Parker operates 309 manufacturing locations worldwide. Parker Hannifin Headquarters, Cleveland, Ohio
1 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
Parker Global
A Partnership approach
Whether youre a utility, independent power producer or involved in
Standards and
Engineering, Procurement or Construction (EPC), involving us early on Certifications
can frequently speed the process and reduce costs. As a collaborative
partner, we work one-on-one with you to createand deliver:
Custom engineered original equipment solutions utilizing our
completerange of proven products
Technology advances that are smaller, lighter, safer, sustainable,
moreenergy efficient, and highly reliable
Need Support?
Contact us at
EPC@PARKER.COM
3 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
Tube Fittings for Rigid Tubing & Hydraulic Hose Tube Clamping System
EO-3 Fitting System Parker Snap-Trap
EO-3 Fittings feature a unique The Innovative Clamp is designed to
Tapered threading technology help eliminate corrosion while radically
and Indicator ring which provides simplifying the installation & maintenance
a visible confirmation of proper of Instrumentation tubing. Snap-trap
assembly eliminating leakage due unique one-piece design allows quick and
to under-made connections. easy fitting to the cable trays, brackets.
New formed tube design eliminates The clamp will fit slotted cable trays with
tube blow-out failures. No torque various dimensions.
spanner required.
Parker offers two types of coating technology for superior corrosion resistance
Parker ToughShield Parker Suparcase
Corrosion Plating for Tube Fittings and Adaptors Surface Treatment for
Instrumentation Tube Fittings
In neutral salt spray ASTM B117 tests conducted by
an outside testing center, Parker steel fittings and The Parker Suparcase surface
adapters plated with ToughShield (TS1000) outlasted treatment is an unique process
the SAE corrosion standard and the competitions that allows stainless steels and
plating. TS1000 offers unmatched corrosion protection other alloys to be hardened without
at no additional cost, affecting, and even increasing, the
withstanding the corrosion resistance of the given
harshest operating materials. Parker has been using
environments, the proprietary Suparcase process
particularity those that to surface harden stainless steel
promote the rapid ferrules for approximately 20 years.
onset of red and white The process achieves a carbon
rust. Since corrosion supersaturated surface layer by
causes both direct altering the oxide passive layer on
and indirect economic the surface of the stainless steel,
losses, protecting without any detrimental effects.
fittings and adapters
Improved Hardness
with durable,
high-quality plating Hardness Test Suparcased
dramatically reduces samples are at least 250% harder
replacement cost and than their untreated counterparts.
downtime. See the
results for yourself.
5 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
Manifolds Manifolds Condensate Pots
Parker PGI 2,3, 5-Valve Coplanar Parker PGI 2- Valve Block & Parker COND Series
Manifold Bleed Manifold Valve New range of condensate
Our coplanar manifold For inline instrument pots from Parker have
mounts directly to a mounting, our line of two- been designed to trap
Emerson 3051 Series valve manifolds provide any foreign material from
Coplanar transmitter process isolation, pressure small bore tubing systems,
eliminating the need for relief, calibration, or sample preventing damage to
a coplanar flange. The obtainment ports for sensitive instrumentation
Global-style manifold affords maximum robust, simplified installation. components. Condensate
shut-off, robust stems, pinned The Low-Torque Grafoil pots are available in a range of
bonnets and two mounting holes stem seal and proprietary assembly materials and have been designed in
for connecting to bracket mounts. technique reduces opening and accordance with ASME VII Div 1 as
closing forces by 50% when well as CE marked to PED 97/23/EC.
Bellows Seal Valve compared against competitors valves.
Parker PGI Series 3/8" Bore Flow Elements
Our Bellows seal Manifolds Mass Flow Meter
valve is designed FEMF Series Double Block & Veriflo 500/600 Series II Mass
with a metal bel- Bleed Monoflange Manifold Flow Meter
lows between the The Monoflange The Series II produces
stem and body manifold range is expanded flow ranges
as a primary seal. designed to replace (from 0.014 0.7 ml/min
This eliminates two leakage paths, conventional, multiple- up to 33 1670 l/min)
providing a clear advantage over valve installations that and can be factory
traditional packed seal valves. Zero currently interface with configured to include
fugitive emissions is also achieved by pressure measuring up to eight gas and
this configuration. Standard Grafoil systems. By combining primary and flow range combinations
back-up packing and backseating secondary valves into one compact with max operating
valve stem provide additional safety. manifold, leak paths are significantly pressures up to 6000 PSIG.
reduced. These products meet class In addition to standard
Severe Service Manifold Valves A of ISO 15848 standard for fugitive signals and RS232 connection,
Parker PGI DBB Series Double emissions as well as ANSI/ASME DeviceNet, Profibus-DP and
Block & Bleed Valves B31.1, B16.34 and B16.5 codes. Modbus communication protocols
The DBB series is are available. Flow Parameter
designed for high Seal Pots Adjustment (FPA) feature allows
temperature and severe Parker MMHMPS Series greater user configuration while
service applications Parker seal pot line maintaining high accuracy with more
offering a simplified was designed for than 180:1 effectiveness range.
transition from process instrumentation systems
piping to instrumentation. requiring an open seal
This globe-style valve such as toxic, corrosive
provides maximum or high temperature
shut-off, using a ceramic Ball-tip stem service. An immiscible
on the process valve and needle tip seal fluid is used to form
stem on the bleed valve to reduce leak a barrier between the
paths. Offering includes direct mount manifold and instrument (due to
on 2-1/8" center Weldolets and density difference between seal
flange mounting. Designed to meet fluid and process media).
ASME B31.1 and B31.3.
7 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
NATURAL GAS MONITORING AND MEASUREMENTS
Gas Chromatgraph 4-Valve can create large economic gains or Pulsation Testing
Manifold losses for both buyers and sellers Detecting Square Root Error and
Parker PGI P3GC4S Series along a natural gas pipeline system. Gauge Line Errors in Natural Gas
Gas Manifold Industry studies have proven the Measurement
existence of flow and/or pulsation-
This four valve Parkers SRE-6
induced GLE in traditional, remotely
manifold is an and GLE-6
tubed meter installations. Pulsation
economical indicators are
and resulting SRE creates a high
choice for test devices
probability that GLE is present within
changing carrier designed
your measuring systems. These highly
gas cylinders for to quantify
accredited studies concluded that
chromatograph without Square Root
transmitters or EFM should be close
interruption of gas flow. Rated up and Gauge
coupled to the orifice taps with equal
Line Errors in SRE 6
To 6,000 PSI. Roddable pattern or length, large bore (0.375 inch I.D. or
natural gas
Blocks and Globe pattern for Purges. greater), constant diameter gauge
orifice flow
Bore sizes: 3/16" (Blocks) and 1/8" lines to minimize or eliminate GLE.
measurement.
for Purges.
PGI Internationals patented They identify
Parker PGI Direct-Mount Direct-Mount Systems (DMS) were inaccuracies
developed in response to requests caused by
Systems (DMS)
byleading gas transmission compressor
Flange to Flange continuous companies for a safe, efficient induced GLE-6
connection technology that method of close coupling EFMs pulsation and
eliminates NPT connections andtransmitters to orifice fittings differential pressure discrepancies.
and leak paths andthus eliminating or reducing
All necessary calibration equipment,
Why Direct-Mount? theeffects of Gauge Line Error from
connections, hardware and fittings
accurate measuring systems.
Pulsation created by areincluded.
compressors, flow Reduce Installation Costs and
control valves, Increase Safety
regulators and DMS enables a wide range of
some piping instruments to be directly mounted
configurations may to piping systems either horizontally
create unacceptable or vertically. DMS reduces installation
levels of Square Root cost and heat trace requirements as
Error (SRE) and/or well as the number of connections
resulting Gauge Line and potential leakage points.
Error (GLE). Pulsation at the orifice
meter is a major source of lost and
unaccounted for natural gas, which
9 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
HEAT TRACE LINES
Heat Trace Tube Bundles Instrumentation Enclosures
Parflex Multitube Pre-traced, Parflex HES Series Heated Enclosures
Pre-insulated Tube Bundles HES Heated Enclosure systems are
Parker offers a full line of designed using Fiber Reinforced
Constant Watt Polyester (FRP) in either split diagonal
pre-insulated tube bundles
designed for impulse, condensate, or panel board styles. IP65 rated with
sample transport and process Self-Regulating
two seal mechanisms; EPDM and
measurement. Reduce field heat tongue & groove. Single, double or
tracing installation costs with our triple instrument styles available
seamless extruded jacket, including Drawing packages and
Steam Purge
continuous length, pre-insulated instrument tag numbers.
tube bundles. Parflex continuous length tube bundles provide
The manifolds, instruments (sourced
freeze protection, temperature maintenance and meet
or free-issued), fittings and heating
personnel safety requirements. Self-regulating, constant-
systems can be pre-fitted by Parkers assembly service
wattage, mineral insulated and steam traced bundles,
team and delivered fully pressured tested and certified, so
designs for both intermittent and continuous steam
enclosures arrive ready to be installed, saving valuable in
blow-down, and elevated process temperatures which
field assembly and installation time and cost.
require 316H stainless steel are available.
11 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
Air Dryers Three Screw Pumps Fluid Transfer Pumps
domnick hunter Pneudri Heatless Parker SWAT and SWATB16 Series Positive Displacement Lobe Pump
and Heat Dessicant Dryers Three Screw Pumps Parker has
Parkers three-screw developed an
pumps arepositive new 3" positive
displacement axial displacement
flow pumps lobe with
designed to centrifugal boost.
manage low to high Design includes a high
viscosity fluids up performance direct AC induction
to 100 bar in Power motor without a need for a gearbox.
The Pneudri range of regenerative Plant applications including oil Compatible with fluids such as liquid
desiccant dryers remove water vapor circulation, cooling and filtration. fuels, hydraulic and lube oils, water and
from the compressed air supply to Can be used on a wide variety of fluids coolant. Flow rates up to 380 GPM @
create clean, oil-free, dry compressed such as mineral oil, synthetic fluids, 80 psi.
air in compliance with ISO 8573-1 lubrication oils and fuel oils. Key Features:
standards. Our lightweight, modular
C
ompact pump with only three Continuously Dry Runnable and
design eliminates the need for complex
rotating parts and one shaft seal Self-priming
valving and interconnect piping which
is used in conventional twin tower Extremely low noise and Reversible Flow Direction
designs. Flow rates up to 1381 cfm. pulsationdesign
Cavitation Resistant
Custom skid packages available per High flow capabilities up to
customer requirements. 1,320 GPM Turbine Oil Coalescing System
Manufactured according to API 676 Parker Velcon TOC Series
Condensate Drains The TOC
Hyperdrain Zero Air Loss Low Voltage Variable series
Electronic (HDE-X) and Zero Air Frequency Drive units
Loss Mechanical (HDF) Drains Parker AC10 (UL Listed) VFD combine
HDE-X series are the Parker's
Parker
most advanced latest
designed
intelligent drains coalescing
the new
automatically and filtration
AC10 to
continuously alter technology and microglass filter media
be a
thedrainage pattern to restore oil to an ISO cleanliness of
simple,
according to the 14/11 or better while continuously
cost-effective VFD for basic open loop
conditions. An alarm removing free and emulsified water
v/F or sensorless vector control for
warns against any down to 150 ppm or less. Our system
induction and PMAC motors. PLC or
malfunction. design removes water and dirt from the
RS485 / Modbus communications port
turbine lubrication oil in three stages.
HDF Series drains are standard. Conformal coating allows the
Particulate solid contaminants are
compact and highly product to meet IP66 / NEMA 4X and
removed in the pre-filter stage, free
reliable float controlled 3C3 environments.
andemulsified water is removed in
condensate drains. Manual drain thesecond filter/separator stage, and
valve and operational check fitted as then the final polishing stage using
standard. Zero power consumption as synthetic media elements to remove
no power supply is required. fine particles.
13 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
PROCESS ENGINEERING
INDUSTRIAL WATER FILTRATION SYSTEMS
Seawater Reverse Osmosis (SWRO) Desalination Systems
Parker Water Purification SR Series
Parker Water Purification engineers seawater reverse osmosis (SWRO)
desalination systems utilizing the latest technology for low pressure
operation. System is designed for high salt rejection with energy recovery
integrated into each system. On-skid booster pump, 500 gallon CIP and
permeate flush system are standard. This single pass SWRO system is
capable of a nominal capacity of 350-400 M3D.
15 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
Ultrafiltration Systems (UF) Pretreatment Filtration Systems Degasification System
Parker Water Purification Parker Twin Filter Water Purification
UHF Series IMF Media Filtration Membrane Contactors
Parker Water Parker Twin Filter Media Parker Water Purification
Purification is Filtration systems offer Membrane Contactors
specialized in multi-media performance (MC) or Gas Transfer
providing and are specifically membranes incorporate
ultrafiltration (UF) engineered with media innovative degassing
pretreatment layers that are optimized technology to remove
systems using a to remove particulate dissolved gases such as
variety of natural matter from the feed CO2 for ultrapure water.
source waters stream ahead of the Our design utilizes micro
and industrial wastewaters. UF hollow cartridge filtration system porous hydrophobic
fiber membranes are provided in two polypropylene
A proprietary mix and measure of
configurations, outside-in (O/I) PVDF or membranes, providing a
media targets particulate matter such
inside-out (I/O) multi-bore MPES. Both reliable and simple solution while
as turbidity and suspended solids that
types of UF membranes are proven eliminating the need for caustic
otherwise overload the micron filtration
durable with high membrane integrity chemical injection systems.
array of an RO system. In addition,
and low fouling. System flow rates up
the advanced media design reduces Condensate Pre-Filtration
to 220 GPM capacity
iron, manganese and organics in the
Parker dominic hunter
RO-EDI Ultrapure feed stream.
ParMax Large Diameter Vessels
Demineralized Water (UPW) Electrodeionization and Cartridges
Parker Water Purification (EDI) Treatment The best of large
DM Series Parker Water Purification diameter
Parker DM and pleated
EDI Series
Series Reverse technologies
Parker Water are combined
Osmosis
Purification in Parkers
Electrodeion-
EDIsystems ParMax Large
ization system
remove trace Diameter Filter Vessels are designed
provide
ionic salts and to ASME code in stainless steel or
ultrapure
silica from carbon steel construction. Designed to
demineralized
thereverse work with ParMax filter cartridges that
water from
osmosis (RO) permeate resulting in handle flows up to 500 GPM (1,892
brackish water sources. Combining
ultrapure water up to 18 megohm LPM), these 60" length high-flow
the latest technologies of RO with EDI
resistivity with a high rejection of capacity vessels offer significant size
polishing the system can produce up to
soluble ionic load up to 98%. Our and capital cost reduction compared
(18) megohm of ultrapure water.
continuous and chemical-free design with vessels containing conventional
Standard packaged units offer a provides an economical treatment size filter cartridges. ParMax holds up
capacity range from 25-140 GPM solution that can eliminate the to 19 cartridges with flow rates up to
(6-32 m3/hr) utilizing 1 to 6 membranes. expensive and hazardous chemicals 9,500 GPM.
The ideal solution to replace used in traditional ino exchange resin
high-maintenance DI beds or trailers. regeneration. Flow rates up to 140
GPM (32 m3/hr) for packaged
systems and 1,000 GPM (225 m3/hr)
for custom engineered solutions Water
recovery up to 99%.
BIOGAS CONDITIONING
Automatic Siloxane Removal Systems (SRS) Biogas Dehumidification Skid Mounted Packages
Parker PpTek BioGas AK (BGAK) Parker Hiross BioEnergy Dehumidification system
Compact, robust and easy
to handle, the Parker skid
solution is a plug & play
biogas dehumidification
package specifically
designed for outdoor
installations and reliable
performance in harsh
operating environments typically found at
Parker PpTek is the world leader in regenerative siloxane Landfill biogas and Anaerobic digester sites.
removal technology using Hydrophobic media technology.
The dehumidification skid has energy efficiency at the
The BioGas AK is ATEX approved Siloxane Removal System
forefront of its design. The in-built flexibility to use a wide
(SRS) installed in the biogas supply line of a gas to energy
range of cooler / chiller combinations ensures the closest
installation, decontaminating landfill and sewage gas of
match to customer requirements thus delivering constant
siloxanes and other VOCs.
dewpoint performance and significantly reduce the water
The skid-mounted, ECU controlled unit uses one of two vapor content in the biogas and partially or completely
parallel housings to clean the gas, capturing the contaminants remove some of the other impurities.
in the media. As the on-line housing becomes saturated,
Available in a range of sizes from 29 1059 scfm (50 to
the gas flow is automatically redirected to the other housing.
1800 Nm3/h) For applications where the system is located
The first is then regenerated automatically while the flow of
downstream of the blower a specially designed gas-to-gas
gas continues uninterrupted to the engine. 5 year media
heat exchange can be supplied.
guarantee (1,820 regenerations).
17 For more information, click here or visit our Energy Resource Guide at parker.com/energyrgna
START-UP COMMISSIONING SERVICES
CUSTOM ON-SITE WORK CONTAINERS ParkerStore Hose Doctor
20 ft & 40 ft Custom Mobile Containers
ParkerStore On-site Mobile Work Container
The Parker On-site Container solution will significantly
reduce the time it takes to obtain critical spares or fabricate
hose assemblies. The highly efficient and mobile container-
based worksites provide all the technology, equipment and
inventory needed for remote fabrication of hose and tube
assemblies as well fittings inventory. Each unit can be
customized with a variety of options to best suit your
specific project or jobsite.
RENTALS AVAILABLE
PHASTITE FOR PIPE PHASTITE FOR TUBE
Non-Welded Pipe Connection Systems Non-Welded Tubing Connection System
Phastite for Pipe and Phastool System Phastite for Tube
Simple assembly process that achieves permanent Revolutionary Phastite tube connections provide an
non-welded, leak-free connections quickly and easily integrated alternative to weld connections and traditional
reducing labor costs. Phastite for Pipe also reduces high pressure fittings. Simply insert your cleaned and
overall post-welding inspection time and cost. The system prepped tubing, then compress the integral collars to their
is well suited for hydraulic oil, water, water-glycol and other stops. Its that simple. Assembly time required for heavy
media for working pressures up to 10,000 PSI. wall tubing is reduced, while costly welding and inspection
are eliminated.