Electronic Pressure Control
Features
Piezo-based pressure controller offers high accuracy control with mini-
mal power consumption less than 40 mA draw at 12 VDC.
Available in 5 standard pressure ranges for precise control.
High-efficiency device produces minimal heat no impact on sensitive
flow measurements.
Can be operated in stand-alone mode to avoid the expense of an
independent control system.
Rapid response time (< 20 ms) gives high level of flow stability.
Physical Properties Tailored to customer pressure/flow and mounting requirements.
Technology:
Multiple Product Configurations Available
Piezo Actuated Proportional Valve
Parker builds each APC around its customers application requirements.
Media: Standard pressure ranges include 03.5 psid up to 0145 psid; flow rates can
Non-Corrosive and Mildly be controlled in the range of 040 slpm of air. Two body styles are also avail-
Corrosive Gases able with 10-32 threaded ports featured on the Upright body and face sealing
Operating Environment: ports incorporated into the Manifold Mount body. Custom configurations are
also possible. Please consult the factory for details.
0 to 55C
Storage Environment: Electrical Performance Characteristics
-40 to 55C Main Power: Pressure Ranges:
Dimensions: 12 VDC +/- 15% 03.5, 07.25, 014.7,
Upright Configuration Input Control: 029, 0145
Length: 1.07" (22.3mm)
0-5 VDC standard Accuracy:
Width: 1.50" (38.0mm)
Consult factory for other options +/- .2% FS Typical
Height: 1.84" (45.6mm)
Monitor Voltage: +/- 1.5% FS Max
Manifold Configuration
Length: 1.07" (22.3mm) 0-5 VDC standard Response:
Width: 2.52" (64.1mm) Current Requirements: < 20 msec (Output volume dependant)
Height: 1.60" (40.6mm)
< 40 mA Linearity:
Porting:
Electrical Requirements: < +/- 1% FS
Face seal, 10-32 Threads
5 pin, 24 harness included Max. Supply Pressure:
Wetted Materials:
200 PSI
Viton, Teflon, Aluminum (Hard
Coat annodized), 303 & 316 Stain- Flow Rates:
less, BeCu, Kapton, Brass, Nylon 040 SLPM (Air)
ElectricalElectrical
ConnectionConnection
APC Pressure Controllers Manual Control
Manual Control
Adjustment
Adjustment ElectricalElectrical
ConnectionConnection
Header He
Dimensions
1.07 / 27.3
1.07 / 27.3 1.80 / 45.7
.15 / 3.9
Electrical Connection
.91 / 23.2
.91 / 23.2 1.60 / 40.6
1.60 / 40.6 1.80 / 45.7
Manual Control
Electrical Connection Adjustment Electrical Connection Header .15 / 3.9 .30 / 7.6 .15 / 3.9
Electrical Connection 4X 0.15/3.8
4X 0.15/3.8
Thru Manual
Thru .05 / 1.3.05 / 1.3
Control
.59 / 15.1 .81 / 20.5
.81 / 20.5
Mounting Mounting
Manual Holes
Control Holes
Adjustment Electrical Connection Header
Electrical Connection Header
2X 0.13/3.4 .30 / 7.6
.30 / /7.6
1.07 27.3
Adjustment
.59 / 15.1
.59 / 15.1
1.07 / 27.3 2X 0.13/3.4 1.07 / 27.3
2X 0.13/3.4 1.07 / 27.3
.91 / 23.2 1.60 / 40.6
2X Face-Seal 2X Face-Seal 1.07 /4X27.3
1.07 / 27.3 0.15/3.8 Thru .05 / 1.3 .81 / 20.5
O-Ring Gland O-Ring
.91 / 23.2
Gland.91 / Mounting
23.2 Holes
1.60 / 40.6
1.60 / 40.6 1.50 / 38.0 2X 10-322X 10-32
Uses 2-009 Uses Size2-0094XSize
0.15/3.8 Thru
4X 0.15/3.8 Thru
.05 / 1.3
Mounting Holes
.05 / 1.3
.81 / 20.5
.81 / 20.5 Fitting Ports
1.50 / 38.0
Fitting Ports
O-Rings
2X Face-Seal
O-Ring Gland
O-Rings Mounting Holes 2X 10-32
1.50 / 38.0
(see note(see
below)
note below)
5 Output Monitor Green 0-5 Volts DC
Piezo Note: To use Manual Control, can
Note: To use Manual Control, short together pins 3 and 4. The pressure
shortthen
Central Controller
together pins 3 and
be manually 4. turning
set by The pressure
the screw of the Manual Control to set
Stand
8 alone
Pressure
7 6
can then be manually set by turning
the desired output pressure. 5
the screw
the desired outputof pressure.
the Manual Control to set
4 3
Controller
Application
Connection
Connection
Details Details
Pin Description
Pin Description Color Wire Color Notes
Header WireHeader Notes
To Application 1 +VDC
1 +VDC Red Red 8-14 Volts DC8-14 Volts DC Power
Power
via Application-Specific 2 Common
2 CommonBlack Black
Pressure Restrictor 0-5mA
0-5 V or 4-20 V or
DC4-20 mA DC Option
Option
3 Control
3 Input Control Input
Blue Blue(Specify when
Source (Specify when ordering)
ordering)
4 Input Monitor
Input4Monitor Yellow Yellow
5 Output Monitor
Output5 Monitor Green Green 0-5 Volts DC0-5 Volts DC
Note: To useNote:
Manual
To use
Control,
Manual
short
Control,
together
short
pins
together
3 and 4.
pinsThe
3 and
pressure
4. The pressure
can then becanmanually
then beset
manually
by turning
set the
by turning
screw ofthe
thescrew
Manual
of the
Control
Manual
to set
Control to set
the desired the
output
desired
pressure.
output pressure.
Ordering Information
8 8 7 7 6 6 5 5 4 4
part number
Pressure Range 0-145 PSI 0-145 PSI 0-15 PSI 0-145 PSI 0-15 PSI
Material Viton Viton Viton Viton Viton
Effective Orifice (in.) 0.065 0.010 0.030 0.003 0.010
Power 12 VDC 12 VDC 12 VDC 12 VDC 12 VDC
Mounting Fittings Fittings Fittings Fittings Fittings
Control 0 - 5 volts 0 - 5 volts 0 - 5 volts 0 - 5 volts 0 - 5 volts
Bleed Orifice None None None None None
1 Standard Configurations have a slight constant bleed to atmosphere to accurately control pressure and are typically used to pressurize closed volumes of inert gasses.
Alternate Configuration are typically selected for gas flow applications and do not have an internal bleed.
2 Control starts at approximately 10% of full scale control voltage and pressure rating allowing for positive shuttoff.
Pressure control may not be possible below 10% of full scale rating.
NOTE: Please consult Parker Precision Fluidics for other considerations. For more detailed information, visit us on the Web.