You are on page 1of 3

MostWidelyAcceptedandTrusted

ICCESReport
ESR1961
ICCES|(800)4236587|(562)6990543|www.icces.org Reissued06/2017
000 Thisreportissubjecttorenewal06/2019.


DIVISION:070000THERMALANDMOISTUREPROTECTION
SECTION:072100THERMALINSULATION

SECTION:078416ANNULARSPACEPROTECTION

REPORTHOLDER:

THEDOWCHEMICALCOMPANY

200LARKINCENTER


1605JOSEPHDRIVE

MIDLAND,MICHIGAN48674

EVALUATIONSUBJECT:


GREATSTUFFGAPS&CRACKS,GREATSTUFFPROMULTIPURPOSEBLACKINSULATINGFOAMSEALANT,
GREATSTUFFMULTIPURPOSEBLACKINSULATINGFOAMSEALANT,GREATSTUFFFIREBLOCK,GREAT
STUFFWINDOW&DOOR,GREATSTUFFBIGGAPFILLER,GREATSTUFFPROGAPS&CRACKS,
CONTRACTORGRADEINSULATINGFOAMSEALANTGAPFILLER,GREATSTUFFPROWINDOW&DOOR,
CONTRACTORGRADEINSULATINGFOAMSEALANT
DOOR&WINDOW,ANDENERFOAM

LookforthetrustedmarksofConformity!

2014RecipientofPrestigiousWesternStatesSeismicPolicyCouncil
(WSSPC)AwardinExcellence ASubsidiaryof

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not
specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a
recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.

Copyright2017ICCEvaluationService,LLC.Allrightsreserved.
ICC-ES Evaluation Report ESR-1961
Reissued June 2017
This report is subject to renewal June 2019.

www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council

DIVISION: 07 00 00THERMAL AND MOISTURE sealant is recognized for use as an alternative to the
PROTECTION methods prescribed by the code for maintaining the
Section: 07 21 00Thermal Insulation integrity of penetrations of fireblocking.
Section: 07 84 16Annular Space Protection
3.0 DESCRIPTION
REPORT HOLDER: 3.1 General:
The foam plastic products described in this report are
THE DOW CHEMICAL COMPANY single-component, polyurethane foam sealants that
200 LARKIN CENTER expand to take the shape of cracks and voids. The foam
1605 JOSEPH DRIVE sealant has a flame-spread index of less than 25 and a
MIDLAND, MICHIGAN 48674 smoke-developed index of less than 450 when tested in
(866) 583-2583 accordance with ASTM E84. The packaging consists of a
straw, gun or cylinder foam delivery configuration. The
EVALUATION SUBJECT: foam has been tested in accordance with ASTM E814
(modified) to establish that the integrity of the fireblocking
GREAT STUFF GAPS & CRACKS, GREAT STUFF is maintained when the fireblocking is penetrated.
PRO MULTIPURPOSE BLACK INSULATING FOAM
SEALANT, GREAT STUFF MULTIPURPOSE BLACK 3.2 Great Stuff Gaps & Cracks, Great Stuff
INSULATING FOAM SEALANT, GREAT STUFF Multipurpose Black Insulating Foam Sealant, Great
FIREBLOCK, GREAT STUFF WINDOW & DOOR, Stuff Fireblock and Great Stuff Pro Multipurpose
GREAT STUFF BIG GAP FILLER, GREAT STUFF Black Insulating Foam Sealant:
PRO GAPS & CRACKS, CONTRACTOR GRADE A minimally expanding foam plastic sealant. It is provided
INSULATING FOAM SEALANT GAP FILLER, GREAT in aerosol cans.
STUFF PRO WINDOW & DOOR, CONTRACTOR
GRADE INSULATING FOAM SEALANT DOOR & 3.3 Great Stuff Window & Door:
WINDOW, AND ENERFOAM A low-pressure-build, expanding foam plastic sealant. It is
provided in aerosol cans.
1.0 EVALUATION SCOPE
3.4 Great Stuff Big Gap Filler:
Compliance with the following codes:
A triple expanding foam plastic sealant. It is provided in
2015, 2012, 2009 and 2006 International Building aerosol cans.

Code (IBC)
3.5 Great Stuff Pro Gaps & Cracks and Contractor
2015, 2012, 2009 and 2006 International Residential Grade Insulating Foam Sealant Gap Filler:
Code (IRC)
A minimally expanding foam plastic sealant. It is provided
Properties evaluated: in aerosol cans.
Surface-burning characteristics 3.6 Great Stuff Pro Window & Door and Contractor
Annular space protection Grade Insulating Foam Sealant Door & Window:

2.0 USES A low-pressure-build, minimally expanding foam plastic


sealant. It is provided in aerosol cans.
Great Stuff Gaps & Cracks, Great Stuff Pro
Multipurpose Black Insulating Foam Sealant, Great Stuff 3.7 Enerfoam:
Multipurpose Black Insulating Foam Sealant, Great Stuff A minimally expanding foam plastic sealant. It is provided
Fireblock, Great Stuff Window & Door, Great Stuff Big in aerosol cans.
Gap Filler, Great Stuff Pro Gaps & Cracks, Contractor
Grade insulating Foam Sealant Gap Filler, Great Stuff 4.0 INSTALLATION
Pro Window & Door, Contractor Grade Insulating Foam Installation of the foam plastic sealants must comply with
Sealant Door & Window and Enerfoam are aerosol foam this report and the manufacturers published installation
plastic sealants used to fill cracks and voids in construction instructions. The manufacturers published installation
and the annular space created by the penetration of wood instructions are to be available at the jobsite at all times
fireblocking by pipes and conduits. The foam plastic during installation.

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.

Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 2
ESR-1961 | Most Widely Accepted and Trusted Page 2 of 2

The foam must be installed to completely fill the annular 2012 IBC (Section 717.2 of the 2009 and 2006 IBC) is
space around the penetrations for the full depth of the plate permitted, and to nonfire-resistance-rated construction
that has been penetrated. Use of the foam plastic to fill permitted under the IRC.
cracks is required to observe the following limitations:
5.5 The foam plastic sealants listed in this report are
a. The maximum width of exposed foam or the annular produced in Wilmington, Illinois, under a quality-
space of penetrations to be sealed is not to exceed control program with inspections by ICC-ES.
5
1 /16 inches (33 mm), and the nominal foam thickness
6.0 EVIDENCE SUBMITTED
is not to exceed 3 inches (76 mm).
6.1 Manufacturers descriptive literature.
b. The maximum area of exposed foam must not exceed
2 2
18 square inches per square foot (1250 cm /m ) of 6.2 Report containing results of testing performed in
wall area. accordance with ASTM E84.
5.0 CONDITIONS OF USE 6.3 Report containing results of comparative testing
performed in accordance with a modified version of
The Great Stuff,Enerfoam and Contractor Grade foam
ASTM E814.
plastic sealants described in this report comply with, or are
suitable alternatives to what is specified in, those codes 6.4 Report containing results of testing performed in
listed in Section 1.0 of this report, subject to the following accordance with UL 1715.
conditions:
6.5 Report containing results of testing performed in
5.1 Materials and methods of installation must comply accordance with ASTM D1622 and ASTM D1623.
with this report and the manufacturers published
6.6 A quality control manual.
installation instructions. In the event of a conflict
between the manufacturers published installation 7.0 IDENTIFICATION
instructions and this report, this report governs. The Great Stuff, Enerfoam and Contractor Grade foam
5.2 The sealant is not to be used in applications where plastic sealants described in this report must be identified
exposed to sunlight or weather. by a label bearing the manufacturers name (The Dow
Chemical Company), the product type, and the evaluation
5.3 A thermal barrier is not required when installation report number (ESR-1961).
complies with Section 4.0 of this report.
5.4 Use of the sealants is limited to use in
nonfire-resistance-rated partitions where combustible
fireblocking required in Section 718.2 of the 2015 and

You might also like