Professional Documents
Culture Documents
Aprile 2013 LITEC Italia Spa - via Raffaello, 31 - 31021 Mogliano Veneto (TV)
www.litectruss.com info@litectruss.com
LT RC QH40SA
QH40SA
Indice
1 Prescrizioni:.......................................................................................................... 3
2 Descrizione della struttura: ................................................................................... 4
3 Riferimenti normativi:............................................................................................ 6
4 Introduzione: ........................................................................................................ 6
5 Simbologia: .......................................................................................................... 7
6 Materiali: .............................................................................................................. 8
6.1 Riferimenti normativi:..................................................................................... 8
6.2 Identificazione dei materiali: .......................................................................... 8
6.3 Costanti dellalluminio (EC 9 3.2.5):............................................................. 8
6.4 Saldature:...................................................................................................... 8
6.5 Coefficienti di sicurezza parziale del materiale (EC 9 6.1.3 e 8.1.1): ........... 8
7 Calcolo degli elementi strutturali:.......................................................................... 9
7.1 Corrente: ....................................................................................................... 9
7.2 Diagonale:................................................................................................... 12
7.3 Collegamenti saldati: ................................................................................... 14
7.4 Collegamenti con piastre: ............................................................................ 15
8 Ipotesi di calcolo:................................................................................................ 17
9 Tabelle ............................................................................................................... 18
10 Appendice 1: Campo resistente approssimato a flessione e taglio ..................... 27
Pagina 2 / 27 LT RC QH40SA
QH40SA
1 Prescrizioni:
Pagina 3 / 27 LT RC QH40SA
QH40SA
corrente
48x3 mm
diagonale
22x2 mm
Pagina 4 / 27 LT RC QH40SA
QH40SA
Pagina 5 / 27 LT RC QH40SA
QH40SA
3 Riferimenti normativi:
Eurocodice 1 EN 1991-1-1 agosto 2004
Eurocodice 3 EN 1993-1-1 agosto 2005
Eurocodice 9 EN 1999-1-1 maggio 2007
4 Introduzione:
La relazione di calcolo utilizza il metodo semiprobabilistico agli stati limite ultimi.
Secondo tale metodo vengono confrontate le resistenze di calcolo della struttura Rd
con le sollecitazioni di calcolo agenti su di essa Sd, secondo la relazione:
Sd Rd
dove:
Sd: i carichi di progetto Sd derivano da quelli caratteristici, amplificati attraverso i
coefficienti di sicurezza F ( 1);
Rd: le resistenze di calcolo Rd, corrispondenti ad un particolare meccanismo di
rottura, derivano adottando per le resistenze dei materiali i valori caratteristici,
opportunamente modificati attraverso i coefficienti di sicurezza m( 1).
Nella presente relazione di calcolo si determinato il carico ultimo Fult., che quello
massimo di progetto, amplificato del coefficiente di sicurezza F assunto pari a 1.35,
come previsto da EC 1 per i carichi di tipo permanente. Si poi calcolato il carico
massimo ammissibile Famm., che il carico massimo che possibile applicare alla
struttura, al netto del peso proprio.
Ipotesi di calcolo:
le configurazioni di carico analizzate nella presente relazione cos come i
vincoli imposti sono da considerarsi condizioni ideali; quindi lutilizzatore deve
analizzare la struttura alla luce delle reali condizioni di carico/vincolo relative
alla specifica applicazione;
si assume che i carichi applicati siano di tipo statico;
si considera che le saldature vengano realizzate in conformit a UNI EN ISO
15607;
si calcolata la freccia corrispondente ai vari schemi statici, considerando la
combinazione dei carichi agli stati limite di esercizio, assumendo 1 come
coefficiente amplificativo del peso proprio e del carico ammissibile; si
demanda al progettista la valutazione sullaccettabilit;
le tabelle presentate in questa relazione tengono conto della resistenza e
della stabilit locale dei correnti e dei diagonali; si affida al progettista la
valutazione della stabilit globale della struttura;
Pagina 6 / 27 LT RC QH40SA
QH40SA
5 Simbologia:
Pagina 7 / 27 LT RC QH40SA
QH40SA
6 Materiali:
6.4 Saldature:
La saldatura tra correnti e diagonali una saldatura a cordone dangolo con altezza
di gola di 2,5 mm. E' realizzata con procedimento TIG/141 (ISO 4063) e utilizza
come metallo dapporto la lega S Al4043A (EN ISO 18273). La resistenza
caratteristica del cordone di saldatura risultante valutata come f w=190 N/mm2 (EC
9 8.6.3.1 table 8.8). La saldatura tra correnti e piastre di estremit una
saldatura di testa a completo ripristino. La resistenza caratteristica della saldatura
valutata da prove sperimentali come fw=130 N/mm2
Pagina 8 / 27 LT RC QH40SA
QH40SA
7.1 Corrente:
Pagina 9 / 27 LT RC QH40SA
QH40SA
Resistenza a trazione (EC9 6.2.3)
A 424 mm 2 area della sezione
f0 250 MPa tensione di snervamento
M1 1.1 coefficiente di sicurezza
Af 0
N 0, Rd 96.39 kN Resistenza a trazione per snervamento
M1
Anet 424 mm 2 area netta della sezione
fu 290 MPa tensione di rottura
M2 1.25 coefficiente di sicurezza
0 .9 Anet f u Resistenza a trazione per rottura locale (tiene
N u , Rd 88.56 kN
M2 conto della presenza di fori)
Aeff 338 mm 2 area efficace della sezione
fu 290 MPa tensione di snervamento
M2 1.25 coefficiente di sicurezza
Aeff f u Resistenza a trazione per rottura locale (tiene
N u , Rd 78.35 kN
M2 conto della presenza di HAZ)
NRd 78.35 kN Resistenza a trazione del profilo
Pagina 10 / 27 LT RC QH40SA
QH40SA
Resistenza a compressione per instabilit (EC9 6.3.1)
k 0.65 fattore di riduzione per presenza saldature
1
0.87 fattore di riduzione per instabilit
2 2
0 . 5 (1 ( 0 ) 2 ) 0.73
A eff f 0
0.60
N cr
0
0.1 fattore di snellezza limite
2 EJ
N cr 298 kN carico critico euleriano
L20
A 424 mm 2 area della sezione
Aeff 424 mm 2 area effettiva della sezione
f0 250 MPa tensione di snervamento
Imin 107831 mm 4 momento d'inerzia
E 70000 MPa modulo elastico
L0 500 mm lunghezza libera di inflessione
M1 1.10 coefficiente di sicurezza
kAeff f0
Ni, Rd 55.04 kN Resistenza a compressione per instabilit
M1
Pagina 11 / 27 LT RC QH40SA
QH40SA
Resistenza a taglio (EC9 6.2.6)
v 0.6 parametro
Aeff - 0*t - 304 2
mm area sezione efficace
Av=vAeff 182 mm 2 area resistente a taglio
f0 250 MPa tensione di snervamento
M1 1.1 coefficiente di sicurezza
f0
V Rd Av 23.94 kN Resistenza a taglio del profilo
3 M 1
7.2 Diagonale:
Pagina 12 / 27 LT RC QH40SA
QH40SA
Resistenza a trazione (EC9 6.2.3)
Ag 66 mm 2 area della sezione
f0 250 MPa tensione di snervamento
M1 1.1 coefficiente di sicurezza
Ag f 0
N 0 , Rd 14.99 kN Resistenza a trazione per snervamento
M1
Aeff 83 mm 2 area efficace della sezione
fu 290 MPa tensione di snervamento
M2 1.25 coefficiente di sicurezza
Aeff f u Resistenza a trazione per rottura locale (tiene
N u , Rd 19.33 kN
M2 conto della presenza di HAZ)
NRd 14.99 kN Resistenza a trazione del profilo
0 . 5 (1 ( 0 ) 2 ) 1.25
A eff f 0
1.13
N cr
0
0.1 fattore di snellezza limite
2 EJ
N cr 24 kN carico critico euleriano
L20
A 126 mm 2 area della sezione
Aeff 126 mm 2 area effettiva della sezione
f0 250 MPa tensione di snervamento
Imin 6346 mm 4 momento d'inerzia
E 70000 MPa modulo elastico
L0 424 mm lunghezza libera di inflessione
M1 1.10 coefficiente di sicurezza
kAeff f0
Ni, Rd 16.18 kN resistenza a compressione per instabilit
M1
Pagina 13 / 27 LT RC QH40SA
QH40SA
7.3 Collegamenti saldati:
Caratteristiche dei materiali
fw 190 MPa resistenza della saldatura
fu,haz 185 MPa resistenza dell'alluminio al limite HAZ
Pagina 14 / 27 LT RC QH40SA
QH40SA
7.4 Collegamenti con piastre:
Pagina 15 / 27 LT RC QH40SA
QH40SA
Resistenza a rifollamento dello spigot con la spina (EC9 8.5.5 table 8.5)
e1 16.5 mm distanza dal bordo parall. alla forza
e2 17.5 mm distanza dal bordo ortog. alla forza
d0 9 mm diametro foro
d 9 mm diametro spina
t 25 mm spessore spigot
fu 340 MPa tensione di rottura spigot
fusp. 750 MPa tensione di rottura spina
b 0.61 parametro
d 0.61 parametro
k1 2.5 parametro
Mb 1.25 coefficiente di sicurezza
k 1 b f u dt Resistenza assiale del corrente per rifollamento
Fb , Rd 187.00 kN
Mb della forca con la spina
Nel caso di collegamento con bulloni si calcola lo sforzo assiale massimo nel
corrente che provoca la rottura della piastra a flessione e taglio, con riferimento al
seguente schema statico.
Schema statico
e
Sez.A
A
Resistenza della piastra con il collegamento bullonato
e 44.5 mm
f0 168 MPa tensione di snervamento
A 428.5 2
mm area resistente
W 1187 mm 3 modulo resistente
M1 1.1 coefficiente di sicurezza
f0
N Rd ,c
2 2 Resistenza assiale del corrente per rottura della
e 1 15.93 kN
M1 3 piastra
4W 2A
Pagina 16 / 27 LT RC QH40SA
QH40SA
8 Ipotesi di calcolo:
La struttura stata calcolata assumendo che:
- le diagonali sono soggette a sforzo assiale;
- i correnti sono soggetti a sforzo assiale, data la convergenza degli assi delle
diagonali sugli assi dei correnti;
- le saldature di estremit tra piastre e correnti sono soggette a sforzo normale,
taglio e momento flettente, data leccentricit dellultima diagonale.
dove
M 1.35 p. p.
N Rd ,c
q corr 2H
M1
2H
V1.35 p. p.
N Rd , d
q diag 2 sen
V1
2 sen
Nelle tabelle seguenti si considera un peso medio del traliccio di 0.079 kN/m
Pagina 17 / 27 LT RC QH40SA
QH40SA
9 Tabelle
T R A V E A P P O G G IA T A - C A R IC O B A R IC EN T R IC O - C O N N E S SIO N I
QH40SA SP IG O T
UNIFORM. DISTRIBUITO CENTRATOIN MEZZERIA CONCENTRATOAI TERZI CONCENTRATOAI QUARTI CONCENTRATOAI QUINTI
UNIFORMLYDISTRIBUITED CENTREPOINTLOAD SINGLELOAD THIRD POINT SINGLELOAD FOURTH POINT SINGLELOAD FIFTH POINT
span qu. qam. qamL defl. F u. F am. F am. defl. F u. F am. 2F am. defl. F u. F am. 3F am. defl. F u. F am. 4F am. defl.
[m] kN/m kN/m kN mm kN kN kN mm kN kN kN mm kN kN kN mm kN kN kN mm
1 49.3 36.5 36.5 0 49.3 36.5 36.5 0 24.6 18.2 36.5 0 16.4 12.2 36.5 0 12.3 9.12 36.5 0
2 24.6 18.2 36.4 1 38.1 28.2 28.2 1 23.4 17.4 34.7 1 16.4 12.1 36.4 1 12.3 9.1 36.4 1
3 16.3 12.1 36.3 4 29.4 21.8 21.8 3 19.0 14.1 28.1 4 14.7 10.9 32.8 4 12.2 9.06 36.2 4
4 12.2 9.06 36.3 8 23.8 17.6 17.6 7 15.9 11.7 23.5 7 12.6 9.35 28.1 8 10.3 7.65 30.6 9
5 9.3 6.92 34.6 16 19.9 14.8 14.8 11 13.6 10 20.1 12 11.0 8.14 24.4 14 8.6 6.36 25.4 14
6 6.5 4.85 29.1 23 17.1 12.7 12.7 16 11.8 8.74 17.5 19 9.3 6.89 20.7 21 7.3 5.42 21.7 21
7 4.8 3.58 25 31 14.9 11.1 11.1 22 10.4 7.72 15.4 26 8.0 5.94 17.8 28 6.4 4.72 18.9 29
8 3.7 2.74 21.9 41 13.2 9.78 9.78 30 9.3 6.89 13.8 35 7.0 5.21 15.6 37 5.6 4.16 16.6 38
9 2.9 2.16 19.5 52 11.8 8.75 8.75 38 8.4 6.21 12.4 46 6.3 4.63 13.9 48 5.0 3.72 14.9 49
10 2.36 1.75 17.5 65 10.7 7.9 7.9 48 7.6 5.64 11.3 58 5.6 4.16 12.5 59 4.5 3.35 13.4 60
11 1.93 1.43 15.7 79 9.7 7.18 7.18 59 7.0 5.15 10.3 71 5.1 3.76 11.3 72 4.1 3.04 12.2 74
12 1.61 1.19 14.3 94 8.9 6.56 6.56 70 6.4 4.73 9.47 85 4.6 3.42 10.3 86 3.7 2.77 11.1 88
13 1.35 1 13 110 8.1 6.03 6.03 84 5.9 4.37 8.73 101 4.2 3.13 9.4 101 3.4 2.55 10.2 104
14 1.15 0.85 11.9 128 7.5 5.56 5.56 98 5.5 4.04 8.08 118 3.9 2.88 8.64 118 3.2 2.35 9.38 122
15 0.99 0.73 11 146 6.9 5.14 5.14 113 5.1 3.75 7.5 137 3.6 2.66 7.97 136 2.9 2.17 8.67 140
16 0.86 0.63 10.1 167 6.4 4.77 4.77 130 4.7 3.49 6.98 157 3.3 2.46 7.38 155 2.7 2.01 8.04 160
17 0.75 0.55 9.4 188 6.0 4.43 4.43 148 4.4 3.26 6.51 179 3.1 2.28 6.84 175 2.5 1.87 7.47 182
18 0.65 0.48 8.72 211 5.6 4.12 4.12 167 4.1 3.04 6.09 202 2.9 2.12 6.36 197 2.3 1.74 6.96 204
va in crisi il diago nale
va in crisi il co rrente
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-i carichi devono essere applicati nei nodi del traliccio; in caso contrario il massimo carico puntuale
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. Si
demanda al progettista la valutazione della stabilit globale della struttura;
TPL
28
26 QPL
24
22 FPL
20
18
16
14
12
10
8
6
4
2
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
campata (m)
Pagina 18 / 27 LT RC QH40SA
QH40SA
T R A V E A P P O G G IA T A - C A R IC O B A R IC EN T R IC O - C O N N E S SIO N I
QH40SA B ULLO N I
UNIFORM. DISTRIBUITO CENTRATOIN MEZZERIA CONCENTRATOAI TERZI CONCENTRATOAI QUARTI CONCENTRATOAI QUINTI
UNIFORMLYDISTRIBUITED CENTREPOINTLOAD SINGLELOAD THIRD POINT SINGLELOAD FOURTH POINT SINGLELOAD FIFTH POINT
span qu. qam. qamL defl. F u. F am. F am. defl. F u. F am. 2F am. defl. F u. F am. 3F am. defl. F u. F am. 4F am. defl.
[m] kN/m kN/m kN mm kN kN kN mm kN kN kN mm kN kN kN mm kN kN kN mm
1 49.3 36.5 36.5 0 44.5 33 33 0 24.6 18.2 36.5 0 16.4 12.2 36.5 0 12.3 9.12 36.5 0
2 22.2 16.4 32.8 1 22.2 16.4 16.4 1 16.6 12.3 24.6 1 11.1 8.21 24.6 1 9.2 6.84 27.4 1
3 9.8 7.25 21.8 2 14.7 10.9 10.9 2 11.0 8.16 16.3 2 7.3 5.44 16.3 2 6.1 4.53 18.1 2
4 5.5 4.05 16.2 4 10.9 8.09 8.09 3 8.2 6.07 12.1 4 5.5 4.05 12.1 4 4.6 3.37 13.5 4
5 3.5 2.56 12.8 6 8.6 6.4 6.4 5 6.5 4.8 9.6 6 4.3 3.2 9.6 6 3.6 2.67 10.7 6
6 2.4 1.75 10.5 8 7.1 5.26 5.26 7 5.3 3.95 7.89 9 3.6 2.63 7.89 8 3.0 2.19 8.77 9
7 1.7 1.27 8.87 12 6.0 4.44 4.44 9 4.5 3.33 6.66 12 3.0 2.22 6.66 11 2.5 1.85 7.39 12
8 1.3 0.95 7.62 15 5.1 3.81 3.81 12 3.9 2.86 5.71 15 2.6 1.9 5.71 14 2.1 1.59 6.35 15
9 1.0 0.74 6.62 19 4.5 3.31 3.31 16 3.4 2.48 4.96 19 2.2 1.65 4.96 18 1.9 1.38 5.52 19
10 0.78 0.58 5.81 24 3.9 2.9 2.9 19 2.9 2.18 4.36 24 2.0 1.45 4.36 22 1.6 1.21 4.84 24
11 0.63 0.47 5.13 28 3.5 2.56 2.56 24 2.6 1.92 3.85 29 1.7 1.28 3.85 27 1.4 1.07 4.27 29
12 0.51 0.38 4.55 34 3.1 2.27 2.27 28 2.3 1.71 3.41 34 1.5 1.14 3.41 32 1.3 0.95 3.79 34
13 0.42 0.31 4.05 40 2.7 2.02 2.02 33 2.0 1.52 3.03 40 1.4 1.01 3.03 38 1.1 0.84 3.37 40
14 0.35 0.26 3.6 46 2.4 1.8 1.8 39 1.8 1.35 2.7 47 1.2 0.9 2.7 44 1.0 0.75 3 46
15 0.29 0.21 3.21 53 2.2 1.61 1.61 45 1.6 1.2 2.41 54 1.1 0.8 2.41 51 0.9 0.67 2.68 53
16 0.24 0.18 2.86 60 1.9 1.43 1.43 52 1.4 1.07 2.14 61 1.0 0.71 2.14 58 0.8 0.59 2.38 61
17 0.20 0.15 2.53 68 1.7 1.27 1.27 59 1.3 0.95 1.9 69 0.9 0.63 1.9 66 0.7 0.53 2.11 68
18 0.17 0.12 2.24 76 1.5 1.12 1.12 67 1.1 0.84 1.68 77 0.8 0.56 1.68 74 0.6 0.47 1.87 77
va in crisi il diago nale
va in crisi il co rrente
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-i carichi devono essere applicati nei nodi del traliccio; in caso contrario il massimo carico puntuale
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. Si
demanda al progettista la valutazione della stabilit globale della struttura;
TPL
28
26 QPL
24
22 FPL
20
18
16
14
12
10
8
6
4
2
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
campata (m)
Pagina 19 / 27 LT RC QH40SA
QH40SA
T R A V E A P P O G G IA T A - C A R IC O E C C E N T R IC O - C O N N ES S IO N I
QH40SA SP IG O T
UNIFORM. DISTRIBUITO CENTRATOIN MEZZERIA CONCENTRATOAI TERZI CONCENTRATOAI QUARTI CONCENTRATOAI QUINTI
UNIFORMLYDISTRIBUITED CENTREPOINTLOAD SINGLELOAD THIRD POINT SINGLELOAD FOURTH POINT SINGLELOAD FIFTH POINT
span qu. qam. qamL defl. F u. F am. F am. defl. F u. F am. 2F am. defl. F u. F am. 3F am. defl. F u. F am. 4F am. defl.
[m] kN/m kN/m kN mm kN kN kN mm kN kN kN mm kN kN kN mm kN kN kN mm
1 49.2 36.5 36.5 0 38 28.2 28.2 0 20.7 15.4 30.7 0 14.4 10.7 32.1 0 11.1 8.25 33 0
2 24.6 18.2 36.4 1 30 22.2 22.2 1 17.5 12.9 25.9 1 12.6 9.37 28.1 1 10.0 7.4 29.6 1
3 16.3 12.1 36.3 4 24.4 18.1 18.1 3 14.9 11.1 22.1 3 11.2 8.27 24.8 3 9.0 6.67 26.7 3
4 12.1 8.94 35.7 8 20.5 15.2 15.2 6 13.0 9.61 19.2 6 9.9 7.36 22.1 6 8.2 6.04 24.2 7
5 8.5 6.3 31.5 14 17.6 13 13 9 11.4 8.46 16.9 10 8.9 6.6 19.8 11 7.4 5.5 22 12
6 6.2 4.58 27.5 21 15.4 11.4 11.4 14 10.2 7.53 15.1 16 8.1 5.97 17.9 18 6.7 4.96 19.8 19
7 4.6 3.44 24.1 30 13.6 10.1 10.1 20 9.1 6.77 13.5 23 7.3 5.44 16.3 26 5.9 4.36 17.4 26
8 3.6 2.65 21.2 40 12.2 9.02 9.02 27 8.3 6.13 12.3 32 6.7 4.98 14.9 36 5.2 3.88 15.5 35
9 2.8 2.1 18.9 51 11.0 8.14 8.14 36 7.5 5.59 11.2 41 6.0 4.46 13.4 46 4.7 3.49 14 46
10 2.29 1.7 17 63 10.0 7.39 7.39 45 6.9 5.12 10.2 53 5.4 4.02 12 57 4.3 3.16 12.7 57
11 1.89 1.4 15.4 77 9.1 6.76 6.76 55 6.4 4.72 9.44 65 4.9 3.64 10.9 70 3.9 2.89 11.5 70
12 1.58 1.17 14 92 8.4 6.21 6.21 67 5.9 4.36 8.72 79 4.5 3.33 9.98 84 3.6 2.65 10.6 85
13 1.34 0.99 12.9 109 7.7 5.72 5.72 80 5.5 4.05 8.09 94 4.1 3.05 9.15 99 3.3 2.44 9.75 100
14 1.14 0.85 11.8 127 7.1 5.3 5.3 94 5.1 3.76 7.53 111 3.8 2.81 8.43 115 3.0 2.25 9.01 117
15 0.98 0.73 10.9 146 6.6 4.91 4.91 109 4.7 3.51 7.02 129 3.5 2.6 7.79 133 2.8 2.09 8.35 136
16 0.86 0.63 10.1 166 6.2 4.57 4.57 125 4.4 3.28 6.56 149 3.2 2.41 7.22 152 2.6 1.94 7.76 155
17 0.75 0.55 9.4 188 5.7 4.26 4.26 143 4.1 3.07 6.14 170 3.0 2.24 6.71 172 2.4 1.81 7.23 177
18 0.65 0.48 8.72 211 5.4 3.97 3.97 162 3.9 2.88 5.76 193 2.8 2.08 6.24 194 2.3 1.69 6.74 199
va in crisi il diago nale
va in crisi il co rrente
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-i carichi devono essere applicati nei nodi del traliccio; in caso contrario il massimo carico puntuale
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. Si
demanda al progettista la valutazione della stabilit globale della struttura;
26
24 QPL
22
20 FPL
18
16
14
12
10
8
6
4
2
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
campata (m)
Pagina 20 / 27 LT RC QH40SA
QH40SA
T R A V E A P P O G G IA T A - C A R IC O E C C E N T R IC O - C O N N ES S IO N I
QH40SA B ULLO N I
UNIFORM. DISTRIBUITO CENTRATOIN MEZZERIA CONCENTRATOAI TERZI CONCENTRATOAI QUARTI CONCENTRATOAI QUINTI
UNIFORMLYDISTRIBUITED CENTREPOINTLOAD SINGLELOAD THIRD POINT SINGLELOAD FOURTH POINT SINGLELOAD FIFTH POINT
span qu. qam. qamL defl. F u. F am. F am. defl. F u. F am. 2F am. defl. F u. F am. 3F am. defl. F u. F am. 4F am. defl.
[m] kN/m kN/m kN mm kN kN kN mm kN kN kN mm kN kN kN mm kN kN kN mm
1 49.2 36.5 36.5 0 38 28.2 28.2 0 20.7 15.4 30.7 0 14.4 10.7 32.1 0 11.1 8.25 33 0
2 22.2 16.4 32.8 1 22 16.4 16.4 1 16.6 12.3 24.6 1 11.1 8.21 24.6 1 9.2 6.84 27.4 1
3 9.8 7.25 21.8 2 14.7 10.9 10.9 2 11.0 8.16 16.3 2 7.3 5.44 16.3 2 6.1 4.53 18.1 2
4 5.5 4.05 16.2 4 10.9 8.09 8.09 3 8.2 6.07 12.1 4 5.5 4.05 12.1 4 4.6 3.37 13.5 4
5 3.5 2.56 12.8 6 8.6 6.4 6.4 5 6.5 4.8 9.6 6 4.3 3.2 9.6 6 3.6 2.67 10.7 6
6 2.4 1.75 10.5 8 7.1 5.26 5.26 7 5.3 3.95 7.89 9 3.6 2.63 7.89 8 3.0 2.19 8.77 9
7 1.7 1.27 8.87 12 6.0 4.44 4.44 9 4.5 3.33 6.66 12 3.0 2.22 6.66 11 2.5 1.85 7.39 12
8 1.3 0.95 7.62 15 5.1 3.81 3.81 12 3.9 2.86 5.71 15 2.6 1.9 5.71 14 2.1 1.59 6.35 15
9 1.0 0.74 6.62 19 4.5 3.31 3.31 16 3.4 2.48 4.96 19 2.2 1.65 4.96 18 1.9 1.38 5.52 19
10 0.78 0.58 5.81 24 3.9 2.9 2.9 19 2.9 2.18 4.36 24 2.0 1.45 4.36 22 1.6 1.21 4.84 24
11 0.63 0.47 5.13 28 3.5 2.56 2.56 24 2.6 1.92 3.85 29 1.7 1.28 3.85 27 1.4 1.07 4.27 29
12 0.51 0.38 4.55 34 3.1 2.27 2.27 28 2.3 1.71 3.41 34 1.5 1.14 3.41 32 1.3 0.95 3.79 34
13 0.42 0.31 4.05 40 2.7 2.02 2.02 33 2.0 1.52 3.03 40 1.4 1.01 3.03 38 1.1 0.84 3.37 40
14 0.35 0.26 3.6 46 2.4 1.8 1.8 39 1.8 1.35 2.7 47 1.2 0.9 2.7 44 1.0 0.75 3 46
15 0.29 0.21 3.21 53 2.2 1.61 1.61 45 1.6 1.2 2.41 54 1.1 0.8 2.41 51 0.9 0.67 2.68 53
16 0.24 0.18 2.86 60 1.9 1.43 1.43 52 1.4 1.07 2.14 61 1.0 0.71 2.14 58 0.8 0.59 2.38 61
17 0.20 0.15 2.53 68 1.7 1.27 1.27 59 1.3 0.95 1.9 69 0.9 0.63 1.9 66 0.7 0.53 2.11 68
18 0.17 0.12 2.24 76 1.5 1.12 1.12 67 1.1 0.84 1.68 77 0.8 0.56 1.68 74 0.6 0.47 1.87 77
va in crisi il diago nale
va in crisi il co rrente
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-i carichi devono essere applicati nei nodi del traliccio; in caso contrario il massimo carico puntuale
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. Si
demanda al progettista la valutazione della stabilit globale della struttura;
26
24 QPL
22
20 FPL
18
16
14
12
10
8
6
4
2
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
campata (m)
Pagina 21 / 27 LT RC QH40SA
QH40SA
T R A V E A S B A LZ O - C A R IC O B A R IC EN T R IC O - C O N N E S SIO N I
QH40SA S P IG O T
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-i carichi devono essere applicati nei nodi del traliccio; in caso contrario il massimo carico puntuale
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. Si
demanda al progettista la valutazione della stabilit globale della struttura;
16
CPL
Carico ammissibile (kN)
14
12
10
8
6
4
2
0
1 2 3 4 5 6
campata (m)
Pagina 22 / 27 LT RC QH40SA
QH40SA
T R A V E A S B A LZ O - C A R IC O B A R IC EN T R IC O - C O N N E S SIO N I
QH40SA B ULLO N I
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-i carichi devono essere applicati nei nodi del traliccio; in caso contrario il massimo carico puntuale
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. Si
demanda al progettista la valutazione della stabilit globale della struttura;
16 UDL
14
CPL
Carico ammissibile (kN)
12
10
0
1 2 3 4 5 6
campata (m)
Pagina 23 / 27 LT RC QH40SA
QH40SA
T R A V E A S B A LZ O - C A R IC O EC C E N T R IC O - C O N N ES S IO N I
QH40SA S P IG O T
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-i carichi devono essere applicati nei nodi del traliccio; in caso contrario il massimo carico puntuale
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. Si
demanda al progettista la valutazione della stabilit globale della struttura;
UDL
12
CPL
Carico ammissibile (kN)
10
0
1 2 3 4 5 6
campata (m)
Pagina 24 / 27 LT RC QH40SA
QH40SA
T R A V E A S B A LZ O - C A R IC O EC C E N T R IC O - C O N N ES S IO N I
QH40SA B ULLO N I
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-i carichi devono essere applicati nei nodi del traliccio; in caso contrario il massimo carico puntuale
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. Si
demanda al progettista la valutazione della stabilit globale della struttura;
UDL
12
CPL
Carico ammissibile (kN)
10
0
1 2 3 4 5 6
campata (m)
Pagina 25 / 27 LT RC QH40SA
QH40SA
QH40SA C A R IC O D I P UN T A B A R IC E N T R IC O
-qu. o Fu. il carico ultimo, al netto del peso proprio, da confrontare con i carichi amplificati di progetto;
-qam or Fam. il carico massimo ammissibile, al netto del peso proprio, da applicare al traliccio;
-questa tabella si riferisce ad un carico baricentrico, applicato simmetricamente sul traliccio;
applicato su un corrente tra due nodi successivi non deve essere superiore a 1,5 kN;
-la presente tabella tiene conto della resistenza e dellinstabilit locale dei correnti e dei diagonali. La
stabilit globale valutata secondo lo schema riportato sopra;
100.00
90.00
80.00
Carico ammissibile (kN)
70.00
60.00
50.00
40.00
30.00
20.00
10.00
0.00
3 4 5 6 7 8 9 10 11 12
altezza (m)
Pagina 26 / 27 LT RC QH40SA
QH40SA