You are on page 1of 2
ESENNAR TRANSFORMERS PRIVATE LIMITED UNIT - II Office & Works: Plot No. 2, Phase —|, IDA, Pashamailaram, Medak (Dist.) Telangana state India — 502 307. ‘TEL : 224205 / 224206 FAX : 08455-224173, CELL : 94400 80716 / 98488 66344 TRANSFORMER TEST CERTIFICATE Customer : MIS. ABIJIT SOLAR ENERGY PVT. LTD., VELTOOR, NEAR ADAKKAL POLICE STATION, MAHBUBNAGAR (DIST), TELANGANA — 509376. AIC. VISA POWERTECH PVT. LTD., wo. : ET2-3754 SI. No: ET2-3754 Standard Ref: IS: 2026-2011 Customer Order Ref. : P.O.NO: PO/2016-17/413, DT:27.10.2016 With upto date amendments Rating KVA 2500 3Phase SO HZ Cooling: ONAN Vector Group : Ynd11d11 Voltage Ratio in Volts Rated Amps Temp. Rise 2 50/5S°C. HV: 33000 V HV : 43.73 Lvt: 380 V LVI: 1899.23 A Lv2: 380V LV2; 1899.23 A Tapings 1 +5% to -5% in Steps of 2.5 % on HV Bil (1.2/50 MS Wave) RATIO TEST: HV ~ LV1 (Star - Delta) (nd) Tap Polarity and Switch (1) (2) (3) ) 3) Vector Position Relationship a 5267 51.41 50.16 4890 47.65 Tuans [PhaseV lier sin ease woo ares er W | s267 5141 50.16 48.90 47.85 RATIO TEST : HV - LV2 (Star - Delta) (Yndt1) Tap Polarity Switch and Position (1) (2) (3) (4) 6) Vector Relationsh ip — 8267 51.41 50.16 = 48.90 47.65 TuRNS | PhaseV = Lys 8) ser stat 80.18 48.90 65 =" 5267 61.41 50.18 4890 47.65 WINDING RESISTANCE AT 75 Deg. C: (a) HV Winding. 39 Ohms BetweenTerminals: ‘Average per phase (b) LVI Winding. 0.00141 Ohms Between Terminals: ‘Average per phase (©) LV2 Winding. 10149 Ohms Between Terminals: ‘Average per phase TESTED LOAD LOSS & IMPEDANCE AT 75° C (a) Load Losses Watts 26300 (b) Impedance (HV TO LV) Percentage 6.35 (c)_Impedance (Between LV's)__ Percentage 44.0 NO LOAD LOSS & CURRENT AT RATED VOLTAGE AND AT 60HZ TESTED (a) No Load Losses Watts 2970 (b)__Current Amps 14.02 DIELECTRIC TESTS (a) Separate Source Voltage Withstand Test: HV Winding to LV18 LV2 Winding Core frame & Tank applied 70 KV For 60 Secs. And Withstood OK LV 1Winding to HV & LV2 Winding Core frame & Tank applied 3. KV For 60 Secs. And Withstood OK LV 2 Winding to HV & LV1 Winding Core frame & Tank applied 3_ KV For 60 Secs. And Withstood OK (b) Induced Over Voltage Withstand Te: Applied 2 X Rated Voltage on LV side at 150 cycles for 40 Secs. And Withstood. oK INSULATION RESISTANCE & OIL TEST Oil Test as per IS: 335-1993, HV. Windings to earth 500 MOhms Method IS: 6792 - 1992 LV Windings to earth 500 MOhms, ‘Average B.D. Voltage KV 65 LV2 Wiindings to earth 500 MOhms: 2.5 mm gap setting HV" Windings to LV1 Windings 500 MOhms HV. Windings to LV2 Windings 500 MOhms, LV1 Windings to LV2 Windings 10 MOhms At 30°C Tested By: Date of Test:15.12.2016

You might also like