Professional Documents
Culture Documents
Reference:
Pedoman Perencanaan Ketahanan Gempa Untuk Rumah dan Gedung
SKBI 1.3.53.1987 UDC:699.841 (SNI 1726-1989-F)
Location = Ende
Seismic Zone = 3
A. BOILER STRUCTURE
Structure Height, H (m) = 25
V =CIKW
B. STACK
Structure Height, H (m) = 39.624
T =0 . 085 H 3/4
Basic Seismic Coefficient, C = 0.0353
V =CIKW
1 2 3 4 5 6
0.00 0.1300 0.0900 0.0700 0.0500 0.0300 0.0000
0.50 0.1300 0.0900 0.0700 0.0500 0.0300 0.0000
1.00 0.1300 0.0900 0.0700 0.0500 0.0300 0.0000
1.50 0.1075 0.0675 0.0525 0.0375 0.0250 0.0000
2.00 0.0850 0.0450 0.0350 0.0250 0.0200 0.0000
2.50 0.0850 0.0450 0.0350 0.0250 0.0200 0.0000
3.00 0.0850 0.0450 0.0350 0.0250 0.0200 0.0000
Importance Factor, I
Monumental Building 1.5
Hospital 1.5
Food Storages Structure 1.5
Emergency Relief Stores 1.5
Power Stations 1.5
Water Works 1.5
Radio and Television Facilities 1.5
Places of assembly 1.5
Distribution facilities for gas or petroleum product in urban areas 2.0
Structures for the support of dangerous substances 2.0
Other Structures 1.0