You are on page 1of 1

if more than 3000 mm.

span provide stiffener column


3000 3000 3000
THICKNESS OF WALL
2 - 16 mm MAIN
BARS

3000 PSI
250

10 mm STIRRUP
SPACE @ 300

STIFFENER COLUMN PLAN VIEW

MAIN BEAM N.T.S.


if more than 3000 mm. height

STIFFENER COLUMN @

STIFFENER COLUMN @
3000
provide stiffener beam

EVERY 3000 mm

EVERY 3000 mm

CHB CHB CHB


MAIN COLUMN

MAIN COLUMN

STIFFENER BEAM @ EVERY 3000 mm HEIGHT STIFFENER BEAM @ EVERY 3000 mm HEIGHT STIFFENER BEAM @ EVERY 3000 mm HEIGHT

THICKNESS OF WALL
STIFFENER COLUMN @

STIFFENER COLUMN @
3000

2 - 16 mm MAIN
EVERY 3000 mm

EVERY 3000 mm

BARS
CHB CHB CHB 3000 PSI
250

10 mm STIRRUP
SPACE @ 300

STIFFENER BEAM SECTION VIEW


N.T.S.

MAIN BEAM

TYPICAL DETAIL OF STIFFENER


COLUMN & BEAM FOR MASONRY
N.T.S.