Capacity of Each Metering Pump (gpm) 125
Number of Bulk Storage Tanks 1
Volume of Storage Tank (gal) 7,500
Polymer Addition System
Chemical Used Dry Polymer
Delivery Concentration (wt %) 0.25 to 0.5
Number of Metering Pumps (Duty and Standby) 4 (2+2)
Capacity of Each Metering Pump (gpm) 10
Number of Make-Up Units / Tanks 2
Make-Up Unit Design Capacity (lb/day) 600
Supplemental Carbon Addition
System
Chemical Used for Denitrification MicroC, Sodim Acetate or Other
Chemical Demand (gpd) AADF/MMF Requirement (Micro C) 750 / 950
Chemical Demand (gpd) 3* AADF 2,250
Type of Metering Pumps (for Supplemental Carbon) Magnetic Drive Seal-less Gear Pump
Number of Metering Pumps (for Supplemental Carbon) (Duty
and Standby) 2 (2,0)
Capacity Range of Each Metering Pump (gpd) 300 - 2,200
Number of Bulk Storage Tanks 3
Current System Storage Volume (gal) 14.025
Number of Storage Days at AADF 5 - 8.5 mgd 19
Plant Drain Pump Station
Wet Well Type Circular Hopper Style
Diameter / Depth (ft) 12 / 15
Pump Type Submersible
Number of Pumps (Duty + Standby) 3 (2+1)
Peak Flow (mgd) 2.1
Capacity of Each Pump (mgd) 1.05
Total Dynamic Head (ft) at Peak Flow 37
Motor Size (hp) 15
Aerobic Digestion
Tank 1 - Digester Tank

2-18
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Inside Diameter (ft) 55
Side Wall Depth (ft) 22
Side Water Depth (ft) 20.5
Center Depth (ft) 29
Center Well Depth (ft) 27.5
Approximate Effective Volume (gal) 400,000
Tanks 2 and 3 - Digester Tanks
Inside Diameter (ft) 60
Side Wall Depth (ft) 18
Side Water Depth (ft) 16.5
Center Depth (ft) 25
Center Well Depth (ft) 23.5
Approximate Effective Volume (gal) 400,000
Tank 4
Approximate Effective Volume (gal) 250,000
Process SRT (days) (5 - 8.5 mgd) 16 - 10
Volatile Solids Destruction (%) 10
Rotary Drum Thickers
Number of rotary Drum Thickers 2 (1 per train)
Type of RDT Single Drum
Maximum flow (gpm) 275
Wash Water Flow (gpm) 15-20
RDT Motor size (hp) 3
Aeration Blowers
Blower Type United Blower - Model RAM 616
Number of Blowers 4
Blower Capacity (scfm) 1,650
Blower Motor Size (hp) 125
Total Blower Capacity (scfm) 6,600
Oxygen Delivered per Blower (lb/day) 6,226
Total Oxygen Delivered (lb/day) 24,905
Assumed Standard Oxygen Transfer Efficiency (%) 15
Air Delivered per Volume Sludge 31 - 34 scfm /1000 cf
Transfer and BFP Feed Pumps
Manufacturer / Model Seepex, 130
Number of Pumps (Duty + Standby) 5
Conveying Capacity (gpm) (Min, Nominal, Max) 150, 337, 400

2-19
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Pump Speed (rpm) 78, 176, 209
Motor Size (hp) 30
Upstream Inline Grinder Line Size (in) 6
Dewatering
Belt Filter Press Manufacturer Ashbrook
Number of Units 2
High-Solids, Klampress, KP, 2.0 M, 3 Belt,
Model / Size Standard Deck
Connected Load per Unit (Excl. Wash Water Pump) (hp) 11.5
Polymer Feed System Manufacturer Siemens/ Stranco
Number of Units 2
PolyBlend Model #M2400-D10AB
Model / Size (SP60102330)
Polymer Capacity (gph) 0.5 - 10
Polymer Delivery Diaphragm-type Metering Pump
Working Pressure (psi) 100
Motor Size (hp) 1
Primary and Post Dilution Water Capacity (gph) 1,200
Cake Pumping
Pump Manufacturer Seepex
Number of Units/ Model / Size 2/ BTHE/ 17
Maximum Pressure (bar/ psi) 24/ 348
Maximum Solids Content (%) 25
Density (kg/dm3) 1.05
Conveying Capacity (gpm) (Min, Nominal, Max) 1, 4.7, 10
Pump Speed (rpm) 61, 78, 102
Frequency (Hz) 47, 60, 79
Differential Pressure (psig) 325
Operating Torque (ft-lb) 310
Starting Torque (ft-lb) 413
Required Drive Power (hp) 6.23
Motor Size (hp) 15
Dryer
Processing Capacity (WT biosolids/ day) 48 / 80
Sludge Solids Content (%) 20 - 35
Thermal Fluid Heat Exchanger & Natural Gas Burner
(MMBTU/h) 9 / 12.5
Surge Bin Size (cuft) 86 / 170
Combustion Air Blower Size (hp) 5 / 7.5

2-20
Chapter 2_Final_ Design Summary.docx
Salisbury Wastewater Treatment Plant PER Chapter 2

Table 2-2. Basis of Process Design for Recommended Improvements


Unit Process Design Parameter Design Value
Primary Recirculation Pump (hp) 25 / 30
Expansion Tank (gal) 660
Steam Condensing System, Input - Output (ACFM @deg F) 300 @ 180 - 123 @ 93
Condenser Fan (hp) 50 / 20
Biosolids Storage
Biosolids Storage Building Size LxWxH (ft) 120x8x6
Available Storage for 20% Dewatered Solids Using Bins/ Bulk
Method (Days) 15 / 18
Available Storage for 90% Dried Solids Using Bins/ Bulk
Method (Days) 68 / 81
New North Wall Height (ft) 8
Mixing Pad Size LxW (ft) 60x60
New Eastern Wall Height (ft) 8
Drainage Pipe Size (in) 12
Storm Water Improvements
Criteria of Volume to be Treated of Rainfall First Flush (1st 1")
Drainage Area 1 - Water Volume to be Treated (ft3) 19,448
Drainage Area 2 - Water Volume to be Treated (ft3) 1,857
Low-Impact Development Stormwater Control
DA-1 Preferred Treatment Method Measures
DA-1 Pump Type, Number and Size (hp) Subersible, 2
DA-1 Pump Duty Capacity (gpm)/ Head (ft) 50 / 12
DA-1 Basin Size 1 LxWxH (ft) 50x15x12
DA-1 Basin Size 2 LxWxH (ft) 100x30x8
DA-2 Preferred Treatment Method Stormwater Control Measures
DA-0 Preferred Treatment Method Re-grading
Electrical System
Plant Power Distribution System Type 480VAC, 3 Phase, 60Hz, 4 Wire
Single Utility Feed Size 25 KV
Generator Size 2500KW, 480VAC

2-21