You are on page 1of 11

PROJECT AL MUFTA VILLA

DISTRIBUTION BOARD REFERENCE 16WAY DISTRIBUTION BOARD -DB-GF


LOCATION GROUND FLOOR
FED FROM MSB
INCOMING CABLE 4C-25mm2 PVC/PVC +1C-16mm2 PVC/ECC
INCOMING ISOLATING SWITCH 80A TP ISOLATOR

Ways LOAD IN WATTS MCB DESCRIPTION


R Y B
1000 10A D1 LTS IN SALON -01 @GF
1 800 10A D5 LTS IN SALON -01 @ GF
1000 10A DI AND W2 LTS @ SALON -02
550 5A D1& COVE LTS @ OFFICE
2 800 10A D1 LTS @ SITTING & LOBBY
650 10A LTS IN SALON -02 @ GF
200 10A EF IN KITCHEN
3 600 32A* 3 TWIN SOCKETS IN KITCHEN
800 10A D5 AND COVE LTS @ SITTING & LOBBY
600 10A D1 LTS IN DINING @ GF
4 900 10A D4 LTS IN KITCHEN
600 10A D5 LTS IN DINING @ GF
300 10A* D3 LTS IN TOILET, WASH RM & EF-01
5 10A SPARE
900 30A* 4 TWIN & 1 SINGLE SOCKET @ OFFICE
400 30A* 2TWIN SOCKET @ DINING
6 10A SPARE
10A SPARE
1200 10A* W2 EXTERNAL LIGHTS
7 4000 45A* COOKER UNIT
1000 30A* 4TWIN & 2 SINGLE SOCKET @ SALON -02
500 20A SWITCHED SPUR UNIT FOR FCU-01 @GF-OFFICE
8 500 20A SWITCHED SPUR UNIT FOR FCU-02 @ DINING
750 20A SWITCHED SPUR UNIT FOR FCU-03 @ GF-KITCHEN
750 20A SWITCHED SPUR UNIT FOR FCU-04 @ GF-SITTING AREA
9 1000 30A* 4 TWIN & 2 SINGLE SOCKET @ SALON -01
500 20A SWITCHED SPUR UNIT FOR FCU-05 @ GF-SALON -01
2500 20A* EWH-01 @ TOILET/WASH
10 750 20A SWITCHED SPUR UNIT FOR FCU-06 @ GF-SALON -02
2500 20A* EWH-02 @ KITCHEN
500 10A CHANDELIER @ DINING
11 500 10A CHANDELIER @ DINING
10A SPARE
500 10A CHANDELIER @ SITTING AREA
12 20A SPARE
12
1000 10A W1 LTS IN STAIRS
500 10A CHANDELIER @ SALON -01
13 500 10A CHANDELIER @ SALON -02
20A SPARE
20A SPARE
14 20A SPARE
10A SPARE
30A* SPARE
15 30A* SPARE
SPACE
SPACE
16 SPACE
SPACE
PHASE LOAD9500 10350 9700 * DENOTES MCB / ELCB COMBINED UNIT 30mA SENSITIVITY
TOTAL CONNECTED LOAD 29.55 KW

TOTAL CONNECTED
AC WH COOKER GENERAL OTHERS LOAD (kW)

3.75 5 4 16.8 29.55


ILLA
TRIBUTION BOARD -DB-GF
LOOR

PVC/PVC +1C-16mm2 PVC/ECC


LATOR

DESCRIPTION PVC WIRE(mm2)

ALON -01 @GF 3X2.5


ALON -01 @ GF 3X2.5
LTS @ SALON -02 3X2.5
LTS @ OFFICE 3X2.5
ITTING & LOBBY 3X2.5
ON -02 @ GF 3X2.5
HEN 3x2.5
CKETS IN KITCHEN 4X4 + 2X2.5
VE LTS @ SITTING & LOBBY 3X2.5
INING @ GF 3X2.5
ITCHEN 3X2.5
INING @ GF 3X2.5
OILET, WASH RM & EF-01 3X2.5

SINGLE SOCKET @ OFFICE 4X4 + 2X2.5


CKET @ DINING 4X4 + 2X2.5

NAL LIGHTS 3X2.5


3X6
SINGLE SOCKET @ SALON -02 4X4 + 2X2.5
SPUR UNIT FOR FCU-01 @GF-OFFICE 3X4
SPUR UNIT FOR FCU-02 @ DINING 3X4
SPUR UNIT FOR FCU-03 @ GF-KITCHEN 3X4
PUR UNIT FOR FCU-04 @ GF-SITTING AREA 3X4
SINGLE SOCKET @ SALON -01 4X4 + 2X2.5
SPUR UNIT FOR FCU-05 @ GF-SALON -01 3X4
TOILET/WASH 3X6
SPUR UNIT FOR FCU-06 @ GF-SALON -02 3X4
KITCHEN 3X6
R @ DINING 3X4
R @ DINING 3X4

R @ SITTING AREA 3X4


STAIRS 3X2.5
R @ SALON -01 3X4
R @ SALON -02 3X4

COMBINED UNIT 30mA SENSITIVITY

MAXIMUM DEMAND LOAD (kW)

20.4
PROJECT AL MUFTA VILLA
DISTRIBUTION BOARD REFERENCE 18WAY DISTRIBUTION BOARD -DB-FF
LOCATION CORRIDOR
FED FROM MSB-V2
INCOMING CABLE 4C-35mm2 PVC/PVC +1C-16mm2 PVC/ECC
INCOMING ISOLATING SWITCH 80A TP ISOLATOR

Ways LOAD IN WATTS MCB DESCRIPTION


R Y B
700 10A D5 LTS small Masterbedroom (right Top) @ FF
I 400 10A D1 LTS Masterbedroom (right top) @ FF
600 10A* LTS @ TOILET, DRESSING RM, HALLWAY & EF (RIGHT TOP) @FF
200 10A LTS Double height @ FF
2 400 10A LTS Master.BR -02 (RB)@ FF
500 10A* LTS in TOILET, DRESSING RM, HALLWAY & EF (RIGHT Bottom) @F
16A
3 600 10A LTS @ LOBBY & LIVING AREA
500 10A LTS @ HALLWAYS in FF
900 10A* LTS DRESSING,covelights & TOILET + EF+Small Master Bedroom(M
4 1000 10A D1 LTS in Dressing Room-2 and Toilet & EF @ FF
10A
300 10A LTS IN CONNECTION CORRIDOR @ FF
5 500 16A CHANDLIER @ MASTER BEDROOM -PENT HOUSE
400 10A D1 LTS @ MASTER BEDROOM -PENT HOUSE
10A
6 400 10A LTS @ ELEVATOR WALL
700 32A 13A SOCKETS FOR NEW MASTER BEDROOM (RB) @ FF
800 32A* 13A SOCKETS FOR NEW MASTER BEDROOM @ FF-Master BR-0
7 700 32A* 3 TWIN & 1 SINGLE SOCKET MASTER BEDROOM (RT) @ FF
500 20A SWITCHED SPUR UNIT FOR FCU-13 @ LIVING AREA
500 32A* 2 TWIN & 1 SINGLE SOCKET DRESSING ROOM (LT)@ FF
8 700 32A* 13A SOCKETS @ PH-MasterBedroom
750 20A SWITCHED SPUR UNIT FOR FCU-08 IN BR (LT)@ FF
500 20A SWITCHED SPUR UNIT FOR FCU-07 M.Bedroom (M)@ FF-B
9 800 16A* LIGHTS @ LOBBY,DRESSING & BATH/TOILET-PH
750 20A SWITCHED SPUR UNIT FOR FCU-9 @ FF-BR-03
750 20A SWITCHED SPUR UNIT FOR FCU- 10 Master bedroom(LB)@
10 500 20A SWITCHED SPUR UNIT FOR FCU-11 D.R 1 @ FF
1250 20A SWITCHED SPUR UNIT FOR FCU-12 @ FF-SITTINGROOM
2500 20A* EWH-05 @ TOILET/BATH (M)
11 2500 20A* EWH-04 @ TOILET/BATH (RT) -FF
2500 20A* EWH-06@ TOILET/BATH (RB) @ FF
500 10A CHANDELIER in master bedroom (right top) (@ FF
12 10A
12
2500 20A* EWH-03@ TOILET/BATH (RT)
2500 20A* EWH-07@ BATH PENT HOUSE
13 500 10A CHANDELIER AT DOUBLE HEIGHT FRONT@ FF
500 10A CHANDELIER Master bedroom (BR) @ FF
32A*
14 500 10A CHANDELIER IN LIVING AREA @ FF
10A
750 20A SWITCHED SPUR UNIT FOR FCU-13 @PENT HOUSE
15 600 10A LIGHTS @ ROOF
900 10A LIGHTS IN NEW MASTER BEDROOM@FF
1000 10A CHANDLIER LIGHTS IN NEW MASTER BEDROOM@FF
16 1000 32A* 4 TWIN & 1 SINGLE SOCKET LIVING ROOM @ FF
SPACE
500 10A D1 LIGHTS IN NEW DRESSINGROOM @ FF
17 1500 20A SWITCHED SPUR UNIT FOR FCU-14@ PH-STAIRS
SPACE
SPACE
18 700 32* 13A SOCKETS MASTER BEDROOM (M) @ PH
SPACE
TOTAL 12400 13300 12350 * DENOTES MCB / ELCB COMBINED UNIT 30mA SENSITIVITY
CONNECTED LOAD 38.05 KW

AC WH COOKER GENERAL OTHERS

7.25 12.5 18.3


ARD -DB-FF

6mm2 PVC/ECC

DESCRIPTION PVC WIRE(MM2)

right Top) @ FF 3X2.5


op) @ FF 3X2.5
, HALLWAY & EF (RIGHT TOP) @FF 3X2.5
3X2.5
3X2.5
, HALLWAY & EF (RIGHT Bottom) @FF 3X2.5
3X2.5
A 3X2.5
3X2.5
OILET + EF+Small Master Bedroom(M) @ FF 3X2.5
d Toilet & EF @ FF 3X2.5
3X2.5
OR @ FF 3X2.5
DROOM -PENT HOUSE 3X4
M -PENT HOUSE 3X2.5
3X2.5
3X2.5
STER BEDROOM (RB) @ FF 4X4 + 2X2.5
STER BEDROOM @ FF-Master BR-01 4X4 + 2X2.5
MASTER BEDROOM (RT) @ FF 4X4 + 2X2.5
R FCU-13 @ LIVING AREA 3X4
DRESSING ROOM (LT)@ FF 4X4 + 2X2.5
edroom 4X4 + 2X2.5
R FCU-08 IN BR (LT)@ FF 3X4
R FCU-07 M.Bedroom (M)@ FF-BR1 3X4
& BATH/TOILET-PH 3X2.5
R FCU-9 @ FF-BR-03 3X4
R FCU- 10 Master bedroom(LB)@FF 3X4
R FCU-11 D.R 1 @ FF 3X4
R FCU-12 @ FF-SITTINGROOM 3X4
M) 3X6
RT) -FF 3X6
@ FF 3X6
m (right top) (@ FF 3X4
3X2.5
) 3X6
SE 3X6
IGHT FRONT@ FF 3X4
(BR) @ FF 3X4

@ FF 3X4
3X2.5
R FCU-13 @PENT HOUSE 3X4
3X2.5
ROOM@FF 3X2.5
MASTER BEDROOM@FF 3X4
LIVING ROOM @ FF 4X4 + 2X2.5

GROOM @ FF 3X2.5
R FCU-14@ PH-STAIRS 3X4

ROOM (M) @ PH 4X4 + 2X2.5

30mA SENSITIVITY

MAXIMUM DEMAND
TOTAL CONNECTED LOAD (kW) LOAD (kW)

38.05 25.06
LOAD SUMMARY FOR MSB-V2
(EXISTING KM METER 49095)
ITEM GENERAL
AC WH COOKER OTHERS
1 DB-GF 3.75 5.00 4.00 16.80 0.00 0.00
2 DB-FF 7.25 12.50 0.00 18.30 0.00 0.00
3 LIFT 0.00 0.00 0.00 0.00 0.00 15.00
4 ACCU-01 30.00 0.00 0.00 0.00 0.00 0.00
5 BOOSTER PUMP 0.00 0.00 0.00 0.00 0.00 2.50
6 TRANSFER PUMP 0.00 0.00 0.00 0.00 0.00 2.50
7 ACCU (FUTURE) 17.00 0.00 0.00 0.00 0.00 0.00
ACCU-02 12.00 0.00 0.00 0.00 0.00 0.00
TOTAL 70.00 17.50 4.00 35.10 20.00
TOTAL CONNECTED LOAD IN KW
MAXIMUM DEMAND LOAD IN KW

TOTAL ELECTRICAL LOAD SUMMARY


ITEM

AC WH COOKER GENERAL OTHERS

EXISTING MSB-V 1 (EXISTING


KM METER 49094) NO LOAD 17.00 22.00 8.00 80.00 38.00
MODIFICATION

MODIFIED MSB-V 2 (EXISTING 70.00 17.50 4.00 35.10 20.00


KM METER 49095)

TOTAL 87.00 39.50 12.00 115.10 58.00


TOTAL CONNECTED LOAD IN KW
MAXIMUM DEMAND LOAD IN KW
LOAD SUMMARY FOR MSB-V1
(EXISTING KM METER 49094)
ITEM GENERAL
TOTAL AC WH COOKER LIGHTS
29.55 DB-GF1 6.00 4.00 4.00 20.00
38.05 DB-GF2 5.00 6.00 0.00 18.00
15.00 DB-FF1 4.00 6.00 4.00 6.00
30.00 BOOSTER PUMP 0.00 0.00 0.00 0.00
2.50 TRANSFER PUMP 0.00 0.00 0.00 0.00
2.50 DB-K 2.00 6.00 0.00 4.00
17.00 TOTAL 17.00 22.00 8.00 80.00
12.00
146.60 TOTAL CONNECTED LOAD I
146.60 MAXIMUM DEMAND LOAD I
119.37

TOTAL MAXIMUM
CONNECTED DEMAND
LOAD (kW) LOAD (kW)

165.00 115.8

146.60 119.37

311.60 235.17
311.60
235.17
TER 49094)
GENERAL
POWER OTHERS TOTAL
14.00 5.00 53.00
10.00 6.00 45.00
3.00 6.00 29.00
0.00 3.00 3.00
0.00 6.00 6.00
5.00 12.00 29.00
80.00 38.00 165.00

TOTAL CONNECTED LOAD IN KW 165.00


AXIMUM DEMAND LOAD IN KW 115.8