SIERRA

50-400 HORSEPOWER
AIR COOLED
OPTIONAL
LOW AMBIENT - 10F (-23.3C)
SUPPLEMENTARY
INSTRUCTIONS AND
RECOMMENDED SPARES

Before installation and operation of this option,


these instructions should be studied carefully to
obtain a clear knowledge of the option and its
application to the compressor.

RETAIN THESE INSTRUCTIONS WITH UNIT.


This Technical manual contains IMPORTANT
SAFETY DATA and should be kept with the air
compressor at all times.

C.C.N. : 80440548
REV. : C
DATE : OCTOBER 2000
INGERSOLL-RAND COMPANY
TABLE OF CONTENTS

0.0 SAFETY AND WARNINGS

1.0 DESCRIPTION
1.1 PURPOSE
1.2 TOOLS REQUIRED
1.3 GENERAL INFORMATION

2.0 SPACE HEATERS & HEAT TRACING

3.0 AIR FLOW MODULATION

4.0 GENERAL OPERATION


4.1 MAINTENANCE
4.2 ADJUSTMENT
4.3 LOUVER SETTINGS
4.4 LOUVER OPERATION

5.0 PROCESS & INSTRUMENTATION DIAGRAMS


5.1 50-100HP (37-75KW) 54448733
5.2 125-200HP (90-150KW) 39912001
5.3 250-400HP (200-300KW) 54538889

6.0 WIRING SCHEMATICS


6.1 110V-1PH-50HZ AND 120V-1PH-60HZ 39911979
6.2 220V-1PH-50HZ AND 240V-1PH-60HZ 39927488

7.0 FOUNDATION PLANS


7.1 50-100HP 39909809
7.2 37-75KW 39909817
7.3 125-200HP 39907977
7.4 90-150KW 54609771
7.5 250-400HP 54460977
7.6 200-300KW 54542550

8.0 ASSEMBLY DRAWINGS


8.1 50-100HP (37-75 KW) 39899877
8.2 125-200HP (90-150 KW) 39898861
8.3 250-400HP (200-300 KW) 54462155

9.0 SPARE PARTS LIST

1
0.0 SAFETY AND WARNINGS
Refer to 0.0 (Safety and Warnings) in the
Operators/Instruction Manual, Form 88155494 (50-
100 HP / 37-75 KW) or 39929104 (125-200 HP / 90-
300 KW).

Shut down the compressor. Close the Isolation


valve. Relieve the system air pressure. Ensure
what all air pressure has been relieved from the
compressor and air system.

Disconnect power to the compressor before ser-


vicing. Lock and tag all disconnect switches in the
open (off) position (See Figure 0.0-1).

DANGER
HASP
HIGH VOLTAGE

LEVER

TAG

GER
KEY LOCK DAN

FIGURE 0.0-1 MAIN DISCONNECT


LOCKED AND TAGGED

1.0 DESCRIPTION
1.1 PURPOSE

The purpose of this manual is to provide information


on the unique features of the Low Ambient Option.
Aspects of performance and cold weather operation
are covered in the Sierra Operators Manual Form
88155494 (50-100 HP / 37-75 KW) or 39929104 (125-
200 HP / 90-300 KW). This manual supplements,
rather than replaces the Operators Manual; therefore,
both must be used.

1.2 TOOLS REQUIRED:

Only what would be found in any reasonably equipped


servicemans tool box.

2
1.3 GENERAL INFORMATION Table 1
120 Volt 60 Hertz 1 Phase (50-400 HP)
The Ingersoll-Rand low ambient system allows the
compressor to be operated in ambient temperatures Frame Size Space Heater
as low as 10F (-23.3C). The compressor is supplied Wattage
with space heaters in all motors and starter enclo-
320 90
sures. All control lines are heat traced and insulated.
360 119
There are minor operational changes that will be cov-
400 160
ered later in this manual.
440 242*
5000 400
*Note: Medium Voltage (4160 V) 440 frame size motors hav 400W space
heaters

2.0 SPACE HEATERS AND Table 2


HEAT TRACING 110 Volt and 220 Volt 50 Hertz 1 Phase (37-300 KW)

Space heaters have been provided in the motors and Frame Size Number of Poles Space Heater
starter box to help prevent formation of condensation. Wattage
These heaters are not intended to keep the motor or 200-225 2-4-6-8 2 x 25
starter enclosure temperature above freezing. The 250 2 2 x 25
space heaters keep condensation to a minimum, by 4-6-8 2 x 40
maintaining an approximate temperature 10F (5.6C) 280-315 2 2 x 40
above the ambient temperature. 4-6-8 2 x 50
355 2-4-6-8 150

! WARNING The starter space heater is a small strip heater mount-


ed directly to the starter back panel. The wattage rat-
ing is 125 watts for use on 115 volt 50/60 hertz 1
phase power and 120 watts on 220 volts/50 hertz, 1
phase power.

Both the motor space heaters and starter enclosure


space heater are wired through a normally closed aux-
iliary contact on the starter to de-energize the heaters
Hazardous voltage. Can cause when the compressor is running. There is also a
severe injury or death.
heater thermostat which senses ambient temperature
Disconnect power before servicing. to turn off all heaters when the temperature is above
Lockout/Tagout machine. 40F (4.4C). All heater leads are prewired to a termi-
nal block (TB4) located in the upper left hand corner of
INGERSOLLrAND 39540174
the starter box. This terminal block requires a 115-1-
50/60 or 220-1-50 supply to be wired to terminals 1
and 6. The total system wattage varies with the size of
the main drive motor. See the chart below for maxi-
mum wattage requirements.

Table 3
120 Volt 60 Hertz 1 Phase (50-400 HP)

Frame Size Maximum Total


Heater Wattage

320 992
92930593
360 1021
400 1062
440 1219
The wattage rating of motor space heaters varies with 5000 1377
the frame size of the motor. See chart for ratings.

3
Table 4 4.0 GENERAL OPERATION
110 Volt and 220 Volt 50 Hertz 1 Phase (37-300KW)
Operation of the compressor is per the standard oper-
Frame Size Maximum Total ators manual except for the following. The intake lou-
Heater Wattage vers will open and close to prevent the unit from over
cooling. Heat tracing and heaters will turn off and on
200-225 943 according to compressor and ambient temperature.
250 1048
280-315 1093
355 1143 4.1 MAINTENANCE
NOTE: THE CUSTOMER MUST SUPPLY 115-1-50/60 Both the damper motor and the louvers are perma-
OR 220-1-50 POWER TO THIS TERMINAL BLOCK. nently lubricated and normally do not require mainte-
nance. Louvers should be checked periodically for
Moisture separators, condensate drains and all control proper operation.
lines are provided with heat tracing (5 watts/ft). The oil
sump has a heater (500W) installed to maintain mini-
mum oil temperature. All heat tracing is insulated with 4.2 ADJUSTMENT
1/2 foam to ensure that the heat stays where it is
needed. The heat tracing and sump heater are factory BEFORE ATTEMPTING ANY SERVICE WORK,
wired and are either on or off as determined by the OPEN MAIN DISCONNECT, LOCK AND TAG.
ambient thermostat referred to earlier. In addition, the
heat tracing is of the self limiting type which increases All thermostats are factory adjusted to the tempera-
the heat generated according to the temperature of the tures listed below.
tube being heated.
1. Ambient Heater Thermostat 40F (4.4C).
For actual wiring schematic and connection points 2. Damper Motor Thermostat 55F (12.8C). (See
refer to the decal located on the inside of the starter Figure 4.2-1)
box door.
The ambient and damper motor thermostats can be
adjusted by simply turning the calibrated dial either
clockwise or counterclockwise to raise or lower the set
3.0 AIR FLOW MODULATION point.
A thermostat with a variable setting senses the tem- The louvers are shipped with the linkages properly
perature at the cooling air intake. This thermostat mod- adjusted. However, due to possible disturbances dur-
ulates the intake louvers to prevent the compressor ing shipping and handling, or as a result of service
heat exchangers from over cooling. The thermostat work, the linkage may need to be readjusted.
and the damper motor are factory wired. When the
cooling air temperature is below 55F (12.8C). the
damper motor will begin to move, closing the main 4.3 LOUVER SETTINGS
intake (large) louver, while simultaneously opening the
recirculation (small) louver. The warmer air from the With power disconnected, the main intake louver
upper plenum is mixed into the cooling air, maintaining should be in an open position (70 from vertical) and
proper cooling air temperature. the recirculating louver should be fully closed.

When the cooling air inlet temperature is below the


thermostats setpoint, both louvers will modulate. The
main intake louver should modulate between 70and
5 from vertical while simultaneously the recirculating
louver moves from closed to 60 open.

4
4.4 LOUVER OPERATION

- The louvers should move freely with no binding.

- The motor must be permitted to complete its full


stroke. If the louver closes before the motor has
stopped, the motor can be permanently damaged.

- When the recirculating louver is in the closed posi-


tion, a relative tight seal is required to prevent warm air
from entering the inlet when it is not needed.

Louvers may be adjusted by loosening the ball joints


and moving the drive rods to the required position
(See Figure 4.4-1).

NOTICE:
ALL LOUVER LINKAGES ARE FACTORY ADJUST-
ED. ANY ADJUSTMENTS SHOULD BE PER-
FORMED BY A CERTIFIED INGERSOLL-RAND
SERVICE TECHNICIAN.

! WARNING

Moving parts.
Can cause severe injury.

Do not operate with covers removed.


Service only with machine blocked to
prevent turn over.

INGERSOLLrAND 39540224

! 92930627

5
5.0 PROCESS AND INSTRUMENTATION
DIAGRAMS
54448733
REV A
5.1 50-100 HP (37-75 KW)
6
LEGEND

ABBREV DESCRIPTION ABBREV DESCRIPTION

S1 1ST COMPRESSOR STAGE 1MS INTERSTAGE MOISTURE SEPARATOR


S2 2ND COMPRESSOR STAGE 2MS DISCHARGE MOISTURE SEPARATOR
GC GEARCASE 1MCV INTERSTAGE MANUAL CONDENSATE VALVE
SU SUMP 2MCV DISCHARGE MANUAL CONDENSATE VALVE
SH SUMP HEATER 1SSV INTERSTAGE STRAINER SERVICE VALVE
AC AFTERCOOLER 2SSV DISCHARGE STRAINER SERVICE VALVE
AF AIR FILTER 1CS INTERSTAGE CONDENSATE STRAINER
BFV BUTTERFLY THROTTLE VALVE 2CS DISCHARGE CONDENSATE STRAINER
HC HYDRAULIC CYLINDER CCV CONDENSATE CHECK VALVE
IC INTERCOOLER 1SV LOAD SOLENOID VALVE
CA COMPRESSED AIR 6SV INTERSTAGE CONDENSATE SOLENOID VALVE
OC OIL COOLER 9SV DISCHARGE CONDENSATE SOLENOID VALVE
1OM OIL MANIFOLD 1AVPG VACUUM PRESSURE GAUGE
2OM OIL MANIFOLD 1APG 2ND STAGE INLET PRESSURE GAUGE (OPTIONAL)
3OM OIL MANIFOLD 5OPG BEARING OIL PRESSURE GAUGE (OPTIONAL)
OF OIL FILTER 4APT AIR PRESSURE TRANSDUCER RANGE: 0 TO 200 PSI
OTCV OIL TEMP CONTROL VALVE 2ATT AIR TEMPERATURE TRANSDUCER (RTD) RANGE: - 18 TO 266 C
OP OIL PUMP 3ATT AIR TEMPERATURE TRANSDUCER (THERMISTER) RANGE: -18 TO 120 C
ODV OIL DRAIN VALVE 4ATT AIR TEMPERATURE TRANSDUCER (RTD) RANGE: -18 TO 266 C
OS OIL STRAINER 7ATT AIR TEMPERATURE TRANSDUCER (THERMISTER) RANGE: -18 TO 120 C
C CONDENSATE 5OTT OIL TEMPERATURE TRANSDUCER (THERMISTER) RANGE: -18 TO 120 C
1OR BLOWDOWN ORIFICE 3APS 2ND STAGE DISCHARGE PRESSURE SWITCH
2OR OIL FLOW ORIFICE 5OPS BEARING OIL PRESSURE SWITCH
BR BREATHER
BDV BLOWDOWN VALVE
DCV DISCHARGE CHECK VALVE
1DS 1ST STAGE DISCHARGE SILENCER
2DS 2ND STAGE DISCHARGE SILENCER
3DS BLOWDOWN DISCHARGE SILENCER
4DS BLOWDOWN DIFFUSER
1EJ INTERSTAGE EXPANSION JOINT
1RV INTERSTAGE SAFETY RELIEF VALVE
2RV DISCHARGE SAFETY RELIEF VALVE
3RV OIL PRESSURE RELIEF VALVE
7
39912001
REV 02
5.2 125-200 HP (90-150 KW)
8
LEGEND

ABBREV DESCRIPTION ABBREV DESCRIPTION

S1 1ST COMPRESSOR STAGE 1MCV INTERSTAGE MANUAL CONDENSATE VALVE


S2 2ND COMPRESSOR STAGE 2MCV DISCHARGE MANUAL CONDENSATE VALVE
GC GEARCASE 1SSV INTERSTAGE STRAINER SERVICE VALVE
SU SUMP 2SSV DISCHARGE STRAINER SERVICE VALVE
SH SUMP HEATER - 500 W 1CS INTERSTAGE CONDENSATE STRAINER
AF AIR FILTER 2CS DISCHARGE CONDENSATE STRAINER
AC AFTERCOOLER CCV CONDENSATE CHECK VALVE
BFV BUTTERFLY THROTTLE VALVE CLS CONDENSATE LEVEL SWITCH (OPTIONAL)
HC HYDRAULIC CYLINDER 1SV LOAD SOLENOID VALVE
IC INTERCOOLER 6SV INTERSTAGE CONDENSATE SOLENOID VALVE
OC OIL COOLER 9SV DISCHARGE CONDENSATE SOLENOID VALVE
OM OIL MANIFOLD 1AVPT VACUUM PRESSURE TRANSDUCER RANGE: 0 TO 15 PSI
OF OIL FILTER 2APT AIR PRESSURE TRANSDUCER RANGE: 0 TO 100 PSI
OTCV OIL TEMP CONTROL VALVE 3APT AIR PRESSURE TRANSDUCER RANGE: 0 TO 200 PSI
OP OIL PUMP 4APT AIR PRESSURE TRANSDUCER RANGE: 0 TO 200 PSI
ODV OIL DRAIN VALVE 5OPT OIL PRESSURE TRANSDUCER RANGE: 0 TO 200 PSI
OS OIL STRAINER 6OPT OIL PRESSURE TRANSDUCER RANGE: 0 TO 200 PSI
1OR BLOWDOWN ORIFICE 2ATT AIR TEMPERATURE TRANSDUCER (RTD) RANGE: -18 TO 266 C
2OR OIL FLOW ORIFICE 3ATT AIR TEMPERATURE TRANSDUCER (THERMISTER) RANGE: -18 TO 120 C
BR BREATHER 4ATT AIR TEMPERATURE TRANSDUCER (RTD) RANGE: -18 TO 266 C
BDV BLOWDOWN VALVE 7ATT AIR TEMPERATURE TRANSDUCER (THERMISTER) RANGE: -18 TO 120 C
DCV DISCHARGE CHECK VALVE 5OTT OIL TEMPERATURE TRANSDUCER (THERMISTER) RANGE: -18 TO 120 C
CA COMPRESSED AIR
C CONDENSATE
1DS IST STAGE DISCHARGE SILENCER
2DS 2ND STAGE DISCHARGE SILENCER
3DS BLOWDOWN DISCHARGE SILENCER
1EJ INTERSTAGE EXPANSION JOINT
2EJ FIRST STAGE EXPANSION JOINT
3EJ DISCHARGE EXPANSION JOINT
4EJ SECOND STAGE EXPANSION JOINT
1RV INTERSTAGE SAFETY RELIEF VALVE- SET 45 PSIG
2RV DISCHARGE SAFETY RELIEF VALVE - SET 165 PSIG
3RV OIL PRESSURE RELIEF VALVE - SETTING FACTORY ADJUSTED TO
MAINTAIN 40-45 PSI HOT OIL PRESSURE.
1MS INTERSTAGE MOISTURE SEPARATOR
9

2MS DISCHARGE MOISTURE SEPARATOR


54538889
REV A
5.3 250-400 HP (200-300 KW)
10
LEGEND

ABBREV. DESCRIPTION ABBREV. DESCRIPTION

S1 FIRST COMPRESSOR STAGE 6SV INTERSTAGE CONDENSATE SOLENOID VALVE


S2 SECOND COMPRESSOR STAGE 9SV DISCHARGE CONDENSATE SOLENOID VALVE
GC GEARCASE SSH SUMP HEATER - 500 W
SU SUMP 1AVPT VACUUM PRESSURE TRANSDUCER 0-15 PSI
AF AIR FILTER 2APT AIR PRESSURE TRANSDUCER 0-100 PSI
AC AFTERCOOLER 3APT AIR PRESSURE TRANSDUCER 0-225 PSI
BFV BUTTERFLY THROTTLE VALVE 4APT AIR PRESSURE TRANSDUCER 0-225 PSI
HC HYDRAULIC CYLINDER 5OPT OIL PRESSURE TRANSDUCER 0-100 PSI
IC INTERCOOLER 6OPT OIL PRESSURE TRANSDUCER 0-100 PSI
OC OIL COOLER 2ATT AIR TEMPERATURE TRANSDUCER (RTD) -18 TO 266 C
OM OIL MANIFOLD 3ATT AIR TEMPERATURE TRANSDUCER (THERMISTOR) -18 TO 120 C
OF OIL FILTER 4ATT AIR TEMPERATURE TRANSDUCER (RTD) -18 TO 266 C
OTCV OIL TEMPERATURE CONTROL VALVE 7ATT AIR TEMPERATURE TRANSDUCER (THERMISTOR) -18 TO 120 C
OP OIL PUMP 5OTT OIL TEMPERATURE TRANSDUCER (THERMISTOR) -18 TO 120 C
ODV OIL DRAIN VALVE
OS OIL STRAINER
1OR OIL FLOW ORIFICE
BR BREATHER
BDV BLOWDOWN VALVE
DCV DISCHARGE CHECK VALVE
CA COMPRESSED AIR
C CONDENSATE
1DS FIRST STAGE DISCHARGE SILENCER
2DS SECOND STAGE DISCHARGE SILENCER
3DS BLOWDOWN DISCHARGE SILENCER
1EJ INTERSTAGE EXPANSION JOINT
2EJ SECOND STAGE EXPANSION JOINT
3EJ DISCHARGE EXPANSION JOINT
1RV INTERSTAGE SAFETY RELIEF VALVE
2RV DISCHARGE SAFETY RELIEF VALVE
3RV OIL PRESSURE RELIEF VALVE
1MS INTERSTAGE MOISTURE SEPARATOR
2MS DISCHARGE MOISTURE SEPARATOR
CLS CONDENSATE LEVEL SWITCH (OPTIONAL)
11

1SV LOAD SOLENOID VALVE


6.0 WIRING SCHEMATICS 39911979
REV 02
6.1 110V-1PH-50 HZ AND 120V-1PH-60 HZ
12
LEGEND
ABBREV DESCRIPTION

1MD COMPRESSOR STARTER AUXILIARY CONTACT


4TB TERMINAL STRIP
DMSH DRIVE MOTOR SPACE HEATER
FMSH FAN MOTOR SPACE HEATER
SSH STARTER SPACE HEATER
3ATS AMBIENT THERMOSTAT (SET TO CLOSE AT 4 C (40 F)
ON DECREASE IN TEMPERATURE)
CLH1 CONTROL LINE SPACE HEATER 4APT
CLH2 CONTROL LINE SPACE HEATER 3APT
OSH1 OIL SUMP HEATER
T4 DAMPER MOTOR TRANSFORMER
1DM DAMPER MOTOR
1DT DAMPER PROPORTIONING THERMOSTAT
DIS DISCONNECT (CUSTOMER SUPPLIED)

NOTES:

1. MAIN DISCONNECT AND BRANCH CIRCUIT PROTECTION TO BE PROVIDED BY


CUSTOMER.

2. DASHED LINES REPRESENT WIRING BY CUSTOMER.

3. SIZING OF ELECTRICAL COMPONENTS, NOT SUPPLIED BY


INGERSOLL-RAND, IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD
BE DONE IN ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR DATA
PLATE, NATIONAL AND LOCAL ELECTRICAL CODES.

4. CUSTOMER IS RESPONSIBLE FOR SUPPLYING POWER TO THE SPACE HEATER


CIRCUIT.

5. SEE TABLES 1 THRU 4 FOR HEATER WATTAGES.


13
39927488
REV B
6.2 220V-1PH-50 HZ AND 240V-1PH-60 HZ
14
LEGEND

ABBREV DESCRIPTION

1MD COMPRESSOR STARTER AUXILIARY CONTACT


4TB TERMINAL STRIP
DMSH DRIVE MOTOR SPACE HEATER
FMSH FAN MOTOR SPACE HEATER
SSH STARTER SPACE HEATER
3ATS AMBIENT THERMOSTAT (SET TO CLOSE AT 4 C (40 F)
ON DECREASE IN TEMPERATURE)
CLH1 CONTROL LINE SPACE HEATER 4APT
CLH2 CONTROL LINE SPACE HEATER 3APT
OSH1 OIL SUMP HEATER
T4 DAMPER MOTOR TRANSFORMER
1DM DAMPER MOTOR
1DT DAMPER PROPORTIONING THERMOSTAT
DIS DISCONNECT (CUSTOMER SUPPLIED)

NOTES:

1. MAIN DISCONNECT AND BRANCH CIRCUIT PROTECTION TO BE PROVIDED BY


CUSTOMER.

2. DASHED LINES REPRESENT WIRING BY CUSTOMER.

3. SIZING OF ELECTRICAL COMPONENTS, NOT SUPPLIED BY


INGERSOLL-RAND, IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD
BE DONE IN ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR DATA
PLATE, NATIONAL AND LOCAL ELECTRICAL CODES.

4. CUSTOMER IS RESPONSIBLE FOR SUPPLYING POWER TO THE SPACE HEATER


CIRCUIT.

5. SEE TABLES 1 THRU 4 FOR HEATER WATTAGES.


15
7.0 FOUNDATION
PLANS
39909809
REV 02
7.1 50-100 HP (CONTINUED)
16
39909809
REV 02
7.1 50-100 HP (CONTINUED)
17
18

7.1 50-100 HP NOTES: KEY

1. WEIGHTS APPROXIMATE: A STARTER BOX DOOR CLEARANCE AREA. SEE NOTE 7.


50-100 HP ( ODP): 2318 - 2597 KG ( 5151 - 577 1 LBS) B COOLING AIR EXHAUST.
100 HP ( TEFC): 2577 - 2677 KG ( 5727 - 5949 LBS) C AIR INTAKE.
2. COOLING AIR FLOW : 227M3/MIN - 8000 CFM. D STARTER BOX.
3. PIPE CONDENSATE DRAIN LINES SEPARATELY TO AN OPEN DRAIN DUE TO E COMPRESSOR AIR INTAKE.
DIFFERENCES IN DRAIN PRESSURES. F 1.00 INCH NPT MALE BREATHER PIPING CONNECTION.
4. LUBE OIL FILL QUANTITY: 42 LITERS (11 GALLONS) APPROXIMATELY. SEE NOTE 11.
5. ALL DIMENSIONS IN MILLIMETERS (IN). G 1.50 INCH NPT FEMALE AIR DISCHARGE CONNECTION.
6. TOLERANCE ON ALL DIMENSIONS: 6 MM ( .25 INCH) H .25 INCH NPT AFTERCOOLER CONDENSATE DRAIN.
7. RECOMMENDED CLEARANCE ON THREE SIDES 914 (36.00). J .25 INCH NPT INTERCOOLER CONDENSATE DRAIN.
1067 (42.00) FRONT OF CONTROL PANEL OR MINIMUM AS REQUIRED BY K .50 INCH NPT FEMALE AFTERCOOLER CONDENSATE DRAIN.
LATEST NATIONAL ELECTRICAL CODE OR APPLICABLE LOCAL CODES. L .50 INCH NPT FEMALE INTERCOOLER CONDENSATE DRAIN.
8. EXTERNAL PIPING SHALL NOT EXERT ANY UNRESOLVED MOMENTS OR M SEAL VENT OPENING. DO NOT PLUG.
FORCES ON UNIT. USE PIPE SIZE AS LARGE OR LARGER AT DIS- N .25 NPT FEMALE SHAFT SEAL DRAIN. DO NOT PLUG.
CHARGE LOCATION. S FORK LIFT OPENINGS. SEE NOTE 10.
9. THERE SHOULD BE NO PLASTIC OR PVC PIPING ATTACHED TO THIS UNIT T POWER INLET LOCATION FOR CONDUIT. SEE NOTE 16.
OR USED FOR ANY LINES DOWNSTREAM.
10. FORKLIFT HOLE COVERS MUST BE INSTALLED AFTER UNIT IS IN PLACE
TO REDUCE NOISE AND ENSURE PROPER COOLING OF PACKAGE.
11. FIELD INSTALLED DUCTING TO AND FROM COMPRESSOR CANNOT ADD
MORE THAN 6 MM (0.25 INCHES) OF WATER TOTAL AIR RESISTANCE.
GEAR BOX BREATHER MUST BE PIPED EXTERNAL.
12. UNIT HAS INTERNAL DISCHARGE CHECK VALVE. EXTERNAL CHECK VALVE
NOT REQUIRED. ISOLATION VALVE 15 RECOMMENDED.
13. COMPRESSOR SHOULD BE BOLTED TO THE FLOOR WITH FOUR 19
MM(.75) BOLTS, LOCATED IN THE BOTTOM VIEW ON THE
PRECEDING PAGE, WITH IT BEING SEALED WITH CORK OR RUBBER.
14. DO NOT PIPE INTO A COMMON HEADER WITH A RECIPROCATING COM-
PRESSOR. UNLESS RECIP COMPRESSOR UTILIZES A DISCHARGE PUL-
SATION DAMPENER.
15. DENOTES CENTER OF GRAVITY.
16. SIZING OF ELECTRICAL COMPONENTS, NOT SUPPLIED BY INGERSOLL-
RAND, IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD BE
DONE IN ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR

39909809
DATA PLATE, NATIONAL AND LOCAL ELECTRICAL CODES.

REV 02
39909817
REV 02
7.2 37-75 KW (CONTINUED)
19
39909817
REV 02
7.2 37-75 KW (CONTINUED)
20
NOTES: KEY

1. WEIGHTS APPROXIMATE: A STARTER BOX DOOR CLEARANCE AREA. SEE NOTE 7.


50-100 HP (ODP) : 2318 - 2597 KG ( 5151 - 5771 LBS) B COOLING AIR EXHAUST.
100 HP (TEFC) : 2577 - 2677 KG ( 5727 - 5949 LBS) C AIR INTAKE.
2. COOLING AIR FLOW : 227M3/MIN - 8000 CFM. D STARTER BOX.
3. PIPE CONDENSATE DRAIN LINES SEPARATELY TO AN OPEN DRAIN DUE TO E COMPRESSOR AIR INTAKE.
DIFFERENCES IN DRAIN PRESSURES. F 1.00 BSPT MALE BREATHER PIPING CONNECTION.
4. LUBE OIL FILL QUANTITY: 42 LITERS (11 GALLONS) APPROXIMATELY. SEE NOTE 11.
5. ALL DIMENSIONS IN MILLIMETERS (IN). G 1.50 BSPT FEMALE AIR DISCHARGE CONNECTION.
6. TOLERANCE ON ALL DIMENSIONS: 6 MM ( .25 INCH H .25 BSPT AFTERCOOLER CONDENSATE DRAIN.
7. RECOMMENDED CLEARANCE ON THREE SIDES 914 (36.00). J .25 BSPT INTERCOOLER CONDENSATE DRAIN.
1067 (42.00) FRONT OF CONTROL PANEL OR MINIMUM AS REQUIRED BY K .50 BSPT FEMALE AFTERCOOLER CONDENSATE DRAIN.
LATEST NATIONAL ELECTRICAL CODE OR APPLICABLE LOCAL CODES. L .50 BSPT FEMALE INTERCOOLER CONDENSATE DRAIN.
8. EXTERNAL PIPING SHALL NOT EXERT ANY UNRESOLVED MOMENTS OR M SEAL VENT OPENING. DO NOT PLUG.
FORCES ON UNIT. USE PIPE SIZE AS LARGE OR LARGER AT DISCHARGE N .25 BSPT FEMALE SHAFT SEAL DRAIN. DO NOT PLUG.
LOCATION. P BASE DRAINS.
9. THERE SHOULD BE NO PLASTIC OR PVC PIPING ATTACHED TO THIS UNIT S FORK LIFT OPENINGS. SEE NOTE 10.
OR USED FOR ANY LINES DOWNSTREAM. T POWER INLET LOCATION FOR CONDUIT. SEE NOTE 16.
10. FORKLIFT HOLE COVERS MUST BE ENSTALLED AFTER UNIT IS IN PLACE
TO REDUCE NOISE AND ENSURE PROPER COOLING OF PACKAGE
11. FIELD INSTALLED DUCTING TO AND FROM COMPRESSOR CANNOT ADD
MORE THAN 6MM (0.25 INCHES) OF WATER TOTAL AIR RESISTANCE. GEAR BOX
BREATHER MUST BE PIPED EXTERNAL.
12. UNIT HAS INTERNAL DISCHARGE CHECK VALVE. EXTERNAL CHECK VALVE
NOT REQUIRED. ISOLATION VALVE IS RECOMMENDED.
13. COMPRESSOR SHOULD BE BOLTED TO THE FLOOR WITH FOUR 19 MM(.75)
BOLTS, LOCATED IN THE BOTTOM VIEW OF THE PRECEDING PAGE, WITH IT BEING
SEALED WITH CORK OR RUBBER.
14. DO NOT PIPE INTO A COMMON HEADER WITH A RECIPROCATING
COMPRESSOR. UNLESS RECIP COMPRESSOR UTILIZES A DISCHARGE
PULSATION DAMPENER.
15. DENOTES CENTER OF GRAVITY.
16. SIZING OF ELECTRICAL COMPONENTS, NOT SUPPLIED BY
INGERSOLL-RAND, IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD
BE DONE IN ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR

39909817
DATA PLATE, NATIONAL AND LOCAL ELECTRICAL CODES.

REV 02
7.2 37-75 KW
21
39907977
REV 02
7.3 125-200 HP (CONTINUED)
22
39907977
REV 02
7.3 125-200 HP (CONTINUED)
23
24

7.3 125-200 HP NOTES: KEY

1. WEIGHTS APPROXIMATE: A STARTER BOX DOOR CLEARANCE AREA. SEE NOTE 7.


125-150HP (ODP) : 2920 - 3050 KG (6437 - 6724 LBS) B COOLING AIR EXHAUST.
200HP (ODP) : 3220 - 3350 KG (7099 - 7385 LBS) C AIR INTAKE.
125-200HP (TEFC) : 3300 - 3400 KG (7275 - 7496 LBS) D STARTER BOX.
2. COOLING AIR FLOW : 425 M 3 /MIN - 15000 CFM. E 1.00 INCH NPT MALE BREATHER PIPING CONNECTION.
3. PIPE CONDENSATE DRAIN LINES SEPARATELY TO AN OPEN SEE NOTE 11.
DRAIN DUE TO DIFFERENCE IN DRAIN PRESSURES. F .50 INCH NPT FEMALE AFTERCOOLER CONDENSATE
4. LUBE OIL FILL QUANTITY: 45 LITERS (12 GALLONS) APPROXIMATELY. DRAIN.
5. ALL DIMENSIONS IN MILLIMETERS (IN). G .25 INCH NPT FEMALE AFTERCOOLER MANUAL
6. TOLERANCE ON ALL DIMENSIONS: 6 MM (.25 INCH). CONDENSATE DRAIN. (SHIPPED LOOSE)
7. RECOMMENDED CLEARANCE ON THREE SIDES 914 (36.00). H .25 INCH NPT FEMALE INTERCOOLER MANUAL
1067 (42.00) FRONT OF CONTROL PANEL OR MINIMUM AS REQUIRED CONDENSATE DRAIN. (SHIPPED LOOSE)
BY LATEST NATIONAL ELECTRICAL CODE OR APPLICABLE LOCAL J .50 INCH NPT FEMALE INTERCOOLER CONDENSATE
CODES. DRAIN.
8. EXTERNAL PIPING SHALL NOT EXERT ANY UNRESOLVED MOMENTS K SEAL VENT OPENING. DO NOT PLUG.
OR FORCES ON UNIT. USE PIPE SIZE AS LARGE OR LARGER AT DIS M FORK LIFT OPENINGS. SEE NOTE 10.
CHARGE LOCATION. N POWER INLET LOCATION FOR CONDUIT.
9. THERE SHOULD BE NO PLASTIC OR PVC PIPING ATTACHED TO THIS SEE NOTE 16.
UNIT OR USED FOR ANY LINES DOWNSTREAM. P 2.00 NPT FEMALE AIR DISCHARGE CONNECTION.
10. FORKLIFT HOLE COVERS MUST BE INSTALLED AFTER UNIT IS IN
PLACE TO REDUCE NOISE AND ENSURE PROPER COOLING OF
PACKAGE.
11. FIELD INSTALLED DUCTING TO AND FROM COMPRESSOR CANNOT
ADD MORE THAN 6 MM (0.25 INCHES) OF WATER TOTAL AIR
RESISTANCE. GEAR BOX BREATHER MUST BE PIPED EXTERNAL.
12. UNIT HAS INTERNAL DISCHARGE CHECK VALVE. EXTERNAL CHECK
VALVE NOT REQUIRED. ISOLATION VALVE IS RECOMMENDED.
13. COMPRESSOR SHOULD BE BOLTED TO THE FLOOR WITH FOUR 19
MM(.75) BOLTS, LOCATED IN THE BOTTOM VIEW OF THE PRECEDING
PAGE, WITH IT BEING SEALED WITH CORK OR RUBBER.
14. DO NOT PIPE INTO A COMMON HEADER WITH A RECIPROCATING
COMPRESSOR, UNLESS RECIP COMPRESSOR UTILIZES A DIS-
CHARGE PULSATION DAMPENER.
15. DENOTES CENTER OF GRAVITY.

39907977
16. SIZING OF ELECTRICAL COMPONENTS, NOT SUPPLIED BY

REV 02
INGERSOLL-RAND, IS THE RESPONSIBILITY OF THE CUSTOMER AND
SHOULD BE DONE IN ACCORDANCE WITH THE INFORMATION ON THE
COMPRESSOR DATA PLATE, NATIONAL AND LOCAL ELECTRICAL
CODES.
54609771
REV A
7.4 90-150 KW (CONTINUED)
25
54609771
REV A
7.4 90-150 KW (CONTINUED)
26
NOTES: KEY
1. WEIGHTS APPROXIMATE:
90-110KW ( ODP): 2920 - 3050 KG ( 6437 - 6724 LBS) A STARTER BOX DOOR CLEARANCE AREA. SEE NOTE 7.
132-150KW ( ODP): 3220 - 3350 KG ( 7099 - 7385 LBS) B COOLING AIR EXHAUST.
90-150KW ( TEFC): 3300 - 3400 KG ( 7275 - 7496 LBS) C AIR INTAKE.
D STARTER BOX.
2. COOLING AIR FLOW : 425 M3/MIN - 15000 CFM. E 1.00 INCH BSPT MALE BREATHER PIPING CONNECTION. SEE
3. PIPE CONDENSATE DRAIN LINES SEPARATELY TO AN OPEN DRAIN NOTE 11.
DUE TO DIFFERENCE IN DRAIN PRESSURES. F .50 INCH BSPT FEMALE AFTERCOOLER CONDENSATE
4. LUBE OIL FILL QUANTITY: 45 LITERS (12 GALLONS) APPROXIMATELY. DRAIN.
5. ALL DIMENSIONS IN MILLIMETERS (IN). G .25 INCH BSPT FEMALE AFTERCOOLER MANUAL CONDEN-
6. TOLERANCE ON ALL DIMENSIONS: 6 MM (.25 INCH). SATE DRAIN. (SHIPPED LOOSE)
7. RECOMMENDED CLEARANCE ON THREE SIDES 914 (36.00). H .25 INCH BSPT FEMALE INTERCOOLER MANUAL CONDEN-
1067 (42.00) FRONT OF CONTROL PANEL OR MINIMUM AS REQUIRED SATE DRAIN. (SHIPPED LOOSE)
BY LATEST NATIONAL ELECTRICAL CODE OR APPLICABLE LOCAL J .50 INCH BSPT FEMALE INTERCOOLER CONDENSATE DRAIN.
CODES. K SEAL VENT OPENING. DO NOT PLUG.
8. EXTERNAL PIPING SHALL NOT EXERT ANY UNRESOLVED MOMENTS M FORK LIFT OPENINGS. SEE NOTE 10.
OR FORCES ON UNIT. USE PIPE SIZE AS LARGE OR LARGER AT N POWER INLET LOCATION FOR CONDUIT. SEE NOTE 16.
DISCHARGE LOCATION. P 2.00 BSPT FEMALE AIR DISCHARGE CONNECTION.
9. THERE SHOULD BE NO PLASTIC OR PVC PIPING ATTACHED TO THIS
UNIT OR USED FOR ANY LINES DOWNSTREAM.
10. FORKLIFT HOLE COVERS MUST BE INSTALLED AFTER UNIT IS IN
PLACE TO REDUCE NOISE AND ENSURE PROPER COOLING OF
PACKAGE.
11. FIELD INSTALLED DUCTING TO AND FROM COMPRESSOR CANNOT
ADD MORE THAN 6 MM (0.25 INCHES) OF WATER TOTAL AIR
RESISTANCE. GEAR BOX BREATHER MUST BE PIPED EXTERNAL.
12. UNIT HAS INTERNAL DISCHARGE CHECK VALVE. EXTERNAL CHECK
VALVE NOT REQUIRED. ISOLATION VALVE IS RECOMMENDED.
13. COMPRESSOR SHOULD BE BOLTED TO THE FLOOR WITH FOUR 19
MM(.75) BOLTS, LOCATED IN THE BOTTOM VIEW OF PRECEDING
PAGE, WITH IT BEING SEALED WITH CORK OR RUBBER.
14. DO NOT PIPE INTO A COMMON HEADER WITH A RECIPROCATING

54609771
COMPRESSOR. UNLESS RECIP COMPRESSOR UTILIZES A
7.4 90-150 KW

REV A
DISCHARGE PULSATION DAMPENER.
15. DENOTES CENTER OF GRAVITY.
16. SIZING OF ELECTRICAL COMPONENTS, NOT SUPPLIED BY
INGERSOLL-RAND, IS THE RESPONSIBILITY OF THE CUSTOMER AND
27

SHOULD BE DONE IN ACCORDANCE WITH THE INFORMATION ON THE


COMPRESSOR DATA PLATE, NATIONAL AND LOCAL ELECTRICAL
CODES.
54460977
REV A
7.5 250-400 HP (CONTINUED)
28
5446097
REV A
7.5 250-400 HP (CONTINUED)
29
5446097
REV A
7.5 250-400 HP
30
54542550
REV A
7.6 200-300 KW (CONTINUED)
31
54542550
REV A
7.6 200-300 KW (CONTINUED)
32
54542550
REV A
7.6 200-300 KW
33
8.0 ASSEMBLY DRAWINGS
39899877
REV 02
34
8.1 STANDARD SHEET METAL ASSEMBLY 50-100 HP (37-75 KW)

REF. REF.
NO. PART NO. QTY. DESCRIPTION NO. PART NO. QTY. DESCRIPTION

1 39898358 2 SUPPORT, LOW AMBIENT BOX 17 39429725 1 PUSHROD, 36.00 LENGTH (CUT TO SUIT)
1A 39133145 6 SCREW 18 39491501 1 MOTOR, MODULATING LOUVER
2 39898366 1 PANEL, LEFT END BOTTOM 18A 39131145 4 SCREW
2A 39133145 13 SCREW 18B 39189071 1 COVER, TRANSFORMER
3 39898374 1 PANEL, LEFT END FRONT 19 39136759 1 CRANK ARM, MODULATING LOUVER
3A 39133145 5 SCREW MOTOR
4 39871538 1 SUPPORT, MODULATING LOUVER 20 39140041 1 PUSHROD, 48.00 LENGTH (CUT TO SUIT)
MOTOR 21 39581905 1 EXTENSION, CRANK ARM
4A 39113145 4 SCREW 21A 39128426 2 BOLT
5 39898408 1 PANEL, LEFT END SIDE 21B 39128541 2 NUT
6 39867890 1 LOUVER, MODULATING 22 39311303 1 EXTENSION, LOUVER OPERATING ARM
6A 39133145 26 SCREW 22A 39128426 2 BOLT
7 39898416 1 BOX, LEFT END EXHAUST 228 39128541 2 NUT
7A 39133145 16 SCREW REF 39117312 1000 WEATHER STRIP (QUANTITY IS IN INCHES)
8 39587522 1 COVER, LOUVER ACCESS
8A 39133145 4 SCREW NOTE: STANDARD FASTENERS SUCH AS NUTS. BOLTS AND
9 39898432 1 PANEL, LEFT END REAR SCREWS ARE LISTED AS SUB-ITEMS (EXAMPLE 1A)
9A 39133145 5 SCREW
10 39898440 1 COVER, MODULATING LOUVER MOTOR
ACCESS
10A 39133145 6 SCREW
11 39868476 1 LOUVER, MODULATING
11A 39133145 14 SCREW
12 39898457 1 BOX, LEFT END TOP
12A 39133145 3 SCREW
13 39898465 1 PANEL, TOP EXHAUST
13A 39853940 1 FOAM, TOP PANEL (SIDE)
13B 39853957 1 FOAM, TOP PANEL (TOP)
13C 39133145 11 SCREW
14 39853569 1 LOUVER, EXHAUST
14A 39131145 8 SCREW
15 39898515 1 BOX, EXHAUST FRAME
15A 39900196 2 FOAM, EXHAUST FRAME
15B 39853924 1 FOAM, EXHAUST FRAME (SIDE)
35

15C 39133145 9 SCREW


16 39136783 4 BALL JOINT
36

39899877
8.1 RENTAL UNIT SHEET METAL ASSEMBLY 50-100 HP (37-75 KW) REV 02

REF REF
NO. PART NO. QTY. DESCRIPTION NO. PART NO. QTY. DESCRIPTION

1 39898358 2 SUPPORT, LOW AMBIENT BOX 14 39853569 1 LOUVER. EXHAUST


1A 39133145 6 SCREW 14A 39133145 8 SCREW
2 39258025 1 PANEL, LEFT END BOTTOM 15 39257936 1 BOX, EXHAUST FRAME
2A 39133145 13 SCREW 15A 39900196 2 FOAM, EXHAUST FRAME
3 39258017 1 PANEL, LEFT END FRONT 15B 39853924 1 FOAM, EXHAUST FRAME (SIDE)
3A 39133145 5 SCREW 15C 39133145 9 SCREW
4 39871538 1 SUPPORT, MODULATING LOUVER 16 39136783 4 BALL JOINT
MOTOR 17 39429725 1 PUSHROD, 36.00 LENGTH (CUT
4A 39133145 4 SCREW TO SUIT)
5 39258009 1 PANEL, LEFT END SIDE 18 39491501 1 MOTOR, MODULATING LOUVER
6 39867890 1 LOUVER, MODULATING 18A 39133145 4 SCREW
6A 39133145 26 SCREW 18B 39189071 1 COVER, TRANSFORMER
7 39257969 1 BOX, LEFT END EXHAUST 19 39136759 1 CRANK ARM, MODULATING
7A 39133145 16 SCREW LOUVER MOTOR
8 39257977 1 COVER, LOUVER ACCESS 20 39140041 1 PUSHROD, 48.00 LENGTH (CUT
8A 39133145 4 SCREW TO SUIT)
9 39257985 1 PANEL, LEFT END REAR 21 39581905 1 EXTENSION, CRANK ARM
9A 39133145 5 SCREW 21A 39128426 2 BOLT
10 39257993 1 COVER, MODULATING LOUVER 21B 39128541 2 NUT
MOTOR ACCESS 22 39311303 1 EXTENSION, LOUVER
10A 39133145 6 SCREW OPERATING ARM
11 39868476 1 LOUVER, MODULATING 22A 39128426 2 BOLT
11A 39133145 14 SCREW 22B 39128541 2 NUT
12 39257951 1 BOX, LEFT END TOP REF 39117312 1000 WEATHER STRIP
12A 39133145 3 SCREW (QUANTITY IS IN INCHES)
13 39257944 1 PANEL, TOP EXHAUST
13A 39853940 1 FOAM, TOP PANEL (SIDE) NOTE: STANDARD FASTENERS SUCH AS NUTS. BOLTS AND
13B 39853957 1 FOAM, TOP PANEL (TOP) SCREWS ARE LISTED AS SUB-ITEMS (EXAMPLE 1A)
13C 39133145 11 SCREW
NOTES:

37
39898861
REV 03
38
8.2 SHEET METAL ASSEMBLY 125-200 HP (90-150 KW)

REF
NO. PART NO. QTY. DESCRIPTION

1 39898499 2 SUPPORT, LOW AMBIENT BOX


2 39898507 2 PANEL, END LOW AMBIENT
3 39898523 1 ANGLE, FRONT LOW AMBIENT
4 39898531 2 PANEL, LOW AMBIENT
5 39848932 1 LOUVER,MODULATING
6 39898549 1 ANGLE, REAR LOW AMBIENT
7 39848940 1 LOUVER, MODULATING 36.50 X 19.50
8 39882899 1 ANGLE, LOW AMBMIENT PLENUM SEAL
9 39849237 1 SUPPORT, LOW AMBIENT MODULATING MOTOR
10 39491501 1 MOTOR , 50-450 HP MODULATING DAMPER
10A 39189071 1 COVER, TRANSFORMER
11 39136759 1 CRANK ARM, MOTOR
12 39569595 1 EXTENSION, CRANK ARM
13 39136793 4 BALL, JOINT
14 39140041 1 PUSH, ROD (CUT TO LENGTH REQUIRED AT ASSEMBLY)

HARDWARE NOT SHOWN


39133145 100 SCREW, SLF THRD W/PL. WASHER
39133152 25 SCREW, SLF THRD W/PL. WASHER
39128541 28 NUT, WHIZ-LOCK .25-20
39128434 8 SCREW, WHIZ-LOCK .25 X 1.00
39128426 20 SCREW, WHIZ-LOCK .250 X .625
39
54462155
REV A

8.3 SHEET METAL ASSEMBLY 250-450 HP (200-300 KW)

40
54462155
REV A

Item CCN Qty. Description Item CCN Qty. Description

18 54383435 2 FOAM
1 39924931 2 ANGLE 19 39136783 4 JOINT
2 39924998 1 ANGLE 20 39924857 1 LOUVER
3 54383369 1 ANGLE 21 39924865 1 LOUVER
4 54386651 1 ANGLE 22 39925102 1 LOUVER
5 39136759 2 ARM 23 39925144 1 LOUVER
6 54383393 1 CHANNEL 24 39491501 1 MOTOR
7 39924832 1 CORNER 25 39924881 1 ANGLE
8 39924840 2 CORNER 26 39916440 1 PANEL
9 39924873 1 CORNER 27 39924899 1 PANEL
10 39925110 1 CORNER 28 39924907 1 PANEL
11 39925128 2 CORNER 29 39924915 2 PANEL
12 39925151 1 CORNER 30 39924923 1 PANEL
13 39924956 1 COVER 31 54383385 2 PANEL
14 39924964 1 COVER 32 39429725 2 PUSHROD
15 39925003 1 COVER
16 39925011 1 COVER
17 54383419 1 FOAM

41
9.0 SPARE PARTS LIST

120V / 60 Hz
Part Description P/N Qty

Heater, Sump 39828348 1


Thermostat, Amb. Setting 39482898 1
Thermostat, Louver Control 39483177 1
Ball Joint 39136783 4
Transformer 39189071 1
Damper Motor
Gasket, Sump Heater Flange 39497904 1
Strip, Heater (125 W) 39128343 1
Motor, Damper 39491501 1
Controller, Mod. Motor 39483177 1
Decal, Wiring Schematic - Low 39911979 1
Ambient

110V / 50Hz
Part Description P/N Qty

Heater, Sump 39828348 1


Thermostat, Amb. Setting 39482898 1
Ball Joint 39136783 4
Transformer 39189071 1
Damper Motor
Gasket, Sump Heater Flange 39497904 1
Panel, Heater (120 W) 92905710 1
Motor, Damper 39491501 1
Controller, Mod. Motor 39483177 1
Decal, Wiring Schematic - Low 39911979 1
Ambient

220V / 50 Hz
Part Description P/N Qty

Heater, Sump 39872965 1


Thermostat, Amb. Setting 39482898 1
Ball Joint 39136783 4
Transformer 39245980 1
Damper Motor
Gasket, Sump Heater Flange 39497904 1
Panel, Heater (120 W) 92905710 1
Motor, Damper 39491501 1
Controller, Mod. Motor 39483177 1
Decal, Wiring Schematic - Low 39927488 1
Ambient

42