Directions For Electronic Mix Design TR 4221-A / Batcher Mixer

CS 4220 Process

1. Download Mix Design / Batcher Mixer Excel spreadsheet files from PENNDOTs web
site www.dot.state.pa.us / General Information / Publications / Forms, Publications
and Maps or PACAs web site www.pacaweb.com

2. Open the Mix Design File and save it as your master file.

3. Enter information on the mix design form. The cells with a red corner have prompts
built in to the program.

4. Use Save As and name the file with the mix design number. 04-3A012 First 2 digits
are the year. Dash. Next 2 digits are the class: 1C to 3A. The last 3 spaces are the
numbers or letters used to designate the mix.

5. E-mail the mix design files to the appropriate District Materials Unit
RA-PDDistrict7-0mat@state.pa.us with the request to use the mix designs.

6. The District Materials Unit will evaluate the mix design information and reply to the
e-mail stating if the mixes can be used.

7. The producer is to keep (save, print, etc) the mix design information and the District
Materials Engineers e-mail reply.

I. Open the Batcher Mixer File and save it as your master file.

II. Use as appropriate during production. Paper copies of the Batcher Mixer slip
will need to be sent to the projects because of limited email capability.
TR-4221A (02-09) Material Class:
CONCRETE MIX DESIGN FORM Date:
JMF No.: District:
ECMS No.:
SR/WO: Sec/Segmt: Contractor:
Concrete Producer: Location:
Supplier Code: Supplier Internal Code: FA No:

Material Code Product Name


Material ASTM Type Producer Name - Location Supplier Code: Sp. Gr. Abs. Asr. Lab No.
Cement 1 3.15
Pozzolan 1 F 2.40
Pozzolan 2 2.20
Coarse Agg. #1 A57 2.78
Coarse Agg. #2 A8 2.78
Fine Agg. A 2.61
Water WTRMIX Oz/yd (As Req.) Mfg Dose/cwt
Admixture AEA Oz/cwt 6 36 Min Max
Admixture Oz/cwt 3 18 3 15
Admixture Oz/cwt 3 18 3 12
Admixture Oz/cwt 3 18 3 8
*When using a WR admixture,
% Sol
Admixture > 127 ounces it must be used at the
wt/gal manufacturer's minimum
dosage rate to use the
% Sol maximum 6 1/2" slump spec
Admixture > 127 ounces per 704.1(d)4.a. When using
wt/gal a HRWR admixture, it must be
used at the manufacturer's
Total admix water per cubic yard = 0.0 Lbs/yd minimum dosage rate to use
*When RE admixture is used in concrete 80 F and over or in hot
weather, the Manufacturer's Minimum recommended dosage Total admix solids per cubic yard = 0.0 Lbs/yd the maximum 8" slump spec
per 704.1(d)4.a. Any
rate for RE admixture must be used to get 90 minutes of mixing W/C Ratio Taken From Worksheet Dated: additional admixtures utilized
time. to enhance the concrete
7/28 Day Strength Ratio: performance may be below
the manufacturer's minimum
recommended doseage rate.
Strength Data Based On Max W/C: 0.43
Step-Down Interval: 0.01

Compressive Strength, F'c: 0 hours 0 psi(avg) 0 days 0 psi(avg)


Compressive Strength, F'c: 0 days 0 psi(avg) 0 days 0 psi(avg)

Mix Number 1 2 3 4 5
W/C Ratio by (wt) 0.430 0.420 0.410 0.400 0.390
Cement (lbs) 400 400 400 400 400
Pozzolan 1 (lbs) 100 100 100 100 100
Pozzolan 2 (lbs) 100 100 100 100 100
Total Cementitious 600 600 600 600 600
Coarse aggregate 1 (lbs) 1388 1388 1388 1388 1388
Coarse aggregate 2 (lbs) 347 347 347 347 347
Total Coarse aggregate (lbs) 1735 1735 1735 1735 1735
Fine aggregate (lbs) 1273 1288 1304 1320 1335
Total water (lbs) 258 252 246 240 234
Admixture water (lbs)
Mix water (lbs) 258 252 246 240 234
Admixture solids/yd (lbs) 0 0 0 0 0
Total (lbs) 3865 3875 3885 3894 3904
Unit weight (lbs/cu. ft.) 143.16 143.52 143.88 144.24 144.59
Coarse aggregate vol. (cu.ft.) 10.00 10.00 10.00 10.00 10.00
Total water (Gal) 31.0 30.3 29.5 28.8 28.1
Mix water (Gal) 31.0 30.3 29.5 28.8 28.1

Designed by: Date:

Approved & Submitted by: Date:

Reviewed by Contractor: Date:

Reviewed by Materials Engr/Mgr: Date:

Page 1 of 4
TR 4221A (02-09)
Concrete Mix Design Form Matl. Class:
Date:
District:
ECMS:
MIX DESIGN WORKSHEET
Concrete Producer: Project or Plant:

Square Screen Analysis, % Passing

Screen sizes 1 1/2" 1" 3/4" 1/2" 3/8" #4 #8 #16 #30 #50 #100

A57

A8

FM 6.00

Maximum Density: lbs/ft, ssd % Hardened Air Test Results: % solids: (Bulletin 5 method)
CA Volume: (Bulletin 5 method)
Dry Rodded Unit wt: lbs/ft, ssd
Volume of Dry Rodded coarse aggregate(s) per unit Volume of concrete: (ACI 211 method)

Wt/Volume calculations

W/C Ratio: 0.43 MIX # 1 (show adjustments on additional page(s))

Cement 1 (type) = 2.04 feet x S.G. x 62.4 = 400 lbs

Pozzolan 1 F (type) = 0.67 feet x S.G. x 62.4 = 100 lbs

Pozzolan 2 0 (type) = 0.73 feet x S.G. x 62.4 = 100 lbs

Check CF or Lbs for C. Agg. Entry: 1 CF 1 LBS 8 CF


C. Agg. #1 A57 (grading) = 8.00 feet x S.G. x 62.4 = 1388 lbs

1 1 2 CF
C. Agg. #2 A8 (grading) = 2.00 feet x S.G. x 62.4 = 347 lbs

Total C. Agg = 10.00 feet 1735 lbs

Water 31.0 (Gals.) = 4.13 feet x S.G. x 62.4 = 258 lbs

% Air 6.0 % / 100 x 27.0 = 1.62 feet


Admix (Solids, if = 0 lbs
Nec.)
SUBTOTAL = 19.19 feet

F. Agg. 27.0 - (subtotal) = 7.81 feet x S.G. x 62.4 = 1273 lbs

TOTALS = 27.00 feet 3865 lbs

Temperature: Concrete: F Air: F Unit Wt. 143.16 lbs/ft Calculated


Initial Testing: Slump: in. Air Content % Unit Wt. 0.00 lbs/ft Actual
At Pt of Placement: Slump: in. Air Content % Mortar Content 19.00 ft

Strength DAYS/HRS 1 2 AVE DAYS 1 2 AVE


F'c, (compressive), psi 0 0
F'c, (compressive), psi 0 0
TR 4221A (02-09) Matl. Class:
CONCRETE MIX DESIGN FORM Date:
District:
ECMS No.:

Wt / Volume calculations
W/C Ratio: 0.42 MIX # 2 (show adjustments on additional page(s))

Cement 1 (type) = 2.04 feet x S.G. x 62.4 = 400 lbs

Pozzolan 1 F (type) = 0.67 feet x S.G. x 62.4 = 100 lbs

Pozzolan 2 0 (type) = 0.73 feet x S.G. x 62.4 = 100 lbs

C. Agg. 1 A57 (grading) = 8.00 feet x S.G. x 62.4 = 1388 lbs

C. Agg. 2 A8 (grading) = 2.00 feet x S.G. x 62.4 = 347 lbs

Water 30.3 (Gals.) = 4.04 feet x S.G. x 62.4 = 252 lbs

Admix (Solids, if = 0 lbs


% Air 6 % / 100 x 27.0 = 1.62 feet Nec.)

SUBTOTAL = 19.09 feet

F. Agg. 27.0 - (subtotal) = 7.91 feet x S.G. x 62.4 = 1288 lbs

TOTALS = 27.00 feet 3875 lbs

Wt / Volume calculations
W/C Ratio: 0.41 MIX # 3 (show adjustments on additional page(s))

Cement 1 (type) = 2.04 feet x S.G. x 62.4 = 400 lbs

Pozzolan 1 F (type) = 0.67 feet x S.G. x 62.4 = 100 lbs

Pozzolan 2 0 (type) = 0.73 feet x S.G. x 62.4 = 100 lbs

C. Agg. 1 A57 (grading) = 8.00 feet x S.G. x 62.4 = 1388 lbs

C. Agg. 2 A8 (grading) = 2.00 feet x S.G. x 62.4 = 347 lbs

Water 29.5 (Gals.) = 3.94 feet x S.G. x 62.4 = 246 lbs

Admix (Solids, if = 0 lbs


% Air 6 % / 100 x 27.0 = 1.62 feet Nec.)

SUBTOTAL = 18.99 feet

F. Agg. 27.0 - (subtotal) = 8.01 feet x S.G. x 62.4 = 1304 lbs

TOTALS = 27.00 feet 3885 lbs


TR 4221A (02-09) Matl. Class:
CONCRETE MIX DESIGN FORM Date:
District:
ECMS No.:

Wt/Volume calculations
W/C Ratio: 0.40 MIX # 4 (show adjustments on additional page(s))

Cement 1 (type) = 2.04 feet x S.G. x 62.4 = 400 lbs

Pozzolan 1 F (type) = 0.67 feet x S.G. x 62.4 = 100 lbs

Pozzolan 2 0 (type) = 0.73 feet x S.G. x 62.4 = 100 lbs

C. Agg. 1 A57 (grading) = 8.00 feet x S.G. x 62.4 = 1388 lbs

C. Agg. 2 A8 (grading) = 2.00 feet x S.G. x 62.4 = 347 lbs

Water 28.8 (Gals.) = 3.85 feet x S.G. x 62.4 = 240 lbs

Admix (Solids, if = 0 lbs


% Air 6 % / 100 x 27.0 = 1.62 feet Nec.)

SUBTOTAL = 18.90 feet

F. Agg. 27.0 - (subtotal) = 8.10 feet x S.G. x 62.4 = 1320 lbs

TOTALS = 27.00 feet 3894 lbs

Wt/Volume calculations
W/C Ratio: 0.39 MIX # 5 (show adjustments on additional page(s))

Cement 1 (type) = 2.04 feet x S.G. x 62.4 = 400 lbs

Pozzolan 1 F (type) = 0.67 feet x S.G. x 62.4 = 100 lbs

Pozzolan 2 0 (type) = 0.73 feet x S.G. x 62.4 = 100 lbs

C. Agg. A57 (grading) = 8.00 feet x S.G. x 62.4 = 1388 lbs

C. Agg. A8 (grading) = 2.00 feet x S.G. x 62.4 = 347 lbs

Water 28.1 (Gals.) = 3.75 feet x S.G. x 62.4 = 234 lbs

Admix (Solids, if = 0 lbs


% Air 6 % / 100 x 27.0 = 1.62 feet Nec.)

SUBTOTAL = 18.80 feet

F. Agg. 27.0 - (subtotal) = 8.20 feet x S.G. x 62.4 = 1335 lbs

TOTALS = 27.00 feet 3904 lbs