You are on page 1of 4

IGBT HALF BRIDGE

INPUTS half BRIDGE INPUTS HEATING


P 100 KW P 50 KW
V 415 V V 415 V
VDC 560.25 V VDC 560.25 V
VIN 504.225 V VIN 504.225 V
FRE 3000 HZ FRE 10000 HZ
MULTI 1 MULTI 1
Q 15 Q 11
PF 0.0666667 PF 0.090909

THEIR CAP V 1204.3591 V CAP V 300 V


OUTPUTS OUTPUTS
WANTED COIL V 100

IGBT I 1245 A COIL I 311 A


CAP MFD(PRIM) 55 uF CAP MFD 17 uF
CALCULATED COIL L(PRIM) 51 uH COIL IND 15 uH
ENTER COIL L 0.0340 uH
XMER RATIO 38.853527

coil i (2*3.14*P*1000)/V IN
CALCULATION OF INDUCTANCE
INPUTS
coil length 300 mm 0.3 mt
coil tube width 0.75 inch 19.05 mm
coil id 82 mm 0.10105 mt
coil turns 27 27
0.00000123 ohms-mtr

OUTPUTS
ind 20.3466 uH

inductance=2**D^2*N^2/3*length
IGBT FULL WAVE BRIDGE WITH MATCHING XMER

P 50 KW
I LINE 75 A
VDC 560 V
I DC 90 A
VMF 252 V #VDC*0.9
IMF(IGBT I) 206.7 A #P*1000/(VMF*0.96)
IGBT I PK 292.3 A
ENTER Q 11
ENTER N 1

V CAP 2772 V #Q*VMF/N


I COIL 207 A #N*IMF
INVETER PF 0.0909 #1/Q
ENTER FREQ 10000 HZ
KVAR 550 #Q*P
C 1.14 uF #KVAR=2*3.14*F*C*V^2
L 222.47 uH #F=1/(2*3.14*SQRT(LC)
prim 1.1397683524
IGBT HALF WAVE BRIDGE WITHOUT MATCHING XMER

P 100 KW
I LINE 150 A
VDC 560 V
I DC 180 A
ENTER IMF(IGBT I) 675.0 A
IGBT I PK 954.6 A
ENTER CAP V 1200 V

INVETER PF 0.1235 #P/I*V


ENTER FREQ 10000 HZ
Q 8 #1/PF
KVAR 810 #Q*P
C 8.96 uF #KVAR=2*3.14*F*C*V^2
L 28.31 uH #F=1/(2*3.14*SQRT(LC)